INDEX
Specifications are subject to change without notice.
RECTIFIERS AND CONVERTERS 46
Flatpack 700 and 1500 . . . . . . . . . . . . . 48Slimpack . . . . . . . . . . . . . . . . . . . . . . . 50SMPS 200 . . . . . . . . . . . . . . . . . . . . . . 51SMPS 1000 . . . . . . . . . . . . . . . . . . . . . . 52TwinPack Plus® . . . . . . . . . . . . . . . . . . 53SMPS 4000 . . . . . . . . . . . . . . . . . . . . . . 54RM 14400 . . . . . . . . . . . . . . . . . . . . . . 55
Flatpack DC/DC converter . . . . . . . . . . . 56
SYSTEM MONITORS . . . . . . . . . . 58
Flatpack MCU . . . . . . . . . . . . . . . . . . . . 60TWPP/MCU panel . . . . . . . . . . . . . . . . . . 61AL 175NT . . . . . . . . . . . . . . . . . . . . . . . 62AEON Gold . . . . . . . . . . . . . . . . . . . . . . 63WinPower . . . . . . . . . . . . . . . . . . . . . . . 64SNMP Adapter . . . . . . . . . . . . . . . . . . . . 65WebPower . . . . . . . . . . . . . . . . . . . . . . 66
OTHER PRODUCTSAND SERVICES . . . . . . . . . . . . . . . 67
Outdoor cabinet solutions . . . . . . . . . . . 68Remote powering of broadband/ DSL . . . 69Extensive service offer . . . . . . . . . . . . . . 70
ABBREVIATIONS . . . . . . . . . . . . . 71
DC POWER SYSTEMS . . . . . . . . . 8
CE systems . . . . . . . . . . . . . . . . . . . . . 10Flatpack MPSU 3000 . . . . . . . . . . . . . . . 11Flatpack MPSU 6000 . . . . . . . . . . . . . . . 12Flatpack MPSU 9000 . . . . . . . . . . . . . . . 13Flatpack MPSU 12 kW . . . . . . . . . . . . . . 14Flatpack PRSB 9000 . . . . . . . . . . . . . . . 15Flatpack PRSB 15 kW . . . . . . . . . . . . . . 16
Flatpack PRSB 21 kW . . . . . . . . . . . . . . 17Flatpack PRSB 30 kW . . . . . . . . . . . . . . 18Flatpack Wallbox 3000 . . . . . . . . . . . . . . 19Flatpack Power Tower . . . . . . . . . . . . . . 20MPSU 200 . . . . . . . . . . . . . . . . . . . . . . 21MPSU 4000 . . . . . . . . . . . . . . . . . . . . . . 22MPSU 5000 . . . . . . . . . . . . . . . . . . . . . . 23MPSU 6000 . . . . . . . . . . . . . . . . . . . . . . 24PRS 700 . . . . . . . . . . . . . . . . . . . . . . . . 25AEON 4000 . . . . . . . . . . . . . . . . . . . . . . 26SVS system . . . . . . . . . . . . . . . . . . . . . 27
DC Distribution for CE systems . . . . . 29PDU 19" MCB distribution 24 way . . . . . . 29DCD 22 Way and 40 Way with LVBD . . . . 30DCD 4000 system . . . . . . . . . . . . . . . . . 31PDU . . . . . . . . . . . . . . . . . . . . . . . . . . . 32BDU . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
UL systems . . . . . . . . . . . . . . . . . . . . . 34DCD 125AP Flatpack system . . . . . . . . . . 35DCD 3FM-200A Flatpack system . . . . . . . 36400A/600A Flatpack system . . . . . . . . . . 37
Flatpack Cabinetized system . . . . . . . . . . 38TwinPack Plus® Power system . . . . . . . . 39AEON 4000 AM Single Cabinet system . . . 40High Current AEON systems . . . . . . . . . . 41
DC Distribution for UL systems . . . . . 424U Plug-in PDU . . . . . . . . . . . . . . . . . . . 42144 Position Plug-in PDU . . . . . . . . . . . . 43GMT Fuse distribution . . . . . . . . . . . . . . 44
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 3/72
3
Welcome to Eltek!
Dear valued customer,
As a global company with 100% focus on Telecom Power, Eltek is in a
unique position in today’s market. All efforts throughout our organization
are directed towards Telecom Power. This enables us to meet global as
well as local requirements through market knowledge and dedicated
personnel.
Over the last 2 to 3 years Eltek has chosen the opposite path of otheractors in the Telecom Power Market. While others have reorganized
and reduced their staff, Eltek has significantly increased the number of
R&D engineers. The result of our efforts can be seen in the compre-
hensive and cost effective product range presented in this catalog.
As you will see from the catalog, Eltek have products to match any
requirement. Small sites are covered by systems based on the
SMPS 200 or Flatpack 700 rectifier modules, the medium range by the
successful Flatpack 1500 module and larger sites by AEON rectifier
systems. The Flatpack DC/DC converters further enable us to provide
systems providing both 24 and 48 VDC from one battery bank againgiving a very cost effective and compact solution.
Remote management of DC Power systems over the web is an increasingly
discussed topic. We have responded to this requirement and are proud
to present WebPower. With WebPower we have integrated SNMP function-
ality with very easy system access over the web as well as mail alert.
Eltek can provide turn key solutions for indoor as well as outdoor
applications.
We hope that you will find products to match your requirement in thiscatalog. We are only a phone-call or e-mail away and we are all more
than happy to respond to any enquiry you may have.
Yours sincerely
For Eltek Energy AS
Morten Schoyen
Director Telecom Support and Product Management
The products herein
reflect our vision
"To become the global
center of excellence
within Telecom Power".
MORTEN SCHØYEN
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 4/72
FP MPSU 6000
6000 W
24, 48, 60* VDC
4 Flatpack 1500
230/400 + N VAC
CE
-40oC to +60oC
Forced convectionMCU with Display/
RS-232/ Ethernet/
Modem/Web/SNMP
Temp comp/ Volt/
Current/ Capacity
Circuit breakers
UMTS & GSM Base
Stations
Point of Presence (POPs)
Digital Loop Carrier (DLC)
Fiber Repeater
E911 (Public Safety)
Microwave
Digital Subscriber Line
FP MPSU 3000
3000 W
24, 48, 60* VDC
2 Flatpack 1500 or
Flatpack 700
230/400 + N VAC
CE
-40oC to +60oC
Forced convectionMCU with Display/
RS-232/ Ethernet/
Modem/Web/SNMP
Temp comp/ Volt/
Current/ Capacity
Circuit breakers
Small UMTS & GSM Base
Stations
Point of Presence (POPs)
Digital Loop Carrier (DLC)
Fiber Repeater
E911 (Public Safety)
Microwave
Digital Subscriber Line
DC Power SystemsFeature Matrix for CE systems
SMALL AND MEDIUM
MPSU 200
1600 W
48 VDC
8 SMPS 200
230 VAC
CE
-10oC to +55oC
ConvectionAL 175NT with Display/
RS-232/ Ethernet/
Modem/Web/SNMP
Temp comp/ Volt/
Current/ Capacity
Circuit breakers
Point of Presence (POPs)
Digital Loop Carrier (DLC)
Fiber Repeater
E911 (Public Safety)
Microwave
Digital Subscriber Line
(DSL)
Micro Cell Base Station
Features
Max. Power level
Voltages
Max. Number of rectifiers
AC input
Approvals
Temperature rating
CoolingSystem monitoring
Battery monitor
DC distribution
Typical applications
FP MPSU 9000
9000 W
24, 48, 60* VDC
6 Flatpack 1500
230/400 + N VAC
CE
-40oC to +60oC
Forced convectionMCU with Display/
RS-232/ Ethernet/
Modem/Web/SNMP
Temp comp/ Volt/
Current/ Capacity
Circuit breakers
UMTS & GSM Base
Stations
Digital Loop Carrier (D
E911 (Public Safety)
Microwave
Digital Subscriber Li
Co-location
Telephone Switches
* to be released in 2004 (other 60 VDC products available)
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 5/72
FP PRSB 15 kW
15 kW
24, 48, 60* VDC
10 Flatpack 1500
230/400 + N VAC
CE
-40oC to +60oC
Forced convectionMCU with Display/
RS-232/ Ethernet/
Modem/Web/SNMP
Temp comp/ Volt/
Current/ Capacity
Circuit breakers/ Fuses
UMTS & GSM Base
Stations
Digital Loop Carrier (DLC)
E911 (Public Safety)
Telephone Switches
Data Center
Internet Hubs
Optical Switches
Co-location
GSM Backbone Stations
MPSU 12 kW
kW
, 48, 60* VDC
Flatpack 1500
0/400 + N VAC
0oC to +60oC
rced convectionCU with Display/ RS-
2/ Ethernet/
odem/Web/SNMP
mp comp/ Volt/
rrent/ Capacity
rcuit breakers
MTS & GSM Base
ations
gital Loop Carrier (DLC)
11 (Public Safety)
crowave
gital Subscriber Line
-location
ephone Switches
ternet Hubs
LARGE
FP PRSB 21 kW
21 kW
24, 48, 60* VDC
14 Flatpack 1500
230/400 + N VAC
CE
-40oC to +60oC
Forced convectionMCU with Display/
RS-232/ Ethernet/
Modem/Web/SNMP
Temp comp/ Volt/
Current/ Capacity
Circuit breakers/ Fuses
UMTS & GSM Base
Stations
Digital Loop Carrier (DLC)
E911 (Public Safety)
Telephone Switches
Data Center
Internet Hubs
Optical Switches
Co-location
GSM Backbone Stations
FP PRSB 30 kW
30 kW
24, 48, 60* VDC
20 Flatpack 1500
230/400 + N VAC
CE
-40oC to +60oC
Forced convectionMCU with Display/
RS-232/ Ethernet/
Modem/Web/SNMP
Temp comp/ Volt/
Current/ Capacity
Circuit breakers/ Fuses
UMTS & GSM Base
Stations
Digital Loop Carrier (DLC)
E911 (Public Safety)
Telephone Switches
Data Center
Internet Hubs
Optical Switches
Co-location
GSM Backbone Stations
AEON 4000
24 VDC/ 320 kW,
48, 60 VDC/ 384 kW
24, 48, 60 VDC
24 SMPS 4000
(single cabinet)
230/400/480 VAC
CE
-10oC to +55oC
Forced convectionAEON Gold with Display/
RS-232/ Ethernet/
Modem
Temp comp/ Volt/
Current/ Capacity
Circuit breakers/ Fuses
Telephone Switches
Data Center
Internet Hubs
Optical Switches
Co-location
Fixed Net Backbone Sites
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 6/72
6
400A Flatpack system
18 kW
48 VDC
12 Flatpack 1500
120/208/240 Single Phase VA
UL, CE, NEBS level 3
-40o
C to +70o
CForced convection
MCU with Display/RS-232/
Ethernet/Modem/Web/SNMP
Temp comp/Volt/Current/
Capacity
Up to 24 Circuit breakers or
Fuses
UMTS and GSM Base Station
Point of Presence (POPs)
Digital Loop Carrier (DLC)
Fiber Repeater
E911 (Public Safety)
Small Microwave
Digital Subscriber Line
DCD 3FM-200A Flatpack system
9000 W
48 VDC
6 Flatpack 1500
120/208/240 Single Phase VAC
UL, CE, NEBS level 3
-40o
C to +70o
CForced convection
MCU with Display/RS-232/
Ethernet/Modem/Web/SNMP
Temp comp/Volt/Current/
Capacity
Up to 14 Circuit breakers or
Fuses
UMTS and GSM Base Stations
Point of Presence (POPs)
Digital Loop Carrier (DLC)
Fiber Repeater
E911 (Public Safety)
Small Microwave
Digital Subscriber Line
DC Power SystemsFeature Matrix for UL systems
SMALL AND MEDIUM
DCD 125AP Flatpack system
6000 W
48 VDC
4 Flatpack 1500
120/208/240 Single Phase VAC
UL, CE, NEBS level 3
-40o
C to +70o
CForced convection
MCU with Display/ RS-232/
Ethernet/Modem/Web/SNMP
Temp comp/Volt/Current/
Capacity
Circuit breaker and Fuses
UMTS and GSM Base Stations
Point of Presence (POPs)
Digital Loop Carrier (DLC)
Fiber Repeater
E911 (Public Safety)
Small Microwave
Digital Subscriber Line
Features
Max. Power level
Voltages
Max. Number of rectifiers
AC input
Approvals
Temperature ratingCooling
System monitoring
Battery monitor
DC distribution
Typical applications
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 7/72
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 8/72
DC Power systems
8
This section outlines the standard DC Power systems offered by Eltek. Our systems cover the entire
range of application areas within the telecommunications industry. A typical DC Power system includes
rectifiers, control and monitoring modules, AC distribution for rectifier input, DC distribution, batteries,
and low voltage disconnect options. All of our systems use state of the art "hot plug-in" switchmode
rectifiers for easily upgradable system power capability. Multiple rectifiers operate in parallel to ensure
redundant operation. For the purpose of this catalog Eltek’s systems are classified according to safety
agency recognition into CE-marked and UL-recognized. Furthermore the systems are classified into two
power ranges: small and medium, and large systems.
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 9/72
9
DC POWER SYSTEMS
CE SYSTEMS ............................. 10SMALL AND MEDIUM SYSTEMS
WITH FORCED CONVECTION
Flatpack MPSU 3000 .................... 11Flatpack MPSU 6000 .................... 12Flatpack MPSU 9000 .................... 13Flatpack MPSU 12 kW .................. 14Flatpack PRSB 9000 .................... 15Flatpack PRSB 15 kW .................. 16Flatpack PRSB 21 kW .................. 17Flatpack PRSB 30 kW .................. 18Flatpack Wallbox 3000 ................. 19Flatpack Power Tower .................. 20
SMALL AND MEDIUM SYSTEMS
WITH NATURAL CONVECTION
MPSU 200 .................................. 21MPSU 4000 ................................ 22MPSU 5000 ................................ 23MPSU 6000 ................................ 24PRS 700 .................................... 25
LARGE SYSTEMS
AEON 4000 ................................ 26SVS system................................. 27
DC DISTRIBUTION FOR CE SYSTEMS
PDU 19" MCB ............................. 29DCD 22 Way and 40 Way with LVBD 30DCD 4000 system ....................... 31PDU .......................................... 32BDU .......................................... 33
UL SYSTEMS ............................. 34
SMALL AND MEDIUM SYSTEMSDCD 125AP Flatpack system ......... 35DCD 3FM-200A Flatpack system .... 36400A/600A Flatpack system ......... 37Flatpack Cabinetized system ......... 38TwinPack Plus® Power system ...... 39
LARGE SYSTEMS
AEON 4000 AM Single cabinet system 40High Current AEON system ........... 41
DC DISTRIBUTION FOR UL SYSTEMS
4U Plug-in PDU ........................... 42
144 Position Plug-in PDU ............. 43GMT Fuse distribution .................. 44
Small and medium systems are designed for both stand-alone and
integrated solutions. The systems provide both convection (MPSU 200,
MPSU 4000, MPSU 5000, MPSU 6000) and forced air-cooling (Flatpack
systems) regimes for all colocated equipment. Applications in either
indoor or outdoor cabinets are typically used to power equipment such as
POPs (Points of Presence), DLC (Digital Loop Carrier) cabinets, E911
(Public Safety), 3G Wireless base stations, Fiber Repeaters, GSM/TDMA/-
CDMA wireless network base stations, Small Microwave Networks and
Small Telephone Switches.
The Flatpack Power systems are Eltek’s latest development in the small
and medium power range and represents the ultimate choice for compact,
reliable, flexible and durable power systems at low cost. A typical
Flatpack Power system contains Flatpack 1500 rectifiers, Power Racks
(PRs), a Monitoring and Control Unit (MCU) and a DC distribution system
of appropriate size and configuration. Multiple PRs may be combined and
paralleled to form power systems ranging from 1500 W to 60 kW. The
building block philosophy enables Eltek to tailor highly advanced power
systems according to customer requirements iin short timescale and at
low cost. Flatpack systems can be delivered as rack mountable units, or
in cabinets of different sizes with optional space for internal batteries.
Large systems are designed for stand-alone solutions where high power
is required. These systems are typically used for Central Office Switches,
Internet Hubs, Web Hosting Sites, Optical Switches and Fixed Net Backbone
Switches. AEON 4000 operates from 230 single phase VAC or 400 three
phase VAC + N input. The High Current AEON 4000 also operates from a
208/480 VAC three phase input, for installations in the Americas.
All Eltek products and systems comply with international and local
standards. Our ambition is, however, to provide power solutions that offer
more than just technical compliance. Our aim is to build products andsystems that are easy to install and maintain, with user-friendly software
and monitoring systems, simple maintenance procedures, and an attractive
technical and visual design. We seek to build systems for the future that
comply with the strictest environmental requirements - anywhere in the
world. Our success also means success for our customers.
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 10/72
10
All Eltek core elements, including rectifiers, converters and system
monitors, are approved for worldwide applications including UL, CE
and NEBS recognition and approval.
This section of our catalog details different system solutions bearing
CE marking.
CE-marking is a European marking of conformity that indicates
that a product complies with the essential requirements of the
applicable European laws or Directives with respect to safety,
health, environment and consumer protection.
DC distribution options for CE-marked systems are also describedin this part of the catalogue.
CE-marked DC Power systemsand DC Distribution products
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 11/72
11
Flatpack MPSU 3000
KEY FEATURES
System
• Max. number of rectifiers: 2• Input voltage:
- 1 phase 230 VAC- 3 phase 230 VAC ( )- 3 phase 400 VAC+N ( Y )
• Frequency: 45 to 66Hz• Operating temperature: -40 to +60°C
(-40 to +140°F)• Storage temperature: -40 to +85°C
(-40 to +185°F)• Dimensions (wxdxh):
- 482 x 300 x 89mm (2U)/19 x 11.8 x 3.5"- 482 x 300 x 178mm (4U)/19 x 11.8 x 7"• Weight: approx. excl. rectifiers
- 2U/5kg (11lbs)- 4U/7kg (15.5lbs)
Rectifier
• Flatpack 700• Flatpack 1500
Monitoring Unit
• Flatpack MCU
DC Distribution
Flatpack MPSU 3000 2U, DC distribution in 1U• Option 1:
- 2 battery MCBs and 6 load MCBs- Programmable LVD:
Standard/1 LVBD (max. 125 Amps)Optional/1 LVLD (max. 125 Amps)
• Option 2*:- 3 load MCBs, 1 load fuse and 1 battery fuse- Programmable LVD:
Standard/1 LVBD (max. 125 Amps)Optional/1 LVLD (max. 125 Amps)
Flatpack MPSU 3000 4U, DC distribution in 3U• Up to 4 battery MCBs and up to 19 load MCBs• Programmable LVD:
- Standard/1 LVBD (max. 250 Amps)- Optional/1 LVLD (max. 250 Amps)
Applicable standards
• Safety: EN 60950, UL 60950• EMC:
- ETSI EN 300 386 V.1.3.1 (telecom. network)- EN 61000-6-3 (emission, light industry)- EN 61000-6-2 (immunity, industry)
• Environment:- ETSI EN 300 019-2- ETSI EN 300 132-2
Approvals
• CE-marked
* UL-recognition for MPSU 3000 2U, DC distribution in 1U, Option 2
Description
The Flatpack MPSU 3000 has been specifically designed to meet the
demand for higher density and more compact power solutions. The
Flatpack MPSU 3000 is a compact power system containing a Monitoring
and Control Unit (MCU), LVD, battery and load MCBs. It can house up to
two Flatpack 700 or 1500 rectifier modules. The system accepts large
variations in the input voltage and draws sinusoidal current with a soft
start power-up. The Flatpack MPSU 3000 will operate in ambient tempera-
tures up to +60°C (+140°F). At higher temperatures, each rectifier will
derate the output power for self-protection. Flatpack MPSU 3000 isavailable in 24, 48, and 60 VDC configurations.
Typical applications
• Small UMTS and GSM Base Stations
• Point of Presence (POPs)
• Digital Loop Carrier (DLC)
• Fiber Repeater
• E911 (Public Safety)
• Microwave
• Digital Subscriber Line
Flatpack MPSU 3000 with 1U distribution
Flatpack MPSU 3000 with 3U distribution
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 12/72
Flatpack MPSU 6000 with 3U distribution
12
Flatpack MPSU 6000 with 1U distribution
Flatpack MPSU 6000
KEY FEATURES
System
• Max. number of rectifiers: 4• Input voltage:
- 1 phase 230 VAC- 3 phase 230 VAC ( )- 3 phase 400 VAC+N ( Y )
• Frequency: 45 to 66Hz• Operating temperature: -40 to +60°C
(-40 to +140°F)• Storage temperature: -40 to +85°C
(-40 to +185°F)• Dimensions (wxdxh):
- 482 x 300 x 134mm (3U)/19 x 11.8 x 5.3"- 482 x 300 x 223mm (5U)/19 x 11.8 x 8.7"• Weight: approx. excl. rectifiers
- 3U/6kg (13.2lbs)- 5U/10kg (22lbs)
Rectifier
• Flatpack 700• Flatpack 1500
Monitoring Unit
• Flatpack MCU
DC Distribution
Flatpack MPSU 6000 3U, DC distribution in 1U• Option 1:
- 2 battery MCBs and 6 load MCBs- Programmable LVD:
Standard/1 LVBD (max. 125 Amps)Optional/1 LVLD (max. 125 Amps)
• Option 2*:- 3 load MCBs, 1 load fuse and 1 battery fuse- Programmable LVD:
Standard/1 LVBD (max. 125 Amps)Optional/1 LVLD (max. 125 Amps)
Flatpack MPSU 6000 5U, DC distribution in 3U• Up to 4 battery MCBs and up to 19 load MCBs• Programmable LVD:
Standard/1 LVBD (max. 250 Amps)Optional/1 LVLD (max. 250 Amps)
Applicable standards
• Safety: EN 60950, UL 60950• EMC:
- ETSI EN 300 386 V.1.3.1 (telecom. network)- EN 61000-6-3 (emission, light industry)- EN 61000-6-2 (immunity, industry)
• Environment:- ETSI EN 300 019-2- ETSI EN 300 132-2
Approvals
• CE-marked
* UL-recognition for MPSU 6000 3U, DC distribution in 1U,
Option 2
Description
The Flatpack MPSU 6000 has been specifically designed to meet the
demand for higher density and more compact power solutions. It is
suitable for applications needing an expandable, easily serviceable and
reliable power supply, fitting within a minimal space. The Flatpack MPSU
6000 is a compact power system containing a Monitoring and Control Unit
(MCU), LVD, battery and load MCBs. It can house up to four Flatpack 700 or
1500 rectifier modules. The system accepts large variations in the input
voltage and draws sinusoidal current with a soft start power-up. The
Flatpack MPSU 6000 will operate in ambient temperatures up to +60°C(+140°F). At higher temperatures, each rectifier will derate the output
power for self-protection. Flatpack MPSU 6000 is available in 24, 48 and
60 VDC configurations.
Typical applications
• UMTS and GSM Base Stations
• Point of Presence (POPs)
• Digital Loop Carrier (DLC)
• Fiber Repeater
• E911 (Public Safety)
• Microwave• Digital Subscriber Line
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 13/72
13
Flatpack MPSU 9000
Description
The Flatpack MPSU 9000 has been specifically designed to meet the
demand for higher density and more compact power solutions. It is
suitable for applications needing an expandable, easily serviceable and
reliable power supply, fitting within a minimal space. The Flatpack MPSU
9000 is a compact power system containing a Monitoring and Control Unit
(MCU), LVD, battery and load MCBs. It can house up to six Flatpack 700
or 1500 rectifier modules. The system accepts large variations in the input
voltage and draws sinusoidal current with a soft start power-up. The
Flatpack MPSU 9000 will operate in ambient temperatures up to +60°C(+140°F). At higher temperatures, each rectifier will derate the output
power for self-protection. Flatpack MPSU 9000 is available in 24, 48 and
60 VDC configurations.
Typical applications
• UMTS and GSM Base Stations
• Digital Loop Carrier (DLC)
• E911 (Public Safety)
• Microwave
• Digital Subscriber Line
• Telephone Switches• Co-location
KEY FEATURES
System
• Max. number of rectifiers: 6• Input voltage:
- 1 phase 230 VAC- 3 phase 230 VAC ( )- 3 phase 400 VAC+N ( Y )
• Frequency: 45 to 66Hz• Operating temperature: -40 to +60°C
(-40 to +140°F)• Storage temperature: -40 to +85°C
(-40 to +185°F)• Dimensions (wxdxh):
482 x 300 x 267mm (6U)/19 x 11.8 x 10.5"• Weight: approx. 15kg (33lbs) excl. rectifiers
Rectifier
• Flatpack 700• Flatpack 1500
Monitoring Unit
• Flatpack MCU
DC Distribution
• Up to 4 battery MCBs and 19 load MCBs• Programmable LVD:
- Standard/1 LVBD (max. 250 Amps)- Optional/1 LVLD (max. 250 Amps)
Applicable standards
• Safety: EN 60950, UL 60950
• EMC:- ETSI EN 300 386 V.1.3.1
(telecom. network)- EN 61000-6-3 (emission, light industry)- EN 61000-6-2 (immunity, industry)
• Environment:- ETSI EN 300 019-2- ETSI EN 300 132-2
Approvals
• CE-marked
Flatpack MPSU 9000
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 14/72
14
Flatpack MPSU 12 kW
Description
The Flatpack MPSU 12 kW has been specifically designed to meet the
demand for higher density and more compact power solutions. It is
suitable for applications needing an expandable, easily serviceable and
reliable power supply, fitting within a minimal space. The Flatpack MPSU
12 kW is a compact power system containing a Monitoring and Control
Unit (MCU), LVD, battery and load MCBs. It can house up to eight
Flatpack 1500 rectifier modules. The system accepts large variations in
the input voltage and draws sinusoidal current with a soft start power-up.
The Flatpack MPSU 12 kW will operate in ambient temperatures up to+60°C (+140°F). At higher temperatures, each rectifier will derate the
output power for self-protection. Flatpack MPSU 12 kW is available in 48
and 60 VDC configurations.
Typical applications
• UMTS and GSM Base Stations
• Digital Loop Carrier (DLC)
• E911 (Public Safety)
• Microwave
• Digital Subscriber Line
• Telephone Switches• Internet Hubs
• Co-location
KEY FEATURES
System
• Max. number of rectifiers: 8• Input voltage:
- 1 phase 230 VAC- 3 phase 230 VAC ( )- 3 phase 400 VAC+N ( Y )
• Frequency: 45 to 66Hz• Operating temperature: -40 to +60°C
(-40 to +140°F)• Storage temperature: -40 to +85°C
(-40 to +185°F)• Dimensions (wxdxh):
482 x 300 x 312mm (7U)/19 x 11.8 x 12.3"• Weight: approx. 16kg (36lbs) excl. rectifiers
Rectifier
• Flatpack 1500
Monitoring Unit
• Flatpack MCU
DC Distribution
• Up to 4 battery MCBs and 19 load MCBs• Programmable LVD:
- Standard/1 LVBD (max. 250 Amps)- Optional/1 LVLD (max. 250 Amps)
Applicable standards
• Safety: EN 60950, UL 60950• EMC:
- ETSI EN 300 386 V.1.3.1 (telecom.network)
- EN 61000-6-3 (emission, light industry)- EN 61000-6-2 (immunity, industry)
• Environment:- ETSI EN 300 019-2- ETSI EN 300 132-2
Approvals
• CE-markedFlatpack MPSU 12 kW
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 15/72
15
Flatpack PRSB 9000
KEY FEATURES
System
• Max. number of rectifiers: 6• Input voltage:
- 1 phase 230 VAC- 3 phase 230 VAC ( )- 3 phase 400 VAC+N ( Y )
• Frequency: 45 to 66Hz• Operating temperature: -40 to +60°C
(-40 to +140°F)• Storage temperature: -40 to +85°C
(-40 to +185°F)• Dimensions (wxdxh):
- 600 x 600 x 630mm/23.6 x 23.6 x 24.8"- 600 x 600 x 900mm/23.6 x 23.6 x 35.4"- 600 x 600 x 1800mm/23.6 x 23.6 x 70.9"
• Weight: approx. excl. rectifiers- 630mm/35kg (77lbs)- 900mm/40kg (88lbs)- 1800mm/70kg (154lbs)
Rectifier
• Flatpack 1500
Monitoring Unit
• Flatpack MCU
DC Distribution
• Up to 4 battery MCBs and 19 load MCBs• Programmable LVD:
- Standard/1 LVBD (max. 250 Amps)
- Optional/1 LVLD (max. 250 Amps)
Applicable standards
• Safety: EN 60950• EMC:
- ETSI EN 300 386 V.1.3.1 (telecom.network)
- EN 61000-6-3 (emission, light industry)- EN 61000-6-2 (immunity, industry)
• Environment:- ETSI EN 300 019-2- ETSI EN 300 132-2
Approvals
• CE-marked
Description
The Flatpack PRSB 9000 has been specifically designed to meet the
demand for higher density and more compact power solutions. It is
suitable for applications needing an expandable, easily serviceable and
reliable power supply, fitting within a minimal space. The Flatpack PRSB
9000 is a compact power system containing a Monitoring and Control Unit
(MCU), LVD, battery and load MCBs. It can house up to six Flatpack 1500
rectifier modules, is capable of handling up to 250 Amps and may be
delivered in different indoor floor cabinets according to the required
battery size. The system accepts large variations in the input voltage anddraws sinusoidal current with a soft start power-up. The Flatpack PRSB
9000 will operate at full power in ambient temperatures up to +60°C
(+140°F). At higher temperatures, each rectifier will derate the output
power for self-protection. Flatpack PRSB 9000 is available in 24, 48 and
60 VDC configurations.
Typical applications
• UMTS and GSM Base Stations
• Digital Loop Carrier (DLC)
• E911 (Public Safety)
• Microwave• Digital Subscriber Line
Flatpack PRSB 9000
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 16/72
Flatpack PRSB 15 kW
KEY FEATURES
System
• Max. number of rectifiers: 10• Input voltage:
- 1 phase 230 VAC- 3 phase 230 VAC ( )- 3 phase 400 VAC+N ( Y )
• Frequency: 45 to 66Hz• Operating temperature: -40 to +60°C
(-40 to +140°F)• Storage temperature: -40 to +85°C
(-40 to +185°F)• Dimensions (wxdxh):
- 600 x 600 x 1500mm/23.6 x 23.6 x 59"- 600 x 600 x 1800mm/23.6 x 23.6 x 70.9"- 600 x 600 x 2000mm/23.6 x 23.6 x 78.7"- 600 x 600 x 2200mm/23.6 x 23.6 x 86.6"
• Weight: approx. excl. rectifiers- 1.5m/75kg (165lbs)- 1.8m/85kg (187lbs)- 2.0m/92kg (203lbs)- 2.2m/97kg (214lbs)
Rectifier
• Flatpack 1500
Monitoring Unit
• Flatpack MCU
DC Distribution
• Up to 27 load MCBs and up to 3 battery NH2
• Programmable LVD: 1 LVBD (400 Amps)
Applicable standards
• Safety: EN 60950, UL 60950• EMC:
- ETSI EN 300 386 V.1.3.1 (telecom.network)
- EN 61000-6-3 (emission, light industry)- EN 61000-6-2 (immunity, industry)
• Environment:- ETSI EN 300 019-2- ETSI EN 300 132-2
Approvals
• CE-marked
Description
The Flatpack PRSB 15 kW has been designed to meet the demand for
higher DC power capacity and the requirements for telecommunication
applications including mobile phone networks. The Flatpack PRSB 15 kW
contains the Monitoring and Control Unit (MCU), LVBD, temperature sensor,
integrated DC distribution, battery MCBs and battery compartments. The
PRSB 15 kW can house up to ten Flatpack 1500 rectifier modules and
may be delivered in different indoor floor cabinets according to the
required battery size (up to 400 Ah/48 VDC).
The system accepts large variations in the input voltage and draws
sinusoidal current with a soft start power-up. The system is supplied via
a single or three phase configurable input connection. The Flatpack PRSB
15 kW will operate in ambient temperatures up to +60°C (+140°F).
At higher temperatures, each rectifier will derate the output power for
self-protection. Flatpack PRSB 15 kW is available in 24, 48 and 60 VDC
configurations.
Typical applications
• UMTS & GSM Base Stations
• Digital Loop Carrier (DLC)• E911 (Public Safety)
• Telephone Switches
• Data Center
• Internet Hubs
• Optical Switches
• Co-location
• GSM Backbone Stations
Flatpack PRSB 15 kW
2 and 4 battery banks
16
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 17/72
17
Flatpack PRSB 21 kW
KEY FEATURES
System
• Max. number of rectifiers: 14• Input voltage:
- 1 phase 230 VAC- 3 phase 230 VAC ( )- 3 phase 400 VAC+N ( Y )
• Frequency: 45 to 66Hz• Operating temperature: -40 to +60°C
(-40 to +140°F)• Storage temperature: -40 to +85°C
(-40 to +185°F)• Dimensions (wxdxh):
- 600 x 600 x 1500mm/23.6 x 23.6 x 59"- 600 x 600 x 1800mm/23.6 x 23.6 x 70.9"- 600 x 600 x 2000mm/23.6 x 23.6 x 78.7"- 600 x 600 x 2200mm/23.6 x 23.6 x 86.6"
• Weight: approx. excl. rectifiers- 1.5m/80kg (177lbs)- 1.8m/90kg (199lbs)- 2.0m/97kg (214lbs)- 2.2m/102kg (225lbs)
Rectifier
• Flatpack 1500
Monitoring Unit
• Flatpack MCU
DC Distribution
• Up to 27 load MCBs
• Up to 2 load NH2 (max. 400 Amps)• Up to 4 battery NH2 (max. 400 Amps)• Programmable LVD: 1 LVBD (max. 400 Amps)
Applicable standards
• Safety: EN 60950, UL 60950• EMC:
- ETSI EN 300 386 V.1.3.1 (telecom.network)
- EN 61000-6-3 (emission, light industry)- EN 61000-6-2 (immunity, industry)
• Environment:- ETSI EN 300 019-2- ETSI EN 300 132-2
Approvals
• CE-marked
Description
The Flatpack PRSB 21 kW has been designed to meet the demand for
higher DC power capacity. The Flatpack DC power systems are specifically
designed to meet the requirements for telecommunication applications
including mobile phone networks. The Flatpack PRSB 21 kW contains the
Monitoring and Control Unit (MCU), LVBD, temperature sensor, integrated
DC distribution, battery circuit breakers and battery compartments. The
PRSB 21 kW can house up to 14 Flatpack 1500 rectifier modules and may
be delivered in different indoor floor cabinets according to the required
battery size (up to 400 Ah/48 VDC).
The system accepts large variations in the input voltage and draws
sinusoidal current with a soft start power-up. The Flatpack PRSB 21 kW
will operate in ambient temperatures up to +60°C (+140°F). At higher
temperatures, each rectifier will derate the output power for self-
protection. Flatpack PRSB 21 kW is available in 24, 48 and 60 VDC
configurations.
Typical applications
• UMTS & GSM Base Stations
• Digital Loop Carrier (DLC)• E911 (Public Safety)
• Telephone Switches
• Data Center
• Internet Hubs
• Optical Switches
• Co-location
• GSM Backbone Stations
Flatpack PRSB 21 kW
1 and 3 battery banks
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 18/72
Flatpack PRSB 30 kW
18
Flatpack PRSB 30 kW
KEY FEATURES
System
• Max. number of rectifiers: 20• Input voltage:
- 1 phase 230 VAC- 3 phase 230 VAC ( )- 3 phase 400 VAC+N ( Y )
• Frequency: 45 to 66Hz• Operating temperature: -40 to +60°C
(-40 to +140°F)• Storage temperature: -40 to +85°C
(-40 to +185°F)• Dimensions (wxdxh):
- 600 x 600 x 1500mm/23.6 x 23.6 x 59"- 600 x 600 x 1800mm/23.6 x 23.6 x 70.9"- 600 x 600 x 2000mm/23.6 x 23.6 x 78.7"- 600 x 600 x 2200mm/23.6 x 23.6 x 86.6"
• Weight: approx. excl. rectifiers- 1.5m/88kg (194lbs)- 1.8m/98kg (216lbs)- 2.0m/105kg (231lbs)- 2.2m/110kg (242lbs)
Rectifier
• Flatpack 1500
Monitoring Unit
• Flatpack MCU
DC Distribution
• Up to 27 load MCBs
• Up to 2 load NH3 (max. 630 Amps)• Up to 4 battery NH3 (max. 630 Amps)• Programmable LVD: 1 LVBD (max. 600 Amps)
Applicable standards
• Safety: EN 60950, UL 60950• EMC:
- ETSI EN 300 386 V.1.3.1 (telecom.network)
- EN 61000-6-3 (emission, light industry)- EN 61000-6-2 (immunity, industry)
• Environment:- ETSI EN 300 019-2- ETSI EN 300 132-2
Approvals
• CE-marked
Description
The Flatpack PRSB 30 kW has been designed to meet the demand for
higher DC power capacity. The Flatpack DC power systems are specifically
designed to meet the requirements for telecommunication applications
including mobile phone networks.
