VRV indoor units combine with residential indoor units, all in one system
PCV1131
11
Meet the new single outdoor unit series, connectable to both VRV and residential indoor units
First launched in Japan in 1982, the Daikin VRV system has been embraced by world markets for nearly 30 years. Now, Daikin proudly introduces the new VRVIII single outdoor unit series which enables a mixed combination of VRV indoor units and residential indoor units all in one system, opening the door to stylish and quiet indoor units.
2
HOMES
OFFICES
SHOPS
Contents
Main Features................................page 3
Control Systems...........................page 39
Indoor Unit Lineup.........................page 9
Outdoor Unit Lineup......................page 4
Specifications...............................page 24
Indoor units.............................page 24
Outdoor units...........................page 34
• V R V.....................................page 9• Residential............ ........ ....page 19
• V R V.....................................page 35• Residential............ .......... ....page 37
• V R V.....................................page 24• Residential............ .......... ....page 31
BP units.......... ................. ........page 33
Option List....................................page 35
Indoor units.............................page 35
Outdoor units...........................page 38
BP units.......... ................ .........page 38
Wide range of choices
Main Features
3
VRV indoor units 15 types 73 models
VRV indoor units
Ceiling MountedCassette (Round Flow)
Type Model Name Capacity Range
Capacity Index 20
0.8 HP
40
1.6 HP
62.5
2.5 HP
80
3.2 HP
100
4 HP
125
5 HP
140
6 HP
200
8 HP
250
10 HP
50
2 HP
31.25
1.25 HP
25
1 HP
20 40 63 80 100 125 140 200 250503225
Ceiling Mounted Cassette(Double Flow)
FXCQ-MVE
Ceiling MountedCassette (Compact Multi Flow)
FXZQ-MVE
Slim CeilingMounted Duct
Ceiling MountedDuct
Ceiling Suspended
Wall Mounted
Floor Standing
ConcealedFloor Standing
Ceiling MountedCassette Corner
FXDQ-NBVE(with drain pump)
FXDQ-NBVET(without drain pump)
FXMQ-PVE
FXMQ-MAVE
FXHQ-MAVE
FXAQ-MAVE
FXLQ-MAVE
FXNQ-MAVE
FXKQ-MAVE
FXDQ-PBVET(without drain pump)
FXDQ-PBVE(with drain pump)
(900/1,100 mm width type)
(700 mm width type)
R-410A VRV system indoor units are not compatible with the R-22 VRV system.Note:
Note:
VRV indoor units connection unit series
Ceiling Suspended Cassette
Type Model Name
FXUQ-MAV1
BEVQ125MAVE
5 HP
BEVQ100MAVEBEVQ71MAVE
4 HP3 HP
12510071
Capacity Range
12510071
Connection Unit
Capacity Index
FXFQ-PVE
Indoor unitsIndoor units can be selected from 2 lineups, both VRV and residential indoor units, to match rooms and preferences.
BEV units are necessary for Connection unit series indoor units. Refer to the Engineering Data Book for details.Note:
Connection unit
Wall Mounted
Slim CeilingMounted Duct
Ceiling MountedCassette (Compact Multi Flow)
Type Model Name Rated Capacity 2.5 kW 6.0 kW 7.1 kW5.0 kW3.5 kW
Capacity Index 29 68 795540
25 60 715035
FFQ-BV1B
FDKS-EAVMB
FDKS-C(A)VMB
Ceiling Mounted Cassette FCQ-BVE
Ceiling MountedBuilt-in FBQ-BV1
FTKS-DVM
FTKS-FVM
(700 mm width type)
(900/1,100 mm width type)
4
Residential indoor units with connection to BP units 7 types 21 models
Outdoor units
8, 10 HP 12, 14, 16, 18 HP
The new VRVIII single outdoor unit series offers 6 models to select from, providing the power that suits your needs.
Model Name
CapacityRange
Capacity Index
RSXQ8PY1 RSXQ10PY1 RSXQ12PY1 RSXQ14PY1
8 HP 10 HP 12 HP
200 250 300
Outdoor unit lineup
RSXQ16PY1 RSXQ18PY1
16 HP 18 HP
22.4 kW
HP
kW 28.0 kW 33.5 kW
14 HP
350
40.0 kW 45.0 kW 49.0 kW
400 450
Residential indoor units
BP units are necessary for residential indoor units. Refer to page 33 for BP unit details.Note:
BP unit BP unit
single outdoor unit series
Energy efficiency and quiet operation
Main Features
5
Nighttime quiet operation function
Set on the outdoor PCB. Time of maximum temperature is memorised. The low operating mode will initiate 8 hours*1 after the peak temperature in the daytime, and normal operation will resume 10 hours*2 after that. The operation sound level for the night mode can be selected from 55 dB(A) (Step 1),50 dB(A) (Step 2) and 45 dB(A) (Step 3).
Automatic mode
Operation sound level selectable from 3 steps for the night mode
Mode 1.
Automatic modeMode 1.
Starting time and ending time can be input. (An external control adaptor for outdoor unit, DTA104A53/61/62, and a locally obtained timer are necessary.)
Manual modeMode 2.
Combinations of modes 1 and 2 can be used depending on your needs.
Combined modeMode 3.
*1. Initial setting. Can be selected from 6, 8 and 10 hours.*2. Initial setting. Can be selected from 8, 9 and 10 hours.
High COPsIt has become essential for air conditioning manufacturers to develop systems that provide high energy savings. We at Daikin have made great efforts in this field, and the VRVIII delivers highly efficient performance, contributing to high energy savings.
We have reached a high level of efficiency, thanks to advanced features such as the heat exchanger, the grille and the dual DC fans.
Achieving a high COP
• Cooling operating conditions: Indoor temp. of 27°CDB, 19.0 °CWB, and outdoor temp. of 35°CDB.
1
8 HP 10 HP 12 HP
2
3
4
4.27
3.54 3.75
Outdoor units use Daikin’s unique scroll compressor to realise energy saving performance and quiet operation.
• This function is available in setting at site.
• The relationship of outdoor temperature (load) and time shown in the graph is just an example.
The capacity reduction rate differs depending on the operation sound level step selected.
Notes:
Peak in outdoor temperature (For 10 HP outdoor unit)
Cap
acity
%
8 hrs 10 hrs
Ope
ratio
n so
und
dB(A
)
50
8:00 12:00 16:00 20:00 0:00 4:00 8:00
50
100
5855
0
Load
%
Night mode Night mode endsendsNight mode Night mode startsstarts Night mode endsNight mode starts
Night Mode
45
(Initial setting)(Initial setting)
Step 2 max. - 8dB(A)
Step 1 max. - 3dB(A)
Step 3 max. - 13dB(A)
Step 2: 50 dB(A)
Step 1: 55 dB(A)
Step 3: 45 dB(A)
A collection of cutting-edge technologiesrealises efficient and quiet operation
1
5 DC fan motor
3 Compact aero box
Realises a compact casing by stacking the Inverter and control PCBs plus optimising the internal design to suit airflow speed. This achieves low noise and reduces the power required by the large-diameter fanned outdoor unit.
• Efficiency improvement by approximately 40% especially at low speed.
4 Smooth sine wave DC Inverter
By adoption of the Sine Wave, which smoothes the rotation of the motor, operation efficiency is improved sharply. DC fan motor
structure
ReluctanceDC motor
High efficiency compressor
Reluctance DC scroll compressorDaikin’s unique scroll compressor reduces heat loss, and is driven by a high efficiency motor to achieve significant energy savings.
By introducing high pressure oil, the reactive force from the fixed scroll is added to the internal force, thereby reducing thrust losses. This results in improved efficiency and suppressed sound levels.
High-performance, low-noise scroll compressor operates at a fast rate. The speed increase has been achieved through advanced stress analysis for increased strength and utilisation of the advantages (oil film control) of the high thrust mechanism.*
*High thrust mechanism
200 300 400 500 600 700 800 900 1000
0
20
40
80
60
100
Eff
icie
ncy
(%
)
Motor speed (rpm)
AC motorAC motorAC motorAC motorAC motor
DC motor efficiency (comparison with AC motor)
Approx.Approx.
40%40%increaseincrease
Approx.
40%increase
DC motorDC motorDC motorDC motorDC motor
High torque and efficiency is attained with the adoption ofneodymium magnets.
Neodymium magnets are well known for their powerfulness compared to commonly used ferrite magnets.
Use of neodymium magnets in the motor enables efficient generation of high torque.
Powerful magnets
Note: Data are based on studies conducted under controlled conditions at a Daikin laboratory.
Thanks to an optimised e-Pass heat exchanger, heat change effectiveness has been increased, thus contributing to a high COP.
2 Heat exchanger
6
2 4
3
1
5
Design flexibility
Main Features
Long piping length offers flexibility during installation.
When only VRV indoor units are connected
When only VRV indoor units are connected
Maximum allowablelevel difference
Maximum allowablepiping length
Maximum allowablepiping length
Minimum allowable piping length
Between the outdoor unitand the indoor unit
Between the indoor units
Between the first indoor branch and the farthest indoor unit
Total piping length
Refrigerant piping length
15 m
—
—
j
a+b+c+d+e+f+g+h+i
a+b+c+d+i
b+c+d+i
100 m 125 m
250 m
40 m
Actualpiping length
Equivalentpiping length Example
Level Difference Example
50 m kIf the outdoor unit is above.
If the outdoor unit is below. 40 m k
When a mixed combination of VRV and residential indoor units is connectedor when only residential indoor units are connected
Maximum allowablelevel difference Between the outdoor unit
and the indoor unit
Between BP unitand indoor unit
Between the indoor units
Between BP units
Between the first indoor branch and the farthest BP unit orbetween the first indoor branch and the farthest VRV indoor unit
Total piping length
Refrigerant piping length
Between outdoor unit and the first indoor branch
15 m
15 m
l
m
n
n
o
a+b+c+d+e+f+g+h+i+j+k
b+c+g, b+c+d
a+b+c+g+k, a+b+c+d
h, i, j, k
a
100 m
250 m
2 m–15 m
2 m–12 m
2 m–8 m
50 m*1
5 m
Actualpiping length Example
Level Difference Example
50 mIf the outdoor unit is above.
If the outdoor unit is below.
If indoor unit capacity index < 68.
If indoor unit capacity index is 68.
If indoor unit capacity index is 79.
40 m
40 m
Long piping length
*1. When the piping length exceeds 20 m, the size of the main pipes (the gas side and the liquid side) must be increased. Please refer to Engineering Data Book for details.
Max.
50 m
Max.
15 m
Max.
50 m
Max.
40 mMax.
15 m
Max.
15 m
Actual piping length
Max. 100 m
Total piping length
Max. 250 m
a
o
l
n
dcb
gfeFirst indoor branch
mh i
a
i
j
k
dcb
hgfeFirst indoor branch
Colours in the diagram below are merely for identifyingpipes referenced with symbols such as a .
Colours in the diagram below are merely for identifyingpipes referenced with symbols such as a .
VRV: VRV indoor unitRA: Residential indoor unitBP: BP unit
When a mixed combination of VRV andresidential indoor units is connected
j
k
Between the outdoor unit and the BP unit
BP
RA RA
RA
RA
VRV
VRV
BP
7
Easy Installation High reliability
High external static pressure of 78.4 PaHigh external static pressure has been achieved thanks to the fan grilles and the dual DC fans that reduce internal pressure loss. Daikin offers 78.4 Pa (8 mm H2O) external static pressure by field setting to meet the requirements for installation on each floor.
VRVIII single outdoor unit series enables a mixed combination of VRV and residential indoor units by connecting BP units. As many as 29 indoor units can be connected, making this series a highly versatile system.
78.4 Pa
Small and light, significantly reducingconstraints during carry-inCarry-in possible using ordinary elevators
Can be carried on a fork-lift without a pallet
Easy belt suspension
Automatic test operationSimply press the test operation button and the unit performs an automatic system check, including wiring, shutoff valves, and sensors. The results are returned automatically after the check finishes.
Backup operationIf one of the multiple compressors malfunctions, the other compressors take over for emergency operation.*1
Less chances of refrigerant leakageThe shutoff valve connections for outdoor unit are brazed, meaning less chance of refrigerant leakage compared with flanged or flared connections.
*1. Possible only with single outdoor unit systems that are equipped with two or more compressors. Local setting of the outdoor unit is necessary.
If one compressor malfunctions...
Emergency operation occurs.*1
Note: Total capacity index of connectable indoor units must be 50%–130% of the capacity index of the outdoor unit. Refer to page 34 for the maximum number of connectable indoor units.
Indoorunits29
Max.
8
As many as 29 indoor units can be connected
VRV indoor units
Residential indoor units
BP unit BP unit
9
360° airflow improves temperature distributionand offers a comfortable living environment.
FXFQ25P/FXFQ32P/FXFQ40P
FXFQ50P/FXFQ63P/FXFQ80P
FXFQ100P/FXFQ125P
Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing member (option) must be used to close each unused outlet.
