© ZigBee Alliance. All rights reserved. 1 ERL for Linky Smart Meter Vincent ILLIONNET...
-
Upload
collin-norris -
Category
Documents
-
view
226 -
download
2
Transcript of © ZigBee Alliance. All rights reserved. 1 ERL for Linky Smart Meter Vincent ILLIONNET...
© ZigBee Alliance. All rights reserved. 1
ERL for Linky Smart Meter
Vincent [email protected]
Doc 14-0463-00
CONFIDENTIAL 14-0463-00© ZigBee Alliance. All rights reserved. 2
Who are we ?
EDF, a french Utility, ERDF the french DNO
IGNES, an Industrial syndicate representative of In House electric appliances' and CEMS in the French market
Smart Electric Lyon, a project for ensure strong interoperability between Smart Meter and electric appliances
CONFIDENTIAL 14-0463-00© ZigBee Alliance. All rights reserved. 3
Who are we ?
IGNES MEMBERS
CONFIDENTIAL 14-0463-00© ZigBee Alliance. All rights reserved.
Who are we ?
Smart Electric Lyon’s Partners
CONFIDENTIAL 14-0463-00© ZigBee Alliance. All rights reserved. 5
Electomecanical meter – CBME = Compteur Bleu Electromecanique
• Around 22 Million meters
Electronic meter – CBE = Compteur Bleu Electronique
• More than 10 million meters
All residential EDF meters using at least a dual tarification are controlled by a unidirectional 175 Hz signal over the power line since 70’s
Example : Today, 10 million electric water tanks are switch on during the night to allow a flat load curve in order to optimize nuclear generation.
ERDF CBME and CBE Meters
CONFIDENTIAL 14-0463-00© ZigBee Alliance. All rights reserved. 6
Currently 114 Meters in 6 different families
CONFIDENTIAL 14-0463-00© ZigBee Alliance. All rights reserved. 7
Linky – Field test
• 300 000 meters already deployed
– Smart Electric Lyon field test is done during the first Linky deployment phase
• Linky Meter deployment starts in 2015
– Generalization phase• Will start in 2015
– With 3 million meters for the first Year
• Then– Deployment of the 32 million meters – End of deployment schedule for 2020/2022.
ERDF Linky Smart Meter
CONFIDENTIAL 14-0463-00© ZigBee Alliance. All rights reserved. 8
Quick descrition : TIC– Is a real time serial and modulated wired Interface
• 1 to 3 seconds instantaneous emission• Supplied by the meter (130mW +/- 8V AC 50 KHz)
– Two TIC modes are available• Historical mode (1200 Bps)
– For historical tarification calendar» Allows retro compatibility with “Old” Customer appliances
• Standard Mode (9600 Bps)– For new tarification calendar
» Allows a more flexible and dynamical tarification for all french electricity providers
Linky Downstream Interface
CONFIDENTIAL 14-0463-00© ZigBee Alliance. All rights reserved. 9
Historical TIC to ZCL mapping example for a « Tempo » EDF
contract
CONFIDENTIAL 14-0463-00© ZigBee Alliance. All rights reserved. 10
Historical TIC data example for a « Tempo » EDF contract
CONFIDENTIAL 14-0463-00© ZigBee Alliance. All rights reserved. 11
Third quarter 2014 : ERL specification available
First quarter 2015 : first prototype available for functional validation for SEL’s member
Third quarter 2015 : development kit available for SEL’s Member
ERL development Schedule
CONFIDENTIAL 14-0463-00© ZigBee Alliance. All rights reserved. 1212
Reminder : ERL is not a SE1.x device
It must follows Interop and will use Red Z Logo
ZigBee Interop for ERL
CONFIDENTIAL 14-0463-00© ZigBee Alliance. All rights reserved. 13
Use cases Architecture : Today
13
CONFIDENTIAL 14-0463-00© ZigBee Alliance. All rights reserved. 1414
Use cases Architecture : Today
14
WATER
HEATER
WATER
HEATER
Electricity Heating
Management System
Electricity Heating
Management System
Wired
Tomorrow
Electric Heaters Wired
Wired data link (TIC)
CONFIDENTIAL 14-0463-00© ZigBee Alliance. All rights reserved. 1515
Use cases Architecture : Tomorrow
15
WATER
HEATER
WATER
HEATER
Electricity Heating
Management System
Electricity Heating
Management System
Wired data link (TIC)
Wired
ERLERL
SMART
DISPLAY
SMART
DISPLAY
Electric Heaters Wired
CONFIDENTIAL 14-0463-00© ZigBee Alliance. All rights reserved. 16
ON/OFF
Output
device
ON/OFF
Output
device
WATER
HEATER
ON/OFF Output
WATER
HEATER
ON/OFF Output
SMART
DISPLAY
SMART
DISPLAY
ERLERL
Electricity Heating
Management System
Electricity Heating
Management System Electric Heaters
Wired
Wired
Use cases Architecture : Tomorrow
