Post on 03-Jun-2015
description
Xpress Femoral
CompressionAssisted
Device
Is a vascular access site management
tool that combines a sterile dressing with active, hands-free pressure.
Should only be used for femoral Artery access site.
Xpress
Components
Components
Main Pad
Focus Pad
1.Easy to use
Simply apply and rotate the handle to desired pressure
Requires one operator and a standard luer-lock syringe
Minimal leaning curve Follows routine hospital protocol
Advantages
2. Adjustable hands-free
pressure Maintains consistent pressure on site during
patient recovery as well as patient positioning and transport Eliminates inconsistent operator dependent pressure
Excellent site management tool for irritable patients
Allows immediate pressure adjustments based on patient needs
Advantages
3. Integrated Clear
Window Facilitates proper placement Direct visualization of the site without
removing device Allows easy site assessment
Advantages
4. Mechanical
Pressure Provides an active mechanism to maintain
pressure, reducing demands on the staff
Advantages
5. Tegaderm
adhesive material Commonly used product that is tolerated well
by most patients Recognized as an effective adhesive that
maintains it’s position
Advantages
6. Enhance patient comfort
Flexible material comforts to patients anatomy Patient is not limited to supine position Allows for patient mobility Unlike other devices, no ancillary equipment or uncomfortable
straps are required
[ Typical recommendation ]For ordinary conditions
Stationary position for first 2 hours,Mobile condition for the next two hours
and removal of Xpress
Advantages
Diagnostic angiography Peripheral Neuro (4 vessel angio)
TACE (Transcather Arterial ChemoEmbolisation) Post VCD (AngioSeal, Perclos) application
To avoid potential complications
For primary Xpress application 4,5Fr and maximum 6Fr sheath Without anticoagulant procedure
(less than 3,000 units of Heparin)
Xpress is recommended for the femoral
hemostasis after …
Primary use after vascular intervention with
Anticoagulant (Heparin, Plavix, etc… ) Procedure with 7Fr of bigger size sheath Obesity patient with Body Mass Index (kg/m²)
over 40 Patient who has low blood platelet count
(less than 30,000/ µƖ )
Xpress is NOT recommended for …
Xpress Procedure
1. Cleaning the Skin Puncture Site
2. Palpation of vessel puncture site
2. Pull back procedural Sheath about 2.5cm from
puncture site
3. Locate Disk to Arterial Puncture site
4. Attach Xpress(Keep the pressure for
disk during attachment)
5. Rotate handle
6. Remove the Sheath
7. Assess the Puncture Site
through the Window
8. Transport
Provides consistent active pressure Pressure can easily be adjusted as
needed Site is clearly visible at all times Hands-free, saves valuable staffs’ time Enhances patient comfort and mobility Cost-effective
What Xpress can do for you!