22w w w . a d c . c o m + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 1 - 8 0 0 - 3 6 6 - 3 8 9 1
Fiber ConnectivityIntrafacility Fiber Cable (IFC) Assemblies
Intrafacility fiber cable (IFC) is a multifiber cable designed for use within a building. The number of fibersrange from 12 to 144. Standard IFC assemblies are riser rated and meet UL-1666 OFNR. Two types ofIFC are available: stranded and ribbon.
With stranded cable, individual 900 m fibers make up the construction of the cable. The fibers are
bundled into subunits of 6- or 12-fibers each.
Detail A
Buffered
Fiber
Aramid Yarn
PVC Jacket
See
Detail C
Ripcord (2)
6-Fiber Subunit(See Detail A)
Mylar Tape
PVC CableJacket
Central StrengthMembers
24-Fibers with 6-Fiber Subunits
Aramid
Yarn
Buffered
Fiber
Detail B
See
Detail C
PVC Jacket
Ripcord (2)
12-Fiber Subunit(See Detail B)
MylarTape
PVC CableJacket
CentralStrengthMembers
72-Fibers with 12-Fiber Subunits
Coating
Cladding
Core
Buffered Fiber
Buffer
Detail CPVC Jacket
Buffered Fiber900 m
Aramid Yarn
12-Fibers Shown
Ribbon cable consists of multi-fibers arranged in ribbons. Each ribbon contains 12-fibers and isidentified as a subunit. The fibers which comprise the ribbons are color-coded for identification. Withthe construction of ribbon cable, the fibers are located in the center of the cable and the outer jacket
provides the strength and protection of the cable.
SeeDetail A
PVC InnerJacket
PVC OuterJacket
FiberglassStrengthMembers
MylarTape
RibbonAir Core
Coating
Cladding
Core
Jacket Detail Fiber Color-Code Chart
1 Blue 5 Slate 9 Yellow
2 Orange 6 White 10 Violet
3 Green 7 Red 11 Rose
4 Brown 8 Black 12 Aqua
8/10/2019 VEN15-ADCTELE00033_22_23.pdf
2/2
3
/0
9
1
0
6
6
2
0
A
E
Da
ta
Connectivi
ty
Solutions
23w w w . a d c . c o m + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 1 - 8 0 0 - 3 6 6 - 3 8 9 1
Fiber ConnectivityIntrafacility Fiber Cable (IFC) Assemblies
Connector #1 Type
Singlemode
0 Stub (only on 2nd end)
7 SC ultra polish
K LC ultra polish
Multimode
9 SC
P LC
Catalog Number
___ __ /__ __ __ __ __ __
Assembly Length for
Connector to Stub
016 16 m (50')
023 23 m (75')
031 31 m (100')
046 46 m (150')
061 61 m (200')
077 77 m (250')
092 92 m (300')
122 122 m (400')
153 153 m (500')
Assembly Length for
Connectors on Both Ends2
XXX Length in meters
Example: 010 = 10 meters
125 = 125 meters
Breakout/Panel Type1
LEAVEBLANK
8" FCM
2A FL2, 12 exit up or down
2B FL2, 24 exit up or down
2C FL2, 48 exit up or down
2D FL2, 72 exit up
2E FL2, 96 exit up
2F FL2, 72 exit down
2G FL2, 96 exit down
NGF NGF, 96- and 144-position
LA LSX, 72- and 96-position
(singlemode only)
TFP TFP Panel
1For competitors panelproducts, ADC recommendsusing the FCM breakout
length (1.8 m = 6').2Standard lengths for
connectors on both endsup to 150 meters.
Additional ber counts,
lengths and connector styles
are available upon request.
Please contact ADC Technical
Assistance Center.
Cable Type
Singlemode
A 12-ber stranded
B 24-ber stranded
2 48-ber stranded
V72-ber stranded
L 96-ber stranded
EH 144-ber stranded
NA 12-ber ribbon
HA 24-ber ribbon
JA 48-ber ribbon
DS 72-ber ribbon
LA 96-ber ribbon
LH 144-ber ribbon
Multimode
AD 24-fiber stranded 50/125 m
DH 48-fiber stranded 50/125 m
VA 72-fiber stranded 50/125 m
WT 96-fiber stranded 50/125 m
VZ 144-fiber stranded 50/125 m
VE 72-fiber stranded plenum laser optimized
to 300 m, 50/125 m (aqua)
FZ 144-fiber stranded plenum laser optimized
to 300 m, 50/125 m (aqua)
Cable Type
IFC Singlemode Multiber
Patch cords (4-24 bers)
MIFC Multimode Multiber
Patch cords (6-12 bers)
Connector #2 Type
Singlemode Multimode0 Stub (only on
2nd end)
0 Stub
7 SC ultra polish 9 SC
K LC ultra polish P LC