4
Cornerstone Site ID Caesar Site ID Companero Site ID 3493 41041 36379 Existing Vodafone 2G and 3G antennas on tripod support frame. Existing Vodafone 2G and 3G. 270' antennas on tripod support frame, Existing 3 antenna on tripod support frame support frame. Existing T-Uobile antenna on tripod support frame support frame. Existing T-Mobile antenna on tripod support frame support frame. Existing roof access ladder Existing non-slip walkway Existing T-Mobile 300mm wide cable tray. Existing Vodafone Ericsson RBS 2106 cabinet, Ericsson RBS 3101 cabinet and distribution board fixed to supporting steel on concrete stabs. Existing Vodafone 300mm wide cable tray. Existing 3' 450mm wide cable tray. Existing OPCS equipment cabin and stub tower with 6No antennas and INo dish on steel support grillage. Existing Vodafone power cable rising up building from internal room to cabinet location. Existing 3 equipment cabinet. Existing 3 antenna on tripod support frame support frame. Existing T-Mobi!e antenna on tripod support frame support frame. Existing 3 antenna on tripod support frame support frame. PLANNINGLM 1 5 OCT 2009 Existing Vodafone 2G and 3G antennas and INo 300mm DIA Dish on tripod support frame. Existing 2No T-Mobile equipment cabinets on spreader platform. This drawing complies with the latest issue of Vodafone documentation "HaSP 450" and "NRCS/GUIDE/26". EXISTING SITE PLAN (Scale 1:250) GENERAL NOTES Use written dimensions only, do not scale from drawing. Use latest revision of all referenced information. EXISTING VODAFQNE CABINET DETAILS: Ref : 1No. Ericsson RBS2106 cabinet Dimensions : 1300 L x 940 B x 1614 H Material : Steel Colour : Grey (RAL 7035) Ref : INo. Ericsson RBS 3101 cabinet Dimensions : 1300 L x 940 B x 1614 H Material : Steel Colour : Grey (RAL 7035) EXISTING POWER SUPPLY ROUTE: Power supply taken from Vodafone Distribution Board. NOTE: For all matters relating to Local Authority Planning please contact: Keith Johnson Mono Consultants Tel: 0161 839 8839 Rev Dote Description Drawn Chkd MONO CONSULTANTS LIMITED Packvraod House Guild Street Stratford-upon-Avon t. 44 (0)1789 290099 f. 44 (0)1789 290088 *ww.mon oconsu I ton ts. com (Dvodafone Drawing Status PLANNING Cell No. it Option Name 36379A - THEGOSHEN CENTRE Site Nome & Address PLYMOUTH COLLEGE OF FURTHER EDUCATION, THE GOSHEN CENTRE, SALTASH ROAD, PLYMOUTH, PL2 2DP. Drawing Title EXISTING SITE PLAN Scale AS SHOWN Oote Drawn By CY 13.10.09 Checked By SRR Drawing Number 36379/A/002 CAD REF : ORIGINAL DRAWING SIZE A3

description

aa

Transcript of 0000E0DD

  • Cornerstone Site IDCaesar Site IDCompanero Site ID

    34934104136379

    Existing Vodafone 2G and 3Gantennas on tripod support frame.

    Existing Vodafone 2G and 3G.

    270'

    antennas on tripod support frame,Existing 3 antenna on tripodsupport frame support frame. Existing T-Uobile antenna on tripod

    support frame support frame.Existing T-Mobile antenna on tripodsupport frame support frame.

    Existing roof access ladder

    Existing non-slip walkwayExisting T-Mobile300mm wide cable tray. Existing Vodafone Ericsson RBS 2106

    cabinet, Ericsson RBS 3101 cabinetand distribution board fixed tosupporting steel on concrete stabs.

    Existing Vodafone300mm wide cable tray.

    Existing 3' 450mmwide cable tray.

    Existing OPCS equipment cabin andstub tower with 6No antennas andINo dish on steel support grillage.

    Existing Vodafone power cablerising up building from internalroom to cabinet location.

    Existing 3 equipment cabinet. Existing 3 antenna on tripodsupport frame support frame.

    Existing T-Mobi!e antenna on tripodsupport frame support frame.

    Existing 3 antenna on tripodsupport frame support frame.

    PLANNING LM

    1 5 OCT 2009

    Existing Vodafone 2G and 3Gantennas and INo 300mm DIADish on tripod support frame.Existing 2No T-Mobile equipmentcabinets on spreader platform.

