Dependable. Bid Spec Sheets... · 2017. 10. 6. · The Gasboy® Atlas series is rugged, durable,...

24
Worldwide leader in solutions for fleet and commercial markets. Choose from the industry’s leading range of pump and dispenser models, with features and options designed specifically to meet the unique needs of fleet operators. The Gasboy ® Atlas series is rugged, durable, reliable and perfectly suited for the tough fleet fueling environment. Electronic and mechanical choices are lit for unattended applications. High flow, Super High Flow, and Ultra High models provide fast fueling for large vehicles. Satellite dispensers allow simultaneous fueling of saddle tanks to reduce fueling time. Gasboy Atlas pumps and dispensers are compatible with a full range of Gasboy Fleet Management Systems to help you track and manage your fleet better. From the most simple system to the most comprehensive one, Gasboy offers turnkey solutions to simplify your operation. Atlas ® pumps & dispensers for fleet operations Atlas 9100 Series Atlas 9800 Series Dependable. Durable. Satellite

Transcript of Dependable. Bid Spec Sheets... · 2017. 10. 6. · The Gasboy® Atlas series is rugged, durable,...

  • Worldwide leader in solutions for fleet and commercial markets.www.gasboy.com

    Choose from the industry’s leading range of pump and dispenser models, with features and options designed specifically to meet the unique needs of fleet operators.

    The Gasboy® Atlas series is rugged, durable, reliable and perfectly suited for the tough fleet fueling environment. Electronic and mechanical choices are lit for unattended applications. High flow, Super High Flow, and Ultra

    High models provide fast fueling for large vehicles. Satellite dispensers allow simultaneous fueling of saddle tanks to reduce fueling time.

    Gasboy Atlas pumps and dispensers are compatible with a full range of Gasboy Fleet Management Systems to help you track and manage your fleet better. From the most simple system to the most comprehensive one, Gasboy offers turnkey solutions to simplify your operation.

    Atlas® pumps & dispensers for fleet operations

    Atlas™ Features Option Summary

    P-7067D | Printed in the U.S.A. | © 2012 | 03122 | 7300 W. Friendly Ave., Greensboro, NC 27410 (336) 547-5700

    Atlas 9100 Series Atlas 9800 Series

    Dependable.

    Durable.

    Satellite

    Feature Description 9853 9840 9850 9823 9872 9862 CW 9862 WW 9153 215/216Q

    Approvals UL and cUL Listed, NCWM, Measurement Canada (MC) S S S S S NCWM, MC NCWM, MC S S

    Working Pressure 50 psi maximum S S S S S S S S S

    Unit of Measure Gallons (liters optional) S S S S S S S S S

    Motors / Voltages

    1 HP CD - 115V/60Hz - (230V/50Hz optional) S S — S S — — S —

    1-1/2 HP CD - 230V/60Hz - (230V/50Hz optional) — — S — — — — — —

    3/4 HP CD 380V/50Hz/3-phase O O — O O — — O —

    Pump Models10 vane rotary with air separator S S — S S — — S —

    High speed rotary vane with air separator — — S — — — — — —

    Solenoid Valve 2-stage valve for Preset Operation (PP) 1” 1-½” 1-½” 1” 1” ¾” ¾” 1” —

    Filters Internal spin-on style (F) S S — S S Strainer Strainer S —

    Discharge Hose Connection - NPT 1” 1¼” 1¼” 1” ¾” NPT 1” BSPP 1” BSPP 1”1” (215)

    1¼” (216)

    Satellite Piping Satelitte piping connection (S) - display only O O O — — — — O —

    Inlet Island Connection - NPT 1½” 2” 2” 1½” 1½” 1” BSPP 1” BSPP 1½” 1½”

    Housing G90 Galvanized Steel 13 GA 13 GA 13 GA 11 GA 13 GA 13 GA 13 GA 13 GA 12 GA

    Panels

    Lockable removable - Painted Galvanized Steel (std) - gauge 20 20 20 16 20 20 20 20 16

    Replaceable - Kooline Stainless Steel - 22 gauge O O O — O — O O —

    Replaceable - Type 304 Stainless Steel - 20 gauge — — — — — — — — O

    Sheathing

    Replaceable - Painted G60 Galvanized Steel (std) - gauge 20 20 20 16 20 20 20 20 16

    Replaceable - Kooline Stainless Steel - 22 gauge O O O — O O O O —

    Replaceable - Type 304 Stainless Steel - 20 gauge — — — — — — — — O

    Computer / RegisterElectronic Register - Volume only display S S S S S S S — —

    Mechanical Register - VR10 volume only — — — — — — — S —

    Electronic Display 1” backlighted LCD S S S S S S S — —

    Interface Options

    Pulser - 10:1 or 100:1 volume (CC or CX) — — — — — — — O —

    RS-485 - Gasboy CFN, Islander, or TopKat O O O O O O O — —

    Pulse Output I/F O O O O O O O — —

    DC conduit and junction box (D) S S S — S S S — —

    Keytrol (EK) — — — — — — — O —

    Brand Panel Lighting Lighted brand panel (L) O O O — O O O O —

    Totalizers

    Electronic Totalizer S S S S S S S — —

    Non-resettable Electro-Mechanical totalizer O O — — O O O — —

    Non-resettable Mechanical Totalizer — — O O — — — S —

    Nozzle PositionSide Load S S S — S — S S S

    Front Load (Z) O O O S O S O — O

    Hose Retractors

    Internal hose retractor (I) O O — — — — O O —

    Internal hose reel — — — — — S — — —

    High hose retractor - external post mounted O O O O — — O O O

    AST ApplicationsPressure Regulating Valve Model 52A - suction pumps only O — — O — — — O —

