Assemblyimages.tigermedical.com/Assemblies/PRS341505...3 Post Pressure Fit System - User Guide Rev:...

15
3 Post Pressure Fit System - User Guide Rev: 2lst September, 2011 Page: 11 Caution: Before using the Pressure Fit System, the top plate, bottom plate, support- ing posts and adjustable track must be visually checked to ensure that there are no missing parts or unusual wear and tear. Top plate and Bottom plate should be cleaned and dried with wet cloth before installation ( See Cleaning Rubber Feet Instructions). Should anything look unusual contact your local dealer prior to use. Failure to comply with this caution could result in serious injury to the operator, the in- dividual being lifted and/or damage to the Pressure Fit and/or portable lift unit. Assembly Assembling the Support Posts Step 1 : Placed the bottom foot on the floor. Insert the bottom plate through the opening located at the bottom of the supporting post. Step 2 : Tilt the supporting post to the side to facilitate the installation of the top foot. Insert the top plate through the top opening of the supporting post. NOTE: Never install Top Foot at the Bottom section of Post NOTE: Never install Bottom Foot at the Top section of Post

Transcript of Assemblyimages.tigermedical.com/Assemblies/PRS341505...3 Post Pressure Fit System - User Guide Rev:...

Page 1: Assemblyimages.tigermedical.com/Assemblies/PRS341505...3 Post Pressure Fit System - User Guide Rev: 2lst September, 2011 Page: 18 Mounting the Adjustable Track with swivel trolley

3 Post Pressure Fit System - User Guide Rev: 2lst September, 2011 Page: 11

Caution: Before using the Pressure Fit System, the top plate, bottom plate, support-

ing posts and adjustable track must be visually checked to ensure that there are no

missing parts or unusual wear and tear. Top plate and Bottom plate should be cleaned

and dried with wet cloth before installation ( See Cleaning Rubber Feet Instructions).

Should anything look unusual contact your local dealer prior to use.

Failure to comply with this caution could result in serious injury to the operator, the in-

dividual being lifted and/or damage to the Pressure Fit and/or portable lift unit.

Assembly

Assembling the Support Posts

Step 1:

Placed the bottom foot on the floor. Insert the

bottom plate through the opening located at the

bottom of the supporting post.

Step 2:

Tilt the supporting post to the side to facilitate the

installation of the top foot. Insert the top plate

through the top opening of the supporting post.

NOTE:

Never install Top Foot

at the Bottom section of Post

NOTE:

Never install Bottom Foot at the

Top section of Post

Page 2: Assemblyimages.tigermedical.com/Assemblies/PRS341505...3 Post Pressure Fit System - User Guide Rev: 2lst September, 2011 Page: 18 Mounting the Adjustable Track with swivel trolley

3 Post Pressure Fit System - User Guide Rev: 2lst September, 2011 Page: 12

Assembly

Assembling the Support Posts (Continued)

Step 3a:

Press the red button down to release

the safety lock.

Step 3b:

Safety Lock Released.

Step 4b:

While pushing with two hands, the

lever will move out as shown in picture.

Note: Pushing

down the Post will

help in pulling out

the lever.

Step 4a:

Grab and Push down on the top section

of post with two hands as shown in

Picture.

Page 3: Assemblyimages.tigermedical.com/Assemblies/PRS341505...3 Post Pressure Fit System - User Guide Rev: 2lst September, 2011 Page: 18 Mounting the Adjustable Track with swivel trolley

3 Post Pressure Fit System - User Guide Rev: 2lst September, 2011 Page: 13

Assembly

Assembling the Support Posts (Continued)

Step 6:

Push the top section of post up towards the ceiling

with Top foot. Upon contact with the ceiling, con-

tinue pushing up until you hear one or two more

“clicks”.

Note:

At this point, the post should be exerting

pressure between the floor and ceiling.

Step 7:

Swing open post level. Please ensure the

level is fully open.

― CLICK‖

― CLICK‖

Step 5b:

Push the lever up to engage with the

magnet. NOTE: SEE MAGNET LABEL.

Step 5a:

Press in and hold the Ratchet

while pulling out the lever .

Keep Holding

the Ratchet

Page 4: Assemblyimages.tigermedical.com/Assemblies/PRS341505...3 Post Pressure Fit System - User Guide Rev: 2lst September, 2011 Page: 18 Mounting the Adjustable Track with swivel trolley

3 Post Pressure Fit System - User Guide Rev: 2lst September, 2011 Page: 14

Assembly

Assembling the Support Posts (Continued)

Step 8a:

Grasp bottom section of post, lift slightly and

adjust until bubble is centered and post is

perpendicular to floor and ceiling.