3-way flow L-shaped 2-way flowAll-round flow 4-way flow
850 mm
The industry’s first* Round Flow Ceiling Mounted Cassette type offers 360° airflow with improved temperature distribution.
All models are lighter than the conventional ones.Ex: Models FXFQ25P-50P are 4.5 kg lighter (reduced from 24 kg to 19.5 kg).
A modern sophisticated decoration panel has been applied, with a panel surface that has been treated with a dirt-repellant coating.
An antibacterial treatment that uses silver ions has been applied to the drain pan, preventing the growth of slime, mould and bacteria that cause blockages and odours.
The horizontal louvres prevent dew condensation. Their non-flocking surfaces, which repel dirt, are easy to clean.
The air filter has an anti-mould and antibacterial treatment that prevents the growth of mould generated from dust or moisture that may adhere to the filter.
Example of airflow patterns:360° airflow is available, as well as 2- to 4-way flows, so you can choose the most suitable airflow pattern depending on location or room layout.
Drain pump is equipped as standard accessory, and the lift height has been improved from 750 mm to 850 mm.
Treated surface Untreated surface
Resists soiling
• Condition after exposure to the smoke of 600 cigarettes in 1 m3 enclosed space.
Dirt andgrime
Control of the airflow rate has been improved from 2-step to 3-step control.
4-way flow Round Flow
There are areas of uneven temperature.
There are much fewerareas of uneven temperature.
* As of April 2004, the release date for Japan.
Indoor Unit Lineup
Low operation sound level (dB(A))
44/39/34
125
43/37.5/32
100
36/33.5/31
80
34/31/28
63
32/29.5/27
50
31/29/27
4025/32
30/28.5/27Soundlevel
(HH/H/L)
FXFQ-P
VRV Indoor Units
Ceiling Mounted Cassette (Round Flow) Type
* Remote controllers are an optional accessory. Refer to page 39 for remote controller details.
10
Quiet, compact, and designed for user comfort
Dimensions correspond with 600 mm X 600 mm architectural module ceiling design specifications.
Wide discharge angle: 0° to 60°
2-, 3-, and 4-way airflow patterns are available, enabling installation in the corner of a room.
Comfortable airflow
Low operation sound level(dB(A))
0°
60°
0°
60°
Auto swing Fixed angles: 5 levels
Angles can be also set on site to prevent drafts (0°-35°) or soiling of the ceiling (25°-60°), other than standard setting (0°-60°).
For 3-way or 2-way flow installation, the sealing member for air dischargeoutlet (option) must be used to close each unused outlet.
30/25
20/25 32 40 50
32/26 36/28 41/33
32/26 34/28 37/29 42/35
FXZQ-M
750 mm
Drain pump is equipped as standard accessory with 750 mm lift.
4-way flow 3-way flowL-shaped
2-way flow
1
2
0° 0°
60° 60°
FXZQ20M/FXZQ25M/FXZQ32M
FXZQ40M/FXZQ50M
230 V
240 V
Sound level (H/L)
Ceiling Mounted Cassette (Compact Multi Flow) Type
* Remote controllers are an optional accessory. Refer to page 39 for remote controller details.
11
Thin, lightweight, and easy to install in narrow ceiling spaces
FXCQ-M 20
32/27
25/32
34/28
63
37/32
40/50
34/29
80
39/34
125
44/38
34/29 36/30 39/3437/32 41/36 46/40
(dB(A))
305 mm
The thin unit (only 305 mm high) can be installed in a ceiling space as narrow as 350 mm. All models feature a compact design with a depth of only 600 mm.
(When a high-efficiency filter is attached, the unit's height is 400 mm.)
Low operation sound level
Designed with higher airflow suitable for high ceiling application up to 3 metres.
Providing 2 different settings of standard and ceiling soiling prevention, the auto swing mechanism realises even distribution of airflow and room temperature.
Two types of optional high-efficiency filter are available (65% and 95%, colourimetric method).
A long-life filter (maintenance free up to one year*) is equipped as standard accessory.
Drain pump is equipped as standard accessory with 600 mm lift.
Major maintenance work can be performed by removing the panel. A flat-type suction grille and a detachable blade make cleaning easy.
220 V
240 V
Sound level (H/L)
600 mm
600 mm
Indoor Unit Lineup
VRV Indoor Units
Ceiling Mounted Cassette (Double Flow) Type
FXCQ20M/FXCQ25M/FXCQ32M
FXCQ40M/FXCQ50M/FXCQ63M
FXCQ80M/FXCQ125M
* Remote controllers are an optional accessory. Refer to page 39 for remote controller details.
* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3
12
Slim design for flexible installation
Main body
Air discharge grille (Option)
Set for front discharge using a suspended ceiling.
Downward discharge is shut off and air is blown straight out (front discharge).
Front discharge is possible with an air discharge unit (option), which allows the installation in the drop-ceiling or sagging wall.
Single-flow type allows effective air discharge from corner or from drop-ceiling.
Providing 3 different settings of standard, draft prevention and ceiling soiling prevention, the auto swing mechanism realises even distribution of airflow and room temperature.
Main body
Downward discharge
Air discharge grille (Option)
3
32˚C 30˚C28˚C 26˚C 24˚C
22˚C
20˚C
2
1
0 1 2 3 4 5 6 (m)
(m)
500 mm
Drain pump is equipped as standard accessory with 500 mm lift.
Slim body needs only 220 mm space above the ceiling. If you use a panel spacer (option), the unit can be installed in the minimum space of 195 mm.
A long-life filter (maintenance free up to one year*) is equipped as standard accessory.
Panel spacer
20 mm
Min.195 mm
Ceiling Mounted Cassette Corner Type
FXKQ25MA/FXKQ32MA
FXKQ40MA/FXKQ63MA
* Remote controllers are an optional accessory. Refer to page 39 for remote controller details.
* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3
Indoor Unit Lineup
VRV Indoor Units
Slim Ceiling Mounted Duct Type
13
* Remote controllers are an optional accessory. Refer to page 39 for remote controller details.
Slim design, quietness and static pressure switching
FXDQ40NB/FXDQ50NB/FXDQ63NB
External static pressure selectable by remote controller switching make this indoor unit a very comfortable and flexible model.10 Pa-30 Pa/factory set: 10 Pa for FXDQ-PB models.15 Pa-44 Pa/factory set: 15 Pa for FXDQ-NB models.
Only 200 mm in height, this model can be installed in rooms with as little as 240 mm depth between the drop-ceiling and ceiling slab.
Only 700 mm in width and 23 kg in weight, this model is suitable to install in limited spaces like drop-ceilings in hotels.
Low operation sound level (dB(A))
The values of operation sound level represent those for rear-suction operation.Sound level values for bottom-suction operation can be obtained by adding 5 dB(A). Values are based on the following conditions:FXDQ-PB: external static pressure of 10 Pa; FXDQ-NB: external static pressure of 15 Pa.
1,100 mm in width for the FXDQ63NB model.
200 mm900 mm
Suction grille*AIR
AIR
Discharge grille*
Air filterSuspension bolt*
240 mm
* To be obtained locally
FXDQ-PB and FXDQ-NB models are available in two types to suit different installation conditions.FXDQ-PB/NBVE: with a drain pump (750 mm lift)
as a standard accessory
FXDQ-PB/NBVET: without a drain pump
Only 700 mm
200 mm
Great for hotel use!
Suited to use in drop-ceilings!
750 mm
Ceiling
Control of the airflow rate has been improved from 2-step to 3-step control.
36/34/32
63
35/33/31
50
34/32/30
40
33/31/29
20/25/32
Sound level(HH/H/L)
FXDQ-PB/NB
FXDQ20PB/FXDQ25PB/FXDQ32PB
Ceiling Mounted Duct Type
14
* Remote controllers are an optional accessory. Refer to page 39 for remote controller details.
Middle and high static pressureallows for flexible duct design
FXMQ20P/FXMQ25P/FXMQ32PFXMQ40P/FXMQ50P/FXMQ63PFXMQ80P/FXMQ100P/FXMQ125PFXMQ140P
Built-in Drain Pump (Option)Housing the drain pump inside the unit reduces the space required for installation.
All models are only 300 mm in height, an improvement over the 390 mm height of conventional models. The weight of the FXMQ40P has been reduced from 44 kg to 28 kg.
A DC fan motor increases the external static pressure capacity range to include middle to high static pressures, increasing design flexibility.
Indoor unit
470 mm
Indoor unit
470 mm
0–250mm
222 mm
Without drain pump With drain pump
Simplified Static Pressure ControlExternal static pressure can be easily adjusted using a change-over switch inside the electrical box to meet the resistance in the duct system.
Drain pump is equipped as standard accessory with 700 mm lift.
Control of the airflow rate has been improved from 2-step to 3-step control.
(dB(A))
46/45/43
140
42/40/38
63
43/41/39
80/100
41/39/37
50
39/37/35
40
34/32/30
32
33/31/29
20/25
Soundlevel
(HH/H/L)
FXMQ-P
700 mm
Ceiling
30 Pa–100 Pa for FXMQ20P-32P30 Pa–160 Pa for FXMQ40P50 Pa–200 Pa for FXMQ50P-125P50 Pa–140 Pa for FXMQ140P
Low operation sound level
Improved ease of installation
Improved ease of maintenance
The airflow rate can be controlled using a remote controller during test operation. With the conventional model, the airflow rate was controlled from the PC board. It is automatically adjusted to the range between approximately ±10% of the rated HH tap airflow for FXMQ20P–125P.
The drain pan can be detached for easy cleaning. An antibacterial treatment that uses silver ions has been applied to the drain pan, preventing the growth of slime, mould and bacteria that cause blockages and odours.
Energy-efficientThe adopted DC fan motor is much more efficient than the conventional AC motor, yielding an approximate 20% decrease in energy consumption (FXMQ125P).
25 mm
44/42/40
125
FXMQ200MA/FXMQ250MA
Indoor Unit Lineup
VRV Indoor Units
Ceiling Suspended Type
15
Slim body with quiet and wide airflow
Adoption of QUIET STREAM FAN
Drain pump kit (option) can be easily incorporated.
Easy-to-clean flat design
Maintenance is easier because everything can be performed from below the unit.
Non-dew Flap with no implanted bristles
FXHQ-MA
Sound level(H/L)
32
36/31
63
39/34
100
45/37
(dB(A))Low operation sound level
Uses the quiet stream fan and many more advanced technologies.
Sound absorptionmember
Turbulent flow is produced
Straightening vane
Quiet stream fan
Installation is easy
Maintenance is easy
Drain pump kit(built inside main unit)
600 mm
Bristle-free Flap minimises contamination and makes cleaning simpler.
Non-dew Flap
100°
Wide air discharge openings produce a spreading 100° airflow.
A long-life filter (maintenance free up to one year*) is equipped as standard accessory.
FXHQ32MA/FXHQ63MA
FXHQ100MA
* Remote controllers are an optional accessory. Refer to page 39 for remote controller details.
* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3
Wall Mounted Type
16
Sophisticated design and compact casing harmonised with your interior décor
Drain pan and air filter can be kept clean by mildew-proof polystyrene.
Compact and stylish design that does not detract from the décor of the room.
Drain pump kit is available as optional accessory, which lifts the drain 1,000 mm from the bottom of the unit.
Auto-swing realises efficiency of air distribution. The louvre closes automatically when the unit stops.
5 steps of discharge angle can be set by remote controller.
Washable grille, the front grille can be easily removed for washing.
Discharge angle is automatically set at the same angle as the previous operation when restarting. (Initial setting: 10˚ for cooling)
Flexible installationDrain pipe can be fitted to from either left or right sides.
Low operation sound level
46/39
63
42/36
50
39/34
40
37/29
32
36/29
25
35/29
20
Sound level(H/L)
FXAQ-MA
(dB(A))
FXAQ20MA/FXAQ25MA
FXAQ32MA/FXAQ40MA
FXAQ50MA/FXAQ63MA
Drain pump kit
1,000 mm
Height of drain-up
Indoor unit
* Remote controllers are an optional accessory. Refer to page 39 for remote controller details.
Indoor Unit Lineup
VRV Indoor Units
Floor Standing Type
17
Suitable for perimeter zone air conditioning
Wall hanging Floor installation
Floor Standing types can be hung on the wall for easier cleaning. Running the piping from the back allows the unit to be hung on walls. Cleaning under the unit, where dust tends to accumulate, is considerably easier.
A long-life filter (maintenance free up to one year*) is equipped as standard accessory.
The adoption of a fibre-less discharge grille featuring an original design to prevent condensation also helps prevent staining and makes cleaning easier.
Concealed Floor Standing Type
Designed to be concealed in the perimeter skirting-wall
Connecting port
Refrigerant piping
Applies also to Floor Standing type (FXLQ-MA).
The unit is concealed in skirting-wall of perimeter, that enables to create high class interior design.
The connecting port faces downward, greatly facilitating on-site piping work.
