+ - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a...
-
Upload
russell-parrish -
Category
Documents
-
view
214 -
download
0
Transcript of + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a...
![Page 1: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/1.jpg)
+ - + -+ - ++ -+
Plasma Air Presentation
![Page 2: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/2.jpg)
+ - + -+ - ++ -+
2
Agenda
• The positive effects of a higher ion count• How Plasma Air technology works• Product performance – laboratory testing• Products• Selection guides• Product Applications • ASHRAE’s IAQ Procedure (and the IMC Exception)• Cost analysis of a typical project• How to design an IAQ Procedure project• Validation study• Worldwide references• Summary
![Page 3: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/3.jpg)
+ - + -+ - ++ -+
3
The positive effects of a higher ion count
Activated oxygen ions:• Charge particles causing them to
stick together. Larger, heavier particles then fall to the floor or get caught by the system filter.
• Inhibit the growth of mold and bacteria by penetrating the cell’s split zone
• Oxidize odorous gases• Break down VOCs* and chemicals
into CO2 and H2O• Balance static electricity• Neutralize the symptoms of Sick
Building Syndrome
*Volatile Organic Compounds
![Page 4: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/4.jpg)
+ - + -+ - ++ -+
4
The positive effects of a higher ion countSize Distribution of Typical Atmospheric
Contaminants*
Range of Average Number Percent by Percent
Particle Particle of Particle by
Size (Micron) Size (Micron) Particles Count Weight
10 - 30 20 1,000 0.005 28
5 - 10 7.5 35,000 0.175 53
3 - 5 4 50,000 0.25 11
1 - 3 2 214,000 1.07 5
0 - 1 0.5 19,632,000 98.5 3
19,932,000 100 100* University of Minnesota
Conclusion: 99.8% of all airborne particles pass through a typical filter. Agglomerating smaller particles into larger ones using Plasma Air ionization improves filter efficiencies.
![Page 5: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/5.jpg)
+ - + -+ - ++ -+
5
The positive effects of a higher ion count
Summary of Frank Chart
Particle Number of Settling Rate Time Required
Diameter Particles per for Spheres to Settle 8 Ft.
(Microns) ft3 of Air 1 (FPM) 2
100 75 59.2 8.1 Sec
10 75 X 103 0.592 13.5 Min
1 75 X 106 0.007 19 Hours
0.1 75 X 109 0.00007 79 Days
0.01 75 X 1012 0 (Brownian) Never
1. Based on air containing 0.00006 grains of impurities per ft3
2. In still air 70º F, density = 1 (S-C factors included)
Conclusion: Particles 1 micron and small (98.5% of all particles) stay airborne. Particles are typically the vehicle that transmit bacteria and virus from person to person. Agglomerating these small particles into larger ones essentially reduces airborne pollutants as they are caught by the filter
![Page 6: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/6.jpg)
+ - + -+ - ++ -+
6
How the Plasma Air technology works
• Molecular activity
1 - Energy is imparted to a neutral oxygen molecule
2 – the molecule is “ionized” (emitting an electron)
3 – this electron is captured by another O2
molecule creating a negative ion
3 – this O2 molecule
becomes a positive ion
4 – These charged ions combine with other O2
molecules forming clusters
![Page 7: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/7.jpg)
+ - + -+ - ++ -+
7
How the Plasma Air technology works
HVAC system airflow carries oxygen molecules over the Plasma Air ionization tube
The ionization tube produces positive and negative oxygen ions
Bi-polar ions are sent through the duct system into the occupied space where they can attack the problem.