    This drawing complies with the latestissue of Vodafone documentation"HaSP 450" and "NRCS/GUIDE/26".

    EXISTING SITE PLAN(Scale 1:250)

    GENERAL NOTES

    Use written dimensions only, do notscale from drawing. Use latestrevision of all referenced information.

    EXISTING VODAFQNE CABINET DETAILS:

    Ref : 1No. Ericsson RBS 2106 cabinetDimensions : 1300 L x 940 B x 1614 HMaterial : SteelColour : Grey (RAL 7035)

    Ref : INo. Ericsson RBS 3101 cabinetDimensions : 1300 L x 940 B x 1614 HMaterial : SteelColour : Grey (RAL 7035)EXISTING POWER SUPPLY ROUTE:

    Power supply taken from Vodafone Distribution Board.

    NOTE:For all matters relating to LocalAuthority Planning please contact:Keith JohnsonMono ConsultantsTel: 0161 839 8839

    Rev Dote Description Drawn Chkd

    MONO CONSULTANTS LIMITEDPackvraod HouseGuild StreetStratford-upon-A von

    t. 44 (0)1789 290099f. 44 (0)1789 290088*ww.mon oconsu I ton ts. com

    (DvodafoneDrawing Status

    PLANNINGCell No. it Option Name

    36379A - THE GOSHEN CENTRE

    Site Nome & Address

    PLYMOUTH COLLEGE OF FURTHEREDUCATION, THE GOSHEN CENTRE,SALTASH ROAD,PLYMOUTH, PL2 2DP.Drawing Title

    EXISTING SITE PLAN

    Scale AS SHOWN Oote

    Drawn By CY

    13.10.09

    Checked By SRR

    Drawing Number

    36379/A/002CAD REF : ORIGINAL DRAWING SIZE A3

  • Cornerstone Site IDCaesar Site IDCompanero Site ID

    34934104136379

    Note:Existing Vodafone 2No 2G LDF5-50 feeders to 270'sector to be replaced with new 2No HFC-42 feeders.

    .Existing Vodofone 2G and 3G antennas on tripodsupport frame. Existing Vodafone 2G antenna tobe removed and replaced with proposedVodafone 2G/3G antenna. Existing Vodafone 3Gantenna to be taken over by Telefonica 02.

    Existing '3' antenna on tripodsupport frame support frame.

    Note:Existing Vodafone 3G feeders to be disconnectedfrom RBS 3101 cabinet and connected to Telefonica02 Flexi BTS 3G cabinet. Existing Vodafone 6No 2Gfeeders to be diplexed for 2G/3G ports of Dual-Bondantennas. Proposed Vodafone diplexers c/w shelf tobe fitted below existing 2106 cabinet in new skid.

    Existing Vodafone 2G and 3G antennas on tripod-support frame. Existing Vodafone 2G antenna tobe removed and replaced with proposedVodafone 2G/3G antenna. Existing Vodafone 3Gantenna to be taken over by Telefonica 02.

    Existing T-Mobile antenna on tripod-support frame support frame.

    270'

    Existing T-Mobile antenna on tripodsupport frame support frame.

    Existing roof access ladder.

    Existing non-slip walkway.

    Existing Vodafone Ericsson RBS 2106 cabinet,Ericsson RBS 3101 cabinet and distribution boardfixed to supporting steel on concrete slabs. ProposedTelefonica 02 Flexi BTS installed within FCOA cabinetbetween existing Vodafone cabinets. Additional steeltrimmers required to suit new cabinet.

    Existing T-Mobile300mm wide cable tray

    Existing Vodafone300mm wide cable tray,

    Existing '3' 450mmwide cable tray.

    Existing OPCS equipment cabin andstub tower with 6No antennas and1No dish on steel support grillage.

    Existing Vodafone power cablerising up building from internalroom to cabinet location.

    Existing '3' equipment cabinet. Existing '3' antenna on tripodsupport frame support frame.

    Existing '3' antenna on tripodsupport frame support frame.

    Existing T-Mobile antenna on tripodsupport frame support frame.

    Existing Vodafone 2G and 3G antennas and INo300mm DIA Dish on tripod support frame. ExistingVodafone 2G antenna to be removed and replaced withproposed Vodafone 2G/3G antenna. Existing Vodafone3G antenna to be taken over by Telefonica 02.

    Note:Proposed Telefonica 02 power from existingVodofone rooftop distribution board (subjectto power survey).