A long-life filter (maintenance free up to one year*) is equipped as standard accessory.
FXNQ20MA/FXNQ25MA
FXNQ32MA/FXNQ40MA
FXNQ50MA/FXNQ63MA
FXLQ20MA/FXLQ25MA
FXLQ32MA/FXLQ40MA
FXLQ50MA/FXLQ63MA
* Remote controllers are an optional accessory. Refer to page 39 for remote controller details.
* Remote controllers are an optional accessory. Refer to page 39 for remote controller details.
* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3
* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3
Ceiling Suspended Cassette Type
18
Connection unit series indoor units
FXUQ71MA/FXUQ100MA
FXUQ125MA
This thin indoor unit achievesoptimum air distribution, and can be installed
without the need for ceiling cavity.
Depending on installation site requirements or room conditions, 2-way, 3-way and 4-way discharge patterns are available.
4-way airflowfrom the centre of the store.
The 3-way airflow can distributecomfortable air throughout the room.
Only one unit is needed to distribute comfortable airthroughout an L-shaped store.
Connection unit Connection unit is the device for connecting above indoor unit to VRV III.
BEVQ-MA
Connection unit for indoor unit
Indoor unitPiping length*1
Indoor unit
Remote controller
Super wiring (DIII-NET)
Single-phase 220-240 Vpower supply
Refrigerant piping layout External wiring layout
Notes:
Gas pipeLiquid pipe
ModelMaximum piping lengthbetween the BEV unitand the indoor unit.
FXUQ-MA 5 m
*1
• When connecting centralised-control device, it is necessary to install an interface adaptor for an indoor unit (DTA102A52).
• Connection unit BEVQ-MA is necessary for each indoor unit.
• The refrigerant piping height difference between the indoor units and the BEV unit must be within 4 m.
• The BEV unit must be installed within a maximum height difference between indoor units of 15 m.
• Branching of the refrigerant piping is not possible downstream of the BEV unit.
VRV series outdoor unit
BEVQ71MA/BEVQ100MA/BEVQ125MA
* Remote controllers are an optional accessory. Refer to page 39 for remote controller details.
Indoor Unit Lineup
Residential Indoor Units
19
FCQ35B/FCQ50B/FCQ60B/FCQ71B
Option
Option
Signal receiver unitNote: Remote controller cables not included. Cables should beobtained locally.
Note: Wireless remote controllers and signal receiver units are sold as a set.
Specially designed for false ceilings—for a smooth, modern interior finish
All models feature a decoration panel with the same size and simple design in consideration of harmonised interior décor.
The indoor units weigh only 24 kg and require an installation space with a height of just 245 mm.
950 mm
950
mm
Same for all models
Decoration panel is optional
Min. 245 mm
Standard
Draft prevention
Soiling prevention
FCQ35B
33/29 dB (A)
FCQ50B
33/29 dB (A)
FCQ60B
35/30 dB (A)
FCQ71B
35/30 dB (A)
(H/L)
Drain pump is equipped as standard with 750 mm.
Three convenient patterns for auto-swing operation
These models have the power to provide a comfortable airflow even with a ceiling height of up to 3.8 m.
750 mm
Max. 3.8 m
Low operation sound level
Ceiling Mounted Cassette Type
with connectionto BP units
20
Quiet, compact, and designed for user comfort
T-bar grid does not need to be cut.
Designed to fit 600 mm wide ceiling grids Low draft performance is designed for your comfort.
Comfortable across all areas
Low operation sound level
Option
Signal receiver unitNote: Wireless remote controllers and signal receiver units are sold as a set.
OptionNote: Remote controller cables not included. Cables should beobtained locally.
FFQ25B/FFQ35B/FFQ50B/FFQ60B
575 mm
575 mm
700 mm
700 mm
286 mm
Compact
decorative panel
T-bar
600 mm600 mm
Ceiling panel
FFQ25B
29.5/24.5 dB (A)
FFQ35B
32/25 dB (A)
FFQ50B
36/27 dB (A)
FFQ60B
41/32 dB (A)
(H/L)
Horizontal Flow0° 0°
Less draught
Settable to 5 different levels between 0° and 35°
Settable to 5 different levels between 0° and 60°
Settable to 5 different levels between 25° and 60°
Auto-swing between 0° and 35°
Auto-swing between 0° and 60°
Auto-swing between 25° and 60°
Draft prevention setting(Set on site)
(Set on site)
Standard setting
Setting to prevent soiling of ceiling
Conditioned air is distributed evenly by Auto-swing operation.
Adjustable airflow angle to suit all room conditions.
AUTO-SWING
0° 0°
0°
25°
60° 60°
0°
35°
25°
60°
35°
60°
5 direction
Note: Angles shown above are provided as a guide. They may differ depending on the installation site.
Ceiling Mounted Cassette (Compact Multi Flow) Type
750 mm
Drain pump is equipped as standard accessory with 750 mm lift.
Indoor Unit Lineup
Ceiling Mounted Built-in Type
21
FBQ60B
41/35 dB (A)
FBQ71B
41/35 dB (A)
(H/L)
The indoor unit can be installed in rooms with as little as 350 mm between the drop ceiling and ceiling slab. It also works with both flexible and ordinary ducts.
To cope with the challenges of L-shaped or U-shaped spaces, it is possible to install the air discharge unit away from the main unit. This extends the possibilities for coping with human gathering patterns or sun lighting. At the same time, different types of architectural space can be kept comfortable.
1
3
7
1
11
2
3
3
4
8
9
7911
5
10
46
5
Air conditioner
Long-life filter
Air blow Air intake
425 mm or more46
5
2 2Air conditioner
Long-life filterAir blowAir intake
350 mm or more
Standard installation examples With high-efficiency filter
Ceiling return
In crawl space With canvas bellows and air intake panel (sold separately)
45 mm
46
5
Air conditioner
Long-life filter
Air blow
Air intake450 mm or more
8
Air conditioner Ordinary duct(procured locally)
Ordinary duct(procured locally)
Air blow Air intake
460 mm or more
8
Air intake
Ceiling return with high-efficiency filter With ordinary ducts
46
5
Air conditioner
Air blow Air intake
540 mm or more13
946
5
Air conditioner
Air blow
540 mm or more
Options
Air discharge opening adaptorDecorative panel
Canvas bellows and air intake panelFlexible ductAir discharge grille
Air discharge opening flangeRear intake blocking pad
6
7
8
Air discharge chamber
Inspection panelHigh-performance filter
11
12
13 Low-draft filter chamberBranch ductRear intake filter chamber
1011
2
2
2
Flexible air discharge unit to fit various forms of space
Note: Remote controller cables not included. Cables should beobtained locally.
Option
Drain pump is equipped as standard accessory with 250 mm lift.
250 mm
L-shaped room U-shaped room Long room
Low operation sound level
FBQ60B/FBQ71B
Residential Indoor Units with connectionto BP units
Slim Ceiling Mounted Duct Type
22
Slim and smooth design suits your shallow ceiling
700 mm width type
900/1,100 mm width type
Signals from the wireless remote controller aretransmitted to the signal receiver.
240 mm
200 mm
Only 700 mm
FDKS-EA
Dimensions (H x W x D)WeightAirflow rate (H)External static pressure
200 x 700 x 620 mm21 kg
8.7 m3/min30 Pa
200 x 900 x 620 mm25 kg
40 Pa
FDKS25EA FDKS35EA FDKS25CA FDKS35CA
9.5 m3/min 10 m3/min
FDKS25
35/31/29 dB (A)
FDKS35
35/31/29 dB (A)
FDKS50
37/33/31 dB (A)
FDKS60
38/34/32 dB (A)
(H/L/SL)Low operation sound level
Home Leave Operation prevents large rises or falls in the indoor temperature by continuing operation* while you are sleeping or out of your home. This means that an air-conditioned welcome awaits when you wake or return. It also means that the indoor temperature can quickly return to your favourite comfort setting.
Models in the FDKS-EA series are only 700 mm in width and 21 kg in weight, so are easily installed in limited spaces. Just 200 mm in height, all models can be installed in rooms with as little as 240 mm depth between the drop ceiling and ceiling slab, making them ideal for even shallow ceilings.
Notes: 1. To prevent an increase in operation noise, avoid
installing the air suction grille directly below the suction chamber.
2. Grilles, piping connections, ducts, and installation parts should be obtained locally. Slim Ceiling Mounted Duct type FDKS models do not have drain-up pumps.
3. The signal receiver unit must be located near the air suction inlet, because the unit includes a sensor that detects room temperature.
Suction grille (KDGF19A45)
Option
* Locally obtained partsAIRAir suction grille*
Suction duct*
Signal receiver
Air discharge duct* Suspension bolt*
Air discharge grille*
Signal receiver wireLength = 1,900 mm
Chamber
AIR
Air filter
* Home Leave Operation can be selected for any temperature from 18 to 32˚C for cooling operation and 10 to 30˚C for heating operation.
* Home Leave Operation function must be set using the remote controller when going to sleep or leaving the house, and after waking up or returning home.
Standard accessoryNote: Remote controllers other than the standard accessory wireless remote controller cannot be used.
FDKS25EA/FDKS35EA
FDKS25CA/FDKS35CA/FDKS50C/FDKS60C
Great for hotel use!
Indoor Unit Lineup
Wall Mounted Type
23
Wall Mounted indoor units achieve quiet sound levels of 22 dB (A).
Intelligent Eye with its infrared sensor automatically controls air conditioner operation according to human movement in a room. When there is no movement, it adjusts the temperature by 2˚C for energy savings.
Titanium apatite is a photocatalytic material with high adsorption power. Titanium apatite also effectively adsorbs and decomposes bacteria across its entire surface. The photocatalyst is activated simply by exposure to light.
These filters are not medical devices. Benefits such as the adsorption and decomposition of bacteria are only effective for substances that are collected on and in direct contact with the Titanium Apatite Photocatalytic Air-Purifying Filter.
Bacteria Removal TestTesting method: dropping methodResult certificate: No. 012553-1 and 012553-2Testing organisation: Japan Spinners Inspecting Foundation
3-D Airflow combines Vertical and Horizontal Auto-Swing to circulate air to every part of a room for uniform cooling of even large spaces.* This function is available for
FTKS50/60/71F.
FTKS25D/FTKS35D
FTKS50F/FTKS60F/FTKS71F
FTKS25D
37/25/22 dB (A)
FTKS35D
39/26/23 dB (A)
FTKS50F
43/34/31 dB (A)
FTKS60F
45/36/33 dB (A)
FTKS71F
46/37/34 dB (A)
(H/L/SL)
When you are in the room When you go out
A uniform temperatureis achieved throughout the entire room.
Titanium Apatite Photocatalytic Air-purifying Filter
catches dustAir filter
Stylish flat panel harmonises with your interior décor
* Remote controllers other than the standard accessory wireless remote controller cannot be used.