The Flatpack PRSB 30 kW contains the Monitoring and Control Unit (MCU),
LVBD, temperature sensor, integrated DC distribution, battery CB and battery
compartments. The PRSB 30 kW can house up to 20 Flatpack 1500 rectifier
modules and may be delivered in different indoor floor cabinets accordingto the required battery size (up to 400 Ah/48 VDC).
The system accepts large variations in the input voltage and draws sinuso-
idal current with a soft start power-up. The Flatpack PRSB 30 kW will
operate in ambient temperatures up to +60°C (+140°F). At higher
temperatures, each rectifier will derate the output power for self-protection.
Flatpack PRSB 30 kW is available in 24, 48 and 60 VDC configurations.
Typical applications
• UMTS & GSM Base Stations
• Digital Loop Carrier (DLC)• E911 (Public Safety)
• Telephone Switches
• Data Center
• Internet Hubs
• Optical Switches
• Co-location
• GSM Backbone
Stations
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 19/72
Flatpack Wallbox 3000
19
FlatpackWallbox 3000
KEY FEATURES
System
• Max. number of rectifiers: 2• Input voltage:
- 1 phase 230 VAC• Frequency: 45 to 66Hz• Operating temperature: -40 to +70°C
(-40 to +158°F)• Storage temperature: -40 to +85°C
(-40 to +185°F)• Dimensions (wxdxh):
333 x 114 x 440mm/13.1 x 4.5 x 17.3"• Weight: approx.
- 8kg (17.6lbs) excl. rectifiers- 12.5kg (27.5lbs) incl. rectifiers
Rectifier
• Flatpack 700• Flatpack 1500
Monitoring Unit
Wallbox FMA unit• Local operation: Alarm reset• Alarm relays: 3 programmable outputs• Visual indications:
- Green LED – Power ON- Red LED – Active alarm(s)- LCD – system information
• Current measurement: Battery current• Alarms:
- Load fuse alarm
- Module alarm- Mains failure- Battery fuse alarm- High battery temperature (2 levels)- Low battery temperature (2 levels)- Low output voltage (2 levels)- High output voltage (2 levels)
DC Distribution
• One battery MCB and up to 5 load MCBs• Programmable LVD:
- 48 VDC/1 x 60 Amps- 24 VDC/1 x 120 Amps
Applicable standards
• Safety: EN 60950• EMC:
- ETSI EN 300 386 V.1.3.1(telecom. network)- EN 61000-6-3 (emission, light industry)- EN 61000-6-2 (immunity, industry)
• Environment:- ETSI EN 300 019- ETSI EN 300 132-2
Approvals
• CE-marked
Description
The Flatpack Walbox 3000 has been designed for smaller applications
requiring a compact and economical solution. It includes standard alarms
and functions for this application and is a very cost effective alternative.
The Flatpack Wallbox 3000 is a compact and flexible power system
including a built-in monitoring unit, input MCB, battery and load MCBs.
The Flatpack Wallbox 3000 can house up to two Flatpack 1500 rectifier
modules giving output power of 3000 W/ 48 VDC or 2700 W/ 24 VDC.
The Flatpack Wallbox 3000 will operate in ambient temperatures up to+70°C (+158°F). At higher temperatures, the rectifier will derate the
output power and deliver the maximum possible power until it goes into
an over-temperature shutdown.
Typical applications
• Private Automatic Branch Exchange (PABX)
• Digital Subscribe Line
• Micro Cell Base Stations
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 20/72
20
FlatpackPower Tower
KEY FEATURES
System
• Max. number of rectifiers: 6• Input voltage:
- 1 phase 230 VAC- 3 phase 230 VAC ( )- 3 phase 400 VAC+N ( Y )
• Frequency: 45 to 66Hz• Operating temperature: -40 to +60°C
(-40 to +140°F)• Storage temperature: -40 to +85°C
(-40 to +185°F)• Dimensions (wxdxh):
300 x 600 x 1800mm (38U)/11.8 x 23.6 x 70.8"• Weight: approx. 66kg (143lbs) excl.
rectifiers and batteries
Rectifier
• Flatpack 700• Flatpack 1500
Monitoring Unit
• Flatpack MCU
DC Distribution options
• Up to 15 load MCBs• Up to 2 battery MCBs• Programmable LVD:
- Standard/1 LVBD (max. 200 Amps)- Optional/1 LVLD (max. 200 Amps)
Applicable standards
• Safety: EN 60950, UL 60950• EMC:
- ETSI EN 300 386 V.1.3.1(telecom. network)
- EN 61000-6-3 (emission, light industry)- EN 61000-6-2 (immunity, industry)
• Environment:- ETSI EN 300 019-2- ETSI EN 300 132-2
Approvals
• CE-marked
Description
The Flatpack Power Tower has been designed to limit the occupied floor
space where this is either limited or expensive, thus significantly reducing
the lifetime cost of the installation.
The Power Tower is a compact slim-line power rack system containing a
Monitoring and Control Unit (MCU), LVD, battery and load MCBs. It can
house up to six Flatpack 1500 rectifier modules and 200Ah of battery
capacity. The system accepts large variations in the input voltage and
draws sinusoidal current with a soft start power-up.
The Flatpack Power Tower will operate in ambient temperatures up to
+60°C (+140°F). At higher temperatures, each rectifier will derate the
output power for self-protection. Flatpack Power Tower is available in 24,
48 and 60 VDC configurations.
Typical applications
• UMTS and GSM Base Stations
• Digital Loop Carrier (DLC)
• Fiber Repeater• E911 (Public Safety)
• Microwave
• Digital Subscriber Line
Flatpack Power Tower
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 21/72
21
MPSU 200
KEY FEATURES
System
• Max. number of rectifiers: 6 or 8• Input voltage:
- 1 phase 230 VAC• Frequency: 45 to 66Hz• Operating temperature: -10 to +55°C
(14 to +131°F)• Storage temperature: -40 to +85°C
(-40 to +185°F)• Dimensions (wxdxh):
482 x 267 x 134mm (3U)/19 x 10.5 x 5.3"
• Weight: approx. 8kg (17.6lbs) excl.rectifiers
Rectifier
• SMPS 200
Monitoring Unit
• AL 175NT
Distribution
• Up to 6 load MCBs (2-40 Amps)• Up to 14 load fuses (glass) (5 or 10 Amps)
Applicable standards
• Safety: EN 60950, UL 60950• EMC:
- ETSI EN 300 386 V.1.3.1(telecommunication network)
- EN 61000-6-3 (emission, light industry)- EN 61000-6-2 (immunity, industry)
• Environment:- ETSI EN 300 019-2- ETSI EN 300 132-2
Approvals
• CE-marked
Description
The MPSU 200 is a rack mountable DC Standby Power Solution designed
for integration within customer equipment racks, typically in Access
Network applications. These applications require a scaleable, expandable,
easily serviceable and reliable power solution.
The different plug-in distributions, single output (front connection), 6-way
MCB (top connection) or 14-way glass fuse (front connection), allows
either 6 x 200 W (6 or 14 way distribution) or 8 x 200 W (single distri-
bution) SMPS 200 rectifier units. All distribution units allow input fromtwo separate battery banks via two 30 Amps MCBs. The AL 175NT alarm
unit controls the LVBD to prevent deep discharge of the batteries.
Typical applications
• Point of Presence (POPs)
• Digital Loop Carrier (DLC)
• Fiber Repeater
• E911 (Public Safety)
• Small Microwave
• Digital Subscriber Line
• Micro Cell Base Stations
MPSU 200 with glass fuses
MPSU 200 with external distribution
MPSU 200 with MCB distribution
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 22/72
22
MPSU 4000
KEY FEATURES
System
• Input voltage:- 1 phase 230 VAC- 3 phase 230 VAC ( )- 3 phase 400 VAC+N ( Y )
• Dimensions (wxdxh):482 x 280 x 267mm (6U)/19 x 11 x 10.52"
• Weight: approx. 8kg (17.6lbs) excl.rectifiers
Rectifier
• SMPS 1000
Monitoring Unit
• AL 175NT
Distribution
• Up to 10 load circuit breakers (2-50 Amps)• One battery MCB (100 Amps)• LVBD unit controlled by timer or voltage• LVLD unit controlled by timer or voltage
Applicable standards
• Safety: EN 60950, UL 60950• EMC:
- EN 61000-6-3 (emission)- EN 61000-6-2 (immunity, industry)- EN 300 386-2 (immunity)
• Network Rail Certificate of Acceptance
Approvals
• CE-marked
Description
The MPSU 4000 is a rack mountable power system prepared for integration
into telecommunication equipment racks. The MPSU 4000 contains DC
distribution, AL 175NT monitoring control unit and up to four SMPS 1000
plug-in rectifier modules providing up to 4000 W DC power.
The highly reliable and versatile AL 175NT provides a comprehensive
range of monitoring and control features. Together with the flexible internal
DC distribution, the MPSU 4000 can be tailored to meet most needs in
telecommunications applications in the low power range. Rectifiers andmonitoring units are UL-recognized components. The Following options
are possible: temperature probe for temperature compensated charging,
load disconnect unit, battery disconnect unit, modem and external SNMP
agent. MPSU 4000 is available in 24, 48 and 60 VDC configurations.
Typical applications
• Point of Presence (POPs)
• Digital Loop Carrier (DLC)
• Fiber Repeater
• E911 (Public Safety)
• Small Microwave• Digital Subscriber Line
• Cellular Base Stations
MPSU 4000
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 23/72
23
MPSU 5000
KEY FEATURES
System
• Input voltage:- 1 phase 230 VAC- 3 phase 230 VAC ( )- 3 phase 400 VAC+N ( Y )The input terminals are configurable on-siteto any of the above mains configurations
• Dimensions (wxdxh):533 x 375 x 267mm/ETSI /21 x 14.75 x 10.5"
• Weight: 12.5kg (27.6lbs) excl. rectifiers
Rectifier
• SMPS 1000
Monitoring Unit
• AL 175NT
Distribution
• Option 1:- 4 load MCBs (2-63 Amps)- 2 load MCBs (80 Amps)- one battery MCB (250 Amps)
• Option 2:- 4 load MCBs (2-63 Amps)- one load MCB (160 Amps)- one battery MCB (250 Amps)
• LVBD controlled by timer or voltage• Other distribution configurations may
be constructed upon request
Applicable standards
• Safety: EN 60950• EMC:
- EN 61000-6-3 (emission)- EN 61000-6-2 (immunity, industry)- EN 300 386-2 (immunity)
• Environment:- ETSI EN 300 019-2-1- ETSI EN 300 019-2-2- ETSI EN 300 019-2-3
Approvals
• CE-marked
Description
The MPSU 5000 is a rack mountable power system prepared for integration
into telecommunication equipment racks. The MPSU 5000 contains DC
distribution, AL 175NT monitoring control unit and up to five SMPS 1000
plug-in rectifier modules providing up to 5000 W DC power. The 21" (ETSI)
wide and 6U high system is a modular concept that allows expansion and
service without power shut down and increases system reliability.
The highly reliable and versatile AL 175NT provides a comprehensive
range of monitoring and control features. The MPSU 5000 is available inthree different system voltages: 24 VDC/192 Amps, 48 VDC/105 Amps or
60 VDC/83 Amps. The DC distribution has one or two large load outputs,
up to four additional small load outputs and a fused battery connection. It
provides an ideal configuration for one or two Radio Base Station cabinets
that require a single DC feed. The Rectifiers and monitoring unit are UL-
recognized components. The Following options are possible: temperature
probe for temperature compensated charging, battery disconnect unit,
modem and external SNMP agent. MPSU 5000 is available in 24, 48 and
60 VDC configurations.
Typical applications• Point of Presence (POPs)
• Digital Loop Carrier (DLC)
• Fiber Repeater
• E911 (Public Safety)
• Small Microwave
• Cellular Base Stations
• 3G
MPSU 5000
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 24/72
24
MPSU 6000
KEY FEATURES
System
• Max. number of rectifiers: 6• Input voltage:
- 1 phase 230 VAC- 3 phase 230 VAC ( )- 3 phase 400 VAC+N ( Y )The input terminals are configurable on-siteto any of the above mains configurations
• Dimensions (wxhxd):533 x 375 x 445/ETSI /21 x 14.75 x 17.5"
• Weight: 12.5kg (27.6lbs) excl. rectifiers
Rectifier• SMPS 1000
Monitoring Unit
• AL 175NT
Distribution
• Up to 16 load MCBs (2-63 Amps)• Up to 2 NH00 (max. 160 Amps)• LVBD controlled by timer or voltage• LVLD controlled by timer or voltage• Other external distribution options are
available
Applicable standards
• Safety: EN 60950• EMC:
- EN 61000-6-3 (emission)
- EN 61000-6-2 (immunity, industry)- EN 300 386-2 (immunity)
• Environment:- ETSI EN 300 019-2
• Network Rail Certificate of Acceptance
Approvals
• CE-marked
Description
The MPSU 6000 is a rack mountable power system prepared for integration
into telecommunication equipment racks. MPSU 6000 contains DC distri-
bution, AL 175NT monitoring control unit and up to six SMPS 1000 plug-in
rectifier modules providing up to 6000 W DC power. The 21" (ETSI) wide
system is a modular concept that allows expansion and service without
power shut down and increases the reliability. Eltek can provide custom
made solutions utilizing enclosures that house the MPSU 6000, batteries
and all associated equipment.
The MPSU 6000 is available in three different system voltages: 24 VDC/231
Amps, 48 VDC/126 Amps or 60 VDC/100 Amps.
The highly reliable and versatile AL 175NT provides a comprehensive range
of monitoring and control features. Together with the flexible internal DC
distribution, the MPSU 6000 can be tailored to meet most needs in
telecommunications applications in the medium power range. The rectifiers
and monitoring unit are UL-recognized components. The following options
are possible: temperature probe for temperature compensated charging,
load disconnect unit, battery disconnect unit, modem and external SNMP
agent. MPSU 6000 is available in 24, 48 and 60 VDC configurations.
Typical applications
• Point of Presence (POPs)
• Digital Loop Carrier (DLC)
• Fiber Repeater
• E911 (Public Safety)
• Small Microwave
• Cellular base stations
• 3G
MPSU 6000
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 25/72
25
PRS 700
KEY FEATURES
System
• Max. number of rectifiers: 21• Input voltage:
- 1 phase 230 VAC- 3 phase 230 VAC ( )- 3 phase 400 VAC+N ( Y )The input terminals are configurable on-site toany of the above mains configurations
• Dimensions (wxdxh):- 600 x 400 x 1800-2200mm (6U)/
ETSI /21" x 15.75 x 70.87-86.61"- 600 x 600 x 1800-2200mm (6U)/
ETSI /21" x 23.62 x 70.87-86.61"
Rectifier
• SMPS 1000
Monitoring Unit
• AL 175NT
Distribution
• Option 1:- Up to 6 NH00 (160 Amps)- Up to 27 load MCBs (2-50 Amps)
• Option 2:- Up to 2 NH2 (250 Amps)- Up to 27 load MCBs (2-50 Amps)
• A wide range of customized distributionsolutions, such as High Ohmic Distributionand others that differ from our standard
configurations are available.
Applicable standards
• Safety: EN 60950• EMC:
- EN 61000-6-3 (emission)- EN 61000-6-2 (immunity, industry)- EN 300 386-2 (immunity)
• Network Rail Certificate of Acceptance
Approvals
• CE-marked
Description
The PRS 700 AC to DC power system is a complete rack including up to
21 rectifiers, an AL 175NT monitoring unit and distribution. A common
system design forms a flexible basis that can be configured to meet most
requirements in the medium power range. The modular concept with
plug-in rectifiers and rectifier shelves offers system solutions in three
different power levels: 7 kW, 14 kW and 21 kW, with respectively one,
two and three rectifier shelves mounted. The wide range of cabinet
solutions includes various distribution options with or without internal
battery back-up. Internal battery back-up is dependent on the number of rectifier shelves. The system is equipped with the AL 175NT monitoring
and control unit that offers a comprehensive range of monitoring and
control features. The rectifiers and the monitoring unit are UL-recognized
components. The following options are possible: external SNMP agent,
temperature probe for temperature compensated charging, load
disconnect unit, battery disconnect unit and modem.
Typical applications
• Point of Presence (POPs)
• TETRA
• Cellular Base Stations• Amplifier Sites
PRS 700
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 26/72
26 AEON 4000
AEON 4000
KEY FEATURES
System
• Max. number of rectifiers: 96(in standard system)
• Input voltage:- 1 phase 230 VAC- 3 phase 230 VAC ( )- 3 phase 400 VAC+N ( Y )
• Max. power 3 PR system:- 24 VDC/20 kW per shelf, 750 Amps,
60 kW per cabinet, 2250 Amps- 48 VDC/24 kW per shelf, 510 Amps,
72 kW per cabinet, 1530 Amps
- 60 VDC/24 kW per shelf, 346 Amps,72 kW per cabinet, 1190 Amps• Total front access• Dimensions (wxdxh):
600 x 600 x 2000mm/23.62 x 23.62 x 78.74"• Battery shelves can be integrated
Rectifier
• SMPS 4000
Monitoring Unit
• AEON Gold
Distribution
• Option 1:- Up to 6 NH3 (630 Amps)- Up to 27 load circuit breakers
(max. 63 Amps)
• Option 2:- Up to 2 NH00 six NH3 (630 Amps)- Up to 54 load circuit breakers
(max. 63 Amps)• Option 3:
- Front access plug-in circuit breakerdistribution panel
- 24 breakers (max. 100 Amps each)• LVBD or LVLD are available
Approvals
• CE-marked• UL-recognition of SMPS 4000 and
AEON Gold• NEBS Level 3 certified
Description
The AEON 4000 power system is one of the most advanced and compact
DC Power systems on the market. Consisting of 4000 W rectifier modules
and an AEON Gold control and monitoring unit. It represents a perfect
choice for applications within the medium to high power applications.
