بسمه تعالی
description
Transcript of بسمه تعالی
تعالی بسمهFast Imaging of turbulent plasmas in the GyM
device
D.Iraji, D.Ricci, G.Granucci, S.Garavaglia, A.Cremona
IFP-CNR-Milan
7th Workshop on Fusion Data Processing Validation and Analysis
Frascati-March 2012
Outlines
• Motivations
• Fast imaging of GyM plasmas
• Reconstruction of the emissivity profiles
• Fluctuations profiles
• CAS for detection and visualization of plasma structures (a comparison with probe measurements)
• Summary
2
Motivations• Basic understanding of fluctuations and turbulence in magnetized plasmas
is an important issue for magnetic fusion, as they cause a high degree of particle and energy losses.
• A full spatio-temporal imaging system with reasonable resolution in time and space is needed to study plasma turbulence .
• A non perturbative approach is fast visible imaging of plasma turbulence. An ultimate goal of plasma imaging is extracting plasma turbulence characteristics from images.
• Fast imaging is often used in fusion devices however detailed comparisons with other diagnostics are needed for justification.
3
Fast Visible Imaging system
Camera Characteristics:
Photron ultima APX-RS
Full, 1024 by 1024 pixel resolution, up to 3,000 fps, 10-bit monochrome CMOS sensor with pixels in dimension of 17×17µm
Top recording speed is 250,000 fps
Image memory can be expanded to facilitate 6 second recordings at 1,000 fpsAnd 4.2 seconds at 250,000 fps.
Capability of synchronization with the Other diagnostics such as probes(error < 100nsec)
4
Fast visible plasma imaging
5
NSTX, S.Zweben CSDX, G.AntarTORPEX D.Iraji
•ELMs•Blobs/Filaments•Modes
High Speed gated Image Intensifier• Hamamatsu C10880-03
• Max. gain 10000
• Spectral response 185-900 nm
• Gating 10ns-10ms
• Repetition rate 200kHz
• Resolution 38 lp/mm
6
Langmuir probe
Hot filament source
2.45 GHz source
Modular device in which the magnetic field configuration can be easily modified.
# of Coils 10Max current 1000 AMax magnetic field 0.13 TCooling water rate 22 l/min Power supply (d.c.) 1000A/50V
Vacuum chamber (m):Length 2.11Diameter 0.25
GyM
Electron Temperature profileElectron density profile
B average ~ 80 mT
Line integrated images (raw data)H2, RF power: 1500 W
875000 fps, 4 us exposure time
I(t): Camera image frame at time t
Reconstruction of the emissivity profile
9
Zr
B
10
75000 fps, 4 us exposure time NR~ 0.05
Reconstructed emissivity profilesH2, RF power: 1500 W
Zr
B
g(t): Reconstructed emissivity profile at time t
I=T*g
T=U*S*V ,U*U =V*V = unitary
V*S *U *I=g
T
T-1
TT
Plasma structures in reconstructed profiles (fluctuations)
11
• Individual structures can be distinguished
• Structures appear rotate, merge and split after a while Z r
B
g(t)=g(t)-<g(t)>
Fluctuation profile of reconstructed emissivity at time t
~
Fluctuations
12
Maximum fluctuations level (MFL) PSD of the MFL signal
Fluctuations level
13
Fluctuations
r-Scan of PSDZ-Scan of PSD
Zr
B
Conditional Average Sampling (CAS)
E×B rotation and Te
14
V E×B ~ 1km/s, B~80 mT: E~80 V/m
L ~5.5cm, Te~ E L ~ 4.4 eV-1-1
Probe measurement
2 L = FWHM-1
E×B rotation and B
15
× .E×B is responsible for the rotation of the plasma column
E E
B B
Summary
The intensified fast camera is able to image plasma with spatial resolution of 2cm and temporal resolution of 4µs.
.Plasma emissivity profiles are reconstructed using pixel methode and singular value decomposition approach.
Fourier analysis of the reconstructed images show presence of a distinct mode at ~4 kHz which is radially extended between -3cm<r<2 cm and vertically located at the bottom.
CASed images show rotation of the structures associated with the mode due to E×B drift.
16
Outlooks
Structural analysis of the reconstructed emissivity profiles to estimate plasma transport.
The establishment of comparisons between the experimental plasma transport related to the plasma structures with theoretical predictions and confirmation using probe data.
17
Thank you
18