    CIENA CONFIDENTIAL AND PROPRIETARY

    ONLINE M ETRO MULTISERVICE DENSE W AVE DIVISION MULTIPLEXING

    (DWDM) T RANSPORT P LATFORM

    Release 6.1

    INSTALLATION , TURN -UP , AND TEST M ANUAL

    CIENA Part Number: 009-2003-294November 3, 2003

    Revision A - Change 1

  • 7/29/2019 009-2003-294 Install Test and Turn Up.pdf

    2/300

    CIENA CONFIDENTIAL AND PROPRIETARY

    LEGAL NOTICES

    THIS DOCUMENT CONTAINS CONFIDENTIAL AND TRADE SECRET INFORMATION OF CIENA

    CORPORATION AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE ORDISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE, OR SELL ANYTHING THAT IT MAY DESCRIBE.REPRODUCTION, DISCLOSURE, OR USE IN WHOLE OR IN PART WITHOUT THE SPECIFIC WRITTEN

    AUTHORIZATION OF CIENA CORPORATION IS STRICTLY FORBIDDEN.

    EVERY EFFORT HAS BEEN MADE TO ENSURE THAT THE INFORMATION IN THIS DOCUMENT IS COMPLETE AND ACCURATE AT THE TIME OF PRINTING; HOWEVER, THE INFORMATION CONTAINED IN THISDOCUMENT IS SUBJECT TO CHANGE.

    Copyright 2003 CIENA Corporation

    Unpublished All Rights Reserved

    The material contained in this document is also protected by copyright laws of the United States of America and other countries. It may not be reproduced or distributed in any form by any means, altered in any fashion, or stored in a database or retrieval system, without express written permission of the CIENA Corporation.

    Required Customer InformationSecurity

    CIENA cannot be responsible for unauthorized use of equipment and will not make allowance or credit for unauthorized use or access.

    Contacting CIENA

    For additional office locations and phone numbers, please visit the CIENA web site at: www.ciena.com.

    Corporate Headquarters 410-694-5700 www.ciena.com

    Customer Technical Support/Warranty

    In North America 1-800-CIENA24 (243-6224) E-mail: [email protected]

    In Europe +44 (0)208 7506428 E-mail: [email protected]

    In Asia +81 3 3248 4680 E-mail: [email protected]

    Sales and General Information 410-694-5700 E-mail: [email protected]

    In North America 410-694-5700 E-mail: [email protected]

    In Europe +44-207-012-5500 (UK) E-mail: [email protected]

    In Asia +81-3-3248-4680 (Japan) E-mail: [email protected]

    In Latin America 561-620-1925 E-mail: [email protected]

    Training and Documentation

    Training 877-CIENA-TD (243-6283)or 410-694-8120

    E-mail: [email protected]

    Documentation877-CIENA-TD (243-6283)

    or 410-694-8125E-mail: [email protected]

  • 7/29/2019 009-2003-294 Install Test and Turn Up.pdf

    3/300

    Installation, Turn-up, and Test ManualSeptember 30, 2003 - Revision A009-2003-294 i

    CIENA CONFIDENTIAL AND PROPRIETARY

    ONLINE Metro Platform

    PREFACE

    DISCLAIMER

    Portions of this document are intended solely as an outline of methodologies to be followed during the

    installation, turn-up, and test of the ONLINE Metro Multiservice Dense Wave Division Multiplexing(DWDM) Transport Platform. It is not intended as a step-by-step guide or a complete set of all proceduresnecessary and sufficient to complete installation, turn-up and testing of the ONLINE Metro Platform.

    While every effort has been made to ensure that this document is complete and accurate at the time of printing, theinformation that it contains is subject to change. CIENA is not responsible for any additions to or alterations of theoriginal document. Networks vary widely in their configurations, topologies, and traffic conditions. This document isintended as a general guide only. It has not been tested for all possible applications, and it may not be complete or accurate for some situations.

    Procedures and information contained in this document for which this disclaimer applies are preceded bythe Disclaimer Banner, shown below.

    R E F E R T O D I S C L A I M E R I N P R E F A C E !

    Users of this document are urged to heed warnings interspersed throughout the document, such as trafficdisruption warnings.

    COMPLIANCE INFORMATION

    Food and Drug Administration (FDA) Laser Safety Warning

    This product contains a laser diode. CIENA Corporation strongly recommends that users, maintenance, andservice personnel comply with the following standards and regulations in the design, modification,operation, maintenance, an service of lasers and fiber-optic devices:

    It is further recommended that the owner of this equipment determine and ensure conformance with anyspecific and applicable local regulations.

    Jurisdiction Type TitleFederal, US Regulation FDA 21 CFR 1040.10/.11Federal, US Guidelines OSHAInternational Standard ANSI Z136 seriesInternational Standard IEC-825 seriesInternational Standard EN-60825

    Warning:

    LASER RADIATION EXPOSURE

    Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiationexposure.

  • 7/29/2019 009-2003-294 Install Test and Turn Up.pdf

    4/300

    ONLINE Metro Platform

    Installation, Turn-up, and Test ManualSeptember 30, 2003 - Revision A

    ii 009-2003-294CIENA CONFIDENTIAL AND PROPRIETARY

    Class I Laser Product Notice

    The CIENA Corporation ONLINE Metro Platform product is a Class 1 Laser product as identified by USFDA/CDRH 21CFR1040.10/.11; Class 1 Laser product as defined by IEC825/EN-60825; and OFCS SG1as defined by ANSI Z136.1/.2/

    Part 15 of the Federal Communications Commission (FCC): InterferenceEvery effort has been made to ensure that this equipment is designed to comply with the limits for a Class

    A digital device, as described in the FCC Rules. Equipment limitations are designed to provide reasonableprotection against harmful interference when the equipment is operated in a commercial environment. Thisequipment, if not installed and used properly, and in accordance with guidelines established by CIENACorporation may cause interference with other communications equipment. Operations of this equipment ina residential environment may cause interference and is the responsibility of the user to correct theinterference at his own expense.

    Environmental Impact Statement

    CIENA equipment contains no hazardous materials as defined by the United States Environmental

    Protection Agency (USEPA). CIENA recommends that all failed product be returned to CIENA for failureanalysis and proper disposal.

    Toxic Emissions

    CIENA equipment releases no toxic emissions.

    Telcordia Document Standards

    The format and structure of this document is derived from the Telcordia Generic Requirements for Supplier-Provided Documentation, GR-454-CORE.

    TRADEMARK ACKNOWLEDGEMENTS

    u CIENA is a registered trademark of CIENA Corporation.u ONLINE Metro Multiservice Dense Wave Division Multiplexing (DWDM) Transport Platform

    is a trademark of CIENA Corporation.

    u Windows 95/98/2000 and Windows NT are registered trademarks of the MicrosoftCorporation.

    u Microsoft is either a registered trademark or trademark of Microsoft Corporation in the UnitedStates and/or other countries.

    u UNIX is a registered trademark licensed exclusively through X/Open Company, Ltd.

    u Pentium is a registered trademark of Intel Corporation.

    u Sun, Sun Microsystems, JAVA, Java Secure Socket Extension, and JAVAX are trademarks or registered trademarks of Sun Microsystems, Inc. in the U.S. or other countries. This productincludes code licensed from RSA Data Security.