Total system power ranges from 24 kW to 72 kW in a single cabinet, but
in total, it is possible to get output power up to 384 kW. AEON 4000
power system is available in 24, 48 and 60 VDC configurations.
Larger systems require separate rectifier cabinets and DC distributioncabinets. The AEON 4000 AM is specifically configured for the require-
ments of North and South American customers.
Typical applications
• Telephone Switches
• Data Center
• Internet Hubs
• Optical Switches
• Co-location
• Fixed Net Backbone sites
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 27/72
27
SVS system
KEY FEATURES
System
• Max. number of rectifiers per rectifiercabinet:- SVS 48/60V - 750/600A/3- SVS 48/60V - 1250/1000A/5, system
expandable with parallelable cabinets upto > 10 000 Amps
- SVS 48/60V - 2500/2000A/10, systemexpandable with parallelable cabinets upto > 10 000 Amps
• Input voltage: 400 VAC• Frequency: 45 to 65 Hz
• Operating temperature: -10 to +45°C(-14 to +113°F), full power +60°C (140°F)with derating
• Storage temperature: -40 to +85°C(-40 to +185°F)
• Dimensions (wxdxh):- SVS 48/60V - 750/600A/
600 x 600 x 2000mm/23.6 x 23.6 x 78.7"- SVS 48/60V - 1250/1000A/
1400 x 600 x 2000mm/55.2 x 23.6 x 78.7"- SVS 48/60V - 2500/2000A/
2000 x 600 x 2000mm/78.7 x 23.6 x 78.7"• Weight: fully equipped
- SVS 48/60V - 750/600A/315 kg (694.5lbs)
- SVS 48/60V - 1250/1000A/519kg (1144.2lbs)
- SVS 48/60V - 2500/2000A/
889kg (1959.9lbs)
Rectifier
• RM 14400 Type: D60/200WBrug - 2 GRM
Monitoring Unit
SVS-SM5/SVS-SP1• Input voltage: 24 VDC/48 VDC/60 VDC• Buttons for data request and adjustments• Display of measured values and error reports• Communications interfaces: Internal
(controller)/ analog + RS 485, External(service laptop)/ RS 232
• Remote alarm: Modem, SNMP, TCP/IP• Event storage• Characteristics: Float charging /Boost
charging
• Load voltage regulation• Temperature compensation battery voltage• DC-Voltage/Current displays• Voltage monitors: Battery/Load:
Over voltage/Under voltage• Battery discharge protection control• Battery charging current limit• Battery availability test (total battery)• Battery balance monitoring• System data: Serial number, rated voltage,
others• LCD display/buttons• Expandable by means of external signaling
modules• Operating status signals: LED,
Telecommunications signals (urgent, noturgent)
Continues on the next page...
Description
The RM 14400 rectifier module is the basic component for building large
Power supply system with three phase input. This 14.4 kW rectifier
(48 VDC/250 Amps or 60 VDC/200 Amps) is fan cooled and operates
from 230/400 VAC, 3 phase input. Up to five 250 Amps rectifiers can be
installed in one GRS 1250 Power Rack. Each rack delivers up to 1250
Amps. The power racks can be used in parallel operation simply by
connecting the integrated DC copper bus with the next rack. Furthermore,
the standard Battery and Distribution Rack (BVS 1250 and BVS 2500)
offers all the connections required for battery and load outlets as well asenough space to integrate an optional LVD.
The system comprises a Micro Processor Controller Unit, which is pro-
grammable with the integrated 3-button keyboard or with an external
laptop computer. All required interfaces, using volt free contacts, RS-232
and RS-485, are standard. For remote control purposes the power supply
can optionally be equipped with a modem (analogue, ISDN and GSM). It
is possible to apply remote control using our SNMP/ TCP/IP Ethernet
adapters.
A typical 2500 Amps System consists of two GRS 1250 power racks andone BVS 2500, two Battery Fuses (2 x 1250 Amps each) and enough
space for Power Outlets are available. The whole SVS system design is
fully digital and highly modular. It is possible to build systems greater
than 10 000 Amps as well as to extend existing systems under full load
conditions if required. Several versions, such as the SVS 750 with an
integrated DC distribution for medium power, are also available.
Typical applications
• DSL and SDH Networks
• Telephone Switches
• Large Fiber Repeaters• Data Center and Internet Hubs
• Optical Switches
(Refer to pictures on the next page...)
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 28/72
28
Continues from previous page...
• Faults:- System fault (centralized signal)- Rectifier fault- Redundancy monitoring- Battery/Load voltage fault- Battery availability test fault- Battery unbalance- Battery deep discharge- Temperature fault- Mains failure- Voltage monitoring- Fuse monitoring- Signaling of site-based signal
(freely available): optionally expandable• Potential free contacts:
- Fault- Mains failure- Boost charging characteristic
(ventilator control)- Others: optionally expandable
DC Distribution options
• Standard configurations available up to750 Amps/1250 Amps/2500 Amps capacityrespectively.
• Regional adaptations to local requirements areavailable.
• Customized solutions can be engineered uponrequest.
Applicable standards• Safety: EN 60950, class 1• EMC:
- EN 61000-6-3 (emission)- EN 61000-6-2 (immunity)
• Environment:- ETSI EN 300 019-2- ETSI EN 300 132-2
• Protection class: IP20, EN 60529
Approvals
• CE- marked
SVS 2500 with additional AC-rack NV 630
Power supply system
SVS 750
NV 630 GRS 1250 BVS 2500 GRS 1250
SVS system: Refer to text on the previous page...
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 29/72
29
PDU 19" MCBdistribution 24 way
Description
The PDU Power Distribution Unit 250 Amps 3U/19" DC distribution has
been specifically designed to meet the demand for smaller and more
compact power solutions. It is suitable for applications needing an
expandable, easily serviceable and reliable DC distribution fitting within
a minimal space.
The PDU 3U/19" DC distribution is a very compact distribution which can
house up to 24 standard 17mm wide fuses.
Typical applications
PDU Power Distribution Unit is used in 19" DC distribution systems. This
unit may be combined with AC input circuit breakers and a lightning
protection unit.
KEY FEATURES
• Voltage: 24 VDC/48 VDC/60 VDC• Max. current: 250 Amps• 24 load breakers Siemens 5SX and 5SY series
(max. 63 Amps)• Load MCB connections:
- Negative: directly in the breakers- Positive: common positive bus bars
(positive distribution on request)• Alarm detections: Diode matrix on top of fuse
rail
Other specifications
• Operating temperature: -40 to +70°C(-40 to +158°F)• Storage temperature: -40 to +85°C
(-40 to +185°F)• Dimensions (wxdxh):
483 x 33 x 140mm (3U)/19 x 1.3 x 5.5"• Weight: approx. 2.2kg (4.8lbs) excl. fuses
Approvals
• CE- marked
PDU 19" MCB distribution 24 way
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 30/72
30
DCD 22 Way and40 Way with LVBD
Description
The Eltek DC Distribution Unit has been designed to operate with AC to
DC rectifiers and a standby battery. The flexible unit design allows
connection to various types of power solutions operating at a nominal
–48 VDC.
Typical applications
Customer equipment cabinets (Broadband and Access Network
applications).
KEY FEATURES
Operation
DCD 22 Way with LVBD• 22 Way Load Distribution via 5 Amp Glass
Fuses• Connection to Rectifier/Battery Charger and
Battery• Auxiliary Connection for additional input/output• LVBD• Battery over-ride• External control/alarm
DCD 40 Way with LVBD
• 40 Way Load Distribution via 5 Amp GlassFuses• Connection to Rectifier and Battery• LVBD• Alarm and control
General
DCD 22 Way with LVBD• Rating: all connections are rated at 45 Amps• Dimensions (wxdxh):
485 x 45 x 220mm (plus 50mm for rearconnection cables)/19 x 1.77 x 8.66" (plus 1.96")
• Weight: 2kg (4.4lbs)
DCD 40 Way with LVBD• Rating: all connections are rated at 63 Amps• Dimensions (wxdxh):
485 x 89 x 200mm (plus 70 mm for rearconnection cables)/19 x 3.5 x 7.87" (plus 2.75")
• Weight: 2.5kg (5.5lbs)
Approvals
• CE-marked
DC Distribution Unit 22 way
DC Distribution Unit 40 way
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 31/72
DCD 4000 system
Description
Eltek can provide tailor-made, large capacity DC Distribution plants from
their range of standard building blocks. The modular construction of the
distribution units allow customer specific panels to be made quickly and
cost efficient. Systems are rated from 2000 to 8000 Amps (96 kW to
384 kW) and are used in conjunction with the AEON 4000 product range.
A typical DCD 4000 distribution system will consist of a Master Control
Cubicle, DC Distribution cabinets and optional cable management bays.
The Master Control cubicle provides individual fused inputs for connectingrectifier cabinets and parallel connecting battery banks. The rating of the
battery fusing can be fitted to match the standby requirements and will
support autonomy periods from one to eight hours. This cubicle will also
contain the AEON Gold alarm module and will therefore provide a single
point for all control and monitoring functions.
Each Master Control Cubicle can connect to up to four distribution cabinets.
Each distribution cabinet is built to accept up to eight plug-in distribution
units (PIDU). The customer can plug-and-play with the various PIDU
options therefore making installation and expansion flexible and easy. In
a variety of applications the size and number of outgoing cables are largedue to voltage drop restraints. Installation and expansion is therefore
made easier by the deployment of adjacent cable management bays.
Low voltage disconnect is available through the use of Eltek’s Battery
Disconnect Unit (BDU), which aids installation and maintenance. These
distribution plants often support secondary distribution panels such as the
Eltek PDU. The overall system will support both under floor and overhead
cabling with top and bottom cable access. The systems can also be
configured to work in dual feed – “A” and “B” feed systems in accordance
with site-specific requirements.
Typical applications• Telephone Switches
• Data Centers
• Internet Hubs
• Co-location
KEY FEATURES
Operation
Master Distribution Cabinets• AEON Gold control unit and all I/O interfaces• Fused inputs for AEON 4000 rectifier cabinets• Fused inputs rated up to 1250 Amps for
battery banks
Distribution Cubicles
• Up to 8 PIDU positions that can be madeup of the following options: 18 x plug-in DCcircuit breakers rated up to 100 Amps,1 x 800, 1000, 1250 or 1600 Amps blade fuse,
2 x 400 or 630 Amps Blade Fuse, 3 x 100,160 or 250 Amps Blade Fuse, 1 x 240, 480,600, 800, 1250 or 1600 Amps MCCB, 3 x 125or 160 Amps MCCB
• Customer specific panels available uponrequest
• Cable Management Bays fit adjacent toDistribution cubicles
General
• Dimensions per cubicle/bay (wxdxh):600 x 600 x 2000mm/23.62 x 23.62 x 78.74"
• Cable management cabinets may have half width (wxdxh):300 x 600 x 2000mm/11.81 x 23.62 x 78.74"
Approvals
• CE-marked
DCD 4000 system31
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 32/72
32
PDU
Description
The Power Distribution Unit, PDU, provides a dual bay “A” and “B” –
DC distribution unit to provide diverse feeds to load equipment such as
telecommunications switching and transmission.
The PDU offers a dual input rack rated at 600 Amps for each input, which
support up to 40 circuit breakers, rated from 5 to 100 Amps. The cabinet
uses plug-in circuit breakers to facilitate installation and expansion. The
PDU is designed as a secondary distribution cabinet in medium to large
power applications.
The inputs are fed via switched isolators whilst a unique cable management
facilitates output cable installation for either top or bottom exit, thus allowing
safe and easy expansion. Both local and remote monitoring is provided
with metering of voltage, bay current, input supply fail and breaker trip.
The unit can also be configured to provide a single 1200 Amp, 80 Way
distribution cabinet.
Typical applications
Facilitating a fully redundant “A” and “B” distribution system it fits intoapplications where the power
quality is absolutely essential.
• Telephone Switches
• Data Centers
• Internet Hubs
• Co-location
KEY FEATURES
Operation
• Input voltage: -48 VDC Nominal, total range:40-60 VDC
• Input current: 600 Amps per feed; 1200 Ampsas a single product
• Input protection: Isolator link, fuse availableupon request
• Input connections:4 x M12 per feed - Negative8 x M12- Common Return
• Output fusing: 40 Way plug in circuit breakerper feed, 5 to 100 Amps
• Output connections: up to 35mm2
(2 AWG) viatwo hole cable lug-Negative M6 stud-CommonReturn
• Alarm types: MCB Fail A, MCB Fail B, Input FailBay A, Input Fail Bay B
• Alarm indication: volt free contact and red LEDindication
• Metering: system voltage and current for bothfeeds
General
• Dimensions (wxdxh):600 x 600 x 2200mm/23.6 x 23.6 x 86.6"
• Weight: 125kg (275.6lbs)
Approvals
• CE-marked
PDU
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 33/72
33
BDU
Description
The Eltek wall mounted battery isolator/disconnect unit is designed to
provide automatic battery disconnection to prevent deep discharge damage
of batteries. This is achieved by the activation/de-activation of a contactor
by an external control signal provided by the AEON Gold control and
monitoring unit.
Typical applications
The BDU 1000 is suitable in applications where a safe low voltage battery
disconnection is required and a number of parallel battery strings areapplied. Normally the BDU 1000 is mounted on the battery stand and
provides disconnection and isolation facilities for individual battery strings.
Up to twelve BDUs 1000 can work in parallel, controlled by the same
AEON Gold unit. The BDU can be used with other power systems if
required. The unit is especially well suited on sites with high power and
long back-up times, requiring a number of large capacity battery strings
to be paralleled. This includes:
• Co-location
• Telecom Centers
• Internet Backbone Sites
KEY FEATURES
Operation
• Voltage: -48 VDC Nominal, 40-60 VDC totalrange
• Maximum current: 1000 Amps• Fusing: Single blade fuse,
400-630-800-1000 Amps• Manual override: the BDU will normally be
controlled by a contactor feed signal fromthe AEON Gold. A manual override control isavailable to lock the contactor in the ‘closed’ position
• Manual isolate: a manual isolate switch will
disconnect the contactor for maintenance.• Alarm Outputs: The BDU produces alarmsignals for contractor tripped/failed and fusefail that can be fed back via the AEON Gold.
• Indicators:- Green LED: BDU healthy and in operation- Red LED: Contactor is open. Battery
disconnected- Green and Red LED together: BDU in manual
override
General
• Dimensions (wxdxh):450 x 250 x 600mm/17.7 x 9.7 x 23.6"
• Weight: 22kg (48.5lbs)
Approvals
• CE-marked
• Safety: EN 60950
BDU
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 34/72
34
All Eltek core elements, including rectifiers, converters and system
monitors, are approved for worldwide applications including UL, CE
and NEBS recognition and approval.
This section of our catalog details various system solutions that have
been designed to incorporate UL related approvals at a system level
as well.
Eltek has created many different system designs for applications
throughout the world. A key element that often differentiates system
design is the adherence to local safety agency regulations and
listings.
One of the most common safety agency listings, especially for systemsused within the United States, is Underwriters Laboratories Inc or
“UL”. Adherence to UL and other requirements are needed to
demonstrate regulatory and market requirements. If UL certification
is required for your application please select a solution from the
following pages. If your ideal system is not displayed in this section,
please contact your nearest Eltek representative so we can develop
a solution tailored to your specific needs.
UL-recognized DC Power systemsand DC Distribution products
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 35/72
35
DCD 125APFlatpack system
Description
The DCD 125AP is a 125 Amps Flatpack system with a 1U distribution
device and up to two Flatpack power racks. The DCD 125AP is the
smallest in both size (1U) and current rating (125 Amps) of the Flatpack
systems. This particular device has a single battery input protected by
a circuit breaker rated up to 125 Amps and large main load output
protected by a circuit breaker rated up to 125 Amps. This distribution
device also offers twelve GMT load fuse positions rated up to 15 Amps
each.
The DCD 125AP has optional contactors for battery disconnect, or load
disconnect. It has two current shunts to monitor battery and load current
and a place to plug-in the MCU controller for the Flatpack rectifiers.
This compact system is ideally suited for small cabinetized applications
but can also be mounted into a standard relay rack or indoor cabinet.
This system is ideal for loads up to 6 kW.
Typical applications
• UMTS and GSM Base Stations
• Point of Presence (POPs)• Digital Loop Carrier (DLC)
• Fiber Repeater
• E911 (Public Safety)
• Small Microwave
• Digital Subscriber Line
KEY FEATURES
Operation
• Compact size (1U, 19")• Max. total current: 125 Amps• One large battery breaker
(max. 125 Amps)• One large breaker load output
(max. 125 Amps)• 12 GMT fuse outputs- max. fuse size 15 Amps,
maximum rating of GMT fuse block 60 Amps.• This system accommodates up to 4 Flatpack
rectifiers, and 2 PRs.• Optional battery disconnect contactor
• Optional load disconnect contactor:(disconnects the large breaker output)• 6 alarm relays
Rectifier
• Flatpack 700• Flatpack 1500
Monitoring Unit
• Flatpack MCU
General
• Full system dimensions (wxdxh):439 x 304 x 121mm/17.3 x 11.95 x 4.75"
• Weight: max. 4.7kg (10.4lbs) excl. the MCU,max. 5.4kg (11.9lbs) incl. the MCU
• Connections: rear• Operating temperature: -40 to +70°C
(-40 to +158°F)
Approvals
• CE-marked• UL-recognized UL 1950• NEBS Level 3 certified
DCD 125AP Flatpack system
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 36/72
36
DCD 3FM-200AFlatpack system
Description
The DCD 3FM-200A is a 200 Amps Flatpack power system that includes a
3U distribution unit and up to three Flatpack power racks. The DCD 3FM-
200A is a completely front access unit with a maximum current rating
of 200 Amps. This particular device has fourteen plug-in overcurrent
protection devices that can be either fuses or breakers. These plug-in
overcurrent protection devices can be configured for combinations of
either battery or load distribution.
