F84G - Excelon® Plus Modular System General purpose filter 11/17 en 8.200.150.01 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2017 - 9213a) © 2015 Norgren Ltd Technical features Technical data F84G - standard models Symbol Port size Drain Filter element Bowl Weight Model (µm) (kg) G3/8 Auto 40 Guarded polycarbonate 0,38 F84G-3GN-AP3 G1/2 Auto 40 Guarded polycarbonate 0,38 F84G-4GN-AP3 G3/4 Auto 40 Guarded polycarbonate 0,38 F84G-6GN-AP3 G3/8 Auto 40 Metal with level indicator 0,52 F84G-3GN-AD3 G1/2 Auto 40 Metal with level indicator 0,52 F84G-4GN-AD3 G3/4 Auto 40 Metal with level indicator 0,52 F84G-6GN-AD3 G3/8 Manual 40 Guarded polycarbonate 0,38 F84G-3GN-QP3 G1/2 Manual 40 Guarded polycarbonate 0,38 F84G-4GN-QP3 G3/4 Manual 40 Guarded polycarbonate 0,38 F84G-6GN-QP3 G3/8 Manual 40 Metal with level indicator 0,52 F84G-3GN-QD3 G1/2 Manual 40 Metal with level indicator 0,52 F84G-4GN-QD3 G3/4 Manual 40 Metal with level indicator 0,52 F84G-6GN-QD3 > Port size: 3/8” ... 3/4” (ISO G/PTF) > Excelon ® Plus design allows in-line installation or modular installation with other Excelon ® Plus products > 5 or 40 micron particle and high efficiency water removal (> 98%) > Double safety lock bowl > Metal bowl with prismatic liquid level indicator lens > Light weight polycarbonate bowl > Air purity classes in accordance to ISO8573-1: particles class 6 & 7 and liquid water class 8 Medium: Compressed air only Maximum supply pressure: Polycarbonate bowl: 10 bar (145 psi) Metal bowl: 20 bar (290 psi) Filter element: 5 μm & 40 μm Port size: G3/8, G1/2, G3/4, 3/8 PTF, 1/2 PTF, 3/4 PTF Flow: 78 dm 3 /s at port size: 1/2”, operating pressure 6,3 bar (91 psi) and a Δp: 0,5 bar (7,25 psi) drop from set. Filter element: 40 μm Drain: Manual or automatic Automatic drain operating conditions (float operated): Bowl pressure required to close drain: > 0,35 bar (5 psi) Bowl pressure required to open drain: ≤ 0,2 bar (2,9 psi) Minimum air flow required to close drain: 1 dm 3 /s (2 scfm) Ambient/Media temperature: Polycarbonate bowl: -10 ... +60ºC (14 ... +140ºF) Metal bowl: -20 ... +65ºC (-4 ... +149ºF) Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F). Materials: Body: Die cast aluminium Body covers: ABS Bowl: Transparent PC with PP guard or die cast aluminium Liquid level indicator lens (metal bowl): PA Filter element: sintered PP Bowl ‘o’- ring: Chloroprene Elastomers: NBR

Transcript of > Port size: 3/8” 3/4” > Metal bowl with (ISO G/PTF...

Page 1: > Port size: 3/8” 3/4” > Metal bowl with (ISO G/PTF ...cdn.norgren.com/pdf/en_8_200_150_F84G.pdf · at port size: 1/2”, operating pressure 6,3 bar (91 psi) and a Δp: 0,5 bar

F84G - Excelon® Plus Modular System General purpose filter

11/17en 8.200.150.01

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2017 - 9213a) © 2015 Norgren Ltd

Technical features

Technical data F84G - standard modelsSymbol Port size Drain Filter element Bowl Weight Model

(µm) (kg)

G3/8 Auto 40 Guarded polycarbonate 0,38 F84G-3GN-AP3

G1/2 Auto 40 Guarded polycarbonate 0,38 F84G-4GN-AP3

G3/4 Auto 40 Guarded polycarbonate 0,38 F84G-6GN-AP3

G3/8 Auto 40 Metal with level indicator 0,52 F84G-3GN-AD3

G1/2 Auto 40 Metal with level indicator 0,52 F84G-4GN-AD3

G3/4 Auto 40 Metal with level indicator 0,52 F84G-6GN-AD3

G3/8 Manual 40 Guarded polycarbonate 0,38 F84G-3GN-QP3

G1/2 Manual 40 Guarded polycarbonate 0,38 F84G-4GN-QP3

G3/4 Manual 40 Guarded polycarbonate 0,38 F84G-6GN-QP3

G3/8 Manual 40 Metal with level indicator 0,52 F84G-3GN-QD3

G1/2 Manual 40 Metal with level indicator 0,52 F84G-4GN-QD3

G3/4 Manual 40 Metal with level indicator 0,52 F84G-6GN-QD3

> Port size: 3/8” ... 3/4” (ISO G/PTF)