    9850 Above Ground Tank Kit - suction pumps only — — O — — — — — —

    Warranty12 month - parts & labor S S S S S S S S S

    Extended Warranty - 2, 3, 4, or 5-years O O O O O — — O O

    Miscellaneous

    ATC (Canada Only) O O O — — — — — —

    Hand Crank (K) — — — — — — — O —

    Display Power Fail Backup S S S S S S S — —

    Internal Cabinet Heater (DEF only) — — — — — S — — —

    Balanced Vapor Recovery O — — O — — — O —

    Healy Universal Kit Compatible O — — — — — — O —

    Hose, Nozzle, Swivel, Breakaway O O O O O O O O O

    230V

    S = Standard, O = Optional

  • Worldwide leader in solutions for fleet and commercial markets.www.gasboy.com

    Mechanical pumps and dispensers

    Model Number Type Hoses Products Motors Meters

    9153K Pump Single 1 (1) 1 hp c.d. Gilbarco CFT

    9152KTW1 Pump Twin 1 (1) 1 hp c.d. Gilbarco CFT

    9153KTW1M Pump Twin 1 (2) 1 hp c.d. Gilbarco CFT

    9153KTW2 Pump Twin 2 (2) 1 hp c.d. Gilbarco CFT

    9153KX Dispenser Single 1 n/a Gilbarco CFT

    9153KXTW1 Dispenser Twin 1 n/a Gilbarco CFT

    9153KXTW2 Dispenser Twin 2 n/a Gilbarco CFT

    High Flow (up to 22 gpm/83 lpm)*

    Model Number Works With Hoses Products GPM(LPM)* Motors Meters

    215Q 9153KX9853KX

    Single 1 Up to 21 n/a n/a

    215Q-Z Single 1 Up to 21 n/a n/a

    215QTW-Z Twin 1 Up to 21 n/a n/a

    216Q 9850KX9840KX9850K

    Single 1 Up to 40 n/a n/a

    216Q-Z Single 1 Up to 40 na/ n/a

    216QTW-Z Twin 1 Up to 40 n/a n/a

    Satellite dispensers

    Electronic pumps and dispensers

    Model Number Type Hoses Products Motors Meters

    9850K Pump Single 1 (1) 1½ hp c.d. Liquid Controls

    9850KTW3 Pump Combo 1 (1) 1½ hp c.d. Liquid Controls

    9850KX Dispenser Single 1 n/a Liquid Controls

    9850KXTW1 Dispenser Twin 1 n/a Liquid Controls

    9850KXTW2 Dispenser Twin 2 n/a Liquid Controls

    9850KXTW3 Dispenser Combo 1 n/a Liquid Controls

    Ultra High Flow (up to 50 gpm/189 lpm)*

    Model Number Type Hoses Products Motors Meters

    9840K Pump Single 1 (2) 1 hp c.d. (2) Gilbarco CFT

    9840KX Dispenser Single 1 n/a (2) Gilbarco CFT

    Super High Flow (up to 40 gpm/151 lpm)*

    Model Number Type Hoses Products Motors Meters

    9853K Pump Single 1 (1) 1 hp c.d. Gilbarco CFT

    9852KTW1 Pump Twin 1 (1) 1 hp c.d. Gilbarco CFT

    9853KTW1M Pump Twin 1 (2) 1 hp c.d. Gilbarco CFT

    9853KTW2 Pump Twin 2 (2) 1 hp c.d. Gilbarco CFT

    9853KX Dispenser Single 1 n/a Gilbarco CFT

    9853KXTW1 Dispenser Twin 1 n/a Gilbarco CFT

    9853KXTW2 Dispenser Twin 2 n/a Gilbarco CFT

    High Flow (up to 22 gpm/83 lpm)*

    Model Number Type Hoses Products Nozzle Position Meters

    9872KX F Dispenser Single 1 Side (1) C+

    9872KX FZ Dispenser Single 1 Front (1) C+

    9872KXTW1 Z Dispenser Twin 1 Front (2) C+

    E85 Electronic Dispensers

    Model Number Type Application Nozzle Position Hoses Products Sides Meters

    9862KX-Z Dispenser Cold Weather Front 1 1 1 (1) Coriolis Mass Flow

    9862KX-WW Dispenser Warm Weather Side 1 1 2 (1) Coriolis Mass Flow

    9862KX-ZWW Dispenser Warm Weather Front 1 1 1 (1) Coriolis Mass Flow

    DEF Electronic Dispensers

  • Worldwide leader in solutions for fleet and commercial markets.www.gasboy.com

    Mechanical pumps and dispensers

    Model Number Type Hoses Products Motors Meters

    9153K Pump Single 1 (1) 1 hp c.d. Gilbarco CFT

    9152KTW1 Pump Twin 1 (1) 1 hp c.d. Gilbarco CFT

    9153KTW1M Pump Twin 1 (2) 1 hp c.d. Gilbarco CFT

    9153KTW2 Pump Twin 2 (2) 1 hp c.d. Gilbarco CFT

    9153KX Dispenser Single 1 n/a Gilbarco CFT

    9153KXTW1 Dispenser Twin 1 n/a Gilbarco CFT

    9153KXTW2 Dispenser Twin 2 n/a Gilbarco CFT

    High Flow (up to 22 gpm/83 lpm)*

    Model Number Works With Hoses Products GPM(LPM)* Motors Meters

    215Q 9153KX9853KX

    Single 1 Up to 21 n/a n/a

    215Q-Z Single 1 Up to 21 n/a n/a

    215QTW-Z Twin 1 Up to 21 n/a n/a

    216Q 9850KX9840KX9850K

    Single 1 Up to 40 n/a n/a

    216Q-Z Single 1 Up to 40 na/ n/a

    216QTW-Z Twin 1 Up to 40 n/a n/a

    Satellite dispensers

    Electronic pumps and dispensers

    Model Number Type Hoses Products Motors Meters

    9850K Pump Single 1 (1) 1½ hp c.d. Liquid Controls

    9850KTW3 Pump Combo 1 (1) 1½ hp c.d. Liquid Controls

    9850KX Dispenser Single 1 n/a Liquid Controls

    9850KXTW1 Dispenser Twin 1 n/a Liquid Controls

    9850KXTW2 Dispenser Twin 2 n/a Liquid Controls

    9850KXTW3 Dispenser Combo 1 n/a Liquid Controls

    Ultra High Flow (up to 50 gpm/189 lpm)*

    Model Number Type Hoses Products Motors Meters

    9840K Pump Single 1 (2) 1 hp c.d. (2) Gilbarco CFT

    9840KX Dispenser Single 1 n/a (2) Gilbarco CFT

    Super High Flow (up to 40 gpm/151 lpm)*

    Model Number Type Hoses Products Motors Meters

    9853K Pump Single 1 (1) 1 hp c.d. Gilbarco CFT

    9852KTW1 Pump Twin 1 (1) 1 hp c.d. Gilbarco CFT

    9853KTW1M Pump Twin 1 (2) 1 hp c.d. Gilbarco CFT

    9853KTW2 Pump Twin 2 (2) 1 hp c.d. Gilbarco CFT

    9853KX Dispenser Single 1 n/a Gilbarco CFT

    9853KXTW1 Dispenser Twin 1 n/a Gilbarco CFT

    9853KXTW2 Dispenser Twin 2 n/a Gilbarco CFT

    High Flow (up to 22 gpm/83 lpm)*

    Model Number Type Hoses Products Nozzle Position Meters

    9872KX F Dispenser Single 1 Side (1) C+

    9872KX FZ Dispenser Single 1 Front (1) C+

    9872KXTW1 Z Dispenser Twin 1 Front (2) C+

    E85 Electronic Dispensers

    Model Number Type Application Nozzle Position Hoses Products Sides Meters

    9862KX-Z Dispenser Cold Weather Front 1 1 1 (1) Coriolis Mass Flow

    9862KX-WW Dispenser Warm Weather Side 1 1 2 (1) Coriolis Mass Flow

    9862KX-ZWW Dispenser Warm Weather Front 1 1 1 (1) Coriolis Mass Flow

    DEF Electronic Dispensers

  • Worldwide leader in solutions for fleet and commercial markets.www.gasboy.com

    Choose from the industry’s leading range of pump and dispenser models, with features and options designed specifically to meet the unique needs of fleet operators.

    The Gasboy® Atlas series is rugged, durable, reliable and perfectly suited for the tough fleet fueling environment. Electronic and mechanical choices are lit for unattended applications. High flow, Super High Flow, and Ultra

    High models provide fast fueling for large vehicles. Satellite dispensers allow simultaneous fueling of saddle tanks to reduce fueling time.

    Gasboy Atlas pumps and dispensers are compatible with a full range of Gasboy Fleet Management Systems to help you track and manage your fleet better. From the most simple system to the most comprehensive one, Gasboy offers turnkey solutions to simplify your operation.

    Atlas® pumps & dispensers for fleet operations

    Atlas™ Features Option Summary

    P-7067D | Printed in the U.S.A. | © 2012 | 03122 | 7300 W. Friendly Ave., Greensboro, NC 27410 (336) 547-5700

    Atlas 9100 Series Atlas 9800 Series

    Dependable.

    Durable.

    Satellite

    Feature Description 9853 9840 9850 9823 9872 9862 CW 9862 WW 9153 215/216Q

    Approvals UL and cUL Listed, NCWM, Measurement Canada (MC) S S S S S NCWM, MC NCWM, MC S S

    Working Pressure 50 psi maximum S S S S S S S S S

    Unit of Measure Gallons (liters optional) S S S S S S S S S

    Motors / Voltages

    1 HP CD - 115V/60Hz - (230V/50Hz optional) S S — S S — — S —

    1-1/2 HP CD - 230V/60Hz - (230V/50Hz optional) — — S — — — — — —

    3/4 HP CD 380V/50Hz/3-phase O O — O O — — O —

    Pump Models10 vane rotary with air separator S S — S S — — S —

    High speed rotary vane with air separator — — S — — — — — —

    Solenoid Valve 2-stage valve for Preset Operation (PP) 1” 1-½” 1-½” 1” 1” ¾” ¾” 1” —

    Filters Internal spin-on style (F) S S — S S Strainer Strainer S —

    Discharge Hose Connection - NPT 1” 1¼” 1¼” 1” ¾” NPT 1” BSPP 1” BSPP 1”1” (215)

    1¼” (216)

    Satellite Piping Satelitte piping connection (S) - display only O O O — — — — O —

    Inlet Island Connection - NPT 1½” 2” 2” 1½” 1½” 1” BSPP 1” BSPP 1½” 1½”

    Housing G90 Galvanized Steel 13 GA 13 GA 13 GA 11 GA 13 GA 13 GA 13 GA 13 GA 12 GA

    Panels

    Lockable removable - Painted Galvanized Steel (std) - gauge 20 20 20 16 20 20 20 20 16

    Replaceable - Kooline Stainless Steel - 22 gauge O O O — O — O O —

    Replaceable - Type 304 Stainless Steel - 20 gauge — — — — — — — — O

    Sheathing

    Replaceable - Painted G60 Galvanized Steel (std) - gauge 20 20 20 16 20 20 20 20 16

    Replaceable - Kooline Stainless Steel - 22 gauge O O O — O O O O —

    Replaceable - Type 304 Stainless Steel - 20 gauge — — — — — — — — O

    Computer / RegisterElectronic Register - Volume only display S S S S S S S — —

    Mechanical Register - VR10 volume only — — — — — — — S —

    Electronic Display 1” backlighted LCD S S S S S S S — —

    Interface Options

    Pulser - 10:1 or 100:1 volume (CC or CX) — — — — — — — O —

    RS-485 - Gasboy CFN, Islander, or TopKat O O O O O O O — —

    Pulse Output I/F O O O O O O O — —

    DC conduit and junction box (D) S S S — S S S — —

    Keytrol (EK) — — — — — — — O —

    Brand Panel Lighting Lighted brand panel (L) O O O — O O O O —

    Totalizers

    Electronic Totalizer S S S S S S S — —

    Non-resettable Electro-Mechanical totalizer O O — — O O O — —

    Non-resettable Mechanical Totalizer — — O O — — — S —

    Nozzle PositionSide Load S S S — S — S S S

    Front Load (Z) O O O S O S O — O

    Hose Retractors

    Internal hose retractor (I) O O — — — — O O —

    Internal hose reel — — — — — S — — —

    High hose retractor - external post mounted O O O O — — O O O

    AST ApplicationsPressure Regulating Valve Model 52A - suction pumps only O — — O — — — O —

    9850 Above Ground Tank Kit - suction pumps only — — O — — — — — —

    Warranty12 month - parts & labor S S S S S S S S S

    Extended Warranty - 2, 3, 4, or 5-years O O O O O — — O O

    Miscellaneous

    ATC (Canada Only) O O O — — — — — —

    Hand Crank (K) — — — — — — — O —

    Display Power Fail Backup S S S S S S S — —

    Internal Cabinet Heater (DEF only) — — — — — S — — —

    Balanced Vapor Recovery O — — O — — — O —

    Healy Universal Kit Compatible O — — — — — — O —

    Hose, Nozzle, Swivel, Breakaway O O O O O O O O O

    230V

    S = Standard, O = Optional

  • Worldwide leader in solutions for fleet and commercial markets.

