- Life time control function and automatic delivery of the...
Transcript of - Life time control function and automatic delivery of the...
ENDOMOTORENDOMOTOR
APEXLOCATORAPEXLOCATOR ROOT FILLERROOT FILLER
TRANSILLUMINATIONTRANSILLUMINATION CURINGCURING
DISINFECTIONDISINFECTION NEGATOSCOPENEGATOSCOPE
OBTURATOROBTURATORENDOMOTOR - SAFENDOMOTOR SAF-
- Life time control function and automaticdelivery of the Ni-Ti files
- Large programs’ library for Ni-Ti files system,including new RECIPROC system
- Dentsply Maillefer
VDW:
FKG Dentaire:
SybronEndo:
Sendoline:
MicroMega:
R&S:
System GT
AlphaKite System, EasyShape System
- Mtwo System, RECIPROC
- RaCe & S-Apex, BioRaCe
- Twisted Files 3 Endo
- NiTi-TEE, S5
- Hero 642 Hero Shaper, EndoFlare Hero Apical Revo-S R-Endo
- CMA System
, ,
, К
, , , ,
: , ,
,
ProTaper Universal GT Series X ProFile PathFile
-
FlexMaster
Komet:
- rotation regimes
- selection of files rotation angle at “Reciprocation” regime
- programmable cells
- setting of speed and limit torque individually for each file
2 :
12
“ ”Normal and “ ”Reciprocation
“ ”Normal “ ”Reciprocation
а) b)
1
2
3
4
5
6
7
8
9
- GUTTA-PACK connectionAutomatic activation “ ”of mode at handpiece
- 4 working regimes for thermopluggers of and taper
Adjustment of the thermoplugger working temperature
Automatic control for heating and cooling processes
6%, 8%, 10% 12%
-
-
- High-speed for work with SAF – filesendomotor( )manufactured by the firm RedentNova
ENDOMOTOR-SAF4
- of mode at handpiece MOTOR-SAF connection“ ”Automatic activation
- Adjustment of the frequency r m of the fileepeated otion
“ ”MOTOR-SAF
- entrance to for
- of remained working resource
Automatic system the program fixed cartridge
Automatic control
- Automatic delivery of the required file
at
“ ” connection
handpiece
MOTOR-DC
for each file
during every step of canal preparation
- of working instruments
for the whole usage period
Storage and sterilization directly in cartridge - guarantee of safety
- Autonomous apexlocator for localization of apical narrowingof the root canal (apex)
- Special mode for filling of root canalsmaterials
thewith restorative
- root filler rotation speed
Function-
Adjustment of the
“ ”AutoStop at the reaching of limit torque value
Realization of practically the whole line of endodontic instrumentswithin the single deviceA of the system into device correspondingto the connected working handpiecePossibility of permanent at the expense of additionalworking handpieces purchasing
O through Internet
UTOMATIC RECONFIGURATION
FUNCTIONAL INCREASING
PERATIONAL PROGRAM UPDATE
time
1.
2.
3.
4.
At present our company design new additional instruments
.