The DCD 3FM-200A has optional contactors for battery disconnect, loaddisconnect and a combination of both for load shedding. It has two current
shunts to monitor battery and load current and a place to plug-in the
MCU controller for the Flatpack rectifiers. This compact system is ideally
suited for small cabinetized applications but can also be mounted into a
standard relay rack or indoor cabinet. This system is ideal for loads up to
9 kW.
Typical applications
• UMTS and GSM Base Stations
• Point of Presence (POPs)
• Digital Loop Carrier (DLC)• Fiber Repeater
• E911 (Public Safety)
• Small Microwave
• Digital Subscriber Line
KEY FEATURES
Operation
• Compact size (3U, 19")• Max. total current: 200 Amps• Up to 4 battery breakers• Up to 12 load breakers• This system accommodates up to
6 Flatpack rectifiers, and 3 PRs.• Optional LVBD• Optional LVLD• 6 alarm relays
Rectifier
• Flatpack 700• Flatpack 1500
Monitoring Unit
• Flatpack MCU
General
• Full system dimensions (wxdxh):439 x 320 x 267mm/7.3 x 12.6 x 10.5"
• Weight: 21.7kg (48lbs)• Connections: front access• Operating temperature: -40 to +70°C
(-40 to +158°F)
Approvals
• CE-marked• UL-recognized UL 1950• NEBS Level 3 certified
DCD 3FM-200A Flatpack system
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 37/72
37
400A/600AFlatpack system
KEY FEATURES
System
• Max. number of rectifiers: 14 (7 PRs)• Compact size (400A/600A in 12U,
19 or 23")• Max. total current: 600 Amps• Eleven alarm relays• Operating temperature: -40 to +60°C
(-40 to +140°F)• Dimensions full system 400A (wxdxh):
- 439 x 368 x 533mm/17.3 x 14.5 x 21.0"- with rear covers/
439 x 379 x 533mm/17.3 x 14.9 x 21.0"
• Weight: 74.84kg (165lbs)• Connections: rear and front
Rectifier
• Flatpack 700• Flatpack 1500
Monitoring Unit
• Flatpack MCU
DC Distribution options
• Up to 8 battery breakers• Up to 24 load breakers• Optional LVBD• Optional LVLD
Approvals
• CE-marked
• UL-recognized UL 60950• NEBS Level 3 certified
Description
The 400A/600A Flatpack system is a 4U distribution unit designed to work
with the Flatpack rectifier systems. The 400A/600A is a front and rear
access unit with a current rating of 400 Amps or 600 Amps. The distri-
bution unit accepts plug in breakers. The 19" version houses 20 breakers
and the 23" version houses 24 breakers.
The 1U MCU panel has 400 Amps shunts for both battery and load monitor-
ing. The MCU holder has front access connection for all control and
monitoring functions and a slot to plug in the MCU. A 2U MCU panel ratedfor 600 Amps with all the above same attributes is also available.
The 400A/600A has optional contactors for battery disconnect, load
disconnect and both for load shedding. The system can be configured for
both battery and load breakers and accepts plug in fuses as well. If more
distribution is required, another breaker panel can be easily added.
This compact system is ideally suited for small cabinetized applications
but can also be mounted into a standard relay rack or indoor cabinet. This
system is ideal for loads up to 21 600 W.
Typical applications
• UMTS and GSM Base Stations
• Point of Presence (POPs)
• Digital Loop Carrier (DLC)
• Fiber Repeater
• E911 (Public Safety)
• Small Microwave
• Digital Subscriber Line
400A Flatpack system
600A Flatpack system
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 38/72
38
FlatpackCabinetized system
KEY FEATURES
System
• Max. number of rectifiers: 20 (10 PRs)• Max. total current: 600 Amps• Eleven alarm relays• Connections: front• Operating temperature: -40 to +60°C
(-40 to +140°F)• Dimensions (wxdxh):
610 x 610 x 2134mm/24 x 24 x 84"• Weight: 170kg (375lbs) (typical)
Rectifier
• Flatpack 700• Flatpack 1500
Monitoring Unit
• Flatpack MCU
Distribution
• Up to 8 battery MCBs and up to 24 load MCBs• Optional LVBD• Optional LVLD
Approvals
• CE-marked• UL-recognized UL 60950• NEBS Level 3 certified
Description
The Flatpack Cabinetized Power system is a complete cabinet including
up to twenty rectifiers, control module and distribution. A common
system design forms a flexible basis that can be configured to meet
most requirements in the medium power range. The modular concept
with plug-in rectifiers and rectifier shelves offers system solutions in
many different configurations.
The system can accommodate up to 72 plug-in load breakers or fuses,
contactors for battery and load, and many different battery distributionoptions. The cabinets come in both non-seismic and seismic rated
(Telcordia GR-63-CORE Zone 4).
Typical applications
• Point of Presence (POPs)
• Large Fiber Repeater
• Telephone Switches
• Data Center
• Internet Hubs
• Optical Switches
• Co-location• Cellular Base Station
• Fixed Net Backbone Sites
Flatpack Cabinetized system
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 39/72
39
TwinPack Plus®Power system
KEY FEATURES
System
The 5U (8.75") high, 23" rack mount DCdistribution unit has high volumetric efficiency,with the following features integrated bydesign:
• Max. number of rectifiers: 12 (max. 3 PRs)• Spacious AC input junction box with
terminal block supporting single AC feed perrectifier
• Current measuring resistive shunts, formonitoring of rectifier, battery, and load
currents• Front access alarm relay connections(10 software-configurable Form C relays)
• Battery symmetry and temperaturemonitoring
• Three-tier load shedding via the LVDcontactors
• Two-hole lug connections on all DC load andreturn bus bar positions
• Master Battery EPO / Remote Disconnectcapability via 600A battery contactor
• Operating temperature: -40 to +70°C(-40 to +158°F)
• Dimensions (wxdxh):718 x 610 x 2134mm/29.25 x 24 x 84"
• Weight: 214.5kg (473lbs)
Rectifier
• TwinPack Plus® RC rectifier
Monitoring Unit
• Flatpack MCU
DC Distribution options
• Plug-in DC load breakers and fuses;single and multi-pole variants supported
• LVBD and LVLD options
Applicable standards
• Telcordia GR-63-CORE Zone 4 qualifiedseismic rack and battery trays are standard
Approvals
• CE-marked• UL-recognized UL 60950
• NEBS Level 3 certified
Description
The TwinPack Plus® power system is a modular DC power product
utilizing the proven TwinPack Plus® switch mode rectifier. These power
systems meet –48 VDC power system requirements of up to 600 Amps -
and are scalable to grow with changing system requirements. This new
TwinPack Plus® system leverages the new TWPP-RC rectifier and the
Flatpack MCU to provide updated features of the Flatpack rectifier
systems to those who prefer the TWPP rectifier form factor.
The result is a completely self-contained, battery-backed DC power plant- in a single rack footprint. Optional load shedding architecture and a
modular load distribution unit provide extended battery back-up time
compared to other systems. Rectifier output voltage is automatically
controlled by the MCU and does not require periodic re-adjustment. The
MCU is hot swappable in a live system without affecting the system’s
ability to deliver charge and load current.
Individual battery disconnect circuit breakers are provided at each battery
tray. Individual battery strings may be disconnected for maintenance
without affecting the system load. Integrated temperature compensated
charge control and battery symmetry monitoring serve to maximizebattery life and protect against battery damage.
Typical applications
• UMTS and GSM Base Stations
• Point of Presence (POPs)
• Digital Loop Carrier (DLC)
• Fiber Repeater
• E911 (Public Safety)
• Small Microwave
• Digital Subscriber Line
TwinPack Plus® Power system
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 40/72
40
AEON 4000 AMSingle Cabinet system
AEON 4000 AM
KEY FEATURES
System
• Max. number of rectifiers: 18• AC Inputs:
- 3 phase (3 or 4 wire) 480 VAC- 3 phase (4 wire) 400/380 VAC- 3 phase (3 wire) 230 VAC- 3 phase (3-wire) 208 VAC
• Max. total current: 2250 Amps (24 VDC)and 1530 Amps (48 VDC)
• Dimensions (wxdxh): 610 x 610 x 2134mm/24 x 24 x 84"
• Weight: depends on cabinet configuration,
typical range 136kg (300lbs) to 227kg(500lbs))• Connections: Front• Operating temperature: -10 to +50°C
(+14 to +131°F)
Rectifier
• SMPS 4000
Monitoring
• AEON Gold
Distribution
• Up to 8 battery breakers• Up to 24 load breakers• Optional LVBD• Optional LVLD
Approvals
• CE-marked• UL-recognition of SMPS 4000 and
AEON Gold• NEBS Level 3 certified
Description
The AEON AM power system provides a complete, high quality DC power
solution for medium to high power applications. The AEON AM system is
based around the SMPS 4000 rectifier module, a compact 4000 W rectifier
module designed to provide a high power density in a small size. This
American version of the AEON system encloses all power system compon-
ents in a single power rack design. The system configurations allow for up
to eighteen SMPS 4000 rectifier modules to be contained in one
cabinet, giving a total power output range of 4 kW to 72 kW. Within each
power system, the SMPS 4000 rectifier modules are controlled andmonitored by a microprocessor based controller called the AEON Gold.
The AEON Gold monitoring unit can be accessed locally by a user-friendly
LCD screen and keypad. The AEON Gold can also be accessed via
WinPower, a Windows based software developed by Eltek Energy. Using
this interface makes the set up of AEON AM less complicated and much
quicker. The AEON AM can also accommodate remote access communi-
cation through SNMP or TCP/IP protocols. The AEON AM Power system
also offers versatile features such as: up to 72 plug-in breaker/fuse posi-
tions, large scale distribution or
battery protection devices rated to800 Amps, DC/DC converters with
independent distribution options, and
LVD functionality for battery, load, or
load shedding. Telcordia GR-63-CORE
Zone 4 rated cabinets are available.
Typical applications
• Point of Presence (POPs)
• Large Fiber Repeater
• Telephone Switches
• Data Center• Internet Hubs
• Optical Switches
• Co-location
• Cellular base station
• Fixed Net Backbone Sites
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 41/72
41
High CurrentAEON systems
KEY FEATURES
System
• Max. number of rectifiers: 96• Distributive or Centralized Architecture• AC Inputs:
- 3 phase (3 or 4 wire) 480 VAC- 3 phase (4 wire) 400/380 VAC- 3 phase (3 wire) 230 VAC- 3 phase (3-wire) 208 VAC
• Max. total current: up to 8160 Amps• Max. power: up to 384 kW• Dimensions (wxdxh): per cabinet
610 x 610 x 2134mm/24 x 24 x 84"
• Weight: depends on cabinet configuration,typical range 227kg (500lbs) to 317.5kg(750lbs) per cabinet
• Connections: front• Operating temperature: -10 to +50°C
(+14 to +131°F)
Rectifier
• SMPS 4000
Monitor
• AEON Gold
Distribution
• Primary Load and Battery Distribution• Optional LVBD• Optional LVLD• Secondary Load Distribution
Approvals
• CE-marked• UL-recognition of SMPS 4000 and
AEON Gold• NEBS Level 3 certified
Description
The high current AEON 4000 Power system is a multi-cabinet, high
capacity power system available in –48 VDC. System sizes can range
from 1200 Amps up to 10 000 Amps and can be configured using
either centralized or distributed architecture.
The centralized architecture is described as a system that consists of
rectifier cabinets, primary load distribution cabinets and primary battery
distribution cabinets all connected in series. All the copper bus work for
the system must be rated for the maximum current rating of the system.This system provides the user the ultimate of flexibility on how the
batteries and loads are connected into the DC Power system.
The distributive architecture is described as a system of many cabinets
connected together. Each cabinet has rectifiers; primary load distribution
and battery load distribution collocated in each cabinet. Up to six cabinets
can be connected in series to provide more current for the user. The real
benefit of this system is the smaller copper bus bars required. The largest
amperage connection required between cabinets is the maximum current
of a single cabinet. A recent upgrade to AEON Gold software allows Eltek
to offer distributive architecture with SMPS 4000 rectifiers.
Typical applications
• Point of Presence (POPs)
• Large Fiber Repeater
• Telephone Switches
• Data Center
• Internet Hubs
• Optical Switches
• Co-location
• Cellular Base Station
• Fixed Net Backbone Sites
High Current AEON systems
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 42/72
42
4U Plug-in PDU
KEY FEATURES
Operation
• 1-100 Amps single pole breakers, 125-175Amps two-pole breakers and 200-250 Ampsthree-pole breakers, fuses single pole 1-100Amps.
• Tin-plated copper bus bars• 600 Amps• Two-hole lugs for load and ground returns• Top cable entry• Top and rear cover options
General
• Dimensions (wxdxh):511 x 379 x 160mm/20.1 x 14.9 x 6.3"• Weight: 13.5kg (29.75lbs)
4U Plug-in PDU
Description
The Plug-in PDU provides power distribution with plug-in breakers and/or
fuses for up to 24 circuits in only 4U of rack space. The Plug-in PDU
accepts circuit breakers or fuses. Connections are made with two-hole
lugs on both the load and ground return. The panel is rated for a
maximum of 600 Amps and can be configured for either a single bus or
split bus “A” and “B” arrangement.
Local indication is provide by a front panel red LED that illuminates when
a device is tripped. One set of Form C contact provides remote alarmindication. The 23" mount unit provides 24 breakers and the 19" version
provides 16 positions. Rear covers can be orders as an option.
Plug-in Distribution Devices
The PDU offers the convenience and versatility of Plug-in distribution
devices. Plug-in breakers are offered in single pole up to 100 Amps,
double pole up to 175 Amps and triple pole up to 250 Amps. The larger
breakers can utilize an expansion bus to allow larger gauge wires to be
terminated. If fuses are preferred, a single pole fuse holder is available
and will accommodate TLS type fuses rated from 5 Amps to 100 Amps.
All alarming is accomplished by detecting auxiliary contact changes onthe back of the distribution devices.
Typical applications
• Telephone Switches
• Data Center
• Internet Hubs
• Co-location
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 43/72
KEY FEATURES
Operation
• Six 24-position circuit breaker/fuse distributionpanels
• 1-100 Amps single pole breakers,125-175 Amps two-pole breakers and200-250 Amps three-pole breakers, fusessingle pole 1-100 Amps
• Tin-plated copper bus bars• 650 Amps• Two-hole lugs for load and ground returns• Bottom or top cable entry• Isolation pad to isolate the enclosed rack
frame from the floor• Top cover option
Mechanical Information
• Dimensions (wxdxh):610 x 610 x 2134mm/24 x 24 x 84"
• Weight:- seismic cabinet fully loaded 219.5kg
(484lbs)- non-seismic cabinet fully loaded 199kg
(439lbs)
144 Position Plug-in PDU
144 PositionPlug-in PDU
Description
The 144 Position Plug-in PDU is designed to distribute and monitor DC
loads to various types of telecommunication equipment. Typically utilized
as a secondary distribution point, it can be installed directly or adjacent
to the DC Power system, or deployed at another remote point in the
installation. The 144 Position Plug-in PDU comes in seismic or non-seismic
cabinets and accepts either fuses or breakers for the distribution devices.
There are a total of 144 distribution points divided into six, 24 position
breaker/fuse sections that can be separated into either two redundantfeeds, four redundant feeds or six redundant feeds. Each input is rated for
650 Amps, and is designed for a maximum of an 800 Amps fuse/breaker
feed.
Optional Digital Meter
An optional digital meter is available to measure current in each bus and
each breaker/fuse panel. The optional digital meter panels mounts on the
front door and has an LED display (xxx.x). It measures two bus currents
(“A” and “B”), main battery voltage and up to six branch currents Full scale
and zero offset adjustment potentiometers are provided and accessible
from the rear of the panel.
Plug-in Distribution Devices
The 144 Position PDU offers the convenience and versatility
of Plug-in distribution devices. Plug-in breakers are offered
in single pole up to 100 Amps, double pole up to 175 Amps,
and triple pole up to 250 Amps. The larger breakers utilize an
expansion bus to allow larger gauge wires to be terminated.
If fuses are preferred, a single pole fuse holder is available
and will accommodate TLS type fuses rated from 5 Amps to
100 Amps. Each breaker that is plugged into the 144 Position
Plug-in PDU is individually alarmed to the alarm bus, usingthe built in contacts on the back of the breaker.
Typical applications
• Telephone Switches
• Data Center
• Internet Hubs
• Co-location
43
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 44/72
44
GMT Fusedistribution
Description
The GMT fuse panel provides power distribution and current protection for
small loads. These panels are 1U in height, 19" rack mount with a depth
of 3". The units come in three varieties: 10 fuses, 10A/10B or 20A/20B.
These units also come in both 24 and 48 VDC. Each of the GMT type fuse
holders accommodates from a 1 to 15 Amps fuse. Maximum output
current rating for the panel is 120 Amps (65 Amps per bus). Remote
alarm (Form C contacts) and a visual alarm (red LED) are provided for
any fuse failure. A green LED indicates that input power is present. The
panel ’s wide operating temperature range makes it suitable for mostindoor and outdoor environments.
Typical applications
• Point of Presence (POPs)
• Digital Loop Carrier (DLC)
• Fiber Repeater
• E911 (Public Safety)
• Small Microwave
• Cellular base stations
• 3G
• Data Center• Co-location
KEY FEATURES
Operation
• Available in 24 VDC and -48 VDC• Two isolated groups of GMT Fuses• Major/Minor Alarm Contacts• 120 Amps of Output Current (65 Amps
max. per bus)
General
• Single 44mm (1.75") mounting height (1U)• Reversible brackets for 482mm (19") and
584mm (23") rack mounting• Panel depth 76mm (3")
Approvals
• UL-recognized UL 1801• NEBS Level 3 certified
GMT Fuse distribution
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 45/72
45
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 46/72
46
Rectifiers and converters
This section outlines the switchmode power supplies offered by Eltek. The rectifier will always be the
core component, the "heart" of a DC Power system. Eltek therefore devotes much of its R&D efforts to
the development of new state of the art designs, which have the quality and the functionality expected
in modern telecommunications business.
Eltek offers single phase rectifier modules with output power from 200 W to 4 kW and three phase
rectifier modules at 14.4 kW per module. All are hot plug-in units intended for parallel operation in a
DC Power system. Normally they serve as a combination of power supply and battery charger, but they
can also be utilized in applications where batteries are not present, supplying high quality DC power.
