Post on 31-Oct-2020
www.ealar
m.com.m
y
www.ealar
m.com.m
y
Copyright © 2011 AASMSB Co. No. 135844-U. All Rights Reserved
CONTENT
Layout LCD & Indicate Symbol 1
Layout LCD (Additional) 2
LED Layout 3
Away Arming 4
Home Arming 6
System Disarm 8
Bypass Zone 9
Review Event Memory 10
Walk-Test or System Test 11
Fire Alarm 12
Panic Alarm 12
Medical Alarm 12
Duress Alarm 13
Programming User Codes 14
Deleting User Codes 14
Programming Telephone Numbers 15
Deleting Telephone Numbers 15
Programming Timers 16
Activate Automatic Arm Away Function 17
Restricting Installer Code 18
Call-In Voice Menu 19
Call-Out Voice Menu 20
Call-In Voice Menu (Diagram) 21
Call-Out Voice Menu (Diagram) 22
Quick Operation Reference 23
www.ealar
m.com.m
y
Copyright © 2011 AASMSB Co. No. 135844-U. All Rights Reserved1
AWAY1 - Systempartition1inAWAYarmmodeAWAY2 - Systempartition2inAWAYarmmodeHOME1 - Systempartition1inHOMEarmmodeHOME2 - Systempartition2inHOMEarmmodeREADY1 - Systempartition1inDisarmModeREADY2 - Systempartition2inDisarmModeNOTRDY1 - Partition1anyzoneisopenandwhenarmingthesystem,thezoneopenwill autobypassNOTRDY2 - Partition2anyzoneisopenandwhenarmingthesystem,thezoneopenwill autobypassOnline - PanelistocallouttoCMS/PersonalBatt - WhenBatterylow,thiswilldisplay,buzzerkeypadwillsoundand EVENTLighton.Tostopbuzzerkeypadsoundjustpress*andtoclear EVENTlightjustdisarm.Ac - WhenACPowerfailure,thiswilldisplayandbuzzerkeypadwillsoundand EVENTlighton.Tostopbuzzerkeypadsoundjustpress*andtoclear EVENTlightjustdisarm.
Indicate symbol
LightOn ZoneLightBlink
LightBlink ZoneLightOn
BuzzerSound Speaker
LCD Layout (Default)
www.ealar
m.com.m
y
Copyright © 2011 AASMSB Co. No. 135844-U. All Rights Reserved 2
AWAY1 - SysteminAWAYarmmodeforpartition1AWAY2 - SysteminAWAYarmmodeforpartition2HOME1 - SysteminHOMEarmmodeforpartition1HOME2 - SysteminHOMEarmmodeforpartition2READY1 - SysteminDisarmModeforpartition1READY2 - SysteminDisarmModeforpartition2NOTRDY1 - Anyzoneisopenandwhenarmingthesystem,thezoneopenwillautobypass forpartition1NOTRDY2 - Anyzoneisopenandwhenarmingthesystem,thezoneopenwillautobypass forpartition2Online - PanelistocallouttoCMS/PersonalBatt - WhenBatterylow,thiswilldisplay,buzzerkeypadwillsoundand EVENTLighton.Tostopbuzzerkeypadsoundjustpress*andtoclear EVENTlightjustdisarm.Ac - WhenACPowerfailure,thiswilldisplayandbuzzerkeypadwillsoundand EVENTlighton.Tostopbuzzerkeypadsoundjustpress*andtoclear EVENTlightjustdisarm.
Layout LCD (Additional)
www.ealar
m.com.m
y
Copyright © 2011 AASMSB Co. No. 135844-U. All Rights Reserved3
LINE -Systemiscallout.
-Whenlighton,SystemiscalltoCMS
-Whenlightblinking,SystemiscalltoPersonal
BATT -Whenlighton,indicatesBatterylow
AC -Whenlighton,indicatesACPowerfailure
ARM1 -Partition1systemarm
ARM2 -Partition2systemarm
-Awayarm
-Homearm
LED Layout
1 2 3 4 5 6 7 8 9 10
Numberingistoindicatezone
www.ealar
m.com.m
y
Copyright © 2011 AASMSB Co. No. 135844-U. All Rights Reserved 4
Away Arming
Press[ * ] + [ AWAY ](IfQuickAwayoptionisenabled)OrPress[ * ] + [ AWAY ] + [ Common/Partition 1/Partition 2 User Code](IfQuickAwayoptionisdisabled)
LeavethepremiseswithintheExittime.ExitbeepingwillcontinueuntilExittimeexpires.OnlineatLCDkeypad/LINEatLEDkeypadtoindicatesystemdiallerperformingCMSreporting/Personalreporting..