Residential Indoor Units with connectionto BP units
Standard accessory*
Standardaccessory*
24
Ceiling Mounted Cassette (Round Flow) Type
FXFQ25PVE
2.9
9,900
2,500
Galvanised steel plate
246X840X840
19.5
6.4
12.7
VP25 (External Dia, 32/Internal Dia, 25)
BYCP125K-W1
Fresh white
50X950X95050X950X95050X950X95050X950X95050X950X95050X950X95050X950X95050X950X950
5.55.55.55.55.55.55.55.5
246X840X840
19.5
6.4
12.7
FXFQ32PVE
3.7
12,600
3,200
15/13/1113/11.5/10 13/11.5/10
30/28.5/27 30/28.5/27
530/459/388
31/29/27
246X840X840
19.5
6.4
12.7
FXFQ40PVE
4.7
16,000
4,000
16/13.5/11
565/477/388459/406/353 459/406/353
32/29.5/27
246X840X840
19.5
6.4
12.7
FXFQ50PVE
5.8
19,800
5,000
19/16.5/13.5
671/583/477
34/31/28
246X840X840
22
9.5
15.9
FXFQ63PVE
7.3
24,900
6,300
21/18/15
742/636/530
36/33.5/31
246X840X840
22
9.5
15.9
FXFQ80PVE
9.3
2.8 3.6 4.5 5.6 7.1 9.0
31,700
8,000
FXFQ100PVE
11.6
39,600
10,000
FXFQ125PVE
14.5
11.2 14.0
49,500
12,500
32/26/20
1,130/918/706
43/37.5/32
288X840X840
25
9.5
15.9
33/28/22.5
1,165/989/794
44/39/34
288X840X840
25
9.5
15.9
1-phase, 220-240 V/220 V, 50/60 Hz
Casing
Airflow rate (HH/H/L)m3/min
cfm
MODEL
Cooling capacity
kW(*1)
(*2)
Btu/h(*1)
kcal/h(*1)
Power supply
Dimensions (HXWXD) mm
Machine weight kg
Pipingconnections
Drain
Panel(Option)
Model
Colour
mmDimensions (HXWXD)
Weight kg
Liquid (Flare)
Gas (Flare) mm
dB(A)Sound level (HH/H/L)
0.033 0.033 0.047 0.052 0.066 0.093 0.187 0.209kWPower consumption
kWPower consumption
Ceiling Mounted Cassette (Compact Multi Flow) Type
Galvanised steel plate
VP20 (External Dia, 26/Internal Dia, 20)
BYFQ60B8W1
White (6.5Y9.5/0.5)
55X700X700
2.7
9/7
318/247
30/25-32/26
286X575X575
18
6.4
12.7
FXZQ20MVE
2.3
7,800
2,000
2.2
1-phase, 220-240 V/220 V, 50/60 Hz
55X700X700
2.7
9/7
318/247
30/25-32/26
6.4
12.7
55X700X700
2.7
9.5/7.5
335/265
32/26-34/28
6.4
12.7
55X700X700
2.7
11/8
388/282
36/28-37/29
6.4
12.7
55X700X700
2.7
0.073 0.073 0.076 0.089 0.115
14/10
493/353
41/33-42/35
6.4
12.7
FXZQ25MVE
2.9
9,900
2,500
2.8
FXZQ32MVE
3.7
12,600
3,200
3.6
FXZQ40MVE
4.7
16,000
4,000
4.5
FXZQ50MVE
5.8
19,800
5,000
5.6
Casing
Airflow rate (H/L)m3/min
cfm
MODEL
Cooling capacity
kW(*1)
(*2)
Btu/h(*1)
kcal/h(*1)
Power supply
Dimensions (HXWXD) mm
Machine weight kg
Pipingconnections
Drain
Panel(Option)
Model
Colour
mmDimensions (HXWXD)
Weight kg
Liquid (Flare)
Gas (Flare) mm
dB(A)Sound level (H/L) 230 V-240 V
Note: Specifications are based on the following conditions;•Cooling: (*1) Indoor temp. of 27°CDB, 19.5°CWB, and outdoor temp. of 35°CDB. (*2) Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB.•Equivalent piping length: 7.5 m•Level difference: 0 m•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)•Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
Specifications
VRV Indoor Units
25
Ceiling Mounted Cassette Corner Type
Ceiling Mounted Cassette (Double Flow) Type
FXKQ25MAVE
2.9
9,900
2,500
Galvanised steel plate
11/9
FXKQ32MAVE
3.7
12,600
3,200
FXKQ40MAVE
4.7
16,000
4,000
FXKQ63MAVE
7.3
2.8 3.6 4.5 7.1
24,900
6,300
11/9 13/10 18/15
388/318 388/318 459/353 635/530
215X1,110X710
31.0
6.4
12.7
VP25 (External Dia, 32/Internal Dia, 25)
BYK45FJW1
White (10Y9/0.5)
70X1,240X800
8.5
215X1,110X710
31.0
6.4
12.7
70X1,240X800
8.5
215X1,110X710
31.0
6.4
12.7
70X1,240X800
8.5
215X1,310X710
34.0
9.5
15.9
BYK71FJW1
70X1,440X800
9.5
38/33 38/33 40/34 42/37
40/35 40/35 42/36 44/39
1-phase, 220-240 V/220 V, 50/60 Hz
Airflow rate (H/L)m3/min
cfm
Sound level (H/L) dB(A)220 V
240 V
0.066 0.066 0.076 0.105
kW(*1)
Btu/h(*1)
kcal/h(*1)
(*2)
Power supply
Cooling capacity
MODEL
Casing
Power consumption kW
Dimensions (HXWXD) mm
Machine weight kg
Pipingconnections
Drain
Panel(Option)
Model
Colour
mm
kg
Dimensions (HXWXD)
Liquid (Flare)
Gas (Flare) mm
Weight
Galvanised steel plate
7/5
247/177
32/27
305X775X600
26.0
6.4
12.7
VP25 (External Dia, 32/Internal Dia, 25)
BYBC32G-W1
White (10Y9/0.5)
53X1,030X680
8.0
9/6.5
318/230
34/28
305X775X600
26.0
6.4
12.7
53X1,030X680
8.0
9/6.5
318/230
34/28
305X775X600
26.0
6.4
12.7
53X1,030X680
8.0
12/9
424/318
34/29
305X990X600
31.0
6.4
12.7
BYBC50G-W1
53X1,245X680
8.5
12/9
424/318
34/29
305X990X600
32.0
6.4
12.7
53X1,245X680
8.5
16.5/13
582/459
37/32
305X1,175X600
35.0
9.5
15.9
BYBC63G-W1
53X1,430X680
9.5
26/21
918/741
39/34
305X1,665X600
47.0
9.5
15.9
BYBC125G-W1
53X1,920X680
12.0
33/25
1,165/883
44/38
34/29 36/30 36/30 37/32 37/32 39/34 41/36 46/40
305X1,665X600
48.0
9.5
15.9
53X1,920X680
12.0
FXCQ20MVE FXCQ25MVE FXCQ32MVE FXCQ40MVE FXCQ50MVE FXCQ63MVE FXCQ80MVE FXCQ125MVE
2.3
7,800
2,000
2.9
9,900
2,500
3.7
12,600
3,200
4.7
16,000
4,000
5.8
19,800
5,000
7.3
24,900
6,300
9.3
31,700
8,000
14.5
2.2 2.8 3.6 4.5 5.6 7.1 9.0 14.0
49,500
12,500
1-phase, 220-240 V/220 V, 50/60 Hz
0.077 0.092 0.092 0.130 0.130 0.161 0.209 0.256
Casing
Airflow rate (H/L)m3/min
Sound level (H/L)220 V
240 VdB(A)
cfm
Power consumption kW
MODEL
Cooling capacity
kW(*1)
(*2)
Btu/h(*1)
kcal/h(*1)
Power supply
Dimensions (HXWXD) mm
Machine weight kg
Pipingconnections
Drain
Panel(Option)
Model
Colour
mmDimensions (HXWXD)
Weight kg
Liquid (Flare)
Gas (Flare) mm
Note: Specifications are based on the following conditions;•Cooling: (*1) Indoor temp. of 27°CDB, 19.5°CWB, and outdoor temp. of 35°CDB. (*2) Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB.•Equivalent piping length: 7.5 m •Level difference: 0 m•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)•Sound level: (FXCQ-M) Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
(FXKQ-MA) Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
Specifications
VRV Indoor Units
26
Slim Ceiling Mounted Duct Type (700 mm width type)
Galvanised steel plate
7,800
2,000
9,900
2,500
12,600
3,200
2.2
0.086 0.086 0.089
8.0/7.2/6.4
282/254/226
8.0/7.2/6.4
282/254/226
8.0/7.2/6.4
282/254/226
33/31/29 33/31/29 33/31/29
Airflow rate (HH/H/L)m3/min
cfm
Casing
1-phase, 220-240 V/220 V, 50/60 Hz
200X700X620
23.0
6.4
12.7
200X700X620
23.0
6.4
12.7
200X700X620
23.0
6.4
12.7
2.8 3.6
2.3 2.9 3.7
VP20 (External Dia, 26/Internal Dia, 20)
30-10 1
FXDQ20PBVET FXDQ25PBVET FXDQ32PBVETMODEL without
drain pump
FXDQ20PBVE FXDQ25PBVE FXDQ32PBVEwith drain pump
Power consumption(FXDQ-PBVE) kW
0.067 0.067 0.070Power consumption(FXDQ-PBVET) kW
0.160 0.165 0.181Power consumption(FXDQ-NBVE) kW
0.147 0.152 0.168Power consumption(FXDQ-NBVET) kW
Power supply
Cooling capacity
kW(*1)
(*2)
Btu/h(*1)
kcal/h(*1)
Dimensions (HXWXD) mm
Machine weight kg
Pipingconnections
Drain
Liquid (Flare)
Gas (Flare) mm
dB(A)Sound level (HH/H/L)
PaExternal static pressure
32
Slim Ceiling Mounted Duct Type (900/1,100 mm width type)
Galvanised steel plate
1-phase, 220-240 V/220 V, 50/60 Hz
VP20 (External Dia, 26/Internal Dia, 20)
44-15 1
16,000
4,000
19,800
5,000
24,900
6,300
10.5/9.5/8.5
371/335/300
12.5/11.0/10.0
441/388/353
16.5/14.5/13.0
583/512/459
34/32/30 35/33/31 36/34/32
200X900X620
27.0
6.4
12.7
200X900X620
28.0
6.4
12.7
200X1,100X620
31.0
9.5
15.9
4.5 5.6 7.1
4.7 5.8 7.3
FXDQ40NBVET FXDQ50NBVET FXDQ63NBVET
FXDQ40NBVE FXDQ50NBVE FXDQ63NBVE
Airflow rate (HH/H/L)m3/min
cfm
Casing
MODEL without drain pump
with drain pump
Power supply
Cooling capacity
kW(*1)
(*2)
Btu/h(*1)
kcal/h(*1)
Dimensions (HXWXD) mm
Machine weight kg
Pipingconnections
Drain
Liquid (Flare)
Gas (Flare) mm
dB(A)Sound level (HH/H/L)
PaExternal static pressure
32
Note: Specifications are based on the following conditions;•Cooling: (*1) Indoor temp. of 27°CDB, 19.5°CWB, and outdoor temp. of 35°CDB. (*2) Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. 1 : External static pressure is changeable to set by the remote controller. This pressure means "High static pressure - Standard". (Factory setting
is 10 Pa for FXDQ-PB models and 15 Pa for FXDQ-NB models.) 2: The values of operation sound level represent those for rear-suction operation. Sound level values for bottom-suction operation can be obtained by adding 5 dB(A). 3: Values are based on the following conditions: external static pressure of 10 Pa.•Equivalent piping length: 7.5 m •Level difference: 0 m•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)•Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
27
Ceiling Mounted Duct Type
Note: Specifications are based on the following conditions;•Cooling: (*1) Indoor temp. of 27°CDB, 19.5°CWB, and outdoor temp. of 35°CDB. (*2) Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. 1: External static pressure can be modified using a remote controller that offers seven (FXMQ20-32P), thirteen (FXMQ40P), fourteen (FXMQ50-
125P) or ten (FXMQ140P) levels of control. These values indicate the lowest and highest possible static pressures. The standard static pressure is 50 Pa for FXMQ20-32P and 100 Pa for FXMQ40-140P.
•Equivalent piping length: 7.5 m •Level difference: 0 m•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)•Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
FXMQ40PVE FXMQ50PVE
4.7
16,000
4,000
Galvanised steel plate
565/459/388
300X700X700
28.0
VP25 (External Dia, 32/Internal Dia, 25)
5.8
19,800
5,000
635/582/530
300X1,000X700
36.0
4.5 5.6
cfm
External static pressure
Casing
1-phase, 220-240 V/220 V, 50/60 Hz
6.4
12.7
6.4
12.7
Power consumption kW 0.194 0.215
Airflow rate (HH/H/L)16/13/11 18/16.5/15m3/min
Pa 30-160 50-2001 1
39/37/35
FXMQ20PVE
2.3
7,800
2,000
318/265/230
300X550X700
25.0
2.2
6.4
12.7
0.081
9/7.5/6.5
30-100
33/31/29
FXMQ25PVE
2.9
9,900
2,500
318/265/230
300X550X700
25.0
2.8
6.4
12.7
0.081
9/7.5/6.5
30-100
33/31/29
FXMQ32PVE
3.7
12,600
3,200
335/282/247
300X550X700
25.0
3.6
6.4
12.7
0.085
9.5/8/7
30-100
34/32/30 41/39/37Sound level (HH/H/L) dB(A)
(*1)
(*2)
MODELPower supply
Cooling capacity
kW
Btu/h(*1)
kcal/h(*1)
Drain
Dimensions (HXWXD) mm
Machine weight kg
Pipingconnections
Liquid (Flare)
Gas (Flare) mm
1 1 1
FXMQ63PVE FXMQ80PVE FXMQ100PVE FXMQ125PVE
Galvanised steel plate
VP25 (External Dia, 32/Internal Dia, 25)
7.3
24,900
6,300
688/618/565
300X1,000X700
36.0
9.5
15.9
9.3
31,700
8,000
883/794/706
300X1,000X700
36.0
9.5
15.9
11.6
39,600
10,000
1,130/953/812
300X1,400X700
46.0
9.5
15.9
14.5
49,500
12,500
1,377/1,165/988
300X1,400X700
46.0
9.5
15.9
7.1 9.0 11.2 14.0
cfm
External static pressure
Casing
1-phase, 220-240 V/220 V, 50/60 Hz
Power consumption kW 0.230 0.298/ 0.376 0.461
Airflow rate (HH/H/L)19.5/17.5/16 25/22.5/20 32/27/23 39/33/28m3/min
Pa 50-200 50-200 50-200 50-200 1 1 1 1
42/40/38 43/41/39 43/41/39 44/42/40
FXMQ140PVE
16.7
57,000
14,300
1,624/1,377/1,130
300X1,400X700
47.0
9.5
15.9
16.0
0.461
46/39/32
50-140 1
46/45/43Sound level (HH/H/L) dB(A)
(*1)
(*2)
MODELPower supply
Cooling capacity
kW
Btu/h(*1)
kcal/h(*1)
Drain
Dimensions (HXWXD) mm
Machine weight kg
Liquid (Flare)
Gas (Flare) mmPipingconnections
Specifications
VRV Indoor Units
28
Ceiling Mounted Duct Type
Ceiling Suspended Type
FXMQ200MAVE FXMQ250MAVE
23.0
78,500
19,800
28.8
22.4 28.0
98,300
24,800
1-phase, 220-240 V/220 V, 50/60 Hz
MODELPower supply
Cooling capacity
kW(*1)
(*2)
Btu/h(*1)
kcal/h(*1)
Power consumption kW
External static pressure Pa
Galvanised steel plate
58/50
2,047/1,765
470X1,380X1,100
137.0
9.5
19.1
PS1B
72/62
2,542/2,189
470X1,380X1,100
137.0
9.5
22.2
132-221 191-270 1 1
1.294 1.465
48/45 48/45
49/46 49/46
Casing
m3/min
cfm
Dimensions (HXWXD) mm
Machine weight kg
Airflow rate (H/L)
Sound level(H/L)
dB(A)220 V
240 V
Pipingconnections
Drain
Liquid (Flare)
Gas (Brazing) mm
Note: Specifications are based on the following conditions;•Cooling: (*1) Indoor temp. of 27°CDB, 19.5°CWB, and outdoor temp. of 35°CDB.
