Post on 19-May-2020
Key features at a glance
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-0 Festo AG & Co.
M-series service unitsCompressed air preparation
M-series service units – Manual condensate drain
– Automatic condensate drain
-V- New
Soft-start valve
HEMS
– Individual compressed air
preparation
– Modular and flexible
– A complete series of service units
for compressed air preparation, in
three sizes M1, M2 and M3
– The individual service units can be
combined with one another
Festo provides the M series with a
comprehensive accessory range:
– Mounting brackets
– Connectors
– Piping connectors
– Regulator adjustment locks
– Pressure gauges
– Pressure switches
Accessories� Vol.3 / 10.2-72
10.2
Key features at a glance
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-1Festo AG & Co.
M-series service unitsCompressed air preparation
Individual units
1 Piping connector LVR-M
2 Manual on-off valve
3 Compressed air filter/regulator LFR-M
4 Mounting bracket HW-M
5 Connector LV-M
6 Branching module FRM-M
7 Lubricator LOE-M
8 Pressure regulator LR-M
9 Soft-start valve HEM-M
aJ Pressure switch PEV
and double nipple ESK-�-�
The series is characterised by its many
variants:
– 4 pressure ranges:
4, 7, 10 and 16 bar
– Grade of filtration 40, 5, 1 and
0.01 µm
– Active carbon filter
– 5 connection sizes: G�, G�, G�,
G� , G�
– Bowl types
– Plastic without drain
– Plastic with manual drain
– Plastic with automatic drain
– Metal without drain
– Metal with manual drain
– Metal with automatic drain
– Plastic bowl with bowl guard
(standard)
1
2
3
4
5
6
8
7
69
aJ
Sizes M1 M2 M3
es
G�
nsizes
G�
ection G�
onnec
G�
Co G�
10.2
Type code
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-2 Festo AG & Co.
M-series service unitsCompressed air preparation
Function
LR Pressure regulator
LRB Pressure regulator for mani-
fold assembly
LF Compressed air filter
LFM Fine and micro filters
LFR Compressed air filter and
regulator
LOE Compressed air lubricator
FRC Compressed air service unit
HEA Manual on-off valve (flow from
left to right)
HEB Manual on-off valve (flow from
right to left)
HEL Soft-start valve
HEM Soft-start valve with dump
function and quick exhaust
HEMS Soft-start valve without
manual override
FRM Branching module
LD Membrane air dryer
Series
M = Modular
Size
1 = Size 1
2 = Size 2
3 = Size 3
Thread type
G = G thread
N = NPT thread
Connection size
� = G�
� = G�
� = G�
� = G�
� = G�
M– ––
10.2
Type code
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-3Festo AG & Co.
M-series service unitsCompressed air preparation
Options
G = With pressure gauge
I = Return flow
K = Without secondary venting
Y = PEV-�-B
Z = PEV-�-SC-OD with display
000 = Pneumatic actuation
024 = 24 V DC
110 = 110 V AC
230 = 230 V AC
1 = Cartridge size 1
2 = Cartridge size 2
3 = Cartridge size 3
4 = Cartridge size 4
Bowls
P = Plastic/without drain
R = Plastic/manual drain
S = Plastic/automatic drain
Q = Metal/without drain
T = Metal/manual drain with sight
glass
U = Metal/automatic drain with
sight glass
Pressure regulation range
04 = 0 ... 4 bar
07 = 0 ... 7 bar
10 = 0 ... 10 bar
16 = 0 ... 16 bar
Grade of filtration
A = 0.01 µm
B = 1 µm
C = 5 µm
E = 40 µm
X = Active carbon filter
Exceptions� individual units
Dew point
STD = Standard –40 °C
ECO = Economy –20 °C
10.2
Product range overview
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-4 Festo AG & Co.
M-series service unitsCompressed air preparation
Connection Grade of filtration Pressure regulation range Dew point
* Delivery time approx. 5 weeks
** Not for versions with plastic bowls
*** Not for versions with automatic conden-
sate drain G�
G�
G�
G�
G�
NPT�
...1
0.01µm
1µm
5µm
40µm
Active
carbon
filter
0–4bar
0–7bar
0–10bar
0–16bar
Standard
–20°C
(–40°C)
Econom
y–20°C
Designation
Type
Size � � � � � N A B C E X 04 07 10 16 STD ECO
Pressure regulators 1 – – – * – – – – – – – –g
LR-... 2 – – * – – – – – – –
� Vol.3 / 10.2-6 3 – – * – – – – – * – –
Pressure regulators
LRB-1 – – – – * – – – – – – – –
LRB-...
� Vol.3 / 10.2-6 2 – – – – * – – – – – – –
Filters 1 – – – * – – – – – – – – –
LF-... 2 – – * – – – – – – – – –
� Vol.3 / 10.2-6 3 – – * – – – – – – – – –
Fine/micro filters 1 – – – – * – – *** – – – – – –/
LFM-... 2 – – * – – *** – – – – – –
� Vol.3 / 10.2-7 3 – – * – – *** – – – – – –
Filter regulators 1 – – – * – – – * – – –g
LFR-... 2 – – * – – – * ** – –
� Vol.3 / 10.2-7 3 – – * – – – * ** – –
Lubricator 1 – – – * – – – – – – – – – – –
LOE-... 2 – – * – – – – – – – – – – –
� Vol.3 / 10.2-8 3 – – * – – – – – – – – – – –
Service unit 1 – – – * – – – * – – –
FRC-... 2 – – * – – – * ** – –
� Vol.3 / 10.2-8 3 – – * – – – * ** – –
Manual on-off valves 1 – – – * – – – – – – – – – – –
HEA-... 2 – – * – – – – – – – – – – –
� Vol.3 / 10.2-9 3 – – * – – – – – – – – – – –
Manual on-off valves
HEB-2 – – * – – – – – – – – – – –
HEB-...
� Vol.3 / 10.2-9 3 – – * – – – – – – – – – – –
Soft-start valves
HEM(S)-2 – – * – – – – – – – – –
HEM(S)-...
� Vol.3 / 10.2-9 3 – – * – – – – – – – – –
Soft-start valves
HEL-2 – – * – – – – – – – – – –
HEL-...
� Vol.3 / 10.2-10 3 – – * – – – – – – – – – –
Branching module 1 – – – – * – – – – – – – – – – –g
FRM-... 2 – – – – * – – – – – – – – – – –
� Vol.3 / 10.2-10 3 – – – – * – – – – – – – – – – –
Membrane air dryer
LD-...
� Vol.3 / 10.2-10
3 – – – – * – – – – – – – – –
Service unit combinations
LFR FRC1 – – – – * – – – – – – – – –
LFR-..., FRC-...
� starting on2 – – – * – – – – – – – – –
� starting on
Vol.3 / 10.2-11 3 – – – – * – – – – – – – – –
10.2
Product range overview
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-5Festo AG & Co.
M-series service unitsCompressed air preparation
Bowls Options
Plastic
withoutdrain
Metal
withoutdrain
Plastic
manualdrain
Plastic
automaticdrain
Metal
manualdrain
Metal
automaticdrain
Withpressuregauge
Withoutpressuregauge
Returnflow
Withoutsecondary
venting
Pressureswitch
type:PEV-�
B
Pressureswitch
with
displayPEV-�-SC-OD
Pneumaticactuation
24VDC
110VAC
230AC
Withoutmanual
override
Cartridgesize1
Cartridgesize2
Cartridgesize3
Cartridgesize4
P Q R S T U G I K Y Z 000 024 110 230 1 2 3 4
– – – – – – * * – – – – – – – – – – –
– – – – – – * * – – – – – – – – – – –
– – – – – – * * – – – – – – – – – – –
– – – – – – – – * – – – – – – – – – – –
– – – – – – – – * – – – – – – – – – – –
– – – – – – – – – – – – – – – – –
– – – – – – – – – – – – – – – – –
– – – – – – – – – – – – – – – – –
– – – – – – – – – – – – – – – – –
– – – – – – – – – – – – – – – – –
– – – – – – – – – – – – – – – – –
– – – * – – – – – – – – – – –
– – – * – – – – – – – – – – –
– – – * – – – – – – – – – – –
– – – – – – – – – – – – – – – – – – –
– – – – – – – – – – – – – – – – – – –
– – – – – – – – – – – – – – – – – – –
– – – * – – – – – – – – – – –
– – – * – – – – – – – – – – –
– – – * – – – – – – – – – – –
– – – – – – – – – – – – – – – – – – – – –
– – – – – – – – – – – – – – – – – – – – –
– – – – – – – – – – – – – – – – – – – – –
– – – – – – – – – – – – – – – – – – – – –
– – – – – – – – – – – – – – – – – – – – –
– – – – – – – – – – – – – (S) – – – –
– – – – – – – – – – – – – (S) – – – –
– – – – – – – – – – – – – – – – – – – –
– – – – – – – – – – – – – – – – – – – –
– – – – – – – – – – – – – – – – – – –
– – – – – – – – – – – – – – – – – – –
– – – – – – – – – – – – – – – – – – –
– – – – – – – – – – – – – – – – –
– – – – – – – – – – – – – – – – –
– – – – – – – – – – – – – – – – –
– – – – – – – – – – – – – – – – –
10.2
Overview and ordering data
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-6 Festo AG & Co.
Pressure regulators/filters LR/LRB/LFM-series service units
Size Connection
M1 G�
G�
Pressure regulator
LR
with detenting regulator knob
Pressure regulator
LRB
with detenting regulator knob
Filter
LF
G�
Pressure regulation range up to 10 bar Grade of filtration 40 µm and 5 µmM2 G� Without pressure gauge Manual condensate drain
G�
G�
M3 G�
G�
G�
178 703 LR-M1-G�-10
178 727 LR-M1-G�-10
178 751 LR-M2-G�-10
178 783 LR-M2-G�-10
178 815 LR-M2-G�-10
178 847 LR-M3-G�-10
178 879 LR-M3-G�-10
178 911 LR-M3-G�-10
182 938 LRB-M1-G�-10
182 944 LRB-M2-G�-10
182 627 LF-M1-G�-ER
182 635 LF-M1-G�-ER
182 643 LF-M2-G�-ER
182 651 LF-M2-G�-ER
182 659 LF-M2-G�-ER
182 667 LF-M3-G�-ER
182 675 LF-M3-G�-ER
182 683 LF-M3-G�-ER
With pressure gauge Automatic condensate drain
178 704 LR-M1-G�-10G
178 728 LR-M1-G�-10G
178 752 LR-M2-G�-10G
178 784 LR-M2-G�-10G
178 816 LR-M2-G�-10G
178 848 LR-M3-G�-10G
178 880 LR-M3-G�-10G
178 912 LR-M3-G�-10G
182 628 LF-M1-G�-ES
182 636 LF-M1-G�-ES
182 644 LF-M2-G�-ES
182 652 LF-M2-G�-ES
182 660 LF-M2-G�-ES
182 668 LF-M3-G�-ES
182 676 LF-M3-G�-ES
182 684 LF-M3-G�-ES
Pressure regulation range up to 7 bar Filter cartridge 5 µm
With pressure gauge Without pressure gauge Manual condensate drain
178 696 LR-M1-G�-07G
178 720 LR-M1-G�-07G
178 744 LR-M2-G�-07G
178 776 LR-M2-G�-07G
178 808 LR-M2-G�-07G
178 840 LR-M3-G�-07G
178 872 LR-M3-G�-07G
178 904 LR-M3-G�-07G
182 937 LRB-M1-G�-07
182 943 LRB-M2-G�-07
182 623 LF-M1-G�-CR
182 631 LF-M1-G�-CR
182 639 LF-M2-G�-CR
182 647 LF-M2-G�-CR
182 655 LF-M2-G�-CR
182 663 LF-M3-G�-CR
182 671 LF-M3-G�-CR
182 679 LF-M3-G�-CR
Without pressure gauge Automatic condensate drain
178 695 LR-M1-G�-07
178 719 LR-M1-G�-07
178 743 LR-M2-G�-07
178 775 LR-M2-G�-07
178 807 LR-M2-G�-07
178 839 LR-M3-G�-07
178 871 LR-M3-G�-07
178 903 LR-M3-G�-07
182 624 LF-M1-G�-CS
182 632 LF-M1-G�-CS
182 640 LF-M2-G�-CS
182 648 LF-M2-G�-CS
182 656 LF-M2-G�-CS
182 664 LF-M3-G�-CS
182 672 LF-M3-G�-CS
182 680 LF-M3-G�-CS
Technical data/dimensions
� starting on Vol.3 / 10.2-16
Technical data/dimensions
� starting on Vol.3 / 10.2-20
Technical data/dimensions
� starting on Vol.3 / 10.2-24
Mounting accessories Pressure gauge� Vol.3 / 10.2-74 Filter cartridge 40 µm and 5 µm
Pressure sensor� Vol.3 / 10.2-80
g µ µ
� Vol.3 / 10.2-75
Mounting brackets, connectors, piping connectors, adjustment locks,
mounting nuts� starting on Vol.3 / 10.2-72
Mounting brackets, connectors,
piping connectors
� starting on Vol.3 / 10.2-72
10.2
Overview and ordering data
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-7Festo AG & Co.