> Excelon® Plus design allows in-line installation or modular installation with other Excelon® Plus products

> 5 or 40 micron particle and high efficiency water removal (> 98%)

> Double safety lock bowl

> Metal bowl with prismatic liquid level indicator lens

> Light weight polycarbonate bowl

> Air purity classes in accordance to ISO8573-1: particles class 6 & 7 and liquid water class 8

Medium:Compressed air onlyMaximum supply pressure:Polycarbonate bowl: 10 bar (145 psi)Metal bowl: 20 bar (290 psi)Filter element:5 μm & 40 μmPort size:G3/8, G1/2, G3/4, 3/8 PTF, 1/2 PTF, 3/4 PTF

Flow:78 dm3/s at port size: 1/2”, operating pressure 6,3 bar (91 psi) and a Δp: 0,5 bar (7,25 psi) drop from set. Filter element: 40 μmDrain:Manual or automatic Automatic drain operatingconditions (float operated):Bowl pressure required to close drain: > 0,35 bar (5 psi) Bowl pressure required to open drain: ≤ 0,2 bar (2,9 psi) Minimum air flow required to close drain: 1 dm3/s (2 scfm)

Ambient/Media temperature:Polycarbonate bowl: -10 ... +60ºC (14 ... +140ºF)Metal bowl:-20 ... +65ºC (-4 ... +149ºF) Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F).

Materials:Body: Die cast aluminiumBody covers: ABSBowl: Transparent PC with PP guard or die cast aluminiumLiquid level indicator lens (metal bowl): PAFilter element: sintered PPBowl ‘o’- ring: ChloropreneElastomers: NBR

Page 2: > Port size: 3/8” 3/4” > Metal bowl with (ISO G/PTF ...cdn.norgren.com/pdf/en_8_200_150_F84G.pdf · at port size: 1/2”, operating pressure 6,3 bar (91 psi) and a Δp: 0,5 bar

F84G-˙˙N-˙˙˙

0,0

0,1

0,2

0,3

0,4

0,5

0,6

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95

Pre

ssur

e dr

op

Air flow (dm³/s)

F84G - 40 Microns - 10 bar

2.5 4.0

8.0

6.3

10

1.6

0,0

0,1

0,2

0,3

0,4

0,5

0,6

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95

Pre

ssur

e dr

op

Air flow (dm³/s)

F84G - 5 Microns - 10 bar

2.5 4.0

8.0

6.3

10

1.6

F84G - Excelon® Plus Modular System General purpose filter

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2017 - 9213a) © 2015 Norgren Ltden 8.200.150.02

11/17

Option selectorPort size Substitute

3/8” 3

1/2” 4

3/4” 6

Thread form Substitute

PTF A

ISO G parallel (standard) G

Drain Substitute

Manual (standard) Q

Auto drain (standard) A

Element Substitute

5 µm 1

40 µm (standard) 3

Bowl Substitute

Transparent with guard (standard) P

Metal with liquid indicator (optional)

D

Flow characteristics

Pre

ssur

e d

rop

Δp

(bar

)

Air flow (dm3/s)

Element 40 µm Port size: 1/2”

Pre

ssur

e d

rop

Δp

(bar

)

Air flow (dm3/s)

Element 5 µm Port size: 1/2”

Inlet pressure

Inlet pressure

Page 3: > Port size: 3/8” 3/4” > Metal bowl with (ISO G/PTF ...cdn.norgren.com/pdf/en_8_200_150_F84G.pdf · at port size: 1/2”, operating pressure 6,3 bar (91 psi) and a Δp: 0,5 bar

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2017 - 9213a) © 2015 Norgren Ltd

F84G - Excelon® Plus Modular System General purpose filter

en 8.200.150.0311/17

Full flow porting block 3/4 PTF

Full flow porting block G3/4

Pressure switch interface block (18D pressure switch)

Pneumatic pressure switch 18D (0,5 ... 8 bar) *1)

Digital pressure switch 51D (-1 ... 10 bar) *2)

Page 6 Page 6 Page 7 Page 7 Page 7

840028-50KIT 840028-53KIT 0337717000000000 0881300 0860810

*1) Flanged version. For other pressure ranges, please see data sheet 5.11.001 *2) For other pressure ranges, please see data sheet 5.11.385