(*2) Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. 1 : External static pressure is changeable to change over the connectors inside electrical box, this pressure means "Standard-High static pressure".•Equivalent piping length: 7.5 m•Level difference: 0 m•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)•Sound level: (FXMQ-MA) Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
(FXHQ-MA) Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward.During actual operation, these values are normally somewhat higher as a result of ambient conditions.
MODELPower supply
Cooling capacity
kW(*1)
(*2)
Btu/h(*1)
kcal/h(*1)
cfm
Dimensions (HXWXD) mm
Machine weight kg
m3/minAirflow rate (H/L)
dB(A)Sound level (H/L)
Pipingconnections
Drain
Liquid (Flare)
Gas (Flare) mm
FXHQ32MAVE
3.7
12,600
3,200
White (10Y9/0.5)
FXHQ63MAVE
7.3
24,900
6,300
FXHQ100MAVE
11.6
3.6 7.1 11.2
39,600
10,000
424/353 618/494 883/688
195X960X680
24.0
6.4
12.7
VP20 (External Dia, 26/Internal Dia, 20)
195X1,160X680
28.0
9.5
15.9
195X1,400X680
33.0
9.5
15.9
Casing
1-phase, 220-240 V/220 V, 50/60 Hz
36/31 39/34 45/37
kW 0.111 0.115 0.135
12/10 17.5/14 25/19.5
Power consumption
29
Wall Mounted Type
FXAQ25MAVE
2.9
White (3.0Y8.5/0.5)
36/29
290X795X230
11.0
Casing
1-phase, 220-240 V/220 V, 50/60 Hz
37/29
290X795X230
11.0
FXAQ40MAVE
4.7
39/34
290X1,050X230
14.0
9,900 16,000
2,500 4,000
282/177 318/194 424/318
m3/minAirflow rate (H/L)
cfm
8/5 9/5.5
FXAQ32MAVE
3.7
12,600
3,200
2.8
FXAQ20MAVE
2.3
35/29
290X795X230
11.0
7,800
2,000
265/159
7.5/4.5
2.2 4.53.6
12/9
VP13 (External Dia, 18/Internal Dia, 13)
6.4 6.4 6.4 6.4
12.7 12.7 12.7 12.7
42/36
290X1,050X230
14.0
FXAQ63MAVE
7.3
24,900
6,300
15/12 19/14
530/424
46/39
290X1,050X230
14.0
671/494
5,000
FXAQ50MAVE
5.8
19,800
7.15.6
6.4 9.5
12.7 15.9
0.022 0.027 0.020 0.027 0.0500.016
MODELPower supply
Cooling capacity
kW(*1)
(*2)
Btu/h(*1)
kcal/h(*1)
Dimensions (HXWXD) mm
Machine weight kg
dB(A)Sound level (H/L)
Pipingconnections
Drain
Liquid (Flare)
Gas (Flare) mm
Power consumption kW
Floor Standing Type/Concealed Floor Standing Type
FXLQ
FXNQ
Note: Specifications are based on the following conditions;•Cooling: (*1) Indoor temp. of 27°CDB, 19.5°CWB, and outdoor temp. of 35°CDB. (*2) Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB.•Equivalent piping length: 7.5 m•Level difference: 0 m•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)•Sound level: (FXAQ-MA) Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward.
(FXLQ-MA, FXNQ-MA) Anechoic chamber conversion value, measured at a point 1.5 m in front of the unit at a height of 1.5 m.During actual operation, these values are normally somewhat higher as a result of ambient conditions.
FXLQ20MAVE
2.3
7,800
2,000
FXLQ: Ivory white (5Y7.5/1)/FXNQ: Galvanised steel plate
Airflow rate (H/L)m3/min
cfm
7/6
247/212
600X1,000X222
25.0
6.4
12.7
21O.D.
2.2
FXLQ25MAVE
2.9
9,900
2,500
7/6
247/212
600X1,000X222
25.0
6.4
12.7
282/212 388/300 494/388 565/424
2.8
FXLQ32MAVE
3.7
12,600
3,200
8/6
600X1,140X222
30.0
6.4
12.7
3.6
FXLQ40MAVE
4.7
16,000
4,000
11/8.5
600X1,140X222
30.0
6.4
12.7
4.5
FXLQ50MAVE
5.8
19,800
5,000
14/11
600X1,420X222
36.0
6.4
12.7
5.6
FXLQ63MAVE
FXNQ20MAVE FXNQ25MAVE FXNQ32MAVE FXNQ40MAVE FXNQ50MAVE FXNQ63MAVE
7.3
24,900
6,300
16/12
600X1,420X222
610X930X220 610X930X220 610X1,070X220 610X1,070X220 610X1,350X220 610X1,350X220
36.0
19.0 19.0 23.0 23.0 27.0 27.0
9.5
15.9
7.1
35/32 35/32 35/32 38/33 39/34 40/35
37/34 37/34 37/34 40/35 41/36 42/37
1-phase, 220-240 V/220 V, 50/60 Hz
Sound level (H/L) dB(A)220 V
240 V
0.049 0.049 0.090 0.090 0.110 0.110
Casing
kWPower consumption
MODEL
Power supply
Cooling capacity
kW(*1)
(*2)
Btu/h(*1)
kcal/h(*1)
Dimensions (HXWXD)
Machine weight
mmFXLQ
FXNQ
kgFXLQ
FXNQ
Pipingconnections
Drain
Liquid (Flare)
Gas (Flare) mm
Specifications
VRV Indoor Units
30
Ceiling Suspended Cassette Type
Connection unit series indoor units
* A type of BEV unit is necessary for each Connection unit series indoor unit. Refer to the Engineering Data for details.* Group control between Connection Unit series equipment within one system is possible. However, group control with the other
VRV indoor units is not possible.
cfm
kW(*1)
(*2)
Kcal/h(*1)
Power supply
8.3
7,100
1-phase, 220-240 V, 50 Hz
Btu/h(*1) 28,300
Ind
oo
r u
nit Airflow rate (H/L)
Casing
mmDimensions (HXWXD)
kgMachine weight
Piping connections
Liquid
Gas
Drain VP 20 (External Dia. 26/Internal Dia. 20)
25
White (10Y9/0.5)
671/494
165X895X895
9.5 (Flare)
15.9 (Flare)
11.6
10,000
39,600
31
1,024/741
230X895X895
14.5
8.0 11.2 14.0
12,500
49,500
Sound level (H/L) dB(A) 40/35 43/38 44/39
31
1,130/812
230X895X895
mm
Cooling capacity
MODELIndoor unit
Connection unit BEVQ71MAVE
FXUQ71MAV1
BEVQ100MAVE
FXUQ100MAV1
BEVQ125MAVE
FXUQ125MAV1
Note: Specifications are based on the following conditions;•Cooling: (*1) Indoor temp. of 27°CDB, 19.5°CWB, and outdoor temp. of 35°CDB. (*2) Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB.•Equivalent piping length: 7.5 m •Level difference: 0 m•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)•Sound level: Anechoic chamber conversion value, measured at a point 1.5 m below the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
kWPower consumption 0.189 0.298 0.298
m3/min 19/14 29/21 32/23
230 V
31
Ceiling Mounted Cassette (Compact Multi Flow) Type
1-phase, 220-240 V/220 V, 50/60 Hz
2 steps
FCQ71BVE
35/30
19.0 (671)
ø9.5
ø15.9
FCQ60BVEFCQ50BVE
15.0 (530)
ø12.7
FCQ35BVE
33/29
14.0 (494)
ø6.4
ø9.5
MODELPower supply
Both liquid and gas pipesHeat insulation
Fan speed
Microcomputer control
I.D ø25XO.D ø32
230X840X840
Temperature control
Airflow rates (H)
Sound levels (H/L)* dB (A)
m3/min (cfm)
Dimensions (HXWXD) mm
24Machine weight kg
40X950X950
BYC125K-W1
White
mm
5kg
Pipingconnections
Panel(Option)
Drain
Liquid (Flare)
Model
Colour
Dimensions (HXWXD)
Weight
Gas (Flare) mm
Note: * For 220 V operation.
600 x 600
Ceiling Mounted Cassette Type
1-phase, 220-240 V, 50 Hz
2 steps
FFQ60BV1B
41/32
15.0 (530)
ø12.7
FFQ50BV1BFFQ35BV1B
10.0 (353)
FFQ25BV1B
9.0 (318)
ø6.4
ø9.5
MODELPower supply
Both liquid and gas pipesHeat insulation
Fan speed
Microcomputer control
VP20 (External Dia. 26/Internal Dia. 20)
286X575X575
Temperature control
Airflow rates (H)
Sound levels (H/L)* dB (A)
m3/min (cfm)
Dimensions (HXWXD) mm
17.5Machine weight kg
55X700X700
BYFQ60B8W1
White
mm
2.7kg
Pipingconnections
Panel(Option)
Drain
Liquid (Flare)
Model
Colour
Dimensions (HXWXD)
Weight
Gas (Flare) mm
36/2732/2529.5/24.5
12.0 (424)
Note: * Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
Specifications
Residential Indoor Units with connectionto BP units
Residential indoor units with connection to BP unitsResidential indoor units can be connected to the VRVIII single outdoor unit series by BP units.
32
1-phase, 220-240 V, 50 Hz
2 steps
41/35
FBQ71BV1
19.0 (670)
FBQ60BV1
17.0 (600)
ø9.5ø6.4
ø15.9ø12.7
MODELPower supply
Both liquid and gas pipesHeat insulation
Fan speed
Microcomputer control
I.D ø25XO.D ø32
300X1,000X800
Temperature control
Airflow rates (H)
Sound levels (H/L)* dB (A)
m3/min (cfm)
Dimensions (HXWXD) mm
41Machine weight kg
55X1,100X500
BYBS71DJW1
White
mm
4.5kg
Pipingconnections
Panel(Option)
Drain
Liquid (Flare)
Model
Colour
Dimensions (HXWXD)
Weight
Gas (Flare) mm
Note: * For 220 V operation.
Ceiling Mounted Built-in Type
Slim Ceiling Mounted Duct Type
1-phase, 220-240 V/220 V, 50/60 Hz
5 steps, quiet and automatic
FDKS25EAVMB
8.7 (307)
ø6.4
MODELPower supply
Both liquid and gas pipesHeat insulation
Fan speed
Microcomputer control
VP20 (External Dia. 26/Internal Dia. 20)
Temperature control
Airflow rates (H)
Sound levels (H/L/SL)* dB (A)
m3/min (cfm)
Dimensions (HXWXD) mm
Machine weight kg
Pipingconnections
Drain
Liquid (Flare)
Gas (Flare) mm
Note: * The operation sound level values represent those for rear-suction operation and an external static pressure of 30 Pa for FDKS-EA and 40 Pa for FDKS-C. Sound level values for bottom-suction operation can be obtained by adding 6 dB (A) for FDKS-EA and 5 dB (A) for FDKS-C.
