Post on 23-Feb-2018
DREXELBROOKDREXELBROOK®
A Leader In Level Measurement Solutions
Universal III™ 509-75 SeriesLevel Transmitter The Universal III smart level
transmitter provides remote calibration without having to empty and fill the vessel.
Configuration Without Changing Level Configure the Universal III quickly and easily before installation or on the vessel without moving the level. Simply key in the calibration data and walk away.
Remote ConfigurationNo longer is it necessary to “sniff” for hazardous gasses or to go out in inclement weather to calibrate your level transmitter. Configure the Universal III from the convenience and comfort of the control room... or anywhere along the two-wire loop.
Quick and Easy CalibrationUse your existing HART® 275 handheld communicator or Drexelbrook’s PC software to configure the transmitter.
Tamper Proof No adjustments on the transmitter; prevents unauthorized “tweaking” or inadvertent changes in calibration.
Unsurpassed AccuracyNo other RF transmitter matches the accuracy, stability, and repeatability of the Universal III. This translates into smoother operation and less downtime.
Compatibility with the FutureThe standard HART protocol is a proven instrumentation protocol. Over a half million field instruments have been supplied by over 70 instrument manufacturers to process plants all over the world. The Universal III is also compatible with Allen Bradley PLCs through their Smart Transmitter Interface products.
One Transmitter for All Applications With RF Admittance technology, one transmitter handles all your applications (Liquids, granulars, slurries, interfaces; cryogenic to 500ºF, full vacuum to 10,000 PSI)
Easiest Calibration EverConfigure this transmitter from anywhere along the two wire-loop without changing the level in the vessel.
Smart Advantages Major advantages of the Universal III:• Ignores Coating Build-Up on Sensing Element
• Built in tank strapping
• Choice of output in level, flow, weight or volume
• Factory precalibration
• Choice of digital or 4-20 mA transmission
• Built-in self diagnostics
�����������������������������
����������������������������
����������������������������������������������������������������
���������������������������
����������
���������
����������
�����������
��������
�������������
����������������������
�������������������
��������
�������
��������
��������������������
�������������������������
� �
���������������������������������������������������������������������������
��������������������
������������������������������
���������������
���������������������
���������������� ����������������������������������������������������������������������������������� ��������������������������������������������������� ����������������������������������
� ��������������������
�����������������������������������������������������
��������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������
�����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������
�������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������
�����������������������������������������������������������������������������������������
���������������������������������������������
������������������������������
���������������������������������������������������������������������
���������������� ���� ���������
���������������������������������������������������������
�������������������������������������������������������
������������������������������������������������������ ��������������������������������� �����
���������������������������������������������������������������������������������������������
�������������������������������������������������������������������������������������
�����������������������������������������������������
�������������������
���������������������
��������������������������������������������������������
������������������������������������������
AMETEK Nihon Drexelbrook AMETEK Singapore Pte. Ltd. AMETEK Precision Instruments Europe2 Chome • 12-7 Minami Gyotoku 10 Ang Mo Kio Street 65 Rudolf-Diesel-Strasse 16 Ichikawa City • Chiba 27201 Japan #05-12 Techpoint • 569059 Singapore D-40670 Meerbusch Germany Phone: 81-473-56-6513 Phone: 65-6484-2388 Phone: 49-2159-9136-0 Fax: 81-473-56-6535 Fax: 65-6481-6588 Fax: 49-2159-9136-39E-mail: nd@nihon-drexelbrook.co.jp E-mail: aspl@ametek.com.sg Web: www.ametek.de
U.S.A. Sales: 800-553-9092 • 24-Hour Service: 800-527-6297 • International Support: 215-674-1234 • Fax: 215-674-2731
DREXELBROOK205 Keith Valley Road
Horsham PA 19044 U.S.A.E-mail - drexelbrook.info@ametek.com
Web - www.drexelbrook.com ©2003, by AMETEK, Inc. All rights reserved. • Printed in the U.S.A. • 509-75-A • EDO# 3-04-244 • Issue #7
Universal III™ 509-75 SeriesSpecifications
509-75-X02 Universal IIITM
Smart Level Transmitter featuring700-2-27 Sensing Element
Typical Applications• Caustic• Fuel/Water Interface• Inorganic Acids• MEK/Water Interface
Do not use with:• Hydrofluoric Acid• Abrasive Slurries• Ferric Chloride
Process SpecificationsSensing Element
Pressure and Temperature Limits:1000 psi (69 BAR) @ 100°F (38°C) or500 psi (34.5 BAR) @ 300°F (149°C)
AgitationLess than two horsepower (greater ifsupported)
Process Wetted Parts:TFE, 316 SS and FEP (bonded)
Dimensions
Model Number of Structure
10¼(260)
.56 OD Rod(14)
FEP Insulation
Power In
5(127)
Dimensions in inches (mm)
¾-inch NPT (standard)
Flange (optional)
Insertion Length19 Feet maximum
(5.8 m)
For complete mounting and wiringdetails, request drawing419-2-74-CD.
