Door Hardware 087100-1 CTC08131 Nursing and Classroom Building

087100 DOOR HARDWARE

1.00 GENERAL

1.01 SUMMARY

A. Section Includes: Furnish and deliver all items of finish hardware required to adequately trim and hang all doors, as is hereinafter specified and listed in the hardware sets. This further includes hardware for doors and frames of unusual profile or shape or other special conditions. Hardware shall be provided with all necessary standard and special fasteners, screws, bolts, expansion shields or anchors to properly secure hardware to its intended door, frame or other surface.

B. Related Sections: Other Sections within this specification which relate to products supplied and installed under finish hardware are as follows, but not limited to:

1. Hollow Metal Doors and frames Section 081113 2. Flush Wood Doors Section 081416 3. Glazed Aluminum Curtain Wall Section 084413

1.02 REFERENCES A. The following documents should be used in estimating and detailing and considered as a

standard of quality and performance, if applicable: 1. I.B.C. Current year adopted. 2. NFPA-80 Fire Doors & Windows (current year adopted). 3. NFPA-101 Life Safety Code (current year adopted). 4. NFPA-105 Smoke Control Door Assembly. (current year adopted) 5. ANSI-117.1 1992 Edition Providing Accessibility and Usability for Physically

Handicapped People. 6. A.D.A.A.G Americans with Disabilities Act Accessibility Guidelines. 7. T.A.S. Texas Accessibility Standards.

1.03 SUBMITTALS

A. General Requirements: Make all submittals in accordance with Section 013000.

B. Door Hardware Schedule: Prepared by or under the supervision of supplier, detailing fabrication and assembly of door hardware, as well as procedures and diagrams. Coordinate the final Door Hardware Schedule with doors, frames, and related work to ensure proper size, thickness, hand, function, and finish of door hardware.

1. Format: Comply with scheduling sequence and vertical format in DHI's "Sequence and Format for the Hardware Schedule."

2. Organization: Organize the Door Hardware Schedule into door hardware sets indicating complete designations of every item required for each door or opening.

3. Content: Include the following information: a. Type, style, function, size, label, hand, and finish of each door hardware item. b. Manufacturer of each item. c. Fastenings and other pertinent information.

Door Hardware 087100-2 CTC08131 Nursing and Classroom Building

d. Location of each door hardware set, cross-referenced to Drawings, both on floor plans and in door and frame schedule.

e. Explanation of abbreviations, symbols, and codes contained in schedule. f. Mounting locations for door hardware. g. Door and frame sizes and materials.

4. Submittal Sequence: Submit the final Door Hardware Schedule at earliest possible date, particularly where approval of the Door Hardware Schedule must precede fabrication of other work that is critical in the Project construction schedule. Include Product Data, Samples, Shop Drawings of other work affected by door hardware, and other information essential to the coordinated review of the Door Hardware Schedule..

C. Product Data: Provide a catalog cut, clearly marked and identified, illustrating and describing each product included in the Hardware Schedule. Formulate these catalog cuts into sets and include a set with each copy of the Hardware Schedule submitted.

D. Samples: If so requested by the Architect, provide a sample of any product or item requested, properly marked and tagged, for the opening for which it is intended.

E. Templates: Provide copies of templates to manufacturers or trades whose work includes preparation of their products to receive hardware.

F. Keying: Provide a keying schedule, listing the levels of keying, (GGMK, GKD, MKD or KA) as well as an explanation of the key system’s function, the key symbols used and the numbers of the doors controlled. Provide in conjunction with the Door Index/Keying Schedule (which lists the door number, schedule heading, lock type and individual key symbol and remarks or special instructions) mentioned in above. Project shall be Masterkeyed and/or Grand Masterkeyed and provide two (2) keys per lockset or cylinder.

G. Operations and Maintenance Data: Provide latest, revised and updated schedule of finish hardware, complete with catalog cuts and keying schedule. In addition, furnish one (1) copy of maintenance and parts manuals for those items for which they are readily available and normally provided. Submit in accordance with provisions of Section 017300.

1.04 QUALITY ASSURANCE

A. Substitutions: Request for substitutions for alternative hardware items will not be accepted on this project. Specification indicates one (1) specified and two (2) acceptable alternative manufacturers’ products listed hereinafter in the Hardware Schedule. If any specified product is listed as a “No Substitution” product, that specified product shall be supplied as specified.

B. Installer Qualifications: An experienced installer who has completed door hardware similar in material, design, and extent to that indicated for this Project and whose work has resulted in construction with a record of successful in-service performance.

C. Supplier Qualifications: Door hardware supplier with warehousing facilities in Project's vicinity and who is or employs a qualified Architectural Hardware Consultant, available during the course of the Work to consult with Contractor, Architect, and Owner about door hardware and keying.

1. The hardware supplier shall be engaged regularly in the furnishing, delivery and servicing of contract builder's hardware and must be experienced and knowledgeable in all phases of estimating, detailing, scheduling, masterkeying, shipping and installation practices.

2. When electro-mechanical or electronic hardware is supplied, a qualified individual with a minimum five- (5) year’s experience shall be available for assistance.

Door Hardware 087100-3 CTC08131 Nursing and Classroom Building

D. Architectural Hardware Consultant Qualifications: A person who is currently certified by the Door and Hardware Institute as an Architectural Hardware Consultant and who is experienced in providing consulting services for door hardware installations that are comparable in material, design, and extent to that indicated for this Project.

E. Source Limitations: Obtain each type and variety of door hardware from a single manufacturer, unless otherwise indicated.

F. Regulatory Requirements: Comply with provisions of the following:

1. Where indicated to comply with accessibility requirements, comply with Americans with Disabilities Act (ADA), "Accessibility Guidelines for Buildings and Facilities (ADAAG)," and ANSI A117.1.

G. Fire-Rated Door Assemblies: Provide door hardware for assemblies complying with NFPA 80 that are listed and labeled by a testing and inspecting agency acceptable to authorities having jurisdiction, for fire ratings indicated, based on testing according to NFPA 252.