![Page 8: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/8.jpg)
+ - + -+ - ++ -+
8
How the Plasma Air technology works
Bipolar technology reproduces mountain elevation ion levels indoors
![Page 9: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/9.jpg)
+ - + -+ - ++ -+
9
Product Performance – Laboratory Testing
Natural Decay 12.8% Bi-Polar Ionization 85.8%
Natural Decay 67.1% Bi-Polar Ionization 91.1%
Effectiveness on Airborne Particles
![Page 10: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/10.jpg)
+ - + -+ - ++ -+
10
Product Performance – Laboratory Testing
Effectiveness on Airborne Bacteria
![Page 11: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/11.jpg)
+ - + -+ - ++ -+
11
Product Performance – Laboratory Testing
Effectiveness on TVOC
![Page 12: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/12.jpg)
+ - + -+ - ++ -+
12
Product Performance – Laboratory Testing
Effectiveness on Formaldehyde
![Page 13: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/13.jpg)
+ - + -+ - ++ -+
13
Product Performance – Laboratory Testing
Effectiveness on Smoke Particulate
![Page 14: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/14.jpg)
+ - + -+ - ++ -+
14
Product Performance – Laboratory Testing
Effectiveness on Smoke VOCs
![Page 15: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/15.jpg)
+ - + -+ - ++ -+
15
Products
![Page 16: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/16.jpg)
+ - + -+ - ++ -+
16
Tube Style
• Plasma Air 100– For use in residential and
commercial applications – up to 3,000 CFM
– Available with C, D, and E length ionization tubes
– Can be installed in duct systems or inside an AHU
– 101 120 Volts– 102 230 Volts
![Page 17: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/17.jpg)
+ - + -+ - ++ -+
17
Tube Style
• Plasma Air 200– For use in residential and
commercial applications – up to 5,000 CFM
– Available with D and E length ionization tubes
– Can be installed in duct systems or inside an AHU
– 201 120 Volts– 202 230 Volts
![Page 18: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/18.jpg)
+ - + -+ - ++ -+
18
Tube Style
• Plasma Air AFS-MF-JB– For use in residential or
commercial applications – Mounting frame is installed
onto duct with sheet metal screws
– Ionizer is mounted to frame with machine screws
– Any voltage, any tube size– Unit includes a pressure
differential switch mounted on back
![Page 19: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/19.jpg)
+ - + -+ - ++ -+
19
Tube Style
• Plasma Air 50E– For use in commercial
applications up to 8,000 CFM
– Equipped with five E tubes
– 51E 120 Volts
– 5 step ionization control knob
– Low voltage BAS communication
• Plasma Air 50F – For use in commercial
applications up to 10,000 CFM– Equipped with five F tubes
– 51F 120 Volts
– 5 step ionization control knob
– Low voltage BAS communication
![Page 20: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/20.jpg)
+ - + -+ - ++ -+
20
Needlepoint
• Plasma Air Mini-ionizer D5– For use in residential or
commercial applications up to 1500 CFM
– Designed to be mounted in outlet of PTAC, FCU or mini-split.
– Small form factor: 2”X1.5”X0.5”
– Power supply for 120V, 230V or 24V will be provided
– Can be OEM or retrofit
![Page 21: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/21.jpg)
+ - + -+ - ++ -+
21
Needlepoint in ductwork
• Model 7000– Needlepoint technology
– Designed to be duct mounted or inside AHU
– Can be powered from 120V, 230V with power supply or accepts 24V AC directly.
– Dry contacts for BAS alarm
– No maintenance!!!• 7100 up to 1,400 CFM• 7200 up to 2,800 CFM• 7300 up to 4,200 CFM• 7400 up to 6,000 CFM
– Larger units can be daisy-chained for higher airflows
– Use on lower pollutant load projects
![Page 22: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/22.jpg)
+ - + -+ - ++ -+
22
Needlepoint in AHU or RTU
• Plasma BAR– Needlepoint technology in long
narrow “Bar” design
– 18” – 96” (L) made of 22 Ga SS304
– Designed to be mounted on entering side of cooling coil in AHU or RTU
– Control Panel can be powered from 12V DC or 24V AC. Power supply required for 120V or 230V AC.
– Dry contacts for BAS alarm
– Needles are recessed to avoid shock
– Interconnecting voltage: 12V DC
– No maintenance!!!