  • 7/29/2019 009-2003-294 Install Test and Turn Up.pdf

    5/300

    Installation, Turn-up, and Test ManualSeptember 30, 2003 - Revision A009-2003-294 iii

    CIENA CONFIDENTIAL AND PROPRIETARY

    ONLINE Metro Platform

    RELEASE NOTES AND DOCUMENT UPDATES

    The hard copy and Compact Disc Read Only Memory (CD-ROM) versions of this document are revised onlyat major releases and, therefore, may not always contain the latest product information. As needed,Software Release Documents (SRDs), Hardware Release Documents (HRDs), Application Notes, FieldService Bulletins (FSBs), and/or Document Maintenance Bulletins (DMBs) will be provided between major releases to describe any new information or document changes.

    The latest online version of this document and all release notes can be accessed via the CIENA web site athttp://www.ciena.com .

    PRINTING HISTORY

    The following information lists the printing history of this document.

    RELATED DOCUMENTATION

    All CIENA documentation is available in both hard copy and on CD-ROM. The following list provides a brief description of the related documents. Additional supporting documentation is available through the CIENAweb site at http://www.ciena.com .

    u ONLINE Metro Multiservice Dense Wave Division Multiplexing (DWDM) Transport PlatformSystem Description Manual

    u ONLINE Metro Multiservice Dense Wave Division Multiplexing (DWDM) Transport Platform Alarm and Trouble Clearing Manual

    u ONLINE Metro Multiservice Dense Wave Division Multiplexing (DWDM) Transport PlatformONLINE Metro Node Installer User Manual

    u ONLINE Metro Multiservice Dense Wave Division Multiplexing (DWDM) Transport PlatformCLI Reference Manual

    u ONLINE Metro Multiservice Dense Wave Division Multiplexing (DWDM) Transport PlatformCLI User Manual

    u ONLINE Metro Multiservice Dense Wave Division Multiplexing (DWDM) Transport PlatformSNMP Reference Manual

    u ONLINE Metro Multiservice Dense Wave Division Multiplexing (DWDM) Transport PlatformMaintenance and Upgrade Manual

    u ONLINE Metro Multiservice Dense Wave Division Multiplexing (DWDM) Transport PlatformSoftware Release Documents (SRDs)

    u ONLINE Metro Multiservice Dense Wave Division Multiplexing (DWDM) Transport PlatformTL1 Administration and Reference Manual

    u ONLINE Metro Multiservice Dense Wave Division Multiplexing (DWDM) Transport PlatformEngineering and Planning Manual

    u ONLINE Metro Multiservice Dense Wave Division Multiplexing (DWDM) Transport PlatformCraft Interface Terminal (CIT) User Manual

    Issue/Revision Release Date Content Description

    009-2002-620, Revision A January 2003 First printing009-2003-077, Revision A April 2003 Second Printing

    009-2003-294, Revision A September 2003 Third Printing

    http://www.ciena.com/http://www.ciena.com/http://www.ciena.com/http://www.ciena.com/
  • 7/29/2019 009-2003-294 Install Test and Turn Up.pdf

    6/300

    ONLINE Metro Platform

    Installation, Turn-up, and Test ManualSeptember 30, 2003 - Revision A

    iv 009-2003-294CIENA CONFIDENTIAL AND PROPRIETARY

    u LightWorks ON-Center Management Suite Metro Transport Manager CORBA GatewayReference Manual

    u LightWorks ON-Center Management Suite Metro Transport Manager Netcool GatewayReference Manual

    u

    LightWorks ON-Center

    Management Suite Metro Transport Manager (MTM) Software Administration Manual

    u LightWorks ON-Center Management Suite Metro Transport Manager (MTM) Software User Manual

    u LightWorks ON-Center Management Suite Metro Transport Manager TL1 Concentrator Gateway Manual

    u LightWorks ON-Designer ONLINE Metro Designer User Manual

    Related SRDs are available from the CIENA Training and Documentation web site.

    DOCUMENT ORDERING INFORMATION

    To order additional documentation, the user may contact the local sales representative or CIENA throughthe contact numbers and/or e-mail addresses listed on the back of the cover.

    DOCUMENT COMMENTS

    CIENA appreciates all comments that will help us improve our documentation quality. The user can submitcomments through our web site ( http://www.ciena.com ) or with the Documentation Improvement Requestform included with this document.

    ADDITIONAL PRODUCT INFORMATION

    Additional product information can be obtained by contacting the local sales representative or CIENAthrough the contact numbers and/or e-mail addresses listed on the back of the cover.

  • 7/29/2019 009-2003-294 Install Test and Turn Up.pdf

    7/300

    ONLINE Metro Platform TABLE OF CONTENTSTOC

    Installation, Turn-up, and Test ManualSeptember 30, 2003 - Revision A009-2003-294 v

    CIENA CONFIDENTIAL AND PROPRIETARY

    TABLE OF CONTENTS

    PREFACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i

    LIST OF FIGURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii

    LIST OF TABLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xix

    CHAPTER 1 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1

    Required Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1

    Prerequisites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1

    How to Use This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2

    Before Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2

    Site Survey Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2

    General Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3

    Voltage Precaution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3

    General Static Electricity Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3

    General Laser Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4

    General Optical Fiber Handling Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5

    General Fiber Break and Damaged Fiber Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5

    General Circuit Pack Handling Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5

    General Circuit Pack Storage Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6

    Warnings and Cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6

    Environmental Impact Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6Test Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7

    CHAPTER 2 SITE PREPARATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1

    About the ONLINE Metro Platform system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-1

    Power and Grounding Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1

    Rack Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1

    Unpacking and Verifying System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1

    CHAPTER 3 SHELF AND TRAY INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1

    Shelf Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1

    Shelf Compatibilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3

    Shelf Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3

    Shelf Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3

  • 7/29/2019 009-2003-294 Install Test and Turn Up.pdf

    8/300

    TABLE OF CONTENTS ONLINE Metro PlatformTOC

    Installation, Turn-up, and Test ManualSeptember 30, 2003 - Revision A

    vi 009-2003-294CIENA CONFIDENTIAL AND PROPRIETARY

    Shelf Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4

    Connecting the System Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4

    Installing Fuse or Circuit Breaker Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4

    Backplane Verification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4

    Installing a Shelf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5

    Telect Tray Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7

    Dispersion Compensation Module Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7

    Verifying Ground, Supply Voltage, and Polarity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-10

    Overview of Power Sources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12

    Connecting Power Input Cables to -48 VDC Power Source . . . . . . . . . . . . . . . . . . . . . . . . 3-12

    Connecting Power Input Cables to the 19V and 23V Shelves . . . . . . . . . . . . . . . . . . . . . . 3-13

    Shelf Cooling Equipment Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13Installing Assemblies in the Blower-Air Plenums (19V or 23V) . . . . . . . . . . . . . . . . . . . . . . 3-13

    Installing Cooling Fan Trays (19V or 23V) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-14

    Air Inlet Filter (19V or 23V) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-15

    Verifying Fan Tray Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-16

    CHAPTER 4 INSTALLING CIRCUIT PACKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-1

    Shelf Backplane Connectors and CP Positions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1