Step 8b:

Bubble centered.

Step 9a:

Push the lever down until it “clicks” into place.

Step 9b:

Push the lever in to secure it, until you hear a

click sound.

Note: Lever must rest in vertical position.

― CLICK‖

― CLICK‖

Page 5: Assemblyimages.tigermedical.com/Assemblies/PRS341505...3 Post Pressure Fit System - User Guide Rev: 2lst September, 2011 Page: 18 Mounting the Adjustable Track with swivel trolley

3 Post Pressure Fit System - User Guide Rev: 2lst September, 2011 Page: 15

Assembling the Support Posts (Continued)

Assembly

Step 10:

Ensure Pressure Gauge is in the Safe Zone.

Note: Green must be visible on both sides.

Step 11a:

Swing back the safety lock and level to the original

position.

Step 11b:

Safety Lock and Level must be firmly

Engaged in housing.

Step 12:

Install the second post repeating steps 1

though 11.

Note:

The distance between the two posts should

be between 7 to 10 feet.

Page 6: Assemblyimages.tigermedical.com/Assemblies/PRS341505...3 Post Pressure Fit System - User Guide Rev: 2lst September, 2011 Page: 18 Mounting the Adjustable Track with swivel trolley

3 Post Pressure Fit System - User Guide Rev: 2lst September, 2011 Page: 16

Mounting the Adjustable Track

Caution: Before installing the adjustable track , ensure lifting height is sufficient to

lift the patient. ( See Below different heights adjustment for all versions of Pressure

Fit System). Note: You need a Step Ladder to do this assembly. Ask for assistance if you

require help in installing the tracks.

Failure to comply with this caution could result in serious injury to the operator, the

individual being lifted and/or damage to the Pressure Fit and/or portable lift unit.

Working Heights for all versions of Pressure Fit System are as follow:

1) For 341500 - 2 Post Pressure Fit System— All 3 Hook Pins of both Post assemblies can be used for

the Adjustable Track to adjust the lifting height.

2) For 341505 – 3 Post Pressure Fit System— Only Top and Middle pin of 1st and 2nd Post Assembly

can be used for the Adjustable Track to adjust the lifting height, while Middle and bottom pin of 3rd

Post Assembly can be used to hook the Traverse/ Pivoting track.

3) For 341510 – 4 Post Pressure Fit System— All 3 Hook Pins of all 4 Post Assemblies can be used for

the Adjustable Track to adjust the lifting height.

Note: Drop in height per Hook pin is 6.360‖.

Top Pin

Middle Pin

Bottom Pin

Adjustable

Track

Traverse

Track

Page 7: Assemblyimages.tigermedical.com/Assemblies/PRS341505...3 Post Pressure Fit System - User Guide Rev: 2lst September, 2011 Page: 18 Mounting the Adjustable Track with swivel trolley

3 Post Pressure Fit System - User Guide Rev: 2lst September, 2011 Page: 17

MIN. 7 Feet MAX. 10 Feet

WIDE

MIN. 7 Feet MAX. 9 Feet

HEIGHT

MIN. 6 Feet MAX. 8 Feet

Traverse

Track

Adjustable

Track

3rd Post

Mounting the Adjustable Track

Caution: Before installing the adjustable track , ensure lifting height is sufficient to

lift the patient. ( See Below different heights adjustment for all versions of Pressure Fit

System). Note: You need a Step Ladder to do this assembly. Ask for assistance if you

require help in installing the tracks.

Failure to comply with this caution could result in serious injury to the operator, the

individual being lifted and/or damage to the Pressure Fit and/or portable lift unit.

Page 8: Assemblyimages.tigermedical.com/Assemblies/PRS341505...3 Post Pressure Fit System - User Guide Rev: 2lst September, 2011 Page: 18 Mounting the Adjustable Track with swivel trolley

3 Post Pressure Fit System - User Guide Rev: 2lst September, 2011 Page: 18

Mounting the Adjustable Track with swivel trolley

Note: You need a Step Ladder to do this assembly. Ask for assistance if you require help in installing the tracks.

Step 13a:

Hook one end of the track to post pin.

Step 13b:

Extend the track and hook to the other post.

Step 14a:

Attach the track end cap as shown above.

Step 14b:

Install the other end cap.

Note: Ensure track connector is sitting

properly on the spring pin as shown above.

Note: Don’t leave the track connector on

the spring pin as shown above.