As a truly global company we seek to fulfill the most stringent requirements throughout the world
especially with regard to the input voltage range. Most rectifiers have active power factor correction
making the mains distortion minimal.
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 47/72
47
RECTIFIERS AND CONVERTERS
Flatpack 700 and 1500 ................ 48
Slimpack ................................... 50
SMPS 200 .................................. 51
SMPS 1000 ................................ 52
TwinPack Plus® .......................... 53
SMPS 4000 ................................ 54
RM 14400 .................................. 55
Flatpack DC/DC converter ............ 56
For small and medium systems we offer following rectifiers: The SMPS
200 is a 200 W convection cooled rectifier that operates at 230 VAC
input. Flatpack 700 is a fan-cooled rectifier providing 700 W power for
universal input voltage range. When more power is needed the SMPS
1000, a 1000 W convection cooled rectifier that operates from a 230 VAC
input, is an option. Eltek’s Flatpack 1500 compact rectifier provides
complete flexibility by offering 1500 W output at 230 VAC. The TwinPack
Plus® rectifier is available in a 1500 W version for operation in 120 VAC
systems, and a 3000 W version for operation with 240 VAC input.
For large systems the SMPS 4000, a 4000 W fan-cooled rectifier can be
utilized. All rectifiers have load-sharing features independent of any
monitoring and control unit. This optimizes an already long lifetime
(MTBF) expected for our rectifiers. We also have a three phase option in
the 14.4 kW module, RM 14400.
Slimpack is a rectifier designed by Eltek Energy especially for stand-alone
use.
The Flatpack DC/DC is a modular hot plug-in DC/DC converter prepared
for stand-alone use, or for working in parallel as part of a DC/DC racksystem.
Through our affiliations with major Universities specializing in power
electronics in both Europe and the US, we are in the forefront of new
technologies. As we continue to develop our switching techniques, we
are able to improve the efficiency of our rectifiers and increase the power
density. The density is also improved through better thermal manage-
ment. Either natural or forced convection accomplishes efficient cooling of
the rectifiers. All rectifiers developed by Eltek are CE and UL marked. In
addition, we seek to comply with National standards. Furthermore, we
strive to design products that not only comply to high quality standardsand customer demands, but also represent the best in power supplies on
the market.
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 48/72
48
Flatpack 700and 1500
KEY FEATURES
Input
• Input operating voltage: 85-310 VAC• Frequency: 45 to 66 Hz• Max. Current:
- Flatpack 1500 24 VDC/8.5 Armsmax. at 185 VAC and 1350 W output
- Flatpack 1500 48 VDC/9.2 Armsmax. at 185 VAC and 1500 W output
- Flatpack 1500 60 VDC/9.2 Armsmax. at 185 VAC and 1500 W output
- Flatpack 700 48 VDC/7.5 Armsmax. at 110 VAC, 3.6 Arms
max. at 230 VAC• Power factor:> 0.99 at 50% load or more• Input protection: Soft start, Surge protection
(varistors), Internal fuses (L & N), Automaticdisconnect above 310 VAC
Output
• Voltage:- 24 VDC/range: 20-29.5 VDC- 48 VDC/range: 44-59 VDC- 60 VDC/range: 50-70 VDC
• Output power:- Flatpack 1500 24 VDC /1350 W- Flatpack 1500 48 VDC/1500 W- Flatpack 1500 60 VDC/1500 W- Flatpack 700 48 VDC/700 W
universal input• Maximum current:
- Flatpack 1500 24 VDC/50 Amps at 27 VDC- Flatpack 1500 48 VDC/31.25 Amps at
48 VDC- Flatpack 1500 60 VDC/25 Amps at 60 VDC- Flatpack 700 48 VDC/15 Amps at 48 VDC
• Hold up time: 20ms• Efficiency:
- Flatpack 1500 24 VDC/> 88%- Flatpack 1500 48 VDC/> 90%- Flatpack 1500 60 VDC/> 90%- Flatpack 700 48 VDC/> 88% at 110 VAC,
> 90% at 230 VAC
General
• Rectifier alarm:- Mains failure- Module failure,
- Over voltage shutdown- Fan Failure• Visual indications:
- Green LED: ON, no faults- Red LED: Rectifier failure- Green LED bargraph: 10 LEDs showing
load current• Operating temperature: -40 to +70°C
(-40 to +158°F)• Storage temperature: -40 to +85°C
(-40 to +185°F)• Cooling: two fans (front to back airflow),
brushless w/ magnetic bearing• MTBF: > 210 000 hours Telcordia Issue I,
method III (a)
Continues on the next page...
Description
The compact fan-cooled Flatpack 700 and 1500 rectifiers are designed to
endure any extreme operating conditions that can be expected in
telecommunication installations and industrial applications. Minimum size,
a universal input voltage range, wide operating temperature, high
immunity against surges and overvoltage are key features incorporated
into the Flatpack 700 and 1500.
The Flatpack 700 and 1500 are rectifiers for stand-alone use or parallel
operation in a power rack system. Its very high power density, costefficient design and ability to accept a wide input voltage range and tough
ambient conditions, makes it the perfect choice in any telecom network.
Two Flatpack rectifiers can be plugged into a 1U high, 19" wide and
293mm (11.5") deep power shelf providing 1400 W (Flatpack 700), 2700 W
(Flatpack 1500 24 VDC) or 3000 W (Flatpack 1500 48 VDC) DC power.
Multiple Power Racks may be combined and paralleled to achieve the
required amount of DC power. The Flatpack rectifier modules can also be
mounted vertically. When connected in parallel, the rectifiers provide
active current sharing independent of the Monitoring and Control Unit.
Switchmode technology with soft switching and high switching frequency
is used to minimize volume and weight and to obtain fast output voltage
regulation. The module accepts large variations of the input voltage and
draws sinusoidal current with a soft start power-up.
Typical applications
The rectifier is used in Flatpack Power systems.
(Refer to pictures on the next page...)
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 49/72
49
Continues from previous page...
• Acoustic Noise: < 55dBA• Dimensions (wxhxd):
214 x 41.5 x 243mm/8.43 x 1.64 x 9.57"• Weight: 2.8kg (6.17lbs)
Applicable standards
• Safety: EN 60950, UL 60950• EMC:
- ETSI EN 300 386 V.1.3.1(telecommunication network)
- EN 61000-6-3 (emission, light industry)- EN 61000-6-2 (immunity, industry)- Telcordia GR-1089-CORE
• Harmonics: EN 61000-3-2• Environment:
- ETSI EN 300 019-2- ETSI EN 300 132-2- Telcordia GR-63-CORE Zone 4
Approvals
• CE-marked• UL-recognized• NEBS Level 3 certified
Flatpack 700
Flatpack 1500 24 VDC
Flatpack 1500 48 VDC
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 50/72
50
Slimpack
KEY FEATURES
Input
• Input operating voltage: 85 -310 VAC• Frequency: 45 to 66 Hz• Max. current: 8.4 Arms max. at 150 VAC
and 1130 W output• Power Factor:> 0.99 at 50% load or more
Output
• Output voltage: 54.5 VDC (range 40-58 VDC)• Output power: 1130 W• Max. current: 10 Amps at 85-150 VAC, up
to 20 Amps at 150-300 VAC
• Hold up time: 20ms• Efficiency:> 90% at full load
General
• Rectifier alarms:- Input voltage derating- Temperature derating- Over voltage shutdown- Current limit operation,- Fan failure
• Visual indications:- Green LED: ON, no faults- Red LEDs:
Rectifier failureMains abnormalBattery polarity reversedLVBD disconnected
• Potentiometers:
- LVBD threshold- Float voltage- Max. Battery Recharge current- Equalize voltage
• Operating temperature: -40 to +70°C(-40 to +158°F), no derating -40 to +55°C(-40 to +131°F)
• Storage temperature: -40 to +85°C(-40 to +185°F)
• Cooling: two fans (back to front airflow), brushlessw/ magnetic bearing
• Fan Speed: temperature regulated.• MTBF:> 210 000 hours Telcordia Issue I,
method III (a)• Acoustic Noise: < 60dBA at 100% fan speed• I/O terminals: 0.08-2.5mm2 /28-12 AWG• Relay terminals: 0.14-0.5 mm2 /26-20 AWG
• Dimensions (wxhxd):- excl. brackets/300 x 44.5 x 283mm/11.83 x 1.75 x 11.1"
- assembly/482.5 x 44.5 x 283mm/19 x 1.75 x 11.1"
- ETSI assembly/548 x 44.5 x 283mm/21.5 x 1.75 x 11.1"
• Weight: 3kg (6.6lbs)
Applicable standards
• Safety: EN 60950, UL 60950• EMC:
- ETSI EN 300 386 V.1.3.1(telecommunication network)
- EN 61000-6-3 (emission, light industry)- EN 61000-6-2 (immunity, industry)
• Harmonics: EN 61000-3-2• Environment: ETSI EN 300 019-2, ETSI EN 300 132-2
Approvals
• CE-marked
Description
The Slimpack is an AC/DC converter and battery charger/rectifier for
stand-alone use. It is a switchmode power supply designed for battery
charging and supplying high quality DC power to telecom equipment and
similar applications. Switchmode technology with soft switching and high
switching frequency is used to minimize volume and weight and to obtain
fast output voltage regulation. The module accepts large variations in the
input voltage and draws sinusoidal current with a soft start power-up.
The controller card contains a mains sense circuit, battery contactor,reverse battery polarity protection and battery current limit circuit.
Modern, yet well-proven technology makes the Slimpack a compact and
reliable power supply. In addition, a wide range of features are integrated.
Typical applications
The rectifier is used for all DC power requirements where a N+1 solution
is not required, typically powering equipment such as:
• Digital Subscriber Line
Slimpack
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 51/72
51
SMPS 200
Description
The SMPS 200 is a rectifier and battery charger for parallel operation with
redundancy as part of a power rack system controlled by the AL 175NT
alarm module. The SMPS 200 is based on a "hot plug-in" design using
convection cooling technology. As a result of the "hot plug-in" capability,
installation and service are easy to perform.
Switchmode technology with high switching frequency is used to mimimize
volume and weight, and to obtain fast output voltage regulation. The
module accepts large variations in the input voltage and draws sinusoidalcurrent with a soft start power-up. When working in parallel, the rectifiers
provide active current sharing.
Typical applications
The rectifier is used in the MPSU 200 Power Systems, typically powering
equipment such as:
• Point of Presence (POPs)
• Digital Loop Carrier (DLC)
• Fiber Repeater
• E911 (Public Safety)
• Small Microwave• Digital Subscriber Line
• Micro Cell Base Station
KEY FEATURES
Input
• Input operating voltage: 230 VAC ± 20%single phase
• Frequency: 45 to 65 Hz• Power factor: 0.7 typical
Output
• Voltage: 48 VDC nominal, adjustable between45 to 58 VDC
• Output power: 200 W• Max. current: 3.8 Amps at 53.5 VDC• Current share: ±5% of full load current
• Hold-up time: > 10ms• Efficiency: > 88%
General
• Volt free alarm: common output operatedunder one of the following conditions- Module failure,- Low input voltage- High output voltage shut down
• Visual indication: Green LED: Unit healthy• Operating temperature: -10 to + 55°C
(+14 to +131°F)• Storage temperature: -25 to +85°C
(-93 to +185°F)• Cooling: convection• MTBF: > 700 000 hours• Dimensions (wxhxd):
35.5 x 128.4 (3U) x 220 mm/1.4 x 5 x 8.7"
• Weight: < 1.5kg (< 3.3lbs)
Applicable standards
• Safety: EN 60950• EMC:
- EN 61000-6-3 (emission, light industry)- ETS 300 386-2 (emission)- EN 61000-6-2 (immunity, industry)- ETS 300 386-2 (immunity)
• Harmonics: EN 61000-3-2
Approvals
• CE-marked
SMPS 200
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 52/72
52
SMPS 1000
Description
The SMPS 1000 is a battery charger and rectifier for stand-alone use or
for working in parallel as part of a Power Rack system controlled by the
AL 175NT monitoring/control unit. The SMPS 1000 is used in a wide range
of Eltek Power systems and is proven to be a highly reliable rectifier
module with natural convection cooling.
Switchmode technology with soft switching and high switching frequency
is used to minimize volume and weight, and to obtain fast output voltage
regulation. The module accepts large variations in the input voltage anddraws sinusoidal current with a soft start power-up. For measuring the
output current, LED indicators, voltage adjustment and test bushings are
available on the rectifier’s front panel.
Typical applications
The rectifier is used in the MPSU 4000, 5000, 6000 and PRS 700 Power
systems, typically powering equipment such as:
• Point of Presence (POPs)
• Digital Loop Carrier (DLC)
• Fiber Repeater
• E911 (Public Safety)• Small Microwave
• Cellular base stations
• 3G
• TETRA
• Amplifier Sites
KEY FEATURES
Input• Input operating voltage:
- 150-205 VAC, 730 W- 205-275 VAC, 1000 W
• Frequency: 45-66 Hz, single phase• Max. current: 5.5 Amps• Power Factor: > 0.99
Output• Voltage:
- 24 VDC/11 VDC to 30 VDC adjustable,internal over voltage protection: 30 VDC
- 48 VDC/40 VDC to 58 VDC adjustable,internal over voltage protection: 59.5 VDC
- 60 VDC/Voltage: 50 VDC to 72 VDC adjustable,Internal over voltage protection: 73.5 VDC
• Max. current:- 24 VDC/37 Amps (920 W +/-20 W at
26.8 VDC)- 48 VDC/21 Amps (1000 +/-20 W at 54 VDC)- 60 VDC/16.7 Amps (1000 +/-20 W at 66.9 VDC)
• Hold-up time: > 10ms• Efficiency: > 91%
Operation• Automatic over temperature derating for increased
reliability• Input for external shutdown signal• Constant output power and current limitation for fast
battery recharge and safe operation• Visual indications:
- Green LED: Power ON/OFF- Red LED: Module alarm
- Yellow LED: Current limit operation• Rectifier alarm output, activated by internal failure• Plug-in connection facilitating easy service and
maintenance without load interruption• Power factor corrected input providing reduced
harmonics and minimal input power requirements• MTBF: 433,944 Bellcore IIIb, +25°C (77°F)• Cooling: convection• Operating temperature: -10 to +70°C (+14 to
+158°F), output power derating occurs at approx.+40°C (+104°F) depending on the airflow inside thecabinet
• The SMPS 1000 supports the following control functions:- Remote output voltage adjust for temperature
compensation, boost charging and battery testing- Active current sharing for increased reliability in
parallel operation- Comprehensive alarm and control facilities for
remote and local monitoring
General• Dimensions (wxhxd):
- 66.8 (6U) x 264 x 220 (excl. handle)/2.63 x 10.4 x 8.66"
- 66.8 (6U) x 264 x 240mm (incl. handle)/2.63 x 10.4 x 9.45"
• Weight: < 2.8kg (< 6.2lbs)
Applicable standards• Safety: EN 60950• EMC:
- EN 61000-6-3 (emission)- EN 61000-6-2 (immunity, industry)- EN 300 386-2 (immunity)
• Environment:- ETSI EN 300 019-2-1- ETS 300 019-2-2- ETS 300 019-2-3
Approvals• CE-marked• UL- Recognized UL 60950
SMPS 1000
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 53/72
53
TwinPack Plus®
Description
The TwinPack Plus® rectifier (TWPP) is a modular, switchmode rectifier.
This rectifier offers a high output (3000 W) rating. Each rectifier accepts
AC input voltage ranging from 176 to 264 VAC, 45 to 65Hz single phase,
and include the following outputs: -48 VDC/50 Amps, +24 VDC/100
Amps, and -24 VDC/100 Amps. Rectifiers with lower output (1500 W)
ratings are also available. These rectifiers will accept AC inputs ranging
from 85 to 264 VAC, and include the following outputs: -48/25, +24/50,
-24 VDC/50 Amps, and +12 VDC/100 Amps. All rectifiers will operate and
produce full output power in an environment of -40°C to +65°C (-40°F to+149°F) with no de-rating of the output capability.
The new remote control (RC) -48 VDC TWPP works with the Flatpack MCU.
The new RC version is still backwards compatible with all SSD type of con-
trol panels.
The TwinPack Plus® is offered in a choice of 584mm (23") wide, or
482mm (19") wide mounting shelves. The 584mm (23") wide shelf will
accept a maximum of four modular plug-in rectifiers; the 482mm (19")
wide shelf will accept a maximum of three. The shelves accept individual
AC feeds for each rectifier.
Typical applications
The rectifier is used in the TwinPack Plus® Power System, typically
powering equipment such as:
• Remote site to central office applications
• Point of Presence (POPs)
• Large Fiber Repeater
• Telephone Switches
• Data Center
• Internet Hubs
• Optical Switches• Co-location
• Cellular base stations
KEY FEATURES
Input
• 176-264 VAC, 45 to 65 Hz, single phase for3000W Units
• 85-264 VAC 45 to 65 Hz, single phase for1500 W Units
• Peak in-rush current at 176 VAC input is lessthan 25 Amps maximum
• Power Factor Correction:- 0.98 Power factor from 50% load to
100% load- 0.995 Power factor at full load and
nominal input
• Total harmonic current distortion:< 5% (50% to 100% load), 3000 W models< 9% (50% to 100% load), 1500 W models
• Meets IEC-1000-3-2 (Limits for harmoniccurrent)
Output
• Output voltage range:- 47 to 56 VDC (float) and 51 to 60 VDC
(equalize) -48 VDC rectifiers- 22 to 28 VDC (float) and 24 to 30 VDC
(equalize) +24 VDC rectifiers- 11 to 14 VDC (float) and 12 to 15 VDC
(equalize) +12 VDC rectifiers
Operation
• Rectifier and shelf comply with the seismicrequirements of Telcordia Technologies
GR-63-CORE Zone 4. Complies with applicableportions of Telcordia Technologies GR947
• Load sharing (current sharing) for paralleloperation
• Current walk-in feature (0 to 90% output in 8seconds)
• Voltage regulation: +/-0.5% from noload to full load and under all line andenvironmental conditions
• All units are less than the values stated below:- 26 dBrn-C-message weighting- 19mv rms between 0 and 1MHz- 5mv rms between 0 and 100kHz- 100 mV peak-to-peak from 0 to 20MHz
• Available Alarms:- Rectifier Failure- AC Failure
- Fan Failure- High Temperature Shutdown- Output High Voltage Shutdown- Open DC Output Breaker
• Operating temp: -40 to +65°C(-40 to +149°F)
• Dimensions (wxhxd):- the four-across shelf/
584 x 267 x 610mm/23 x 10.5 x 24"- the three-across shelf/
610 x 482 x 267mm/24 x 19 x 10.5"• Weight:
- Rectifier/11.3kg (25lbs)- The four-across shelf/22.7kg (49lbs)- The three-across shelf/20.45kg (45lbs)
Approvals
• CE-marked• UL-recognized UL 60950• NEBS Level 3 certified
TwinPack Plus®
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 54/72
54
SMPS 4000
Description
SMPS 4000 is a battery charger and power supply for stand-alone or
parallel operation in the AEON 4000 DC Power systems. Soft switching
technology is used to minimize volume and weight and to obtain fast
voltage regulation. The module accepts wide input voltage variations and
draws sinusoidal current with a soft start power up. When working in
parallel the rectifiers provide active current sharing. The SMPS 4000
represents a high quality power source for critical telecom equipment
where the power demand can go all the way up to 384 kW.