35/31/29
FDKS35EAVMB FDKS25CAVMB
9.5 (335)
FDKS35CAVMB
10.0 (353)
FDKS50CVMB
12.0 (424)
37/33/31
FDKS60CVMB
16.0 (565)
21 25 27 30
200X700X620 200X900X620 200X1,100X620
External static pressure Pa 30 40
38/34/32
ø9.5 ø12.7 ø15.9
1-phase, 220-240 V/220 V, 50/60 Hz
FTKS71FVMFTKS60FVMFTKS35DVMFTKS25DVMMODELPower supply
WhiteFront panel colour
5 steps, quiet and automatic
46/37/34
17.4 (614)
ø15.9
8.9 (314)
ø12.7
37/25/22 39/26/23
8.7 (307)
ø6.4
ø9.5
Both liquid and gas pipesHeat insulation
Fan speed
Microcomputer control
ø18.0
283X800X195
Temperature control
Airflow rates (H)
Sound levels (H/L/SL) dB (A)
m3/min (cfm)
Dimensions (HXWXD) mm
Machine weight kg
Pipingconnections
Drain
Liquid (Flare)
Gas (Flare) mm
Wall Mounted Type
45/36/33
16.2 (572)
FTKS50FVM
43/34/31
14.7 (519)
290X1,050X238
9 12
33
1-phase, 220-240 V/220 V, 50/60 Hz
BPMKS967B2BBPMKS967B3BMODELPower supply
3 (connectable to 1-3 indoor units) 2 (connectable to 1-2 indoor units)Number of ports
0.05
3 for power supply (including earth wiring), 2 for interunit wiring (outdoor unit-BP, BP-BP), 4 for interunit wiring (BP-indoor unit)Number of wiring connections
ø9.5X1
ø19.1X1
Liquid
Gas
mm
mm
mm
mm
Pipingconnections(Brazing)
Both liquid and gas pipesHeat insulation
2.5 kW class to 7.1 kW class residential indoor unitsConnectable indoor units
Running current A
2.5Min. rated capacity of connectable indoor units kW
180X294 (+356*)X350Dimensions (HXWXD) mm
8Machine weight kg
10Power consumption W
Note: * Total auxiliary piping length.
7.5
Max. rated capacity of connectable indoor units kW 20.8 14.2
ø6.4X3 ø6.4X2
ø15.9X3 ø15.9X2
Main
Branch
Main
Branch
Specifications
BP units for connection to residential indoor units• A BP unit is an innovative development which allows VRVIII single outdoor unit series to be connected to residential indoor units.
• A BP unit has the ability to precisely vary refrigerant volume to meet the cooling requirements of individual room spaces.
• A BP unit is easy to disassemble, making repairing and recycling simple.
for connection toresidential indoor unitsBP Units
34
Specifications—Indoor Units
•Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
Note: Specifications are based on the following conditions;•Cooling: (*1) Indoor temp. of 27°CDB, 19.5°CWB, and outdoor temp. of 35°CDB. (*2) Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB.•Equivalent piping length: 7.5 m•Level difference: 0 m
RSXQ8PY1 RSXQ18PY1
MODEL
22.5
76,800
19,400
22.4
3-phase 4-wire system, 380–415 V, 50 Hz
49.3
168,000
42,400
49.0
R-410A
3.6X1
188
57
1,680X930X765
180
20-100
Hermetically sealed scroll type
Ivory white (5Y7.5/1)
4.7
9.5 (Brazing)
19.1 (Brazing)
324
63
239
9-100
6.7
15.9 (Brazing)
28.6 (Brazing)
(2.8+4.5+4.5)X1
5.24
RSXQ10PY1
28.2
96,200
24,300
28.0
(1.4+4.5)X1
4.9
232
58
185
14-100
9.5 (Brazing)
22.2 (Brazing)
7.90
RSXQ12PY1
33.7
115,000
29,000
33.5
268
60
233
14-100
6.0
12.7 (Brazing)
28.6 (Brazing)
(1.8+4.5)X1
1,680X1,240X765
8.93
RSXQ14PY1
40.2
137,000
34,600
40.0
(1.4+4.5+4.5)X1
312
60
233
10-100
6.3
12.7 (Brazing)
28.6 (Brazing)
12.4
RSXQ16PY1
45.3
155,000
39,000
45.0
312
60
233
10-100
6.5
12.7 (Brazing)
28.6 (Brazing)
(2.7+4.5+4.5)X1
14.2 16.4
Cooling capacity (*1)(*2) Btu/h(*1)
(*1)kW
(*2)
Power supply
kcal/h(*1)
Refrigerant
Machine weight kg
dB(A)
Dimensions (HXWXD) mm
m3/min
Capacity control
Compressor
Sound level
–5 to 43°CDBOperation range
%
Airflow rate
Casing colour
Pipingconnections
Motor output kW
Type
Charge kg
Type
Liquid
Gasmm
Power consumption (*2) kW
single outdoor unit series
SpecificationsOutdoor Units
Outdoor unit combinations
Maximum number ofconnectable indoor units
Total capacity index of connectable indoor units*
Combination (%)*
50% 100% 130%
kW
260
325
390
455
520
200
250
300
350
400
100
125
150
175
200
22.4
28.0
33.5
40.0
45.0
13
16
19
22
26
Capacityindex
200
250
300
350
400
58545022549.0
HP
8 HP
10 HP
12 HP
14 HP
16 HP
18 HP 29450
* Total capacity index of connectable indoor units must be 50%–130% of the capacity index of the outdoor unit.
Model name
RSXQ8PY1
RSXQ10PY1
RSXQ12PY1
RSXQ14PY1
RSXQ16PY1
RSXQ18PY1
Combination ratio =Total capacity index of the indoor units
Capacity index of the outdoor unit
35
Ceiling Mounted Cassette (Round Flow) Type
Ceiling Mounted Cassette (Double Flow) Type
No.
1
2
Decoration panelHigh efficiency filter 65% 1
High efficiency filter 90% 1
Long life replacement filter
Filter related bottom suction
FXCQ20MFXCQ25MFXCQ32M
FXCQ40M FXCQ50M FXCQ63M FXCQ80M FXCQ125M
KAFJ532G36 KAFJ532G56 KAFJ532G160KAFJ532G80KAFJ533G36 KAFJ533G56 KAFJ533G160KAFJ533G80KDDFJ53G36Filter chamber KDDFJ53G56 KDDFJ53G160KDDFJ53G80KAFJ531G36 KAFJ531G56 KAFJ531G160KAFJ531G80
Type
ItemBYBC32G-W1 BYBC50G-W1 BYBC125G-W1BYBC63G-W1
Note: 1 Filter chamber is required if installing high efficiency filter.
No. FXDQ25PB FXDQ32PBFXDQ20PB
1 KDT25N32Insulation kit for high humidity
Slim Ceiling Mounted Duct Type (700 mm width type)Type
Item
Slim Ceiling Mounted Duct Type (900/1,100 mm width type)No.
1 KDT25N50 KDT25N63Insulation kit for high humidity
TypeItem FXDQ63NBFXDQ50NBFXDQ40NB
Ceiling Mounted Cassette Corner TypeNo.
TypeItem FXKQ25MA FXKQ32MA FXKQ40MA FXKQ63MA
1
2
BYK45FJW1 BYK71FJW1KPBJ52F56W KPBJ52F80WKAFJ521F56 KAFJ521F80
K-HV7AW K-HV9AWKDBJ52F56W KDBJ52F80WKFDJ52FA56 KFDJ52FA80
Panel related
Air inlet and air discharge outlet related
Decoration panelPanel spacerLong life replacement filterAir discharge grilleAir discharge blind panelFlexible duct (with shutter)
Ceiling Mounted Cassette (Compact Multi Flow) Type
FXFQ25P FXFQ32P FXFQ40P FXFQ50P FXFQ63P FXFQ80P FXFQ100P FXFQ125P1
4
BYCP125K-W1
KAFP556B80 KAFP556B160KAFP557B80 KAFP557B160KAFP552B80 KAFP552B160KAFP553B80 KAFP553B160
KDTP55K160
KDJP55B160
Filter related
5 Fresh air intake kit
Decoration panel2 KDBH55K160FSealing member of air discharge outlet3 KDBP55H160FAPanel spacer
High efficiency filter unit 65%High efficiency filter unit 90%Replacement high efficiency filter 65%Replacement high efficiency filter 90%Filter chamberLong life replacement filter Non-woven type
Chamber typeWithout T shape and fanWith T shape without fan
KDDFP55B160
Ultra long-life filterReplacement ultra long-life filter
Direct installation type
KAFP551K160KAFP55B160
KAFP55H160HKDDP55B160
KDDP55B160KKDDP55X160
No. Type
Item
6 KDJP55B80Branch duct chamber7 KKSJ55KA160Chamber connection kit8 KDTP55K80Insulation kit for high humidity
No.
FXZQ20M FXZQ25M FXZQ32M FXZQ40M FXZQ50M1 Decoration panel2 Sealing member of air discharge outlet3 Panel spacer4 Replacement long-life filter
BYFQ60B8W1KDBH44BA60
KDBQ44BA60AKAFQ441BA60
5 Fresh air intake kit Direct installation type KDDQ44XA60
TypeItem
Option List
VRV Indoor Units
36
Ceiling Suspended Type
Wall Mounted TypeFXAQ25MAFXAQ20MA
1 Drain pump kit K-KDU572EVE
FXAQ32MA FXAQ40MA FXAQ50MA FXAQ63MANo. Type
Item
Floor Standing TypeFXLQ20MA
1 Long life replacement filter
FXLQ25MA FXLQ32MA FXLQ40MA FXLQ50MA FXLQ63MA
KAFJ361K28 KAFJ361K45 KAFJ361K71
No. TypeItem
Concealed Floor Standing TypeFXNQ20MA
1 Long life replacement filter
FXNQ25MA FXNQ32MA FXNQ40MA FXNQ50MA FXNQ63MA
KAFJ361K28 KAFJ361K45 KAFJ361K71
No. TypeItem
Ceiling Suspended Cassette Type
Ceiling Mounted Duct TypeNo. FXMQ40P
FXMQ50PFXMQ63PFXMQ80P
FXMQ20PFXMQ25PFXMQ32P
FXMQ100PFXMQ125PFXMQ140P
FXMQ200MAFXMQ250MA
KDU30L250VE—
KAFJ372L280KAF372AA80 KAF372AA160
KAFJ373L280KAF373AA80 KAF373AA160
KDJ3705L280KDDF37AA80 KDDF37AA160
KAFJ371L280KAF371AA80 KAF371AA160
KAF375AA80
KAF372AA56
KAF373AA56
KDDF37AA56
KAF371AA56
KAF375AA56
KAF372AA36
KAF373AA36
KDDF37AA36
KAF371AA36
KAF375AA36 KAF375AA160
KTB25KA80W KTB25KA160W
KTBJ25K80F KTBJ25K160F
KTBJ25K80T
KTB25KA56W
KTBJ25K56F
KTBJ25K56T
KTBJ25K36W
KTBJ25K36F
KTBJ25K36T KTBJ25K160T
—
KDAJ25K71AKDAJ25K56AKDAJ25K36A KDAJ25K140A
Item1 Drain pump kit
3 Filter chamber
2 High efficiency filter65%
90%
4 Long life replacement filter
5 Long life filter chamber kit
6 Service panel
White
Fresh white
Brown
7 Air discharge adaptor
Type
FXHQ32MA
1 Drain pump kit
2 Replacement long-life filter (Resin net)
KDU50N60VE
KAF501DA56
3 L-type piping kit (for upward direction) KHFP5MA63
FXHQ63MA
KDU50N125VE
KAF501DA80
KHFP5MA160
FXHQ100MA
KAF501DA112
No. Type
Item
No.
Replacement long-life filter12345
Sealing member of air discharge outlet (*1)
Decoration panel for air dischargeVertical flap kitL-shape piping kit
FXUQ71MA
KDBH49FA80KDBT49FA80KDGJ49FA80
KHFP49MA140
KDBH49FA140KDBT49FA140KDGJ49FA140
FXUQ100MA FXUQ125MA
KAF495FA140
(*1): This option is necessary for setting up 2-way (opposing directional) airflow when the air conditioner is installed.Note:
TypeItem
37
Ceiling Mounted Cassette TypeFCQ35BVE FCQ50BVE FCQ60BVE FCQ71BVE
1
4
BYC125K-W1
High-efficiency filter
Decoration panel2 KDBP55H160WAPanel spacer
3KDDP55D160
KDDP55D160KKDDJ55X160KAFP556D80KAFP557D80
Fresh air intake kitDirect installation type*3
(Colourimetric method 65%) (Colourimetric method 90%)
5Replacement high-efficiency filter
(Colourimetric method 65%) (Colourimetric method 90%)
Chambertype
Without T-shaped pipe and fan*1
With T-shaped pipe, without fan*2
KAFP552H80 KAFP553H80
KDDF55DA160KAF551KA160
KDJ55K80
No. Type
Item
6 High-efficiency filter chamber7 Replacement long-life filter 8 Branch duct chamber
Notes: *1. With a suction chamber. Fresh air intake is from 2 holes on the sides of the connection chamber. (This method should be selected if a wireless remote controller is used.)*2. Without a suction chamber. Fresh air intake is from 2 holes on the connection chamber via a T-shaped pipe connection. (A wireless remote controller cannot be used in this case.)*3. Without a suction chamber. Fresh air intake is directly from a hole on the main unit.