    Nobody understands the tough demands of fueling on the city yard or unattended site better than Gasboy. We build the industry’s most reliable, rugged dispensers. And now we have an Atlas E85 dispenser specifically designed and UL approved for E85 fueling. It’s part of the industry’s most

    comprehensive selection of Gasboy, Gilbarco®, Veeder-Root® and Red Jacket® products for alternative fuels. All from Gilbarco Veeder-Root, your turnkey solution provider for fleet fueling.

    Gasboy Atlas E85 dispenser for fleet operations

    New fuel.

    Same toughenvironment.

    ® ®

  • www.gasboy.com

    P-7072| Printed in the U.S.A. | © 2011 | 031102 | 7300 W. Friendly Ave., Greensboro, NC 27410 (336) 547-5000

    Dependability. Durability. - Atlas™ Pumps & Dispensers for Retailers

    Model Number Type Hoses Products Nozzle Position Meters

    9872KX F Dispenser 1 1 Side (1) C+

    9872KX FZ Dispenser 1 1 Front (1) C+

    9872KXTW1 Z Dispenser 2 1 Front (2) C+

    New fuel. Same tough environment. − Gasboy® Atlas® E85 dispenser for fleet operations

    S - Standard; O - Optional

    Quality means lower costs in the long run.We use the highest quality materials and craftsman-ship to bring you the best, most reliable equipment you can buy. It means you enjoy the lowest total cost of ownership and maximum uptime for the long run.> Brightly lit brand area and display> Improved flow-through meter increases reliability> Heavy duty G90 galvanized frame> Rigid structural foam bezel for long life.> Field-proven E85 hydraulics from the Gilbarco Encore® series> Fully removable door for easier access and service with plenty of room to work> Removable side and top sheathing in black or customer specified color, or stainless steel side and top panels

    > Customizable graphic options on lower door> Standard 1-year warranty with optional extended warranty

    Seamless compatibility delivers hassle-free operation and maximum uptime.The Gasboy Atlas E85 dispensers have our standard interfaces (RS-485 and Pulse Out) available for compatibility with your existing fleet management system or site controller. Our turnkey Gasboy solutions are designed and tested for compatibility. You get hassle-free operation and maximum uptime. > Gasboy PLUS> Gasboy CFN III> Many 3rd party controllers

    Your best choice for consistent image and easy operation.We offer a variety of models and options. Choose the configuration that best meets your needs and matches your existing fuel island. > Single front load> Single side load> Twin hose front load

    Superior support.Gasboy products are supported by the industry’s most comprehensive network of distributors and Authorized Service Contractors. So you enjoy maximum uptime and the lowest total cost of ownership for the long term.

    Feature Description Feature DescriptionApprovals UL listed, NCWM S

    Electronic Display Volume only front display. 1” backlighted LCD. Maximum SWorking Pressure 50 psi maximum S 999.000 gallons or 9999.00 liters.

    Units of MeasureGallons S

    Interface Options

    Card System Interface: RS-485 interface for direct connectionO

    Liters O to Gasboy CFN System, Islander, or TopKAT

    Voltages115V 60 HZ S Card System Interface - pulse output: selectable pulse/gallon

    O230V 50 HZ O outputs for interfacing with fuel control systems.

    Meters C+ Meter with electronic calibration S DC conduit and junction box (D) S

    Solenoid Valve 1” solenoid valve for slow-down preset operation (PP) S Brand Panel Lighting Lighted brand panel (L) O

    Filters Integrated internal spin-on filter (F) - E85 Rated S Totalizers Non-settable Electro-Mechanical O

    Discharge ¾” NPT SNozzle Positions

    Side Mount S

    Inlet 1½” NPT S Front Mount O

    Frame Welded G90 galvanized steel - 13 gauge SWarranty

    Parts and labor - 1-year S

    PanelsLockable removable panels - painted 20 gauge G60 galvanized steel S Parts and labor - 2-5 year O

    Lockable removable panels - Stainless steel 22 gauge Kooline O

    Miscellaneous

    Battery backup (B) O

    SheathingPainted replaceable sheathing - 22 gauge G60 galvanized steel S Hose: ¾” (E-85 Compatible) O

    Stainless steel Type 304 Kooline - 22 gauge O Automatic nozzles, breakaway valves, swivels, and shear valve OComputer/Register Electronic Register: Volume only display. Electronic totalizer S

    (E-85 Compatible)

    displayed on LCD by magnetic switch.

  • Global leader in turnkey solutions for commercial fleet operators.

    Integrating DEF into your existing fleet management system is easy with Gasboy. The proven user interface of our Atlas DEF dispenser will be familiar to your drivers and works seamlessly with your existing fleet management systems and applications. Add DEF to your system and manage all aspects of your fleet using one reliable system.

    The Atlas DEF dispenser comes in two models: Cold Weather and Warm Weather. The Cold Weather

    DEF dispenser is designed to prevent DEF freezing and crystallization with a heated cabinet. Both models have stainless steel hydraulics to protect against corrosion and use an innovative, Weight and Measures approved Coriolis Mass Flow Meter measures DEF accurately and reliably.

    On the inside, the Atlas DEF dispenser’s unique design brings to bear all the best practices we’ve learned from extensive DEF experience in Europe

    and in the retail market in North America. The Atlas DEF dispenser is rugged, durable and perfectly suited for the tough fleet fueling environment.

    Choose Atlas, and you get the industry’s best commercial DEF dispenser, fleet management system compatibility, and service network. With Gasboy, managing DEF is easier than you think.

    Gasboy® Atlas® Diesel Exhaust Fluid (DEF) Dispensers

    ManagingDEF

    is easier thanyou think.

  • The Gasboy Atlas DEF dispenser is built to meet your needs and comes in two models.

    Cold Weather DEF DispenserThe Cold Weather DEF Dispenser is the first of its kind, keeping your fleet up and running in any weather.> Heated and insulated hydraulic cabinet with an internal hose storage to protect the DEF from freezing or crystallizing down to -30oC> Enclosed heated nozzle boot> Thermostat controlled, saving you money on power usage

    Warm Weather DEF DispenserFor climates where DEF freeze prevention is not required, we offer our Warm Weather DEF Dispenser. > Comes without a heater, providing Gasboy quality at an even better value> Conventional nozzle boot and hose management is standard> Optional hose extension available

    www.gasboy.com

    Both Atlas DEF dispenser models are equipped with a Coriolis Mass Flow Meter for exceptional accuracy.

    > Mass flow technology delivers industry leading accuracy – even as the product characteristics change> No moving parts that wear or stick, delivering reliable operation> Measures mass directly and independently from viscosity and density changes, allowing the meter to be unaffected by temperature, conductivity, and solid content> Weight & Measures approved for transfer sales> Electronic calibration for accuracy

    Coriolis Mass Flow Meter

    Coriolis Mass Flow Meter

    Cold Weather Atlas DEF

  • Global leader in turnkey solutions for commercial fleet operators.

    High hose retractor option for

    Warm Weather DEF

    Warm Weather Atlas DEF

    Model Number Type Application Nozzle Position Hoses Products Sides Meters

    9862KX Z Dispenser Cold Weather Front 1 1 1 (1) Coriolis Mass Flow

    9862KX WW Dispenser Warm Weather Side 1 1 2 (1) Coriolis Mass Flow

    9862KX ZWW Dispenser Warm Weather Front 1 1 1 (1) Coriolis Mass Flow

    Cold Weather = temperatures down to -30C; Warm Weather = temperatures down to -12C

  • www.gasboy.com

    Gasboy® Atlas® DEF Dispensers — Features & Options

    P-7073 | Printed in the U.S.A. | © 2012 | 01122 | 7300 W. Friendly Ave., Greensboro, NC 27410 (336) 547-5700

    Feature Description 9862KXZ 9862KX WW 9862KK ZWW

    Application Cold Weather - down to -30C S n/a n/a

    Warm Weather - down to +12F n/a S S

    Approvals NCWM, Measurement Canada S S S

    Working Pressure 50 psi maximum S S S

    Unit of Measure Gallons S S S

    Liters O O O

    Voltages 115V 60HZ S S S

    230V 50HZ n/a n/a n/a

    Nozzle Positions Front Mount - Enclosed and heated boot S n/a n/a

    Side Mount - Open boot n/a S n/a

    Front Mount - Open boot n/a n/a S

    Meters SSt Coriolis Mass Flow Meter with electronic calibration S S S

    Solenoid Valve SSt 3/4” solenoid valve for slow-down preset operation (PP) S S S

    Filters / Strainer SSt strainer with 100-micron mesh removable strainer S S S

    Discharge 1” BSPP S S S

    Inlet 1” BSPP Bottom S S S

    1” BSPP Boot Side n/a O O

    1” BSPP Non-boot Side O O O

    Hose Retractors Hose Hook n/a S S

    Internal hose retractor (I) n/a O O

    Internal hose reel assy S n/a n/a

    High-hose retractor; post-mounted retractor with spring return reel n/a O O

    Heater Dual stage heater for DEF hydraulic cabinet S n/a n/a

    Frame Welded G90 galvanized steel - 13 gauge S S S

    Panels Lockable removable panels - powder coated 20 gauge G60 galvanized steel S S S

