    SmartMarine 3D

    HVAC Labs

  • 8/8/2019 01 Sm3d Hvac Labs

    2/51

    CopyrightCopyright 2008 Intergraph Corporation. All Rights Reserved.

    Including software, file formats, and audiovisual displays; may be used pursuant to applicable software license

    agreement; contains confidential and proprietary information of Intergraph and/or third parties which is protected by

    copyright law, trade secret law, and international treaty, and may not be provided or otherwise made available

    without proper authorization.

    Restricted Rights Legend

    Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (c) of the

    Contractor Rights in Technical Data clause at DFARS 252.227-7013, subparagraph (b) of theRights in Computer

    Software or Computer Software Documentation clause at DFARS 252.227-7014, subparagraphs (b)(1) and (2) of

    theLicense clause at DFARS 252.227-7015, or subparagraphs (c) (1) and (2) ofCommercial Computer Software---

    Restricted Rights at 48 CFR 52.227-19, as applicable.

    Unpublished---rights reserved under the copyright laws of the United States.

    Intergraph Corporation

    Huntsville, Alabama 35894-0001

    Warranties and LiabilitiesAll warranties given by Intergraph Corporation about equipment or software are set forth in your purchase contract,

    and nothing stated in, or implied by, this document or its contents shall be considered or deemed a modification or

    amendment of such warranties. Intergraph believes the information in this publication is accurate as of its

    publication date.

    The information and the software discussed in this document are subject to change without notice and are subject to

    applicable technical product descriptions. Intergraph Corporation is not responsible for any error that may appear in

    this document.

    The software discussed in this document is furnished under a license and may be used or copied only in accordance

    with the terms of this license.

    No responsibility is assumed by Intergraph for the use or reliability of software on equipment that is not supplied by

    Intergraph or its affiliated companies. THE USER OF THE SOFTWARE IS EXPECTED TO MAKE THE FINALEVALUATION AS TO THE USEFULNESS OF THE SOFTWARE IN HIS OWN ENVIRONMENT.

    Trademarks

    Intergraph, the Intergraph logo, SmartSketch, FrameWorks, SmartPlant, INtools, MARIAN, and PDS are registered

    trademarks of Intergraph Corporation. Microsoft and Windows are registered trademarks of Microsoft Corporation.

    MicroStation is a registered trademark of Bentley Systems, Inc. ISOGEN is a registered trademark of Alias Limited.

    Other brands and product names are trademarks of their respective owners.

  • 8/8/2019 01 Sm3d Hvac Labs

    3/51

    HVAC Labs

    Preparation:

    1 Restore Training Plant2 Enter a Session File and set workspace to show ALL filter3 Activate pin point and set Active Coordinate system to Global4 Go to Edit, Paste from Catalog. Open Modules, HVAC, HV Grids5 Select HVAC_CS and ok6 OK on Place Macro7 Key in 0 for Easting, 0 for North and 0 for Elevation8

    Create a Filter that include U06

    9 Set your Workspace to Show U06 filter

  • 8/8/2019 01 Sm3d Hvac Labs

    4/51

    HVAC Labs

    LAB-1: Placing Air Handling Unit

    Objective1 Open a Session file with Imperial Units2 Define your Workspace to Show HVAC Labs filter3 If you are not in the Equipment task, then select Task -> Equipment and

    Furnishing

    4 Make sure the Active Permission Group is set to HVAC5 Activate PinPoint by Selecting Tools > PinPoint6 From Ribbon Bar, select more under Coordinate systems7 Expand HVAC, Grids and select HVAC_CS

  • 8/8/2019 01 Sm3d Hvac Labs

    5/51

    HVAC Labs

    8 Ok on the Select Coordinate System form9 Select Set target to Origin Option

    10 Select Place Designed Equipment Command11 From Catalog Browser select, \Equipment\Process\Horizontal Vessels\Horizontal

    Drum with Saddle

    12 On Properties page, change the name to AHU-0113 Change the System to A2\U06\HVAC\AHU14 Switch to Position and Orientation category15 Key in 31 for East, 4 for North and 2 for Elevation.16 Switch to Definition tab and make following changes

    17 OK on the properties page18 Select Place Shape Command

  • 8/8/2019 01 Sm3d Hvac Labs

    6/51

    HVAC Labs

    19 If prompted, select AHU-01 in WorkSpace Explorer20 Select the Rectangular shape21 Key in A=8, B=6 and C=422 Key in 31 for East, 4 for North and 2 for Elevation.23 Change the name of the shape to AHUBOX24 Select Place Nozzle Command and select the shape AHUBOX as the nozzle

    parent

    25 Change the port type to HVAC Port and set the properties as shown:

  • 8/8/2019 01 Sm3d Hvac Labs

    7/51

    HVAC Labs

    26 Switch to location tab and set the values as shown

    27 Place another Nozzle with following Properties

  • 8/8/2019 01 Sm3d Hvac Labs

    8/51

    HVAC Labs

  • 8/8/2019 01 Sm3d Hvac Labs

    9/51

    HVAC Labs

    Switch to Location tab and set

  • 8/8/2019 01 Sm3d Hvac Labs

    10/51

    HVAC Labs

    LAB-2: Basic Duct Routing

    1 Open a Session file with Imperial Units2 Define your Workspace to Show HVAC LABS filter3 Switch to HVAC task4 Activate PinPoint by Selecting Tools > PinPoint5 Select Route Duct command6 Select Port SP-01 on AHU-01 as the starting point7 Change the system as shown

  • 8/8/2019 01 Sm3d Hvac Labs

    11/51

    HVAC Labs

    8 Change the rest of the properties as shown

    9 System picks the Width and Depth from the Port.10 Route to Elevation 1611 Your view should resemble this

  • 8/8/2019 01 Sm3d Hvac Labs

    12/51

    HVAC Labs

  • 8/8/2019 01 Sm3d Hvac Labs

    13/51

    HVAC Labs

    LAB-3: Inserting Duct Divisions

    1 Select insert Inline Component Command2 Select the End Feature of Vertical Duct

    3

    Under Part, select more

    4 Select DivisionW2 as shown

  • 8/8/2019 01 Sm3d Hvac Labs

    14/51

    HVAC Labs

    5

    OK on the form

    6 Select the properties icon from the ribbon bar7 Change the properties as shown

    8 Select Finish to place the component

  • 8/8/2019 01 Sm3d Hvac Labs

    15/51

    HVAC Labs

    LAB-4: Inserting Transitions

    1 Select Insert Transition command2 Select the smaller section at the end of duct as shown

    3 On the new duct run form, keep the properties same as previous lab4 Change the size to 1 X 15 Change the length to 1 66 Finish placing the transition

  • 8/8/2019 01 Sm3d Hvac Labs

    16/51

    HVAC Labs

    LAB-5: Duct Routing with Bends and Branches

    1 Select Route Duct command2 Select the bigger end of the duct end

    3 Keep all the properties same as previous lab4 Change the angle to 90 in the ribbon bar5 Key in 20 for length6 Route the duct in North direction as shown

  • 8/8/2019 01 Sm3d Hvac Labs

    17/51

    HVAC Labs

    7 When finished, right click to cancel the command8 Place the target at the end of Duct placed in previous step9 Select Route Duct command10 Key in -10 for North and highlight the duct straight feature, left click to start the

    new run at this location

    11 Keep the same properties on new duct run form. Ok12 Change the size to 2 X 213 Route the duct west as shown

  • 8/8/2019 01 Sm3d Hvac Labs

    18/51

    HVAC Labs

  • 8/8/2019 01 Sm3d Hvac Labs

    19/51

    HVAC Labs

    LAB-6: Cardinal Point Routing

    1 Route Duct as shown using appropriate Cardinal pointNote: Make Sure you keep the plan plane lock on

    2 Right click to cancel the route command3 Select Route Duct command4 Define the end if transition as the starting point

  • 8/8/2019 01 Sm3d Hvac Labs

    20/51

    HVAC Labs

    5 Keep the same properties as above labs. Change the angle to 906 Route as shown

  • 8/8/2019 01 Sm3d Hvac Labs

    21/51

    HVAC Labs

    7 Select the Route Duct Command8 Start at the center 2 X 2 duct as shown

    9 Route North 4010 Place a Transition to 1 X 1, Length of transition 1 6 keeping Bottom and West

    Flat. Continue Routing from the Transition as Shown

  • 8/8/2019 01 Sm3d Hvac Labs

    22/51

    HVAC Labs

    11 Route a 1 6 X 1 6 Branch as shown

  • 8/8/2019 01 Sm3d Hvac Labs

    23/51

    HVAC Labs

    LAB-7: Placing Reducing Elbows

    1 Select Place Transition command2 Select the End Feature of Branch duct placed in previous step

    3 Change the type to turn

    4 Change the width and depth to 15 Change the Throat Radius to 16 Change the angle to 907 Point the elbow in North direction and click in the middle of elbow8 Finish to place the elbow9 Route 20 from elbow as shown

  • 8/8/2019 01 Sm3d Hvac Labs

    24/51

    HVAC Labs

  • 8/8/2019 01 Sm3d Hvac Labs

    25/51

    HVAC Labs

    LAB-8: Replacing Fittings

    1 Change locate filter to Duct Features2 Select the Duct along feature as shown

    3 Change the type to Rectangular Tee

  • 8/8/2019 01 Sm3d Hvac Labs

    26/51

    HVAC Labs

    4 Change the rest of the fittings as shown1: Miter Turn with number of miters 1

    2: HVAC Elbow

    3: HVAC SQUARE THROAT ELBOW

  • 8/8/2019 01 Sm3d Hvac Labs

    27/51

    HVAC Labs

    Note: When Routing, defaults for fittings can be set after defining Run properties and

    opening the properties page for run. (Select Route Duct. Click in the view, ok on the

    new duct run form, open the properties form. Select Defaults tab.)

  • 8/8/2019 01 Sm3d Hvac Labs

    28/51

    HVAC Labs

    LAB-9: Creating Diffusers/Gril ls/Registers

    Objective1 Open a Session file with Imperial Units2 Define your Workspace to Show HVAC Labs filter3 If you are not in the Equipment task, then select Task -> Equipment and

    Furnishing

    4 Make sure the Active Permission Group is set to HVAC5 Activate PinPoint by Selecting Tools > PinPoint6 From Ribbon Bar, select more under Coordinate systems7 Expand HVAC, Grids and select HVAC_CS8 Ok on the Select Coordinate System form9 Select Set target to Origin Command10 Select Place Designed Equipment Command11 From Catalog Browser select, \Equipment\Process\Horizontal Vessels\Horizontal

    Drum with Saddle

    12 Ok on the properties form13 Key in 20 for East, -20 for North and 0 for Elevation.14 Change the System to U06\HVAC\Supply\Devices15 Change the name to D24X24REC816 Select D24X24REC8 in WSE, and open its properties page17 Switch to Definition tab and make following changes

  • 8/8/2019 01 Sm3d Hvac Labs

    29/51

  • 8/8/2019 01 Sm3d Hvac Labs

    30/51

    HVAC Labs

    24 Change the name of shape to D-Box25 Select Place nozzle command26 Select the D-Box shape as the nozzle parent27 Select HVAC Port as the nozzle type28 Change the properties as shown

  • 8/8/2019 01 Sm3d Hvac Labs

    31/51

    HVAC Labs

    29 Switch to location tab

    30 The diffuser should resemble this

  • 8/8/2019 01 Sm3d Hvac Labs

    32/51

    HVAC Labs

    31 Select the diffuser D24X24REC832 Select Copy command. Click anywhere in view for reference point33 Select Paste command34 Accept the SP-Devices as parent folder35 Change the name of new diffuser to D24X24RND836 Open the property page for D24X24REC837 Switch to position and orientation category38 Change the east to 25 and OK39 Select Neck under D24X24REC8 and open its property page40 Change the cross section shape to Round41 Select the diffuser D24X24REC8

  • 8/8/2019 01 Sm3d Hvac Labs

    33/51

    HVAC Labs

    42 Select Copy command. Click anywhere in the view as reference form43 Select Paste command44 Change the parent system to RT-Devices, under Return system45 Change the name of new diffuser to G18X12REC12X846 Open the property page for G18X12REC12X847 Switch to position and orientation category48 Change the east to 2849 On Definition tab, change diffuser to grill50 Change the name of D-Box under grill to G-Box51 Open property page for G-box and change B to 1 6 and C to 152 Select Neck under G18X12REC12X8 and open its property page53 Change width to 1 and depth to 8

  • 8/8/2019 01 Sm3d Hvac Labs

    34/51

    HVAC Labs

    LAB-10: Copying To Catalog

    1 Select Diffuser D24X24REC8 in WSE2 Select Edit, Copy to Catalog3 Under type, select more and then select HVAC, HV Misc folder4 Type D24X24REC8 for name and hit Enter key5 System prompts for placement point, Select Bottom SW corner as placement

    point

    Note: A center point will be most logical point for placement. Since, we are going

    to use Grid plane for placement the corner point will be used.

    6 Ok to keep SP-Devices as the parent system7 Select Finish8 Copy D24X24RND8 to catalog using same steps and using D24X24RND8 for

    name.