– Won ASHRAE Innovation Award at 2014 AHR show.
![Page 23: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/23.jpg)
+ - + -+ - ++ -+
23
Needlepoint in FCU, Heat Pumps, Splits, PTAC
• Plasma Model 600– Needlepoint “brush” technology in
small, compact design
– Can treat 2,400 CFM
– Dimensions: 2.6” X 1.6” X 1”
– Available in 12V DC, 24V AC, 120V AC and 230V AC voltages.
– Can be used almost anywhere: RTUs, AHUs, Heat Pumps, FCUs, PTACs, Ductless splits.
– Mounted at the fan inlet
– Protected with 0.5 Amp inline fuse
– No maintenance!!!
![Page 24: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/24.jpg)
+ - + -+ - ++ -+
24
Needlepoint EfficacyPathogen Type Pathogen Name Removal
Rate Testing Organization Year Tested
Virus Influenza H1N186.6% Kitasato Research
Center, Japan2011
Bacteria Escherichia Coli99.43% EMSL Analytical, USA
Istanbul University, Turkey2011
Staphylococcus Aureus 91.5% EMSL Analytical, USA 2011
MRSA 99.47% EMSL Analytical, USA 2011
Pseudomonas Aeruginosa 99.9% Istanbul University, Turkey 2011
Mold/FungusCladosporium Cladosporioides
97.69% EMSL Analytical, USA 2011
Dichobotrys Abundans90% Professor Joseph F. Boatman,
USA2006
Penicillium95% Professor Joseph F. Boatman,
USA2006
Aspergillus Niger 97.14% EMSL Analytical, USA 2011
Candida Albicans 36.27% EMSL Analytical, USA 2011
Spore Bacillus Subtilis var Niger 89.3% Istanbul University, Turkey 2011
![Page 25: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/25.jpg)
+ - + -+ - ++ -+
25
Controls
Model CZ6-C / CZ8-AD• Energy Management & IAQ Control Device• Sensors, controller and monitor to minimize
VOCs, particles and odors.• Duct, plenum or space mounting options.• Modulates input voltage to ionizers for
infinite control.• Tracks multiple parameters simultaneously• Continuous 24/7 display on color, hi res,
programmable, touch screen LCD.• Produces graphs and reports or all or
selected parameters• Will prolong tube life.
![Page 26: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/26.jpg)
+ - + -+ - ++ -+
26
Residential Selection Guide
![Page 27: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/27.jpg)
+ - + -+ - ++ -+
27
Commercial Selection Guide
![Page 28: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/28.jpg)
+ - + -+ - ++ -+
28
Product ApplicationsTypical Contaminant
Application Mold Bacteria Viruses Odors VOCs Smoke Chemicals
Homes X X X X X X X
Schools X X X X X
Hospitals X X X X X
Nursing Homes X X X X X
Daycare Centers X X X X
Office Buildings X X X X
Casinos X X X
Restaurants X X X X
Hotels/Motels X X X X
Nail/Beauty Salons X X X
Airport Terminals X X X X X X
Sewage Treatment Plants X X X
Water Treatment Facilities X X X X
Fire Houses X X
Airplanes, Boats, RVs X X X X
![Page 29: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/29.jpg)
+ - + -+ - ++ -+
29
ASHRAE’s IAQ Procedure (and the IMC Exception)
• ASHRAE and the IMC both allow for the reduction of outside air intake by utilizing the IAQ Procedure
ASHRAE International Mechanical Code
![Page 30: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/30.jpg)
+ - + -+ - ++ -+
30
Outside Air Reduction
Cost Analysis of a Typical Project – Ventilation Rate Method vs. IAQ Procedure
St. Andrews School, Silver Spring, MD
Ventilation Rate IAQ Procedure (without Ionization) vs. (with Ionization)
Square Footage 54,300 Sq Ft 54,300 Sq FtTotal Supply Air 56,600 CFM 50,800 CFMTotal Outside Air 25,850 CFM (45%) 10,300 CFM
(20%)Total Cooling Required 222 Tons 158 Tons
Reduction in cooling requirements 64 TonsCost savings due to reduction in cooling $128,000Cost to provide ionization to this school $26,300Net first cost savings to the owner $101,700Ongoing annual savings to the end user $30,080 – $3,800 (annual tube
replacement) = $26,280
![Page 31: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/31.jpg)
+ - + -+ - ++ -+
31
How to Design an IAQ Procedure Project
ASHRAE 62.1 2007 IAQ Procedure Design Compliance
