© 2014 IBM Corporation Rich McCarthy Partner Technical Advocate Power Systems [email protected]...
-
Upload
margaret-rodgers -
Category
Documents
-
view
213 -
download
0
Transcript of © 2014 IBM Corporation Rich McCarthy Partner Technical Advocate Power Systems [email protected]...
© 2014 IBM Corporation
Rich McCarthyPartner Technical AdvocatePower [email protected]
Power SystemsScale-outOct 2014 Announcements
2© 2014 International Business Machines Corporation
Agenda
POWER8 Scale-out Announcements
S824L & more IBM Flash Optimized NoSQL Offering Easy Tier 1.8-inch SSD Additional Scale-out News/Info
6© 2014 International Business Machines Corporation6
Power Systems
S822LPower Systems
S812L
Power Systems S822
1 & 2 Sockets
Power Systems S814
Power Systems S824
Power Systems
S824L
1-socket, 2UPOWER8 processorLinux onlyCAPI support (2)
2-socket, 2UPOWER8 processorUp to 24 cores1 TB memory9 PCI Gen3 slotLinux onlyCAPI support (4)PowerVM & PowerKVM
2-socket, 2UUp to 20 cores1 TB memory9 PCIe Gen 3AIX & LinuxCAPI support (4)PowerVM
1-socket, 4UUp to 8 cores512 GB memory7 PCIe Gen 3AIX, IBM i, LinuxCAPI support (2)PowerVM
2-socket, 4UUp to 24 cores1 TB memory11 PCIe Gen 3AIX, IBM i, LinuxCAPI support (4)PowerVM
2-socket, 4UUp to 24 coresLinuxNVIDIA GPUCAPI support(2)
NEWAnnounce
October 6th
6
Power Scale-out Servers
7© 2014 International Business Machines Corporation7
POWER S824L
Open Technology Platform for High Performance Analytics, Big Data, and Java Applications workloads
Incorporating the innovation of the OpenPOWER Community Partnership with NVIDIA
Accelerates by GPU Exploit the uncompromising performance
of proven POWER8 and NVIDIA GPU.
High Performance Analytics, Big Data, Java Application Workhorse Aim to deliver a new class of technology
that maximizes performance and efficiency for all types of technical compute and high performance analytics workloads as well as Java and Big Data Applications.
Plan Availability DateOctober 31st
7
8247-42L
© 2014 IBM Corporation8© 2014 International Business Machines Corporation 8
IBM and NVIDIA deliver new acceleration capabilities for Analytics, Big Data, and Java
Runs pattern extraction analytic workloads 8x faster
Provides new acceleration capability for analytics, big data, Java, and other technical computing workloads
Delivers faster results and lower energy costs by accelerating processor intensive applications
Power System S824L•Up to 24 POWER8 cores
•Up to 1 TB of memory
•Up to 2 NVIDIA K40 GPU Accelerators
•Ubuntu Linux running bare metal
9© 2014 International Business Machines Corporation9
Power System S824LProcessor
2x 10-core 3.42GHz or2x 12-core 3.02GHz
MemoryTotal 16 DDR3 CDIMM slots 16,32,64 GB CDIMM @ 1600 Mbps1TB capacity, 384GB/s bandwidth max
StorageJBOD, RAID 0,10,5,6
12 SFF Disk Drive, 1 DVD
LAN adapters 2x 10GBASE-T adapter or 2x 10Gb SFP+ Fiber SR plus 2x 1GE adapter
GPU adapter (1 min or 2 max)El Capitan nVidia K40 GPU adapter
Power supply 2+2 1400W PS
O/S Capable Linux Ubuntu 14.10
Hypervisor Capable OPAL, No virtualization
PCIe Gen3 Slots4 PCIe x16 G3 FHFL slots6 PCIe x8 G3 FHHL slotsCAPI capable on PCIe x16 slots
Native I/OUSB 3.0 (2 front, 2 rear) System Management 1GE (2 rear)System port (rear), USB 2.0 (2 rear)
9
11© 2014 International Business Machines Corporation11
POWER S824 More Memory
RPQ announce planned mid OctoberGA in DecemberRPQ Number 8A2232
No eConfig support – manual configLarger memory DIMM (128GB)
11
2X max memoryUp to 2 TB
Rules:a) No Mixing of DIMMs sizes. ( i.e when order 128GB DIMM, no other size ( 64GB, 32GB, 16GB ) can
be mixed with )b) Only qty 8 or qty 16 DIMMs ( no other qty accepted, so when order 128GB DIMM, customer can
either order them by quantity of 8 = 1TB or quantity of 16=2TB )c) No MES Upgrade provided for installed systems. d) Only supported on Models S824, no other Scale-out servers.