    Lockable removable panels - stainless steel 22 gauge Kooline n/a O O

    Sheathing Powder coated replacable sheathing - 22 gauge G60 galvanized steel S S S

    Stainless steel type 304 Kooline - 22 gauge O O O

    Bezel & Dialface Black rigid structrual foam bezel with clear polycarbonate window and blackscreen polycarbonate dialface (black letters on white background)

    S S S

    Brand Panel Lighting Lighted brand panel (L) O O O

    Computer / Register Electronic register: Volumne only display; Electronic totalizer displayed on LCD by magnetic switch S S S

    Electronic Display Volume only display; 1” backlighted LCD; Maximum 999.000 gallons or 9999.00 liters; w/DLT S S S

    Interface Options Card system interface: RS-485 interface for direct connection to Gasboy CFN System, Islander or TopKat O O O

    Card system interface - pulse output: selectable pulse/gallon outputs for interfacing with fuel control systems O O O

    DC conduit and junction box (D) S S S

    TopKat Mounting Mounting kit for TopKat n/a O O

    Totalizers Non-settable electro-mechanical S O O

    Sub Drive Relay Remote pump drive relay - 40 amp rating O O O

    Warranty Parts & labor - 1 year S S S

    Extended warranty n/a n/a n/a

    Miscellaneous Hose: 1” BSPP O O O

    Automatic nozzles, breakaway valves and swivels O O O

    S = Standard; O = Optional, n/a = Not Available

  • Above Ground Storage Tank Solutions The Only Customized Choice for Fleet & Retail Applications

    Gasboy® Atlas™ Above-Ground Storage Tank (AST) pumps are the industry’s only customized solution that can be sealed by Weights & Measures for custody transfer/retail sale applications. They feature a heavy-duty 1 HP motor with a durable pump and meter for long life.

    Part of a Complete SystemWhen used with Gasboy TopKAT®, Series 1000 Fleet Key, Islander® or CFN® fuel management controllers, you have a complete, single-source solution for your municipal, fleet fueling or retail sales requirements.

    Add a Gasboy fuel management system now or later as your needs change. Detailed reports track fuel, drivers and vehicles. They are available on-site or can be accessed from a remote location. Systems also provide access control for better security and fuel management.

    Or, use Gasboy AST pumps as standalone products for private use and farm applications today.

    Two ModelsASTRA 9823K is a split remote pump with electronic register for easy access and volume read-out viewing – just the right height!

    Compact 9123K is a self-contained, single pump with combined mechanical register.

    Fleet Management • Commerical Dispensers • Liquid Transfer Pumps • Service and Support

    ASTRA 9823K

    Compact 9123K

  • ASTRA 9823K

    Compact 9123K

    Sta

    ndar

    d

    Op

    tion/

    Acc

    esso

    r

    Sta

    ndar

    d

    Op

    tion/

    Acc

    esso

    r

    Regulatory Approvals: UL and cUL listed, NCWM, Measurement Canada • •Working Pressure: 50 psi maximum • •Motor/Voltage: 1 HP continuous duty motor 115V/60HZ • •Motor/Voltage: 1 HP continuous duty motor 230V/50 Hz • •Pump: 10 vane rotary pump with integrated air separator • •Meter: CFT flow through positive displacement 4-piston meter. Accurate to 0.25% • •Valve: 1” solenoid valve for slow-down preset operation (PP) • •Filter: integrated internal spin-on filter (F) • •Discharge: 1” NPT black iron • •Inlet: 1-½” NPT rear inlet • •Housing/Cabinet: Painted G90 galvanized steel • •Dimensions: 27.7” W x 25.4” H x 22.5” D • •Lockable removable panels • •Finish: White hydraulic cabinet, black remote register with blue tedlar faceplate •Finish: Black top, sides, and back panel. White front panel •Mounting: 4 stainless steel “L” feet slotted for anchor bolts. • •Pulser: Dual phase 1000:1 with error detection •Pulser: 10:1 or 100:1 for key or card systems •Flow Rate: 20 gpm rated* • •Remote Electronic Register: Volume only (gallons or liters) front display. 1” backlighted LCD. Maximum 999.000 gallons or 9999.00 liters. Liters denoted by :R” model suffix option. Electronic Totalizer is displayed on LCD by magnetic switch. Reads up to 999999. Battery backed.

    Mechanical Register: Four-wheel reset gallons/liters only. Reset interlock reads up to 999.9 gallons/liters. Totalizer reads up to 999999.9.

    Mechanical Totalizer for pumping unit cabinet: Mechanical non-resettable totalizer – reads up to 9999999.9

    Internal Filter: Standard flow or water alert • •External High FlowFilter Kits: Includes Presssure Regulating Valve Model 52A 9048577) - required when hydraulic unitmounted at or below tank maxium fuel level

    adapter, filter element, pipe fittings • •

    • •

    o

    oquires “V” option.

    ctable pulse/gallon outputs for interfacing rol systems. 1, 10, 250, or 500 pulses per

    de Mount (015128), Standalone Pedestal (042082).

    pedestal.

    Slowdown Valve: reduces flow for accurate preset shutoff by fuel control systems • •Cable (C08864): Connects meter and pumping unit to remote register. Shielded,4-conductor, 18 awg. Specify length.

    Card System Interface for CFN or TopKAT: RS-485 interface for direct connection to Gasboy CFN System, Islander or TopKAT

    Card System Interface – Pulse Output: Selewith Gasboy Series 1000 and other fuel contgallon. 1, 10, or 100 per liter.

    Mounting Kits: Front Mount (015127), Si •

    TopKAT Mounting Kit (C35753): Mounts TopKAT above ASTRA remote register with •

    Nozzle Boot: Front mount. Flips up to activate pump • •Hose: ¾” or 1”. Specify length. Standard or Vapor Recovery • •Vapor Recovery – Balanced vapor recovery system

    o Vapor Piping (“V”) – includes internal vapor piping and co-axial splitter (and vapor boot and hook for 9123K) Vapor Ready (“Y”) – includes internal vapor piping, co-axial splitter, and adapter to use standard hose. Vapor Complete – includes external co-ax hanging hardware and high retriever. Re

    High Hose Retractor: Post-mounted retractor with enclosed spring return reel. Keeps hose out of vehicle lane when idle, eases handling during fueling, and allows use of longer hose.

    • •

    Automatic nozzles, breakaway valves, and swivels • •

    * For maximum flow rate, use 1” hose and nozzle. For lower flow rate, use ¾” hose and nozzle.

    Astra 9823K and Compact 9123K Specifications

    Footprint and elevation drawing available on page 30 of MDE 4567A.

    WarningGasboy products must be installed by a qualified installer and used in conformance with all building, fire and environmental codes, and other safety requirements applicable to their installation and use, including, but not limited to NFPA 30, NFPA 30A and NFPA 70. This product is only part of a fuel dispensing system and additional equipment and accessories, such as, but not limited to, breakaway connectors, shear valves, pressure regulators and other safety devices may be necessary to meet the applicable codes. Qualified installers shall be familiar with fuel systems installations under the above stated building, fire and environmental codes and other safety requirements for the particular type of installation. Gasboy dispensers shall not be used for direct fueling of aircraft without filters, separators and other equipment necessary to ensure product purity. All sales subject to Gasboy standard warranty.

    P-7065 AST 01071 Printed in USA

    ©2007 Gasboy • 7300 West Friendly Ave. / PO Box 22087 Greensboro NC • 27420-2087 USATelephone: 1 800 444 5579 • Fax: 336 547 5920 • www.gasboy.com • [email protected]

  • Worldwide leader in solutions for fleet and commercial markets.

    Sometimes the best solutions are the most simple ones. Gasboy Atlas pumps and dispensers provide retailers with all the basics for retail fueling.

    Durable, reliable, and proven pumps and dispensers are available in electronic and mechanical models to meet your needs. They can interface

    with your point of sale system for use at your primary fueling island. Or, use Atlas pumps and dispensers to offer secondary products like kerosene.

    Dependable.

    Gasboy® Atlas® Pumps & Dispensers for Retailers

    Durable.