1.Identify Contaminants of Concern (COC)2.Set target concentration for COCs3.Specify design level of acceptability4.Select design approach – one or more of the following:
• Mass balance analysis using ASHRAE’s equations• Expertise in similar buildings• Monitoring• Combination of IAQ and VRP
5.Design documentation1. Maintain records of 1-4 above
![Page 32: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/32.jpg)
+ - + -+ - ++ -+
32
How to Design an IAQ Procedure ProjectASHRAE 62.1 2007 IAQ Procedure Design Compliance
Step 1: Identify Contaminants Of Concern (COCs) In schools, office buildings, and places of assembly, the contaminants of concern are those emitted by the occupants. The ASHRAE Applications handbook lists gaseous contaminants emitted by humans in chapter 45 as:
Notes:1.Because of the relatively high level of ammonia and because it is easily measured, it can be used as an indicator of system efficiency. 2.There are other gaseous contaminants emitted by humans, but their levels are immeasurable with commercial grade detection devices.
Contaminant Generation Rate per Person (ug/hr)
Ammonia 15,600
Carbon Monoxide 10,000
Hydrogen Sulfide 15
Methane 1710
Propane 1.3
![Page 33: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/33.jpg)
+ - + -+ - ++ -+
33
How to Design an IAQ Procedure ProjectASHRAE 62.1 2007 IAQ Procedure Design Compliance
Step 2: Set target concentration limits
The target concentration levels for these contaminants would result if the Ventilation Rate Procedure were used. These concentrations can be determined using the equation in ASHRAE 62.1-2007 Appendix C. Cs − Co = N / Vo
Where: Cs = Concentration in space (liters/liter of air)Co = Concentration in outside air (liters/liter of air) – for most indoor pollutants = 0N = Generation rate per person (liters/min)Vo = Outside air flow rate per person (liters/min)
Example: Ammonia is emitted at the rate of 15,600 µg/hr per person; this is equivalent to 0.00373 liters per minute. For an outside air flow rate of 14.8 CFM per person, the steady state concentration in parts per million would be 1.103.
For a typical classroom with 25people and an outside air flow rate of 14.8 CFM per person, thetarget concentrations are:
Contaminant Concentration (ppm)
Ammonia 1.103
Carbon Monoxide 0.361
Hydrogen Sulfide 0.0005
Methane 0.098
Propane 0.00003
![Page 34: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/34.jpg)
+ - + -+ - ++ -+
34
How to Design an IAQ Procedure Project
ASHRAE 62.1 2007 IAQ Procedure Design Compliance
Step 3: Specify design level of acceptability Per the International Mechanical Code, the design level of acceptability is “equal to or less than” the concentration which would result using the Ventilation Rate Procedure. For a typical classroom with an outside air flow rate of 14.8 CFM per person, these levels are:
Contaminant Concentration (ppm)
Ammonia 1.103
Carbon Monoxide 0.361
Hydrogen Sulfide 0.0005
Methane 0.098
Propane 0.00003
![Page 35: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/35.jpg)
+ - + -+ - ++ -+
35
How to Design an IAQ Procedure Project
ASHRAE 62.1 2007 IAQ Procedure Design Compliance
Step 4: Select a design approach The mass balance analysis using ASHRAE Standard 62.1 Appendix D mass balance equations follows:
![Page 36: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/36.jpg)
+ - + -+ - ++ -+
36
Appendix D - The Mass Balance Method Example
![Page 37: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/37.jpg)
+ - + -+ - ++ -+
37
Appendix D - The Mass Balance Method Example
N+Ev Vo Co(1 - Ef)
Ev (Vo+R Vr Ef)
Cs =
![Page 38: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/38.jpg)
+ - + -+ - ++ -+
38
Appendix D - The Mass Balance Method Example
![Page 39: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/39.jpg)
+ - + -+ - ++ -+
39
How to Design an IAQ Procedure Project
ASHRAE 62.1 2007 IAQ Procedure Design Compliance
Step 5: Documentation Maintain records of documents and calculations used in steps 1 thru 4.