12© 2014 International Business Machines Corporation
NEBS: Differentiated Value for Telecommunications Clients
12
Designed for clients that require hardened infrastructures because of the industries they serve or data center environments where the equipment is located.Carrier-grade platforms for NGN infrastructure and application deployment, designed for extreme shock, vibration and thermal conditions which exceed normal datacenter design standards.Announcement Date: October 6 General available Date : October 31stEligible model : Power S822L and S822Certifications: NEBS Level-3 and ETSI
Optional DC power supply and flexible thermal settings Power Supply, 2x750 Watt, -48V DC, Hot-swap, Base and Redundant (#EB3H)
RPQ 8A2227 approval of configuration validation required Flexible Thermal Settings for NEBS Applications (#0709) For additional guidance,
visit: ibm.com/power/solutions/industry/telco or email [email protected]
13© 2014 International Business Machines Corporation
Agenda
POWER8 Scale-out Announcements
S824L & more IBM Flash Optimized NoSQL Offering Easy Tier 1.8-inch SSD Additional Scale-out News
14© 2014 International Business Machines Corporation14
Each PCIe G3 x16 full-height, full-length slots
now capable of CAPI
Power Systems
S822LPower Systems
S812L
Power Systems S822
1 & 2 Sockets
Power Systems S814
Power Systems S824
Power Systems
S824L
1-socket, 2UPOWER8 processorLinux onlyCAPI support (2)
2-socket, 2UPOWER8 processorUp to 24 cores1 TB memory9 PCI Gen3 slotLinux onlyCAPI support (4)PowerVM & PowerKVM
2-socket, 2UUp to 20 cores1 TB memory9 PCIe Gen 3AIX & LinuxCAPI support (4)PowerVM
1-socket, 4UUp to 8 cores512 GB memory7 PCIe Gen 3AIX, IBM i, LinuxCAPI support (2)PowerVM
2-socket, 4UUp to 24 cores1 TB memory11 PCIe Gen 3AIX, IBM i, LinuxCAPI support (4)PowerVM
2-socket, 4UUp to 24 coresLinuxNVIDIA GPUCAPI support(2)
14
Power Scale-out Servers
15© 2014 International Business Machines Corporation
POWER8
Coherence Bus
FPGA or ASIC
Customizable Hardware / Application Accelerator • Specific system SW, middleware, or user application• Written to durable interface
POWER8
PCIe Gen3Transport for encapsulated messages
POWER8 CAPI (Coherent Accelerator Processor Interface)
Was just Statement of direction in April 2014
10 June annc letter shared billing structure – feat #EC2A. EC2A is an enablement code to use with future separately acquired hardware.