7 = Remote9 = Integral
9 02
Sensing Element Condulet (For Remote Package Only)
Cable (For Remote Package Only)
Universal IIITM Smart Level Transmitter509 -0075 -
Sensing Element700 -0002-027- I _ _ _._
380- 0 -0120 25
Condulet Option0 = Standard Nema 4X1 = Nema 4X with Drexelcote
285-0001- 0 62Remote packages include242-0001-050 cable fitting installedin Condulet prior to shipping.
Cable Length025 = 25 feet (standard)010 = 10 feet035 = 35 feet050 = 50 feet075 = 75 feet100 = 100 feet
Insertion LengthInsertion Length in inches = 000.0(example 48 inches = 048.0)Maximum recommended insertion length = 228 inchesFor longer lengths, consult factory.
Probe MountingsBAO = ¾" NPT (standard)BBA = 1" 150# Raised Face (RF)
Carbon Steel (CS)BBB = 1" 150# RF 316SSBDA = 1½" 150# RF CSBDB = 1½" 150# RF 316SSBFA = 2" 150# RF CSBFB = 2" 150# RF 316SSBIA = 3" 150# RF CSBIB = 3" 150# RF 316SSBKA = 4" 150# RF CSBKB = 4" 150# RF 316SS
BCA = 1" 300# RF CSBCB = 1" 300# RF 316SSBEA = 1½" 300# RF CSBEB = 1½" 300# RF 316SSBGA = 2" 300# RF CSBGB = 2" 300# RF 316SSBJA = 3" 300# RF CSBJB = 3" 300# RF 316SSBLA = 4" 300# RF CSBLB = 4" 300# RF 316SS
Denotes default value
409 - 10X0 - XXX - 00 See Datasheet 509-75-A
BA0
509-75-X02-MNEDO# 3-04-244
7 = Remote9 = Integral
9 06
Sensing Element Condulet (For Remote Package Only)
Cable (For Remote Package Only)
Universal IIITM Smart Level Transmitter509 -0075 -
Sensing Element700 -0002-057- I _ _ _._
380- 0 -0120 25
Condulet Option0 = Standard Nema 4X1 = Nema 4X with Drexelcote
285-0001- 0 62Remote packages include242-0001-091 cable fitting installedin Condulet prior to shipping.
Cable Length025 = 25 feet (standard)
035 = 35 feet010 = 10 feet
050 = 50 feet075 = 75 feet100 = 100 feet
Insertion LengthInsertion Length in inches = 000.0(example 48 inches = 048.0)Maximum recommended insertion length = 240 inchesFor longer lengths, consult factory.
Probe MountingsBBO = 1" NPT (standard)BBA = 1" 150# Raised Face (RF)
Carbon Steel (CS)BBB = 1" 150# RF 316SSBDA = 1½" 150# RF CSBDB = 1½" 150# RF 316SSBFA = 2" 150# RF CSBFB = 2" 150# RF 316SSBIA = 3" 150# RF CSBIB = 3" 150# RF 316SSBKA = 4" 150# RF CSBKB = 4" 150# RF 316SS
BCA = 1" 300# RF CSBCB = 1" 300# RF 316SSBEA = 1½" 300# RF CSBEB = 1½" 300# RF 316SSBGA = 2" 300# RF CSBGB = 2" 300# RF 316SSBJA = 3" 300# RF CSBJB = 3" 300# RF 316SSBLA = 4" 300# RF CSBLB = 4" 300# RF 316SS
Denotes default value
409 - 10X0 - XXX - 00
BBO
509-75-X06 Universal III™Smart Level Transmitter featuring 700-2-57 Sensing Element
Typical Applications• Water• Acids• Alcohols
Process SpecificationsSensing Element
Pressure and Temperature Limits:1000 psi (69 BAR) @ 100°F (38°C) or500 psi (34.5 BAR) @ 250°F (121°C)
Agitation:Less than 1/3 horsepower
Process Wetted Parts:316 SS and "X" (bonded)"X" is a fluorocarbon-type insulation
Model Number of Structure
Dimensions
For complete mounting and wiringdetails, request drawing419-2-74-CD
10.23(260)
.84 OD Rod(21.3)
"X" Insulation
to Power In
5(127)
Dimensions in inches (mm)
1-inch NPT (standard)
Flange (optional) Insertion Length
20 Feet maximum(6.1m)
10.23(260)
.84 OD Rod(21.3)
"X" Insulation
to Power In
5(127)
Dimensions in inches (mm)
1-inch NPT (standard)
Flange (optional) Insertion Length
20 Feet maximum(6.1m)
Span2 inches (50) to 20 feet (6 m)