![Page 40: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/40.jpg)
+ - + -+ - ++ -+
40
Validation Study
A study was performed at a completed installation designed using the IAQ Procedure. Contaminant levels were independently validated to verify accuracy of the IAQ Procedure calculations and conformance with Standard 62.1.
![Page 41: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/41.jpg)
+ - + -+ - ++ -+
41
Summary
Why use the IAQ Procedure?
• Reduces exposure to polluted OA• Avoids excessive latent heat load of OA• Provides equipment capacity reduction• Reduces energy requirements• Enhances building life cycle cost• Enhances IAQ and sustainability• Improves system cleanliness• Improves moisture and humidity control
![Page 42: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/42.jpg)
+ - + -+ - ++ -+
42
Worldwide reference projects• Government
– 911 Call Center – Los Angeles, CA– Army Barracks – Fort Benning, GA
• Schools– Indian Creek School - Crownsville, MD – Patrick Henry College – Purcellville, VA – St. Andrews School - Silver Spring, MD– Cass High School – White, GA– Faith Christian School - Grapevine, TX– Georgetown Middle School - KY– Annapolis Area School - Annapolis, MD– Nampa Christian School - Nampa, ID– Winterville Elementary School – Atlanta– Orangewood School – Maitland, FL– Kincaid Elementary School – Marietta Ga
• Churches– Rejoice Lutheran Church – Frisco, TX– Cornerstone Church of Ames – Ames, IA– Community Baptist – Chantilly, VA– Immanuel Lutheran – Wentzville, MO
• Casinos– Peppermill Casino – Reno, NV– Western Village Casino-Sparks, NV– Rainbow Club – Henderson, NV– Peppermill Wendover-Wendover,NV
• Wastewater Treatment– Suffolk County WRF-Hauppauge,NY– Palm Valley WRF – Goodyear, AZ– Santa Paula WWTP-Santa Paula, CA
• Airports– LAX Airport – Los Angeles, CA
• Entire Tom Bradley Terminal• ARCC Building• Central Utility Plant/Maint Bldg• LAX Fire Station
– Van Nuys Airport – Van Nuys, CA– Delta Operations Bldg – Atlanta, GA
• Offices– Mountain America Credit Union - UT– SL Green Graybar Bldg – New York– L&L Holdings 142 West 57th – NYC– Vornado 640 5th Ave lobby – NYC
![Page 43: + - + - + - + + - + Plasma Air Presentation. + - + - + - + + - + 2 Agenda The positive effects of a higher ion count How Plasma Air technology works Product.](https://reader035.fdocuments.us/reader035/viewer/2022062520/5697bfa41a28abf838c970ba/html5/thumbnails/43.jpg)
+ - + -+ - ++ -+
43
Technology Summary
• Bi-polar technology produces both positive and negative oxygen ions which agglomerate airborne particles and reduce odors, VOCs, bacteria and mold.
• Product reproduces mountain-elevation air quality indoors• Technology addresses problem at the source of contaminants – in
the occupied space. Other products rely on return air bringing contaminants back to air handler.
• Strength of ions allows unit to be installed in central duct system providing for a whole system solution.
• Efficacy of technology has been verified by ETL (Intertek-SEMKO)• Plasma Air’s technology is UL listed. See listing at www.ul.com