Introducing hardware using CAPI October 2014
16© 2014 International Business Machines Corporation
Possible Example: CAPI Attached Flash Optimization
Issues Read/Write Commands from applications to eliminate 97% of instruction path length CAPI Flash controller Operates in User Space
Saves 10 Cores per 1M IOPs
Pin buffers, Translate, Map DMA, Start I/O
Application
LVM
Disk & Adapter DD
Read/WriteSyscall
strategy() iodone()
FileSystem
strategy() iodone()
Interrupt, unmap, unpin,Iodone scheduling
< 500Instructions
< 500Instructions
ApplicationPosix Async I/O Style API
User Library
Shared Memory Work Queue
aio_read()aio_write()
20K Instructions
20K Instructions
Attach flash memory to POWER8 via CAPI coherent Attach
17© 2014 International Business Machines Corporation
IBM Solution for Flash Optimized NoSQL - Power Systems Edition Significant Cost Savings for In-Memory NoSQL Data Stores
The Market: Explosive growth of new mobile, social apps requiring lightening fast response at high volume
Enabled by in-memory NoSQL, Key Value Stores like Redis
Ordered (key, value) pairs provide type of in-memory, lightening fast distributed hash table
Plays an important role in many large websites
GitHub, Amazon, Facebook, Twitter & more…
The Issue: x86 memory limited by max RAM
• Scale-out x86 servers limited memory size
• Results in costly, complex infrastructure
Load Balancer
500GB Cache Node
WWW
500GB Cache Node500GB Cache
Node500GB Cache Node1U x86 server (24)
512 GB memory
The POWER8 + CAPI Flash as RAM Advantage:• New FLASH as RAM for Redis in-memory apps• Provides means for large FLASH exploitation• Lower cost memory, greater workload density • Dramatically reduce costs to deliver services• Can be offered as a cloud-based service or as
an on-premise solution for enterprises
24:1 serverconsolidation3
24:1 serverconsolidation3
Up to 3x lower TCAUp to 3x lower TCA
24U
New
Power S822L/S812LUbuntu 14.10
FlashSystem 8402TB to 40 TB Flash
WWW
4U
The Solution: POWER8 + CAPI FLASH as RAM- Up to 40 TB in 4U
18© 2014 International Business Machines Corporation
Load Balancer
500GB Cache Node
10Gb Uplink
POWER8 Server
Flash Array w/ up to 40TB
Differentiated NoSQL(POWER8 + CAPI Flash)
New memory tier for POWER8 server Up to 40 TB for NoSQL based applications
Cluster solution in a box
Infrastructure Attributes- 192 threads in 4U Server drawer- 40 TB of memory based Flash per 4U Drawer- Shared Memory & Cache for dynamic tuning- Elimination of I/O and Network Overhead
Today’s NoSQL in memory (x86)
Infrastructure Requirements- Large Distributed (Scale out)- Large Memory per node- Networking Bandwidth Needs- Load Balancing
Power CAPI-attached Flash model for NoSQL regains infrastructure control and reigns in the cost to
deliver services.
What it Means to the Delivery of NoSQLs
WWW10Gb Uplink
WWW
Backup Nodes
500GB Cache Node500GB Cache Node500GB Cache Node512GB Cache Node
24:1 Reduction in infrastructure
2.4x Price reduction
12x Less Energy
12x Less rack space
40TB of extended memory
4U
22© 2014 International Business Machines Corporation
S822 / S824Easy Tier SSD Enhancement
23© 2014 International Business Machines Corporation
New Low-price 1.8-Inch SSD for System Unit Cage
Read intensive SSD -- Great performance, Great entry price Intelligent SAS controller in backplane places data with high read activity and low write activity on the drive to allow many years of service without replacement. (replacement covered by IBM service agreement)
For 2-socket server: S822 & S824Using high-function backplanewith Easy Tier function
Drive goes in 1.8-inch SSD cage
List price qty 3 177GB SSD for RAID-5T2 $ 3,930List price qty 3 387GB SSD for RAID-5T2 $10,764
Maintenance prices after warranty also about 60% less
63% lower
Prices are USA list prices and subject to change. Reseller prices can vary.