    Circuit Pack Slot Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-2

    Inserting Circuit Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2

    Circuit Pack Latching Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4

    Main Shelf Circuit Pack Latching Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5

    Additional Expansion Shelves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-9

    CHAPTER 5 CABLE AND FIBER MANAGEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1

    Connecting Fibers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1

    Guidelines for Handling and Working with Fibers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1

    Use of PADs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-2

    Dual MU Bulkhead Connector Convention . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-2

    Managing Fibers and Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2

    Fiber Management Trays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3

    Connecting Circuit Pack Fibers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4

  • 7/29/2019 009-2003-294 Install Test and Turn Up.pdf

    9/300

    ONLINE Metro Platform TABLE OF CONTENTSTOC

    Installation, Turn-up, and Test ManualSeptember 30, 2003 - Revision A009-2003-294 vii

    CIENA CONFIDENTIAL AND PROPRIETARY

    CHAPTER 6 PROVISIONING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1

    Task Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-1

    Verify Site Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1

    Verify ONLINE Metro CIT Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2

    Initializing the NE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4

    Initializing the NE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4

    Provisioning Circuit Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-15

    Provisioning Circuit Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-15

    Provisioning Line Circuit Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-15

    Adding a Line Card to the Main Shelf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-16

    Provisioning AMP Circuit Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-17

    Provisioning BWDM Circuit Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-18Provisioning CWDM Circuit Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-20

    Provisioning WCI Circuit Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-22

    Configuring OC-48 STMX and STEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-24

    Provision Gigabit-Rate Data Mux (GRDM and GRDMII) CPs . . . . . . . . . . . . . . . . . . . . . . . 6-28

    Assign Line-side OC-48 Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-28

    Adding a WCI Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-28

    Add GRDM and GRDMII CPs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-30

    Creating GRDMII ONWAVE Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-35

    Overhead Provisioning on GRDMII . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-40

    Configuring DCC On GRDMII . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-41

    Configuring PPP On GRDMII . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-42

    Set Fault Propagation Mode On GRDM And GRDMII . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-43

    Provisioning a WCI10G-LAN Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-44

    Provisioning Splitter Circuit Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-45

    Provisioning PMM Circuit Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-45

    Provisioning SYNC Circuit Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-46

    Provisioning an ONWAVE Node With SMX-10G CP . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-47Configure ADM/SMX ONWAVE Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-52

    Provisioning ESCON and ESCONII Mux (EMX12) CPs . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-57

    Adding a WCI Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-57

    Adding An ESCON And ESCONII MUX Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-60

    Creating ESCONII ONWAVE Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-62

  • 7/29/2019 009-2003-294 Install Test and Turn Up.pdf

    10/300

    TABLE OF CONTENTS ONLINE Metro PlatformTOC

    September 30, 2003Novembe r 3, 2003 - Revision A - Change 1

    viii 009-2003-294CIENA CONFIDENTIAL AND PROPRIETARY

    Set Overhead Provisioning On ESCONII . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-66

    Configuring DCC On ESCONII . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-68

    Configuring PPP on ESCONII . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-69

    Provisioning Channel Pass-Through . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-69

    Provisioning Band Pass-Through . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-70

    Provisioning Dispersion Compensation Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-71

    Configuring Span Attributes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-72a

    To Modify Span Loss for a Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-72a

    Circuit Provisioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-73

    Creating 3rd party DWDM circuits with CWMD-U Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-77

    Creating 3rd party DWDM circuits with CWMD-UE Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-80

    Set Optical Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-83 Add External Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-84

    Provisioning 3rd Party DWDM Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-85

    Displaying 3rd Party DWDM Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-87

    Displaying 3rd Party DWDM Circuit Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-88

    Modifying 3rd Party DWDM Circuits and External Interfaces . . . . . . . . . . . . . . . . . . . . . . . 6-89

    Provisioning Stand Alone DWDM Nodes (Virtual Nodes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-91

    Supported Stand-alone DWDM CPs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-91

    Supported Stand-alone DWDM Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-92

    Provisioning a Stand-alone DWDM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-93

    Modifying a VNE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-97

    Provision a Band Pass-through . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-98

    Provision a Channel Pass-through . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-99

    CHAPTER 7 VERIFICATION PROCEDURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1

    Confirming CPs are Provisioned . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1Reading CP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1Complete List of CP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3

    ABWDM And ABWDM-U LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-3

    10 GbE LAN LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4

    ADM CP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-4

    ADMII CP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-5

    Power ACO Card Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-5

    Alarm LED Card LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-5

    BWDM & BWDM-U LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-6

  • 7/29/2019 009-2003-294 Install Test and Turn Up.pdf

    11/300

    ONLINE Metro Platform TABLE OF CONTENTSTOC

    Installation, Turn-up, and Test ManualSeptember 30, 2003 - Revision A009-2003-294 ix

    CIENA CONFIDENTIAL AND PROPRIETARY

    COM CP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-6

    CWDM LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-7

    EMX12 LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-7

    GRDM LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-8

    Line CP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-8

    OLM CP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-9

    OSCH CP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-10

    OSM CP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-10

    PEM LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-11

    PMM CP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-11

    Post-Amp CP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-12

    Power Entry Card LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-12Power LED Card LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-12

    Pre-Amp CP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-13

    PSM CP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-13

    RSM CP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-14

    SMX-04 10G CP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-14

    STEM CP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-15

    STMX CP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-15

    VGA CP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-16

    WCI CP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-17

    WPS CP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-17

    Initial Checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-18

    Optical Verification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-23

    For BLSR Subnetworks with WCA Circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-23

    For a UPSR, Pt-Pt, LADM, or BLSR with Only UCA Circuits . . . . . . . . . . . . . . . . . . . . . . . 7-24

    Important Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-28

    Labeling Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-30

    Customer Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-31Line Fibers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-31

    Tributary Fibers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-31

    Attenuator Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-32

    Band Pass-through . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-33

  • 7/29/2019 009-2003-294 Install Test and Turn Up.pdf

    12/300

    TABLE OF CONTENTS ONLINE Metro PlatformTOC

    Installation, Turn-up, and Test ManualSeptember 30, 2003 - Revision A

    x 009-2003-294CIENA CONFIDENTIAL AND PROPRIETARY

    Channel Pass-through . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-33

    All Other Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-33

    Thin Mux (STMX), Data Mux (GRDM), and ADM CP Provisioning and Testing . . . . . . . . . . . . 7-34

    STMX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-34

    GRDM/GRDMII . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-34

    ADM/ADMII . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-35

    APPENDIX A TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1

    Troubleshooting Span Loss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-1

    Troubleshooting CP Boot-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2

    If Problems Persist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2

    Troubleshooting CP Provisioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-3Troubleshooting Expansion Shelf Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-3

    Setting Shelf Number Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-4

    Troubleshooting Ethernet Connections Between Shelves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-6

    Troubleshooting Power Conversions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-8

    Troubleshooting Database Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-9

    For Networks Running 3.2.2 Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-9

    For Networks Running Software Loads 3.2.3 and Above . . . . . . . . . . . . . . . . . . . . . . . . . .A-10

    Troubleshooting Optical Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-10

    10 GbE LAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-10

    ADM CPs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-11

    ADM II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-12

    ESCON MUX (EX12) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-14

    GRDM CPs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-14

    GRDM II CPs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-15

    STMX CPs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-16

    WCI CPs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-16

    Intermediate-Reach Trib . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-182R ESCON/ETR WCI CP Optical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-19