509-75-X06-MNEDO# 3-04-244
See Datasheet 509-75-A
509-75-X07 Universal IIITM
Smart Level Transmitter featuring700-2-24 Sensing Element
Typical Applications• Electrostatic Desalters
Heater TreatersSteam CondensatePVC Reactor Foam
•
Do not use with:• Hydrofluoric Acid• Styrene Monomer• Butydiene Monomer
Process SpecificationsSensing Element
Pressure and Temperature Limits1000 psi (69 BAR) @ 100°F (38°C) or500 psi (34.5 BAR) @ 450°F (232°C)
AgitationLess than two horsepower(greater if supported)
Process Wetted Parts316 SS and TFE (bonded)
Dimensions
Model Number of Structure
7 = Remote9 = Integral
9 07
Sensing Element Condulet (For Remote Package Only)
Cable (For Remote Package Only)
Universal IIITM Smart Level Transmitter509 -0075 -
Sensing Element700 -0002-024- I _ _ _._
380- 0 -0120 25
Condulet Option0 = Standard Nema 4X1 = Nema 4X with Drexelcote
285-0001- 0 62Remote packages include242-0001-091 cable fitting installedin Condulet prior to shipping.
Cable Length025 = 25 feet (standard)
050 = 50 feet075 = 75 feet100 = 100 feet
Insertion LengthInsertion Length in inches = 000.0(example 48 inches = 048.0)Maximum recommended insertion length = 168 inchesFor longer lengths, consult factory.
Probe MountingsBAO = ¾" NPT (standard)BBA = 1" 150# Raised Face (RF)
Carbon Steel (CS)BBB = 1" 150# RF 316SSBDA = 1½" 150# RF CSBDB = 1½" 150# RF 316SSBFA = 2" 150# RF CSBFB = 2" 150# RF 316SSBIA = 3" 150# RF CSBIB = 3" 150# RF 316SSBKA = 4" 150# RF CSBKB = 4" 150# RF 316SS
BCA = 1" 300# RF CSBCB = 1" 300# RF 316SSBEA = 1½" 300# RF CSBEB = 1½" 300# RF 316SSBGA = 2" 300# RF CSBGB = 2" 300# RF 316SSBJA = 3" 300# RF CSBJB = 3" 300# RF 316SSBLA = 4" 300# RF CSBLB = 4" 300# RF 316SS
Denotes default value
409 - 10X0 - XXX - 00
BA0
10.23(260)
¾-inch OD Rod(13.7)
TFE Insulation
to Power In
5(127)
Dimensions in inches (mm)
¾-inch NPT (standard)
Flange (optional)
Insertion Length14 Feet maximum
(4.3m)
6-inch (12-inch with flange)Cooling Extension
For complete mounting and wiringdetails, request drawing419-2-43-CD.
Span2 inches (50) to 14 feet (4 m)
509-75-X07-MNEDO# 3-04-244
035 = 35 feet010 = 10 feet
See Datasheet 509-75-A
509-75-X09 Universal III™Smart Level Transmitter featuring 700-1-22 Sensing Element
Typical Applications• Dilute Caustics (<10%)• Water• Inorganic Acids (Reagents)
Do not use with:• Hydrofluoric Acid• Sludge• Ferric Chloride
Process SpecificationsSensing Element
Pressure and Temperature Limits1000 psi (69 BAR) @ 100°F (38°C) or500 psi (34.5 BAR) @ 300°F (149°C)
AgitationLess than two horsepower (greaterif supported)
Process Wetted Parts316 SS and TFE (bonded)
Model Number of Structure
Dimensions
For complete mounting and wiringdetails, request drawing419-2-44-CD
10.23(260)
3/8 OD Rod(9.7)
TFE Insulation
to Power In
5(127)
Dimensions in inches (mm)
¾-inch NPT (standard)
Flange (optional) Insertion Length
20 Feet maximum(6.1m)
7 = Remote9 = Integral
9 09
Sensing Element Condulet (For Remote Package Only)
Cable (For Remote Package Only)
Universal IIITM Smart Level Transmitter509 -0075 -
Sensing Element700 -0001-022- I _ _ _._
380- 0 -0120 25
Condulet Option0 = Standard Nema 4X1 = Nema 4X with Drexelcote
285-0001- 0 62Remote packages include242-0001-091 cable fitting installedin Condulet prior to shipping.