Partition 1 Keypad
Partition 2 Keypad
Common Partition Keypad
Valid Valid Valid CommonUserCode CommonUserCode CommonUserCode -arm/disarmbothpartition -arm/disarmbothpartition -arm/disarmpartition2 Partition1UserCode Partition1UserCode Partition2UserCode -arm/disarmpartition1 -arm/disarmpartition1 -arm/disarmpartition2
TheARMLightwillturnon TheARM1/ARM2Lightwillturnon
www.ealar
m.com.m
y
Copyright © 2011 AASMSB Co. No. 135844-U. All Rights Reserved5
• Awayarmingwillactivateallzonesofyouralarmsecuritysystemexceptbypassedzones. Allinteriorandexternalperimetersarearmed.Usethismodewhenleavingyourpremises.• BeforearmingyoursystemtoAwaymode,allzonesshouldbeclosed.Thereshouldnotbe anymovementintheroomsprotectedbymotiondetectorsandeachdoororwindowprotected byreedswitchesshouldbeproperlyclosed.• Key-switchinputisavailableonthecontrolpanelandcanbeusedtotogglebetweenArm andDisarm.• Your system can be configured to Arm periodically at a customized time and also Disarm at anothertime.• IfanillegalcodeisenteredtoArminAwaymode,thesystemrespondsbyalongerrorbeep.• IfanattempttoArmapreviouslyarmedsystem,alongerrorbeepisissued.• ThesystemcannotArmwhileinotheroperationmode.Press[*]+[*]toexitfromother operation mode first.
Options to be programmed by Installer:• PersonalOpen/Closereport: If anyone of User-6 to User-10 arms in Away mode, the system will dial the first programmedtelephonenumber(usuallytheMasterUser’scontactnumber)toreportthe Arm activity to the intended receiving party. Personal reporting format must be enabled first.• NoForcedArm: ThesystemwillnotbeallowedtoArmviakeypadifanInstantzoneisleftopenexcept Delayzone.Alongerrorbeepisissuedtowarnyouofsuchsituation.IfyouwantForced Armfunction,anyzonesleftopenafterarmingwillbeautomaticallybypassedandare reportedtoCMSasZoneBypassandtoPersonaltelephoneasZoneOpen.Thesystem willresumemonitoringthezoneonceitisclosedagainforthedurationofthatarmedperiod.• ForcedArmSirenWarning: ThesirenwillcontinuouslysoundorsquawktoindicateaForcedArmsituation.Youshould Disarmthepanel,checkthepremisesandthenArmagain.Continualwarningscouldmean thereisaproblemwithadetectiondeviceandthatparticularzonemayhavetobemanually bypassed.• AwaySquawk: SirenwilloutputtwosquawksuponarmingthesysteminAwaymodeandoutputasingle squawkwhenthesystemisdisarmed.• NoArmIfBatteryLow: YoumaynotArmthesystemiftheback-upbatteryisdeterminedaslowandACpoweris notpresent.• ExitBeep: KeypadbeeperwillbeepcontinuouslyforthedurationofExittime.Pleaseconsultyourinstallertoenabletheaboveoption!
Information:
www.ealar
m.com.m
y
Copyright © 2011 AASMSB Co. No. 135844-U. All Rights Reserved 6
Home Arming
Press[ * ] + [ HOME ](IfQuickHomeoptionisenabled)OrPress[ * ] + [ HOME ] + [ Common/Partition 1/Partition 2 User Code](IfQuickHomeoptionisdisabled)
TheARMlightwillblink. TheARM1lightwillblink.