    3R and 3R Enhanced WCI CP Optical Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-21

    2R 850-nm WCI CP Optical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-22

    2R 1310-nm WCI CP Optical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-23

    3R OC-192 CPs And MetroCor Fiber WCI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-24

  • 7/29/2019 009-2003-294 Install Test and Turn Up.pdf

    13/300

    ONLINE Metro Platform TABLE OF CONTENTSTOC

    Installation, Turn-up, and Test ManualSeptember 30, 2003 - Revision A009-2003-294 xi

    CIENA CONFIDENTIAL AND PROPRIETARY

    3R OC-192 WCI w/FEC CP Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-25

    Troubleshooting Cooling Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-25

    19V and 23V Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-25

    APPENDIX B SPAN LOSS QUICK REFERENCE GUIDE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-1

    Order Of Accuracy For Valid Span Loss Results: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-1

    Criteria for PIN Diode Saturation: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1

    Criteria for VOA Open Condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1

    Rule of Thumb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1

    Fiber Pair Balancing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-2

    APPENDIX C SHELF ACCESSORY INSTALLATION & SLOT ASSIGNMENTS . . . . . . . . . . . . .C-1

    Installing Power Entry Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-1

    Installing Alarm I/O Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-2

    Install an Alarm I/O Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-2

    Installing Power/Alarm Cut-off LED Card in Main Shelf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-3

    Install the Power/alarm Cutoff LED Card in the Main Shelf . . . . . . . . . . . . . . . . . . . . . . . . . C-3

    Installing Alarm LED Card in Main Shelf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-4

    Install the Alarm LED Card in the Main Shelf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-4

    Installing Power LED Card in Expansion Shelf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-4Install the Power LED Card in the Expansion Shelf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-4

    Shelf Slot Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-5

    Slot Assignments of Two Sonet/SDH Multiplexer (SMX) CPs Operating As Pairs . . . . . . .C-5

    Slot Assignments of Two WCI CPs Operating As a UPSR Pair . . . . . . . . . . . . . . . . . . . . . C-6

    O-BLSR, O-UPSR, And Linear ADM Slot Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . .C-7

    APPENDIX D CONNECTOR PINOUTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-1

    Front Panel Connectors and Electrical Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-1

    Alarm I/O Card Connector Pins (23-inch Shelf) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-1

    CO Alarm Interface 25-Pin Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-2

    User Alarm Interface 62-Pin Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-3

  • 7/29/2019 009-2003-294 Install Test and Turn Up.pdf

    14/300

    TABLE OF CONTENTS ONLINE Metro PlatformTOC

    Installation, Turn-up, and Test ManualSeptember 30, 2003 - Revision A

    xii 009-2003-294CIENA CONFIDENTIAL AND PROPRIETARY

    Alarm I/O Card Connector Pins (23V and 19V Shelves) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-6

    CO Alarm I/O Card 26-Pin Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-6

    User Alarm I/O Card 40-Pin Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-7

    APPENDIX E FIBER AND BULKHEAD CLEANING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-1

    Maintaining Fibers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E-1

    Guidelines for Handling and Working with Fibers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-1

    Cleaning Fiber Ends and Bulkhead Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E-1

    APPENDIX F DATASHEETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .F-1

    Field Verification Results Reference Guide v4.2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F-1

    (1) Network Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F-1

    (2) Node Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F-2

    INDEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I-1

  • 7/29/2019 009-2003-294 Install Test and Turn Up.pdf

    15/300

    ONLINE Metro Platform LIST OF FIGURESLOF

    FIGURE # FIGURE NAME PAGE #

    Installation, Turn-up, and Test ManualSeptember 30, 2003 - Revision A009-2003-294 xiii

    CIENA CONFIDENTIAL AND PROPRIETARY

    LIST OF FIGURES

    Figure 3-1. Backplane Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5

    Figure 3-2. Mounting An ONLINE Metro Platform Shelf . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6

    Figure 3-3. Shelf Ground Strap Installation (19V or 23V) . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7Figure 3-4. Three 19V or 23V Shelves and One DCM-A . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8

    Figure 3-5. Three 19V or 23V Shelves and Two DCM-As . . . . . . . . . . . . . . . . . . . . . . . . . 3-9

    Figure 3-6. Checking the Shelf Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11

    Figure 3-7. Power Entry Card Connector (19V or 23V) . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13

    Figure 3-8. Fan Tray Cover Removal (19V or 23V) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-14

    Figure 3-9. Fan Tray Insertion (19Vor 23V) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-14

    Figure 3-10. Blower Connector and Backplane Plug Alignment (19V or 23V) . . . . . . . . . . . 3-15

    Figure 3-11. Air Inlet Filter Installation (19V and 23V) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-15

    Figure 4-1. Removing a CP from Its Antistatic Container . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3

    Figure 4-2. Inserting a CP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4

    Figure 4-3. Latching a CP in the Shelf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5

    Figure 5-1. PAD Installed On SC Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2

    Figure 5-2. Correct Fiber Routing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3

    Figure 5-3. Patch Fiber Management Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4

    Figure 5-4. Storage Fiber Management Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4

    Figure 6-1. CLI Login . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2

    Figure 6-2. CLI Show Version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3Figure 6-3. ONLINE Metro CIT Login . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4

    Figure 6-4. NE Setup Wizard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-5

    Figure 6-5. NE Setup Wizard 2nd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-5

    Figure 6-6. NE Setup Wizard 3rd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6

    Figure 6-7. NE Setup Wizard 4th . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7

    Figure 6-8. Choose Date/Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-8

    Figure 6-9. NE Setup Wizard NTP Client . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-9

    Figure 6-10. NE Setup Wizard Change Password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-10

    Figure 6-11. NE Setup Wizard Select Topology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-10

    Figure 6-12. NE Setup Wizard Optical Circuit Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-11

    Figure 6-13. NE Setup Wizard Set Amp Configuration and VOA Mode . . . . . . . . . . . . . . . . 6-11

    Figure 6-14. NE Setup Wizard O-BLSR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-12

  • 7/29/2019 009-2003-294 Install Test and Turn Up.pdf

    16/300

    LIST OF FIGURES ONLINE Metro PlatformLOF

    FIGURE # FIGURE NAME PAGE #

    Installation, Turn-up, and Test ManualSeptember 30, 2003 - Revision A

    xiv 009-2003-294CIENA CONFIDENTIAL AND PROPRIETARY

    Figure 6-15. NE Setup Wizard Fiber Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-13

    Figure 6-16. NE Setup Wizard Node ID Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-14

    Figure 6-17. NE Setup Wizard Success Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-14Figure 6-18. Add Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-15

    Figure 6-19. Add Line Card Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-16

    Figure 6-20. Setting Span Attributes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-17

    Figure 6-21. Add Amplification Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-18

    Figure 6-22. Add BWDM Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-19

    Figure 6-23. Add CWDM Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-20

    Figure 6-24. Set VOA Attenuation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-21

    Figure 6-25. Add WCI Card Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-22

    Figure 6-26. WCI Types in the ADD WCI Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-23

    Figure 6-27. Add WCI Card Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-24