Cable Length025 = 25 feet (standard)
050 = 50 feet075 = 75 feet100 = 100 feet
Insertion LengthInsertion Length in inches = 000.0(example 48 inches = 048.0)Maximum recommended insertion length = 240 inchesFor longer lengths, consult factory.
Probe MountingsBAO = ¾" NPT (standard)BBA = 1" 150# Raised Face (RF)
Carbon Steel (CS)BBB = 1" 150# RF 316SSBDA = 1½" 150# RF CSBDB = 1½" 150# RF 316SSBFA = 2" 150# RF CSBFB = 2" 150# RF 316SSBIA = 3" 150# RF CSBIB = 3" 150# RF 316SSBKA = 4" 150# RF CSBKB = 4" 150# RF 316SS
BCA = 1" 300# RF CSBCB = 1" 300# RF 316SSBEA = 1½" 300# RF CSBEB = 1½" 300# RF 316SSBGA = 2" 300# RF CSBGB = 2" 300# RF 316SSBJA = 3" 300# RF CSBJB = 3" 300# RF 316SSBLA = 4" 300# RF CSBLB = 4" 300# RF 316SS
Denotes default value
409 - 10X0 - XXX - 00
BAO
509-75-X09-MNEDO# 3-04-244
Span2 inches (50mm) to 20 feet (6 m)
035 = 35 feet010 = 10 feet
See Datasheet 509-75-A
509-75-X13 Universal III™Smart Level Transmitter featuring700-5-18 Sensing Element
Typical Applications• Mineral Slurries• Paper Pulp• Oil/Water Interface
Do not use with:• Caustic (over 10%)• Sulfuric Acid (Over 20%)• Nitric Acid (over 30%)• Acetone• MEK and other Ketones
Process SpecificationsSensing Element
Pressure and Temperature Limits100°F @ 1000 psi 38°C @ 69 BAR250°F @ 500 psi 121°C @ 34.5 BAR
AgitationUp to 30 horsepower (when anchored)
Process Wetted PartsTFE, 316 SS, and Kynar (PVDF)insulation
Model Number of Structure
Dimensions
7 = Remote9 = Integral
9 13
Sensing Element Condulet (For Remote Package Only)
Cable (For Remote Package Only)
Universal IIITM Smart Level Transmitter509 -0075 -
Sensing Element700 -0005-018 - F _ _ _._
380- 0 -0120 25
Condulet Option0 = Standard Nema 4X1 = Nema 4X with Drexelcote
285-0001- 0 64Remote packages include242-0001-091 cable fitting installedin Condulet prior to shipping.
Cable Length025 = 25 feet (standard)
050 = 50 feet075 = 75 feet100 = 100 feet
Insertion LengthInsertion Length in feet = 000.0(example 48 feet = 048.0)Maximum recommended insertion length = 100 feetFor longer lengths, consult factory.
Probe MountingsBAO = ¾" NPT (standard)BBA = 1" 150# Raised Face (RF)
Carbon Steel (CS)BBB = 1" 150# RF 316SSBDA = 1½" 150# RF CSBDB = 1½" 150# RF 316SSBFA = 2" 150# RF CSBFB = 2" 150# RF 316SSBIA = 3" 150# RF CSBIB = 3" 150# RF 316SSBKA = 4" 150# RF CSBKB = 4" 150# RF 316SS
BCA = 1" 300# RF CSBCB = 1" 300# RF 316SSBEA = 1½" 300# RF CSBEB = 1½" 300# RF 316SSBGA = 2" 300# RF CSBGB = 2" 300# RF 316SSBJA = 3" 300# RF CSBJB = 3" 300# RF 316SSBLA = 4" 300# RF CSBLB = 4" 300# RF 316SS
Denotes default value
409 - 10X0 - XXX - 00
BA0
For complete mounting and wiringdetails, request drawing419-2-45-CD.