  • Model Number Type Hoses Products Motors Meters

    8753K Pump Single 1 (1) 1 hp c.d. Gilbarco CFT

    8752KTW1 Pump Twin 1 (1) 1 hp c.d. Gilbarco CFT

    8753KTW1M Pump Single 1 (2) 1 hp c.d. Gilbarco CFT

    8753KTW2 Pump Twin 2 (2) 1 hp c.d. Gilbarco CFT

    8753KX Dispenser Single 1 n/a Gilbarco CFT

    8753KXTW1 Dispenser Twin 1 n/a Gilbarco CFT

    8753KXTW2 Dispenser Twin 2 n/a Gilbarco CFT

    www.gasboy.com

    P-7068A | Printed in the U.S.A. | © 2008 | 1208 | 7300 W. Friendly Ave., Greensboro, NC 27410 (336) 547-5000

    Dependability. Durability. - Atlas™ Pumps & Dispensers for Retailers

    Atlas™ Features Option Summary

    Model Number Type Hoses Products Motors Meters

    8853K Pump Single 1 (1) 1 hp Gilbarco CFT

    8852KTW1 Pump Twin 1 (1) 1 hp Gilbarco CFT

    8853KTW1M Pump Twin 1 (2) 1 hp Gilbarco CFT

    8853KTW2 Pump Twin 2 (2) 1 hp Gilbarco CFT

    8853KX Dispenser Single 1 n/a Gilbarco CFT

    8853KXTW1 Dispenser Twin 1 n/a Gilbarco CFT

    8853KXTW2 Dispenser Twin 2 n/a Gilbarco CFT

    8753 8853 88538753Regulatory Approvals: UL and cUL listed, Measurement Canada, NCWM S SWorking Pressure: 50 psi maximumUnit of Measure: Gallons (Liters optional)Motor/Voltage: 1HP continuous duty motor 115V/60HZVoltage: 230V/50HZ and 380V/50HZ/3-Phase O O

    S SS SS S

    Pump: 10 vane rotary pump with integrated air separator1” solenoid valve for slow-down preset operation (PP)Integrated internal spin-on filter (F)External spin-on type filter O ODischarge: 1” NPT black ironSatellite Piping - dispensers only (S) O O1-1/2” NPT inletHousing: 13 Gallon painted G90 galvanized steelLockable, removable panels - painted 20 gauge G60Lockable, removable panels - Stainless steel 22 gauge Kooline O OPainted replaceable sheathing - G60 galvantized (22 gallon)Stainless steel sheathing - Kooline (22 gallon) O OElectronic computer: Displays money, volume, and PPU Electronic totalizer records 10-digits and displays 6-digits on the LCD display

    NN

    SS

    Mechanical computer: VR10 - Money, volume, and PPU, includes integrated totalizer and power reset

    S N

    Electronic display: Money, volume, and PPU front display. 3/4” backlighted LCD 6-digit money and volume, 4-digit PPU N S

    S S

    S SS SS S

    S S

    S SS SS S

    Pulser: (10:1 or 100:1 volume) for key or card systems (CC or CX) O NPulser: (100:1 money) for key or card systems (CM) OGilbarco 2-wirePulse output

    NN S

    ON

    High hose retractor: post-mounted retractor with enclosed spring return reel

    Electro-mechanical non-settable totalizer (7-digit)Nozzle position: Side mountInternal hose retractor (I)

    Lighted brand panel (L)

    AST Application: Pressure Regulating Valve Model 52A (9048577)12 month parts and labor warranty24 month parts and labor warrantyATC (Canada only)

    Balanced vapor recovery system (Healy Universal Kit compatible)Hand crank (K)

    Hose: 3/4” or 1” (specify length) - standard or vapor recoveryAutomatic nozzles, breakaway valves, and swivelsProgrammable pump reset (export only)Auto-on (export only)

    S SON

    S SS SO OO O

    O OS S

    ONOO OO OO O

    OO

    N

    NN

    S = Standard, O = Optional, N = Not available

    Mechanical pumps & dispensers - 22GPM*

    Electronic pumps & dispensers - 22GPM*

    *Flow rate at ideal test conditions. Actual flow rate may vary based on conditions at installation.

    Member of NATSO, Inc.

  • Electronic Fleet Bid Spec Bid Specification – Gasboy Atlas Electronic Fleet Products 1. Product

    1.1. Fleet non computing – Electronic register 2. Type

    2.1. Pump – integrated suction pump and motor 2.2. Dispenser (“X”) – for use with remote pumping unit

    3. Flowrate – capable of delivery in typical installations 3.1. Standard Flow = 15 gpm / 57 lpm 3.2. High Flow = 22 gpm / 83 lpm 3.3. Super High Flow = 40 gpm / 151 lpm 3.4. Ultra High Flow = 50 gpm / 194 lpm

    4. Models 4.1. Single product single hose – one product unit with a single hose 4.2. Single product twin hose (TW1) – one product unit with two hoses 4.3. Two product twin hose (TW2) – two product unit with one hose per product (two hoses total) 4.4. Master / Satellite Combo (TW3) – one product master with one hose for master and separate hose for satellite in

    same frame. 4.5. Single product twin hose High Flow suction pump (TW1M) – one product with two hoses and dedicated pump/motor

    per hose. 5. Hardware Requirements

    5.1. Display 5.1.1. Electronic Fleet: Volume only (gallons or liters) displays. 1" (2.5 cm) back lighted LCD displays. Maximum

    999.000 gallons or 9999.00 liters (9850 models: 9999.00 gallons or 9999.00 liters). Displays both front and back of cabinet, except models with front load nozzle boot option only display on side with corresponding nozzle boot. Last transaction maintained for more than 15 minutes by on board capacitor. Backlight by 6 Super-brite LEDs for long life.

    5.2. Pulser (Electronic type) 5.2.1. Dual phase 1000:1 with error detection.

    5.3. Meter 5.3.1. Four-piston, positive displacement flow-through CFT meter bolsters resistance to fuel contamination with

    self-cleaning central chamber 5.3.2. 9840: Two (2) parallel four-piston, positive displacement flow-through CFT meters manifolded to a single

    hose position. The CFT meter bolsters resistance to fuel contamination with self-cleaning central chamber 5.3.3. 9850K Series: six-step, rotary motion, positive displacement meter.

    5.4. Pump with air separator (Pump models only) 5.4.1. Standard and High Flow Pumps: Rotary 10 vane pump with an air eliminator and self-priming built into

    pump casting. Belt driven. Pumps include check valve and field replaceable shaft seal. Ten (10) vanes provide quieter operation and better suction lift.

    5.4.2. Super hi Pumps and TW1M (9840): Two (2) rotary 10 vane pumps per hose position with an air eliminator and self-priming built into pump casting. Belt driven. Ten (10) vanes provide quieter operation and better suction lift.

    5.4.3. Ultra-hi Pumps (9850): High speed rotary vane pump, belt driven. 5.5. Motor (Pump models only)

    5.5.1. 1 Hp continuous duty explosion proof enclosed motor on Standard, High Flow, and Super-hi flow pump models (115V or 230V). Two (2) motors provided on Super-hi and TW1M.

    5.5.2. 1-1/2 Hp continuous duty explosion proof enclosed motor on Ultra-hi model 9850K. 5.6. Filter

    5.6.1. Internal Filter: Spin on filter canister located before meter and valve to ensure product purity and protect critical components from contamination. Available in 10-micron or 30-micron particulate or water alert filtration with 1-1/2” opening. One filter provided per hose position on standard and high flow models. Two filters per hose position on super-hi (9840) model. Available on Standard, High, and Super-hi Flow Models.

    SP-7177A 01/13 Gasboy │7300 W Friendly Ave│Greensboro, NC 27410 1

  • Electronic Fleet Bid Spec 5.6.2. Internal Strainer: 80-mesh removable strainer included in filter adapter housing. One strainer per hose

    position for standard and high flow, two strainers per hose position for super hi flow (9840) models. 5.6.3. Internal Strainer (9850): 40-mesh removable strainer basket, one per hose position.

    5.7. Valves 5.7.1. Standard & High-Flow (8752/8753/8852/8853/9152/9153/9852/9853): 1” solenoid valve that may be

    cleaned or replaced without breaking down pipe work – standard on dispensers and pumps. 5.7.2. Super-hi and Ultra-hi (9840/9850): 1-1/2” solenoid valve – standard on dispensers, optional on pumps.

    5.8. Piping 5.8.1. Standard, High Flow, and Super-hi: 1” brazed copper feedline and 1” black iron threaded discharge pipe. 5.8.2. Ultra-hi: 1-1/2” black iron threaded pipe.

    5.9. Junction Box 5.9.1. Explosion-proof field wiring junction box for AC wiring. Includes two 1” NPT field wiring openings and one

    ¾” NPT opening for DC control interface wiring. 5.10. Totalizer

    5.10.1. Electronic: Displayed on LCD by magnetic switch activation. Displays up to 999,999. Electronically backed up.

    5.10.2. Electro-mechanical - 7 digit non-resettable electro-mechanical totalizer. 5.11. Hose Retriever

    5.11.1. Hose hook standard 5.11.2. Internal spring driven cable retriever (optional)

    6. Frame and Panels 6.1. Frame

    6.1.1. Hot dip 13 gauge G90 galvanized steel (0.093”) with welded corners for rigidity and added strength. 6.2. Cosmetic panels - Hot dip G60 painted galvanized steel or stainless steel

    6.2.1. Replaceable top and sides in black or stainless steel, with lower panels painted white or optional specified color or stainless steel.

    6.2.2. Lower panels locked to prevent tampering 6.2.3. Finish – High quality polyester powder coat over e-coat primer. Gas, oil, and UV resistant. 6.2.4. Stainless Steel: Type 304 Kooline SSt with embossed brush finish.

