© 2010 HaB International Ltd© 2011 POWERbreathe International Ltd
© 2010 HaB International Ltd
POWERbreathe K-Series – The Product Range
K2 K3K1
Consumer Products Professional Healthcare
KH1
Non
-dow
nloa
dabl
eRe
al-ti
me
data
logg
ing
K4 K5 KH2
© 2011 POWERbreathe International Ltd
.
© 2010 HaB International Ltd
• POWERbreathe K-Series is a handheld electronic inspiratory muscle training device and is the third generation of POWERbreathe products
• It is used to generate a resistance to inhalation in order to train the muscles used to breathe (diaphragm and intercostal muscles)
• Variable resistance training is generated by a variable disk valve which moves up to 4000 times per second
• Resistance is controlled in response to measurements of pressure, flow and volume calculated up to 500 times a second
• The system allows training to be continuously and precisely controlled in response to different measurements
• Provides feedback and measurements on training progress and inspiratory muscle performance
What is the POWERbreathe K-Series?
© 2011 POWERbreathe International Ltd
© 2010 HaB International Ltd
Length Tension Relationship
Advanced Variable Resistance Training
Ten
sion
Length
Power Curve
The relationship between the length of a muscle and the contractile tension that it can exert
A muscle can usually exert its greatest contractile tension when it is at its resting length
At resting length has most active force
Typical length tension relationship
© 2011 POWERbreathe International Ltd
© 2010 HaB International Ltd
Tension
Length
Power Curve
Start point of the bicep muscle weakest point Full length.
Tension
Length
Power Curve
Mid way point of the bicep muscle at is strongest.
Tension
Length
Power Curve
End point of the bicep muscle weakest point. Shortest length
Advanced Variable Resistance Training
© 2011 POWERbreathe International Ltd
© 2010 HaB International Ltd
Start point of the breathing muscle strongest point when lungs are fully empty
Mid way point of the breathing muscle
End point of the breathing muscle weakest point
Tension
Length
Power Curve
Tension
Length
Power Curve
Tension
Length
Power Curve
Advanced Variable Resistance Training
© 2011 POWERbreathe International Ltd
© 2010 HaB International Ltd
The POWERbreathe K-Series creates a variable load which matches the length tension relationship of the inspiratory muscles allowing more effective training than conventional constant load training.
80% MIP
RVIVC(Inspiratory Vital Capacity)
RV(Residual Volume)
IVC
MIP
80% MIP
MIP
Advanced Variable Loading(POWERbreathe K-Series)
Conventional Constant Loading(POWERbreathe Classic/Plus)vs
Up to 50% more training work (area under graph) achievable at 80% intensity using variable load training
Up to 125% more air inhaled per breath at 80% intensity using variable load training
When constant loading is used, the breath must be stopped early as load
starts to exceed inspiratory muscle strength
Advanced Variable Resistance Training
© 2011 POWERbreathe International Ltd
POWERbreathe K-Series Main Features
© 2010 HaB International Ltd
Pacing Guidance
Session History
Multiple Training Protocols
Auto Setup
Single breath Test
© 2011 POWERbreathe International Ltd
Auto-optimising IMT
© 2010 HaB International Ltd
The POWERbreathe K-Series’ auto-optimising feature allows the device to automatically estimate the user’s ideal training resistance
PIF
MIPInspiratory Muscle Force-Velocity
Relationship
Flow
Pres
sure
During the first two breaths of a session, the maximum value of flow, and the pressure at which it is measured, is recorded.
Training resistance is extrapolated from the peak inspiratory flow using a typical inspiratory muscle force-velocity relationship.
Training intensity can be adjusted when in the automatic set-up mode in order to suit the user’s tolerance to exercise. Alternatively, training load can be entered manually.
© 2011 POWERbreathe International Ltd
Training Results
© 2010 HaB International Ltd
Training ResultsThe POWERbreathe K-Series provides performance feedback following every training session
Load is a measure of the resistance to inhalation during your training session – the equivalent to the weight lifted by the inspiratory muscles.
Volume is the average volume of air inhaled per breath.
Power is the average power generated during your entire training session and is a combined measure of the force exerted by the inspiratory muscles and the speed of contraction.
