Welcome Herzlich Willkommen Bienvenue JUMO SVS3000 according to data sheet 70.0755 Bernhard Müller.

Post on 29-Mar-2015

228 views 0 download

Tags:

Transcript of Welcome Herzlich Willkommen Bienvenue JUMO SVS3000 according to data sheet 70.0755 Bernhard Müller.

WelcomeHerzlich WillkommenBienvenue

JUMO SVS3000JUMO SVS3000

according to data sheet 70.0755

Bernhard Müller

2Produktbereich / © JUMO

For measurement, control, recording and visualization.

At any time, at any place.

3Produktbereich / © JUMO

Central visualization and operation

Continuous batch documentation

Remote alarm

Realization:

Existing visualization objects – drawing is not necessary

Finished connection to JUMO process devices – only

addressing and selection of function

Individual customer solutions – on demand

Visualization software SVS3000

Application:

4Produktbereich / © JUMO

Functionality structure of SVS3000

• Operates with predefined, animated, graphic objects

• Is based on the visualization software PCVUE32

• Free extension by PCVUE32 development environment

PCVUE application SVS3000 application

Operating system

Basis software

Planning of PCVUEPlanning of PCVUESuperposed

application tool

Finished application

Configuration,parameterization

5Produktbereich / © JUMO

System requirements

• Operating system: Windows XP

Attention: Service pack 2!!

• Pentium processor

• min. 512 MB RAM

• min. 750 MB free hard disk storage

• Graphic resolution 1024*768 or 1280*1024

• Internet Explorer version 5.1 or higher

• Operates under user rights in Windows

Remark: Sampling rate for each interface and device about 0,5…1,5 sec.

6Produktbereich / © JUMO

Start screen SVS3000

With menu bar and alarm list

7Produktbereich / © JUMO

Flow diagram as an option, specific to application

8Produktbereich / © JUMO

SVS3000 layout of a group chart

VIS object

Toolbar

Directbuttons

Alarm list

Smalltrend chart

9Produktbereich / © JUMO

SVS3000 alarm list in the group chart

Only the active and unacknowledged alarms of the assigned plant were displayed in the alarm list of the group chart.

10Produktbereich / © JUMO

Big trend chart

- Different zoom functions- Cursor function- Indicated time-period can be selected- Shown/not shown of curves - Shown/not shown of scale- Legend relocateable

11Produktbereich / © JUMO

• Group mimics

• Trends

• Alarms

• Events

• Application mimics• Recipes

Application Explorer

The new application explorer – direct selection of mimics:

12Produktbereich / © JUMO

Direct buttons

Direct skip into selected group and flow charts via direct buttons.

13Produktbereich / © JUMO

Event list

Different events can be displayed for each plant:

-Alarms

-Acknowledgements

-Log in / log out ofusers

-Binary states

-Sending of setpoints

-Start/Stop of PGMs

14Produktbereich / © JUMO

Alarm list

Different alarms can be displayed for each plant or overview:

- Active and unacknowledged

- Active and acknowledged

- Inactive and unacknowledged

- Inactive and acknowledged

- Invalid alarms

15Produktbereich / © JUMO

SVS3000 menu bar with toolbar

Open recipe send list Select and send recipes Log in / log out of users

Hardcopy of screen Open report evaluation Open event lists

Open alarm lists Open application explorer Home icon – software switches into a defined start screen – group mimic, application mimic

Company Free hard disc storage Name Active Logged in System date name capacity of the open mimic alarms user / time

The icons for opening the parameter-and configuration-level still appear after log in.

Furthermore the user is now also able to minimize the SVS3000.

16Produktbereich / © JUMO

New controller item

Switching the cursor or

manual entry

Setting of setpoint by:

17Produktbereich / © JUMO

Batch reporting

As standard a batch report function is available in the SVS3000 to enable the tracing of certain production batches.

Important in this connection:• How are the batches started and stopped:

1. Manually via PC

2. Automatically by program signal in the program controller

3. Automatically by operation signal – via binary input

• Furthermore it has to be clarified how the batch data (e.g. batch number, customer, user,…) were entered:

1. Manual entry on PC

2. Scanning by barcode reader

3. Automatic generation of a serial batch number

18Produktbereich / © JUMO

• Data recordingTrend, events, manual accompanying text, batch data

• Searching of reports Search for: date, time and 3 batch data, names can be edit

• Print data Diagram or list, comment, event – selection of data

• Data export Into ASCII format, selection of data, to evaluate the measuring

data e.g. in Excel

Batch reporting for 50 (100) plants

19Produktbereich / © JUMO

Example for manual entry of batchdata

• Entry of batch data (manually or by list)

• Manual start and stop of batch reporting via buttons

20Produktbereich / © JUMO

Report search template

Here the user enters e.g. batch number, customer number, product name for which reports he is searching e.g. program 55.