Fine/micro filters and pressure regulators LFM/LFRM-series service units
Fine and micro filter
LFM
Filter regulator
LFR
with detenting regulator knob
Size Connection
M1 G�
G�G�
Pressure regulation range up to 10 bar
Fine filter 1 µm Grade of filtration 40 µm Grade of filtration 5 µm M2 G�
With pressure gauge G�
Manual condensate drain G�
182 751 LFM-M1-G�-BR
182 759 LFM-M2-G�-BR
182 771 LFM-M2-G�-BR
182 783 LFM-M2-G�-BR
182 795 LFM-M3-G�-BR
182 807 LFM-M3-G�-BR
182 819 LFM-M3-G�-BR
179 211 LFR-M1-G�-E10RG
179 307 LFR-M1-G�-E10RG
179 409 LFR-M2-G�-E10RG
179 521 LFR-M2-G�-E10RG
179 633 LFR-M2-G�-E10RG
179 745 LFR-M3-G�-E10RG
179 857 LFR-M3-G�-E10RG
179 969 LFR-M3-G�-E10RG
179 199 LFR-M1-G�-C10RG
179 295 LFR-M1-G�-C10RG
179 395 LFR-M2-G�-C10RG
179 507 LFR-M2-G�-C10RG
179 619 LFR-M2-G�-C10RG
179 731 LFR-M3-G�-C10RG
179 843 LFR-M3-G�-C10RG
179 955 LFR-M3-G�-C10RG
M3 G�
G�
G�
Automatic condensate drain
182 752 LFM-M1-G�-BS
182 760 LFM-M2-G�-BS
182 772 LFM-M2-G�-BS
182 784 LFM-M2-G�-BS
182 796 LFM-M3-G�-BS
182 808 LFM-M3-G�-BS
182 820 LFM-M3-G�-BS
179 212 LFR-M1-G�-E10SG
179 308 LFR-M1-G�-E10SG
179 410 LFR-M2-G�-E10SG
179 522 LFR-M2-G�-E10SG
179 634 LFR-M2-G�-E10SG
179 746 LFR-M3-G�-E10SG
179 858 LFR-M3-G�-E10SG
179 970 LFR-M3-G�-E10SG
179 200 LFR-M1-G�-C10SG
179 296 LFR-M1-G�-C10SG
179 396 LFR-M2-G�-C10SG
179 508 LFR-M2-G�-C10SG
179 620 LFR-M2-G�-C10SG
179 732 LFR-M3-G�-C10SG
179 844 LFR-M3-G�-C10SG
179 956 LFR-M3-G�-C10SG
Pressure regulation range up to 7 bar
Micro filter 0.01 µm Grade of filtration 40 µm or 5 µm Grade of filtration 5 µm
With pressure gauge
Manual condensate drain
183 769 LFM-M1-G�-AR
182 755 LFM-M2-G�-AR
182 767 LFM-M2-G�-AR
182 779 LFM-M2-G�-AR
182 791 LFM-M3-G�-AR
182 803 LFM-M3-G�-AR
182 815 LFM-M3-G�-AR
179 207 LFR-M1-G�-E07RG
179 303 LFR-M1-G�-E07RG
179 405 LFR-M2-G�-E07RG
179 517 LFR-M2-G�-E07RG
179 629 LFR-M2-G�-E07RG
179 741 LFR-M3-G�-E07RG
179 853 LFR-M3-G�-E07RG
179 965 LFR-M3-G�-E07RG
179 195 LFR-M1-G�-C07RG
179 291 LFR-M1-G�-C07RG
179 391 LFR-M2-G�-C07RG
179 503 LFR-M2-G�-C07RG
179 615 LFR-M2-G�-C07RG
179 727 LFR-M3-G�-C07RG
179 839 LFR-M3-G�-C07RG
179 951 LFR-M3-G�-C07RG
Automatic condensate drain
183 770 LFM-M1-G�-AS
182 756 LFM-M2-G�-AS
182 768 LFM-M2-G�-AS
182 780 LFM-M2-G�-AS
182 792 LFM-M3-G�-AS
182 804 LFM-M3-G�-AS
182 816 LFM-M3-G�-AS
179 208 LFR-M1-G�-E07SG
179 304 LFR-M1-G�-E07SG
179 406 LFR-M2-G�-E07SG
179 518 LFR-M2-G�-E07SG
179 630 LFR-M2-G�-E07SG
179 742 LFR-M3-G�-E07SG
179 854 LFR-M3-G�-E07SG
179 966 LFR-M3-G�-E07SG
179 196 LFR-M1-G�-C07SG
179 292 LFR-M1-G�-C07SG
179 392 LFR-M2-G�-C07SG
179 504 LFR-M2-G�-C07SG
179 616 LFR-M2-G�-C07SG
179 728 LFR-M3-G�-C07SG
179 840 LFR-M3-G�-C07SG
179 952 LFR-M3-G�-C07SG
Technical data/dimensions
� starting on Vol.3 / 10.2-28
Technical data/dimensions� starting on Vol.3 / 10.2-32
Mounting accessories
Filter cartridge 1 µm and 0.01 µm Pressure gauge� Vol.3 / 10.2-74g µ µ
� starting on Vol.3 / 10.2-75 Pressure sensor� Vol.3 / 10.2-80
Mounting brackets, connectors,
piping connectors
� starting on Vol.3 / 10.2-72
Mounting brackets, connectors, piping connectors, adjustment locks,
mounting nuts, filter cartridges� starting on Vol.3 / 10.2-72
10.2
Overview and ordering data
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-8 Festo AG & Co.
Lubricators/service units LOE/FRCM-series service units
Size Connection
M1 G�
G�
Lubricator
LOE
Service unit
FRC
with detenting regulator knob, including mounting bracket
M2 G� Operating pressure 12 bar Pressure regulation range 10 barG� Direct proportional lubricator Grade of filtration 40 µm Grade of filtration 5 µmG� With pressure gauge
Manual condensate drainM3 G�
G�
G�
182 904 LOE-M1-G�-P
182 906 LOE-M1-G�-P
182 908 LOE-M2-G�-P
182 910 LOE-M2-G�-P
182 912 LOE-M2-G�-P
182 914 LOE-M3-G�-P
182 916 LOE-M3-G�-P
182 918 LOE-M3-G�-P
180 939 FRC-M1-G�-E10RG
181 035 FRC-M1-G�-E10RG
181 137 FRC-M2-G�-E10RG
181 249 FRC-M2-G-�E10RG
181 361 FRC-M2-G�-E10RG
181 473 FRC-M3-G�-E10RG
181 585 FRC-M3-G�-E10RG
181 697 FRC-M3-G�-E10RG
180 927 FRC-M1-G�-C10RG
181 023 FRC-M1-G�-C10RG
181 123 FRC-M2-G�-C10RG
181 235 FRC-M2-G-�C10RG
181 347 FRC-M2-G�-C10RG
181 459 FRC-M3-G�-C10RG
181 571 FRC-M3-G�-C10RG
181 683 FRC-M3-G�-C10RG�
Automatic condensate drain
180 940 FRC-M1-G�-E10SG
181 036 FRC-M1-G�-E10SG
181 138 FRC-M2-G�-E10SG
181 250 FRC-M2-G�-E10SG
181 362 FRC-M2-G�-E10SG
181 474 FRC-M3-G�-E10SG
181 586 FRC-M3-G�-E10SG
181 698 FRC-M3-G�-E10SG
180 928 FRC-M1-G�-C10SG
181 024 FRC-M1-G�-C10SG
181 124 FRC-M2-G�-C10SG
181 236 FRC-M2-G�-C10SG
181 348 FRC-M2-G�-C10SG
181 460 FRC-M3-G�-C10SG
181 572 FRC-M3-G�-C10SG
181 684 FRC-M3-G�-C10SG
Working pressure 7 bar
Filter cartridge 40µm Filter cartridge 5µm
With pressure gauge
Manual condensate drain
180 935 FRC-M1-G�-E07RG
181 031 FRC-M1-G�-E07RG
181 133 FRC-M2-G�-E07RG
181 245 FRC-M2-G�-E07RG
181 357 FRC-M2-G�-E07RG
181 469 FRC-M3-G�-E07RG
181 581 FRC-M3-G�-E07RG
181 693 FRC-M3-G�-E07RG
180 923 FRC-M1-G�-C07RG
181 019 FRC-M1-G�-C07RG
181 119 FRC-M2-G�-C07RG
181 231 FRC-M2-G�-C07RG
181 343 FRC-M2-G�-C07RG
181 455 FRC-M3-G�-C07RG
181 567 FRC-M3-G�-C07RG
181 679 FRC-M3-G�-C07RG
Automatic condensate drain
180 936 FRC-M1-G�-E07SG
181 032 FRC-M1-G�-E07SG
181 134 FRC-M2-G�-E07SG
181 246 FRC-M1-G�-E07SG
181 358 FRC-M2-G�-E07SG
181 470 FRC-M1-G�-E07SG
181 582 FRC-M3-G�-E07SG
181 694 FRC-M3-G�-E07SG
180 924 FRC-M1-G�-C07SG
181 020 FRC-M1-G�-C07SG
181 120 FRC-M2-G�-C07SG
181 232 FRC-M1-G�-C07SG
181 344 FRC-M2-G�-C07SG
181 456 FRC-M1-G�-C07SG
181 568 FRC-M3-G�-C07SG
181 680 FRC-M3-G�-C07SG
Technical data/dimensions
� starting on Vol.3 / 10.2-36
Technical data/dimensions� starting on Vol.3 / 10.2-40
Mounting accessories Mounting brackets, connectors,
piping connectors, lubricator
protective covers
Mounting brackets, connectors, piping connectors, adjustment locks,
mounting nuts, filter cartridges, lubricator protective covers
� starting on Vol.3 / 10.2-72p
� starting on Vol.3 / 10.2-72 Pressure gauge� Vol.3 / 10.2-74� starting on Vol.3 / 10.2 72
Pressure sensor� Vol.3 / 10.2-80
10.2
Overview and ordering data
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-9Festo AG & Co.
Manual on-off valves/soft-start valves HEA/HEB/HEM/HEMSM-series service units
Manual on-off valve
HEA/HEB
Soft-start valve
HEM
with solenoid coil, without plug socket
Soft-start valve
HEMS
with solenoid coil, without plug
socket, without manual override
Size Connection
M1 G�
G�
Operating pressure 12 bar Pressure range 2 ... 10 bar Pressure range 2 ... 16 bar M2 G�
Direction of flow from left to right Voltage 24 V DC G�
183 001 HEA-M1-G�
183 002 HEA-M1-G�
183 003 HEA-M2-G�
183 004 HEA-M2-G�
183 005 HEA-M2-G�
183 006 HEA-M3-G�
183 007 HEA-M3-G�
183 008 HEA-M3-G�
183 039 HEM-M2-G�-10024
183 042 HEM-M2-G�-10024
183 045 HEM-M2-G�-10024
183 048 HEM-M3-G�-10024
183 051 HEM-M3-G�-10024
183 054 HEM-M3-G�-10024
193 701 HEMS-M2-G�-16024
193 704 HEMS-M2-G�-16024
193 707 HEMS-M2-G�-16024
193 710 HEMS-M3-G�-16024
193 713 HEMS-M3-G�-16024
193 716 HEMS-M3-G�-16024
G�
M3 G�
G�
G�
Direction of flow from right to left Voltage 110 V AC
183 009 HEB-M2-G�
183 010 HEB-M2-G�
183 011 HEB-M2-G�
183 012 HEB-M3-G�
183 013 HEB-M3-G�
183 014 HEB-M3-G�
183 040 HEM-M2-G�-10110
183 043 HEM-M2-G�-10110
183 046 HEM-M2-G�-10110
183 049 HEM-M3-G�-10110
183 052 HEM-M3-G�-10110
183 055 HEM-M3-G�-10110
193 702 HEMS-M2-G�-16110
193 705 HEMS-M2-G�-16110
193 708 HEMS-M2-G�-16110
193 711 HEMS-M3-G�-16110
193 714 HEMS-M3-G�-16110
193 717 HEMS-M3-G�-16110183 014 HEB M3 G�Voltage 230 V AC
183 041 HEM-M2-G�-10230
183 044 HEM-M2-G�-10230
183 047 HEM-M2-G�-10230
183 050 HEM-M3-G�-10230
183 053 HEM-M3-G�-10230
183 056 HEM-M3-G�-10230
193 703 HEMS-M2-G�-16230
193 706 HEMS-M2-G�-16230
193 709 HEMS-M2-G�-16230
193 712 HEMS-M3-G�-16230
193 715 HEMS-M3-G�-16230
193 718 HEMS-M3-G�-16230
Technical data/dimensions
� starting on Vol.3 / 10.2-44
Technical data/dimensions� starting on Vol.3 / 10.2-48
Mounting brackets, connectors,
piping connectors
Mounting brackets, connectors, piping connectors
� starting on Vol.3 / 10.2-72
Mounting accessories
p p g
� starting on Vol.3 / 10.2-72 Standard plug socketg /
34 583 MSSD-C
Plug socket with cable
30 931 KMC-1-24-2,5-LED
30 933 KMC-1-24-5-LED
30 932 KMC-1-220/230-2,5
30 934 KMC-1-220/230-5
10.2
Overview and ordering data
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-10 Festo AG & Co.
Soft-start valves/branching modules/membrane air dryers HEL/FRM/LDM-series service units
Size Connection
M1 G�
Soft-start valve
HEL
with pneumatic actuation
Branching module
FRM
Membrane air dryer
LD
M2 G� Input pressure range 2 ... 16 bar Input pressure max. 21 bar Input pressure up to 12 barG� For atmospheric dew point –20 °CG�
M3 G�
G�
G�
183 015 HEL-M2-G�-16000
183 016 HEL-M2-G�-16000
183 017 HEL-M2-G�-16000
183 018 HEL-M3-G�-16000
183 019 HEL-M3-G�-16000
183 020 HEL-M3-G�-16000
182 965 FRM-M1-G�
182 971 FRM-M2-G�
182 977 FRM-M3-G�
183 754 LD-M3-G1/2-ECO1
183 756 LD-M3-G1/2-ECO2
183 758 LD-M3-G1/2-ECO3
183 760 LD-M3-G1/2-ECO4
For atmospheric dew point
–20 °C (–40 °C)
183 753 LD-M3-G1/2-STD1
183 755 LD-M3-G1/2-STD2
183 757 LD-M3-G1/2-STD3
183 759 LD-M3-G1/2-STD4
Technical data/dimensions
� starting on Vol.3 / 10.2-52
Technical data/dimensions
� starting on Vol.3 / 10.2-56
Technical data/dimensions
� starting on Vol.3 / 10.2-58
Mounting accessories Mounting brackets, connectors, piping connectors� starting on Vol.3 / 10.2-72
Standard plug socket Pressure switches, double nipples,
34 583 MSSD-C
, pp ,
plug sockets� starting
Plug socket with cable
p g g
on Vol.3 / 10.2-80
30 931 KMC-1-24-2.5-LED
30 933 KMC-1-24-5-LED
30 932 KMC-1-220/230-2,5
30 934 KMC-1-220/230-5
/
10.2
Overview and ordering data
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-11Festo AG & Co.
