ACT 7.0 TEST PLAN

PRC No.: 196549

Client: ACT

PRC Priority: AAA

Move ASAP? N

Object Name(s): prc_before_ins.trg

Problem Description: WEB PRC SYSTEM IS CREATING THE NEW PRC'S AS WORK TYPE FX-FIX. PLEASE MODIFY TO SET THE WORK TYPE FROM GLOBAL CODESET PRC_SYSTEM_DEFAULT_WORK_TYPE.

IF PRC_SYSTEM_DEFAULT_WORK_TYPE IS SET TO WORD NULL, THEN LEAVE THE WORK TYPE BLANK.

NEW GLOBAL CODESET HAVE BEEN ADDED ON PRC 196486.

Developer Notes:

PLEASE WORK ON THIS PRC

Test Plan: Set the global codeset PRC_SYSTEM_DEFAULT_WORK_TYPE to null. Then, via the PRC web interface, enter a new PRC. Verify in the PRC system that the ‘Work Type’ is blank on the PRC. Then, change the global codeset to ‘DX’ and verify that when another new PRC is entered, the work type is defaulted to ‘Data Fix’.

Verify global codeset PRC_SYSTEM_DEFAULT_WORK_TYPE set to null

Open test PRC website, enter a new PRC

Now go to PRC system, bring up PRC and view Work Type

Work Type is blank, as expected.

Now change global codeset to ‘DX’

Enter new PRC

Now check PRC system for work type

Work type is Data Fix, as expected. Passed.