H. Keying Conference: Conduct conference at Project site to comply with requirements in Division 1 Section "Project Administration." Incorporate keying conference decisions into final keying schedule after reviewing door hardware keying system including, but not limited to, the following:

1. Function of building, flow of traffic, purpose of each area, degree of security required, and plans for future expansion.

2. Preliminary key system schematic diagram. 3. Requirements for key control system. 4. Address for delivery of keys. 5. Location of Key Cabinet.

1.05 DELIVERY, STORAGE, AND HANDLING

A. Marking and Packaging: All items of hardware shall be delivered to the jobsite in the manufacturer’s original cartons or boxes. Each item of hardware shall be marked with the abbreviation set forth on the shop drawings to insure that the product reaches its installation destination without needing specific hardware product number knowledge.

B. Inventory door hardware on receipt and provide secure lock-up for door hardware delivered to Project site.

C. Tag each item or package separately with identification related to the final Door Hardware Schedule, and include basic installation instructions with each item or package.

1.06 COORDINATION

A. Templates: Obtain and distribute to the parties involved templates for doors, frames, and other work specified to be factory prepared for installing door hardware. Check Shop Drawings of other work to confirm that adequate provisions are made for locating and installing door hardware to comply with indicated requirements

B. Electrical System Roughing-in: Coordinate layout and installation of electrified door hardware with connections to power supplies.

Door Hardware 087100-4 CTC08131 Nursing and Classroom Building

1.07 MAINTENANCE

A. Maintenance Tools and Instructions: Furnish a complete set of specialized tools and maintenance instructions as needed for Owner's continued adjustment, maintenance, and removal and replacement of door hardware.

B. Maintenance Service: If there are any products listed hereinafter that normally require a maintenance or service contract, provide the Owner and Architect with details and costs of said contract.

2.00 PRODUCTS

2.01 MANUFACTURES

A. Products listed in the following with an asterisk (*) shall denote specified manufacturers in Hardware Schedule. The remaining two (2) listed manufacturers will be acceptable substitutions. If only one manufacturer is listed this shall be considered a “No Substitution” specification, as set forth in “Quality Assurance” Article.

2.02 MATERIALS

A. Screws and Fasteners: Provide all screws and fasteners of the proper size and type to properly anchor or attach the item of hardware scheduled. Provide all fasteners with Phillips heads, unless security type screws (spanner-head or torx-head) are hereinafter specified.

B. Hinges: Where hinges are specified, they shall be as follows:

1. On doors to exterior openings and main corridor doors, and other doors of high frequency use, provide a continuous, gear type hinge of appropriate weight.

2. Where regular ball bearing hinges are listed for other doors, provide one hinge for each 30-inch of door height.

3. The width of the hinges shall be sufficient to clear all trim that is mounted to the doorframe.

4. Hinges shall be guaranteed for life of opening if installed per manufacturer's recommendation.

5. ACCEPTABLE MANUFACTURERS----Ives*, Baldwin, Bommer, Hager.

C. Continuous Hinges: Continuous hinges shall consist of three (3)-interlocking extrusions in a pinless assembly applied to the full height of the door. All continuous geared hinges shall be manufactured to template screw locations and be non-handed. All mortise hinges and half mortise hinges shall cover and wrap the door edge completely. Doorframe heads shall be extended for clearance on full or half mortise hinges versus downsizing doors for ease of repair and replacement. All frames shall be properly reinforced per manufacturer's standards.

1. Standard warranty shall be for the life of opening. 2. ACCEPTABLE MANUFACTURERS----Ives*, Select, Roton, ABH.

D. Locks: All locks shall incorporate with existing MASTER SYSTEM. Keying system must be guaranteed of no duplication of existing change keys, master keys or grandmaster keys located in this project. All keying must be coordinated with architect/owner. All locks shall be Grade 1 cylindrical as is hereinafter listed in the Hardware Schedule.

1. ACCEPTABLE MANUFACTURERS----Corbin-Russwin.

Door Hardware 087100-5 CTC08131 Nursing and Classroom Building

E. Lock Trim: Cylindrical/mortise locks are to be furnished with lever handle trim, with levers having a return to within 1/2 inch of the door face, as is hereinafter listed in the Hardware Schedule.

F. Flush Bolts: Manual flush bolts to have 12-inch rods for doors 7’6”. Doors over 7’6” high shall have bolts with top rods of 18 inch or 24 inch to allow ease of access to bolt lever. Furnish dust proof strikes for all bottom bolts.

1. ACCEPTABLE MANUFACTURERS----Ives*, Trimco, Baldwin, Hager

G. Exit Devices: Exit Devices shall be rim, mortise or vertical rod type as called for in the Hardware Schedule. Devices shall be of the touch-pad type as is hereinafter specified in the Hardware Schedule. Exit devices must be constructed as to allow the cylinder to be removed and rekeyed, without removing the device from the door either by removable core cylinders or construction of exit device. Exit devices must be constructed as to allow the conversion from one function to another simply within lock stile case and selecting proper outside trim as specified hereinafter in the Hardware Schedule. Devices to be furnished with outside trim, which has matching lever handles to locks.

1. ACCEPTABLE MANUFACTURERS----Von Duprin* 99 Series No Substitution.

H. Door Closers: Door closers shall be of rectangular design and furnished with a full cover. They shall be furnished with backcheck, delayed action and hold-open as listed in the Hardware Schedule. Closers shall be mounted out of the line of sight wherever possible (i.e., room side of corridor doors, etc.) with parallel arm mounting on out swinging doors. Mount closers top jamb or on brackets and/or drop plates, where special conditions call for it.

1. ACCEPTABLE MANUFACTURERS----LCN* 4040 series No Substitution.

I. Push Plates: Push plates are to be .050 brass, bronze or stainless steel with four (4) beveled edges, drilled and countersunk for screws, as is hereinafter specified in the Hardware Schedule.

1. ACCEPTABLE MANUFACTURERS----Ives*, Trimco, Baldwin, Hager.

J. Door Pulls: Door pulls to be ADA compliant with a 2 1/2 inch projection from back of pull to face of door. All door pulls to be thru bolted or back to back mounting.