Predefined data canbe selected with theselector buttons.

21Produktbereich / © JUMO

Report search template

In this case the SVS3000 shows that the program 55 was running on 25th September 2007 from:13.46:57 to 16:47:32Here the user can inspect, print and export the trend curve progression and alarms, events as well as comments of this batch.

22Produktbereich / © JUMO

ASCII converted report in Excel

23Produktbereich / © JUMO

Tabular valuesTabular values

SVS3000 batch printout

Alarm / event listAlarm / event listTrend chartTrend chart

24Produktbereich / © JUMO

Recipe functionThese function allow the user to store and simultaneously transfer different setpoints to different devices.

Example extruder

300 320 340310

Recipe 12345

25Produktbereich / © JUMO

Recipe function

Example:1 Imago 500 with4 controllers:Recipe for item 101

26Produktbereich / © JUMO

Recipe function

Example:1 Imago 500 with4 controllers:Recipe for item 102

27Produktbereich / © JUMO

General data overviewData summaryof all plants

Plant specific data overviewData summary of one plant :

Plant 1

- Group mimic- Trends- Events - Alarms- Reports- Recipes

Plant 2

- Group mimic- Trends- Events - Alarms- Reports- Recipes

Plant 3

- Group mimic- Trends- Events - Alarms- Reports- Recipes

Plant 1-3•General group chart

Philosophy of the 50 (100) plants

Plant 1 Plant 2 Plant 3

28Produktbereich / © JUMO

Backup every day at a

defined time

• Fixed file size

Memory management of a plant

Concept of data storage

Process data

Plant 11MB234...

50MB

Process data

Plant 1

Local:C:\ProjectSVS3000\SVS_Save

• Variable file size

Process data

Plant 1

Free file path:X:\..........

These data are not deletedby SVS3000!

Archive on hard disc C:\ProjectSVS3000\USR\Svswork\TH

1.

2.

29Produktbereich / © JUMO

• Setting of PC stations

• Entry of used interfaces

• Entry of connected devices

• Selection of the required device functions

• Entry of plant data: measurement ranges, alarm limits,...

• Configuration of reports

• Free entry of math formulae

Configuration level

30Produktbereich / © JUMO

Configuration SVS3000

Entry company nameApplication namePassword managementFormulae list

Definition PC stations…(see next page)

Exit configuration level

Storage of config. data in a file

Storage of a new configuration

Configuration overview

31Produktbereich / © JUMO

Definition of reports- Definition interfaces- Definition connected devices- Definition device functions and variables (measurement range, limit value, name,…)

Definition of the plant

Selection of background images

Configuration SVS3000

32Produktbereich / © JUMO

Setting of storage cycle for each variable

global percental input of storage hysteresis relating to the measurement range

also individual percental for every input of storage hysteresis relating to the measurement range

optimized to the process data which have to be recorded

optimally use of the memory

33Produktbereich / © JUMO

Configuration SVS3000

Setting of users

Definition of the global dead band in % on the analog processvalues regarding the selected measurement range.

34Produktbereich / © JUMO

Individual hysteresis for each variable

In this example:0,1 % of 18…38 °Crepresents a resolution of 0,02 °C in display and documentation

35Produktbereich / © JUMO

SVS3000 – periodical reports

for daily, weekly and monthly reports

36Produktbereich / © JUMO

Integrated Modbus TCP/IP driver unit

For easy connection of JUMO field devices

e.g. paperless recorderJUMO LOGOSCREEN nt

37Produktbereich / © JUMO

Parameter level

• Definition of the trends

• Definition of the group mimic`s

• Definition of the recipes

• Definition of the timetables

38Produktbereich / © JUMO

SVS3000 - Assistant (Wizzard) for trend and group charts

39Produktbereich / © JUMO

SVS3000 update possibility, prices

Update tool is planned to beimplemented in SVS3000 fromversion 2 on.

Good ByeAuf WiedersehenAu revoir

JUMO GmbH & Co. KG