UTL-2011-M05 HVAC

Post on 14-Feb-2016

23 views 1 download

Tags:

description

hiuh

Transcript of UTL-2011-M05 HVAC

IR.TJETJENG SOFJAN S, MM, IAIPROGRAM STUDI ARSITEKTUR FAKULTAS TEKNIK UNIVERSITAS

BANDARLAMPUNG

A heating, ventilation and air conditioning (HVAC) system is used to heat and cool a house/ buildings.In the summer, the heat pump acts like an air conditioner, moving heat from inside your home to the outside.During winter months, heat from outdoors is transferred to the interior of your home/ rooms

HVAC SYSTEM (HEATING, VENTILATION and

AIR-CONDITIONING) PADA HAKEKATNYA ADALAH SUATU SISTEM PENGENDALIAN TEMPERATUR RUANGAN YANG TERINTEGRASI,YAITU SEBAGAI PENGHANGAT RUANGAN (HEATING SYSTEM), VENTILASI UDARA RUANGAN (VENTILATION SYSTEM) DAN PENDINGIN RUANGAN (AIR CONDITIONING SYSTEM) > DI NEGARA 4 MUSIM

DI INDONESIA, KARENA BERIKLIM TROPIS (HANGAT/ PANAS LEMBAB), YANG BANYAK DIGUNAKAN HANYA AIR CONDITIONERAIR CONDITIONER UNTUK PENDINGINAN UDARA.

WHAT IS HVAC ?In The Summer

In The Winter

HEATINGHEATING HEATING > PEMANASAN & PERTUKARAN

UDARA DALAM RUANGAN YANG DINGIN (MISAL DI NEGARA 4 MUSIM)

NATURAL DG. PERAPIAN MEKANIS DG. ALAT PEMANAS/HEATER/

HEATING AIR CONDITONER PADA BANGUNAN DI DAERAH TROPIS,

HEATING JARANG DIGUNAKAN.

VENTILATIONVENTILASI > VENTILASI > SIRKULASI/PERTUKARAN SIRKULASI/PERTUKARAN

UDARA (UNTUK KEBUTUHAN O2 DAN UDARA (UNTUK KEBUTUHAN O2 DAN PERTUKARAN PANAS)PERTUKARAN PANAS)

• NATURAL VENTILATIONNATURAL VENTILATION• NATURAL VENTILATION MEMANFAATKAN

TEKANAN UDARA ALAMI & SIRKULASI UDARA DARI LUAR

• TIPE, LOKASI & BESARAN LUBANG VENTILASI HARUS MENGOBSERVASI SERTA MEMAHAMI SIFAT-SIFAT UDARA DI SEKITARNYA

• VENTILASI ALAMI MURAH, TANPA SUARA MAUPUN BIAYA PERAWATAN

• MECHANICAL VENTILATIONMECHANICAL VENTILATION• MEMANFAATKAN KIPAS UNTUK

MENSIRKULASIKAN UDARA • TIPE, LOKASI & BESARAN KIPAS (DI

PLAFON,DINDING, AXIAL ATAU ROOF FAN) HARUS DIRENCANAKAN AGAR EFEKTIF DAN TIDAK MENGGANGGU AKTIVITAS

AIR CONDITIONINGAIR CONDITIONINGAIR CONDITIONING > > PENGKONDISIAN UDARA PENGKONDISIAN UDARA

(SUHU, SIRKULASI/PERTUKARAN UDARA)(SUHU, SIRKULASI/PERTUKARAN UDARA) DALAM RUANGAN SECARA MEKANIS. DI DAERAH TROPIS ADALAH PENDINGINAN UDARA

• CENTRAL AIR CONDITIONERCENTRAL AIR CONDITIONER• PENGKONDISIAN UDARA UNTUK BANGUNAN

SECARA TERPUSAT (KAPASITAS BESAR)• MENGGUNAKAN DUCTING UNTUK

MENYALURKAN UDARA• FRESH AIR INLET OTOMATIS MEMUNGKINKAN

PENAMBAHAN O2

• WINDOW/ SPLIT AIR CONDITIONER WINDOW/ SPLIT AIR CONDITIONER • PENGKONDISIAN UDARA SECARA PARTIAL PER-

RUANGAN (KAPASITAS KECIL) • TIDAK MEMERLUKAN DUCTING• PERHATIKAN FRESH AIR INLET (PENAMBAHAN

UDARA SEGAR/ O2 DALAM SIRKULASI TATA UDARA)

• PADA AC WINDOW MASIH ADA FRESH AIR INLET• PADA AC SPLIT TIDAK ADA FRESH AIR INLET

FUNGSI & MANFAAT AC

MANFAAT: PENYEGARAN UDARA UNTUK KENYAMANAN ORANG

MEMBERIKAN KENYAMANAN TERHADAP PENGGUNA RUANGAN

PENYEGARAN UDARA UNTUK INDUSTRI MENCIPTAKAN KONDISI UDARA YANG SESUAI UNTUK

KINERJA SUATU KEGIATAN/ PROSES PRODUKSI/ MESIN/ PERALATAN

FUNGSI:1. MENGATUR DAN MENYESUAIKAN SUHU UDARA

DI DALAM RUANG2. MENJAGA DAN MENGATUR KELEMBABAN

UDARA.3. MELAKUKAN PERTUKARAN UDARA DAN

MENSIRKULASIKAN UDARA YANG TELAH ADA DI DALAM RUANG YANG SUDAH DIBERIKAN PENGATURAN UDARA.