    Proposed Telefonica 02 transmission viaexisting Vodofone dish link (TBC by Vodafone). Existing 2No T-Mobile equipmentcabinets on spreader platform.

    This drawing complies with the latestissue of Vodafone documentation"HaSP 450" and "NRCS/GUIDE/26".

    PROPOSED SITE PLAN(Scale 1:250}

    Information on Significant Residual RisksConstruction

    On the basis of information available tothe designer at the time of designproduction, there are no unusual,unobvious or difficult to managesignificant risks associated with this design

    Maintenance

    On the basis of information available tothe designer at the time of designproduction, there are no unusual,unobvious or difficult to managesignificant risks associated with this design

    Decommissioning

    On the basis of information available tothe designer at the time of designproduction, there are no unusual,unobvious or difficult to managesignificant risks associated with this design

    GENERAL NOTES

    Use written dimensions only, do notscale from drawing. Use latestrevision of all referenced information.

    PROPOSED TELEFONICA 02 CABINET DETAILS:

    Ref : INo. Nokia Flexi FCOA cabinetDimensions : 770 L x 770 B x 1550 HMaterial : SteeiColour : Grey (RAL 7035)PROPOSED POWER SUPPLY ROUTE:

    Power supply taken from Vodafone Distribution Board.

    CITY OF PLVMOuTnPLANNING DEPARTMENT

    1 6 O C T

    PLAN SUBMISSION DATE

    NOTE:For all matters relating to LocalAuthority Planning please contact:Keith JohnsonMono ConsultantsTel: 0161 839 8839

    Rev Dote Description Drawn Chkd

    monoMONO CONSULTANTS LIMITEDPock wood HouseGuild StreetStra tford- u pon - AvonCV37 6RPt. 44 (0)1789 290099f. 44 (0)1789 290088www.monoconsultonts.coin

    vodafoneDrawing Status

    PLANNINGCell No. k Option Name

    36379A - THE GOSHEN CENTRE

    Site Nome tc Address

    PLYMOUTH COLLEGE OF FURTHEREDUCATION, THE GOSHEN CENTRE,SALTASH ROAD,PLYMOUTH, PL2 2DP.Drawing Title

    PROPOSED SITE PLAN

    Scale AS SHOWN

    Drawn By CY

    13.10.09

    Checked By SRR

    Drawing Number

    36379/A/003Revision

    CAD REF : ORIGINAL DRAWING SZE A3

  • Existing Vodafone 3G antennaCell 1A at 30' to be tokenover by Telefonica 02.

    Existing Vodafone 2G antennaCell 1 at 30' to be removed.

    Proposed Telefonica 02 3Gantenna Cell 1A at 30'.

    SECTOR 1

    Proposed Vodafone 2G/3Gantenna Cell 1 at 30'.

    NOTE:For all matters relating to LocalAuthority Planning please contact:Keith JohnsonMono ConsultantsTel: 0161 839 8839

    (SECTOR

    CITY OF PLYMGuTHPLANNING DEPARTMENT

    1 6 uCT

    PLAN SUBMISSION DATE

    (SECTOR 2) (SECTOR 2)

    \ Existing Vodafone 3G antennaCell 2A at 150' to be taken

    Existing Vodafone 2G antenna over b Te|efonica 02.

    Cell 2 at 150 to be removed.Proposed Vodafone 2G/3Gantenna Cell 2 ot 150'.

    Proposed Telefonica 02 3Gantenna Cell 2A at 150'.

    Existing Vodafone 2G antennaCell 3 at 270' to be removed.

    Existing Vodafone 3G antennaCell 3A at 270' to be takenover by Telefonica 02.

    (SECTOR 3)

    Proposed Vodafone 2G/3Gantenna Ceil 3 at 270'.

    Proposed Telefonica 02 3Gantenna Cell 3A at 270'.

    Note:Existing Vodafone 2No 2G LOF5-50 feeders to 270'sector to be replaced with new 2No HFC-42 feeders.

    (SECTOR 3)

    EXISTING VODAFONE ANTENNA PLANSAT 19.40m AGL

    This drawing complies with the latestissue of Vodafone documentation"HaSP 450" and "NRCS/GUIDE/26".

    (Scale 1:50)

    PROPOSED VODAFONE ANTENNAPLANS AT 19.40m AGL

    (Scale 1:50)

    Proposed Telefonica 02 Antenna Schedule

    Cell1A

    2A

    3A

    Description

    305-354305-354305-354

    Func.