1. ACCEPTABLE MANUFACTURERS----Ives*, Trimco, Baldwin, Hager.

K. Protective Plates: Protective plates shall be mop (6”), kick (10”) or armor (34”) and shall be .050 brass, bronze or stainless steel, with four (4) beveled edges, drilled and countersunk for screws. Plates to be mounted to avoid louvers and/or glass kits. Do not install kick plates on doors scheduled to receive door protection.

1. ACCEPTABLE MANUFACTURERS----Ives*, Trimco, Baldwin, Hager.

L. Door Stops and Holders: Where a door strikes a wall at approximately 90 degrees, a suitable door stop shall be provided, either a wall bumper or floor stop. Where doors are undercut, provide floor stops with adequate height to properly stop the door. If door does not strike a wall, an overhead stop shall be required. Provide proper blocking for wall bumpers at stud walls and in frame and door for overhead stops.

1. ACCEPTABLE MANUFACTURERS----Ives*, ABH, Glynn-Johnson*. Trimco

M. Thresholds and Weatherstrip: Weatherstripping to have aluminum housing and specified insert, and have elongated holes. Door sweeps to be surface mounted of aluminum/stainless steel housing with specified insert. Overhead drip caps to be of aluminum, have a 2 1/2-inch projection and be 4 inches wider than the door opening. Thresholds shall be of saddle type

Door Hardware 087100-6 CTC08131 Nursing and Classroom Building

with no more than 1/2 inch in rise. Weatherstripping and smoke seals must be surface mounted on doorstop and have 1/4" adjustment slots.

1. ACCEPTABLE MANUFACTURERS----NGP*, Reese, Zero, Pemko.

2.03 FINISHES

A. Hardware finishes shall match and be maintained to BHMA symbols, as is specified hereinafter in the Hardware Schedule. Strict adherence to base metals and finish is required.

2.04 KEYING

A. Keying of locks and cylinders throughout project shall be scheduled through a key meeting with Architect, Owner, and hardware supplier. Key schedule shall be prepared and submitted to the Owner for approval. Copies of final key schedule with the bitting instructions shall be submitted as part of the Project Record Documents.

3.00 EXECUTION

3.01 EXAMINATION

A. Examine doors and frames, with Installer present, for compliance with requirements for installation tolerances, labeled fire door assembly construction, wall and floor construction, and other conditions affecting performance.

B. Examine roughing-in for electrical power systems to verify actual locations of wiring connections before electrified door hardware installation.

C. Proceed with installation only after unsatisfactory conditions have been corrected.

3.02 PREPARATION

A. Steel Doors and Frames: Comply with DHI A115 series.

1. Surface-Applied Door Hardware: Drill and tap doors and frames according to SDI 107.

B. Wood Doors: Comply with DHI A115-W series.

3.03 INSTALLATION

A. Installation shall be by a qualified installer with a minimum five- (5) year’s experience in the installation of commercial grade hardware. Manufacturer’s instructions shall dictate templating and installation.

B. Mounting Heights: Mount door hardware units at heights indicated in following applicable publications, unless specifically indicated or required to comply with governing regulations:

1. Standard Steel Doors and Frames: DHI's "Recommended Locations for Architectural Hardware for Standard Steel Doors and Frames."

2. Wood Doors: DHI WDHS.3, "Recommended Locations for Architectural Hardware for Wood Flush Doors.”

C. Install each door hardware item to comply with manufacturer's written instructions. Where cutting and fitting are required to install door hardware onto or into surfaces that are later to be painted or finished in another way, coordinate removal, storage, and reinstallation of

Door Hardware 087100-7 CTC08131 Nursing and Classroom Building

surface protective trim units with finishing work specified in Division 9 Sections. Do not install surface-mounted items until finishes have been completed on substrates involved.

1. Set units level, plumb, and true to line and location. Adjust and reinforce attachment substrates as necessary for proper installation and operation.

2. Drill and countersink units that are not factory prepared for anchorage fasteners. Space fasteners and anchors according to industry standards.

D. Thresholds: Set thresholds for exterior and acoustical doors in full bed of sealant complying with requirements specified in Division 7 Section "Joint Sealants.”

3.04 FIELD QUALITY CONTROL

A. A final inspection shall take place by the hardware installer and hardware supplier to insure correct installation and operation, and check for any damaged or defective items. Observe and inspect that all hardware has been installed to its correct destination in proper working order.

3.05 ADJUSTING

A. Initial Adjustment: Adjust and check each operating item of door hardware and each door to ensure proper operation or function of every unit. Replace units that cannot be adjusted to operate as intended. Adjust door control devices to compensate for final operation of heating and ventilating equipment and to comply with referenced accessibility requirements.

1. Door Closers: Adjust sweep period so that, from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3 inches (75 mm) from the latch, measured to the leading edge of the door.

B. At completion of the installation and before turn over of the project, make final adjustments to door closures and other items of hardware. Leave all hardware clean and fully operable. Should any item be found to be defective, it shall be repaired or replaced as directed.

3.06 CLEANING AND PROTECTION

A. Clean adjacent surfaces soiled by door hardware installation.

B. Clean operating items as necessary to restore proper function and finish.

C. Provide final protection and maintain conditions that ensure door hardware is without damage or deterioration at time of Substantial Completion.

3.07 DEMONSTRATION

A. Engage a factory-authorized service representative to train Owner's maintenance personnel to adjust, operate, and maintain door hardware and door hardware finishes.