Service unit combinations LFRM-series service units
LFR-M-...-KA LFR-M-...-KB LFR-M-...-KC Size ConnectionSize Connection
Consisting of:
– Filter regulator
– Branching module
– Mounting brackets
Consisting of:
– Manual on-off valve
– Filter regulator
– Branching module
– Mounting brackets
Consisting of:
– Manual on-off valve
– Filter regulator
– Mounting brackets
M1 G�
M2 G�
G�
Pressure regulation range up to 10 bar M3 G�
Grade of filtration 40 µm
With pressure gauge
Manual condensate drain
184 367 LFR-M1-G�-KA00
184 377 LFR-M2-G�-KA00
184 391 LFR-M2-G�-KA00
184 405 LFR-M3-G�-KA00
184 369 LFR-M1-G�-KB00
184 379 LFR-M2-G�-KB00
184 393 LFR-M2-G�-KB00
184 407 LFR-M3-G�-KB00
184 371 LFR-M1-G�-KC00
184 381 LFR-M2-G�-KC00
184 395 LFR-M2-G�-KC00
184 409 LFR-M3-G�-KC00
Automatic condensate drain
184 368 LFR-M1-G�-KA01
184 378 LFR-M2-G�-KA01
184 392 LFR-M2-G�-KA01
184 406 LFR-M3-G�-KA01
184 370 LFR-M1-G�-KB01
184 380 LFR-M2-G�-KB01
184 394 LFR-M2-G�-KB01
184 408 LFR-M3-G�-KB01
184 372 LFR-M1-G�-KC01
184 382 LFR-M2-G�-KC01
184 396 LFR-M2-G�-KC01
184 410 LFR-M3-G�-KC01
Technical data/dimensions� starting on Vol.3 / 10.2-61
Pressure gauge� Vol.3 / 10.2-74 Mounting accessories
Pressure sensors, plug sockets� starting on Vol.3 / 10.2-80
Mounting brackets, connectors, piping connectors, adjustment locks, mounting nuts and filter cartridges
� starting on Vol.3 / 10.2-72
– Available with manual conden-
sate drain or integrated, auto-
matic condensate drain
– For unlubricated compressed air
supply
– Three connections are available
– Available with manual conden-
sate drain or integrated, auto-
matic condensate drain
– For unlubricated compressed air
supply
– Three connections are available
– The supply pressure can be
switched on or off
– The unit is vented when switched
off
– Available with manual conden-
sate drain or integrated, auto-
matic condensate drain
– For unlubricated compressed air
supply
– The supply pressure can be
switched on or off
– The unit is vented when switched
off
10.2
Overview and ordering data
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-12 Festo AG & Co.
Service unit combinations LFRM-series service units
Size Connection LFR-M-...-KD LFR-M-...-KE LFR-M-...-KFSize Connection
M1 G�
M2 G�
G�
M3 G�
Consisting of:
– Filter regulator
– Soft-start valve with solenoid coil
24 V DC, without plug socket
– Mounting brackets
Consisting of:
– Filter regulator
– Branching module with pressure
switch, without plug socket
– Mounting brackets
Consisting of:
– Manual on-off valve
– Filter regulator
– Branching module with pressure
switch, without plug socket
– Mounting brackets
Pressure regulation range up to 10 bar
Grade of filtration 40 µm
With pressure gauge
Manual condensate drain
184 383 LFR-M2-G�-KD00
184 397 LFR-M2-G�-KD00
184 411 LFR-M3-G�-KD00
184 373 LFR-M1-G�-KE00
184 385 LFR-M2-G�-KE00
184 399 LFR-M2-G�-KE00
184 413 LFR-M3-G�-KE00
184 375 LFR-M1-G�-KF00
184 387 LFR-M2-G�-KF00
184 401 LFR-M2-G�-KF00
184 415 LFR-M3-G�-KF00
Automatic condensate drain
184 384 LFR-M2-G�-KD01
184 398 LFR-M2-G�-KD01
184 412 LFR-M3-G�-KD01
184 374 LFR-M1-G�-KE01
184 386 LFR-M2-G�-KE01
184 400 LFR-M2-G�-KE01
184 414 LFR-M3-G�-KE01
184 376 LFR-M1-G�-KF01
184 388 LFR-M2-G�-KF01
184 402 LFR-M2-G�-KF01
184 416 LFR-M3-G�-KF01
Technical data/dimensions� starting on Vol.3 / 10.2-61
Mounting accessories Pressure gauge� Vol.3 / 10.2-74
Pressure sensors, plug sockets� starting on Vol.3 / 10.2-80
Mounting brackets, connectors, piping connectors, adjustment locks, mounting nuts and filter cartridges
� starting on Vol.3 / 10.2-72
– Available with manual conden-
sate drain or integrated, auto-
matic condensate drain
– For unlubricated compressed air
supply
– Gradual pressure build-up after
switching on prevents sudden
and uncontrolled actuator move-
ments
– Quick exhausting ensures that
pressure is rapidly reduced when
switching off
– Solenoid coil 24 V DC
– Available with manual conden-
sate drain or integrated, auto-
matic condensate drain
– For unlubricated compressed air
supply
– Two connections are available
– Electrical pressure monitoring
with adjustable switching
pressure
– Available with manual conden-
sate drain or integrated, auto-
matic condensate drain
– For unlubricated compressed air
supply
– The supply pressure can be
switched on or off
– Two connections are available
– Electrical pressure monitoring
with adjustable switching pres-
sure
– The unit is vented when switched
off
10.2
Overview and ordering data
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-13Festo AG & Co.
Service unit combinations LFRM-series service units
LFR-M-...-KG Size ConnectionSize Connection
Consisting of:
– Manual on-off valve
– Filter regulator
– On-off valve with solenoid coil 24 V DC, without plug socket
– Soft-start valve
– Branching module with pressure switch, without plug socket
– Mounting brackets
M1 G�
M2 G�
G�
M3 G�
Pressure regulation range up to 10 bar
Grade of filtration 40 µm
With pressure gauge
Manual condensate drain
184 389 LFR-M2-G�-KG00
184 403 LFR-M2-G�-KG00
184 417 LFR-M3-G�-KG00
Automatic condensate drain
184 390 LFR-M2-G�-KG01
184 404 LFR-M2-G�-KG01
184 418 LFR-M3-G�-KG01
Technical data/dimensions� starting on Vol.3 / 10.2-61
Pressure gauge� Vol.3 / 10.2-74 Mounting accessories
Pressure sensors, plug sockets� starting on Vol.3 / 10.2-80
Mounting brackets, connectors, adjustment locks, mounting nuts and filter
cartridges� starting on Vol.3 / 10.2-72
– Available with manual condensate
drain or integrated, automatic con-
densate drain
– For unlubricated compressed air
supply
– The supply pressure can be
switched on or off
– Two connections are available
– Gradual pressure build-up after
switching on prevents sudden and
uncontrolled movement of the
downstream pneumatic compo-
nents
– Quick exhausting ensures that
pressure is rapidly reduced when
the soft-start valve is switched off
– Electrical pressure monitoring with
adjustable switching pressure
– Solenoid coil 24 V DC
10.2
Overview and ordering data
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-14 Festo AG & Co.
Service unit combinations FRCM-series service units
Size Connection FRC-M-...-KA FRC-M-...-KB FRC-M-...-KCSize Connection
M1 G�
M2 G�
G�
M3 G�
Consisting of:
– Filter regulator
– Branching module
– Lubricator
– Mounting brackets
Consisting of:
– Filter regulator
– Branching module with pressure
switch, without plug socket
– Lubricator
– Mounting brackets
Consisting of:
– Manual on-off valve
– Filter regulator
– Branching module with pressure
switch, without plug socket
– Lubricator
– Mounting brackets
Pressure regulation range up to 10 bar
Grade of filtration 40 µm
With pressure gauge
Manual condensate drain
184 419 FRC-M1-G�-KA00
184 425 FRC-M2-G�-KA00
184 435 FRC-M2-G�-KA00
184 445 FRC-M3-G�-KA00
184 421 FRC-M1-G�-KB00
184 427 FRC-M2-G�-KB00
184 437 FRC-M2-G�-KB00
184 447 FRC-M3-G�-KB00
184 423 FRC-M1-G�-KC00
184 429 FRC-M2-G�-KC00
184 439 FRC-M2-G�-KC00
184 449 FRC-M3-G�-KC00
Automatic condensate drain
184 420 FRC-M1-G�-KA01
184 426 FRC-M2-G�-KA01
184 436 FRC-M2-G�-KA01
184 446 FRC-M3-G�-KA01
184 422 FRC-M1-G�-KB01
184 428 FRC-M2-G�-KB01
184 438 FRC-M2-G�-KB01
184 448 FRC-M3-G�-KB01
184 424 FRC-M1-G�-KC01
184 430 FRC-M2-G�-KC01
184 440 FRC-M2-G�-KC01
184 450 FRC-M3-G�-KC01
Technical data/dimensions� starting on Vol.3 / 10.2-61
Mounting accessories Pressure gauge� Vol.3 / 10.2-74
Pressure sensors, plug sockets� starting on Vol.3 / 10.2-80
Mounting brackets, connectors, adjustment locks, mounting nuts, filter cartridges and lubricator protective covers
� starting on Vol.3 / 10.2-72
– Available with manual condensate
drain or integrated, automatic
condensate drain
– For lubricated and unlubricated
compressed air supply
– Two connections are available for
unlubricated compressed air
supply
– One connection is available for
lubricated compressed air
– Available with manual condensate
drain or integrated, automatic
condensate drain
– For lubricated and unlubricated
compressed air supply
– One connection each available for
unlubricated and lubricated
compressed air
– Electrical pressure monitoring
with adjustable switching pres-
sure
– Available with manual condensate
drain or integrated, automatic
condensate drain
– For lubricated and unlubricated
compressed air supply
– One connection each available for
unlubricated and lubricated
compressed air
– The supply pressure can be
switched on or off
– Electrical pressure monitoring
with adjustable switching pres-
sure
– The unit is vented when switched
off
10.2
Overview and ordering data
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-15Festo AG & Co.
Service unit combinations FRCM-series service units
FRC-M-...-KE FRC-M-...-KF Size ConnectionSize Connection
Consisting of:
– Filter regulator
– Lubricator
– Soft-start valve with solenoid coil
24 V DC, without plug socket
– Mounting brackets
Consisting of:
– Manual on-off valve
– Filter regulator
– Lubricator
– Soft-start valve with solenoid coil
24 V DC, without plug socket
– Branching module with pressure
switch, without plug socket
– Mounting brackets
M1 G�
M2 G�
G�
M3 G�
Pressure regulation range up to 10 bar
Grade of filtration 40 µm
With pressure gauge
Manual condensate drain
184 431 FRC-M2-G�-KE00
184 441 FRC-M2-G�-KE00
184 451 FRC-M3-G�-KE00
184 433 FRC-M2-G�-KF00
184 443 FRC-M2-G�-KF00
184 453 FRC-M3-G�-KF00
Automatic condensate drain
184 432 FRC-M2-G�-KE01
184 442 FRC-M2-G�-KE01
184 452 FRC-M3-G�-KE01
184 434 FRC-M2-G�-KF01
184 444 FRC-M2-G�-KF01
184 454 FRC-M3-G�-KF01
Technical data/dimensions� starting on Vol.3 / 10.2-61
Pressure gauge� Vol.3 / 10.2-74 Mounting accessories
Pressure sensors, plug sockets� starting on Vol.3 / 10.2-80
Mounting brackets, connectors, adjustment locks, mounting nuts, filter
cartridges and lubricator protective covers� starting on Vol.3 / 10.2-72
– Available with manual condensate
drain or integrated, automatic
condensate drain
– For lubricated compressed air
supply
– Gradual pressure build-up after
switching on prevents sudden and
uncontrolled movement of the
downstream pneumatic compo-
nents
– Quick exhausting ensures that
pressure is rapidly reduced when
switching off
– Solenoid coil 24 V DC
– Available with manual condensate
drain or integrated, automatic con-
densate drain
– For lubricated compressed air supply
– Two connections are available for
lubricated compressed air
– The supply pressure can be switched
on or off
– Gradual pressure build-up after
switching on prevents sudden and
uncontrolled actuator movements
– Quick exhausting ensures that
pressure is rapidly reduced when the
soft-start valve is switched off
– Electrical pressure monitoring with
adjustable switching pressure
– Solenoid coil 24 V DC
10.2
Technical data
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-16 Festo AG & Co.
Pressure regulators LRM-series service units
G� ... G� Pressure regulator
LR-M-...
– Good control characteristics with
low hysteresis and primary pres-
sure compensation
– Available with or without secondary
venting
– High flow rate with minimal pres-
sure drop
– Four pressure ranges available
– Settings secured via detent on
knob and push-in adjustment lockThe pressure regulator maintains a
constant operating pressure (second-
ary side), regardless of the pressure
variations in the system (primary
side) and the air consumption.