Page 9: Assemblyimages.tigermedical.com/Assemblies/PRS341505...3 Post Pressure Fit System - User Guide Rev: 2lst September, 2011 Page: 18 Mounting the Adjustable Track with swivel trolley

3 Post Pressure Fit System - User Guide Rev: 2lst September, 2011 Page: 19

Completed Adjustable Track with swivel trolley

Note: Mount the adjustable track on the top pin only of

the Post .

Measure 8 feet from the

Post. Use measuring

tape.

Swivel

Trolley

Step 15:

Measure 7-8 feet from post to set up 3rd post.

Note: Max. Distance is 8 feet. Do not set up the 3rd post more than 8

feet distance.

Page 10: Assemblyimages.tigermedical.com/Assemblies/PRS341505...3 Post Pressure Fit System - User Guide Rev: 2lst September, 2011 Page: 18 Mounting the Adjustable Track with swivel trolley

3 Post Pressure Fit System - User Guide Rev: 2lst September, 2011 Page: 20

Step 16:

Install the 3rd post with 3 pin holes repeating steps 1 though 11.

Use the 3rd foot with white Plastic washer to install the 3rd post. Note:

The distance between the 3rd post and other 2 posts should be 7 to 8 feet.

Assembly— 3rd post

Foot with plastic

washer on it.

Page 11: Assemblyimages.tigermedical.com/Assemblies/PRS341505...3 Post Pressure Fit System - User Guide Rev: 2lst September, 2011 Page: 18 Mounting the Adjustable Track with swivel trolley

3 Post Pressure Fit System - User Guide Rev: 2lst September, 2011 Page: 21

Step 17:

Take Middle adjustable track with one hook

One hook on the

Middle adjustable

track.

Step 18:

Hook the track to the middle pin of the 3rd Post.

Step 19a:

Grab the other end of the track and slide into

the trolley.

Assembly— 3rd post and Middle adjustable track

Note: You need a Step Ladder to do this assembly.

Ask for assistance if you require help in installing the middle

track.

Middle Pin

Page 12: Assemblyimages.tigermedical.com/Assemblies/PRS341505...3 Post Pressure Fit System - User Guide Rev: 2lst September, 2011 Page: 18 Mounting the Adjustable Track with swivel trolley

3 Post Pressure Fit System - User Guide Rev: 2lst September, 2011 Page: 22

Assembly— 3rd post and Middle adjustable track

Step 19b:

Slide the track into the trolley until the Pin hits the Trolley

Pin Hits the trolley

Step 19c:

Put the finger into the Ring from underneath

the track and pull the Ring all the way down

Pull Ring Down

With Finger

Step 19d:

Ring should be pulled down all the way and

slide the track slightly until the pin is under

the trolley and Release the Ring.

Page 13: Assemblyimages.tigermedical.com/Assemblies/PRS341505...3 Post Pressure Fit System - User Guide Rev: 2lst September, 2011 Page: 18 Mounting the Adjustable Track with swivel trolley

3 Post Pressure Fit System - User Guide Rev: 2lst September, 2011 Page: 23

Assembly— 3rd post and Middle adjustable track

Step 20:

Slide the track through the trolley.

Step 21:

Slide the track until the pin is out as shown in

figure.

Completed Assembly

3 Post Pressure Fit System

Keep sliding

the track

Pin is out

Page 14: Assemblyimages.tigermedical.com/Assemblies/PRS341505...3 Post Pressure Fit System - User Guide Rev: 2lst September, 2011 Page: 18 Mounting the Adjustable Track with swivel trolley

3 Post Pressure Fit System - User Guide Rev: 2lst September, 2011 Page: 24

Assembly— 3rd post and Middle adjustable track

Step 23:

Repeat the same step for the other end also.

Make sure track goes all the way to the end.

Step 24: Bring the track to the middle and make sure track end is away from the wall .

Note: There must be enough room to move the middle track

smoothly. See requirements page.

Track end is away

from wall

Step 22:

Grab the middle track and slide the track to one

end as shown in figure.

Note: Make sure track goes

all the way to the end.

Note:

While moving the middle track there will be some resistance .

Slightly push to go all the way.

Note: Make sure track goes

all the way to the end.

Page 15: Assemblyimages.tigermedical.com/Assemblies/PRS341505...3 Post Pressure Fit System - User Guide Rev: 2lst September, 2011 Page: 18 Mounting the Adjustable Track with swivel trolley

3 Post Pressure Fit System - User Guide Rev: 2lst September, 2011 Page: 25

Final Inspection Prior to Use

Ensure Pressure Gauge is in the Safe

Zone.

Note: Green must be visible

on both sides.

Safety Lock and Level must be

firmly Engaged in housing.

End covers are installed properly