10.23(260)
5(127)
to Power In
5/16 OD(7.9)
Flexible CablePVDF insulation
¾-10 UNC-2E2 5/8
Insertion Length
100 feet (30 m) maximum
¾-inch NPTFlange
(optional)
Seal Fitting
¾-inch NPT
½-20 Thread
Flexible Bottom Anchor
7/8 OD
2¼ (57)
5 7/8 (149)
Dimensions in inches (mm)
Span:2 inches (50mm) to 100 feet (30 m)
509-75-X13-MNEDO# 3-04-244
035 = 35 feet010 = 10 feet
See Datasheet 509-75-A
7 = Remote9 = Integral
9 17
Sensing Element Condulet (For Remote Package Only)
Cable (For Remote Package Only)
Universal IIITM Smart Level Transmitter509 -0075 -
Sensing Element700 -0001-344 - I _ _ _._
380- 0 -0120 25
Condulet Option0 = Standard Nema 4X1 = Nema 4X with Drexelcote
285-0001- 0 62Remote packages include242-0001-091 cable fitting installedin Condulet prior to shipping.
Cable Length025 = 25 feet (standard)
050 = 50 feet075 = 75 feet100 = 100 feet
Insertion LengthInsertion Length in inches = 000.0(example 48 inches = 048.0)Maximum recommended insertion length = 240 InchesFor longer lengths, consult factory.
Probe MountingsBBG = 1" 150# Raised Face (RF)
Carbon Steel (CS)BBH = 1" 150# RF 316SSBDG = 1½" 150# RF CSBDH = 1½" 150# RF 316SSBFG = 2" 150# RF CSBFH = 2" 150# RF 316SSBIG = 3" 150# RF CSBIH = 3" 150# RF 316SSBKG = 4" 150# RF CSBKH = 4" 150# RF 316SS
BCG = 1" 300# RF CSBCH = 1" 300# RF 316SSBEG = 1½" 300# RF CSBEH = 1½" 300# RF 316SSBGC = 2" 300# RF CSBGH = 2" 300# RF 316SSBJG = 3" 300# RF CSBJH = 3" 300# RF 316SSBLG = 4" 300# RF CSBLH = 4" 300# RF 316SS
Denotes default value
409 - 10X0 - XXX - 00
_ _ _
509-75-X17 Universal III™Smart Level Transmitter featuring 700-1-344 Sensing Element
Typical Applications• Hazardous Liquids• Osmotic Liquids• Corrosive liquids
Feerwater Heaters
Process SpecificationsSensing Element
Pressure and Temperature Limits1000 psi (69 BAR) @ 100°F (38°C) or500 psi (34.5 BAR) @ 350°F (177°C)
AgitationLess than 1/3 horsepower
Process Wetted PartsAll PFA (bonded)
Model Number of Structure
Dimensions
5(127)
10.23(260)
PFASeal-Tyte
Flange Face
3/8 (9.7) OD RodPFA Insulation
Insertion Length20 Feet maximum
(6.1m)
Flange Mountingstandard
to Power In
Dimensions in inches (mm)
5(127)
10.23(260)
PFASeal-Tyte
3/8 (9.7) OD RodPFA Insulation
Insertion Length20 Feet maximum
(6.1m)
RF
to Power In
Dimensions in inches (mm)
For complete mounting and wiringdetails, request drawing419-2-24-CD
Span2 inches (50) to 20 feet (6 m)
509-75-X17-MNEDO# 3-04-244
035 = 35 feet010 = 10 feet
See Datasheet 509-75-A
10.23(260)
5(127)
Power In
TFE Sheath
.093 OD(2.36)
Flexible Cable
PFA Insulation
TFE Bottom Termination
½-20 UNF
TFE Weight (optional)
¾(19)
6(152)
1½(38)
Insertion Length
100 feet (30 m) maximum
¾-inch NPTFlange
(optional)
Dimensions in inches (mm)
509-75-X25 Universal III™Smart Level Transmitter featuring700-5-54 Sensing Element
Typical Applications• Water• Liquors• Caustics
Process SpecificationsSensing Element
Pressure and Temperature Limits1000 psi (69 BAR) @ 100°F (38°C) or500 psi (34.5 BAR) @ 350°F (177°C)
AgitationLess than 1/3 horsepower
Process Wetted Parts316 SS, TFE, and PFA
Model Number of Structure
Dimensions
For complete mounting and wiringdetails, request drawing419-2-24-CD
Span2 inches (50) to 100 feet (30 m)
7 = Remote9 = Integral
9 25
Sensing Element Condulet (For Remote Package Only)
Cable (For Remote Package Only)
Universal IIITM Smart Level Transmitter509 -0075 -
Sensing Element700 -0005-054- F _ _ _._
380- 0 -0120 25
Condulet Option0 = Standard Nema 4X1 = Nema 4X with Drexelcote
285-0001- 0 62Remote packages include242-0001-091 cable fitting installedin Condulet prior to shipping.