5. MENYARING DAN MEMBERSIHKAN UDARA

PERENCANAAN AC

KEBUTUHAN PERTUKARAN & KONDISI UDARA

STANDAR KEBUTUHAN UDARA PERHITUNGAN KAPASITAS AC TIPE, KARAKTERISTIK &

PERALATAN AC PERANCANGAN SISTEM AC KEBUTUHAN RUANGAN UNTUK

PERALATAN AC DESAIN ARSITEKTURAL PENGHEMATAN ENERGI

KEBUTUHAN UDARA

KEBUTUHAN UDARA

Volume ruang/udara Perbedaan

temperatur & temperatur yg diinginkan

Faktor pengaruh: Panas & Radiasi

sinar matahari Induksi panas dari

ruangan lain Panas dari tubuh

manusia Panas dari sumber

cahaya (lampu) Panas dari

peralatan/ mesin

BEBAN PENDINGINAN

Cara Sederhana Perhitungan Kapasitas AC: Kebutuhan BTU= (W x H x I x L x E) / 60   W =  Panjang Ruang (dalam feet)

H  =  Tinggi Ruang (dalam feet)I   =  Nilai 10 jika ruang berinsulasi (berada di lantai bawah, atau

berhimpit dengan ruang lain).           Nilai 18 jika ruang tidak berinsulasi (di lantai atas).L  =  Lebar Ruang (dalam feet)E  =  Nilai 16 jika dinding terpanjang menghadap utara; Nilai 17 jika menghadap timur; Nilai 18 jika menghadap

selatan; dan nilai 20 jika menghadap barat.

1 Meter  =  3,28 Feet  Rata-rata Kapasitas AC berdasarkan PK :

 AC ½ PK    =  ±  5.000 BTU/h; AC 1½ PK  =  ±12.000 BTU/h AC ¾ PK    =  ±  7.000 BTU/h; AC 2 PK     =  ±18.000 BTU/h AC 1 PK     =  ±  9.000 BTU/h; Dst (lihat spec.tiap merk AC)     

Contoh Hitungan:Ruang berukuran 9m x 4m atau (29 kaki x 13 kaki), tinggi ruangan 3m (10 kaki) tidak berinsulasi, dinding panjang menghadap ke timur. Kebutuhan BTU = (29 x 13 x 18 x 10 x 17) / 60 = 19.227 BTU alias cukup dengan AC 2 P

PERHITUNGAN KAPASITAS AC

DIRECT COOLINGDIRECT COOLING (Tata Udara Langsung)Udara didinginkan dan disalurkan langsung tanpa saluran udara/ ducting. AC WINDOW (0,5 – 2 PK) AC SPLIT (0,5- 3PK) AC PACKAGE ( 2-10 PK) AC SPLIT DG MINI DUCTING

INDIRECT COOLING INDIRECT COOLING ( Tata Udara Tidak Langsung)Udara didinginkan dan disalurkan melalui saluran udara/ ducting. AC CENTRAL (kapasitas sangat besar)AC CENTRAL (kapasitas sangat besar)

AIR COOLEDAIR COOLED WATER COOLEDWATER COOLED

TIPE/JENIS AC

AC WINDOW PADA AC WINDOW, SEMUA

PERALATAN PENDINGIN MULAI DARI KOMPRESOR, KONDENSOR, EVAPORATOR DAN BLOWER DITEMPATKAN MENJADI SATU ( DALAM SATU BOX).

SELAIN MENSIRKULASIKAN UDARA DALAM RUANGAN, PADA AC WINDOW MASIH ADA UDARA SEGAR (FRESH AIR) YANG DITAMBAHKAN, SEHINGGA KEBUTUHAN TAMBAHAN O2 MASIH TERPENUHI.

AC SPLIT PADA AC SPLIT, PERALATAN KOMPRESOR,

KONDENSOR DILETAKAN DILUAR RUANGAN SEDANGKAN EVAPORATOR DAN BLOWER DITEMPATKAN DIDALAM RUANGAN.