Valid Valid Valid CommonUserCode CommonUserCode CommonUserCode -arm/disarmbothpartition -arm/disarmbothpartition -arm/disarmpartition2 Partition1UserCode Partition1UserCode Partition2UserCode -arm/disarmpartition1 -arm/disarmpartition1 -arm/disarmpartition2
Partition 1 Keypad
Partition 2 Keypad
Common Partition Keypad
www.ealar
m.com.m
y
Copyright © 2011 AASMSB Co. No. 135844-U. All Rights Reserved7
Information:
• HomeArmingwillonlyactivateexternalperimeterportionofyouralarmsecuritysystem. Interiorprotectionisnotarmed,whichallowsmovementwithinpremiseswithoutcausingalarm. Usethismodewhenyouareinthepremises.• YourinstallermustprogramwhichzonestobeactiveinHomearmingmode.• IfanillegalcodeisenteredtoArminHomemode,thesystemrespondsbyalongerrorbeep.• IfanattempttoArmapreviouslyarmedsystem,alongerrorbeepisissued.• ThesystemcannotArminHomemodewhileinotheroperationmode.Press[*]+[*]toexit fromotheroperationmode.
Options to be programmed by Installer:• PersonalOpen/Closereport: If anyone from User-6 to User-10 arms in Home mode, the system will dial the first programmedtelephonenumber(usuallytheMasterUser’scontactnumber)toreportthe Arm activity to the intended receiving party. Personal reporting format must be enabled first.• NoForcedArm: ThesystemwillnotbeallowedtoArmviakeypadifanInstantzoneisleftopenexcept Delayzone.Alongerrorbeepisissuedtowarnyouofsuchsituation.IfyouwantForced Armfunction,anyzonesleftopenafterarmingwillbeautomaticallybypassedandare reportedtoCMSasZonebypassandtoPersonaltelephoneasZoneopen.Thesystem willresumemonitoringthezoneonceitisclosedagainforthedurationofthatarmedperiod.• ForcedArmSirenWarning: ThesirenwillcontinuouslysoundorsquawktoindicateaForcedArmsituation.Youshould Disarmthepanel,checkthepremisesandthenArmagain.Continualwarningscouldmean thereisaproblemwithadetectiondeviceandthatparticularzonemayhavetobemanually bypassed.• HomeInstant: AllzoneswillautomaticallyconvertintoInstantzonesifArminHomemode.• HomeSquawk: SirenwilloutputtwosquawksuponarmingthesysteminHomemodeandoutputasingle squawkwhenthesystemisdisarmed.• NoArmIfBatteryLow: YoumaynotArmthesystemiftheback-upbatteryisdeterminedaslowandACpoweris notpresent.Pleaseconsultyourinstallertoenabletheaboveoption!www.ea
larm.co
m.my
Copyright © 2011 AASMSB Co. No. 135844-U. All Rights Reserved 8
System Disarm
Press[ User Code ] TheLINE,BATT,AC,ARM1,ARM2lightswillblinkonce.TheARMlightwillturnoff. TheARM1lightwillturnoff.
Information:• Disarmingthealarmsecuritysystemwilldeactivatealltheburglaryzonesofthesystem.• EnterthepremisesthroughaprogrammeddelayzoneanddisarmthesystembeforeEntry timeisover.IfthesystemisnotdisarmedbytheendoftheEntrytime,analarmwilloccur.• Duringdisarmedmode,anyviolatedzoneswillnotenableburglaryalarmexcept24-hourzone. The24-hourzonesareactiveirrespectivewhetherthesystemisunderarmedordisarmed status.• Disarmingthesystemalsoresetstriggeredsirenandstrobelight.• Key-switchinputisavailableonthecontrolpanelandcanbeusedtotogglethesystemtoArm andDisarmalternately.• ApreviouslyarmedsystemwouldnotDisarmifanillegalUsercodeisentered.Youmayhave upto20triesofcontinualkeyentryofthecorrect4-digitcodeinsequencebeforethekeypad goesintoalock-outperiodof10seconds.
Options to be programmed by Installer:• PersonalOpen/Closereport: If anyone from User-6 to User-10 disarms, the system dials the first programmed telephone numbertoreporttheDisarmactivityandwhichUsercodeisusedtotheintendedreceiving party. Personal reporting format must be enabled first.• EntryBeep: KeypadbeeperwillbeepcontinuouslyforthedurationofEntrytime.• Chime: AbeeptoindicateazoneisopenedduringsystemDisarmstate.Thisfunctionistemporarily canceledduringArmstate.Pleaseconsultyourinstallertoenabletheaboveoption!
Partition 1 Keypad
Partition 2 Keypad
Common Partition Keypad
www.ealar
m.com.m
y
Copyright © 2011 AASMSB Co. No. 135844-U. All Rights Reserved9
Bypass Zone
1)Press[ * ] + [ BYPASS ] (IfQuickBypassisenabled) Or
Press [ * ] + [ BYPASS ] + [ User Code ] (IfQuickBypassisdisabled)
2)Press[ Zone Number ]
3)Press[ * ]toexitBypassmode
TheLINElightwillturnofftoindicateexitfromBypassmode.
3beepstoindicateexitfromBypassmode.
Remark:Pressdigit‘09’tobypassorun-bypasszone09.Whenpress“#+BYPASS”/”BYPASS”willshowthebypasszone
Information:• Bypassisperformedtoeliminateburglaryzonesthatarenotreadyorfaultyfromactivating burglaryalarm.Protectiontoabypassedzoneistemporarilyswitchedoffuntilthenext systemarming.• Toun-bypasspreviouslybypassedzones,simplyDisarmthesystemtocancelbypassstateof allzonesorenterbypassmodeandpressthecorrespondingbypassedzonenumbertotoggle itsbypassstatetoun-bypassstate.Afterun-bypassingazone,thebypassindicationwillbe removedfromthatparticularzone.• Nobypassorun-bypassofzonesisallowedduringsystemArm.• ThesystemcannotenterBypassmodewhileinotheroperationmode.Press[ * ] + [ * ]toexit fromotheroperationmode.
www.ealar
m.com.m
y
Copyright © 2011 AASMSB Co. No. 135844-U. All Rights Reserved 10
Numberingdisplaywillindicatezonetriggered TheLINElightwillblinktoindicate Reviewmode. TheZONElightwillturnontoindicate anyzonetriggered.
Blinkingzonelightindicateslatest zonetriggered.
Press[ * ] + [ REVIEW ] (IfQuickReviewisenabled) Or
Press[ * ] + [ REVIEW ] + [ User Code ] (IfQuickReviewisdisabled)
Press [ 0 ]tocleartheeventmemory. Or
Press[ * ]toexitReviewmode.
TheLINElightwillturnofftoindicateexitfromReviewmode. 3beepstoindicateexitfromReviewmode.
Information:• Inthismode,thekeypadcandisplayallfaultedzonesafteranalarmconditionhasoccurred. Thefaultedzoneswillremaininthesystemmemoryuntiltheyareclearedbyenteringdigit‘0’ orwhenthenextarmingoccursoraftersystemreset.• YoumaynotenterRevieweventmodeviakeypadifthesystemisinArmstate.• ThesystemcannotenterRevieweventmemorymodewhileinotheroperationmode. Press[ * ] + [ * ]toexitfromotheroperationmode.
Review Event Memory
www.ealar
m.com.m
y
Copyright © 2011 AASMSB Co. No. 135844-U. All Rights Reserved11
TheLINElightwillblinktoindicate Walk-testmode. Therespectivezonelightwillturnon toindicatethezoneistested.
1)Enter [ * ] + [ 5 ] + [ User Code ]2)Triggerallusedzones.
3)Press [ 1 ]toactivatesiren
[ 2 ]toactivatestrobelight
Pressthesamedigitagaintoswitchoffrespectivealarmoutput.
4)Press [ * ]toexitWalk-testmode
TheLINElightwillturnofftoindicateexitfromWalk-testmode.
Information:• Walk-testallowsallzones,sirenandstrobetobetestedforfunctionality.PerformWalk-test periodicallytoensurethesystemisinaworkingcondition.• Ensureallzonesareclosedandthereisnoonewithinthepremisesbeforeconducting Walk-test.• Walk-testmodeisnotallowedduringsystemArm.
System Test
Enter [ * ] + [ 8 ] + [ User Code ]
LCDKeypad“Online”willshowsystemiscalloutLEDKeypadTheLINElightturnsontoindicatesystemdiallerperformingCMSreporting.TheLINElightblinkstoindicatesystemdiallerperformingPersonalreporting.
Information:• SystemtestsendsatestreporttoCMSandPersonaltelephonenumber(whicheverreporting modeisenabled).• Pleaseinformyourinstallertoactivatethisfunctionifyouwishtoperformthisoperation.
Walk-Test
www.ealar
m.com.m
y
Copyright © 2011 AASMSB Co. No. 135844-U. All Rights Reserved 12
Press [ * ] + [ 3 ]
LCDKeypad“Online”willshowsystemiscalloutLEDKeypad
TheLINElightturnsontoindicatesystemdiallerperformingCMSreporting.
TheLINElightblinkstoindicatesystemdiallerperformingPersonalreporting.
Panic Alarm
Press [ * ] + [ 6 ]
LCDKeypad“Online”willshowsystemiscalloutLEDKeypad
TheLINElightturnsontoindicatesystemdiallerperformingCMSreporting.
TheLINElightblinkstoindicatesystemdiallerperformingPersonalreporting.
Medical Alarm
Press [ * ] + [ 9 ]
LCDKeypad“Online”willshowsystemiscalloutLEDKeypad
TheLINElightturnsontoindicatesystemdiallerperformingCMSreporting.
TheLINElightblinkstoindicatesystemdiallerperformingPersonalreporting.
Information:• TheFire,Panic,Medicalalarmswillactivatethesystemdiallertoreportofanemergencyas wellasactivatingthesirenandstrobelightoutput.• TheFire,PanicandMedicalalarmscanbeactivatedatalltimes,duringsystemArmorDisarm.• YoucanenteryourUsercodetocancelthetriggeredsirenandstrobelightoutput.• Key-switchinputisavailableonthecontrolpanelandcanbeusedtoactivatePanicalarmif enabled.• IfyoursystemcannotperformFire,Panic,Medicalalarmfunctions,itmeansthatthesystemis inotheroperationmode.Press[ * ] + [ * ]toexitfromotheroperationmodebeforeattempting emergencyalarm.
Fire Alarm
www.ealar
m.com.m
y
Copyright © 2011 AASMSB Co. No. 135844-U. All Rights Reserved13
Press[ Last Digit of User Code + 1 ]
LCDKeypad“Online”willshowsystemiscalloutLEDKeypad
TheLINE,BATT,AC,ARM1,ARM2lightswillblinkonce.
TheLINElightturnsontoindicatesystemdiallerperformingCMSreporting.
TheLINElightblinkstoindicatesystemdiallerperformingPersonalreporting.
TheARM1lightwillturnoff.
Remark:Duresscode=LastdigitofUsercodeincreaseby1
E.g1. Usercode=1234 Duresscode=1235
E.g2. Usercode=9999 Duresscode=9990
Information:• DuresscodeisusedtoDisarmthesystemandtransmitanemergencysignaltotheCentral MonitoringStationorPersonaltelephonenumberdiscreetlytoindicatethereisaduress situation.ThisisimportantifyouarebeingforcedtoDisarmyoursystemagainstyourwill.• DuressalarmcanalsobeactivatedduringDisarmstate.• ForCMSreportformat,anyUsercodeusedtoactivateDuressalarmwillbereported.• ForPersonalreportformat,onlyUser-6toUser-10codescanactivateDuressalarmandthe emergency will be reported to the first Personal telephone number. Duress signal and which UsercodeusedtoDisarmthesystemwillbeannounced.User-1toUser-5codesusedfor DuresspurposewillonlyDisarmthesystem.• Key-switchinputisavailableonthecontrolpanelandcanbeusedtoactivateDuressalarmif enabled.ThismethodwillnotDisarmapreviouslyarmedsystembutwillreporttoaCentral MonitoringStationorPersonaltelephonenumberdiscreetly.• ApreviouslyarmedsystemwouldnotDisarmifanillegalDuresscodeisentered.Youmay haveupto20triesofcontinualkeyentryofthecorrect4-digitDuresscodebeforethekeypad goesintoalock-outperiodof10seconds.
Duress Alarm
www.ealar
m.com.m
y
Copyright © 2011 AASMSB Co. No. 135844-U. All Rights Reserved 14
1)Press[ * ] + [ 7 ] + [ Master Code ]
2)Enter3-digitaddresslocation [ ] [ ] [ ]
3)Enteranew4-digitUsercode[ ] [ ] [ ] [ ]
3beepstoindicateanew4-digitcodeisentered.
4)Press[ * ]toexitProgrammingmode
Deleting User Codes
1)Press[ * ] + [ 7 ] + [ Master Code ]
2)Enter3-digitaddresslocation[ ] [ ] [ ]
3)Press[ # ]
3beepstoindicatecodeisdeleted.
4)Press[ * ]toexitProgrammingmode
Information:• User-2isdesignatedasInstallercode.Youarenotallowedtoprogramorchange Installercode.• Allzonelightsofftorepresentdigit‘0’onkeypad.
Programming User Codes
3-Digit Address Location User Type Level
401 MasterUser/User-1 Priority 403 User-3 Priority 404 User-4 Priority 405 User-5 Priority 406 User-6 Nonpriority 407 User-7 Nonpriority 408 User-8 Nonpriority 409 User-9 Nonpriority 410 User-10 Nonpriority
www.ealar
m.com.m
y
Copyright © 2011 AASMSB Co. No. 135844-U. All Rights Reserved15
1)Press[ * ] + [ 7 ] + [ Master Code ]
2)Enter3-digitaddresslocation [ ] [ ] [ ]
3)Enteranewtelephonenumber[ ] [ ] [ ] … [ ]
4)Press [ * ] tostorenewtelephonenumber
3beepstoindicateanewtelephonenumberisentered.
5)Press[ * ]toexitProgrammingmode
Deleting Telephone Numbers
1)Press[ * ] + [ 7 ] + [ Master Code ]
2)Enter3-digitaddresslocation[ ] [ ] [ ]
3)Press[ # ]
3beepstoindicatethetelephonenumberisdeleted.
4)Press[ * ]toexitProgrammingmode
Information:• Assignall4telephonenumbersexclusivelytothetop4priorityUsers.• Itisrecommendedthatalltelephonelocationsmustbeprogrammed.
Programming Telephone Numbers
2-Digit Address Location Telephone Number Maximum Digits
709 1st 16
710 2nd 16
711 3rd 16
712 4th 16
www.ealar
m.com.m
y
Copyright © 2011 AASMSB Co. No. 135844-U. All Rights Reserved 16
1)Press[ * ] + [ 7 ] + [ Master Code ]
2)Enter3-digitaddresslocation [ ] [ ] [ ]
3)Enteranew3-digitvalue[ ] [ ] [ ]
3beepstoindicateanew3-digittimevalueisentered.
4)Press[ * ] toexitProgrammingmode
Information:• Alltimervaluesmustbeprogrammedina3-digitformat. Eg.WantedEntryTime=60seconds,Programvalue=‘060’• ProgramallTimerswithintheallowedtimerangeonly.Thefunctionwillnotoperateifaninvalid timeisprogrammed.Refertotheabovetable.• Autodailytestfunctioncanonlybeenabledbyyourinstaller.• ProgramHourandMinutevaluein24-Hourformat.• System time (address locations 517’ and ‘518’) is programmed upon the first powering up of yoursystem.Programthecurrenttimeinhourandminutestoaddresslocations‘517’and518’ respectively.
Example:• ProgramSystemtimeas2.30p.m.(24-Hourformat) Ataddresslocation‘517’,enterHourvalue‘014’andataddresslocation‘518’, enterMinutevalue‘030’• ProgramAutoArmtimeat12.00a.m.(24-Hourformat) Ataddresslocation‘521’,enterHourvalue‘000’andataddresslocation‘522’, enterMinutevalue‘000’• ProgramAutodailytesttimeas9.58a.m.(24-Hourformat) Ataddresslocation‘519’,enterHourvalue‘009’andataddresslocation‘520’, enterMinutevalue‘058’
Programming Timers
3-Digit Address Location Timer Value Default Value Units 513 Entrytime(Partition1) 000-255 045 second 514 Entrytime(Partition2) 000-255 045 second 515 Exittime(Partition1) 000-255 090 second 516 Exittime(Partition2) 000-255 090 second 517 Systemtime(hour) 000-023 000 hour 518 Systemtime(minute) 000-059 000 minute 519 Autodailytest(hour) 000-023 003 hour 520 Autodailytest(minute) 000-059 000 minute 521 AutoArmPartition1(hour) 000-023 255 hour 522 AutoArmPartition1(minute) 000-059 255 minute 523 AutoDisarmPartition1(hour) 000-023 255 hour 524 AutoDisarmPartition1(minute) 000-059 255 minute 829 AutolastHAON(hour) 000-023 000 hour 830 AutolastHAON(minute) 000-059 000 minute 831 AutolastHAOFF(hour) 000-023 000 hour 832 AutolastHAOFF(minute) 000-059 000 minute
www.ealar
m.com.m
y
Copyright © 2011 AASMSB Co. No. 135844-U. All Rights Reserved17
1)Press [ * ] + [ 2 ]
Home-Automationmode
2)Press[ 9 ]
TurnonHomeAutomation“9”
3)Press[ * ]toexitHomeautomationsettingmode.