    6.3. Bezel and Dialface Graphics 6.3.1. Bezel: High strength structural foam for improved rigidity painted black with one-piece clear polycarbonate

    window. Gas, oil and UV resistant. 6.3.2. Dialface: Back screened one-piece polycarbonate overlay (black print on white background per customer

    spec) with cutouts as needed for displays. Gas, oil and UV resistant. 6.3.3. Brand: Replaceable polycarbonate back screened brand panel. Gas, oil and UV resistant. Backlighted by

    fluorescent bulb (optional). 7. Unit of Measure (select one)

    7.1. US Gallons 7.2. Liters (“R”)

    8. Performance / Ratings 8.1. Working pressure = 50 psi rated working pressure 8.2. Meter accuracy = +/- 0.25% 8.3. Flow Rating: Delivery rating is max test rates at the dispenser discharge. Actual rates will vary depending on

    installation conditions, product dispensed, and accessory items. Twin models are single hose flow. 8.3.1. Standard Flow (SF) = 15 gpm – uses ¾” bushing at dispenser discharge 8.3.2. High Flow (HF) = 22 gpm 8.3.3. Super Hi Flow (SHF) = 40 gpm 8.3.4. Ultra-hi Flow (UHF) = 50 gpm

    8.4. Temperature Rating: Ambient -30ºC (-22ºF) to +55ºC (+131ºF) 8.5. Relative Humidity: 20% to 95% non-condensing

    9. Fuel Compatibility 9.1. Suitable for use with conventional motor fuels, oxygenated fuel blends up to 15% ethanol, and bio-diesel blends up

    to 20% (B20) 9.2. Alternative fuels: E85, B21 to B100: Use 9872KX models.

    10. Power Requirements - (select one) 10.1. 115VAC/60Hz (ex 9850)

    SP-7177A 01/13 Gasboy │7300 W Friendly Ave│Greensboro, NC 27410 2

  • Electronic Fleet Bid Spec 10.2. 230VAC/60Hz 10.3. 230VAC/50Hz 10.4. 230VAC/60Hz with 380VAC motor – 3 phase (ex 9850) 10.5. 230VAC/50Hz with 380VAC motor – 3 phase (ex 9850)

    11. System Interface (electronic type only - optional) 11.1. Gasboy CFN RS485 interface for direct connection to control systems (electronic fleet only) 11.2. Pulse Output. Selectable pulse/gallon outputs for Gasboy Series 1000, FleetKey and other fuel control systems.

    12. Inlet connection: 12.1. Standard and High: 1-1/2” (3.8 cm) NPT. 12.2. Super-High and Ultra-High: 2” (5cm) NPT.

    13. Discharge: 13.1. Standard & High flow: 1” NPT, convert to ¾” with customer supplied NPT reducer. 13.2. Super & Ultra-hi flow: 1-1/4” NPT with bushing to 1” NPT supplied.

    14. Above Ground Tank Applications 14.1. All dispenser models are approved for AST applications 14.2. Pump models approved with Model 52A Pressure Regulating (Anti-siphon) Valve; except 9840K and all TW1M

    pump models are not recommended due to excessive inlet restrictions. 14.3. Model 9850K pump approved using Aboveground Tank Kit (032060)

    15. Regulatory Approvals 15.1. Safety: UL or cUL approved (File# MH1941) 15.2. Weights & Measures: Meter accuracy meets requirements for retail custody transfer, sealable by local officials.

    15.2.1. National Conference of Weights & Measures certified 15.2.2. Measurement Canada (MC) certified.

    15.3. FCC Part 15 Compliant 15.4. NYCFD approved

    16. Warranty 16.1. 12 month parts & labor standard 16.2. Optional 2, 3, 4, and 5 year parts & labor warranty available

    17. Standard 17.1. INTERNAL FILTER ADAPTER (“F”): Provides adapter inside the cabinet for a filter element to help ensure product

    purity. Specify standard or high flow and element type. Not available for 9850K series. 18. Options

    18.1. FRONT LOAD NOZZLE BOOT (“Z”): Relocates standard side-oriented nozzle boot to front of cabinet for lane-oriented fueling applications. Electronic units only.

    18.2. SATELLITE PIPING (“S”): Provides internal piping and union for connecting to a satellite dispenser for convenient fueling of saddle tanks. Available on remote dispensers and 9850K.

    18.3. SLOWDOWN VALVE (“PP”): Reduces delivery to a slow flow for accurate preset shut-off by fuel control systems. Standard on all models except 9850.

    18.4. STAINLESS STEEL PANELS: Provide durable finish. Type 304 Kooline SSt with embossed brush finish. All stainless steel panels ("SS"). Stainless steel front and back panels only ("SSA"). Stainless steel top and sides only ("SSTS").

    18.5. TopKAT PLUS MOUNTING KIT (“D5”): Includes pump mounting hardware for the TopKAT PLUS fuel management system.

    18.6. LIGHT (“L”): Illuminates products panels and register areas. Two fluorescent bulbs. Specify 115V or 230V. Not available with EK option.

    18.7. SUBMERSIBLE PUMP DIRECT DRIVE RELAY: For the direct drive of submersible pumps up to 3/4 hp at 115VAC or 1-1/2 hp at 230 VAC. Rated 40 amps. Alternative to external relay box. Specify single or twin relays.

    18.8. VAPOR RECOVERY READY (“Y”): Special vapor recovery nozzle boot, hanger and splitter cutout in frame and sheathing.

    18.9. VAPOR RECOVERY COMPLETE: Complete vapor recovery kits, includes special nozzle boot, hanger, splitter, hose and nozzle. Pumping units include internal vapor piping. Field installation required.

    18.10. INTERNAL HOSE RETRACTOR (“I”) - Keeps hoses out of the fueling lane. 18.11. CFN or TOPKAT RS485 (Electronic Fleet only) - for direct connection to Gasboy control systems. 18.12. PULSE OUTPUT (Electronic units only) – Selectable pulse/gallon outputs for Gasboy Series 1000, FleetKey and

    other fuel control systems. (select one) 18.12.1. Single pulse output

    SP-7177A 01/13 Gasboy │7300 W Friendly Ave│Greensboro, NC 27410 3

  • Electronic Fleet Bid Spec 18.12.2. Dual pulse output (single product single hose only) 18.12.3. Dual Channel Twin Hose pulse output (twin hose – two outputs per hose).

    18.13. FILTER KITS, EXTERNAL - Help ensure product purity. Single or Dual filter kits include adapter, element, and pipe fittings. Available in 10-micron or 30-micron particulate or water alert filtration with 1-1/2” opening, 5” diameter by 11” long. Specify standard or hydrosorb element.

    18.14. HIGH HOSE RETRACTOR (“H”) - Eases hose handling during fueling and keeps hose up and out of the way to reduce wear and run-over damage. High, post-mounted with enclosed spring return reel

    18.15. FILTER CAP – Replaces internal spin-on filter for applications where a filter is not required. 18.16. PRESSURE REGULATOR VALVE (048577) – Gasboy Model 52A prevents product from leaking from the air

    elimination vent in aboveground tank suction pump installations (required accessory). TW2 models require two valves.

    18.17. ABOVEGROUND TANK KIT (032060) – Solenoid operated anti-siphon kit for 9850K only. Prevents product from leaking from the air elimination vent in aboveground tank suction pump installations (required accessory).

    19. Accessories 19.1. Hose 19.2. Breakaway 19.3. Swivel 19.4. Nozzle

    20. Approved Suppliers 20.1. Electronic Fleet – Gasboy 9852K, 9853K, 9840K, or 9850K

    SP-7177A 01/13 Gasboy │7300 W Friendly Ave│Greensboro, NC 27410 4

  • Mechanical Fleet Bid Spec Bid Specification – Gasboy Atlas Mechanical Fleet Products 1. Product

    1.1. Fleet non computing – Mechanical register 2. Type

    2.1. Pump – integrated suction pump and motor 2.2. Dispenser (“X”) – for use with remote pumping unit

    3. Flowrate – capable of delivery in typical installations 3.1. Standard Flow = 15 gpm / 57 lpm 3.2. High Flow = 22 gpm / 83 lpm

    4. Models 4.1. Single product single hose – one product unit with a single hose 4.2. Single product twin hose (TW1) – one product unit with two hoses 4.3. Two product twin hose (TW2) – two product unit with one hose per product (two hoses total) 4.4. Single product twin hose High Flow suction pump (TW1M) – one product with two hoses and dedicated pump/motor

    per hose. 5. Hardware Requirements

    5.1. Display 5.1.1. Mechanical Fleet: Veeder-Root® mechanical registers (VR10) with power reset interlock. Displays on both

    sides include gallons or liters to 999.9 units. Includes non-resettable mechanical totalizer. 5.2. Reset (Mechanical register models only)

    5.2.1. Power Reset (standard) – motor driven mechanical register reset 5.2.2. Manual Reset (optional) – spring loaded mechanical register reset

    5.3. Meter 5.3.1. Four-piston, positive displacement flow-through CFT meter bolsters resistance to fuel contamination with

    self-cleaning central chamber 5.4. Pump with air separator (Pump models only)

    5.4.1. Standard and High Flow Pumps: Rotary 10 vane pump with an air eliminator and self-priming built into pump casting. Belt driven. Pumps include check valve and field replaceable shaft seal. Ten (10) vanes provide quieter operation and better suction lift.

    5.4.2. TW1M: Two (2) rotary 10 vane pumps per hose position with an air eliminator and self-priming built into pump casting. Belt driven. Ten (10) vanes provide quieter operation and better suction lift.