With the secondary venting, the oper-
ating pressure can also be reduced
without consuming devices.
knob and push-in adjustment lock
– Also suitable for installation into
control panels
– Two pressure gauge connections for
different fitting options
– Directly controlled diaphragm
regulator valve
– Optional with reverse flow for im-
proved venting from output 2 to
input 1
Technical data for pressure regulator
Size M1 M2 M3
Connection G� G� G� G� G� G� G� G�
Type of mounting In-line installation, mounting bracket or installation into control panel;
Combination: flanged
Mounting position Any
Standard nominal flow
rate*
qnN [l/min]
LR-M-...-10G 760 2200 3400 5050 4500 5200 5400 7500
LR-M-...-07G 1000 2200 4000 4700 4600 6900 8200 8400
Input pressure range Max. 21 bar
Pressure regulation range Max. 7 bar, 10 bar
Temperature range –10 ... +80°C
Materials Housing: die-cast Zn; regulator knob: acetal; protective cover: ABS; seals: NBR
Weight 0.316 kg 0.747 kg 1.013 kg
* Measured at p1 = 10 bar, p2 = 6 bar and �p = 1 bar
10.2
Technical data
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-17Festo AG & Co.
Pressure regulators LRM-series service units
LR-M1-G�-07-... LR-M1-G�-07-... Characteristic curves for flow rate*
Standard flow rate qn [l/min]
Outputpressurep2
[bar]
Standard flow rate qn [l/min]
Outputpressurep2
[bar]
LR-M2-G�-07-... LR-M2-G�-07-...
Standard flow rate qn [l/min]
Outputpressurep2
[bar]
Standard flow rate qn [l/min]
Outputpressurep2
[bar]
LR-M3-G�-07-...
Standard flow rate qn [l/min]
Outputpressurep2
[bar]
* p1 = 10 bar
10.2
Type code
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-18 Festo AG & Co.
Pressure regulators LRM-series service units
Function
LR = Pressure
regulator Series
M = Modular
Size
1 = Size 1
2 = Size 2
3 = Size 3
Thread type
G = BSP
Connection size
� = G�
� = G�
� = G�
� = G�
� = G�
Options
G = With pressure gauge
I = Return flow
K = Without secondary venting
Pressure regulation range
04 = 0 ... 4 bar
07 = 0 ... 7 bar
10 = 0 ... 10 bar
16 = 0 ... 16 bar*
* Except size 1
L R M— ——
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
10.2
Dimensions
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-19Festo AG & Co.
Pressure regulators LRM-series service units
1 Mounting bracket HWR (not
included in scope of delivery)
2 Second pressure gauge
connection G�
� Flow direction
LR-M1-...
Type B1 B2 B3 B4 B5 B6 B7 B8 B9 D1 D2
�
D5 L1 L2 L6 L7 L8
max.
L9 L10
LR-M1-... 40 67 21.3 40 2 44 68 8 22 G� 23 7 100 66 44 52.5 3.5 2 2
G�
1 Mounting bracket HWR (not
included in scope of delivery)
2 Second pressure gauge
connection G�
� Flow direction
LR-M2/M3-...
Type B1 B2 B3 B4 B5 B6 B7 B8 B9 D1
�
D2 D5 L1 L2 L6 L7 L8
max.
L9
LR-M2-... 60 94 30 40 2.7 42 70 8 32 G� 41 7 137 93 57 66.5 5 3
G�
G�
LR-M3-... 73 108 36.5 49 2.7 47.6 76 8 38.5 G� 41 7 149 104 57 66.5 5 4
G�
G�
10.2
Technical data
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-20 Festo AG & Co.
Pressure regulators LRBM-series service units
G� ... G� Pressure regulator
LRB-M-...
with through pressure supply for
manifold assembly
The pressure regulator is suitable for
manifold assemblies with through air
supply on both sides, for configuring
of a regulator manifold with separate,
independent pressure ranges. There
i t t b th idis a pressure output on both sides.
– Good control characteristics with
low hysteresis and primary pres-
sure compensation
– Manifold assembly with through air
supplysupply
– For the configuring of a regulator
LRB-... Manifold
For the configuring of a regulator
manifold with separate, indepen-p , p
dent pressure ranges
– Four pressure ranges available
– Settings secured via detent on
k b d h i dj t t l kknob and push-in adjustment lock
– Directly controlled diaphragm
regulator valve
Technical data for pressure regulator
Size M1 M2
Connection G� G�
Type of mounting In-line installation, mounting bracket or installation into control panel;
Combination: flanged
Mounting position Any
Standard nominal flow qnN [l/min]
rate* LRB-M1-G�-10 620 –
LRB-M1-G�-07 740 –
LRB-M2-G�-10 – 1440
LRB-M2-G�-07 – 1450
Input pressure range Max. 21 bar
Pressure regulation range Max. 7 bar, 10 bar
Temperature range –10 ... +80°C
Materials Housing: die-cast Zn; regulator knob: acetal; protective cover: ABS; seals: nitrile
Weight 0.244 kg 0.575 kg
* Measured at p1 = 10 bar, p2 = 6 bar and �p = 1 bar
10.2
Technical data
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-21Festo AG & Co.
Pressure regulators LRBM-series service units
LRB-M1-G�-10-... LRB-M1-G�-07-... Characteristic curves for flow rate*
Standard flow rate qn [l/min]
Outputpressurep2
[bar]
Standard flow rate qn [l/min]
Outputpressurep2
[bar]
LRB-M2-G�-10-... LRB-M2-G�-07-...
Standard flow rate qn [l/min]
Outputpressurep2
[bar]
Standard flow rate qn [l/min]
Outputpressurep2
[bar]
* p1 = 10 bar
10.2
Type code
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-22 Festo AG & Co.
Pressure regulators LRBM-series service units
Function
LRB = Pressure regulator
for manifold assembly Series
M = Modular
Size
1 = Size 1
2 = Size 2
Thread type
G = BSP
Connection size
� = G�
� = G�
Options
K = Without secondary venting
Pressure regulation range
04 = 0 ... 4 bar
07 = 0 ... 7 bar
10 = 0 ... 10 bar
16 = 0 ... 16 bar*
* Except size 1
L R B M— —
1 2 3 4 5 6 7
—
8 9 10 11 12 13 14 15
10.2
Dimensions
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-23Festo AG & Co.
Pressure regulators LRBM-series service units
LRB-M1-...
3 Second connection for regulated
output pressure
4 Mounting bracket LVH (not
included in scope of delivery)
� Flow direction
Type B1 B2 B3 B4 B8 B9 D1 D2
�
D3 D5 L1 L2 L6 L7 L8
max.
L9 L13
LRB-M1-... 40 42.6 21.3 40 2 22 G� – G� 5.5 100 66 45 35 3.5 2 100
LRB-M2-...
3 Second connection for regulated
output pressure
5 Mounting bracket LVH (not
included in scope of delivery)
� Flow direction
Type B1 B2 B3 B4 B5 B6 B8 B9 D1 D2
�
D3 D5 L1 L2 L6 L7 L8
max.
L9
LRB-M2-... 60 60 30 40 2 64.5 3 32 G� – G� 7 137 93 41.5 49 5 3
10.2
Technical data
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-24 Festo AG & Co.
Filters LFM-series service units
G� ... G� Filter
LF-M-...
The sintered filter with water separ-
ator removes dirt, pipe sinter, rust
and condensate from the compressed
air.
The filter cartridges are exchangeable.
– Good particle and condensate
separation
– High flow rate with minimal
pressure drop
– Option of 40 or 5 µm filter
cartridge
– Available with manual condensate
drain or integrated, automatic
condensate drain
Technical data for filter
Size M1 M2 M3
Connection G� G� G� G� G� G� G� G�
Type of mounting In-line installation, mounting bracket or installation into control panel;
Combination: flanged
Mounting position Vertical ±5°
Standard nominal flow
rate*
qnN [l/min]
LF-M-...(ER/ES-40 µm) 1100 1800 2700 4400 5900 4700 6100 7600
LF-M-...(CR/CS-5 µm) 1100 1700 2600 4400 5800 4600 6000 7500
Input pressure range Max. 12 bar
Grade of filtration 40 µm, 5 µm
Condensate volume 10 ml 53 ml 65 ml
Temperature range –10 ... +60°C (M1: –10 ... +40°C)
Materials Housing: die-cast Zn; protective cover: ABS; plastic bowl: polyamide; metal bowl: die-cast Zn; seals: NBR
Weight 0.20 kg 0.482 kg 0.842 kg
* Measured at p1 = 6 bar and �p = 1 bar
10.2
Technical data
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-25Festo AG & Co.
Filters LFM-series service units
LF-M1-G�-C-... LF-M1-G�-C-... Characteristic curves for flow rate
Standard flow rate qn [l/min]
Differentialpressure[bar]
Standard flow rate qn [l/min]
Differentialpressure[bar]
LF-M2-G�-C-... LF-M2-G�-C-...
Standard flow rate qn [l/min]
Differentialpressure[bar]
Standard flow rate qn [l/min]
Differentialpressure[bar]
LF-M3-G�-C-...
Standard flow rate qn [l/min]
Differentialpressure[bar]
10.2
Type code
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-26 Festo AG & Co.
Filters LFM-series service units
Function
LF = Compressed air
filter Series
M = Modular
Size
1 = Size 1
2 = Size 2
3 = Size 3
Thread type
G = BSP
Connection size
� = G�
� = G�
� = G�
� = G�
� = G�
Bowls
R = Plastic/manual drain
S = Plastic/automatic drain
T = Metal/manual drain*
with sight glass**
U = Metal/automatic drain*
with sight glass**
Grade of filtration
C = 5 µm
E = 40 µm
* Input pressure max. 17 bar
** Metal bowl M1 without sight glass
L F M— ——
1 2 3 4 5 6 7 8 9 10 11 12 13
10.2
Dimensions
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-27Festo AG & Co.
Filters LFM-series service units
1 Mounting bracket HWF-M1 (not
included in scope of delivery)
3 Manual condensate drain,
barbed fitting for plastic tubing
PUN/PAN-6x1
4 Automatic condensate drain,
barbed fitting for plastic tubing
PUN/PAN 8x1.25
5 Installation dimensions
� Flow direction
LF-M1-...
Type B1 B2 B3 B4 B5 B6 B7 B8 D1 D3
�
D4
�
D5 L1 L2 L3
ap-
prox.
L4
min.
L5
ap-
prox.
L6 L7
LF-M1-... 40 42.6 21.3 40 2 44 68 10 G� 4 7.2 6.5 102 18.1 15 33 10 35 43.5
G�
2 Mounting bracket HW (not
included in scope of delivery)
4 Manual condensate drain,
barbed fitting for plastic tubing
PUN/PAN 8x1.25
5 Installation dimensions
6 Pipe connector LVR (not included
in scope of delivery)
7 Automatic condensate drain,
thread for connector QSF-�-6-B
with plug connection for plastic
tubing PUN/PAN 6x1
� Flow direction
LF-M2/M3-...
Type B1 B2 B3 B4 B5 B6 B7 B8 B9 D1 D3
�
D4 D5 L1 L2 L3
ap-
prox.
L4
min.
L5
ap-
prox.
L6 L7
LF-M2-... 60 60 30 40 2 69 88 3 128 G� 5.2 G� 7 158 26 29 59 19 41.5 49
G�
G�
LF-M3-... 73 73 36.5 40 2 82 101 3 141 G� 5.2 G� 7 183 26 29 85 19 41.5 493
G�
G�
10.2
Technical data
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-28 Festo AG & Co.
Fine, micro and active carbon filters LFMM-series service units
G� ... G� LFM-M-...-B...
Fine filter 1 µm
with plastic bowl and bowl guard
Many branches of industry frequently
require fine or micro-filtered air:
chemicals, pharmaceuticals, process
technology, food industry, etc. Fine
and micro filters clean compressed
air almost completely of any remain-air almost completely of any remain-
ing minute water and oil droplets, as
well as any dirt particles.
– High-performance filter for techni-
cally oil-free compressed air
LFM-M-...-A...
Micro filter 0.01 µm
with plastic bowl and bowl guard
– Optional 1 µm or 0.01 µm filter
cartridges
– Active carbon filter cartridges pro-
vide odour and oil-free air to food
industry standard
– Air quality to ISO 8573-1, up toLFM-M-...-X...
Active carbon filter
Residual oil content: 0.003 mg/m3,
with plastic bowl and bowl guard
– Air quality to ISO 8573-1, up to
class 1.7.1
– Available with manual condensate
drain or integrated, automatic
condensate drain
– Differential pressure display
(M2/M3 only)
Technical data for fine, micro and active carbon filters
Size M1 M2 M3
Connection G� G� G� G� G� G� G�
Type of mounting In-line installation, mounting bracket;
Combination: flanged
Mounting position Vertical ±5°
Standard nominal flow
rate*
qnN [l/min]
LFM-M-...-BR/BS 140 480 630 700 850 1000 1100
LFM-M-...-AR/AS 80 400 430 480 450 580 600
LFM-M-...-XR 210 680 950 1200 1200 1520 1800
Input pressure range Max. 12 bar
Grade of filtration 1 µm, 0.01 µm
Filter efficiency 99.9999%
Condensate volume 10 ml 53 ml 65 ml
Temperature range –10 ... +60°C (M1: –10 ... +40°C)
Materials Housing: die-cast Zn; protective cover: ABS; plastic bowl: nylon; metal bowl: die-cast Zn; seals: NBR
Weight 0.244 kg 0.600 kg 0.908 kg
* Measured at p1 = 6 bar and �p = 0.07 bar
10.2
Technical data
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-29Festo AG & Co.
Fine, micro and active carbon filters LFMM-series service units
LFM-M1-G�-B-... LFM-M1-G�-A-... Characteristic curves for flow rate
Standard flow rate qn [l/min]
Differentialpressure[bar]
Standard flow rate qn [l/min]
Differentialpressure[bar]
LFM-M1-G�-X-... LFM-M2-G�-B-...
Standard flow rate qn [l/min]
Differentialpressure[bar]
Standard flow rate qn [l/min]
Differentialpressure[bar]
LFM-M2-G�-A-... LFM-M3-G�-X-...
Standard flow rate qn [l/min]
Differentialpressure[bar]
Standard flow rate qn [l/min]
Differentialpressure[bar]
10.2
Type code
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-30 Festo AG & Co.
Fine, micro and active carbon filters LFMM-series service units
Function
LFM = Fine and
micro filters Series
M = Modular
Size
1 = Size 1
2 = Size 2
3 = Size 3
Thread type
G = BSP
Connection size
� = G�
� = G�
� = G�
� = G�
Bowls
R = Plastic/manual drain
S = Plastic/automatic drain
T = Metal/manual drain**
with sight glass***
U = Metal/automatic drain**
with sight glass***
Grade of filtration
A = 0.01µm
B = 1 µm
X = AC*
* Only in connection with bowl types R and T
** Primary pressure max. 17 bar
*** Metal bowl M1 without sight glass
L F M M— —
1 2 3 4 5 6 7
—
8 9 10 11 12 13 14
10.2
Dimensions
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-31Festo AG & Co.
Fine, micro and active carbon filters LFMM-series service units
1 Mounting bracket HWF (not
included in scope of delivery)
3 Manual condensate drain,
barbed fitting for plastic tubing
PUN/PAN-6 x 1
4 Automatic condensate drain,
barbed fitting for plastic tubing
PUN/PAN 8x1.25
5 Installation dimensions
� Flow direction
LFM-M1-...
Type B1 B2 B3 B4 B5 B6 B7 B8 B9 D1
�
D3
�
D4 D5 L1 L2 L3
ap-
prox.
L4
min.
L5
ap-
prox.
L6 L7
LFM-M1-... 40 42.6 21.3 40 2 44 68 10 — G� 4 7.2 6.5 102 18 15 33 10 35 43.5
G�
2 Mounting bracket HW (not
included in scope of delivery)
4 Manual condensate drain,
barbed fitting for plastic tubing
PUN/PAN 8x1.25
5 Installation dimensions
6 Pipe connector LVR (not included
in scope of delivery)
7 Automatic condensate drain,
thread for connector QSF-�-6-B,
with plug connection for plastic
tubing PUN/PAN 6x1
� Flow direction
LFM-M2/M3-...
Type B1 B2 B3 B4 B5 B6 B7 B8 B9 D1 D3
�
D4 D5 L1 L2 L3
ap-
prox.
L4
min.
L5
ap-
prox.
L6 L7
LFM-M2-... 60 60 30 40 2 69 88 3 128 G� 5.2 G� 7 179 48 29 59 19 41.5 49
G�
G�
LFM-M3-... 73 73 36.5 40 2 82 101 3 141 G� 5.2 G� 7 205 48 29 85 19 41.5 493
G�
G�
10.2
Technical data
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-32 Festo AG & Co.
Filter regulators LFRM-series service units
G� ... G� LFR-M-... – Good control characteristics with
low hysteresis and primary pres-
sure compensation
– Available with or without secondary
venting
– Good particle and condensate sep-
aration
– High flow rate and highly efficient in
removing contaminants
– Settings secured via detent on
knob and push-in adjustment lock
– Four pressure ranges: 4, 7, 10 and
16 bar
This device combines a filter and
pressure regulator into one unit. The
sintered filter with water separator
removes dirt, pipe sinter, rust and
condensate from the compressed air.
(16 bar not available in size 1)
– Two pressure gauge connections for
different fitting options
– High flow rate with minimal pres-
sure drop
– Optional 40 µm or 5 µm filter
cartridges
– Available with manual condensate
drain or integrated, automatic
condensate drain
Technical data for filter regulator
Size M1 M2 M3
Connection G� G� G� G� G� G� G� G�
Type of mounting In-line installation, mounting bracket or installation into control panel;
Combination: flanged
Mounting position Vertical ±5°
Standard nominal flow
rate*
qnN [l/min]
LFR-M-...(E10RG/E10SG) 450 2000 3100 5200 4500 5100 4400 3000
LFR-M-...(E07RG/E07SG) 1100 1900 2700 5200 5300 6800 7800 9200
Input pressure range Max. 12 bar (1 ... 17 bar with metal bowl)
Pressure regulation range Max. 10 bar
Grade of filtration 40 µm, 5 µm
Condensate volume 10 ml 53 ml 65 ml
Temperature range –10 ... +60 °C (M1: –10 ... +40 °C)
Materials Housing: die-cast Zn; regulator knob: acetal; plastic bowl: polycarbonate; metal bowl: die-cast Zn; seals:
NBR
Weight 0.37 kg 1 kg 1.5 kg
* Measured at p1 = 10 bar, p2 = 6 bar and �p = 1 bar
10.2
Technical data
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-33Festo AG & Co.
Filter regulators LFRM-series service units
LFR-M1-G�-CO7 LFR-M1-G�-CO7 Characteristic curves for flow rate*
Standard flow rate qn [l/min]
Outputpressurep2
[bar]
Standard flow rate qn [l/min]
Outputpressurep2
[bar]
LFR-M2-G�-CO7 LFR-M2-G�-CO7
Standard flow rate qn [l/min]
Outputpressurep2
[bar]
Standard flow rate qn [l/min]
Outputpressurep2
[bar]
LFR-M3-G�-CO7
Standard flow rate qn [l/min]
Outputpressurep2
[bar]
* p1 = 10 bar
10.2
Type code
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-34 Festo AG & Co.
Filter regulators LFRM-series service units
Function
LFR = Compressed
air filter regulator Series
M = Modular
Size
1 = Size 1
2 = Size 2
3 = Size 3
Thread type
G = BSP
Connection size
� = G�
� = G�
� = G�
� = G�
� = G�
Options
G = With pressure gauge
K = Without secondary venting
Bowls
R = Plastic/
manual drain
S = Plastic/
automatic drain
T = Metal/
manual drain**
with sight glass***
U = Metal/
automatic drain**
with sight glass***
Pressure regulation range
04 = 0 ... 4 bar
07 = 0 ... 7 bar
10 = 0 ... 10 bar
16 = 0 ... 16 bar*
Grade of filtration
C = 5 µm
E = 40 µm
* Except size 1 and designs with plastic bowls
** Primary pressure max. 17 bar
*** Metal bowl M1 without sight glass
L F R M— —
1 2 3 4 5 6 7
—
8 9 10 11 12 13 14 15 16 17 18
10.2
Dimensions
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-35Festo AG & Co.
Filter regulators LFRM-series service units
1 Angle bracket HWR (not included
in scope of delivery)
2 Second pressure gauge
connection
3 Manual condensate drain,
barbed fitting for plastic tubing
PUN/PAN-6 x 1
4 Automatic condensate drain,
barbed fitting for plastic tubing
PUN/PAN-8 x 1.5
5 Installation dimensions
� Flow direction
LFR-M1-...
Type B1 B2 B3 B4 B5 B6 B7 B8 B9 D1 D2
�
D3
�
D4
�
D5 L1 L2 L3
ap-
prox.
L4
min.
L5
ap-
prox.
L6 L7 L8
max.
L9 L10
LFR-M1-... 40 67 21.3 40 2 44 68 8 22 G� 23 4 7.2 7 150 66 15 33 10 44 52.2 3.5 2 2
G�
1 Angle bracket HWR (not included
in scope of delivery)
2 Second pressure gauge
connection
4 Manual condensate drain,
barbed fitting for plastic tubing
PUN/PAN-8 x 1.25
5 Installation dimensions
6 Automatic condensate drain,
thread for connector QSF-�-6-B
with plug connection for plastic
tubing PUN/PAN 6 x 1
� Flow direction
LFR-M2/M3-...
Type B1 B2 B3 B4 B5 B6 B7 B8 B9 D1 D2
�
D3
�
D4 D5 L1 L2 L3
ap-
prox.
L4
min.
L5
ap-
prox.
L6 L7 L8
max.
L9 L10
LFR-M2-... 60 94 30 40 2.7 42 70 8 32 G� 41 5.2 G� 7 224 93 29 59 19 57 66.5 5 3 –
G�
G�
LFR-M3-... 73 108 36.5 49 2.7 47.6 76 8 38.5 G� 41 5.2 G� 7 260 104 29 85 19 57 66.5 5 4 –
G�
G�
10.2
Technical data
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-36 Festo AG & Co.
Lubricators LOEM-series service units
G� ... G� The proportional lubricator adds a
precisely metered quantity of oil to
The following oils are recommended
for Festo units:
the compressed air.
The pressure drop that occurs when
air flows through a Venturi nozzle is
used to convey oil from the container
to the drip cap. From there, the oil
Suitable oils:
Festo special oil
ARAL Vitam GF 32
BP Energol HLP 32to the drip cap. From there, the oil
drips into the air duct directly behind
the proportional valve, where it is ato-
BP Energol HLP 32
Esso Nuto H 32
Mobil DTE 24the proportional valve, where it is ato
mised.
The oil mist ratio is proportional to
h h d
Mobil DTE 24
Shell Tellus Oil DO 32
the flow rate of the compressed air.
– Proportional lubricator with preci
Viscosity range
32 mm2/s
(= cSt) at 40 °C– Proportional lubricator with preci-
sion oil metering
– Reduces wear on highly stressed
(= cSt) at 40 °C
ISO class VG 32 to ISO 3448
– Reduces wear on highly stressed
drive units
– High flow rate
Festo special oil in 1 litre containers
Order code 152 811 OFSW-32g
– Oil top-up even during operation
Technical data for lubricator
Size M1 M2 M3
Connection G� G� G� G� G� G� G� G�
Type of mounting In-line installation, mounting bracket;
Combination: flanged
Mounting position Vertical ±5°
Standard nominal flow
rate*
qnN [l/min]
LOE-M-... 1100 2200 2800 5300 7500 5200 6700 6800
Input pressure range Max. 12 bar
Start of lubrication func-
tion
From 20 l/min From 20 l/min From 25 l/min
Oil filling volume 22.5 ml 99 ml 189 ml
Temperature range –10 ... +60 °C (M1: –10 ... +40 °C)
Materials Housing: die-cast Zn; protective cover: ABS; plastic bowl: nylon; metal bowl: die-cast zinc;
seals: NBR, nylon
Weight (with pressure gauge) 0.594 kg 1.663 kg 2.366 kg
* Measured at p1 = 6 bar and �p = 1 bar
10.2
Technical data
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-37Festo AG & Co.
Lubricators LOEM-series service units
LOE-M1-G�-P-... LOE-M1-G�-P-... Characteristic curves for flow rate
Standard flow rate qn [l/min]
Differentialpressure[bar]
Standard flow rate qn [l/min]
Differentialpressure[bar]
LOE-M2-G�-P-... LOE-M2-G�-P-...
Standard flow rate qn [l/min]
Differentialpressure[bar]
max. perm. qn = 7500 l/min
Standard flow rate qn [l/min]
Differentialpressure[bar]
LOE-M3-G�-P-...
max. perm. qn = 7500 l/min
Standard flow rate qn [l/min]
Differentialpressure[bar]
10.2
Type code
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-38 Festo AG & Co.
Lubricators LOEM-series service units
Function
LOE = Compressed air
lubricator Series
M = Modular
Size
1 = Size 1
2 = Size 2
3 = Size 3
Thread type
G = G thread
Connection size
� = G�
� = G�
� = G�
� = G�
� = G�
Bowls
P = Plastic/without drain
Q = Metal/without drain*
with sight glass**
* Input pressure max. 17 bar
** Metal bowl M1 without sight glass
L O E M— —
1 2 3 4 5 6 7
—
8 9 10 11 12 13
10.2
Dimensions
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-39Festo AG & Co.
Lubricators LOEM-series service units
1 Mounting bracket HWF (not
included in scope of delivery)
2 Installation dimensions
� Flow direction
Metal bowl without sight glass
LOE-M1...
Type B1 B2 B3 B4 B5 B6 B7 B8 B9 D1 D5 L1 L2 L4 L6
min.
L7 L8
LOE-M1-... 40 42.6 21.3 40 2 44 68 10 – G� 6.5 134 – 58 35 43.5 46
G�
2 Installation dimensions
3 Pipe connector LVR (not included
in scope of delivery)
4 Mounting bracket HW (not
included in scope of delivery)
� Flow direction
LOE-M2/M3-...
Type B1 B2 B3 B4 B5 B6 B7 B8 B9 D1 D5 L1 L2
min.
L4 L6 L7 L8
LOE-M2-... 60 60 30 40 2 69 88 3 128 G� 7 201 23 96 41.5 49 48
G�
G�
LOE-M3-... 73 73 36.5 40 2 82 101 3 141 G� 7 227 23 125 41.5 49 483
G�
G�
10.2
Technical data
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-40 Festo AG & Co.
Service units FRCM-series service units
G� ... G� Service unit
FRC-M-...
– Good particle and condensate
separation
– High flow rate and highly efficient
removal of contaminants
– Settings secured via detent on
knob and push-in adjustment lock
– Four pressure ranges available
– Two pressure gauge connections for
different fitting options
– Option of 40 or 5 µm filter car-
tridges
– Available with manual condensate
drain or integrated, automatic
Service units simplify provision of
filtered, lubricated, compressed air.