is ing which provide followingfunctions:- during endodontic processing-
Irrigation of the root canalgutta-percha warming and delivery
GENERAL DVANTAGES OF THE SYSTEMA
- of mode at handpiece connectionAutomatic activation LED-D“ ”
Base Mode
- 5 disinfection regimes: «Base Mode» programmed by the user and 4
standard regimes programmed under ASEPTIM technology
Adjustment of the photoactivator emission power and programmed timer
for disinfection exposition at
rogrammed timer of solution exposure time at all working regimes
-
“ ”
- P
9 - viewing of dentalX-ray films at the display
in transient light
Special mode for
- of mode at handpiece connectionAutomatic activation LED-C“ ”
- Adjustment of the photoactivator energy luminosity
3 working regimes: «General», «Soft» and Pulse»
Programmed timer for polymerization exposition
- «
-
- Adjustment of the observation window size
Base complete set
------ ( 01)---
Control block with coverCable LEMO/ IEEE-1394Cable with electrodes for apexlocationFoot control pedalMains chargerCartridge for NiTi files #Sterilizable stickers for cartridgesStand for handpieces of 4 modulesCD with Operation Manual
- Technical document
+
-- «- « С”- «-- Three additional modules for stand-- « » with a special cover-holder
of cartridges with working files
Handpiece for obturation with thermoplugger «GUTTA-PACK»Handpiece for trans-illumination LED-T»Handpiece for polymerization LED-Handpiece for disinfection LED-D”Two additional c
Foam rubber sponges ( 50 mm, 25 sponges/pck)Ultrasound bath UltraEST-FSM
Full complete set
- ««
6%)
Handpiece-micromotor MOTOR-DC»- High-speed handpiece-micromotor MOTOR-SAF»
(
artridges for NiTi files
- Base complete set
The base complete set of delivery is completed with any handpieces for choice the user
General technical characteristics of “EndoEST-Assistant”:
Power source Li-Ion (2 V m h- х3,7 ; 2000 А/ ); LCD display resolution diagonal . ” paletteOverall dimensions control block mm Weight g
- - ( 240 х 320, 3 2 , 262К);- (171х144х 112) / - ~ 500 .
2 APEXLOCATOR. : Sterilizable electrodes file clip and lip clip- Diapason of measurements from to scale units Diapason of apical shelf formation from to scale units from apex
-- 3,0 -0,2 ; - 0,1 0,5
1. :ENDOMOTOR MOTOR-Handpiece-micromotor- torque 15 - 6- Rotation angle in and counterclockwise direction at Reciprocation mode ° ° °- File working resource from to
with 2 color light-emitting diode indicator“ ”DCLimit - from 0, to 5,5 Ncm (step 0,05 Ncm) / Rotation speed from 150 to 00 rpm (step 10 rpm)
clockwise “ ” - from 90 to 360 (step 45 );- 100 00%
3. :ROOT FILLER MOTOR-Handpiece-micromotor- Rotation speed - from to 4 rpm step rpm Limit torque 4 1 Ncm150 00 ( 10 ); - ,
“ ”DC
5. :OBTURATOR Handpiece- Working temperature of thermoplugger from (
Time of heating up to specified temperature - (0,4-2,6) sec- 100
- ;
“ ”GUTTA-PACK with light-emitting diode indicator and thermoplugger
Time of cooling down to ° /140 1 sec~ 60 С - 2300 С 50 С)to step / from 210 to 570 F (step 90 F)
F
7. : “ С” (CURING LED-Н - LED 5 )- - (462-465)- of the photoactivator - from 200 to 1000 mW/сm2 (step 200 mW/сm2)- - 5 30 ( 5 )
andpiece Light source ( W)Emission spectrum peak nmEnergy luminosityTimer for polymerization exposition from to sec step sec
BLUE
6. : “ Т”TRANSILLUMINATION LED-Handpiece Light source ( W)Emission spectrum peak nmMaximal emission brightness lm
( - LED 5 )- - (590-595)- - 100±20
ORANGE
8. : “ ” (DISINFECTION LED-DН - LED 5 )- - (625-635)- - 300 800 ( 100 )- - 30 180 ( 30 )- - 0 60 ( 10 )
andpiece Light source ( W)Emission spectrum peak nmPower emission from to mW step mWTimer for disinfection exposition from to sec step secTimer of “waiting” (solution exposure time) from to sec step sec
RED
9. :NEGATOSCOPE LEDsBrightness of observation screen 20) cand mDimensions of observation screen Height mm Width mm
- - (140 ± / 2- : - 30,40 , - 30,40,50,60
-Light source WHIGHT
4. :ENDOMOTOR-SAF Handpiece- Working frequency motion of the file from to cycles/min (step 500 cycles/min)- 3000 5000
“ ”MOTOR-SAF
CJSC Geosoft DentBuild.14, Ap.16, 3-rd Mytishchinskaya st.,
Moscow, 129626, Russial / Fax (
E-mail: [email protected] Web: www.geosoft.ru
“ ”
Те . : + 7 (495) 663-22-11 multichannel),
Your regional dealer: