Post on 03-Jun-2020
VMS-006-DX1
User Manual
2 3
n Veho DX-1 Microscope
n Adjustable cradle stand
n SoftwareCD
n Quick start guide
n Calibrationruler
n Cleaningcloth
What’s in the box?Introduction
TheVehoDX-1microscopeallowsyoutoexplorethemicroscopicworld.Highlyusefulforstudents,teachers,laboratoryresearch,medicalanalysis,repairservicesorhobbyists.
Pleasetakeamomenttoreadthroughthismanualtoensureyougetthemostoutofthemicroscope.Keepthismanualsafeforfuturereference.
Beforeusingthemicroscope,pleasereadthesafetyprecautionsbelow.Alwaysensure thattheunitisoperatedcorrectly:
n TheDX-1microscopeisnotwaterproof
n Useandstorewithinacool,dryenvironment(-5°C–50°C),avoidusingindampconditions
n Donotpointthelenstowardsthesunorastronglightsource,thismaydamage the microscope
n Avoidtouchingthelens,unlesswiththesuppliedcleaningcloth
n DonotstaredirectlyintotheLEDs;theymaydamageyoureyes
If you require assistance or have any questions about the DX-1 Microscope, please contact us through our Live Chat on our website at:
veho-world.com
4 5
Assembling the DX-1 Microscope
1 2 3 4
‘Click’
Positionthecradlestanduprightwiththelockingnuttightened.
Alignfixingpointsonmicroscopewithfixings
oncradle.
Gentlypushmicroscopeuntilclicks
intoplace.
Theangleofthecradle canbeadjustedbyundoing
thelockingnut.
Focus WheelAdjuststhefocusofthemicroscope on the object
Brightness Wheel Adjust the brightness ofthe8LED’s
Cradle StandFullyadjustablealloystand
Locking NutLoosentoadjusttheangleof thestand,onceinpositiontightenthenut
Guide to the DX-1 Microscope
2
4
3
1
1
2
3
4
6 7
ToinstalltheMicroCapturePlussoftware,usethesuppliedsoftwareCDorvisitourwebsitedownloadareaat:
veho-world.com/downloadsOncedownloadedontoyourdesktop,double-clicktheinstallbuttonfor‘MicroCapturePlus’andaccepttoinstallthesoftwareontoyourPC;theinstallationwillbegin.
Installing microscope software
Operating system requirements
n Windows-7/8/10 MacOS-10.12andlater
n P41.8orabove
n RAM 1GB
n VideoMemory126M
n USBport2.0
PluginthemicroscopebeforeopeningMicroCapturesoftware.Onceconnected,openMicroCapturesoftwaretostartusingthemicroscope.
Ifthemicroscopeisnotrecognisedorhasbeendisconnectedanotificationwillbedisplayed.
Connecting the DX-1 Microscope
8
Focusing the microscope
9
Tofocusthemicroscoperotatethefocuswheelonthefrontofthemicroscope;clockwisetozoom-in oranti-clockwisetozoomout.Usingthesoftware,youwillbeabletoseeonscreenwhethertheDX-1 isfocused.
Captureastillphotoorvideofootageatanypointwhenusingthemicroscope,usetheiconsordropdownmenuwithintheMicroCapturePlussoftware.
Settingandpreferencescanalsobeadjustedwithinthesoftware,theseinclude:
n Resolution
n Dateandtime
n Interfacelanguage
n Full-screen mode
n Timerforphoto/videocapture
Using the software
10 11
Calibration
Ensure‘DisplayCrossing’isturnon,goto‘Options>XYGuide>On/Off’.
Themicroscopewilldefaulttocrossing‘On’,werecommendthatthisislefton.
Step 1 Focus the microscope on the suppliedcalibrationruler,adjustthemagnificationwheeluntilthepictureisclear.TakeapictureoftheselectedareawhentherulerlinesareparalleltotheblueXYguides,asshownintheimage.
Step 2 Double-click on the image captured to enter the measurement interface.
Step 3 Once the image is open, click on thecalibrationicon.Usingthemouse,clickonthebeginningandendingpoints;youmustknowthedistancebetweenthepoints(usingtheruler).Adialogueboxwillpopup,entertheexactvalueofthemeasurementinto‘Actualdimension’.Thesoftwarewillautomaticallycalibratethemagnificationrate.Click‘OK’andtheadjustedmagnificationratewillshowintheupperrightcorner.
Step 4Nowusing‘AnyAngleLine’,under the measurement icon, measure thesamedistanceagain.Ifthevaluemeasuredisapproximatelythesameastheactualvalue,thencalibrationhasbeensuccessful.
Calibration & Measurements
12 13
Measurements
Double-click on the image to enter the measurementinterface.Underthe‘Measurement’icon,chooseanyofthefollowingoptionstomeasure.
Any Angle Line Measurement Clickandholdfromonepointanddragtothenextpoint,thenrelease.
Continuous Line MeasurementAllowsyoutomeasureanycontinuouslength.Click,holdanddragfromonepointtootherpoints,thenrelease.
Radius Circle MeasurementClick,holdandextendouttothechosenradius.Theradius,circumferenceandareaofthecirclewillbecalculated.
Diameter Circle MeasurementClick,holdandextendouttothechosendiameter.Thediameter,circumferenceandareaofthecirclewillbecalculated.
Three Points Angle Measurement Select anythreepoints,theanglevalueswillbecalculatedanddisplayed.
14 15
Changing Calibration
Usethefollowingstepstochangecalibrationsettings.
1. Double-clicktoopentheimage,clickthe‘Calibration’icon,andselect‘ResetMagnification’andthen‘ResetPictureMagnification’.Thenstartcalibrationagain.
2. Changethemagnificationrateandcaptureseveralimages, click on the image to enter measurement interface.Select‘SetMagnification’then‘SetPictureMagnification’,adialogueboxwillappear;enteryourchosenmagnificationrateandclick‘OK’.
3. Ifyouwanttousethesamemagnificationratetocapturepictures,click‘SetMagnification’then‘SetCaptureMagnification’tosavesettings.Allpictureswillusethesamemagnificationrate.
Youcanannotatecapturedimagesusingthedraworaddtextfeatures;thisisusefulwhenusingforlateranalysis.
1. Clickthepencilicontobringupthedrawingdropdownlist.Selectyourpreferredtool,andstartdrawingontheimage.
2. Clickthetexticontoaddwritingtoyourcapturedimage.Fromthedropdownselectyourpreferredfont,sizeandtextcolour.
Adding drawing and text
16 17
Specif ications
Image sensor 2MegaPixels
Photo resolution 1920x1080,1280x720,640x480
Video resolution 1920x1080,1280x720,640x480
Focus range Manualfocusfrom0mmto150mm
Magnification ratio 10xor200x
Video format AVI
Photo format JPEG
Light source 8LEDs(brightnessadjustable)
PC interface USB2.0
Power source 5VDCfromUSBport
System requirements Windows7/8/10,Mac10.12andlater
Languages English,German,Spanish,Russian,Italian,French,Portuguese,Dutch,Polish,Japanese,Korean,Chinese
Bundle software MicroCapturePlus(withmeasurementforWin/Mac)
Dimensions Microscope:110mmx33mm
Troubleshooting
Problem Solution
Photocaptureorvideoisblurredorshaky Theimageisnotinfocus,correctthisbyturningtheFocusWheel. Usethemicroscopestandwhencapturingimagestoavoidshake.
Microscopedoesnotturnon TryadifferentUSBport. DownloadtheMicroCapturePlussoftware.
Screenisblank Ensurethatthesoftwareisopenandthescopeispluggedin. Checktheitemyouwanttoviewispositionedcorrectlyunderthe lens.Ensurethescopeisfocused.
Imagelookssmudgedorblurred Cleanthescreenandlenscarefullywithsuppliedcloth.
If these do not solve your problem please contact us via our Live Chat on our website at:
veho-world.com
IntheeventyouneedtocontactVehoforsupportortroubleshootingfor yourVehoDX-1Microscope,pleasecontactusviaourLiveChatonourwebsiteat:
veho-world.com
Support