The filter cleans the compressed air,
the regulator controls the pressure
and compensates for fluctuations and
the lubricator doses the cleaned air
with a metered oil mist. Filter and lu-
bricator bowls can be easily removed
for cleaning purposes thanks to the
bayonet fitting.
condensate drain
– Secondary lubricator with precision
oil metering
– Oil top-up even during operation
– Filter, regulator and lubricator
functions in a single unit
– Good control characteristics with
low hysteresis and primary pres-
sure compensation
Technical data for service unit
Size M1 M2 M3
Connection G� G� G� G� G� G� G� G�
Type of mounting In-line installation, mounting bracket;
Combination: flanged
Mounting position Vertical ±5°
Standard nominal flow
rate*
qnN [l/min]
FRC-M-...(E10RG/E10SG) 440 440 1000 3500 3700 2800 3000 2800
FRC-M-...(E07RG/E07SG) 540 770 1600 4400 4200 2800 3100 2800
Input pressure range Max. 12 bar
Pressure regulation range Max. 10 bar/max. 7 bar
Oil filling volume 22.5 ml 99 ml 189 ml
Grade of filtration 40 µm, 5 µm
Condensate volume 10 ml 53 ml 65 ml
Temperature range –10 ... +60 °C (M1: –10 ... +40 °C)
Materials Housing: die-cast Zn; plastic bowl: polycarbonate; metal bowl: die-cast Zn; lubricator sight glass:
nylon; seals: NBR
Weight (with pressure gauge) 0.594 kg 1.663 kg 2.366 kg
* Measured at p1 = 10 bar, p2 = 6 bar and �p = 1 bar
10.2
Technical data
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-41Festo AG & Co.
Service units FRCM-series service units
FRC-M1-G�-C10-... FRC-M1-G�-C10-... Characteristic curves for flow rate*
Standard flow rate qn [l/min]
Outputpressurep2
[bar]
Standard flow rate qn [l/min]
Outputpressurep2
[bar]
FRC-M2-G�-C07-... FRC-M2-G�-C07-...
Standard flow rate qn [l/min]
Outputpressurep2
[bar]
Standard flow rate qn [l/min]
Outputpressurep2
[bar]
FRC-M2-G�-C07
Standard flow rate qn [l/min]
Outputpressurep2
[bar]
* p1 = 10 bar
10.2
Type code
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-42 Festo AG & Co.
Service units FRCM-series service units
Function
FRC = Compressed air
service unit Series
M = Modular
Size
1 = Size 1
2 = Size 2
3 = Size 3
Thread type
G = G thread
Connection size
� = G�
� = G�
� = G�
� = G�
� = G�
Options
G = With pressure gauge
K = Without secondary venting
Bowls
R = Plastic/
manual drain
S = Plastic/
automatic drain
T = Metal/manual drain**
with sight glass***
U = Metal/
automatic drain**
with sight glass***
Pressure regulation range
04 = 0 ... 4 bar
07 = 0 ... 7 bar
10 = 0 ... 10 bar
16 = 0 ... 16 bar*
Grade of filtration
C = 5 µm
E = 40 µm
* Except size 1 and designs with plastic bowls
** Input pressure max. 17 bar
*** Metal bowl M1 without sight glass
F R C M— —
1 2 3 4 5 6 7
—
8 9 10 11 12 13 14 15 16 17 18
10.2
Dimensions
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-43Festo AG & Co.
Service units FRCM-series service units
1 Mounting bracket LVH (not
included in scope of delivery)
2 Second pressure gauge
connection (G�)
3 Manual condensate drain,
barbed fitting for plastic tubing
PUN/PAN-6 x 1
4 Automatic condensate drain,
barbed fitting for plastic tubing
PUN/PAN 8 x 1.25
5 Installation dimensions
� Flow direction
Metal bowl without sight glass
FRC-M1-...
Type B1 B2 B3 B4 B5 B6 B7 B8 B9 D1 D2
�
D3
�
D4
�
D5 L1 L2 L3
ap-
prox.
L4
min.
L5
ap-
prox.
L6 L7 L8 L9 L10 L11 L12
min.
L13
FRC- 80 67 21.3 40 40 40 20 2 22 G� 23 4 7.2 5.5 150 66 15 33 10 45 35 46 2 2 134 58 100
M1-... G�
1 Mounting bracket LVH (not
included in scope of delivery)
2 Second pressure gauge
connection (G�)
4 Manual condensate drain,
barbed fitting for plastic tubing
PUN/PAN 8 x 1.25
5 Installation dimensions
6 Automatic condensate drain,
thread for connector QSF-�-6-B
with plug connection for plastic
tubing PUN/PAN-6 x 1
� Flow direction
FRC-M2/M3-...
Type B1 B2 B3 B4 B5 B6 B7 B8 B9 D1 D2
�
D3
�
D4 D5 L1 L2 L3
ap-
prox.
L4
min.
L5
ap-
prox.
L6 L7 L8 L9 L11 L12
min.
L14
FRC- 129 94 30 40 2 64.5 30 3 69 G� 41 5.2 G� 7 224 93 29 59 19 41.5 49 48 3 201 96 23
M2-... G�
G�
FRC- 155 108 36.5 40 2 77.5 36.5 3 82 G� 41 5.2 G� 7 260 104 29 85 19 41.5 49 48 3 227 125 23
M3-... G�
G�
10.2
Technical data
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-44 Festo AG & Co.
Manual on-off valves HEA/HEBM-series service units
G� ... G� On-off valve
manually operated
Flow direction
from left to right
HEA-M-...*
Flow direction
from right to left
HEB-M-...
– 3/2-way manual shut-off valve
– The unit is vented when switched
off
– The switching position is im-
mediately recognisable
– Commercially available padlock
can be used for security
This safety shut-off valve is used to
pressurise and vent pneumatic
systems.
The toggle lever can be held in the
locked position using a conventional
padlock.
M1: Overlap free
*HEA-M-...- is suitable for both flow
directions in size M1.
M1: Overlap free
M2: Not free of overlap
M3: Not free of overlap
HEA-... HEB-...
Air supply from left Air supply from right
Technical data for manual on-off valve
Size M1 M2 M3
Connection G� G� G� G� G� G� G� G�
Type of mounting In-line installation; combination: flanged
Mounting position Any
Standard nominal flow qnN [l/min]
rate* HEA-M-... 1600 3800 4000 8300 7700 7200 10000 9700
HEB-M-... – – 4000 8300 7700 7200 10000 9700
Input pressure range Max. 12 bar
Temperature range –10 ... +80 °C
Materials Housing: die-cast Zn; toggle lever: acetal; seals: NBR and nitrile
Weight (with pressure gauge) 0.337 kg 0.425 kg 0.500 kg
* Measured at p1 = 6 bar and �p = 1 bar
10.2
Technical data
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-45Festo AG & Co.
Manual on-off valves HEA/HEBM-series service units
HEA-M1-G� HEA-M1-G� Characteristic curves for flow rate*
Standard flow rate qn [l/min]
Differentialpressure[bar]
Standard flow rate qn [l/min]
Differentialpressure[bar]
HEA/HEB-M2-G�-... HEA/HEB-M2-G�-...
Standard flow rate qn [l/min]
Differentialpressure[bar]
Standard flow rate qn [l/min]
Differentialpressure[bar]
HEA/HEB-M3-G�
Standard flow rate qn [l/min]
Differentialpressure[bar]
* p1 = 10 bar
10.2
Type code
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-46 Festo AG & Co.
Manual on-off valves HEA/HEBM-series service units
Function
HEA = Manual
on-off valve
(Direction of flow
from left to right)
Series
M = Modular
Size
1 = Size 1
2 = Size 2
3 = Size 3
Thread type
G = G thread
Connection size
� = G�
� = G�
� = G�
� = G�
� = G�
H E A M—
1 2 3 4 5 6 7
—
8 9 10 11
Function
HEB = Manual
on-off valve
(Direction of flow
from right to left)
Series
M = Modular
Size
2 = Size 2
3 = Size 3
Thread type
G = G thread
Connection size
� = G�
� = G�
� = G�
� = G�
H E B M—
1 2 3 4 5 6 7
—
8 9 10 11
10.2
Dimensions
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-47Festo AG & Co.
Manual on-off valves HEA/HEBM-series service units
Closed Open
1 Mounting bracket HWF (not
included in scope of delivery)
2 Holes for locking with padlock
� Flow direction
HEA-M1-...
Type B1 B2 B3 B4 B5 B6 B7 B8 B9 D1 D2 D5 L1 L2 L3
ap-
prox.
L4 L5
ap-
prox.
L6 L7
HEA-M1-... 40 42.6 21.3 40 2 44 68 10 – G� 7.4 6.5 61 30.5 26 – 42 35 43.5
G�
Closed OpenHEA-... HEA/HEB-M2/M3-...
HEB-...
2 Holes for locking with padlock
3 Mounting bracket HW (not
included in scope of delivery)
4 Pipe connector LVR (not included
in scope of delivery)
� Flow direction
Type B1 B2 B3 B4 B5 B6 B7 B8 B9 D1 D2 D5 L1 L2 L3
ap-
prox.
L4 L5
ap-
prox.
L6 L7
HEA-M2-... 49 60 30 40 2 58 77 3 117 G� 8 7 58 26 49 2.5 52 41.5 49
HEB-M2-... G�
G�
HEA-M3-... 58 65 32.5 40 2 67 86 3 126 G� 8 7 58 26 50 2.5 54 41.5 493
HEB-M3-... G�
G�
10.2
Technical data
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-48 Festo AG & Co.
Soft-start valves HEM/HEMSM-series service units
G� ... G� HEM-M-... – Soft-start valve for gradual pres-
with dump function and quick
exhaust
g p
sure build-up
– Drives are moved slowly and safely
to their initial positions
– Sudden and unexpected move-
ments are avoided
– Quick exhausting ensures safety
and time saving during operation
d iThe valve can be combined with
M-series service units.
and service
– Three voltage ranges can be
selectedSoft-start valve (electrical) with sole-
noid coil, without plug socket, with
manual override, dump function and
quick exhaust, free of overlap.
selected
Soft-start valve for gradual pressure
build-up in pneumatic systems.
Pressure is built up gradually. Down-Pressure is built up gradually. Down-
stream cylinders and operating units
HEMS-M-...
without manual override
stream cylinders and operating units
are slowly moved to their initial
positions.
It can be combined with service units
as a safety on-off valve for pneumatic
systems. This safeguards the start-up
of pneumatic systems.
Technical data for soft-start valve with dump function and quick exhaust
Size M2 M3
Connection G� G� G� G� G� G�
Type of mounting In-line installation; combination: flanged
Mounting position Vertical ±5°
Standard nominal flow
rate*
qnN [l/min]
HEM(S)-M-... 2400 3600 3800 3600 3800 3800
Supply
voltage
(HEM(S)-M-...-10 024) 24 V DC
(HEM(S)-M-...-10 110) 110 V AC
(HEM(S)-M-...-10 230) 230 V AC
Input pressure range 2 ... 10 bar (2 to 16 bar)
Protection class (DIN 40 050) IP 65 (with plug socket)
Duty cycle 100%
Temperature range –10 ... +50 °C
Materials Housing: aluminium; sealing plug: nylon; seals: NBR
Weight (with pressure gauge) 1.046 kg 1.471 kg
* Measured at p1 = 6 bar and �p = 1 bar
10.2
Technical data
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-49Festo AG & Co.
Soft-start valves HEM/HEMSM-series service units
HEM-M2-G�-... HEM-M2-G�-... Characteristic curves for flow rate*
Standard flow rate qn [l/min]
Differentialpressure[bar]
Standard flow rate qn [l/min]
Differentialpressure[bar]
HEM-M2-G�-...
Standard flow rate qn [l/min]
Differentialpressure[bar]
p1 = 10 bar
10.2
Type code
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-50 Festo AG & Co.
Soft-start valves HEM/HEMSM-series service units
Function
HEM = Soft-start valve
with dump function and
quick exhaust
Series
M = Modular
Size
2 = Size 2
3 = Size 3
Thread type
G = G thread
Connection size
� = G�
� = G�
� = G�
� = G�
Options
024 = 24 V DC
110 = 110 V AC
230 = 230 V AC
Input pressure range
10 = 2 ... 10 bar
16 = 2 ... 16 bar
H E M M— —
1 2 3 4 5 6 7
—
8 9 10 11 12 13 14 15 16 17
10.2
Dimensions
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-51Festo AG & Co.
Soft-start valves HEM/HEMSM-series service units
Input pressure range 2 ... 10 bar
1 Mounting bracket HW (not
included in scope of delivery)
2 Plug to DIN 43 650 type A
3 Pipe connector LVR (not
included in scope of delivery)
4 Regulating screw for flow
control valve
5 Connecting thread for quick
exhaust
6 Manual override,
resetting
7 Manual override,
by pushing or turning with
detent
� Flow direction
Input pressure range 2 ... 16 bar
Without manual override (type HEMS)
Input pressure range 2 ... 16 bar
HEM-M2/M3-...
Type B1 B2 B3 B4 B5 B6 B7 B8 B9 D1 D3 D5 L1 L2 L3 L4 L6 L7
HEM-M2-... 60 60 3.5 40 2 69 88 3 128 G� G� 7 170 77 46 108.5 41.5 49
HEMS-M2-... G�
G�
HEM-M3-... 73 73 3.5 40 2 82 101 3 141 G� G� 7 170 77 46 108.5 41.5 49
HEMS-M3-... G�
G�
10.2
Technical data
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-52 Festo AG & Co.
Soft-start valves HELM-series service units
G� ... G� HEL-M-...
pneumatic
The soft-start valve is installed in a
compressed air system to actively
control pressure build-up during
start-up.
– For remote pneumatic control of
system pressure
– Drives are moved slowly and safely
to their initial positions
– Sudden and unexpected move-
ments are avoided
– For exhausting, input 1 must be
unpressurised
Pressurep
Operating pressure p2 (= p1)
Start signal Gradual pres-
sure build-up
Time t
Switching timedelay
Technical data for soft-start valve
Size M2 M3
Connection G� G� G� G� G� G�
Type of mounting In-line installation; combination: flanged
Mounting position Vertical ±5°
Standard nominal flow qnN [l/min]
rate* HEL-M-... 2400 3600 4500 3600 4500 4500
Input pressure range 2 ... 16 bar
Temperature range –10 ... +80 °C
Materials Housing: aluminium; sealing plug: nylon; seals: NBR
Weight (with pressure gauge) 0.584 kg 0.736 kg
* Measured at p1 = 6 bar and �p = 1 bar
10.2
Technical data
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-53Festo AG & Co.