    5.5. Motor (Pump models only) 5.5.1. 1 Hp continuous duty explosion proof enclosed motor on Standard, and High Flow pump models (115V or

    230V). Two (2) motors provided on TW1M. 5.6. Filter

    5.6.1. Internal Filter: Spin on filter canister located before meter and valve to ensure product purity and protect critical components from contamination. Available in 10-micron or 30-micron particulate or water alert filtration with 1-1/2” opening. One filter provided per hose position on standard and high flow models. Available on Standard and High Flow Models.

    5.6.2. Internal Strainer: 80-mesh removable strainer included in filter adapter housing. One strainer per hose position for standard and high flow.

    5.7. Valves 5.7.1. Standard & High-Flow (9152/9153): 1” solenoid valve that may be cleaned or replaced without breaking

    down pipe work – standard on dispensers and pumps. 5.8. Piping

    5.8.1. Standard & High Flow: 1” brazed copper feedline and 1” black iron threaded discharge pipe. 5.9. Junction Box

    5.9.1. Explosion-proof field wiring junction box for AC wiring. Includes two 1” NPT field wiring openings and one ¾” NPT opening for DC control interface wiring.

    5.10. Totalizer 5.10.1. Totalizer – (Mechanical Type). Mechanical non-resettable totalizer. Located on back panel. Reads up to

    9,999,999.9. Required for resale applications. 5.11. Hose Retriever

    SP-7180A 01/13 Gasboy│7300 W Friendly Ave│Greensboro, NC 27410 1

  • Mechanical Fleet Bid Spec 5.11.1. Hose hook standard 5.11.2. Internal spring driven cable retriever (optional)

    6. Frame and Panels 6.1. Frame

    6.1.1. Hot dip 13 gauge G90 galvanized steel (0.093”) with welded corners for rigidity and added strength. 6.2. Cosmetic panels - Hot dip G60 painted galvanized steel or stainless steel

    6.2.1. Replaceable top and sides in black or stainless steel, with lower panels painted white or optional specified color or stainless steel.

    6.2.2. Lower panels locked to prevent tampering 6.2.3. Finish – High quality polyester powder coat over e-coat primer. Gas, oil, and UV resistant. 6.2.4. Stainless Steel: Type 304 Kooline SSt with embossed brush finish.

    6.3. Bezel and Dialface Graphics 6.3.1. Bezel: High strength structural foam for improved rigidity painted black with one-piece clear polycarbonate

    window. Gas, oil and UV resistant. 6.3.2. Dialface: Back screened one-piece polycarbonate overlay (black print on white background per customer

    spec) with cutouts as needed for displays. Gas, oil and UV resistant. 6.3.3. Brand: Replaceable polycarbonate back screened brand panel. Gas, oil and UV resistant. Backlighted by

    fluorescent bulb (optional). 7. Unit of Measure (select one)

    7.1. US Gallons 7.2. Liters (“R”)

    8. Performance / Ratings 8.1. Working pressure = 50 psi rated working pressure 8.2. Meter accuracy = +/- 0.25% 8.3. Flow Rating: Delivery rating is max test rates at the dispenser discharge. Actual rates will vary depending on

    installation conditions, product dispensed, and accessory items. Twin models are single hose flow. 8.3.1. Standard Flow (SF) = 15 gpm – uses ¾” bushing at dispenser discharge 8.3.2. High Flow (HF) = 22 gpm

    8.4. Temperature Rating: Ambient -30ºC (-22ºF) to +55ºC (+131ºF) 8.5. Relative Humidity: 20% to 95% non-condensing

    9. Fuel Compatibility 9.1. Suitable for use with conventional motor fuels, oxygenated fuel blends up to 15% ethanol, and bio-diesel blends up

    to 20% (B20) 9.2. Alternative fuels: E85, B21 to B100: Use 9872KX models.

    10. Power Requirements - (select one) 10.1. 115VAC/60Hz 10.2. 230VAC 50/60Hz 10.3. 230VAC/50Hz with 380VAC motor – 3 phase

    11. Inlet connection: 11.1. Standard and High: 1-1/2” (3.8 cm) NPT.

    12. Discharge: 12.1. Standard & High flow: 1” NPT, convert to ¾” with customer supplied NPT reducer.

    13. Above Ground Tank Applications 13.1. All dispenser models are approved for AST applications 13.2. Pump models approved with Model 52A Pressure Regulating (Anti-siphon) Valve; except 9840K and all TW1M

    pump models are not recommended due to excessive inlet restrictions. 14. Regulatory Approvals

    14.1. Safety: UL or cUL approved (File# MH1941) 14.2. Weights & Measures: Meter accuracy meets requirements for retail custody transfer, sealable by local officials.

    14.2.1. National Conference of Weights & Measures certified 14.2.2. Measurement Canada (MC) certified.

    14.3. FCC Part 15 Compliant 14.4. NYCFD approved

    15. Warranty 15.1. 12 month parts & labor standard 15.2. Optional 2, 3, 4, and 5 year parts & labor warranty available

    SP-7180A 01/13 Gasboy│7300 W Friendly Ave│Greensboro, NC 27410 2

  • Mechanical Fleet Bid Spec 16. Standard

    16.1. INTERNAL FILTER ADAPTER (“F”): Provides adapter inside the cabinet for a filter element to help ensure product purity. Specify standard or high flow and element type.

    17. Options 17.1. SATELLITE PIPING (“S”): Provides internal piping and union for connecting to a satellite dispenser for convenient

    fueling of saddle tanks. Available on remote dispensers. 17.2. SLOWDOWN VALVE (“PP”): Reduces delivery to a slow flow for accurate preset shut-off by fuel control systems.

    Standard on all models. 17.3. STAINLESS STEEL PANELS: Provide durable finish. Type 304 Kooline SSt with embossed brush finish. All

    stainless steel panels ("SS"). Stainless steel front and back panels only ("SSA"). Stainless steel top and sides only ("SSTS").

    17.4. LIGHT (“L”): Illuminates products panels and register areas. Two fluorescent bulbs. Specify 115V or 230V. Not available with EK option.

    17.5. VAPOR RECOVERY READY (“Y”): Special vapor recovery nozzle boot, hanger and splitter cutout in frame and sheathing.

    17.6. VAPOR RECOVERY COMPLETE: Complete vapor recovery kits, includes special nozzle boot, hanger, splitter, hose and nozzle. Pumping units include internal vapor piping. Field installation required.

    17.7. ELECTRICAL KEYTROL PULSER & MOUNTING KITS (Mechanical Only) - Include necessary pulsers, top cabinet panels, and wiring for factory-installed Gasboy Electrical Keytrol. (select one)

    17.7.1. For gallons, specify 10:1 kits 17.7.2. For liters, specify 1:1 kits. 17.7.3. Single Dispensers: For 1 Master EK console (“EK+1:1” or “EK+10:1”). For 1 Master & 1 Auxiliary console

    (“EK+M/A, 1:1” or “EK+M/A, 10:1”) 17.7.4. Twin Dispensers: For 2 Master EK consoles (“EK+M/M, 1:1” or “EK+M/M, 10:1”). For 1 Split Master

    (“EK+SPL, 1:1” or “EK+SPL, 10:1”) 17.8. INTERNAL HOSE RETRACTOR (“I”) - Keeps hoses out of the fueling lane. 17.9. PULSERS (Mechanical units only) - Convert register revolutions to electrical pulses for connection to fuel control

    systems. (select one) 17.9.1. Volume 1:1 (“+1:1 PLSR”) for liter applications. 17.9.2. Volume 10:1 (“CX”) ratios. 17.9.3. Volume 100:1 (“CC”) ratios.

    17.10. ACCUMULATIVE TOTALIZER REVERSED (“FT”): Field installed kit to move the cumulative totalizer from the back to front display panel – Mechanical Fleet only.

    17.11. HAND CRANK (“K”) Ideal for regions where power outages are likely. Allows dispensing by hand at a rate of 0.6 liters per stroke.

    17.12. MANUAL RESET (“J”) – Manual mechanical register reset for use with hand crank. 17.13. FILTER KITS, EXTERNAL - Help ensure product purity. Single or Dual filter kits include adapter, element, and pipe

    fittings. Available in 10-micron or 30-micron particulate or water alert filtration with 1-1/2” opening, 5” diameter by 11” long. Specify standard or hydrosorb element.

    17.14. HIGH HOSE RETRACTOR (“H”) - Eases hose handling during fueling and keeps hose up and out of the way to reduce wear and run-over damage. High, post-mounted with enclosed spring return reel

    17.15. FILTER CAP – Replaces internal spin-on filter for applications where a filter is not required. 17.16. PRESSURE REGULATOR VALVE (048577) – Gasboy Model 52A prevents product from leaking from the air

    elimination vent in aboveground tank suction pump installations (required accessory). TW2 models require two valves.