3beepstoindicateexitfromHomeautomationmode.
Remark:SystemTimemustbeprogrammedbeforehand
Information:• SystemwillautomaticallyArminAwaymodeandDisarmeverydayattheprogrammedtime.• IfyouwishtohaveAuto-ArmonlyandnoAuto-Disarm,simplyprogramaninvalidtimeto addresslocations‘523’and‘524’todisableit.
Activate Automatic Arm Away Function
www.ealar
m.com.m
y
Copyright © 2011 AASMSB Co. No. 135844-U. All Rights Reserved 18
1)Press[ * ] + [ 7 ] + [ Master Code ]
2)Enter3-digitaddresslocation [ 7 ] [ 5 ] [ 8 ]
3)Entera3-digitvalue[ 0 ] [ 1 ] [ 3 ]
3beepstoindicatea3-digitInstallerrestrictvalueisentered.
4)Press [ * ]toexitProgrammingmode
Information:• Tore-enableInstallercodeuse,entervalue‘014’.• Thisisasafetymeasurewherebynoothercodesareallowedtoprogramyoursystem otherthantheusersofthissecurityalarmsystem.
Restricting Installer Code
www.ealar
m.com.m
y
Copyright © 2011 AASMSB Co. No. 135844-U. All Rights Reserved19
1)Dialthetelephonenumberconnectedtothissystem
2)Enter[ User Code ]
3)SystemwilllistoutMainmenuinvoice.Performyourdesiredfunction.
Information:• Thesystemanswersacallfromcallerwhenitdetectstelephonelineringingandthenumber ofringsreachesthenumberprogrammedinthesystembyyourinstaller.• Thecallerwillbepromptedforhis/herUsercode.Thesystemwillenteramainmenu. Alistoffunctionswillbeprompted.Afterperformingyourdesiredfunction,press[*]to hang-up.• AccesstothemainmenuwillbelimitedtopriorityUsersonly.User-6toUser-10 (nonpriorityusers)codeswillbedeniedaccessandpromptedasillegalcodes.• ThesystemwillhangupthecallwhenattemptstoenterthecorrectUsercodeexceeds 8times.Eachincorrectentryofusercodewillcauseavoicepromptindicatingincorrect codeentry.• IfthesystemdoesnotreceiveanycommandkeyentryintheMainmenuforperiodlonger than10seconds,itwillhangupimmediately.• It is recommended to check system status first before proceeding to perform other function soastohaveaclearerunderstandingofthesystem’scurrentstatesuchArmstate, Disarmstate,Openedzones,Bypassedzones,etc.• You may not enter Bypass mode if your system is armed. Disarm first and then enter Bypassmode.• TheCall-infunctioncanbede-activated.Informyourinstallertocancelthisfunction.
Call-In Voice Menu
Key Menu Function 1 AwayArm ArmsysteminAwaymode. 2 HomeArm ArmsysteminHomemode. 3 Disarm/Off Disarmsystemandcancelalarm. 4 Bypass Bypasszone.Enterthezonenumberyouwishtobypassor un-bypass.Press[ * ]toexitthismode. 6 Panic ControlHomeautomationoutput.Entertheoutputnumber youwishtocontrol.Press[ * ] toexitthismode. # Menu BacktoMenu * Hangup EndCall-infunctionandhangup.
www.ealar
m.com.m
y
Copyright © 2011 AASMSB Co. No. 135844-U. All Rights Reserved 20
1) Userpickupcall
AnnounceArm/DisarmactivitybynonpriorityUsers,anytriggeredzonesduringsystem Arm,zonesthatareleftopenuponarming
2) Press [ * ]toenterMainmenu
3) SystemwilllistoutMainmenuinvoice.Performyourdesiredfunction.