    Figure 6-28. Add STMX Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-25

    Figure 6-29. Add STEM Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-27

    Figure 6-30. ADD WCI Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-29

    Figure 6-31. WCI Types in the ADD WCI Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-30

    Figure 6-32. Provision GRDM Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-31

    Figure 6-33. Modify Line Trail Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-32

    Figure 6-34. Connect Line Port Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-32Figure 6-35. Modify Line Trail Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-33

    Figure 6-36. GRDM AND GRDMII Facilities in ONLINE Metro CIT Tree . . . . . . . . . . . . . . . 6-34

    Figure 6-37. Provision ONWAVE Node Configuration Window . . . . . . . . . . . . . . . . . . . . . . 6-35

    Figure 6-38. Configure ONWAVE Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-36

    Figure 6-39. Add GRDM Card Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-36

    Figure 6-40. Configure ONWAVE Node Configuration Window With Single GRDMII. . . . . . 6-37

    Figure 6-41. Connect Line Port Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-37

    Figure 6-42. Configure ONWAVE Node Configuration Window With Connection . . . . . . . . 6-38

    Figure 6-43. Configure ONWAVE Node GRDMII Pair Configuration Window . . . . . . . . . . . 6-39

    Figure 6-44. Overhead Provisioning Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-40

    Figure 6-45. Configure DCC Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-41

    Figure 6-46. Configure PPP Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-42

  • 7/29/2019 009-2003-294 Install Test and Turn Up.pdf

    17/300

    ONLINE Metro Platform LIST OF FIGURESLOF

    FIGURE # FIGURE NAME PAGE #

    Installation, Turn-up, and Test ManualSeptember 30, 2003 - Revision A009-2003-294 xv

    CIENA CONFIDENTIAL AND PROPRIETARY

    Figure 6-47. Modify GRDM Fault Propagation Mode Dialog Box . . . . . . . . . . . . . . . . . . . . . 6-43

    Figure 6-48. Add WCI Card Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-44

    Figure 6-49. Add Splitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-45Figure 6-50. Add PMM Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-46

    Figure 6-51. Add SYNC Card Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-47

    Figure 6-52. Provision ONWAVE Node Configuration Window . . . . . . . . . . . . . . . . . . . . . . 6-48

    Figure 6-53. Configure ONWAVE Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-49

    Figure 6-54. Add ADM/SMX Card Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . . 6-49

    Figure 6-55. Configure ONWAVE Node Configuration Window With Single SMX-10G. . . . 6-50

    Figure 6-56. Connect Line Port Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-50

    Figure 6-57. Configure ONWAVE Node Configuration Window With Connection . . . . . . . . 6-51

    Figure 6-58. Provision ONWAVE Node Configuration Window . . . . . . . . . . . . . . . . . . . . . . 6-52

    Figure 6-59. Configure ONWAVE Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-53

    Figure 6-60. Add ADM/SMX Card Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . . 6-54

    Figure 6-61. Configure ONWAVE Node Configuration Window With Single ADM. . . . . . . . 6-54

    Figure 6-62. Connect Line Port Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-55

    Figure 6-63. Configure ONWAVE Node Configuration Window With Connection . . . . . . . . 6-55

    Figure 6-64. Configure ONWAVE Node Configuration Window (Paired ADM Cards) . . . . . 6-56

    Figure 6-65. Configure ONWAVE Node Configuration Window . . . . . . . . . . . . . . . . . . . . . . 6-56

    Figure 6-66. Add WCI Card Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-57Figure 6-67. Modify Line Trail Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-58

    Figure 6-68. Connect Line Port Configuration window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-59

    Figure 6-69. Modify Line Trail Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-59

    Figure 6-70. Add ESCON MUX Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-60

    Figure 6-71. EXM-12 Ports In Tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-61

    Figure 6-72. Provision ONWAVE Node Configuration Window . . . . . . . . . . . . . . . . . . . . . . 6-62

    Figure 6-73. Configure ONWAVE node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-62

    Figure 6-74. Add ESCONII Card Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-63

    Figure 6-75. Configure ONWAVE Node Configuration Window with Single ESCONII. . . . . 6-64

    Figure 6-76. Connect Line Port Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-64

    Figure 6-77. Configure ONWAVE Node Configuration Window With Connection . . . . . . . . 6-65

    Figure 6-78. Configure ONWAVE Node ESCONII Pair Configuration Window . . . . . . . . . . 6-66

  • 7/29/2019 009-2003-294 Install Test and Turn Up.pdf

    18/300

    LIST OF FIGURES ONLINE Metro PlatformLOF

    FIGURE # FIGURE NAME PAGE #

    Installation, Turn-Up and Test ManualNovembe r 3, 2003 - Revision A - Change 1

    xvi 009-2003-294CIENA CONFIDENTIAL AND PROPRIETARY

    Figure 6-79. Overhead Provisioning Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-67

    Figure 6-80. Configure DCC Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-68

    Figure 6-81. Configure PPP Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-69Figure 6-82. Add Channel Pass Through . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-70

    Figure 6-83. Add Band Pass Through . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-70

    Figure 6-84. Add DCM Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-71

    Figure 6-85. DCM List Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-72

    Figure 6-85a Set Span Loss Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-72a

    Figure 6-86. ONLINE Metro CIT Main Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-73

    Figure 6-87. Circuits Directory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-74

    Figure 6-88. Provisioning Circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-74

    Figure 6-89. Circuit Attributes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-75

    Figure 6-90. Retrieving Circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-76

    Figure 6-91. Band-Only Circuit Using Channel 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-78

    Figure 6-92. Full Band 3rd Party . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-78

    Figure 6-93. Full Band 3rd Party Pass Thru (Ring-to-Ring) . . . . . . . . . . . . . . . . . . . . . . . . . 6-79

    Figure 6-94. Channelized 3rd Party DWDM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-79

    Figure 6-95. Channelized Third Party DWDM (Ring-to-Ring) . . . . . . . . . . . . . . . . . . . . . . . . 6-80

    Figure 6-96. Unprotected Channelized 3rd Party DWDM (CWDM-UE) . . . . . . . . . . . . . . . . 6-81

    Figure 6-97. O-UPSR Protected Channelized 3rd Party DWDM (CDWM-UE) . . . . . . . . . . . 6-81Figure 6-98. O-UPSR Protected Channel Pass Through 3rd Party DWDM (CDWM-UE) . . 6-82

    Figure 6-99. Channel Pass Through 3rd Party DWDM (CWDMU and CDWM-UE) . . . . . . . 6-82

    Figure 6-100. Set Optical Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-83

    Figure 6-101. Add External Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-84

    Figure 6-102. External Interface In ONLINE Metro CIT Tree . . . . . . . . . . . . . . . . . . . . . . . . . 6-85

    Figure 6-103. Provision Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-85

    Figure 6-104. Provision Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-86

    Figure 6-105. External Interface Circuit In ONLINE Metro CIT Tree . . . . . . . . . . . . . . . . . . . 6-86

    Figure 6-106. External Interface Circuit In Channel Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-87

    Figure 6-107. 3rd Party DWDM Circuit In Display Window . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-88

    Figure 6-108. 3rd Party DWDM Circuit Information Dialog Box . . . . . . . . . . . . . . . . . . . . . . . 6-89

    Figure 6-109. Modify Circuit Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-90