Port Adaptors 3/8 PTF

Port Adaptors 1/2 PTF

Port Adaptors 3/4 PTF

Port Adaptors G3/8

Port Adaptors G1/2

Port Adaptors G3/4

Page 7 Page 7 Page 7 Page 7 Page 7 Page 7

840015-02KIT 840015-03KIT 840015-04KIT 840015-10KIT 840015-11KIT 840015-12KIT

AccessoriesWall mounting bracket Quikclamp® Quikclamp®

with bracket assembledPressure sensing block 1/4 PTF

Pressure sensing block G1/4

Page 6 Page 6 Page 6 Page 6 Page 6

840024-50KIT 840014-51KIT 840014-52KIT 840016-50Kit 840016-51KIT

Page 4: > Port size: 3/8” 3/4” > Metal bowl with (ISO G/PTF ...cdn.norgren.com/pdf/en_8_200_150_F84G.pdf · at port size: 1/2”, operating pressure 6,3 bar (91 psi) and a Δp: 0,5 bar

F84G - Excelon® Plus Modular System General purpose filter

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2017 - 9213a) © 2015 Norgren Ltden 8.200.150.04

11/17

Maintenance/ServiceFilter cartridge5 micron

Filter cartridge 40 micron

Auto drain kit with metal Nut - Imperial

Auto drain kit with metal Nut - Metric

840038-50KIT 840038-51KIT 6000-61KIT 6000-60KIT

Spare partsFilter Bowl (Guarded Poly bowl with auto drain 6 mm PIF)

Filter Bowl (Guarded Poly bowl with manual drain)

Filter Bowl (Metal with S/Glass & auto drain, 6 mm PIF)

Filter Bowl (Metal with S/Glass & manual drain)

840025-51KIT 840025-50KIT 840003-51KIT 840003-50KIT

Filter Bowl (Guarded Poly bowl with auto drain, 1/4 PIF)

Filter Bowl (Metal with S/Glass & auto drain, 1/4 PIF)

840025-53KIT 840003-56KIT

Page 5: > Port size: 3/8” 3/4” > Metal bowl with (ISO G/PTF ...cdn.norgren.com/pdf/en_8_200_150_F84G.pdf · at port size: 1/2”, operating pressure 6,3 bar (91 psi) and a Δp: 0,5 bar

70

7320

5#

25

36 36

208

176

29

3

1

2

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2017 - 9213a) © 2015 Norgren Ltd

F84G - Excelon® Plus Modular System General purpose filter

en 8.200.150.0511/17

Dimensions Dimensions in mm Projection/Third angle

Automatic Drain1/4 Turn Manual Drain

# Minimum clearance for bowl removal1 Main ports 3/8”, 1/2” or 3/4”

(ISO G/PTF)2 Transparent bowl with guard3 Metal bowl with liquid level indicator

lens

Page 6: > Port size: 3/8” 3/4” > Metal bowl with (ISO G/PTF ...cdn.norgren.com/pdf/en_8_200_150_F84G.pdf · at port size: 1/2”, operating pressure 6,3 bar (91 psi) and a Δp: 0,5 bar

71

58

8.9 15

47

15

58

36

5766

4

18

29

31

56

11.5

60

4749

76

119

54

14

4

5

7

51

54.3

51

21

33

45

80 51

5746

68

F84G - Excelon® Plus Modular System General purpose filter

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2017 - 9213a) © 2015 Norgren Ltden 8.200.150.06

11/17

Dimensions in mm Projection/Third angle

Accessories

Mounting bracket

Quikclamp®Quikclamp® with wall bracket

Pressure sensing block Full flow porting block

Page 7: > Port size: 3/8” 3/4” > Metal bowl with (ISO G/PTF ...cdn.norgren.com/pdf/en_8_200_150_F84G.pdf · at port size: 1/2”, operating pressure 6,3 bar (91 psi) and a Δp: 0,5 bar

44

32

40

40G1/2

5

30

30

45

18 A

/C

27.5

72

35

44

32

40

57

G1/2

40

38.5

38.5

18

80 51

5746

68

~300

31

1

3

56

4

7

31

G1/

8

36,5

~30

2

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2017 - 9213a) © 2015 Norgren Ltd

F84G - Excelon® Plus Modular System General purpose filter

en 8.200.150.0711/17

18D Pressure switchPorting block for 18D pressure switch

18D Porting block and 18D assembled

Pipe adaptor

51D Pressure switch - digital

Dimensions in mm Projection/Third angle

1 Switch OUT 1, green LED 2 Switch OUT 2, red LED 3 Dustproof protector 4 Connector M12 x 1 5 Inlet port 6 Alternative inlet port G1/8 plugged 7 Thread for mounting screw

Page 8: > Port size: 3/8” 3/4” > Metal bowl with (ISO G/PTF ...cdn.norgren.com/pdf/en_8_200_150_F84G.pdf · at port size: 1/2”, operating pressure 6,3 bar (91 psi) and a Δp: 0,5 bar

F84G - Excelon® Plus Modular System General purpose filter

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2017 - 9213a) © 2015 Norgren Ltden 8.200.150.08

11/17

Warning

These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under »Technical features/data«. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems or other applications not within published specifications, consult IMI Precision Engineering, Norgren Ltd.

Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products.

EN - Englisch