Information:• Call-OutfunctionreferstoPersonalreportingformataspartofthefeaturesavailableinyour alarmsecuritysystem.Pleasecheckwithyourinstallerifthisfeatureisenabled.• IfUserpicksupacallandentersMainmenu,thesystemwillnotcallthenextinlinetelephone number.Thesystemwillonlycallthenextnumberwhenuserimmediatelyendsthecallafter listeningtoArm/Disarmstatusoralarmeventorzoneopenstatus.• If the call to the first programmed telephone number has not been picked up, the system will cancelthecallanddialthenexttelephonenumberinline.• ThesystemwillnotperformCall-outfunctiononcethemaximumnumberofgroupdial attemptsprogrammedinthesystemisreachedandnoUser/receivingpartyhaspickedup thecall.• IfthesystemdoesnotreceiveanycommandkeyentryintheMainmenuforperiodlonger than10seconds,itwillhangupimmediately.• YoumayonlybypasszonesifyoursystemisinDisarmstate.
Options to be programmed by Installer:• CallattemptsbeforeFail-to-Communicate: Thesystemwillactivatesirenandstrobelightoutputsonceitfailstoestablish communicationwithaPersonaltelephonenumberaftertheprogrammednumberoffailed callingattemptshasbeenreached.
Call-Out Voice Menu
Key Menu Function 1 AwayArm ArmsysteminAwaymode. 2 HomeArm ArmsysteminHomemode. 3 Disarm/Off Disarmsystemandcancelalarm. 4 Bypass Bypasszone.Enterthezonenumberyouwishtobypassor un-bypass.Press[ * ]toexitthismode. 6 Panic ControlHomeautomationoutput.Entertheoutputnumberyou wishtocontrol.Press[ * ]toexitthismode. # Menu BacktoMenu * Hangup EndCall-outfunctionandhangup.
www.ealar
m.com.m
y
Copyright © 2011 AASMSB Co. No. 135844-U. All Rights Reserved21
Call-In Voice Menu (diagram)
www.ealar
m.com.m
y
Copyright © 2011 AASMSB Co. No. 135844-U. All Rights Reserved 22
Call-Out Voice Menu (diagram)
www.ealar
m.com.m
y
Copyright © 2011 AASMSB Co. No. 135844-U. All Rights Reserved23
AwayArm [*][AWAY][UserCode]HomeArm [*][HOME][UserCode]Disarm [UserCode]Bypass [*][BYPASS][UserCode][ZoneNumber][*]Review [*][REVIEW][UserCode]Walk-test [*][5][UserCode]SystemTest [*][8][UserCode]Firealarm [*][3]Panicalarm [*][6]Medicalalarm [*][9]Duressalarm [LastDigitofUserCode+1]ChangeMasterCode [*][7][MasterCode][4][0][1][NewCode][*]Programtelephonenumber1 [*][7][MasterCode][7][0][9][NewNumber][*][*]Programtelephonenumber2 [*][7][MasterCode][7][1][0][NewNumber][*][*]ProgramEntrytime [*][7][MasterCode][5][1][3][NewTime][*]ProgramExittime [*][7][MasterCode][5][1][5][NewTime][*]ActivateAutoArm [*][2][9][*]EnableAutoLastHomeAutomation[*][2][0][*]Programmingmode [*][7][MasterCode][Address][Value][*]DisplayZone [#][REVIEW]/[REVIEW]DisplayBypass [#][BYPASS]/[BYPASS]
DisclaimerToensureourcustomerreceivesthebestofourservices,wetookanexceptionalamountoftimeandefforttoensurethecorrectnessandaccuracyofthisdocumentation.However,shouldyoufind any information that is in doubt, missing or appear in error, please contact the manufacturer for immediate clarification. We shall not be liable in any way for any such omission and/or inaccuracy.
Weshallnotbeliableorresponsibleforincidentalorconsequentialdamagesunderthefollowingconditions:improperstorage,abnormaluse,abnormalcondition,exposuretoexcessivetemperatureorothersuchenvironmentalconditions,unauthorizedsparepartsinrepairs,misuse,neglect,alteration,improperinstallation,maladjustment,abuse,accident,actofGOD,andspilloffoodsorliquids.
All trademarks used in this documentation are intended for identification only; they are proprietary oftheirrespectiveowners.
Specifications are subject to change without prior notice.
Reproduction,adaptationortranslationinanyformorbyanymeanswithoutpriorwrittenpermissionisprohibited,exceptasallowedunderthecopyrightlaws.
Copyright © 2011 AASMSB Co. No. 135844-U. All Rights Reserved.
QL series V1.1 (QLUM1011-V1.1)
Quick Operation Reference
www.ealar
m.com.m
y
www.ealar
m.com.m
y