Ceiling Mounted Cassette (Compact Multi Flow) TypeFFQ25BV1B FFQ35BV1B FFQ50BV1B FFQ60BV1B
1 BYFQ60B8W1Decoration panel
No. Type
Item
KAFQ441BA602 Replacement long-life filterKDDQ44XA603 Fresh air intake kitKDBH44BA604 Sealing member for air discharge outlet
KDBQ44BA60A5 Panel spacer
FDKS35EAVMBFDKS25EAVMB
1 Suction grille KDGF19A45
2 Insulation kit for high humidity KDT25N32
FDKS25CAVMB FDKS35CAVMB FDKS50CVMB FDKS60CVMBNo. Type
Item
Slim Ceiling Mounted Duct Type
Direct installation type
Ceiling Mounted Built-in TypeFBQ60BV1 FBQ71BV1
1 BYBS71DJW1Decoration panel2 KTBJ25L80WService access panel
4 KAFJ251K80Replacement long-life filter Resin netKAF253LA80KAF252LA80
KAJ25LA80DKAJ25LA80B
No. Type
Item
5 Filter chamber for bottom suction 6 Filter chamber for rear suction
KSAJ25K807 Canvas duct
KDJ2507K8014 Flange for suction
KBBJ25KA8012 Blind boardKDAJ25K7113 Adaptor for discharge
3 High-efficiency filter(Colourimetric method 65%)(Colourimetric method 90%)
K-DG9DWK-DG5DW
8 Discharge grilleø150ø200
K-DDV20A10 Branch duct ø150 ø200
K-FDS201C(1m)/K-FDS202C(2m)/K-FDS203C(3m)/K-FDS204C(4m)/K-FDS205C(5m)/K-FDS206C(6m)K-FDS151C(1m)/K-FDS152C(2m)/K-FDS153C(3m)/K-FDS154C(4m)/K-FDS155C(5m)/K-FDS156C(6m)
11 Flexible ductø150ø200
K-DGC9DK-DGC5D
9 Discharge chamberø150ø200
KDT25N50 KDT25N63
Option ListResidential Indoor Units with connection
to BP units
38
BPMKS967B2B
1 REFNET joint KHRP26A22T
BPMKS967B3BNo. Type
Item
FTKS35DVMFTKS25DVM
1 Titanium apatite photocatalytic air-purifying filter KAF970A46
FTKS50FVM FTKS60FVM FTKS71FVMNo. Type
Item
Wall Mounted Type
KAF952B42
REFNET headerDistributive piping
RSXQ8PY1 RSXQ10PY1 RSXQ12PY1
Auxiliary pipe set*1 KHFP22B16P
RSXQ14PY1 RSXQ16PY1 RSXQ18PY1
KHRP26M22H (Max. 4 branch)KHRP26M33H (Max. 8 branch)KHRP26M72H (Max. 8 branch)
KHRP26M22H (Max. 4 branch)KHRP26M33H (Max. 8 branch)
REFNET jointKHRP26A22TKHRP26A33TKHRP26A72T
KHRP26A22TKHRP26A33T
Type
Item
KHFP22B8P KHFP22B10P KHFP22B12P KHFP22B18P
Central drain pan kit KWC26C280 KWC26C450
Digital pressure gauge kit BHGP26A1
Specifications—Indoor UnitsOutdoor Units
for connection toresidential indoor unitsBP Units
Note: Filter is a standard accessory. It should be replaced approximately 3 years.
Note: A single BP unit does not require a REFNET joint. 2 BP units require only 1 REFNET joint, and 3 BP units require only 2 REFNET joints.
Note: *1. Auxiliary pipe sets are not attached to the outdoor units. If neccesary, use the optional accessories.
39
Control Systems
Individual Control Systems for VRV Indoor Units
Large buttons and arrow keys for easy operation.
Guide on display gives an explanation of each setting.
Backlight and dot matrix LCD display for easy viewing.
Weekly schedule timer can be set up easily.
10 display languages are available.(English, German, French, Spanish, Italian, Portuguese, Greek, Dutch, Russian and Turkish)
Wired remote controller (Option)
BRC1C62
BRC1E61
Displays current airflow, swing, temperature, operating mode and timer settings.
Outdoor unit
Indoor unit
Forced OFF input
Remote controllerRemote controller
Remote controllerRemote controller
Remote controllerRemote controller
Remote controller
Remote controller
Heat Reclaim Ventilator
The indoor unit can be connected by the two remote controller, for example one in the room and the other one in the control room, which can control the operation of indoor unit freely.(The last command has a priority.) Of course, the group control by two remote controller is also possible.
Control by two remote controller
The system can be expanded to add several controllers, such as BMS, Forced OFF input and etc.
Expansion of system control
One remote controller can control the operation of max.16 indoor units at the same time.
Group control
Equipment related to the central control
1 2 3
The wiring of remote controller can be extended to max. 500 m and it is possible to install the remote controllers for the different indoor units in one place.
Remote control
The operation of the Heat Reclaim Ventilator can be controlled by the remote controller of the indoor unit. Of course, the remote controller can display the time to clean the filter.
Control for the combined operation
44
3
2
1
Wide variation of remote controllers for indoor unitsThe wired remote controller supports a wide range of control functions
Navigation remote controller (Wired remote controller) (Option)
Wired remote controllerwith weekly schedule timer (Option)
BRC1D61
Adds weekly schedule timer function.
Notes: 1. Standard remote controllers (BRC1C62) not required.2. If the BRC1D61 is connected to the centralised remote controllers
(DCS303A51, DCS302CA61, DCS301BA61, DST301BA61), the schedule function is not available.
40
Wireless remote controller (Option)
Wired remote controller(BRC1C62)
Wired remote controller with weekly schedule timer
(BRC1D61)
Wireless remote controller*(Installed type signal receiver unit)
Wireless remote controller*(Separate type signal receiver unit)
Simplified remote controller(Exposed type)
(BRC2C51)
Simplified remote controller(Concealed type: for Hotel use)
(BRC3A61)
FXFQ FXZQ FXCQ FXDQ FXMQ FXHQ FXAQ FXL(N)QFXKQ
Wide variation of remote controllers for indoor unitsWide variation of remote controllers for VRV indoor units
*Refer to page 43 for the name of each model.
FXUQ
Signal receiver unit(Separate type)
Wireless remote controller
*Wireless remote controller and signal receiver unit are sold as a set. *Refer to page 43 for the name of each model.
Signal receiver unit(Installed type)
Signal receiver unit can be installed on the panel ex. Ceiling Mounted Cassette (Round Flow) type
The same operation modes and settings as with wired remote controllers are possible.
A compact signal receiver unit (separate type) to be mounted into a wall or ceiling is included.
• A signal receiver unit (installed type) for a Ceiling Mounted Cassette (Round Flow, Compact Multi Flow, Double Flow) type, Ceiling Suspended type and Wall Mounted type is mounted into the indoor unit.
The remote controller has centralised its frequently used operation selectors and switches (on/off, operation mode, temperature setting and airflow volume), making itself suitable for use in hotel rooms or conference rooms.
The exposed type remote controller is fitted with a thermostat sensor.
The concealed type remote controller smartly fits into a night table or console panel in a hotel room.
Exposed type(BRC2C51)
Concealed type(For hotel use)
(BRC3A61)
Simplified remote controller (Option)
Navigation remote controller(Wired remote controller)
(BRC1E61)
Control Systems
41
Up to 64 groups of indoor units (128 units) can be centrally controlled.
Optional controllers for centralised control can be combined freely, and
system can be designed in accordance with building scale and purpose.
System integration with various air-conditioning peripheral
equipment, such as a Heat Reclaim Ventilator, is easy.
Wiring can be run up to a total length of 2 km, and adapts easily to
large-scale system expansion.
Centralised Control Systems for VRV Indoor Units
Central control adaptor kit (DTA107A55)
Central remote controller(DCS302CA61)
Up to 2 units connectable
Unified on/off controller(DCS301BA61)
Connection of up to 8 unitspossible
Schedule timer (DST301BA61)1 unit connection possible ; 8 weekly schedule control patterns possible
Forced shut-down input
Independent and centralised control of a Heat Reclaim Ventilator is possible.
Unification adaptor for computerised control (DCS302A52)
Interlink Building Management System (host computer monitor panel) also possible
6 cores 7 cores max.
Address setting of central control can be performed from the remote controller.
Group control of up to 16 units is possible (group control via automatic address setting)
System without remote control is also available.
Interface adaptor for SkyAir series (built-in indoor unit) (DTA102A52)
Connectable number of centralised control equipment
Central remotecontroller 2 units
Unified on /offcontroller 8 units
Schedule timer 1 unit
Wiring adaptorfor other air-conditioners (DTA103A51)
For more details, please refer to the Engineering Data Book.
Outdoor-air processing unit can be connected.
• Certain indoor units limit the functions of some control systems.
Input (Lights)
Input (Key signal -General purpose ADP)
Dio UnitDEC102A51(Option)
Di UnitDEC101A51(Option)
System
Set temperature change command
OFFcommand
Pi Port
• Connection to power consumption metre when using power proportional distribution function. (Option)
RS-232C
Air Conditioning NetworkService System modemfor connections
• CSV output of power proportional distribution results (Option)
PCMCIAFlash
Memory
Remote monitor-ing and control
Mobile Phone PCD -NET Plus AdaptorDCS601A52 (Option)
Number of indoor units expanded from 64 to 128.
D -NET
Function 1
Function 2Function 3
Function 4
Function 5
Function 6
Indoor UnitHeat Reclaim Ventilator
ACC centre• Air Conditioning Network Service System (Optional Maintenance Service)
System Components
Via internet
DCS601C51
Malfunction reportby E-mail
Advanced Control Systems for VRV Indoor Units
42
Max. 16 groups of indoor units can be easily controlled with the large LCD panel.• Max. 16 groups (128 indoor units) controllable• Backlight and large LCD panel for easy readability• ON/OFF, temperature settings and scheduling can
be controlled individually for indoor units.
• Max. 16 groups (128 indoor units) controllable• 2 remote controllers can be used to control from 2
different places.• Operating status indication (Normal operation, Alarm)• Centralised control indication
• Max. 128 indoor units controllable• When used in combination with a central remote
controller, a maximum of 8 weekly schedule patterns can be set, while the central controller can be used to select desired zones. Up to 2 ON/OFF pairs can be set per day.
DCS303A51
DCS301BA61
DST301BA61
• Max. 64 groups (128 indoor units) controllable• Max. 128 groups (128 indoor units) are controllable by
using 2 central remote controllers, which can control from 2 different places.
• Zone control• Malfunction code display• Max. wiring length 1,000 m (Total: 2,000 m)• Connectable with Unified ON/OFF controller, schedule
timer and BMS system
DCS302CA61
* For residential use only. Cannot be used with other centralised control equipment.
Max. 128 indoor units can be operated as programmed schedule.
Schedule timer (Option)
Max. 16 groups of indoor units can be operated simultaneously/individually.
Unified ON/OFF controller (Option)
Max. 64 groups (zones) of indoor units can be controlled individually same as LCD Remote controller.
Central remote controller (Option)
Residential central remote controller* (Option)
• Max. 48 hours back up power supply• Max. wiring length 1,000 m (Total: 2,000 m)• Compact size casing (Thickness: 16 mm)• Connectable with Central Remote controller,
Unified ON/OFF controller and BMS system
• Max. wiring length 1,000 m (Total: 2,000 m)• Compact size casing (Thickness: 16 mm)• Connectable with Central Remote controller, • Schedule timer and BMS system
• Airflow volume and direction can be controlled individually for indoor units in each group operation.
• Ventilation volume and mode can be controlled for the Heat Reclaim Ventilator.
• Up to 4 ON/OFF pairs can be set per day by connecting a schedule timer.
• All indoor units can be turned on or off at once with “ALL” button.
• Each group has a dedicated button for convenience.• Outside temperature display
Support for centralised control from elsewhere using a PC with a Web browser (Option)Function 1
Sending of e-mail alerts to a specified address when malfunctions occur (Option)
Function 2
Built-in modem for connecting to Air Conditioning Network Service System (Option)
Function 3
Function 4
Management of facilities/equipment other than A/C units (By adding Dio unit or Di unit)
Function 5
Simple Interlock FunctionFunction 6
Doubling of number of connectable indoor units by adding a D -NET Plus Adaptor (Option)
• Colour LCD touch panel icon display• Small manageable size • Simplified engineering• Multi language (English, French, Italian, German, Spanish, Dutch,
Portuguese, Chinese and Korean)• Yearly schedule• PPD (Power Proportional Distribution function) (Option)• Auto heat/cool change-over• Temperature limitation• Enhanced history function • Air Conditioning Network Service System (Optional Maintenance Service)• Simple Interlock Function
Communication functions in the user-friendly icon-based multilingual controller simplify centralised control of the VRV system.