Cable Length025 = 25 feet (standard)
050 = 50 feet075 = 75 feet100 = 100 feet
Insertion LengthInsertion Length in feet = 000.0(example 48 feet = 048.0)Maximum recommended insertion length = 100 feetFor longer lengths, consult factory.
Probe MountingsBAO = ¾" NPT (standard)BBA = 1" 150# Raised Face (RF)
Carbon Steel (CS)BBB = 1" 150# RF 316SSBDA = 1½" 150# RF CSBDB = 1½" 150# RF 316SSBFA = 2" 150# RF CSBFB = 2" 150# RF 316SSBIA = 3" 150# RF CSBIB = 3" 150# RF 316SSBKA = 4" 150# RF CSBKB = 4" 150# RF 316SS
BCA = 1" 300# RF CSBCB = 1" 300# RF 316SSBEA = 1½" 300# RF CSBEB = 1½" 300# RF 316SSBGA = 2" 300# RF CSBGB = 2" 300# RF 316SSBJA = 3" 300# RF CSBJB = 3" 300# RF 316SSBLA = 4" 300# RF CSBLB = 4" 300# RF 316SS
Denotes default value
409 - 10X0 - XXX - 00
BA0
509-75-X25-MNEDO# 3-04-244
035 = 35 feet010 = 10 feet
See Datasheet 509-75-A
509-75-X31 Universal III™Smart Level Transmitter featuring700-1-52 Sensing ElementThis instrument includes an integral ground reference rodfor non-metallic tanks.
Typical Applications• Diluted Caustics (less than 10%)• Acids• Clean Water for: Cooling
Drinking Fire
Dilution
Do not use with:• Hydrofluoric Acid• Styrene Monomer• Butadiene (more than 30% concentration)
Process SpecificationsSensing Element
Pressure and Temperature Limits1000 psi (69 BAR) @ 100°F (38°C) or500 psi (34.5 BAR) @ 300°F (149°C)
AgitationLess than 1/2 horsepower
Process Wetted PartsTFE and Hastelloy C
Model Number of Structure
For complete mounting and wiringdetails, request drawing419-2-24-CD
Dimensions
7 = Remote9 = Integral
9 31
Sensing Element Condulet (For Remote Package Only)
Cable (For Remote Package Only)
Universal IIITM Smart Level Transmitter509 -0075 -
Sensing Element700 -0001-052 - I _ _ _._
380- 0 -0120 25
Condulet Option0 = Standard Nema 4X1 = Nema 4X with Drexelcote
285-0001- 0 62Remote packages include242-0001-091 cable fitting installedin Condulet prior to shipping.
Cable Length025 = 25 feet (standard)
050 = 50 feet075 = 75 feet100 = 100 feet
Insertion LengthInsertion Length in inches = 000.0(example 48 inches = 048.0)Maximum recommended insertion length = 240 inchesFor longer lengths, consult factory.
Denotes default value
409 - 10X0 - XXX - 00
BFC
5(127)
1 5/8(41.3)
Insertion Length20 Feet maximum
(6.1m)
3/8 OD Rod(9.7)
TFE Insulation
3/8 OD Rod(9.7)
TFE Insulation
TFEFlange Face
Standard
to Power In
12(305)
¼ OD(6.4)
Hastelloy CGround Rod
Dimensions in inches (mm)
Span2 inches (50) to 20 feet (6 m)
509-75-X31-MNEDO# 3-04-244
035 = 35 feet010 = 10 feet
See Datasheet 509-75-A
509-75-X32 Universal III™Smart Level Transmitter featuring700-2-62 Sensing ElementThis instrument includes an integral ground reference rodfor non-metallic tanks.
Typical Applications• Aqueous Slurries• Salt Solutions• Inorganic Acids• Oil/Water Interface
Do not use with:• Caustic• Sulfuric Acid (over 20%)• Nitric Acid (over 30%)• Acetone• MEK and other Ketones
Process SpecificationsSensing Element
Pressure and Temperature Limits1000 psi (69 BAR) @ 100°F (38°C) or500 psi (34.5 BAR) @ 250°F (121°C)
AgitationLess than 1/2 horsepower
Process Wetted PartsTFE, Hastelloy C, and Kynar (PVDF)insulation
Model Number of Structure
For complete mounting and wiringdetails, request drawing419-2-24-CD
7 = Remote9 = Integral
9 32
Sensing Element Condulet (For Remote Package Only)
Cable (For Remote Package Only)
Universal IIITM Smart Level Transmitter509 -0075 -
Sensing Element700 -0002-062 - I _ _ _._
380- 0 -0120 25
Condulet Option0 = Standard Nema 4X1 = Nema 4X with Drexelcote
285-0001- 0 62Remote packages include242-0001-091 cable fitting installedin Condulet prior to shipping.