    Figure 6-110. Modify External Interface Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-90

  • 7/29/2019 009-2003-294 Install Test and Turn Up.pdf

    19/300

    ONLINE Metro Platform LIST OF FIGURESLOF

    FIGURE # FIGURE NAME PAGE #

    Installation, Turn-up, and Test ManualSeptember 30, 2003 - Revision A009-2003-294 xvii

    CIENA CONFIDENTIAL AND PROPRIETARY

    Figure 6-111. Stand-alone Node and DWDM in the Same Shelf . . . . . . . . . . . . . . . . . . . . . . 6-91

    Figure 6-112. Stand-alone with BWDM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-92

    Figure 6-113. Stand-alone DWDM (No BWDM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-93Figure 6-114. Provision VNE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-94

    Figure 6-115. Provision VNE Dialog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-94

    Figure 6-116. VNE Add BWDM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-95

    Figure 6-117. VNE Add CWDM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-96

    Figure 6-118. VNE Add WCI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-97

    Figure 6-119. Modify VNE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-98

    Figure 6-120. Add Band Pass Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-98

    Figure 6-121. Add Channel Pass Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-99

    Figure A-1. Set Shelf Number Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-4

    Figure A-2. Set Shelf Number (2nd) Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-5

    Figure A-3. Set Shelf Number Confirmation Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-5

    Figure A-4. Ethernet Cable Connections For One Expansion Shelf . . . . . . . . . . . . . . . . . . A-6

    Figure A-5. Ethernet Cable Connections For Two Expansion Shelves . . . . . . . . . . . . . . . . A-6

    Figure A-7. Ethernet Cable Connections For Four Expansion Shelves . . . . . . . . . . . . . . . A-7

    Figure A-6. Ethernet Cable Connections For Three Expansion Shelves . . . . . . . . . . . . . . A-7

    Figure C-1. Power Entry Card Installation (19V or 23V) . . . . . . . . . . . . . . . . . . . . . . . . . . . C-2

    Figure C-2. Alarm I/O Card Installation (19V or 23V) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-3Figure C-3. Alarm LED and Power/Alarm Cutoff LED Card Installation (19V or 23V) . . . . . C-4

    Figure C-4. Basic CP Configuration (23V Main Shelf) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-9

    Figure C-5. Basic BLSR Ring CP Configuration (23V Main Shelf) . . . . . . . . . . . . . . . . . . . C-10

    Figure C-6. Basic CP Configuration (23V Expansion Shelf) . . . . . . . . . . . . . . . . . . . . . . . . C-10

    Figure C-7. CP Configuration (19V Main Shelf) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-10

    Figure C-8. CP Configuration (19V Expansion Shelf) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-11

    Figure D-1. CO Alarm Interface 25-Pin Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-2

    Figure D-2. User Alarm 62-Pin Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-3

    Figure D-3. CO Alarm I/O Card 26-Pin Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-6

    Figure D-4. User Alarm I/O Card 40-pin Alarm Connector . . . . . . . . . . . . . . . . . . . . . . . . . D-7

    Figure E-1. Cleaning a Bulkhead Connector with Compressed Air . . . . . . . . . . . . . . . . . . . E-2

    Figure E-2. Folding Two Kimwipes to Form a 16-Ply Cleaning Pad . . . . . . . . . . . . . . . . . . E-3

  • 7/29/2019 009-2003-294 Install Test and Turn Up.pdf

    20/300

    LIST OF FIGURES ONLINE Metro PlatformLOF

    FIGURE # FIGURE NAME PAGE #

    Installation, Turn-up, and Test ManualSeptember 30, 2003 - Revision A

    xviii 009-2003-294CIENA CONFIDENTIAL AND PROPRIETARY

    Figure E-3. Cleaning a Fiber End Using a Folded Kimwipe Pad . . . . . . . . . . . . . . . . . . . . . E-4

    Figure E-4. Viewing a Fiber End with a Fiber Scope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-5

    Figure E-5. Examples of Fiber-End Views . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-5Figure E-6. Cleaning a Fiber End with a CLETOP Cleaning Device . . . . . . . . . . . . . . . . . . E-7

    Figure E-7. Removing a CLETOP Cleaning Stick from Its Wrapper . . . . . . . . . . . . . . . . . . E-9

    Figure E-8. Cleaning a Bulkhead Connector with a CLETOP Cleaning Stick . . . . . . . . . . . E-10

  • 7/29/2019 009-2003-294 Install Test and Turn Up.pdf

    21/300

    ONLINE Metro Platform LIST OF TABLESLOT

    TABLE # TABLE NAME PAGE #

    Installation, Turn-up, and Test ManualSeptember 30, 2003 - Revision A009-2003-294 xix

    CIENA CONFIDENTIAL AND PROPRIETARY

    LIST OF TABLES

    Table 3-1. Shelf Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3

    Table 3-2. Electrical Cables for Main Shelf (19V and 23V) . . . . . . . . . . . . . . . . . . . . . . . . 3-3

    Table 3-3. Electrical Cables for Each Expansion Shelf (23V and 19V) . . . . . . . . . . . . . . . 3-4Table 4-1. CP LED States After Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7

    Table 6-1. STMX and STEM CP Slot Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-26

    Table 6-2. STMX and STEM CP Slot Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-27

    Table 6-3. SMX-10G Cross connect Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-48

    Table 7-1. Correct Behavior Of LEDs After Booting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1

    Table 7-2. ABWDM LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3

    Table 7-3. 10GbE LAN WCI CP Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4

    Table 7-4. ADM LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4

    Table 7-5. ADMII LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-5

    Table 7-6. Power And ACO LED Card Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-5

    Table 7-7. Alarm LED Card LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-5

    Table 7-8. BWDM LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-6

    Table 7-9. COM CP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-6

    Table 7-10. CWDM LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-7

    Table 7-11. EMX12 LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-7

    Table 7-12. GRDM LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-8

    Table 7-13. Line CP LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-8Table 7-14. OLM CP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-9

    Table 7-15. OSCH CP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-10

    Table 7-16. OSM CP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-10

    Table 7-17. PEM LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-11

    Table 7-18. PMM CP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-11

    Table 7-19. Post-Amp CP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-12

    Table 7-20. Power Entry Card LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-12

    Table 7-21. Power LED Card LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-12

    Table 7-22. Pre-Amp CP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-13

    Table 7-23. PSM CP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-13

    Table 7-24. RSM CP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-14

    Table 7-25. SMX-04 10G CP LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-14

    Table 7-26. STEM CP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-15

  • 7/29/2019 009-2003-294 Install Test and Turn Up.pdf

    22/300

    LIST OF TABLES ONLINE Metro PlatformLOT

    TABLE # TABLE NAME PAGE #

    Installation, Turn-up, and Test ManualSeptember 30, 2003 - Revision A

    xx 009-2003-294CIENA CONFIDENTIAL AND PROPRIETARY

    Table 7-27. STMX CP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-15

    Table 7-28. VGA CP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-16

    Table 7-29. WCI CP Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-17

    Table 7-30. WPS CP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-17

    Table A-1. 3R 10GbE LAN -FEC WCI Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-10

    Table A-2. ADM Tributary Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-11

    Table A-3. ADM Line Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-11

    Table A-4. ADMII Tributary Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-12