—— — DTA114A61 DTA114A61 DTA114A61
43
Operation Control System Optional Accessories
For VRV indoor unit use
For Residential indoor unit use
No. FXFQ-P FXCQ-M FXKQ-MA FXDQ-PBFXDQ-NB FXAQ-MA FXLQ-MA
FXNQ-MA
Remote controller
Type
Item
No. Type
Item
BRC7F635F BRC7C67 BRC4C63 BRC7EA619 BRC4C64BRC4C66
FXMQ-P
BRC4C66
FXUQ-MA
BRC7CA529W
FXHQ-MA
BRC7EA66
FXMQ-MA
BRC4C64
FXZQ-M
BRC7E531W1
BRC1C62
Wired remote controller with weekly schedule timer BRC1D613
Navigation remote controller (Wired remote controller) BRC1E612
Notes: 1. Installation box is necessary for each adaptor marked .2. Up to 2 adaptors can be fixed for each installation box.
4
5
Simplified remote controller (Exposed type)
6 Adaptor for wiring
7-1 Wiring adaptor for electrical appendices (1)
7-2 Wiring adaptor for electrical appendices (2)
Remote controller for hotel use (Concealed type)
8 Remote sensor (for indoor temperature)
10 External control adaptor for outdoor unit
—
— —
—
BRC3A61
BRC2C51
9 Installation box for adaptor PCB
BRC2C51
BRC3A61 —
—
5. Installation box is necessary for second adaptor.6. Installation box is necessary for each adaptor.
3. Only one installation box can be installed for each indoor unit.4. Up to 2 installation boxes can be installed for each indoor unit.
KRP1B61
DTA104A61
KRCS01-1B KRCS01-1B
KRP1C63
KRP2A61 KRP2A62
KRP4AA51 KRP4AA53
KRP2A61
KRP1B61
DTA104A62
Notes 2, 3KRP1B96
DTA104A62
Notes 4, 6KRP1BA101 —Note 3
KRP1CA93Notes 2, 3 KRP4AA93
Notes 2, 3KRP1H98
KRP1C64
KRP2A61 KRP2A61
KRP4AA51 KRP4AA51
KRP2A62 KRP2A61
KRP4AA52 KRP4AA51 KRP4AA51
Notes 2, 3KRP4A96— Notes 4, 6
KRP1BA101
DTA104A61
KRP2A62
—
KRP1BA97
KRP4AA53
—DTA104A53DTA104A61 DTA104A61 DTA104A62 DTA104A61 DTA104A61
KRP1BA57
KRP2A62
KRP4AA53
—KRP1BA54
—
KRP1B61KRP1B56
KRP2A53
KRP4A54
KRP1B61
KRP2A61
KRP4AA51
KRCS01-4B KRCS01-4B
11 Adaptor for multi tenant
Wired type
Wireless type
Option List
Control Systems
Note 3
KRP4AA53
KRP1B98
1 Remote controllerWired typeNote 1
Wireless type
BRC1C61
— Note 2
——
—
—
—
—
—
BRC7C613WNote 3
KRP1BA57
—
—
KRP1BA54
3 Wiring adaptor for electrical appendices
4 Installation box for adaptor PCB
Notes: 1. Wiring for wired remote controller should be obtained locally.2. A wireless remote controller is a standard accessory for FDKS and FTKS models.3. Installation box for adaptor PCB (KRP1B98) is necessary.4. Installation box for adaptor PCB (KRP1BA101) is necessary.5. Time clock and other devices should be obtained locally.
2Note 4
KRP1BA57Adaptor for wiring
BRC7E531W
Note 4
KRP4AA53 KRP4AA51
KRP1BA101KRCS01-1B5 Remote sensor (for indoor temperature)
FCQ-B FFQ-B FBQ-B FDKS-EAFDKS-C(A)
FTKS-DFTKS-F
7 Remote controller loss prevention chain KKF917A4
6Wiring adaptor for time clock/remote controller Note 5
(Normal open pulse contact/normal open contact) KRP413AB1S
44
System Configuration
•Up to 64 groups of indoor units(128 units) can be connected, and ON/OFF, temperature setting and monitoring can be accomplished individually or simultaneously. Connectable up to 2 controllers in one system.
Note 2
DCS302CA61Central remote controller2
•Up to 16 groups of indoor units (128 units) can be easily controlled using the large LCD panel. ON/OFF, temperature settings and scheduling can be controlled individually for indoor units.
Note 3
DCS303A51Residential central remote controller1
•Up to 16 groups of indoor units(128 units) can be turned, ON/OFF individually or simultaneously, and operation and malfunction can be displayed. Can be used in combination with up to 8 controllers.
Note 2
DCS301BA61Unified ON/OFF controller3
KJB212AAElectrical box with earth terminal (2 blocks)3-1
KEK26-1ANoise filter (for electromagnetic interface use only)3-2
KJB311AAElectrical box with earth terminal (3 blocks)2-1
DTA102A52Interface adaptor for SkyAir-series7
DTA107A558
DTA103A51Wiring adaptor for other air-conditioner9
No. Item Model No. Function
•Up to 1024 units can be centrally controlled in 64 different groups.
•Wiring restrictions (max. length: 1,000 m, total wiring length: 2,000 m, max. number of branches: 16) apply to each adaptor.
DTA109A51D -NET
Expander Adaptor10
•Fixing plate for DTA109A51KRP4A92Mounting plate10-1
•Adaptors required to connect products other than those of the VRV System to the high-speed DIII-NET communication system adopted for the VRV System.
* To use any of the above optional controllers, an appropriate adaptor must be installed on the product unit to be controlled.
For UAT(Y)-K(A),FD-K
For SkyAir, FD(Y)M-FA, FDY-KAFDYB-KA, FVY(P)J-A, FXUQ-MA
Central control adaptor kit
Notes: 1. Installation box for adaptor must be obtained locally. 2. For FXUQ-MAV1, an interface adaptor (DTA102A52) for the SkyAir series is necessary. For residential indoor units, an interface adaptor (KRP928BB2S or DTA112BA51) is required for each indoor unit.3. For residential use only. Cannot be used with other centralised control equipment.4. A wiring adaptor (KRP413AB1S) is also required for each indoor unit.
•Programmed time weekly schedule can be controlled by unified control for up to 64 groups of indoor units (128 units). Can turn units ON/OFF twice per day.
Note 2
DST301BA61Schedule timer4
KRP928BB2S
5-room centralised controllerfor residential indoor units5
DTA112BA51
Interface adaptor for residentialindoor units6
Building Management System
•Interface unit to allow communications between VRV and BMS. Operation and monitoring of air-conditioning systems through LONWORKS® communication.DMS504B514
3
•Expansion kit, installed on DMS502B51, to provide 2 more DIII-NET communication ports. Not usable independently.DAM411B513-1
•Enables ON/OFF command, operation and display of malfunction; can be used in combination with up to 4 units.DPF201A515
•Enables temperature measurement output for 4 groups; 0-5VDC.DPF201A526
•Enables temperature setting input for 16 groups; 0-5VDC.DPF201A537
No. Item Model No. Function
*2 Interface for use in LONWORKS®
•Interface unit to allow communications between VRV and BMS. Operation and monitoring of air-conditioning systems through BACnet® communication.DMS502B51*1 Interface for use in BACnet®
Optional DIII board
Con
tact
/ana
logu
esi
gnal
Parallel interfaceBasic unit
Temperaturemeasurement units
Temperaturesetting units
•Air conditioner management system that can be controlled by personal computers.
DAM602B51
KJB411A
DAM602B52
256 units
DAM602B51x2512 units
DAM602B51x3768 units
DAM602B51x41024 unitsintelligent Manager III
128 units
2Number of units to be connected
HardwareBasic
•Expansion kit, installed on DMS502B51, to provide 16 more wattmeter pulse input points. Not usable independently.
•External temperature sensor for intelligent Manager III.
DAM412B51
DAM101A51
Optional Di board
Optional DIII Ai unit2-4
•8 pairs based on a pair of On/Off input and abnormality input.DEC101A51Di unit2-5
3-2
1-1
1-4
1
Electrical box with earth terminal (4 blocks)
DCS601A521-1 •Additional 64 groups (10 outdoor units) is possible.
DCS004A511-3 •Monitors and controls the air conditioning system using the Internet and a Web browser application on a PC.
•Wall embedded switch box.
DCS601C51 •Air-Conditioning management system that can be controlled by a compact all-in-one unit.
Com
mun
icat
ion
line
Notes: *1. BACnet® is a registered trademark of American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).
*2. LONWORKS® is a trademark of Echelon Corporation registered in the United States and other countries. *3. Installation box for adaptor must be obtained locally.
DCS002C511-2
intelligent Touch
Controller
DIII-NET plus adaptor
Web
intelligent Touch Controller
PPD
Hardware
Hardware
Software
Basic
Option •PPD: Power Proportional Distribution function
•4 pairs based on a pair of On/Off input and abnormality input.DEC102A51Dio unit2-6
2-1
2-2
2-3
•Power Proportional Distribution functionDAM002A51
Option Software
2-1
•Monitors and controls the air conditioning system using the Internet and a Web browser application on a PC.DAM004A512-2
•ECONO (Energy saving functions.)DAM003A51
PPD
Web
ECONO2-3
•Interface between the central monitoring board and central control units.DCS302A528 Unification adaptor forcomputerised control
For FCQ-B, FFQ-B, FBQ-B
For FTKS-D/F, FDKS-EA/C(A)
•Up to 5 indoor units can be controlled. This is a low cost system which can only control ON/OFF.Note 4
KRC72For FTKS-D/F, FDKS-EA/C(A)
Memo
1. Air conditioners should not be installed in area s where corrosiv e gas es, suc h as acid gas or alkalin e gas, are produced.2. If the outdoor unit is to be installed close to the se a shore, direct exposure to the sea breeze should be avoide d. If you need to install the outdoor unit close to the sea shore, contact your local distributor.
Cautions on product corrosion
Warning Daiki n products are manufactured for export to numerous countries throughout the world. P rior to purchas e, please confirm with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standar ds, and is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify the application of any loca l legis lation.
Ask a qualified installer or contractor to install this product. Do not try to install the product yourse lf. Improper installation can result in water or refrigera nt leakage, electrical shoc k, fire or explosion.
Us e only those parts and accessories supplied or specified by Da ikin. A sk a qualified installer or contractor to install those parts and accessorie s . Use of unauthorised parts and accessorie s or improper installation of parts and accessories ca n result in water or refrigera nt leakage, electrical shock, fire or explosion.
Rea d the User's Manua l carefully before using this product. The User's Manua l provides important safety instructions and warnings. B e sure to follow these instructions and warnings.
If you have any enquiries , pleas e contact your local importer, distributor and/or retailer.
JMI-0107 JQA-1452
Organization:DAIKIN INDUSTRIES, LTD.AIR CONDITIONING MANUFACTURING DIVISION
Scope of Registration:THE DESIGN/DEVELOPMENT AND MANUFACTURE OF COMMERCIAL AIR CONDITIONING, HEATING, COOLING, REFRIGERATING EQUIPMENT, HEATING EQUIPMENT, RESIDENTIAL AIR CONDITIONING EQUIPMENT, HEAT RECLAIM VENTILATION, AIR CLEANING EQUIPMENT, COMPRESSORS AND VALVES.
Organization:DAIKIN INDUSTRIES(THAILAND) LTD.
Scope of Registration:THE DESIGN/DEVELOPMENTAND MANUFACTURE OF AIR CONDITIONERS AND THE COMPONENTS INCLUDING COMPRESSORS USED FOR THEM
All of the Daikin Group’s business facilities and subsidiaries in Japan
international standard for environment management.
All rights reservedPrinted in Vietnam 07/12/001 VK
HEAD OFFICE
HNÍHC GNØOHP NÊAV
IÄON ØAH HNÙAHN IHC
GNÜAN ØAÑ HNÙAHN IHC
MIK TÄEIV NÀAHP ÅOC YT GNÂOCUmeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan
MCH.PT ,3.Q ,4.P ,8 gnùahT gnïaM hcùaC 302-102 ,ÙA maN øahn aøot ,51-41 gnàaTTel: (08) 62 504 888 Fax: (08) 62 504 999
Tel: (04) 35 657 677 Fax: (04) 35 657 688
Tel: (0511) 362 4250 Fax: (0511) 362 4251
www.daik in .com.vn
iäoN øaH ,aÑ gnáoÑ näauQ ,hnA yuD oøaÑ 1 ,rewoT kraP naecO øahn aøot ,21 gnàaT
gnüaN øaÑ .PT ,uâahC iûaH .Q ,céaB gnøôöC aøoH .P ,4/03 gnøôöÑ ,1.2A âoL ,21 gnàaT
iáohp nâahp ùyl iïaÑ
Miễn phí cöôùc cuoäc goïi
TRUNG TÂMDICH VU KHÁCH HÀNG