Typical applications
The rectifier is used in the AEON 4000 Power System, typically powering
equipment such as:
• Telephone Switches
• Data Center
• Internet Hubs
• Optical Switches
• Co-location
• Fixed Net Backbone Sites
KEY FEATURES
Input
• Input operating voltage:- single phase 100-300 VAC- 48 VDC/100-185 VAC: Power limitation- 24 VDC/100-150 VAC: Power limitation- 60 VDC/100-185 VAC: Power limitation
• Input current: < 25 Amps• Power Factor: 0.99
Output
• Output power- 48 VDC/4000 W, constant power down
to 48 VDC, maximum current 85 Amps- 60 VDC/4000 W, constant power downto 60 VDC, maximum current 70 Amps
- 24 VDC/3350W, maximum current125 Amps
• Efficiency: > 91%
Operation
• Connections: rear, hot swappable• Output Fuse: 160 Amps• Active Current Sharing Accuracy: +/- 2.5%
of nominal current• Cooling: fan assisted (3 redundant fans)• Communication interface:
- Customized LCD display and keypad- CAN-bus for rectifier and control unit
communication• Available information:
- Input Voltage, Output Voltage- Output Current- Internal Temperature- Power limit- Address- Software version
• Available alarms:- Low Mains- High Mains- High Temperature- Output Fuse- Output High Voltage Shutdown- Internal Failure- Communication Error
General
• Dimensions (wxhxd):
80 x 264 x 450mm/3.2 x 10.4 x 17.7"• Weight: 7.5kg (16.5lbs)
Approvals
• CE-marked• UL-recognized UL 60950• NEBS Level 3 certified
SMPS 4000
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 55/72
55
RM 14400
Description
The RM14400 is a modular, switchmode rectifier for high power applica-
tions. It is the core element used to build up large 24 VDC, 48 VDC and
60 VDC Power systems. The RM 14400 rectifier can be used in closed
cabinets as well as in open 23" racks. The number of RM 14400 rectifiers
used in parallel is almost unlimited. This means that the RM 14400 rectifier
can be used for power plants with output currents of thousands of Amps.
Large power plants with output currents of more than 10 000 Amps can
easily be realized.
Our standard product range offers several power supply systems from
between 750 Amps and 2500 Amps. Other sizes can be customized and
designed upon request. The highly modular system allows great flexibility,
with outstanding performance and powerful remote monitoring capabilities
such as modem, SNMP, TCP/IP solutions.
The basic RM14400 rectifier operates in three phase 400 VAC mains with-
out neutral. The input voltage ranges from 184/320 VAC to 264/457 VAC.
Typical applications
The RM 14400 is used in SVS Power systems, typically poweringequipment such as:
• DSL and SDH Networks
• Telephone Switches
• Large Fibre Repeaters
• Data Centre and Internet Hubs
• Optical Switches
KEY FEATURES
Input
• Input voltage: 230/400 VAC• Frequency: 45 to 65 Hz per phase• Max. Current:28 Arms maximum at 184/320
VAC and 250 ADC output• Power factor: > 0.93 at 90% load or more• Input protection: External fuses, 32 Amps per
phase
Output
• Voltage: 24 VDC/48 VDC/60 VDC(range: 22.2-73.5 VDC)
• Output power: 14.4 kW• Max. current: 250 Amps
General
• Efficiency: > 93%• Rectifier Alarm: Different alarms on LCD,
Mains fault and rectifier fault on volt freecontacts
• Visual indications: LCD display, LED foroperation, LED for fault
• Operating temperature:-10 to + 45°C full power(+14 to +113°F), +60°C with derating(+140°F)
• Storage temperature: -40 to +85°C (-40 to+185°F)
• Cooling: forced cooling• MTBF: > 250 000 hours
• Acoustic Noise: < 55dBA• Dimensions (wxdxh):
483 x 440 x 272mm (6U)/19 x 17.3 x 10.7"• Weight: 43.5kg (100lbs)
Applicable standards
• Safety: EN 60950, class 1• EMC:
- EN 61000-6-3 (emission)(EN 55022, class B)
- EN 61000-6-2 (immunity)• Environment:
- ETSI EN 300 019-2- ETSI EN 300 132-2
• Protection class: IP20, EN 60529
Approvals
• CE-marked
RM 14400
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 56/72
56
Flatpack DC/DCconverter
Description
The Flatpack DC/DC 24/48 is a modular hot plug-in DC/DC converter
prepared for stand-alone use, or for working in parallel as part of a
DC/DC rack system. The converter is specially designed to provide a high
quality and highly reliable DC output voltage.
Switchmode technology with soft switching and high switching frequency
is used to minimize volume and weight, and to obtain fast output voltage
regulation. The module has a soft start power-up. When working in parallel,
the converters provide active current sharing. An internal blocking diodeallows hot plug-in and isolates any faults in the converter output from the
DC-bus.
Several internal protection circuits ensure safe operation, even outside
specified limits for normal operation. A module failure alarm is given if
the module shuts down due to high/low input voltage, high output voltage
(selective), or in case of an internal failure.
Converters connected in parallel will exhibit active load sharing, even
without a Monitoring and Control Unit. Front LEDs show power ON/OFF
and alarm status in addition to a LED bargraph for output currentindication.
KEY FEATURES
Input• Input operating voltage: 19.8-32 VDC• Max. current: 73 Amps at 19.8 VDC input• Protection: Soft start, Surge protection,
Internal fuse, Automatic shutdown for inputvoltages < 19.5 VDC and > 30 VDC
Output• Voltage: 55 VDC• Output power: 1250 W• Output current: 23 Amps• Current Share: ±1 Amp• Static voltage regulation: ±0.5% from 0 to
full load• Dynamic voltage regulation: ±1.0% for
10-90% or 90-10% load variation• Protection:
- Or-ing diode- Non-destructive short circuit operation- Selective high output voltage shutdown
(59.5 VDC)• Efficiency: 90% at full load
General• Converter alarms:
- No output voltage,- Over voltage shutdown- Fan failure- High temperature shutdown- Short circuit/fold back activated
• Converter warnings:- DC input voltage out of range- Single fan failure
- High temperature/derating activated,- Current limit
• Visual indications:- Green LED: ON, no faults- Red LED: No output, converter failure,- Yellow LED bargraph: measuring output
current (0-100%)• Operating temperature:
-40 to +65°C (-40 to +149°F) full power,+65 to +75 °C (+149 to +167°F) derating
• Storage temperature:-40 to +85 °C (-40 to +185°F)
• Cooling: speed controlled fans• MTBF: > 200 000 hours Telecordia issue I,
method III (a)• Acoustic Noise: < 60dBA• Dimensions (wxhxd):
218 x 43 x 240mm/8.58 x 1.69 x 9.45"• Weight: < 3kg (< 6.6lbs)
Applicable standards• Safety: EN 60950, UL 60950• EMC:
- EN 300 386 (telecommunication network)- EN 61000-6-3 (emission, light industry)- EN 61000-6-2 (immunity, industry)
• Environment:- ETSI EN 300 019-2- ETSI EN 300 132-2- Telcordia GR-63-CORE Zone 4- ETSI EN 300 753 (acoustic noise)
Approvals• CE-marked• UL-recognized• NEBS Level 3 certified
Flatpack DC/DC converter
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 57/72
57
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 58/72
58
System monitors
This section outlines our standard monitoring and control units. The products in this range include:
integrated system health monitoring solutions, stand-alone monitoring devices, monitoring of DC power
supplies and distribution and battery support.
Eltek is committed to achieving and maintaining technological excellence of not only our DC Power and
Distribution products, but also our Monitoring and Control solutions. We are able to offer monitoring
products that are easily integrated into an existing telecommunications network infrastructure using
proven, inter-operable, stable and secure technologies and globally accepted communications protocols.
These products provide real-time feedback of critical system parameters and alarm events. This data can
be applied toward statistical analysis of preventive maintenance schedules. Increased DC Power system
reliability is a direct result of this enhanced intelligence.
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 59/72
59
SYSTEM MONITORS
SMALL AND MEDIUM
Flatpack MCU ............................. 60
TWPP/MCU panel ........................ 61
AL 175NT ................................... 62
LARGE
AEON Gold ................................. 63
SOFTWAREWinPower ................................... 64
REMOTE MANAGEMENT
SNMP adapter ............................. 65
WebPower .................................. 66
For small and medium systems we offer the AL 175NT and Flatpack
MCU product lines. These monitoring and control units provide visual
display of system and battery parameters and remote capability with a
serial/modem connection. Using Eltek’s WinPower software, a user can
connect directly to the power plant with a PC for graphical user interface
support. If needed, an SNMP device can be connected to the AL 175NT or
Flatpack MCU alarm modules to provide an Ethernet connection with the
SNMP agent capability.
For large systems we offer the AEON Gold that provides a graphicaldisplay of system and battery parameters and remote capability over a
serial or modem connection. The sophisticated WinPower solution is also
available with the AEON Gold, with extensive battery monitoring and
testing capabilities. An SNMP agent option is also available for the AEON
Gold.
Remote Monitoring provides the industry with reduced Total Cost of
Ownership for DC Power systems, primarily by reducing the need for
technicians to travel to remotely located sites. This reduced TCO can
easily offset the initial investment in Remote Monitoring equipment by
directly reducing operating and maintenance costs associated withtechnical support vehicles and staff. Additional savings are realized by
reduced system downtime.
From low cost embedded digital system monitors to advanced web-
enabled remote monitors, Eltek provides the monitoring and control
solutions for today’s telecommunications DC power needs.
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 60/72
60
Flatpack MCU
Description
The Eltek monitoring and control units have been specifically developed to
provide indication and management for DC standby power systems used
in telecommunications and industrial applications.
The Flatpack MCU is the Monitoring and Control Unit used in Eltek’s
Flatpack Power systems. The unit allows both local and remote monitoring/
control of the DC Power system via front keypads and LCD or an RS-232
serial interface either via serial cable, modems or SNMP agent.
Typical applications
The Flatpack MCU is used in the Flatpack Power systems.
KEY FEATURES
Communications
• RS-232 interface for PC connection, modem orother remote monitoring (SNMP, Web-browser,TCP/IP, etc)
• 6 - 11 user programmable relay outputs fortraditional remote monitoring (6 as standard)
• 5 user programmable inputs for monitoring of other equipment on site
• Modem Callback functionality
Features
• Front panel LCD and keypad for on-site service
(local operation)• Menu driven operation via WinPower Silver• Battery monitoring and testing without site
attendance (history up to 10 previous tests)• Advanced or simple battery test• Temperature Compensated Charge Voltage for
increased battery lifetime• Hot Plug-in MCU unit• Slow current walk-in• Password protected access levels• Alarm/event log with time and date
(up to 255 events)• Site text/ID for identification of each
individual system• Output Voltage Measurement• Load Current Measurement• Battery Current Measurement• Rectifier Current Measurement
• Battery Temperature Measurement• Load/Battery Disconnect• Real Time Clock• Battery Boost Charging• Battery Cable Voltage Drop Compensation
Alarms
• Battery High/ Low Voltage (multi level)• Battery/ load fuse• Symmetry alarm• Rectifier Fail Alarm (critical and non critical)• Temperature Compensated Charging• Low temperature• Rectifier capacity with programmable level• Low temperature with programmable level• Temperature probe• Battery discharge
General
• System voltage: 24 VDC/48 VDC/60 VDC• Dimensions (wxhxd):
123 x 43 x 177mm/4.85 x 1.7 x 6.97"• Weight: 0.7kg (1.55lbs)
Applicable standards
• EMC and Safety: EN 300 386-2 andEN 60950
• ETSI EN 300 019-2 (environmental tests fortransportation, storage and operation)
Approvals
• CE-marked• UL-recognized UL 60950• NEBS Level 3 certified
Flatpack MCU
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 61/72
61
TWPP/MCU panel
Description
The TWPP/MCU is a single rack space (1U) panel that connects TWPP RC
rectifiers to the Flatpack MCU, providing updated features of the Flatpack
rectifier systems to those who prefer the TWPP rectifier power solutions.
The TWPP/MCU device is available as an integrated component in TWPP
rectifier systems.
These units have been specifically developed to provide indication and
management for DC standby power systems used in telecommunications
and industrial applications. TWPP rectifier output voltage is under MCUcontrol and does not require periodic re-adjustment. Individual rectifier
adjustments are no longer necessary.
The MCU controller is hot swappable in a live system without affecting the
system’s ability to deliver charge and load current. Intelligent LVD contactor
drive circuitry prevents spurious operation of the LVD contactor(s) in the
system upon system controller failure or removal. Integrated temperature
compensated charge control and battery symmetry monitoring serve to
maximize battery life and protect against battery damage.
KEY FEATURES
• Three LVD contactor drive outputs, configurablefor battery and/or load disconnect unit
• Hot-swappable Flatpack MCU monitoring unit• LVD memory (Flatpack interface will lock LVD
when MCU is removed)• Front access alarm relay connections
(ten software configurable Form C relays)• Battery symmetry and temperature monitoring,
front access to user connections• Battery EPO/remote disconnect capability via
front access terminals• Local monitoring and control of the DC Power
system via front keypads and LCD• Remote monitoring via the front access RS-232serial interface.
• Direct serial connection, modem or WebPower/SNMP agent is supported.
General
• Dimensions: single 44mm (1.75") mountingheight (1U)
• Mounting brackets available for 482mm (19")and 584mm (23") rack mounting
• Weight: 1kg (2.1lbs)• Operating temperature: -40 to +70°C
(-40 to +158°F)
TWPP/MCU panel
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 62/72
62
AL 175NT
Description
The Eltek range of monitoring and control units has been specifically
developed to provide indication and management for DC Power systems
used in telecommunications and industrial applications. The AL 175NT
plug-in monitoring and control unit is used in Eltek‘s small and medium
range power systems, such as MPSU 200, MPSU 4000, MPSU 5000, MPSU
6000 and PRS 700. The AL 175NT offers a comprehensive range of features
through the utilization of microprocessor technology. The RS-232 serial
interface provides connectivity for remote monitoring, either via serial
cable, modems or SNMP agent.
Remote monitoring options
• With the Windows-based WinPower communication program installed
on a remote computer, the system can be monitored and controlled via
modems. WinPower provides a user-friendly interface (GUI) for remote
control and supervision. The modem callback functionality can be used
to minimize the traffic on the public telephone network.
• From a Network Management System (NMS) via Ethernet. Simple
Network Management Protocol (SNMP) with an external SNMP agent
connected to AL 175NT.
• Six internal failsafe alarm relays provide voltage free contacts that canbe connected to equipment used for traditional alarm monitoring
Typical applications
The AL 175NT is used in systems incorporating the SMPS 200 and SMPS
1000 rectifiers.
KEY FEATURES
Communications
• RS-232 interface for PC connection, modem orother remote monitoring (SNMP, Web-browser,TCP/IP, etc)
• 6 user programmable relay outputs fortraditional remote monitoring
• Modem Callback functionality
Features
• Front panel LCD and keypad for on-site service(local operation)
• Menu driven operation via WinPower Silver
• Battery monitoring and testing without siteattendance• Temperature compensated charging for
increased battery lifetime.• Hot plug-in• Password protected access levels• Alarm/event log with time and date
(up to 255 events)• Site text/ID for identification of each
individual system• Controls LVD units based on voltage or internal
timer• High/Low Battery Voltage Alarm• Battery boost charging• Load/Battery Disconnect Alarm
Alarms
• Battery High/Low Voltage
• Battery/Load Fuse• High Battery Temperature• Symmetry Failure (option)• Battery Test failure• Mains Failure• Rectifier Failure
General
• System voltage: 24 VDC/48 VDC/60 VDC• Dimensions (wxhxd):
70.7 x 133 (3U) x 169mm/2.8 x 5.25 x 6.7"• Weight: approx. 1kg (2.2lbs)• MTBF: 203 658 hours (Bellcore I, group III (a)
+40°C (104°F))
Approvals
• CE-marked
• UL-recognized UL 60950
AL 175NT
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 63/72
63
AEON Gold Monitoringand Control Unit
Description
AEON Gold is a control and monitoring unit for the AEON 4000 high
power DC system. The unit offers advanced control functions, which
include both remote and local surveillance. Digital communication buses
are available for communication with rectifiers, PCs and other communi-
cation devices. A front panel with keypad and graphical display provides
local control and monitoring facilities while connection to PC through
RS-232 outputs enables the use of WinPower Gold.
The RS-232 serial interface provides connectivity for remote monitoring,either via serial cable, modems or SNMP agent. The unit incorporates
highly advanced functionality, which makes it the preferred choice in
applications where high reliability and demanding control functions are
required.
Typical applications
The AEON Gold unit is used in the AEON 4000 and High Current AEON
Systems.