UNTUK AC SPLIT YANG BERKAPASITAS BESAR, 1 OUTDOOR UNIT BISA DIGUNAKAN UNTUK BEBERAPA RUANGAN (EVAPORATOR)

AC SPLIT JUGA ADA YANG DILENGKAPI DENGAN MINI DUCTING, DENGAN DIFFUSER MIRIP AC-CENTRAL

AC CENTRALUNIT AC CENTRAL

SECARA GARIS BESAR TERDIRI DARI:

OUT DOOR : COOLING TOWER CONDENSING

UNIT CHILLER

INDOOR: AIR HANDLING

UNIT (AHU) DUCTING DIFFUSER (INLET

& OUTLET)

SISTEM PLENUM ADALAH PENYALURAN UDARA TANPA DUCTING, MENGGUNAKAN RUANG DIATAS PLAFON

PERHATIKAN KEAMANAN DAN KEBERSIHAN

JANGAN MELALUI RUANGAN YANG KOTOR/PANAS (RUANG ME, DLL)

JIKA UDARA DIRESIRKULASI, JANGAN ADA SALURAN AIR KOTOR/ GAS DALAM RUANG PLAFON

AC CENTRAL – SISTEM SIRKULASI UDARA TANPA DUCTING OUTLET (plenum system)

AC CENTRAL - SISTEM SIRKULASI UDARA ZONA TUNGGAL CONSTANT VOLUME

AC CENTRAL – SISTEM DUCTING ZONA TUNGGAL (CV) PENGATURAN UDARA

ZONA TUNGGAL, UDARA YANG DIMASUKAN KE DALAM RUANGAN VOLUMENYA TETAP (CONSTANT VOLUME/CV)

AC CENTRAL - SISTEM SIRKULASI UDARA ZONA TUNGGAL VARIABLE VOLUME

AC CENTRAL – SISTEM DUCTING ZONA TUNGGAL (VV) PENGATURAN UDARA

ZONA TUNGGAL, UDARA YANG DIMASUKAN KE DALAM RUANGAN VOLUMENYA BERUBAH (VARIABLE VOLUME/VV)

AC CENTRAL - SISTEM SIRKULASI UDARA ZONA GANDA

AC CENTRAL – SISTEM DUCTING ZONA GANDA (VV) PENGATURAN UDARA

ZONA GANDA, UDARA YANG DIMASUKAN KE DALAM RUANGAN VOLUMENYA TIDAK TETAP (VARIABLE VOLUME/VV)

RUANG AHU – SINGLE

RUANG AHU – MULTI FLOOR

MODEL RUANG AHU

DUCTING

LINIER TRUNK SYSTEM RADIAL TRUNK SYSTEM

DUCTING

MODELMODEL

DIFFUSER

CHILLER ACCHILLER AC

Mini Chiller (1 -20 PK)

Hermetic Air Cooled (10 -100 PK)

Scroll Air Cooled (15-150 TR)

Scroll Water Cooled(50-150 TR)

Centrifugal Water Cooled(250-6000 TR)Screw Air Cooled(150-

515 TR)

COOLING TOWER

GAMBAR INSTALASI AC (SPLIT)

CENTRAL ACCENTRAL AC

water cooled

air cooled water cooled

EEFISIENSI FISIENSI EENERGINERGI ISOLASI DINGIN: ISOLASI SELURUH JALUR DINGIN/

BEJANA DENGAN MENGGUNAKAN KETEBALAN ISOLASI YANG EKONOMIS UNTUK MEMINIMALKAN KEHILANGAN PANAS; DAN PILIHLAH BAHAN ISOLASI YANG COCOK (BENAR).

PEMBUNGKUS GEDUNG: MENGOPTIMALKAN VOLUME PENYEJUKAN UDARA (AC) DENGAN PENGUKURAN SEPERTI PENGGUNAAN ATAP-ATAP PALSU DAN PEMISAHAN AREA KRITIS UNTUK PENYEJUKAN UDARA AC DENGAN TABIR UDARA.

MEMINIMALKAN BEBAN PANAS GEDUNG: MEMINIMALKAN BEBAN PENYEJUK UDARA (AC) DENGAN CARA SEPERTI PENDINGINAN ATAP, PENGECATAN ATAP, PENERANGAN YANG EFISIEN, PENDINGINAN AWAL UDARA SEGAR DENGAN PENUKAR PANAS UDARA KE UDARA, SISTIM VARIABEL VOLUM UDARA, PENYETELAN OPTIMAL SUHU THERMO-STATIC RUANG BER AC, PENERAPAN LAPISAN MATAHARI, DLL.

MINIMISASI BEBAN PANAS PROSES:

UNTUK SKYSCRAPPER BUILDING, AIR CONDITIONING SYSTEM KOVENSIONAL DENGAN MESIN CHILLER YG MENYEDOT ENERGI LEBIH DARI 60% LISTRIK TERPASANG, SEKARANG MULAI DITINGGALKAN DAN DIGANTI DENGAN SISTEM AIR CONDITIONING YANG MEMANFAATKAN ENERGI PANAS, MATAHARI, GAS DAN BAHKAN ENERGI DARI SAMPAH YANG LEBIH RAMAH LINGKUNGAN

EEFISIENSI FISIENSI EENERGINERGI

FAKTA

EEFISIENSI FISIENSI EENERGINERGI

ARCHITECTURAL DESIGN

SELESAI