3.08 HARDWARE SCHEDULE Hardware Group No. 001 For use on door(s): A119 A119C Provide each door with the following:

Door Hardware 087100-8 CTC08131 Nursing and Classroom Building

Quantity Description Model Number Finish Mfr 1 EA CYLINDER IC CYLINDER W/CONST CORE - TYPE AS REQ 626 C-R 1 EA IC CORE ONLY, KEYED PERMENANT IC CORE - KEYED AS REQ 626 C-R 1 BALANCE OF HARDWARE BY DOOR

MANUFACTURER

Hardware Group No. 002 – 100 – [NOT USED] Hardware Group No. 101 For use on door(s): A112 Provide each SGL door(s) with the following:

Quantity Description Model Number Finish Mfr 3 EA HINGE 5BB1 4.5 X 4.5 (HW @ 3'6" & LGR) 652 IVE 1 EA OFFICE LOCK ML2051 NSA - CONST KEYED 626 C-R 1 EA SURFACE CLOSER 4041 OR P4041 X TB - MOUNT TO SUIT

CONDITIONS 689 LCN

1 EA KICK PLATE 8400 12" X 1-1/2" LDW X B3E 630 IVE 1 EA STOP WS407CCV 626 IVE 1 SET SEALS 5050B BRN NGP

Hardware Group No. 102 – [NOT USED] Hardware Group No. 103 For use on door(s): A202 A203 A204 A205 A206 A207 A208 A209 A210 A211 A214 A215 A216 A217 A218 A219 A220A A220B A224 A225 A226 A227 A228 A229 A233 A241 A242 A243 A246 A247 A248 A249 A250 A251 A252 A253 A254 A255 A138 A138A B106C B106D B106E B106G B106A B106B B208 B209 B210 B211 B106H B207 B214 B215 B216 B219 B212 B213 B222 B223 B224 B225 B220 B221 B228 B229 B230 B231 B226 B227 B238 B239 B240 B241 B232 B236 B244 B245 B246 C103 B242 B243 C119 C121 C122 C123 C105 C107 C128 C129 C130 C132 C124 C127 C138 C143 C145 C135 C137 Provide each SGL door(s) with the following:

Quantity Description Model Number Finish Mfr 3 EA HINGE 5BB1 4.5 X 4.5 (HW @ 3'6" & LGR) 652 IVE 1 EA OFFICE LOCK ML2051 NSA - CONST KEYED 626 C-R 1 EA STOP WS407CCV 626 IVE 1 SET SEALS 5050B BRN NGP

Hardware Group No. 104 – 199 – [NOT USED]

Door Hardware 087100-9 CTC08131 Nursing and Classroom Building

Hardware Group No. 200 For use on door(s): A128 B218 Provide each PR door(s) with the following:

Quantity Description Model Number Finish Mfr 6 EA HINGE 5BB1 4.5 X 4.5 (HW @ 3'6" & LGR) 652 IVE 2 EA SURFACE BOLT SB453-12-TB 626 IVE 1 EA STOREROOM LOCK ML2057 NSA - CONST KEYED (KNURLED @

MECH & ELEC) 626 C-R

1 SET ASTRAGAL 9605A AL NGP 1 EA SURFACE CLOSER 4041 OR P4041 X TB - MOUNT TO SUIT

CONDITIONS 689 LCN

2 EA KICK PLATE 8400 12" X 1" LDW X B3E 630 IVE 2 EA STOP WS407CCV 626 IVE 1 SET SEALS 5050B BRN NGP

Hardware Group No. 200SS For use on door(s): A257 Provide each PR door(s) with the following:

Quantity Description Model Number Finish Mfr 6 EA HINGE 5BB1 4.5 X 4.5 (HW @ 3'6" & LGR) 652 IVE 2 EA SURFACE BOLT SB453-12-TB 626 IVE 1 EA STOREROOM LOCK ML2057 NSA - CONST KEYED (KNURLED @

MECH & ELEC) 626 C-R

1 EA ASTRAGAL 148NA AL NGP 1 EA SURFACE CLOSER 4041 OR P4041 X TB - MOUNT TO SUIT

CONDITIONS 689 LCN

2 EA KICK PLATE 8400 12" X 1" LDW X B3E 630 IVE 2 EA STOP WS407CCV 626 IVE 1 SET SEALS 700SA (MOUNT BEFORE OTHER HARDWARE) AL NGP 2 EA DOOR BOTTOM 422N AL NGP 1 EA THRESHOLD 324/425 AL NGP

Hardware Group No. 201 For use on door(s): A113 A129 A133A A137 A212 A230 A234 A244 B108 B110 B249 B253 B255 C140 Provide each SGL door(s) with the following:

Quantity Description Model Number Finish Mfr 3 EA HINGE 5BB1 4.5 X 4.5 (HW @ 3'6" & LGR) 652 IVE 1 EA STOREROOM LOCK ML2057 NSA - CONST KEYED (KNURLED @

MECH & ELEC) 626 C-R

1 EA SURFACE CLOSER 4041 OR P4041 X TB - MOUNT TO SUIT CONDITIONS

689 LCN

1 EA KICK PLATE 8400 12" X 1-1/2" LDW X B3E 630 IVE 1 EA STOP WS407CCV 626 IVE 1 SET SEALS 5050B BRN NGP

Door Hardware 087100-10 CTC08131 Nursing and Classroom Building

Hardware Group No. 201C For use on door(s): B115 C112 Provide each SGL door(s) with the following:

Quantity Description Model Number Finish Mfr 3 EA HINGE 5BB1 4.5 X 4.5 (HW @ 3'6" & LGR) 652 IVE 1 EA STOREROOM LOCK ML2057 NSA - CONST KEYED (KNURLED @

MECH & ELEC) 626 C-R

1 EA SURFACE CLOSER 4041 SCUSH X TB - MOUNT TO SUIT CONDITIONS

689 LCN

1 EA KICK PLATE 8400 12" X 1-1/2" LDW X B3E 630 IVE 1 EA STOP WS407CCV 626 IVE 1 SET SEALS 5050B BRN NGP

Hardware Group No. 201SS For use on door(s): A258 Provide each SGL door(s) with the following:

Quantity Description Model Number Finish Mfr 3 EA HINGE 5BB1 4.5 X 4.5 (HW @ 3'6" & LGR) 652 IVE 1 EA STOREROOM LOCK ML2057 NSA - CONST KEYED (KNURLED @

MECH & ELEC) 626 C-R

1 EA SURFACE CLOSER 4041 OR P4041 X TB - MOUNT TO SUIT CONDITIONS

689 LCN

1 EA KICK PLATE 8400 12" X 1-1/2" LDW X B3E 630 IVE 1 EA STOP WS407CCV 626 IVE 1 SET SEALS 700SA (MOUNT BEFORE OTHER HARDWARE) AL NGP 1 EA DOOR BOTTOM 422N AL NGP 1 EA THRESHOLD 324/425 AL NGP

Hardware Group No. 202 – 203 – [NOT USED] Hardware Group No. 204C For use on door(s): A141 A143 A119B Provide each PR door(s) with the following:

Quantity Description Model Number Finish Mfr 6 EA HINGE 5BB1 4.5 X 4.5 NRP 630 IVE 2 EA SURFACE BOLT SB453-12-TB 626 IVE 1 EA STOREROOM LOCK ML2057 NSA - CONST KEYED (KNURLED @

MECH & ELEC) 626 C-R

1 EA SURFACE CLOSER 4041 SCUSH X TB - MOUNT TO SUIT CONDITIONS

689 LCN

1 EA OVERHEAD STOP 90S SERIES - SIZE AS REQ 630 GLY 1 SET SEALS 164V (HEAD & JAMBS) AL NGP 1 EA OH RAIN DRIP 16A DOOR WIDTH + 4" AL NGP 2 EA DOOR SWEEP 97VA AL NGP 1 EA THRESHOLD 324/425 AL NGP 1 ASTRAGAL/MEETING STILE BY DOOR

MANUFACTURER

MOUNT CLOSER ON ACTIVE LEAF. MOUNT OVERHEAD STOP ON INACTIVE LEAF.

Door Hardware 087100-11 CTC08131 Nursing and Classroom Building

Hardware Group No. 205 For use on door(s): B253A

Provide each SGL door(s) with the following:

Quantity Description Model Number Finish Mfr 1 EA CONTINUOUS HINGE 112HD HEIGHT AS REQ 628 IVE 1 EA STOREROOM LOCK ML2057 NSA - CONST KEYED 626 C-R 1 EA SURFACE CLOSER 4041 SCUSH X TB - MOUNT TO SUIT

CONDITIONS 689 LCN

1 EA DOOR BOTTOM 422N AL NGP 1 SET SEALS 164V (HEAD & JAMBS) AL NGP 1 EA OH RAIN DRIP 16A DOOR WIDTH + 4" AL NGP 1 EA DOOR SWEEP 97VA AL NGP 1 EA THRESHOLD 324/425 - REVIEW SILL DETAIL AL NGP

Hardware Group No. 206 – 303 – [NOT USED] Hardware Group No. 304 – 402 – [NOT USED] Hardware Group No. 403 For use on door(s): A221 A231 B106F B206 C118 C142 Provide each SGL door(s) with the following:

Quantity Description Model Number Finish Mfr 3 EA HINGE 5BB1 4.5 X 4.5 (HW @ 3'6" & LGR) 652 IVE 1 EA PASSAGE SET ML2010 NSA 626 C-R 1 EA STOP WS407CCV 626 IVE 1 SET SEALS 5050B BRN NGP

Hardware Group No. 404 – 500 – [NOT USED] Hardware Group No. 501 For use on door(s): A103 A104 A109 A114C A118 A232 A238 B106 B247 B248 C102 C104 C106 C108A C108B C114 C115 C116 C126 C133 C136 C139A C139B C139C C141A C141B C144 C146A C146B Provide each SGL door(s) with the following:

Quantity Description Model Number Finish Mfr 3 EA HINGE 5BB1 4.5 X 4.5 (HW @ 3'6" & LGR) 652 IVE 1 EA CLASSROOM LOCK ML2055 NSA - CONST KEYED 626 C-R 1 EA SURFACE CLOSER 4041 OR P4041 X TB - MOUNT TO SUIT

CONDITIONS 689 LCN

1 EA KICK PLATE 8400 12" X 1-1/2" LDW X B3E 630 IVE 1 EA STOP WS407CCV 626 IVE 1 SET SEALS 5050B BRN NGP

Door Hardware 087100-12 CTC08131 Nursing and Classroom Building

Hardware Group No. 501SS For use on door(s): A105 A105A Provide each SGL door(s) with the following:

Quantity Description Model Number Finish Mfr 3 EA HINGE 5BB1 4.5 X 4.5 (HW @ 3'6" & LGR) 652 IVE 1 EA CLASSROOM LOCK ML2055 NSA - CONST KEYED 626 C-R 1 EA SURFACE CLOSER 4041 OR P4041 X TB - MOUNT TO SUIT

CONDITIONS 689 LCN

1 EA KICK PLATE 8400 12" X 1-1/2" LDW X B3E 630 IVE 1 EA STOP WS407CCV 626 IVE 1 SET SEALS 700SA (MOUNT BEFORE OTHER HARDWARE) AL NGP 1 EA DOOR BOTTOM 422N AL NGP 1 EA THRESHOLD 324/425 AL NGP

Hardware Group No. 502 For use on door(s): B233 Provide each PR door(s) with the following:

Quantity Description Model Number Finish Mfr 6 EA HINGE 5BB1 4.5 X 4.5 (HW @ 3'6" & LGR) 652 IVE 2 EA SURFACE BOLT SB453-12-TB 626 IVE 1 EA CLASSROOM LOCK ML2055 NSA - CONST KEYED 626 C-R 1 SET ASTRAGAL 9605A AL NGP 2 EA KICK PLATE 8400 12" X 1" LDW X B3E 630 IVE 2 EA STOP WS407CCV 626 IVE 1 SET SEALS 5050B BRN NGP

Hardware Group No. 503 For use on door(s): B237 C110 C120 Provide each SGL door(s) with the following:

Quantity Description Model Number Finish Mfr 3 EA HINGE 5BB1 4.5 X 4.5 (HW @ 3'6" & LGR) 652 IVE 1 EA CLASSROOM LOCK ML2055 NSA - CONST KEYED 626 C-R 1 EA STOP WS407CCV 626 IVE 1 SET SEALS 5050B BRN NGP

Hardware Group No. 504 – 699 – [NOT USED]

Door Hardware 087100-13 CTC08131 Nursing and Classroom Building

Hardware Group No. 700 For use on door(s): A107A A111 B100B Provide each PR door(s) with the following:

Quantity Description Model Number Finish Mfr 2 EA CONTINUOUS HINGE 112HD HEIGHT AS REQ 628 IVE 1 EA MULLION KR4954 LENGTH AS REQUIRED 689 VON 2 EA PANIC HARDWARE 99L 996L X06 LEVER LENGTH AS REQUIRED 626 VON 3 EA CYLINDER IC CYLINDER W/CONST CORE - TYPE AS REQ 626 C-R 3 EA IC CORE ONLY, KEYED PERMENANT IC CORE - KEYED AS REQ 626 C-R 2 EA SURFACE CLOSER 4041 OR P4041 X TB - MOUNT TO SUIT