Soft-start valves HELM-series service units
HEL-M2-G�-... HEL-M2-G�-... Characteristic curves for flow rate*
Standard flow rate qn [l/min]
Differentialpressure[bar]
Standard flow rate qn [l/min]
Differentialpressure[bar]
HEL-M2-G�-...
Standard flow rate qn [l/min]
Differentialpressure[bar]
* p1 = 10 bar
10.2
Type code
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-54 Festo AG & Co.
Soft-start valves HELM-series service units
Function
HEL = Soft-start valve
Series
M = Modular
Size
1 = Size 1
2 = Size 2
Thread type
G = G thread
Connection size
� = G�
� = G�
� = G�
� = G�
Options
000 = Pneumatic
actuation
Pressure range
16 = 2 ... 16 bar
H E L M— —
1 2 3 4 5 6 7
—
8 9 10 11 12 13 14 15 16 17
10.2
Dimensions
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-55Festo AG & Co.
Soft-start valves HELM-series service units
With pneumatic
actuation
HEL-M2/M3-...
1 Mounting bracket type HW-...
(not included in scope of
delivery)
2 Pipe connector LVR (not
included in scope of delivery)
3 Regulating screw for flow
control valve
� Flow direction
Type B1 B2 B4 B5 B6 B7 B8 B9 D1 D5 H1 H2 L1 L2 L6 L7
HEL-M2-... 60 60 40 2 69 88 3 128 G� 7 80 35 72 26.5 41.5 49
G�
G�
HEL-M3-... 73 73 40 2 82 101 3 141 G� 7 80 35 72 26.5 41.5 49
G�
G�
10.2
Technical data
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-56 Festo AG & Co.
Branching modules FRMM-series service units
G� ... G� Branching module
FRM-M-...
– Pneumatic manifold with 4 connec-
tions, attachment facility for auxili-
ary modules
– The pneumatic manifold has an
outlet top and bottom
– Variants: with PE converter fitted
underneath
– Branching module for distribution
of compressed air
– Several additional air connections
for greater flexibility
– Pressure switch can be mounted for
monitoring
– Can be used as intermediate
distributor for varying air qualities
Type codes
Branching module
FRM-...
Function
FRM =
Branching module Series
M = Modular
Size
1 = Size 1
2 = Size 2
3 = Size 3
Thread type
G = BSP
Connection size
� = G�
� = G�
� = G�
Options
Y = PEV-�-B-OD
Z = PEV-�-SC-OD
with display
F R M M— —
1 2 3 4 5 6 7
—
8 9 10 11 12 13 14
Technical data for branching module
Size M1 M2 M3
Connection G� G� G�
Type of mounting Combination: flanged
Mounting position Any
Standard nominal flow
rate*
qnN [l/min]
FRM-M-... 2800 10 000 21 000
Input pressure Max. 21 bar
Temperature range –10 ... +80 °C
Materials Housing: aluminium
Weight 0.128 kg 0.264 kg 0.439 kg
* Measured at p1 = 6 bar and �p = 1 bar
10.2
Dimensions
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-57Festo AG & Co.
Branching modules FRMM-series service units
1 Piping connector with mounting
bracket LVRH-M1 (not included
in scope of delivery)
2 Plug connector to DIN 43 650
5 Pressure switch PEV-�-B-OD
� Flow direction
FRM-M1-...
Type B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 D1 D2 D3 D5 L1 L2 L3 L4 L6 L7 L8 L9 L13
FRM-M1-G� 40 42.6 21.3 40 – 40 56 2 83 2.2 G� G� G� 5.5 36 18 123 5 45 35 – – 100
FRM-M2/M3-...
2 Plug connector to DIN 43 650
3 Mounting bracket HW (not
included in scope of delivery)
4 Piping connector LVR (not
included in scope of delivery)
5 Pressure switch PEV-�-B-OD
6 Double nipple ESK-�-�
� Flow direction
Type B1 B2 B3 B4 B5 B6 B7 B8 B9 D1 D2 D3 D5 L1 L2 L3 L4 L6 L7 L13
FRM-M2-G� 48 60 30 40 2 57 76 3 116 G� G� G� 7 48 24 140 5 41.5 49 –
FRM-M3-G� 66 73 36.5 40 2 75 94 3 134 G� G� G� 7 48 24 140 6 41.5 49 –
10.2
Technical data
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-58 Festo AG & Co.
Membrane air dryers LDM-series service units
G� Membrane air dryer
for atmospheric dew point –40 °C
LD-M-...-STD
for atmospheric dew point –20 °C
LD-M-...-ECO
– Optimum terminal membrane dryer
– Membrane dryer with high
functional reliability
– Flow rate-dependent dew point
reduction
– Wear-free function without external
energy
Some typical application areas with
higher compressed air drynesshigher compressed air dryness
requirements:
– Drying, cleaning of precision parts
– Purging of measuring glasses,
measuring technology
– Painting systems
Compressed air always contains mois-
ture. A characteristic measure of
moisture content is the dew point.
Many of these increased require-
ments for compressed air quality can
be met by using membrane air dryers.
To ensure operational safety, it is
necessary to pre-filter the compressed
air with an LFM micro filter (0.01 µm).
Technical data for membrane air dryer
Size M3
Connection G�
Type of mounting In-line installation, mounting bracket;
Combination: flanged
Mounting position Vertical ±5°
Standard nominal flow
rate*
qn [l/min] Cartridge size 1 Cartridge size 2 Cartridge size 3 Cartridge size 4
( ) For atmospheric dew pointLD-M3-G�-STD-1/2/3/4 STD 100 (40) 200 (80) 400 (160) 600 (240)
(...) For atmospheric dew point
–40 °C LD-M3-G�-ECO-1/2/3/4 ECO 50 100 200 300
Purge air requirement [l/min] STD 25(10) 50(20) 100(40) 150(60)
(...) For atmospheric dew point
–40 °CECO 8 14 30 34
Atmospheric dew point
with LD-...-STD-1/2/3/4 –20 °C (–40 °C)
with LD-...-ECO-1/2/3/4 –20 °C
Input pressure range 4 ... 10 bar
Temperature range +5 ... +50 °C
Materials Housing: die-cast Zn; metal bowl: aluminium; cartridge: glass fibre; seals: NBR
Weight 1.4 kg 1.6 kg 1.9 kg 2.4 kg
* Measured at p1 = 7 bar and t = 21 °C
10.2
Type code
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-59Festo AG & Co.
Membrane air dryers LDM-series service units
Function
LD = Membrane
air dryer Series
M = Modular
Size
3 = Size 3
Thread type
G = G thread
N = NPT thread
Connection size
� = G�
Options
1 = Cartridge size 1
2 = Cartridge size 2
3 = Cartridge size 3
4 = Cartridge size 4
Atmospheric dew point
STD = Standard –40 °C
ECO = Economy –20 °C
L D M— ——
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
3 1 2
10.2
Dimensions
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-60 Festo AG & Co.
Membrane air dryersM-series service units
LD-M-...
1 Mounting bracket HW (not
included in scope of delivery)
2 Pipe connector LVR (not included
in scope of delivery)
� Flow direction
Type B1 B2 L1
LD-M3-G�-...-1 60 37 193
LD-M3-G�-...-2 60 37 263
LD-M3-G�-...-3 74 44 303
LD-M3-G�-...-4 74 44 373
10.2
Technical data
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-61Festo AG & Co.
Service unit combinations LFR/FRCM-series service units
A service unit combination consists of
various individual modules.
Festo M-series service units can be
combined in a modular system by the
user to create a service unit combina-
tion that meets the on-site require-
ments.
Common application examples are
catered for with fully assembled ser-
vice unit combinations. Available with
manual condensate drain or inte-
grated, automatic condensate drain.
-H- Note:
All M-series combinations are fitted
with plastic bowls, including bowl
guards. They also have a regulating
range (p2 = 10 bar) and are fitted
with 40 µm filter cartridges.
Input pressure range Max. 12 bar (p1) LFR-M...-KA, LFR-M...-KB,
LFR-M -KC LFR-M -KEOperating pressure range Max. 10 bar (p2)
LFR-M...-KC, LFR-M...-KE,
LFR-M-...-KF
Temperature range –10 ... +60°C (M1: –10 ... +40°C) FRC-M...-KA, FRC-M...-KB,
FRC-M...-KC
Input pressure range Max. 12 bar (p1) LFR-M...-KD, LFR-M...-KG
FRC-M-...-KE, FRC-M-...-KF
Operating pressure range 2 ... 10 bar
Temperature range –10 ... +50°C
10.2
Technical data
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-62 Festo AG & Co.
Service unit combinations LFR/FRCM-series service units
Individual units
1 Pipe connector LRV-M
2 Manual on-off valve HEA-M
3 Filter regulator LFR-M
4 Mounting bracket HW-M
5 Connector LV-M
6 Branching module FRM-M
7 Lubricator LOE-M
8 Pressure regulator LR-M
9 Soft-start valve HEM-M
aJ Pressure switch PEV and double
nipple ESK-�-�
1
2
3
4
5
6
8
7
69
aJ
10.2
Dimensions
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-63Festo AG & Co.
Service unit combinations LFRM-series service units
LFR-M-...-KA
Size Connec-
tion
Standard
nominal flow
rate*
[l/min]
M1 G� 750
M2 G� 1750
G� 3900
M3 G� 4000
* Measured at p1 = 10 bar, p2 = 6 bar
and �p = 1 bar
Type B1 B10 D1 H1 H2 H3 L1 L2 L5
min.
T1 T2
LFR-M1-...-KA 86 40 5.5 100 35 45 165 66 33 41 87
LFR-M2-...-KA 124 64.5 7 98 41.3 41.3 253 93 59 41 105
LFR-M3-...-KA 158 77.5 7 98 41.3 41.3 289 104 85 48 120
LFR-M-...-KB
Size Connec-
tion
Standard
nominal flow
rate*
[l/min]
M1 G� 750
M2 G� 1800
G� 3800
M3 G� 3800
* Measured at p1 = 10 bar, p2 = 6 bar
and �p = 1 bar
Type B2 B11 B12 D1 H1 H2 H3 L1 L2 L5
min.
T1 T2
LFR-M1-...-KB 126 40 40 5.5 100 35 45 165 66 33 41 87
LFR-M2-...-KB 182 53.5 69 7 98 41.3 41.3 253 93 59 41 105
LFR-M3-...-KB 225 62.5 82 7 98 41.3 41.3 289 104 85 48 120
10.2
Dimensions
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-64 Festo AG & Co.
Service unit combinations LFRM-series service units
LFR-M-...-KC
Size Connec-
tion
Standard
nominal flow
rate*
[l/min]
M1 G� 670
M2 G� 1600
G� 4000
M3 G� 4000
* Measured at p1 = 10 bar, p2 = 6 bar
and �p = 1 bar
Type B3 B11 D1 H1 H2 H3 L1 L2 L5
min.
T1 T2
LFR-M1-...-KC 80 40 5.5 100 35 45 165 66 33 41 87
LFR-M2-...-KC 118 53.5 7 98 41.3 41.3 253 93 59 41 105
LFR-M3-...-KC 140 62.5 7 98 41.3 41.3 289 104 85 48 120
LFR-M-...-KD
Size Connec-
tion
Standard
nominal flow
rate*
[l/min]
M2 G� 1300
G� 1800
M3 G� 2000
* Measured at p1 = 10 bar, p2 = 6 bar
and �p = 1 bar
Type B4 B10 D1 H1 H2 H3 L1 L2 L5
min.
L8 T1 T2
LFR-M2-...-KD 149 64.5 7 98 41.3 41.3 253 93 59 150 41 105
LFR-M3-...-KD 185 77.5 7 98 41.3 41.3 289 104 85 150 48 120
10.2
Dimensions
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-65Festo AG & Co.
Service unit combinations LFRM-series service units
LFR-M-...-KE
Size Connec-
tion
Standard
nominal flow
rate*
[l/min]
M1 G� 750
M2 G� 1750
G� 3900
M3 G� 4000
* Measured at p1 = 10 bar, p2 = 6 bar
and �p = 1 bar
Type B1 B10 D1 H1 H2 H3 L1 L2 L5
min.
T1 T2 T3
LFR-M1-...-KE 86 40 5.5 100 35 45 165 66 33 41 87 106
LFR-M2-...-KE 124 64.5 7 98 41.3 41.3 253 93 59 41 105 106
LFR-M3-...-KE 158 77.5 7 98 41.3 41.3 289 104 85 48 120 113
LFR-M-...-KF
Size Connec-
tion
Standard
nominal flow
rate*
[l/min]
M1 G� 750
M2 G� 1800
G� 3800
M3 G� 3800
* Measured at p1 = 10 bar, p2 = 6 bar
and �p = 1 bar
Type B2 B11 B12 D1 H1 H2 H3 L1 L2 L5
min.
T1 T2 T3
LFR-M1-...-KF 126 40 40 5.5 100 35 45 165 66 33 41 87 106
LFR-M2-...-KF 182 53.5 69 7 98 41.3 41.3 253 93 59 41 105 106
LFR-M3-...-KF 225 62.5 82 7 98 41.3 41.3 289 104 85 48 120 113
10.2
Dimensions
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-66 Festo AG & Co.
Service unit combinations LFRM-series service units
LFR-M-...-KG
Size Connec-
tion
Standard
nominal flow
rate*
[l/min]
M2 G� 1300
G� 1800
M3 G� 1800
* Measured at p1 = 10 bar, p2 = 6 bar
and �p = 1 bar
Type B7 B11 B13 D1 H1 H2 H3 L3 L4 L5
min.
L8 T1 T2 T3
LFR-M2-...-KG 251 53.5 126 7 98 41.3 41.3 284 124 59 150 41 105 106
LFR-M3-...-KG 307 62.5 157 7 98 41.3 41.3 309 124 85 150 48 120 113
10.2
Dimensions
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-67Festo AG & Co.