    Table A-5. Transmit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-12

    Table A-6. Receive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-12

    Table A-7. Transmit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-13

    Table A-8. Receive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-13

    Table A-9. Transmit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-13

    Table A-10. Receive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-13

    Table A-11. EMX12 TX Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-14

    Table A-12. EMX12 RX Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-14

    Table A-13. GRDM CP Optical Tributary Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . A-14

    Table A-16. GRDM II CP Optical Line Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-15

    Table A-14. Additional Trib TX/ RX Optical Characteristics for 850 nm. . . . . . . . . . . . . . . . A-15

    Table A-15. GRDM CP Optical Line Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-15Table A-17. STMX CP Optical Tributary Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . A-16

    Table A-18. WCI SR Tributary-side Optical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . A-16

    Table A-19. Regional And Metro Rate-tunable IR Tributary-side Optical Specifications . . . A-18

    Table A-20. Regional Rate-Tunable And Metro Rate-tunable CP Line-side

    Optical Specifications A-18

    Table A-21. 2R ESCON/ETR WCI CP Tributary-side Optical Specifications . . . . . . . . . . . A-19

    Table A-22. 2R ESCON/ETR WCI CP Line-side Optical Specifications . . . . . . . . . . . . . . . A-20

    Table A-23. 3R and 3R Enhanced WCI CP Tributary-side Optical Specifications. . . . . . . . A-21

    Table A-24. 3R And 3R Enhanced WCI CP Line-side Optical Specifications . . . . . . . . . . . A-21

    Table A-25. 2R 850-nm WCI CP Tributary-side Optical Specifications . . . . . . . . . . . . . . . . A-22

    Table A-26. 2R 850-nm WCI CP Line-side Optical Specifications. . . . . . . . . . . . . . . . . . . . A-22

    Table A-27. 2R 1310-nm WCI CP Tributary-side Optical Specifications . . . . . . . . . . . . . . . A-23

    Table A-28. 2R 1310-nm WCI CP Line-side Optical Specifications. . . . . . . . . . . . . . . . . . . A-23

  • 7/29/2019 009-2003-294 Install Test and Turn Up.pdf

    23/300

    ONLINE Metro Platform LIST OF TABLESLOT

    TABLE # TABLE NAME PAGE #

    Installation, Turn-up, and Test ManualSeptember 30, 2003 - Revision A009-2003-294 xxi

    CIENA CONFIDENTIAL AND PROPRIETARY

    Table A-29. 3R OC-192 CPs and MetroCor Fiber WCI . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-24

    Table A-30. 3R OC-192-FEC WCI Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-25

    Table C-1. CP Slot Assignments (23V Main Shelf) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-9Table C-2. CP Slot Assignments (23V Expansion Shelf). . . . . . . . . . . . . . . . . . . . . . . . . . C-10

    Table C-3. CP Slot Assignments (19V Main Shelf) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-11

    Table C-4. CP Slot Assignments (19V Expansion Shelf). . . . . . . . . . . . . . . . . . . . . . . . . . C-11

    Table D-1. Panel Connectors For ONLINE Metro Platform . . . . . . . . . . . . . . . . . . . . . . . . D-1

    Table D-2. Alarm I/O Card Electrical Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-1

    Table D-3. CO Alarm Interface, DB25 Connector Pinout. . . . . . . . . . . . . . . . . . . . . . . . . . D-2

    Table D-4. User Alarm Interface, DB62 Connector Pinout. . . . . . . . . . . . . . . . . . . . . . . . . D-3

    Table D-5. CO Alarm I/O Card, HD26 Connector Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . D-6

    Table D-6. User Alarm I/O Card, HD40 Connector Pinout. . . . . . . . . . . . . . . . . . . . . . . . . D-7

  • 7/29/2019 009-2003-294 Install Test and Turn Up.pdf

    24/300

    THIS PAGE INTENTIONALLY LEFT BLANK

    LIST OF TABLES ONLINE Metro PlatformLOT

    Installation, Turn-up, and Test ManualSeptember 30, 2003 - Revision A

    xxii 009-2003-294CIENA CONFIDENTIAL AND PROPRIETARY

  • 7/29/2019 009-2003-294 Install Test and Turn Up.pdf

    25/300

    Installation, Turn-up, and Test ManualSeptember 30, 2003 - Revision A009-2003-294 1 - 1

    CIENA CONFIDENTIAL AND PROPRIETARY

    ONLINE Metro Platform INTRODUCTION1

    CHAPTER 1INTRODUCTION

    REQUIRED TOOLS

    u Windows 2000, or NT based Personal Computer (PC) equipped with a Compact Disc ReadOnly Memory (CD-ROM) drive

    u ONLINE Metro Multiservice Dense Wave Division Multiplexing (DWDM) Transport PlatformCraft Interface Terminal (CIT) software version matching the system software release

    u Straight-through CAT 5 cable with RJ-45 connectors

    u Standard CIENA installer tool kit including:u Torque wrench or torque driver with a 7/16-inch socket for torquing power input and return

    hardware to 65 inch-pounds (in-lb) (5 to 6 foot-pounds (ft-lb))u Digital Multimeter (DMM) with test leadsu Fiber Optic Cleaning Kit (Speer SFO 1400-NN-A, or equivalent)

    u Westover Scientific (Handheld) Inspection Scope (FBP-Series, or equivalent)

    u Video optical fiber scope (Micro Enterprises MODULE SCOPE ) with JVC Thin FilmTransistor (TFT) Liquid Crystal Diode (LCD) Video Monitor LT-V18 (if available) or an opticalfiber scope (Noyes OFS300, or equivalent) (with appropriate adapters)

    u Back Reflection Meter (EXFO BRT-320A, or equivalent)u Optical Power Meter (OPM) (Noyes OPM-4-4C, or equivalent)u Assorted Optical Attenuators, SC connector: 1dB through 28dB, inclusive (PADS)u Electrostatic Discharge (ESD) guard wrist strapu ESD guard heel groundersu APC/PC connector adapters

    u Kimberly-Clark Kimwipes EX-L Delicate Task Wipers (or equivalent)

    PREREQUISITES

    u The user must have a working knowledge of ONLINE Metro CIT software and connectivityu The user must have a knowledge of HyperTerminal and File Transfer Protocol (FTP) software

    setup and usage.u The user must have a knowledge of SONET test set operation.u The user must have a knowledge of OPM operation.u The user must have a knowledge of OSA operation.

    u The user must have a knowledge of CDTS operation.u The user must have a knowledge of Craft Interface usage.u The user must have Craft Interface Administrator account privileges.