    18. Accessories 18.1. Hose 18.2. Breakaway 18.3. Swivel 18.4. Nozzle

    19. Approved Suppliers 19.1. Mechanical Fleet – Gasboy 9152K, 9153K

    SP-7180A 01/13 Gasboy│7300 W Friendly Ave│Greensboro, NC 27410 3

  • Commercial DEF Bid Spec SP-7118A

    Bid Specification Outline – Gasboy Atlas Commercial DEF Products 1. Product

    1.1. Fleet non computing – Electronic register 2. Type

    2.1. Dispenser (“X”) – for use with remote pumping unit 3. Flowrate – capable of delivery in typical installations

    3.1. Standard Flow = 10 gpm / 38 lpm rating 4. Models

    4.1. Cold Weather Application (CW) – with internal Heater 4.1.1. Single product single hose – one product unit with a single hose – front load only

    4.2. Warm Weather Application (WW) – no heater 4.2.1. Single product single hose – side load 4.2.2. Single product single hose – front load

    5. Hardware Requirements 5.1. Display

    5.1.1. Volume only (gallons or liters) displays. 1" (2.5 cm) back lighted LCD displays. Maximum 999.000 gallons or 9999.00 liters (9850 models: 9999.00 gallons or 9999.00 liters). Displays both front and back of cabinet, except models with front load nozzle boot option only display on side with corresponding nozzle boot. Last transaction maintained for more than 15 minutes by on board capacitor. Backlight by 6 Super-brite LEDs for long life.

    5.2. Pulser 5.2.1. Dual phase 1000:1 with error detection.

    5.3. Meter 5.3.1. Mass Flow Meter: Coriolis type stainless steel. Measures mass directly and independently from viscosity

    and density changes. No moving parts. UL Listed for Class 1 Div 2 Zone. 5.3.2. Electronic calibration: Automatically creates a pulse factor based on exact volume dispensed into a prover

    can. W&M sealable calibration switch. 5.4. Piping

    5.4.1. Stainless steel ¾” tubing and 5/8” ID hose. 5.5. Filter

    5.5.1. Internal Strainer: Stainless steel housing with 100-micron stainless steel mesh removable strainer. One strainer per hose position.

    5.6. Valves 5.6.1. Two-stage 3/4” solenoid valve. Stainless steel body with DEF compatible diaphragm and seals. Explosion

    proof coil, UL listed for Class 1 Div 2 Group D. 5.7. Junction Box

    5.7.1. NEMA 4X field wiring junction box for AC wiring. Includes one opening for 1” field wiring conduit and one opening for ¾” conduit for DC control interface wiring.

    5.8. Totalizer 5.8.1. Electronic: Displayed on LCD by magnetic switch activation. Displays up to 999,999. Electronic back up. 5.8.2. Electro-mechanical - 7 digit non-resettable electro-mechanical totalizer (optional).

    5.9. Heater (CW only) 5.9.1. Heater and Fan Assembly to heat the internal hydraulic cabinet and prevent DEF freezing in cold

    temperature, rated 750W. Secondary heater for nozzle enclosure to prevent nozzle from freezing. 5.10. Insulation (CW only)

    5.10.1. Hydraulic cabinet insulation – rigid type rated to R4. 5.11. Hose Reel (CW only)

    5.11.1. Constant force spring driven hose reel mounted inside the heated hydraulic cabinet to store hose in heated area when not in use.

    5.12. Hose Retriever (WW only) 5.12.1. Hose hook standard 5.12.2. Internal spring driven cable retriever (optional)

    6. Frame and Panels

    1

  • Commercial DEF Bid Spec SP-7118A

    6.1. Frame 6.1.1. Hot dip 13 gauge G90 galvanized steel (0.093”) with welded corners for rigidity and added strength.

    6.2. Cosmetic panels - Hot dip G60 painted galvanized steel or stainless steel 6.2.1. Replaceable top and sides in black or stainless steel, with lower panels painted white or optional specified

    color. Stainless steel optional on WW only. 6.2.2. Lower panels locked to prevent tampering 6.2.3. Finish – High quality polyester powder coat over e-coat primer. Gas, oil, and UV resistant. 6.2.4. Stainless Steel (optional): Type 304 Kooline SSt with embossed brush finish.

    6.3. Nozzle Enclosure (CW only): 6.3.1. Enclosed heated nozzle storage with boot and operating mechanism.

    6.4. Bezel and Dialface Graphics 6.4.1. Bezel: High strength structural foam for improved rigidity painted black with one-piece clear polycarbonate

    window. Gas, oil and UV resistant. 6.4.2. Dialface: Back screened one-piece polycarbonate overlay (black print on white background per customer

    spec) with cutouts as needed for displays. Gas, oil and UV resistant. 6.4.3. Brand: Replaceable polycarbonate back screened brand panel. Gas, oil and UV resistant. Backlighted by

    fluorescent bulb (optional). 7. Unit of Measure (select one)

    7.1. US Gallons 7.2. Liters (“R”)

    8. Performance 8.1. Working pressure = 50 psi rated working pressure 8.2. Meter accuracy = +/- 0.25% 8.3. Flow Rating: 10 GPM (depending on pump and hanging hardware configuration) 8.4. Temperature Rating:

    8.4.1. Electronics: Ambient -30ºC (-22ºF) to +55ºC (+131ºF) 8.4.2. DEF Hydraulics (CW): Down to ambient -30ºC (-22ºF) 8.4.3. DEF Hydraulics (WW): Down to ambient -11ºC (+12ºF) – DEF freezes

    8.5. Relative Humidity: 20% to 95% non-condensing 9. Fluid Compatibility

    9.1. Suitable for use with Diesel Exhaust Fluid (DEF) that meets ISO-22241-1 purity standards. 10. Power Requirements - (select one)

    10.1. 115VAC/60Hz 11. System Interface (electronic type only - optional)

    11.1. Gasboy CFN RS485 interface for direct connection to control systems 11.2. Pulse Output. Selectable pulse/gallon outputs for Gasboy Series 1000, FleetKey and other fuel control systems.

    12. Inlet connection: 12.1. Standard: 1” BSPP male. 12.2. Location - CW: Bottom or Non-boot Side 12.3. Location – WW: Bottom, Boot Side, or Non-boot Side.

    13. Discharge: 13.1. Standard flow: 1” BSPP male fitting.

    14. Above Ground Tank Applications 14.1. Approved for AST applications.

    15. Regulatory Approvals 15.1. Safety: MET Laboratories Certification E212468 15.2. Weights & Measures: Meter accuracy meets requirements for retail custody transfer, sealable by local officials.

    15.2.1. National Conference of Weights & Measures certified (NTEP CoC 10-046) 15.2.2. Measurement Canada (MC) certified.

    15.3. FCC Part 15 Compliant 15.4. NYCFD approved

    16. Warranty 16.1. 12 month parts & labor standard

    17. Options 17.1. FRONT LOAD NOZZLE BOOT (“Z”): Relocates standard side-oriented nozzle boot to front of cabinet for lane-

    oriented fueling applications. Standard on CW model.

    2

  • Commercial DEF Bid Spec SP-7118A

    17.2. SLOWDOWN VALVE (“PP”): Reduces delivery to a slow flow for accurate preset shut-off by fuel control systems. Standard on all models.

    17.3. STAINLESS STEEL PANELS: Provide durable finish. Type 304 Kooline SSt with embossed brush finish. 17.3.1. CW Model: Stainless steel top and sides only ("SSTS"). 17.3.2. WW Model: All stainless steel panels ("SS"). Stainless steel front and back panels only ("SSA"). Stainless

    steel top and sides only ("SSTS"). 17.4. TopKAT PLUS MOUNTING KIT (“D5”) – Includes pump mounting hardware for the TopKAT PLUS fuel management

    system. 17.5. LIGHT (“L”): Illuminates products panels and register areas. Two fluorescent bulbs. Specify 115V or 230V. Not

    available with EK option. 17.6. SUBMERSIBLE PUMP DIRECT DRIVE RELAY: For the direct drive of submersible pumps up to 3/4 hp at 115VAC

    or 1-1/2 hp at 230 VAC. Rated 40 amps. Alternative to external relay box. Specify single or twin relays. 17.7. INTERNAL HOSE RETRACTOR (“I”) – WW Model Only: Keeps hoses out of the fueling lane. 17.8. CFN or TOPKAT RS485 - for direct connection to Gasboy control systems. 17.9. PULSE OUTPUT: Selectable pulse/gallon outputs for Gasboy Series 1000, FleetKey and other fuel control systems.

    (select one) 17.9.1. Single pulse output 17.9.2. Dual pulse output (single product single hose only)

    17.10. ELECTRO-MECHANICAL TOTALIZER (EMT): 7 digit non-resettable electro-mechanical totalizer. 17.11. HIGH HOSE RETRACTOR (“H”) – WW Model Only: Eases hose handling during fueling and keeps hose up and out

    of the way to reduce wear and run-over damage. High, post-mounted with enclosed spring return reel. 18. Accessories

    18.1. Hose 18.1.1. DEF Hose (1” BSPP x 11 foot) 18.1.2. DEF Hose (1” BSPP x 17.4 foot) – WW Model only

    18.2. Breakaway & Swivel: Combination SSt breakaway and swivel 18.3. Nozzle

    18.3.1. Standard nozzle 18.3.2. Nozzle with Misfueling Interlock

    19. Approved Suppliers 19.1. Electronic Fleet – Gasboy 9862KX

    3

    AT-P7067DAT-P7067D_34AT-P7072AT-P7073AT-P7065AT-P7068AAT-SP7177ABid Specification – Gasboy Atlas Electronic Fleet Products

    AT-SP7180ABid Specification – Gasboy Atlas Mechanical Fleet Products

    AT-SP7118ABid Specification Outline – Gasboy Atlas Commercial DEF Products