CONDITIONS 689 LCN

2 EA KICK PLATE 8400 12" X 1-1/2" LDW X B3E 630 IVE 2 EA STOP WS407CCV 626 IVE 1 EA MULLION SEAL 5100B BRN NGP 1 SET SEALS 5050B BRN NGP

Hardware Group No. 700A For use on door(s): B201A B201B Provide each PR door(s) with the following:

Quantity Description Model Number Finish Mfr 2 EA CONTINUOUS HINGE 112HD HEIGHT AS REQ 628 IVE 1 EA MULLION KR4954 LENGTH AS REQUIRED 689 VON 2 EA PANIC HARDWARE 99L 996L X06 LEVER LENGTH AS REQUIRED 626 VON 3 EA CYLINDER IC CYLINDER W/CONST CORE - TYPE AS REQ 626 C-R 3 EA IC CORE ONLY, KEYED PERMANENT IC CORE - KEYED AS REQ 626 C-R 2 EA SURFACE CLOSER 4041 OR P4041 X TB - MOUNT TO SUIT

CONDITIONS 689 LCN

2 EA KICK PLATE 8400 12" X 1-1/2" LDW X B3E 630 IVE 2 EA STOP WS407CCV 626 IVE 1 ASTRAGAL/MEETING STILE BY DOOR

MANUFACTURER

Hardware Group No. 700RSS For use on door(s): B116 B251 Provide each PR door(s) with the following:

Quantity Description Model Number Finish Mfr 2 EA CONTINUOUS HINGE 112HD HEIGHT AS REQ 628 IVE 1 EA MULLION KR9954 LENGTH AS REQUIRED 689 VON 2 EA FIRE EXIT HARDWARE 99L-F 996LX06 LEVER LENGTH AS REQ-

STRIKE AS REQ 626 VON

3 EA CYLINDER IC CYLINDER W/CONST CORE - TYPE AS REQ 626 C-R 3 EA IC CORE ONLY, KEYED PERMANENT IC CORE - KEYED AS REQ 626 C-R 1 SET ASTRAGAL 9605A AL NGP 2 EA SURFACE CLOSER 4041 OR P4041 X TB - MOUNT TO SUIT

CONDITIONS 689 LCN

2 EA KICK PLATE 8400 12" X 1-1/2" LDW X B3E 630 IVE 2 EA STOP WS407CCV 626 IVE 1 EA MULLION SEAL 5100B BRN NGP 1 SET SEALS 700SA (MOUNT BEFORE OTHER HARDWARE) AL NGP

Door Hardware 087100-14 CTC08131 Nursing and Classroom Building

Quantity Description Model Number Finish Mfr 2 EA DOOR BOTTOM 422N AL NGP 1 EA THRESHOLD 324/425 - REVIEW SILL DETAIL AL NGP

Hardware Group No. 701 For use on door(s): A200 A259 Provide each SGL door(s) with the following:

Quantity Description Model Number Finish Mfr 1 EA CONTINUOUS HINGE 112HD HEIGHT AS REQ 628 IVE 1 EA PANIC HARDWARE 99L 996L X06 LEVER LENGTH AS REQUIRED 626 VON 1 EA CYLINDER IC CYLINDER W/CONST CORE - TYPE AS REQ 626 C-R 1 EA IC CORE ONLY, KEYED PERMANENT IC CORE - KEYED AS REQ 626 C-R 1 EA SURFACE CLOSER 4041 OR P4041 X TB - MOUNT TO SUIT

CONDITIONS 689 LCN

1 EA KICK PLATE 8400 12" X 1-1/2" LDW X B3E 630 IVE 1 EA STOP WS407CCV 626 IVE 1 SET SEALS 5050B BRN NGP

Hardware Group No. 701R For use on door(s): A119A A240 B119 B235 Provide each SGL door(s) with the following:

Quantity Description Model Number Finish Mfr 1 EA CONTINUOUS HINGE 112HD HEIGHT AS REQ 628 IVE 1 EA FIRE EXIT HARDWARE 99L-F 996LX06 LEVER LENGTH AS REQ-

STRIKE AS REQ 626 VON

1 EA CYLINDER IC CYLINDER W/CONST CORE - TYPE AS REQ 626 C-R 1 EA IC CORE ONLY, KEYED PERMANENT IC CORE - KEYED AS REQ 626 C-R 1 EA SURFACE CLOSER 4041 OR P4041 X TB - MOUNT TO SUIT

CONDITIONS 689 LCN

1 EA KICK PLATE 8400 12" X 1-1/2" LDW X B3E 630 IVE 1 EA STOP WS407CCV 626 IVE 1 SET SEALS 5050B BRN NGP

Hardware Group No. 702 – 703 – [NOT USED] Hardware Group No. 704A For use on door(s): A124 A126 A132 B118 B121B B125A Provide each PR door(s) with the following:

Quantity Description Model Number Finish Mfr 2 EA CONTINUOUS HINGE 112HD HEIGHT AS REQ 628 IVE 1 EA MULLION KR4954 LENGTH AS REQUIRED 689 VON 1 EA PANIC HARDWARE 99EO - LENGTH AS REQUIRED 626 VON 1 EA PANIC HARDWARE 99NL-OP - LENGTH AS REQUIRED 626 VON 2 EA CYLINDER IC CYLINDER W/CONST CORE - TYPE AS REQ 626 C-R 2 EA IC CORE ONLY, KEYED PERMANENT IC CORE - KEYED AS REQ 626 C-R 2 EA OFFSET DOOR PULL 8190-0 630 IVE 2 EA SURFACE CLOSER 4041 OR P4041 X TB - MOUNT TO SUIT