  • 7/29/2019 009-2003-294 Install Test and Turn Up.pdf

    26/300

    INTRODUCTION ONLINE Metro Platform1

    Installation, Turn-up, and Test ManualSeptember 30, 2003 - Revision A

    1 - 2 009-2003-294CIENA CONFIDENTIAL AND PROPRIETARY

    HOW TO USE THIS MANUAL

    This manual is organized into five sections that contain the turn-up and test procedures for the standardconfigurations of ONLINE Metro Platform systems. Each section contains the required tasks to performrelated procedures, and each task contains the required step-by-step procedures to perform that task. Theturn-up and test procedures contained in this manual are organized as follows:

    u Chapter 1 - Introductionu Chapter 2 - Site Preparationu Chapter 3 - Shelf and Tray Installationu Chapter 4 - Circuit Pack Installationu Chapter 5 - Cable and Fiber Managementu Chapter 6 - ONLINE Provisioningu Chapter 7 - Verification Procedures

    BEFORE STARTING

    Before the turn-up and test of an ONLINE Metro Platform system can be performed, an assortment of site-specific/route-specific information must be provided, and the system racks/cabinets must be installed. Thefollowing sections provide a brief overview of the site survey to system acceptance flow of a ONLINE MetroPlatform system.

    Site Survey Overview

    Prior to the installation and turn-up of any ONLINE Metro Platform system, information about the facility andfiber plant is required to properly configure the ONLINE Metro Platform system. The site survey allows thesite survey engineer to analyze the customer site to identify the materials and procedures required for installation. The site survey engineer collects the detailed information used to generate the InstallationSpecification, Recommended Tools and Equipment List, and List of Materials (LOM). The informationcollected during the site survey is also used by the CIENA System Engineer (SE) to generate a DCM

    Connectivity Report for the system configurations containing 10G channels. After the site survey, theinstallation procedures are performed before the System turn-up and test procedures. In addition to the fiber plant information, other facility information (i.e., space, power, grounding, and environmental data) is alsogathered. The site survey engineer develops a Job Specification Package (JSP) that contains the followinginstallation documents:

    u Installation Specificationu Tools and Equipment Listu List of Materials (LOM)u Site Specific Turn-up Report

  • 7/29/2019 009-2003-294 Install Test and Turn Up.pdf

    27/300

    Installation, Turn-up, and Test ManualSeptember 30, 2003 - Revision A009-2003-294 1 - 3

    CIENA CONFIDENTIAL AND PROPRIETARY

    ONLINE Metro Platform INTRODUCTION1

    GENERAL SAFETY PRECAUTIONS

    To avoid injury and/or damage to the equipment, the user must adhere to the following precautions as wellas to the safety procedures established by the organization in which the system is installed. Refer to CIENAStandard Cleaning and Equipment Safety Practices, Document 009-2003-121, Rev 001 for CIENArecommended safety practices.

    Voltage Precaution

    Voltage of -48 VDC is present within the ONLINE Metro Platform equipment as a power source for normalequipment operation. Voltage of 120 VAC is also present at all facilities for test equipment, tools, andlighting. Personnel should exercise safety precautions when connecting, measuring, and disconnecting allvoltage supply lines.

    The following precautions must be observed to avoid voltage shock.

    u Never use both hands when working on or near a voltage source.u Use the buddy system when working around voltage sources.u Ensure that rescue and first aid equipment is available and accessible.u Remove watches, rings, necklaces, and other conductive devices that might come in contact

    with live voltages.u Ensure that other personnel are not in contact with voltage sources before activating circuits.u Deactivate power whenever possible before performing maintenance on system components.

    General Static Electricity Precautions

    A damaging static electricity charge can be generated by the rubbing and sliding of materials against eachother. Different materials have different potentials of generating and holding a static electric charge. Plasticmaterials similar to nylon and polyester are capable of generating and holding a potentially large damagingstatic electricity charge, and materials similar to cotton do not typically have the potential to generate andhold a charge. The buildup of static electricity can be of a sufficient potential to damage electronic circuitry.When working on CIENA equipment or any interconnecting electrical/optical cabling, the user must alwayswear an approved personnel ground device.

    Industry experience has shown that all integrated circuit packs can be damaged by static electricity thatbuilds up on work surfaces and personnel. The effect of ESD damage may be immediate failure or it maymanifest itself as a latent failure affecting the reliability of the equipment.

    Warning:

    RISK OF PERSONAL INJURY

    Negative 48 volts DC is present in the equipment. Contact can causepersonal injury. Take appropriate safety precautions.

    Caution:

    Risk of Damage to Circuit Packs and Backplanes

    This equipment contains Electrostatic Discharge (ESD) sensitivedevices. Wear grounding straps when handling equipment and followESD procedures.

  • 7/29/2019 009-2003-294 Install Test and Turn Up.pdf

    28/300

    INTRODUCTION ONLINE Metro Platform1

    Installation, Turn-up, and Test ManualSeptember 30, 2003 - Revision A

    1 - 4 009-2003-294CIENA CONFIDENTIAL AND PROPRIETARY

    The static charges and discharges are produced by various charging effects of movement and contact withother objects. Dry air allows greater static charges to accumulate on a body.

    The following precautions must be observed to avoid static charges and discharges.

    u Assume that all circuit packs contain solid state electronic components that can be damagedby ESD.

    u When handling circuit packs (e.g., storing, installing, removing, etc.) or when working on thebackplane, always wear a grounded wrist strap or wear a heel strap and stand on a grounded,static-dissipating floor mat.

    u Handle all circuit packs by the faceplate or latch and by the top and bottom outermost edges.Never touch the components, conductors, or connector pins.

    u Observe all warning labels on bags and cartons. If possible, do not remove circuit packs fromantistatic packaging until ready for use.

    u If possible, open all circuit packs at a static-safe work station using properly grounded wriststraps and static-dissipating table mats.

    u Always store and transport circuit packs in static-safe packaging.u Keep all static-generating material, such as food wrappers, plastics, and styrofoam containers,

    away from all circuit packs.u When removing circuit packs from an enclosure, immediately place them in static-safe

    packages.u Whenever possible, maintain a relative humidity above 20 percent.

    General Laser Precautions

    All CIENA Dense Wavelength Division Multiplexing (DWDM) products use infrared light energy to transmitand receive signals between the circuit packs contained within the system and to interface the circuit packsin the system with the external fiber plant and client equipment. The transmission of infrared light energybetween the circuit packs, fiber plant, and client equipment is performed by fiber cables. The infrared lightenergy used in CIENA products falls within the invisible portion of the electromagnetic spectrum. Thisenergy is of sufficient magnitude to cause eye injury with indirect exposure and/or skin injury with directexposure. When working with CIENA equipment, the following general laser precautions must be observed.

    u An operator/technician should not perform work on the system before satisfactorily completingan approved training course.u Only authorized trained personnel should be permitted to perform service, maintenance, and

    restoration.u Never disconnect a lightwave cable and look into the optical connector.u Exercise caution to avoid indirect eye exposure or direct skin exposure to unprotected optical

    connectors.

    Warning:

    LASER RADIATIONAVOID EXPOSURE TO BEAMCLASS 3B LASER PRODUCT

    Laser emissions may cause eye damage. Never look directly into fiber connectors. Always assume that laser radiation is present even whenequipment is turned off.

  • 7/29/2019 009-2003-294 Install Test and Turn Up.pdf

    29/300

    Installation, Turn-up, and Test ManualSeptember 30, 2003 - Revision A009-2003-294 1 - 5

    CIENA CONFIDENTIAL AND PROPRIETARY

    ONLINE Metro Platform INTRODUCTION1

    u Wear laser safety goggles whenever in close proximity to lasers.u Protective covers/caps must be installed on all optical connectors when not in use.u Because laser energy is invisible, always assume that exp