Service unit combinations FRCM-series service units
FRC-M-...-KA
Size Connec-
tion
Standard
nominal flow
rate*
[l/min]
M1 G� 400
M2 G� 1400
G� 2900
M3 G� 3200
* Measured at p1 = 10 bar, p2 = 6 bar
and �p = 1 bar
Type B6 B10 B15 D1 H1 H2 H3 L1 L2 L5
min.
L6
min.
L7 T1 T2
FRC-M1-...-KA 120 40 40 5.5 100 35 45 165 66 33 58 88 41 87
FRC-M2-...-KA 186 64.5 57 7 98 41.3 41.3 253 93 59 96 153 41 105
FRC-M3-...-KA 230 77.5 75 7 98 41.3 41.3 289 85 85 125 179 48 120
FRC-M-...-KB
Size Connec-
tion
Standard
nominal flow
rate*
[l/min]
M1 G� 400
M2 G� 1400
G� 2900
M3 G� 3200
* Measured at p1 = 10 bar, p2 = 6 bar
and �p = 1 bar
Type B6 B10 B15 D1 H1 H2 H3 L1 L2 L5
min.
L6
min.
L7 T1 T2 T2
FRC-M1-...-KB 120 40 40 5.5 100 35 45 165 66 33 58 88 41 87 106
FRC-M2-...-KB 186 64.5 57 7 98 41.3 41.3 253 93 59 96 153 41 105 106
FRC-M3-...-KB 230 77.5 75 7 98 41.3 41.3 289 104 85 125 179 48 120 113
10.2
Dimensions
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-68 Festo AG & Co.
Service unit combinations FRCM-series service units
FRC-M-...-KC
Size Connec-
tion
Standard
nominal flow
rate*
[l/min]
M1 G� 400
M2 G� 1400
G� 3000
M3 G� 3200
* Measured at p1 = 10 bar, p2 = 6 bar
and �p = 1 bar
Type B7 B11 B13 D1 H1 H2 H3 L1 L2 L5
min.
L6
min.
L7 T1 T2 T3
FRC-M1-...-KC 160 40 80 5.5 100 35 45 165 66 33 58 88 41 87 106
FRC-M2-...-KC 244 53.3 126 7 98 41.3 41.3 253 93 59 96 153 41 105 106
FRC-M3-...-KC 297 62.5 157 7 98 41.3 41.3 289 104 85 125 179 48 120 113
FRC-M-...-KE
Size Connec-
tion
Standard
nominal flow
rate*
[l/min]
M2 G� 1000
G� 1500
M3 G� 1700
* Measured at p1 = 10 bar, p2 = 6 bar
and �p = 1 bar
Type B8 B10 B12 D1 H1 H2 H3 L3 L4 L5
min.
L6
min.
L7 L8 T1 T2
FRC-M2-...-KE 218 64.5 69 7 98 41.3 41.3 284 124 59 96 153 150 41 105
FRC-M3-...-KE 250.5 77.5 82 7 98 41.3 41.3 309 124 85 125 179 150 48 120
10.2
Dimensions
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-69Festo AG & Co.
Service unit combinations FRCM-series service units
FRC-M-...-KF
Size Connec-
tion
Standard
nominal flow
rate*
[l/min]
M2 G� 1000
G� 1600
M3 G� 1800
* Measured at p1 = 10 bar, p2 = 6 bar
and �p = 1 bar
Type B9 B11 B14 D1 H1 H2 H3 L3 L4 L5
min.
L6
min.
L7 L8 T1 T2 T3
FRC-M2-...-KF 340 53.5 207 7 98 41.3 41.3 284 124 59 96 153 150 41 105 106
FRC-M3-...-KF 403 62.5 246 7 98 41.3 41.3 309 124 85 125 179 150 48 120 113
10.2
Technical data
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-70 Festo AG & Co.
Service unit combinations LFRM-series service units
Characteristic curves for flow rate* LFR-M2-G�-KA-... LFR-M2-G�-KB-...
Standard flow rate qn [l/min]
Outputpressurep2
[bar]
Standard flow rate qn [l/min]
Outputpressurep2
[bar]
LFR-M2-G�-KC-... LFR-M2-G�-KD-...
Standard flow rate qn [l/min]
Outputpressurep2
[bar]
Standard flow rate qn [l/min]
Outputpressurep2
[bar]
LFR-M2-G�-KE-... LFR-M2-G�-KF-...
Standard flow rate qn [l/min]
Outputpressurep2
[bar]
Standard flow rate qn [l/min]
Outputpressurep2
[bar]
LFR-M2-G�-KG-...
Standard flow rate qn [l/min]
Outputpressurep2
[bar]
* p1 = 10 bar
10.2
Technical data
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-71Festo AG & Co.
Service unit combinations FRCM-series service units
FRC-M2-G�-KA-... FRC-M2-G�-KB-... Characteristic curves for flow rate*
Standard flow rate qn [l/min]
Outputpressurep2
[bar]
Standard flow rate qn [l/min]
Outputpressurep2
[bar]
FRC-M2-G�-KC-... FRC-M2-G�-KE-...
Standard flow rate qn [l/min]
Outputpressurep2
[bar]
Standard flow rate qn [l/min]
Outputpressurep2
[bar]
FRC-M2-G�-KF-...
Standard flow rate qn [l/min]
Outputpressurep2
[bar]
* p1 = 10 bar
10.2
Mounting accessories
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-72 Festo AG & Co.
Service unit accessoriesM-series service units
Mounting bracketg
HWF-...
(holder for individual units
with bowls)
Part No. Type For function unit/type Size For connection
183 865 HWF-M1 LF, LFM, LOE, LFR M1 G�, G�
Angle bracket HWR-M1 HWR-M2/M3g
HWR-...
(holder for
pressure regulator)
Part No. Type For function unit/type Size For connection
183 868 HWR-M1 LR, LRB, LFR M1 G�, G�
183 869 HWR-M2 M2 G�, G�, G�
183 870 HWR-M3 LR, LFR M3 G�, G�, G�
Mounting bracket
HW-...
(universal bracket on connector LV-...)
Part No. Type For function unit/type Size For connection
183 871 HW-M2/M3 All function units M2, M3 G�, G�, G�, G�
10.2
Mounting accessories
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-73Festo AG & Co.
Service unit accessoriesM-series service units
LV-... LVH-M1 LVH-M2/M3 Connector
LV-...
Connector with mounting bracket
LVH-...
Part No. Type For function unit/type Size For connection
183 872 LV-M1 All function units M1 G�, G�
183 873 LV-M2/M3 M2, M3 G�, G�, G�, G�
183 874 LVH-M1 All function units M1 G�, G�
183 875 LVH-M2/M3 M2, M3 G�, G�, G�, G�
LVR-M1 LVRH-... Piping connector for fixed pipingp g p p g
(2 pieces)
LVR-...
Piping connector with mounting
bracket
LVRH-...
Part No. Type For function unit/type Size For connection
183 876 LVR-M1-G�-SET All function units M1 G�
183 877 LVR-M1-G�-SET G�
183 878 LVR-M1-G�-SET G�
183 890 LVRH-M1-G�-SET All function units M1 G�
183 891 LVRH-M1-G�-SET G�
183 892 LVRH-M1-G�-SET G�
LVR-M2/M3 Piping connector for fixed pipingp g p p g
LVR-...
Part No. Type For function unit/type Size For connection
183 882 LVR-M2/M3-G� All function units M2, M3 G�
183 883 LVR-M2/M3-G� G�
183 884 LVR-M2/M3-G� G�
183 885 LVR-M2/M3-G� G�
10.2
Mounting accessories
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-74 Festo AG & Co.
Service unit accessoriesM-series service units
Pressure gauge
MA-...
Part No. Type For function unit/type Size For display range
183 896 MA-23-6-R� LR, LFR, FRC M1 0 ... 6 bar
183 897 MA-23-10-R�
, ,
0 ... 10 bar
183 898 MA-23-16-R� 0 ... 16 bar
183 899 MA-40-6-G�-EN* LR, LFR, FRC (per EN 837-1) M2, M3 0 ... 6 bar
183 900 MA-40-10-G�-EN*
, , (p 37 ) , 3
0 ... 10 bar
183 901 MA-40-16-G�-EN* 0 ... 16 bar
183 902 MA-40-25-G�-EN* 0 ... 25 bar
187 078 MA-40-6-R�-EN* Specially designed for LRB with M1, M2 0 ... 6 bar
187 079 MA-40-10-R�-EN*
p y g
coated R thread (per EN 837/1)
,
0 ... 10 bar
187 080 MA-40-16-R�-EN*
(p / )
0 ... 16 bar
187 081 MA-40-25-R�-EN* 0 ... 25 bar
* Per EN 837-1
Sturdy mounting ring
HMR-...
made of aluminium for control panel
installation of regulators
Part No. Type For function unit/type Size For connection
183 925 HMR-M1-ALU LR, LRB M1 G�, G�
183 926 HMR-M2-ALU
,
M2 G�, G�, G�
183 927 HMR-M3-ALU LR M3 G�, G�, G�
Regulator adjustment lock
(for LR, LRB, LFR, FRC)
LRVS-...
The regulator adjustment lock is fitted
under the regulator head (regulator
head must be removed). When the
LRVS is installed, the set pressure
cannot be changed.
Part No. Type For function unit/type Size For connection
183 928 LRVS-M1 LR, LRB, FR, FRC M1 G�, G�
183 929 LRVS-M2
, , ,
M2 G�, G�, G�
183 930 LRVS-M3 LR, LFR, FRC M3 G�, G�, G�
10.2
Mounting accessories
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-75Festo AG & Co.
Service unit accessoriesM-series service units
Lubricator protective cover
LOEVS-...
Part No. Type For function unit/type Size For connection
183 931 LOEVS-M1/M2/M3 LOE M1, M2, M3 G�, G�, G�, G�, G�
1 µm, 0.01 µm5 µm, 40 µm
LFM...LFP... LFMPX...
0.003 mg/m3
Filter cartridge
LFP...
LFM...
Part No. Type For function unit/type Size Grade of filtration
183 910 LFPC-M1 LF M1 5 µm
183 911 LFPC-M2 M2
183 912 LFPC-M3 M3
183 913 LFPE-M1 LF M1 40 µm
183 914 LFPE-M2 M2
183 915 LFPE-M3 M3
183 916 LFMPB-M1 LFM M1 1 µm
183 917 LFMPB-M2 M2
183 918 LFMPB-M3 M3
183 919 LFMPA-M1 LFM M1 0,01 µm
183 920 LFMPA-M2 M2
183 921 LFMPA-M3 M3
183 922 LFMPX-M1 LFM M1 Active carbon 0.003 mg/m3
183 923 LFMPX-M2 M2 max. residual oil content
183 924 LFMPX-M3 M3
10.2
Mounting accessories
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-76 Festo AG & Co.
Service unit accessoriesM-series service units
HWF-M1
(for LF, LFM, LOE, LFR)
HWR-M1
(for LR, LRB, LFR)
HWR-M2/M3
(for LR, LRB, LFR)
Type B1 B2 B4 B5 B6 B7 B8 D5 L6 L7
HWR-M2 28 18.5 40 2.7 42.0 70 8 7 57 66.5
HWR-M3
5
49
7
47.6 76
7 57 5
HW-M2/M3
10.2
Mounting accessories
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-77Festo AG & Co.
Service unit accessoriesM-series service units
LV-M1
(for all types)
LV-M2/M3
LVH-M1
(for all types)
LVH-M2/M3
Type B9
LVH-M2 69
LVH-M3 82
10.2
Mounting accessories
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-78 Festo AG & Co.
Service unit accessoriesM-series service units
LVR-M1
Type D1
LVR-M1-G�-SET G�
LVR-M1-G�-SET G�
LVR-M1-G�-SET G�
LVR-M2/M3
Type B1 B2 D1
LVR-M2 128 90.4 G�9
G�
G�
G�
LVR-M3 141 103.4 G�3 3
G�
G�
G�
10.2
Mounting accessories
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-79Festo AG & Co.
Service unit accessoriesM-series service units
LVRH-M1
Type D1
LVR-M1-G�-SET G�
LVR-M1-G�-SET G�
LVR-M1-G�-SET G�
LVRH-M1-G�-SET G�
LVRH-M1-G�-SET G�
LVRH-M1-G�-SET G�
MA-23-...
for LFR-M1, LR-M1, FRC-M1
MA-40-...-G����-EN
for LFR-M2/M3, LR-M2/M3, FRC-
M2/M3
MA-40-...-R����-EN
for LRB-M1/M2
10.2
Mounting accessories
Products 2001 – Subject to change – 01/04Vol.3 / 10.2-80 Festo AG & Co.
Service unit accessoriesM-series service units
Pressure switch
PEV ����-B-0D
Adjustable pressure switching point
and hysteresis, without plug socket
Order code
175 250 PEV�-B-0D
Pressure switch
PEV ����-SC-0D
Adjustable pressure switching point
Hysteresis is finely adjustable with
visual scale, without plug socket
Order code
161 760 PEV�-SC-0D
Double nipple
ESK-...
Adjustable for angular compensation
Order code
151 521 ESK-�-�
Electronic pressure sensor
SDE1
For pressure monitoring on D or M series
service units
Order code
192 026 SDE-D10-G2-R18-C-P1-M8
192 027 SDE-D10-G2-R18-C-P2-M8
192 028 SDE-D10-G2-R14-C-P1-M8
192 029 SDE-D10-G2-R14-C-P2-M8
10.2
Mounting accessories
01/04 – Subject to change – Product 2001 Vol.3 / 10.2-81Festo AG & Co.
Service unit accessoriesM-series service units
Plug socket
MSSD-...
for PEV-�-...
Order code
171 157 MSSD-C-4P
Plug socket
PEV-...
with integrated LED
Order code
164 274 PEV-�-WD-LED-24
164 275 PEV-�-WD-LED-230
10.2