    3G3G

    Ht.

    19.4m19.4m19.4m 270'

    Brg

    30'150'

    FeedersType L'gth

    LDF7-50LDF5-50LDF6-50

    70m25m

    45mBearings to EGN. Height measured to base of antenna.Feeder lengths shown are approximate.

    GENERAL NOTES

    Use written dimensions only, do notscale from drawing. Use latestrevision of oil referenced information.

    Existing Vodafone Antenna/Dish Schedule

    Cell

    1A

    2A2'

    3A3*

    Description

    305-354305-017305-354305-017305-354305-017

    Func.

    3G2G3G2G3G2G

    Ht.

    19.4m19.4m19.4m19.4m19.4m19.4m 270"

    Brg

    30'30'150'150'270'

    FeedersType L'gth

    LDF7-50LDF7-50LDF5-50LDF5-50LDF6-50LDF5-50

    70m70m25m

    25m

    45m

    45mAntenna marked thus * are to be removed.

    Existing Vodafone Dish Schedule

    Dish Description

    300mm DIA

    Func. Ht.

    18.9m

    Brg

    TBC

    FeedersType L'gth

    EXISTING 25m

    Proposed Vodafone Antenna Schedule

    Cell Description

    801-664

    801-664801-664

    Func.

    2G/3G2G/3G

    Ht.

    19.4m19.4m

    2G/3G 19.4m 270'

    Brg

    30'ISO-

    FeedersType L'gth

    LDF7-50LOF5-50HFC-42

    70m25m

    45mBearings to EGN. Height measured to base of Antenna &centre of Dish. Feeder lengths shown are approximate.

    Description Drawn Chkd

    . .

    It

    MONO CONSULTANTS LIMITEDPockwood HouseGuild StreetStratford- upon- Avon

    t. 44 (0)1789 290099f. 44 (0)1789 290088www.monoconsultonts.cofn

    vodafoneDrawing Status

    PLANNINGCell No. & Option Name

    36379A - THE GOSHEN CENTRE

    Site Name i Address

    PLYMOUTH COLLEGE OF FURTHEREDUCATION, THE GOSHEN CENTRE,SALTASH ROAD,PLYMOUTH, PL2 2DP.Drawing Tltla

    ANTENNA DETAILS

    Scale AS SHOWN

    Drawn By CY

    Date 13.10.09

    Checked By SRR

    Drawing Number

    36379/A/006CAD REF : ORIGINAL DRAWING SIZE A3

  • VODAFONE S1GNAGE DETAILS

    Sign TypeSign

    Description

    Site Entry Sign

    Antenna RFWarning Sign

    Quantity

    43

    SignLocation

    On roof accessladder

    2No. onaccessable

    front/side/backof the antennas

    Part No.

    305-428(Upper;305-435(Lower)

    800-334

    Cornerstone Site ID

    Caesar Site ID

    Componero Site ID

    349341041

    36379

    This drawing complies with the latestissue of Vodafone documentation"HaSP 450" and "NRCS/GUIDE/26".

    PROPOSED SIGNAGE DETAILS(Scale 1:250)

    GENERAL NOTES

    Use written dimensions only, do notscale from drawing. Use latestrevision of all referenced information.

    NOTES

    1) For details of sign layout, dimensions etc... seeVodafone document HaSP 450 - "RadioFrequency Safety Signaqe at Radio Base Stations"

    CITY OF P, -.'MuuTHPLANNING DEPARTMENT

    PLAN SUBMISSION DATE

    NOTE:For all matters relating to LocalAuthority Planning please contact:Keith JohnsonMono ConsultantsTel: 0161 839 8839

    Rev Date Description Drown Chkd

    MONO CONSULTANTS LIMITEDPackwood HouseGuild StreetStratford-upon-Avon

    1.44(0)1789290099f. 44 (0)1789 290088www.monoconsultants.com

    vodafoneDrawing Status

    PLANNINGCeil No. & Option Nome

    36379A - THE GOSHEN CENTRE

    Site Nome 4 Address

    PLYMOUTH COLLEGE OF FURTHEREDUCATION, THE GOSHEN CENTRE,SALTASH ROAD,PLYMOUTH, PL2 2DP.Drawing Tltla

    SIGNAGE DETAILS

    Scale AS SHOWN

    Drown By CY

    Data 13.10.09

    Chocked By SRR

    Drowing Number

    36379/A/007CAD REF ORIGINAL DRAWING SIZE A3