    9 Copy G18X12REC12X8 to catalog also.

  • 8/8/2019 01 Sm3d Hvac Labs

    35/51

  • 8/8/2019 01 Sm3d Hvac Labs

    36/51

    HVAC Labs

    LAB-11: Branches with Offset

    1 Reposition target at the transition as shown

    2 Select Insert surface mount component command3 Key in -5 for North and select the duct straight feature shown in above picture4 Expand Surface, SMRectangularBranch and select SMRectabularBranch1

  • 8/8/2019 01 Sm3d Hvac Labs

    37/51

    HVAC Labs

    5 Click in the view to place the Branch 5 from Transition piece6 While Branch is selected, open its properties page from Ribbon Bar7 From Placement tab, make following changes to place the branch on West side

    8 Finish to place the Branch9 Change the locate filter to part and select the branch and open its property page10 Change the width and depth to 1

  • 8/8/2019 01 Sm3d Hvac Labs

    38/51

    HVAC Labs

    11 Route a duct from new branch 20 west12 Place other 2 Brach components as shown and route Ducts

  • 8/8/2019 01 Sm3d Hvac Labs

    39/51

    HVAC Labs

    LAB-12: Placing Diffusers

    1 Hide elevation plane at 02 Show Grid plane at 15 (if hidden)3 Select Edit, Place from Catalog4 Select D24X24REC85 Keep the same Parent system and OK6 Place the Diffuser at the grid intersection shown (You do not need to place the

    diffusers at the exact same intersection as shown. Approximate location will work)

  • 8/8/2019 01 Sm3d Hvac Labs

    40/51

    HVAC Labs

    7 Place D24X24RND8 diffusers at the shown locations

  • 8/8/2019 01 Sm3d Hvac Labs

    41/51

    HVAC Labs

    LAB-13: Diffuser Hook Up

    1 Connect All Select D24X24REC8 diffusers to closest ducts using Spec-1 as shown inthe picture.

    Note: Do not connect D24X24RND8 at this time

  • 8/8/2019 01 Sm3d Hvac Labs

    42/51

    HVAC Labs

    2 Reposition Target to the center of Neck of diffuser D24X24RND8 shown as 1 inabove picture

    3 Select Insert Surface Mount component command4 Select the duct shown in picture

    5

    Select SMRoundBranch1 from catalog

    6 Key in 0 for North and click in the view7 Open property page for branch and locate the Branch on the same side as Diffuser

    and change the offset to 3

    8 Finish to place the branch9 Change the locate filter to duct parts and select the branch component placed in

    above steps

    10

    Change the width to 8

    11 Connect the diffuser to the branch component using Spec-0

  • 8/8/2019 01 Sm3d Hvac Labs

    43/51

    HVAC Labs

    12 Connect all D24X24RND8 diffusers to ducts using SMRoundBranch1 componentwith 3 offset and Spec-0

  • 8/8/2019 01 Sm3d Hvac Labs

    44/51

    HVAC Labs

    LAB-14: Placing Dampers/Access Doors

    1 Select insert In-line component command2 Select the duct as shown

    3 From Catalog expand Fire Dampers and select, FD24X244 Locate and place the damper as shown5 Place other inline and Surface mount components as shown.

  • 8/8/2019 01 Sm3d Hvac Labs

    45/51

    HVAC Labs

  • 8/8/2019 01 Sm3d Hvac Labs

    46/51

    HVAC Labs

    LAB-15: Placing Spli ts

    1 Reposition target to the EF of Branch duct as shown

    2

    Select insert split command

    3 Select the duct shown in the above picture4 Select Rect_FlatFlange under type5 Key in -7 for east and place the flanges 7 feet apart as shown

    Note: If flange is placed where a branch is connected, relocate the branch

  • 8/8/2019 01 Sm3d Hvac Labs

    47/51

    HVAC Labs

    6 Placed weld on the 1X1 ducts as shown

  • 8/8/2019 01 Sm3d Hvac Labs

    48/51

    HVAC Labs

    LAB-16: Placing Insulation

    1 Turn Insulation aspect on from Format, View2 Change locate filter to Duct Runs3 Select the Duct Run branching from TEE as shown in the picture4 Open Properties page and change Insulation material to FBG and thickness to 45 Create a Surface style rule to show insulation as Translucent Orange

  • 8/8/2019 01 Sm3d Hvac Labs

    49/51

    HVAC Labs

    LAB-17: Return System (Optional)

    1 Connect to Return Connection on the East side of AHU2 Place a Rectangular to Round transition with 2 dia3 Rout to 20 6 elevation using 90 degree bend as shown

    4 Place Grills G18X12REC12X8 at shown location5 Route ducts as shown for return system and connect the grills6 Use Round, 8 duct to connect grills to main ducts as shown

  • 8/8/2019 01 Sm3d Hvac Labs

    50/51

    HVAC Labs

    Return System is shown in Darker Color

  • 8/8/2019 01 Sm3d Hvac Labs

    51/51

    HVAC Labs