Cable Length025 = 25 feet (standard)
050 = 50 feet075 = 75 feet100 = 100 feet
Insertion LengthInsertion Length in inches = 000.0(example 48 inches = 048.0)Maximum recommended insertion length = 240 inchesFor longer lengths, consult factory.
Denotes default value
409 - 10X0 - XXX - 00
BFC
5(127)
1 5/8(41.3)
Insertion Length20 Feet maximum
(6.1m)
3/8 OD Rod(9.7)
TFE Insulation
TFEFlange Face
Standard
to Power In
12(305)
¼ OD(6.4)
Hastelloy CGround Rod
0.84 OD Rod(21.3)
PVDF Insulation
Dimensions in inches (mm)
Dimensions
Span:2 inches (50) to 20 feet (6 m)
509-75-X32-MNEDO# 3-04-244
035 = 35 feet010 = 10 feet
See Datasheet 509-75-A
509-75-938 Checkwell™Smart Water Level Monitor featuring700-5-35 Sensing Element
Typical Applications• Production Wells• Monitoring Wells• Observation Wells• Remediation Wells• Artesian Wells• Level or Drawdown
For complete mounting and wiringdetails, request drawing700-5-35-CD
Process SpecificationsSensing Element
Pressure and Temperature Limits500 psi (34 BAR) @ 300°F (148°C)
Process Wetted PartsPVC, 316 SS and PFA Insulation
Model Number of Structure
¾-inch NPT
10 inchesmaximum
(254)
FlexiblePVC Boot
PFA Spacer.687 (17.44) OD for¾-inch (19.05) ID or
larger space
Dimensions in inches (mm)
Insertion Length
InactiveWeight
Assembly26 (660)standard50 (1270)optional
¾-inch NPTFlange mounting
optional
2¾(69)
Dimensions
7 = Remote9 = Integral
9 38
Sensing Element Condulet (For Remote Package Only)
Cable (For Remote Package Only)
Universal IIITM Smart Checkwell Water Level Monitor
509 -0075 -
Sensing Element700 -0005-035- F _ _ _._
380- 0 -0120 25
Condulet Option0 = Standard Nema 4X1 = Nema 4X with Drexelcote
285-0001- 0 62Remote packages include242-0001-091 cable fitting installedin Condulet prior to shipping.
Cable Length025 = 25 feet (standard)
050 = 50 feet075 = 75 feet100 = 100 feet
Insertion LengthInsertion Length in feet = 000.0(example 48 feet = 048.0)Maximum recommended insertion length = 800 feet.For longer lengths, consult factory.
Probe MountingsBAO = ¾" NPT (standard)BBA = 1" 150# Raised Face (RF)
Carbon Steel (CS)BBB = 1" 150# RF 316SSBDA = 1½" 150# RF CSBDB = 1½" 150# RF 316SSBFA = 2" 150# RF CSBFB = 2" 150# RF 316SSBIA = 3" 150# RF CSBIB = 3" 150# RF 316SSBKA = 4" 150# RF CSBKB = 4" 150# RF 316SS
BCA = 1" 300# RF CSBCB = 1" 300# RF 316SSBEA = 1½" 300# RF CSBEB = 1½" 300# RF 316SSBGA = 2" 300# RF CSBGB = 2" 300# RF 316SSBJA = 3" 300# RF CSBJB = 3" 300# RF 316SSBLA = 4" 300# RF CSBLB = 4" 300# RF 316SS
Denotes default value
409 - 10X0 - XXX - 00
BAO
Span2 inches (50) to 999 feet (305 m)
509-75-938-MNEDO# 3-04-244
035 = 35 feet010 = 10 feet
See Datasheet 509-75-A
10.23(260)
3/8 OD Rod(9.7)
TFE Insulation
to Power In
5(127)
Dimensions in inches (mm)
1½-inch NPT (standard)
Flange (optional)
Insertion Length
20 Feet maximum
(6.1m)
1.66 OD Concentric Shield
(42)
509-77-X16 Universal IIITM
Smart Level Transmitterfeaturing 700-1-26 Sensing ElementTransmitter can be precalibrated and its output is linearregardless of tank geometry.
Typical Applications•Diesel / #2 Fuel•Organic Acids•Food Oils
Do not use with:• Hydrofluoric Acid• Slurries• Styrene Monomer
Butadiene
Process SpecificationsSensing Element
Pressure and Temperature Limits1000 psi (69 BAR) @ 100°F (38°C) or500 psi (34.5 BAR) @ 300°F (149°C)
AgitationLess than four horsepower(greater if supported)
Process Wetted Parts316 SS and TFE (bonded) Insulation
Dimensions
Model Number of Structure
For complete mounting and wiringdetails, request drawing419-2-63-CD.