KEY FEATURES
Communications
• Rectifier interface: CAN-bus• PC communication: RS-232 pComm protocol• PC user interface: WinPower Gold• Remote interface via RS-232: SNMP, TCP/IP,
modem, etc
Operation
• Alarm logging in non-volatile memory• Language selection• Software upgrade through PC and serial port• Ten configurable alarm outputs
• Eight digital inputs• Flexible alarm system setup• Temperature Compensated Charging• Boost Charging• Battery Test with capacity calculation• Individual Rectifier Control
General
• AC input voltage: 100-300 VAC• DC supply voltage: 20-60 VDC• Maximum alarm relay current: 8 Amps• Dimensions (wxhxd):
- Display unit/490 x 89 x 33mm/19.3 x 3.5 x 1.3"
- Controller unit/557 x 128 x 103mm/21.9 x 5.04 x 4.1"
• Weight: 2.4kg (5.3lbs)
Applicable standards
• CE-marked• UL-recognized• NEBS Level 3 certified
AEON Gold display unit
AEON Gold controller unit
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 64/72
64
WinPower
Description
WinPower is the computer software developed by Eltek for communication
with our DC Power systems. WinPower is available in two versions:
WinPower Gold for applications with AEON Gold systems, and WinPower
Silver for applications with AL 175NT and Flatpack MCU control and
monitoring units.
Typical applications
WinPower Silver covers systems having small to medium power require-
ments to applications where the power requirement is up to approximately60 kW. WinPower Silver can be used with Eltek products like MPSU 200,
MPSU 4000, MPSU 5000, MPSU 6000, PRS 700 and the Flatpack systems
range.
WinPower Gold covers the high power requirements and goes along with
the AEON 4000 Power Systems. Sites with several hundreds of kW can be
monitored and controlled using WinPower Gold.
KEY FEATURES
WinPower represents an easy way of understadingand setting up the configuration of the powersystem.
Windows based menus and dialogues give theoperator an excellent tool for controlling thepower system.
WinPower is divided into three access levels wherethe lowest level does not require a password.
At user level all system information is available
but nothing can be changed.
The next level, service level, requires a password.Here it is possible to change the system settingsand turn the system on and off.
The third level, factory menu, is normallyprogrammed during factory test and contains basicparameters like system voltage and contactorconfiguration.
WinPower can be used on a remote computer withe.g. modem connection to the site. In addition toremote access to all functions in the system it isalso possible to get automatic callback on alarms.
In system deliveries where WinPower Silver orWinPower Gold is required the software will be
included on CDs. The CD will after being installedinto the CD-ROM drive, auto start the installationprogram.
• PC requirements: runs on Win95, Win98,Windows NT, Windows 2000 and Windows XP
• Communication link: pComm protocol throughRS-232 link
• Communication speed: 9600 baud (selectable)special pin out on communication cablerequired
WinPower
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 65/72
65
SNMP Adapter
Description
Eltek has developed SNMP (Simple Network Management Protocol) adapters
to interface our most common control and monitoring units to a LAN or to
the Internet. Two versions are available, one for the AL 175NT and
Flatpack MCU and one for the AEON Gold monitoring and control unit.
The SNMP adapters translate the pComm protocol, transferred from the
control units through RS-232, to SNMP. The SNMP is available on the
Ethernet port of the adapter.
Typical applicationsSNMP is widely used within the computer and telecom business for remote
monitoring and control of equipment. For DC Power systems it is becoming
more and more common and represents an easy way of connecting the
DC Power system to the Internet for remote monitoring and control.
SNMP adapters are available throughout Eltek’s product range and can be
installed together with DC Power systems like MPSU 200, MPSU 4000,
5000, 6000, PRS 700, Flatpack and AEON 4000 systems.
KEY FEATURES
The SNMP adapter offers an interface to aNetwork Management System (NMS) viaEthernet connection.
Common NMSs like HP OpenView, SNMPc andMGSoft can communicate with the adapters aslong as they have the MIB information.
The MIB is a file that contains information aboutthe parameters available through SNMP and isdelivered along with the adapter.
There are three types of messages transferredthrough SNMP.• "Get" messages are sent by the NMS to get
status messages from the DC Power system.• "Set" messages are sent by the NMS to
change the system settings or operationalstatus.
• "Traps" are initiated by the DC Power systemwhen alarms occur and are sent directly tothe NMS.
Each site is identified by an IP address. TheIP address needs to be allocated and entered intothe SNMP adapter during installation. To maintainsecurity the SNMP adapter can be configured torespond to only a few IP addresses. By usingSNMP communication nationwide or even world-wide, sites with Eltek power systems can be easily
monitored through one control center.
SNMP adapter
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 66/72
66
WebPower
Description
The Eltek WebPower is the perfect interface between the Eltek DC Power
system and your network. WebPower includes the highly reliable SNMP
traps for alarm messages combined with easy access over HTML (using
any web-browser). E-mail and SMS functionality is also included making
the Eltek WebPower suitable for most Network Management Systems.
Typical applications
• Remote or limited access telecommunications sites
• Locations requiring connectivity to a centralized SNMP NetworkManagement Station
• Mission-critical power systems requiring real time data access from
diverse locations
KEY FEATURES
• Provides a simple yet comprehensive
Graphical User Interface (GUI) via anembedded web server. The interface is derivedfrom the WebPower PC interface, so WinPowerusers will find WebPower easy and intuitive touse.
• Remote Access reduces the Total Cost of
Ownership of DC Power systems - primarilyby reducing the need for technicians to travelto remotely located sites. All sites can bemonitored from a single location.
• Real-time Data Feedback of criticalsystem parameters and alarm events canbe achieved from virtually anywhere on theplanet.
• Remote Control of the DC Power systemenables power system administrators toperform advanced troubleshooting methods -and avoid disastrous system downtime.
• Simple Network Management Protocol
(SNMP) support. SNMP is a widespreadindustry standard for the management of networked devices.
• Platform independence – the monitoringPC can be Windows, Macintosh, UNIX, Linux –
any modern operating system and hardwareplatform that supports a standard web-browsersupporting dynamic page content. This includesmany handheld devices such as PDAs andtablet PCs.
• Freedom from software installation and
version control issues at the PC.No software other than a web-browser needsto be installed on the user's computer. All datais exchanged using standard HTTP Internetprotocol, and the WebPower interface is loadedautomatically by the web-browser as required.
• Remote upgrades of the WebPower firmwareare possible over the network connection,without any special hardware. Updating of all
sites is possible from a single location.
• Multiple concurrent browser
connections allow for cooperative trouble-shooting efforts and user training sessions.
• Access security is provided to restrictunauthorized attempts to alter systemsettings. Group level access control isprovided, with three access levels defined.
WebPower
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 67/72
67
OTHER PRODUCTS AND SERVICES
Outdoor cabinet solutions ............. 68Remote powering ofbroadband/DSL ........................... 69Extensive service offer ................. 70
Other products and services
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 68/72
KEY FEATURES
• Dimensions large cabinet (example) (wxdxh):- External/
770 x 805 x 1940mm/30.3 x 32 x 76.4"incl. roof 152mm (6") and plinth 30mm (1.2")
- Internal/635 x 730 x 1650mm (37U)/25 x 28.7 x 65"
• Dimensions small cabinet (example) (wxdxh):- External/
770 x 800 x 1300mm/30.3 x 31.5 x 51.2"incl. roof 152mm (6") and plinth 20mm (0.8")
- Internal/635 x 730 x 1075mm (24U)/25 x 28.7 x 42.3"
• Weight: excl. air conditioning unit- Large cabinet/200kg (441lbs)- Small cabinet/150kg (330.7lbs)
68
Outdoor cabinetsolutions
Description
Outdoor cabinets for site support UMTS and GSM base stations are designed
for different climate conditions, being equipped with custom designed
heaters and thermal management suitable for a specified temperature range
and humidity. Outdoor cabinets are suitable for 19" mounting of Flatpack DC
Power systems up to 12 kW and provide space for microwave radio units
and batteries. Detailed design of size and cable management are tailored to
customer needs.
Typical applications• Site support cabinets for UMTS and GSM Base Stations
Outdoor cabinet solution withFlatpack MPSU 9000
Outdoor cabinet solution(an example)
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 69/72
69
Remote poweringof broadband/ DSL
Description
Remote powering is a concept for distributing DC power over existing
twisted pairs. The concept is typically for use in broadband applications,
where telecom equipment is located closer to the end user and requires
power (DSLAM). What makes Remote Powering attractive is the independ-
ence from the local power utilities and the centralized back-up system
(batteries).
The Flatpack Remote Power Systems are designed to provide ±190 VDC
or ±130 VDC from a 48 VDC source for remote powering of telecomequipment. The power system consists of DC/DC converters, VA limiters
providing a safe distribution of the power over existing twisted pairs, and
a remote end DC/DC converter converting the high DC voltage down to 48
VDC for powering the DSLAM equipment. The Flatpack VA limiter unit is
designed to protect the Remote Feeding Telecommunications Circuits
(RFT) from overvoltage, overcurrent and leakage current to ground, and
the design is based on the IEC 60950-21, IEC 60950 and GR-1089-CORE
safety standards.
The VA limiter is designed for ±190 VDC and ±130 VDC system voltage,
RFT-V and RFT-C circuits. The module has 12 outputs of up to 100 Weach (RFT-V). The central office systems vary from 2U/ 24 outputs to
complete cabinets with up to 432 VA limiter outputs. The remote end
converter consist of parallel DC/DC converters specifically designed to
work from a limited power source (VA limiter) fed over a high impedance
line and incorporates high energy surge protection. The modules can be
paralleled to meet the power requirement
at the remote end.
Typical applications
Operators can introduce personalized
multimedia services such as• Video On Demand
• Interactive Gaming
• Video Conferencing
• Real-time Broadcast TV
• Internet
KEY FEATURES
Systems
• Mini RPS- Two DC/DC converters 48/130 VDC or
48/190 VDC- Two VA-limiters with a total of 24 output
channels- Dimensions (wxhxd):
482.6 x 48.9 (2U) x 300mm/19 x 1.96 x 11.8"- Weight: 14kg (30.9lbs) incl. converters and
VA limiters• Base COPS
- 36 DC/DC converters 48/130 VDC or
48/190 VDC- 36 VA-limiters with a total of 432 outputchannels
- Dimensions (wxdxh):600 x 600 x 2000mm/24 x 24 x 79"
- Weight: 300 kg (661.4lbs) excl. convertersand VA limiters
Modules
• DC/DC converter- Input: 48 VDC (40-60 VDC)- Output:
130 VDC: (125-139 VDC)/6.6 Amps90 VDC: (160-199 VDC)/6.6 Amps
- Dimensions (wxhxd):218 x 43 x 240mm/8.58 x 1.69 x 9.45"
- Weight: 3kg (6.6lbs)• VA Limiter
- Input: ±130 VDC or ±190 VDC- Output:
12 channels of ±130 VDC or ±190 VDCRFT-V: max. 100 WRFT-C: max. 50mA
- Dimensions (wxhxd):214 x 41.5 x 243mm/8.4 x 1.6 x 9.6"
- Weight: 1.5kg (3.3lbs)
Remote End Converter
• Input: 100-400 VDC, 2 to 10 channels permodule
• Output: 54 VDC (48-55 VDC)/1.5 Amp perchannel
Approvals
• EN 60950 (pending)
• EN 60950-21 (pending)• UL 60950 (pending)• Telcordia NEBS GR-63-CORE (pending)• Telcordia NEBS GR-1089-CORE (pending)
Mini RPS
Base COPS
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 70/72
7070
Extensive serviceoffer
Installation and Commissioning
The installation and full test of the equipment on site after delivery is vital
to assure future trouble-free operation. Eltek engineers and our specialist
partners are the most qualified people to perform these types of services.
Preventive Maintenance
A regular check on your equipment often prevents expensive repairs by
identifying any default or weakness as early as possible. A full report
follows each visit. This gives you an update on the condition of your
equipment and helps you plan upgrading, expansion or renewal. Ourstandard preventive maintenance service includes full test, visual check,
real and simulated alarm checks, alarm history check and a full report
with recommendations.
Battery maintenance
In addition to system maintenance, Eltek is able to perform battery
maintenance. This includes supplying all of the measuring tools and load
equipment necessary to operate a controlled discharge of the battery
bank and test each individual cell. All measurements are recorded and
listed in a report presented at the end of the operation.
24 hours emergency service
For total peace of mind, our 24 hour emergency service provides you with
the assistance of an experienced engineer at all times over the phone and
on-site visits within pre-defined times according to location. It is also possible,
depending on system configuration, to establish a modem connection between
the power systems on site and Eltek, ensuring direct access to control the
system from a remote location.
On site service
On site service is available both as part of a service contract and on an
"ad hoc" basis.
Product repairs
All product repairs are based on fixed prices and are guaranteed for one year.
Training
A comprehensive range of training courses is available and can be
customized to meet specific customer needs.
Our dedicated team of engineersand officially certified partners can
perform a wide range of services on
our products: 24 hours a day, 7 days
a week.
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 71/72
71
Abbreviations
3G – Third generation mobile cellular networks
AC – Alternating Current
AM – Product configured for requirements of
North and South America
Ah – Abbreviation for ampere-hours
Amp – Abbreviation for ampere
Arms – Abbreviation for ampere root mean square
AWG – American Wire Gauge
BDU – Battery Distribution Unit
CDMA – Code Division Multiple Access
CE – European mark of conformityCOPS – Central Office Power Supply
DC – Direct current
DCD – DC Distribution
DLC – Digital Loop Carrier
DSL – Digital Subscriber Line
DSLAM – Digital Subscriber Line Access Multiplexer
EMC – Electromagnetic Compatibility
EN – European Norm
ETSI – European Telecommunications
Standards Institute
EPO – Emergency Power Off
FMA – Flatpack Monitoring Alarm moduleForm C – A relay contact set description consisting
of a make, break and a common connection
GSM – Global Standard for Mobile Communications
GUI – Graphical User Interface
HTML – Hyper Text Markup Language
HTTP – Hyper Text Transfer Protocol
I/O – Input/ Output
IEC – International Electrotechical Commission
IP – Internet Protocol
ISDN – Integrated Services Digital Network
LAN – Local Area Network
LCD – Liquid Crystal Display
LED – Light Emission Diode
LVBD – Low Voltage Battery Disconnect
LVD – Low Voltage Disconnect
LVLD – Low Voltage Load Disconnect
MCB – Miniature Circuit Breaker
MCCB – Molded Case Circuit Breaker
MCU – Monitoring and Control Unit
MIB – Management Information Base
MPSU – Modular Power Supply Unit
ms – Abbreviation for millisecond
MTBF – Mean Time Between Failure
NEBS – Network Equipment-Building Systems
NMS – Network Management System
PABX – Private Automatic Branch Exchange
PC – Personal Computer
pComm – Binary master-slave communication
protocol
PDA – Personal Digital Assistant
PDU – Power Distribution UnitPIDU – Plug-in Distribution Units
POPs – Points of Presence
PR – Power Rack
PRS – Power Rack System
PRSB – Power Rack System with Battery
RC – Remote Control
RFT-V/-C – Remote Feeding Telecommunications
Circuits
RM – Rectifier Module
RPS – Remote Powering System
SDH – Synchronous Digital Hierarchy
SMPS – Switch Mode Power SupplySMS – Short Message Service
SNMP – Simple Network Management Protocol
SSD – System Status Display
TCO – Total Cost of Ownership
TCP/IP – Transmission Control protocol/
Internet Protocol
TDMA – Time Division Multiple Access
TETRA – Terrestrial Trunked Radio
THD – Total Harmonic Distortion
TWPP – TwinPack Plus® power system
TWPP/MCU – Monitoring and Control Unit in
TwinPack Plus® power system
U – Height unit (44.45mm (1.75"))
UL – Underwriters Laboratories Incorporated
UMTS – Universal Mobile Telecommunications
System
VA – Abbreviation for volt-ampere
VAC – Abbreviation for alternating current
VDC – Abbreviation for direct current
W – Abbreviation for watt
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 72/72
AMERICAS
Eltek Energy, LLC115 Erick StreetCrystal Lake, IL 60014-4533
USATel: +1 8154599100Fax: +1 8154599118
PCP International de MexicoAv. Gustavo Baz No. 401Col. Hacienda del ChristoNaucalpan de Juarez Edo.C.P. 53138, MexicoTel: +52 5552206455
ASIA/PACIFIC
Eltek Energy Pte Ltd.192 Pandan Loop #06-02/04Pantech Industrial ComplexSingapore 128381
Tel: +65 6 7732326Fax: +65 6 7753602
Eltek Service (Thailand) Co. Ltd.654/3 Moo 8, Soi Ramintra 32Bangkhen, Bangkok 10230 THThailandTel: +662 943 6905Fax: +662 943 6647
Eltek Energy Pte LtdRepresentative OfficeRoom 302Orient Square BuildingEmerald AvenueOrtigas Center
Pasig City 1605PhilippinesTel: +632 910 6355Fax: +632 910 6358
Eltek SGS Pvt Ltd362, Pace City - IISector - 37Gurgaon - Haryana
India 122 001Tel: +91 1242210018/19+91 1242370852
Fax: +91 1242210017
Eltek Pacific Pty LtdUnit 1, 22 Narabang WayBelrose, NSW 2085AustraliaTel: +61 294500550Fax: +61 294501661
CHINA
Eltek Energy LtdRoom 812, Eight Commercial Tower8 Sun Yip Street, Chai Wan
Hong KongTel: +852 28982689Fax: +852 28983189
Eltek Energy Technology (Dongguan) LtdGuancheng Science and Technology ParkShilong RoadGuancheng Road’s SectionDongguan CityGuangdong Province 523119PR ChinaTel: +867 692651108Fax: +867 692296797
EUROPEEltek Energy ASPO Box 2340 Strømsø3003 Drammen
Eltek Energy (UK) LtdEltek House, Maxted RoadHemel HempsteadHertfordshire HP2 7DX
United KingdomTel: +44 1442219355Fax: +44 1442245894
Eltek – SFEE SA.Z.I. de Bastillac-Nord65000 TarbesFranceTel: +33 562340930Fax: +33 562345869
Eltek Polska Sp. Z o.o.ul. Gorlicka 271-042 SzczecinPolandTel: +48 914869960Fax: +48 914834986
Voigt & Haeffner GmbHFerdinand-Porsche-Str. 4560386 Frankfurt a. M.GermanyTel: +49 69 42002-0Fax: +49 69 42002-389
Eltek Energy ABSjöängsvägen 9192 72 SollentunaSwedenTel: +46 86266420Fax: +46 86266430
OOO Eltek Russia
2nd Sovyetskaya House 7Office 108193036 St. PetersburgRussia
HEAD OFFICE
Eltek Energy AS
PO Box 2340 Strømsø, 3003 DrammenGråterudveien 8, 3036 DrammenNorwayTel: +47 32203200Fax: +47 32203210www.eltekenergy.com