CONFIDENTIAL 14-0463-00© ZigBee Alliance. All rights reserved. 1717
ON/OFF
Output
device
ON/OFF
Output
device
ON/OFF
Output
device
ON/OFF
Output
deviceWATER
HEATER
ON/OFF Output
WATER
HEATER
ON/OFF Output
SMART
DISPLAY
SMART
DISPLAY
ERLERL
Electricity Heating
Management System
Electricity Heating
Management System Electric Heaters
Wired
Use cases Architecture : Tomorrow
CONFIDENTIAL 14-0463-00© ZigBee Alliance. All rights reserved. 181818
Use cases Architecture : Tomorrow
18
Electricity Heat PumpElectricity Heat Pump
SMART
DISPLAY
SMART
DISPLAY
ERLERL
Temperature
Sensor
Temperature
Sensor
CONFIDENTIAL 14-0463-00© ZigBee Alliance. All rights reserved. 1919
SMART
DISPLAY
SMART
DISPLAY
ERLERL
Use cases Architecture : Tomorrow
CONFIDENTIAL 14-0463-00© ZigBee Alliance. All rights reserved. 20202020
EV Charger
EV Charger
ON/OFF
Output
device
ON/OFF
Output
device
ERLERL SMART
DISPLAY
SMART
DISPLAY
Electricity Heating
Management System
Electricity Heating
Management System Electric Heaters
Wired
Electric Heaters PV
productionPV
productionERLERL
Use cases Architecture : Tomorrow
WATER
HEATER
ON/OFF Output
WATER
HEATER
ON/OFF Output
CONFIDENTIAL 14-0463-00© ZigBee Alliance. All rights reserved. 2121212121
ERLERL
EZ-Mode Provisionning Use Cases example
UC 1 : CommissioningTo invoke the EZ-Mode Commissioning the user use a remote control provided with ERL(out of band 2,4 Ghz) because the ERL has no MMI.
868 Remote Control
868 Remote Control
CONFIDENTIAL 14-0463-00© ZigBee Alliance. All rights reserved. 222222222222
ERLERL
Energy display Use case example
UC 2 : A display read HCHC (CurrentTier1SummationDelivered)The display sends read attribut (CurrentTier1SummationDelivered) to ERL and display the response.
SMART
DISPLAY
SMART
DISPLAY
CONFIDENTIAL 14-0463-00© ZigBee Alliance. All rights reserved. 23232323232323
ERLERL
Power suscription limitation management Use Case example
UC3 : A energy manager wants to be warned when current (IINST) exceeds the limit current (ISOUSC)
It can controls electric Heaters one by one and reduces Energy consumption to allow consumer to susbribe cheaper contract (9KVA instead of 12 KVA as an example)
Electricity Heating
Management System
Electricity Heating
Management System Electric Heaters
Wired
CONFIDENTIAL 14-0463-00© ZigBee Alliance. All rights reserved. 2424242424242424
ERLERL
UC4 : An Electric Water tank is switch On only during Lowest Price Time slot, eg : when CurrentTier1SummationDelivered is used.
WATER
HEATER
ON/OFF Output
WATER
HEATER
ON/OFF Output
Electric Water tank Use Cases example
CONFIDENTIAL 14-0463-00© ZigBee Alliance. All rights reserved. 2525252525252525
ERLERL
CEMS Use Cases example
UC5 : A energy manager wants to know tomorrow ‘s day profile.
It can controls electric Heaters and decides to change tomorrow heating schedule according to tomorrow day profile and Customer preferences.
Electricity Heating
Management System
Electricity Heating
Management System Electric Heaters
Wired
CONFIDENTIAL 14-0463-00© ZigBee Alliance. All rights reserved. 26262626
ERLERL
PV Production Use Cases example
PV production
PV production
ERLERLUC6 : Smart Display wants to know yesterday energy production and compare it with yesterday energy comsumption.
After Midnight (from 00:00 to 00:10) Smart Smart display asks for : -CurrentSummationDelivered (ERL1)
and - CurrentSummationReceived (ERL 2).
SMART
DISPLAY
SMART
DISPLAY
CONFIDENTIAL 14-0463-00© ZigBee Alliance. All rights reserved. 2727272727
EV Charger
EV Charger
ERLERL
EV charger Use Cases example
UC7 : Electric Car wants to be ready to use tommorow morning at 08AM.
EV Charger wants to charge at an optimum cost, If it doesn’t know tommorrow day profile it asks for it : (PJOURF+1) Else it asks for number of the day profile (NJOURF+1) and number of the tomorrow day profile (NJOURF+1)
CONFIDENTIAL 14-0463-00© ZigBee Alliance. All rights reserved. 282828282828
ERLERL
And so on …
UCX :…
UCY : ….
CONFIDENTIAL 14-0463-00© ZigBee Alliance. All rights reserved.
Since Vancouver:
– ERL Linky TIC to ZCL mapping interface proposal according to PRO Energy recommandation in Vancouver :
– See document 14-0464-00
29
© ZigBee Alliance. All rights reserved. www.zigbee.org
© ZigBee Alliance. All rights reserved. www.zigbee.org
Thanks