Mechanical work (effort ) of breathing for the session. combines the force exerted by your inspiratory muscles and the volume of air inhaled
Note: Feature only available for K4, K5, and KH2 model
© 2011 POWERbreathe International Ltd
Single breath Test
© 2010 HaB International Ltd
The Strength Index test can be used to quickly assess inspiratory muscle strength at any time. The test calculates inspiratory muscle strength based upon the peak inspiratory flow during a single test breath. The test results also show the peak flow and inhaled volume from the test breath. These results can be used to monitor the effects of inspiratory muscle training. S-Index value is rated (from v.poor to excellent) based upon predicted normal values calculated using the profile information (age, height, weight and gender).
PIF
MIP
Flow
Pres
sure
Note: Feature not available for K1 model
Inspiratory Muscle Force-Velocity Relationship
© 2011 POWERbreathe International Ltd
Single breath Test
© 2010 HaB International Ltd
S-Index Leader board
221 (UK)
202
197
195
183
165
138 (UK)
123
121
120
116
221cmH20
© 2011 POWERbreathe International Ltd
Customise Training
POWERbreathe K5 Features
New feature K4, K5 and KH2 only
BreatheLink Interface
Patient Relational Database
Pro-view Training
© 2011 POWERbreathe International Ltd
Interfaces with Breathe-Link software via a USB port
Real-Time live data sent 4000 times a second
Allowing analysis, processing and graphically representation of real time live data
Control the POWERbreathe unit via the PC
POWERbreathe K5
Breathe-Link Interface
© 2011 POWERbreathe International Ltd
Real time data acquisition analysis tool
Advanced graphical plot
High performance measurements of each individual breath
POWERbreathe K5
Pro-view training
© 2011 POWERbreathe International Ltd
Simplified View
Snapshot of vital information
POWERbreathe K5
Graphical view training
© 2011 POWERbreathe International Ltd
Customisable Load with BreatheLink (K5)
© 2010 HaB International Ltd
Customise load for individual breaths
Max number of breaths 60
Create your own training protocols
Using the Breathe-Link software to upload to
POWERbreathe K Series device
© 2011 POWERbreathe International Ltd
.
© 2010 HaB International Ltd
Professional Healthcare Products
© 2011 POWERbreathe International Ltd
© 2010 HaB International Ltd
POWERbreathe KH1 and KH2 Professional Healthcare Models
The POWERbreathe KH1 and KH2 are the next generation of inspiratory muscle training assessment tools for use by healthcare professionals including doctors, general practitioners, respiratory and cardiac specialists, surgeons, physiotherapists and nurses.
KH1 KH2
© 2011 POWERbreathe International Ltd
© 2010 HaB International Ltd
Antibacterial Filter AdapterThe POWERbreathe Kinetic KH1 and KH2 comes supplied with a filter adapter which enable use with TrySafe filters and other standard respiratory filters. This allows multi patient use of the same product whilst maintaining hygiene.
POWERbreathe Kinetic – KH1 Additional Features
Maximum Inspiratory Pressure TestThe widely accepted standard test for inspiratory muscle strength.
Patient inhales maximally against occluded valve from RV (Residual volume)The POWERbreathe Kinetic records the highest 1 second average pressure (50Hzsampling)No real census on how many breaths The maximum of three values that vary by less than 20% is recordedSee ATS/ERS Statement on Respiratory Muscle Testing
© 2011 POWERbreathe International Ltd
© 2010 HaB International Ltd
PC SoftwareIn addition to the KH1 features the KH2 will also feature pc connectivity via USB cable. PC software will include the following features:
POWERbreathe Kinetic – KH2 Additional Features
Patient relational database management systemReal-time data feedback Training customisation to suit patient groupsData will be in CVS format easily exported to Excel
© 2011 POWERbreathe International Ltd
© 2010 HaB International Ltd
POWERbreathe Kinetic KH1 and KH2 Healthcare Applications
As a standalone mouth pressure (MIP) meter for the
identification of respiratory muscle weakness
Identifying appropriate training levels for the
POWERbreathe Medic
Monitoring the outcomes of IMT
Familiarising the patient with the sensation of IMT
Training a patient within the clinic
Patient training in the home environment
As a research tool for investigating IMT efficacy
Potential Healthcare applications for the POWERbreathe Kinetic include:
© 2011 POWERbreathe International Ltd
© 2010 HaB International Ltd
POWERbreathe Kinetic – Basic Components
© 2011 POWERbreathe International Ltd