25© 2014 International Business Machines Corporation
4U Storage Backplane Options
Must select one
12 SFF SAS bays 1 SAS controllerNo write cache
RAID-0,1,5,6,10DVD bay
18 SFF SAS baysDual SAS controllers
7.2GB cacheRAID-0,1,5,6,10
DVD bayExternal SAS ports
8-bay SSD cage Easy Tier function
BaseExpandedFunction *
6+6 SFF SAS bays2 SAS controllers
No write cacheRAID-0,1,5,6,10
DVD bay
Split
4U server
Sweet SSD enhancement for AIX / Linux / VIOS S824 & S822 Using Easy Tier function
27© 2014 International Business Machines Corporation
Agenda
POWER8 Scale-out Announcements S824L & more IBM Flash Optimized NoSQL Offering (Bob Sullivan) Easy Tier 1.8-inch SSD Additional Scale-out News
29© 2014 International Business Machines Corporation
AC Power Supplies (single phase)
900W = #EB2L or #EL1A (Linux only)1400W = #EB2M or #EL1B (Linux only)
1-socket 4U (S814) uses 2 power suppliesif tower uses two 900W (100-120V or 200-240V)if rack uses two 1400W (200-240V)RPQ to use two 900W in rack for 100-120V option)
factory install only 4-core and 6-core, not 8-core
2-socket 4U S824 uses 4 900W power supplies 200-240V
S824L uses 4 1400W power supplies 200-240V
1-socket 2U uses 2 900W power supplies 200-240V
2-socket 2U uses 2 1400W power supplies 200-240V
NEWPlan announce
September 23rd
Through RPQ 8A2217
30© 2014 International Business Machines Corporation
No 4U Changing Rack to Tower or Vice Versa
1S 4US814
8286-41A
Choose Rack / Tower Tower Rack
Bezel for 12 SAS bay n/a #EJT8Bezel for 18 SAS bay n/a #EJT9Rail feature code n/a #EJTNFront Door & covers for 12 SAS bay #EJTG n/a
Front Door & covers for 18 SAS bay #EJTH n/a
Can NOT change S814 from rack-mount to tower or vice versa• Originally communicated as supported change, but further
analysis has found it not supportable. • Restriction due to a combination of factors. Labels with Power
ratings and certifications are impacted since tower and rack use different power supplies.
31© 2014 International Business Machines Corporation
Scale-out Servers & PCIe Gen3 I/O Drawer SOD
Oct 2014 SOD
IBM plans to extend the support of PCIe Gen3 I/O drawers to the POWER8 scale-out servers which have 6 or more cores. This drawer is planned to be attached via two x16 PCIe slots and will require an update to the currently available firmware.
IBM’s statements regarding its plans, directions, and intent are subject to change or withdrawal without notice at IBM’s sole discretion. Information regarding potential future products is intended to outline our general product direction and it should not be relied on in making a purchasing decision. The information mentioned regarding potential future products is not a commitment, promise, or legal obligation to deliver any material, code or functionality. Information about potential future products may not be incorporated into any contract. The development, release, and timing of any future features or functionality described for our products remains at our sole discretion.
32© 2014 International Business Machines Corporation
Scale-out Systems built with POWER8
• Portfolio is complemented by a full commitment to support an open stack of software
- Ubuntu, SUSE, RedHat, PowerKVM, and Open Stack
• New Capabilities (4Q2014)- 2 TB memory option in S824- Linux SUSE SLES12 (LE) enabling easier application portability- S824L w/ NVidia GPU acceleration- Mixed Endian VM support of a single PowerKVM host- NEBS option for Telco
S812L S822L S822 S814 S824L S8241-socket, 2ULinux only
2-socket, 2U Up to 24 cores 1 TB memory 9 PCI Gen3
slot Linux only PowerVM &
PowerKVMNEBs option
2-socket, 2U Up to 20 cores 1 TB memory 9 PCIe Gen 3 AIX & Linux PowerVMNEBs option
1-socket, 4U Up to 8 cores 512 GB
memory 7 PCIe Gen 3 AIX, IBM i,
Linux PowerVM 4 core/P05 for
IBM i
2-socket, 4U Up to 24 cores LinuxNVidia GPUAnnc/GA in
4Q14
2-socket, 4U Up to 24 cores 11 PCIe Gen 3 AIX, IBM i,
Linux PowerVM 1 TB memory2 TB memory
option