CONDITIONS 689 LCN

2 EA OVERHEAD STOP 100S SERIES - SIZE AS REQ 630 GLY

Door Hardware 087100-15 CTC08131 Nursing and Classroom Building

Quantity Description Model Number Finish Mfr 1 EA OH RAIN DRIP 16A DOOR WIDTH + 4" AL NGP 2 EA DOOR SWEEP 97VA AL NGP 1 EA THRESHOLD 324/425 - REVIEW SILL DETAIL AL NGP 1 ASTRAGAL/MEETING STILE BY DOOR

MANUFACTURER

1 PERIMETER SEAL BY DOOR MANUFACTURER Hardware Group No. 704AEO For use on door(s): B121A B125B Provide each PR door(s) with the following:

Quantity Description Model Number Finish Mfr 2 EA CONTINUOUS HINGE 112HD HEIGHT AS REQ 628 IVE 1 EA MULLION KR4954 LENGTH AS REQUIRED 689 VON 2 EA PANIC HARDWARE 99EO - LENGTH AS REQUIRED 626 VON 1 EA CYLINDER IC CYLINDER W/CONST CORE - TYPE AS REQ 626 C-R 1 EA IC CORE ONLY, KEYED PERMANENT IC CORE - KEYED AS REQ 626 C-R 2 EA OFFSET DOOR PULL 8190-0 630 IVE 2 EA SURFACE CLOSER 4041 OR P4041 X TB - MOUNT TO SUIT

CONDITIONS 689 LCN

2 EA OVERHEAD STOP 100S SERIES - SIZE AS REQ 630 GLY 1 EA OH RAIN DRIP 16A DOOR WIDTH + 4" AL NGP 2 EA DOOR SWEEP 97VA AL NGP 1 EA THRESHOLD 324/425 - REVIEW SILL DETAIL AL NGP 1 ASTRAGAL/MEETING STILE BY DOOR

MANUFACTURER

1 PERIMETER SEAL BY DOOR MANUFACTURER Hardware Group No. 705 For use on door(s): A119D Provide each SGL door(s) with the following:

Quantity Description Model Number Finish Mfr 1 EA CONTINUOUS HINGE 112HD HEIGHT AS REQ 628 IVE 1 EA PANIC HARDWARE 99NL X 990NL LENGTH AS REQUIRED 626 VON 1 EA CYLINDER IC CYLINDER W/CONST CORE - TYPE AS REQ 626 C-R 1 EA IC CORE ONLY, KEYED PERMANENT IC CORE - KEYED AS REQ 626 C-R 1 EA SURFACE CLOSER 4041 OR P4041 X TB - MOUNT TO SUIT

CONDITIONS 689 LCN

1 EA SECURITY FLOOR STOP FS18S BLK IVE 1 SET SEALS 164V (HEAD & JAMBS) AL NGP 1 EA OH RAIN DRIP 16A DOOR WIDTH + 4" AL NGP 1 EA DOOR SWEEP 97VA AL NGP 1 EA THRESHOLD 324/425 - REVIEW SILL DETAIL AL NGP

Door Hardware 087100-16 CTC08131 Nursing and Classroom Building

Hardware Group No. 705A For use on door(s): A101 C100 C125 Provide each SGL door(s) with the following:

Quantity Description Model Number Finish Mfr 1 EA CONTINUOUS HINGE 112HD HEIGHT AS REQ 628 IVE 1 EA PANIC HARDWARE 99NL-OP - LENGTH AS REQUIRED 626 VON 1 EA CYLINDER IC CYLINDER W/CONST CORE - TYPE AS REQ 626 C-R 1 EA IC CORE ONLY, KEYED PERMANENT IC CORE - KEYED AS REQ 626 C-R 1 EA OFFSET DOOR PULL 8190-0 630 IVE 1 EA SURFACE CLOSER 4041 OR P4041 X TB - MOUNT TO SUIT

CONDITIONS 689 LCN

1 EA SECURITY FLOOR STOP FS18S BLK IVE 1 EA OH RAIN DRIP 16A DOOR WIDTH + 4" AL NGP 1 EA DOOR SWEEP 97VA AL NGP 1 EA THRESHOLD 324/425 - REVIEW SILL DETAIL AL NGP 1 PERIMETER SEAL BY DOOR MANUFACTURER

Hardware Group No. 705R For use on door(s): A142 B120 Provide each SGL door(s) with the following:

Quantity Description Model Number Finish Mfr 1 EA CONTINUOUS HINGE 112HD HEIGHT AS REQ 628 IVE 1 EA FIRE EXIT HARDWARE 99NL-F LENGTH AS REQUIRED 626 VON 1 EA CYLINDER IC CYLINDER W/CONST CORE - TYPE AS REQ 626 C-R 1 EA IC CORE ONLY, KEYED PERMANENT IC CORE - KEYED AS REQ 626 C-R 1 EA SURFACE CLOSER 4041 OR P4041 X TB - MOUNT TO SUIT

CONDITIONS 689 LCN

1 EA SECURITY FLOOR STOP FS18S BLK IVE 1 SET SEALS 164V (HEAD & JAMBS) AL NGP 1 EA OH RAIN DRIP 16A DOOR WIDTH + 4" AL NGP 1 EA DOOR SWEEP 97VA AL NGP 1 EA THRESHOLD 324/425 AL NGP

Hardware Group No. 760 – 799 – [NOT USED] Hardware Group No. 800A For use on door(s): A125A A125B B100A B122A B122B B122C B122D Provide each PR door(s) with the following:

Quantity Description Model Number Finish Mfr 2 EA CONTINUOUS HINGE 112HD HEIGHT AS REQ 628 IVE 2 EA DUMMY TOUCH BAR 330 - LENGTH AS REQUIRED 626 VON 2 EA OFFSET DOOR PULL 8190-0 630 IVE 2 EA SURFACE CLOSER 4041 OR P4041 X TB - MOUNT TO SUIT

CONDITIONS 689 LCN

2 EA STOP WS407CCV 626 IVE 1 ASTRAGAL/MEETING STILE BY DOOR

MANUFACTURER

Door Hardware 087100-17 CTC08131 Nursing and Classroom Building

Hardware Group No. 801A For use on door(s): A107B C101A C101B Provide each SGL door(s) with the following:

Quantity Description Model Number Finish Mfr 1 EA CONTINUOUS HINGE 112HD HEIGHT AS REQ 628 IVE 1 EA DUMMY TOUCH BAR 330 - LENGTH AS REQUIRED 626 VON 1 EA OFFSET DOOR PULL 8190-0 630 IVE 1 EA SURFACE CLOSER 4041 OR P4041 X TB - MOUNT TO SUIT

CONDITIONS 689 LCN

1 EA STOP WS407CCV 626 IVE Hardware Group No. 801ADL For use on door(s): B204 Provide each SGL door(s) with the following:

Quantity Description Model Number Finish Mfr 1 EA CONTINUOUS HINGE 112HD HEIGHT AS REQ 628 IVE 1 EA DEADLOCK MS1850S (PROVIDE BACKSET AS REQUIRED) 628 ADA 1 EA CYLINDER CYLINDER W/CONST CORE - TYPE AS REQ 626 C-R 1 EA PULL/PUSHBAR 9190-0-NO 630 IVE 1 EA SURFACE CLOSER 4041 OR P4041 X TB - MOUNT TO SUIT

CONDITIONS 689 LCN

1 EA KICK PLATE 8400 12" X 1-1/2" LDW X B3E 630 IVE 1 EA STOP WS407CCV 626 IVE

Hardware Group No. 801DL For use on door(s): A134 A135 A235 A236 B113 B114 B252 B254 C111 C113 Provide each SGL door(s) with the following:

Quantity Description Model Number Finish Mfr 3 EA HINGE 5BB1 4.5 X 4.5 (HW @ 3'6" & LGR) 652 IVE 1 EA DEADBOLT DL3117 626 C-R 1 EA PUSH PLATE 8200 4" X 16" 630 IVE 1 EA PULL PLATE 8302-0 4" X 16" 630 IVE 1 EA SURFACE CLOSER P4041 X TB 689 LCN 1 EA KICK PLATE 8400 12" X 1-1/2" LDW X B3E 630 IVE 1 EA STOP WS407CCV 626 IVE 1 SET SEALS 5050B BRN NGP

MOUNT DEADLOCK AT 48" AND PUSH/PULL BELOW DEADLOCK. Hardware Group No. 802 – C700 – [NOT USED] Hardware Group No. C701 For use on door(s): A127A A127B A130A A130B A131A A131B A136A A136B A139A A139B B101A B101B B102A B102B B103A B103B B104A B104B B105A B105B B107A B107B B109A B109B B111A B111B B112A B112B

Door Hardware 087100-18 CTC08131 Nursing and Classroom Building

Provide each SGL door(s) with the following: Quantity Description Model Number Finish Mfr

1 EA CONTINUOUS HINGE 112HD HEIGHT AS REQ 628 IVE 1 EA PANIC HARDWARE 99EO - LENGTH AS REQUIRED 626 VON 1 EA CYLINDER IC CYLINDER W/CONST CORE - TYPE AS REQ 626 C-R 1 EA IC CORE ONLY, KEYED PERMANENT IC CORE - KEYED AS REQ 626 C-R 1 EA ACCESS CONTROL LOCK CM993-PXK-06-ATK 626 SCE 1 EA SURFACE CLOSER 4041 OR P4041 X TB - MOUNT TO SUIT

CONDITIONS 689 LCN

1 EA KICK PLATE 8400 12" X 1-1/2" LDW X B3E 630 IVE 1 EA STOP WS407CCV 626 IVE 1 SET SEALS 5050B BRN NGP

INGRESS BY READER OR KEY OVERRIDE, EGRESS BY PUSH PAD. PROVIDE NECESSARY CARDS AS

REQUIRED. Hardware Group No. C702 – C703 – [NOT USED] Hardware Group No. C704 For use on door(s): A121B Provide each PR door(s) with the following:

Quantity Description Model Number Finish Mfr 2 EA CONTINUOUS HINGE 112HD HEIGHT AS REQ 628 IVE 1 EA MULLION KR4954 LENGTH AS REQUIRED 689 VON 2 EA PANIC HARDWARE 99EO - LENGTH AS REQUIRED 626 VON 3 EA CYLINDER IC CYLINDER W/CONST CORE - TYPE AS REQ 626 C-R 3 EA IC CORE ONLY, KEYED PERMANENT IC CORE - KEYED AS REQ 626 C-R 2 EA ACCESS CONTROL LOCK CM993-PXK-06-ATK 626 SCE 1 SET ASTRAGAL 9605A AL NGP 2 EA SURFACE CLOSER 4041 OR P4041 X TB - MOUNT TO SUIT

CONDITIONS 689 LCN

2 EA SECURITY FLOOR STOP FS18S BLK IVE 1 SET SEALS 164V (HEAD & JAMBS) AL NGP 2 EA DOOR SWEEP 97VA AL NGP 1 EA THRESHOLD 324/425 AL NGP

INGRESS BY READER OR KEY OVERRIDE, EGRESS BY PUSH PAD. PROVIDE NECESSARY CARDS AS

REQUIRED. Hardware Group No. C705 – C900 – [NOT USED] Hardware Group No. C901 For use on door(s): A108 A110 A114A A114B A116A A116B A121A A122 A123 A201A A201B A260 A261 B202 B203 Provide each SGL door(s) with the following:

Quantity Description Model Number Finish Mfr 3 EA HINGE 5BB1 4.5 X 4.5 (HW @ 3'6" & LGR) 652 IVE 1 EA CYLINDER CYLINDER W/CONST CORE - TYPE AS REQ 626 C-R 1 EA ACCESS CONTROL LOCK CM5594-PXK-06-ATK 626 SCE

Door Hardware 087100-19 CTC08131 Nursing and Classroom Building

Quantity Description Model Number Finish Mfr 1 EA SURFACE CLOSER 4041 OR P4041 X TB - MOUNT TO SUIT

CONDITIONS 689 LCN

1 EA KICK PLATE 8400 12" X 1-1/2" LDW X B3E 630 IVE 1 EA STOP WS407CCV 626 IVE 1 SET SEALS 5050B BRN NGP

INGRESS BY READER OR KEY OVERRIDE, EGRESS BY PUSH PAD. PROVIDE NECESSARY CARDS AS

REQUIRED.

END OF SECTION