Span24 inches (610m) to 20 feet (6 m)
7 = Remote9 = Integral
9 16
Sensing Element Condulet (For Remote Package Only)
Cable (For Remote Package Only)
Universal IIITM Smart Level Transmitter509 -0077 -
Sensing Element700 -0001-026 I _ _ _._ BCO
380- 0 -012025
Condulet Option0 = Standard Nema 4X1 = Nema 4X with Drexelcote
285-0001- 0 62Remote packages include242-0001-091 cable fitting installedin Condulet prior to shipping.
Cable Length025 = 25 feet (standard)
050 = 50 feet075 = 75 feet100 = 100 feet
Insertion LengthInsertion Length in inches = 000.0(example 48 inches = 048.0)Maximum recommended insertion length = 240 inchesFor longer lengths, consult factory.
ANSI Probe MountingsBCO = 1½" NPT (standard) 316SSACO = 1½" NPT Carbon Steel (CS)BFB = 2" 150# RF 316SSAFB = 2" 150# RF CSBGB = 2" 300# RF 316SSAGB = 2" 300# RF CS
BIB = 3" 150# RF 316SSAIB = 3" 150# RF CSBJB = 3" 300# RF 316SSAJB = 3" 300# RF CSBKB = 4" 150# RF 316SSAKB = 4" 150# RF CSBLB = 4" 300# RF 316SSALB = 4" 300# RF CS
Denotes default value
409 - 1X00 - XXX - 0X
509-77-X16-MNEDO# 3-04-244
035 = 35 feet010 = 10 feet
See Datasheet 509-75-A
InsertionLength
3(76)
2(50)
1(25)
7/8(22)
1" NPT
Bare 316SSFlexible Cable
Weight
ActiveInsertionLength
3/16(5)
Condulet
2¾(70)
maximum
Center Wire
ShieldWire
10.25(260)
509-77-X20 Universal IIITM
Smart Level Transmitterfeaturing 700-205-15 Sensing Element
Typical Applications• Asphalt• Molten Sulfer• #6 Fuel Oil• Ink
Do not use with• Conductive materials• Materials corrosive to 316SS
Span24 inches (610) to 200 feet (61 m)
7 = Remote9 = Integral
9 20
Sensing Element Condulet (For Remote Package Only)
Cable (For Remote Package Only)
Universal IIITM Smart Level Transmitter509 -0077 -
Sensing Element700 -0205 - 15 - F _ _ _._
380- 0 -0120 25
Condulet Option0 = Standard Nema 4X1 = Nema 4X with Drexelcote
285-0001- 0 64Remote packages include242-0001-091 cable fitting installedin Condulet prior to shipping.
Cable Length025 = 25 feet (standard)
050 = 50 feet075 = 75 feet100 = 100 feet
Insertion LengthInsertion Length in feet = 000.0(example 48 feet = 048.0)Maximum recommended insertion length = 200 feetFor longer lengths, consult factory.
Probe MountingsBBO = 1" NPT (standard)BBA = 1" 150# Raised Face (RF)
Carbon Steel (CS)BBB = 1" 150# RF 316SSBDA = 1½" 150# RF CSBDB = 1½" 150# RF 316SSBFA = 2" 150# RF CSBFB = 2" 150# RF 316SSBIA = 3" 150# RF CSBIB = 3" 150# RF 316SSBKA = 4" 150# RF CSBKB = 4" 150# RF 316SS
BCA = 1" 300# RF CSBCB = 1" 300# RF 316SSBEA = 1½" 300# RF CSBEB = 1½" 300# RF 316SSBGA = 2" 300# RF CSBGB = 2" 300# RF 316SSBJA = 3" 300# RF CSBJB = 3" 300# RF 316SSBLA = 4" 300# RF CSBLB = 4" 300# RF 316SS
Denotes default value
409 - 10X0 - XXX - 00
BB00 = Remote1 = Integral
X
For complete mounting and wiringdetails, request drawing419-2-64-CD.
Process SpecificationsSensing Element
Pressure and Temperature Limits0 psi (0 BAR) @ 450°F (232°C)
AgitationLess than 1/3 horsepower(greater if anchored)
Process Wetted Parts316 SS and TFE
Model Number of Structure
Dimensions
509-77-X20-MNEDO# 3-04-244
035 = 35 feet010 = 10 feet
See Datasheet 509-75-A