TYPICAL AUDITION PLANK SECTION DETAIL - ASI Architectural · sprinkler head detail - plan view 2 1...

Post on 20-Jul-2020

4 views 0 download

Transcript of TYPICAL AUDITION PLANK SECTION DETAIL - ASI Architectural · sprinkler head detail - plan view 2 1...

3/4"

SUSPENSION (BY

OTHER)

15

16

" HEAVY DUTY

T-GRID (BY OTHER)

T&G GRID CLIPS

* ACOUSTICAL BACKER RECOMMENDED

T&G GRID CLIP FOR

15

16

" HD T-GRID ONLY

6" = 1'-0"

1

TYPICAL AUDITION PLANK SECTION DETAIL

1' = 1'-0"

2

T&G GRID CLIP

1' = 1'-0"

3

T&G DIRECT ATTACH CLIP

LAST REVISED: DRAWN BY:SCALE: AS NOTED

DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS

REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018

123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BMH4/23/2018

AUDITION T&G CEILING SYSTEM - SECTION & CLIP OPTIONS

SHEET NUMBER

1

TONGUE SIDE

GROOVE SIDE

PERFORATIONS (DO

NOT GO THROUGH TO

FRONT SIDE OF PANEL)

PLANK FACE

TONGUE SIDE

GROOVE SIDE

PLANK FACE

LAST REVISED: DRAWN BY:SCALE: AS NOTED

DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS

REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018

123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BMH4/23/2018

AUDITION T&G - PLANK OPTIONS AND DETAILS

3" = 1'-0"

1

BACK OF PLANK ISOMETRIC

3" = 1'-0"

2

FRONT OF PLANK ISOMETRIC

16MM SPACING BETWEEN KERFS SHOWN. 8MM, 24MM, AND 32MM OPTIONS AVAILABLE

SHEET NUMBER

2

START PATTERN

FROM ROOM CENTER

15

16

" H.D. T-BAR GRID

MAINS BY OTHER

(2'-0" O.C. TYP)

JOINTS TO LAND

ON T-GRID

JOINTS TO LAND

ON T-GRID

START PATTERN

FROM ROOM CENTER

15

16

" H.D. T-BAR GRID

MAINS BY OTHER

(2'-0" O.C. TYP)

1/2" = 1'-0"

1

TYPICAL PATTERN RCP (OPTION 1 - CENTERED ON PLANK)

1/2" = 1'-0"

2

TYPICAL PATTERN RCP (OPTION 2 - CENTERED ON REVEAL)

LAST REVISED: DRAWN BY:SCALE: AS NOTED

DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS

REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018

123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BMH4/23/2018

AUDITION T&G CEILING SYSTEM - FRAMING

SHEET NUMBER

3

JOINT CENTERED

ON GRID

T&G GRID CLIP

15

16

" HEAVY DUTY

T-GRID (BY OTHER)

TRIM (AS SPECIFIED)

AUDITION PLANK

1

4

" X 1

1

4

" DOWEL

15

16

" HEAVY DUTY

T-GRID (BY OTHER)

TRIM (AS SPECIFIED)

ACOUSTICAL BACKER

RECOMMENDED

1 1/2" = 1'-0"

1

ISOMETRIC VIEW - TYP.

LAST REVISED: DRAWN BY:SCALE: AS NOTED

DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS

REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018

123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BMH4/23/2018

AUDITION T&G CEILING SYSTEM - ISOMETRIC

SHEET NUMBER

4

FIELD CUT MITERS TYP.

TRIM

AUDITION PLANK

15

16

" HEAVY DUTY

T-GRID (BY OTHER)

T&G GRID CLIP

8" MAXIMUM

CANTILEVER

4" T

YP

6" M

AX

HANGER

(BY OTHER)

15

16

" HEAVY DUTY

T-GRID (BY OTHER)

T&G GRID CLIP

* ACOUSTICAL BACKER RECOMMENDED

4" T

YP

6" M

AX

T-GRID (BY OTHER)

SUSPENSION

(BY OTHER)

15

16

" HEAVY

DUTY T-GRID

(BY OTHER)

FIELD CUT

T&G GRID CLIP

1" = 1'-0"

1

CLOUD VERTICAL TRIM PLAN

3" = 1'-0"

2

TRIM @ EDGE - FRONT SECTION

3" = 1'-0"

3

TRIM @ EDGE - SIDE SECTION

2

3

LAST REVISED: DRAWN BY:SCALE: AS NOTED

DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS

REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018

123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BMH4/23/2018

AUDITION T&G CEILING SYSTEM - TRIM CONDITIONS

SHEET NUMBER

5

8" MAXIMUM

CANTILEVER

SUSPENSION

(BY OTHER)

15

16

" HEAVY DUTY

T-GRID (BY OTHER)

FIELD CUT TO ALLOW

FOR

1

2

" MIN REVEAL

FOR EXPANSION AND

CONTRACTION

T&G GRID CLIP

* ACOUSTICAL BACKER RECOMMENDED

SUSPENSION

(BY OTHER)

15

16

" HEAVY DUTY

T-GRID (BY OTHER)

T&G GRID CLIP

FIELD CUT TO ALLOW

FOR

1

2

" MIN REVEAL

FOR EXPANSION AND

CONTRACTION

8" MAXIMUM

CANTILEVER

SUSPENSION

(BY OTHER)

WALL ANGLE

(BY OTHER)

15

16

" HEAVY DUTY

T-GRID (BY OTHER)

FIELD CUT TO ALLOW

FOR

1

2

" MIN REVEAL

FOR EXPANSION AND

CONTRACTION

T&G GRID CLIP

* ACOUSTICAL BACKER RECOMMENDEDSUSPENSION

(BY OTHER)

WALL ANGLE

(BY OTHER)

FIELD CUT TO ALLOW

FOR

1

2

" MIN REVEAL

FOR EXPANSION AND

CONTRACTION

15

16

" HEAVY DUTY

T-GRID (BY OTHER)

T&G GRID CLIP

3" = 1'-0"

1

FLOATING - SIDE SECTION

3" = 1'-0"

2

FLOATING - FRONT SECTION

3" = 1'-0"

3

WALL ANGLE ABOVE - SIDE SECTION

3" = 1'-0"

4

WALL ANGLE ABOVE - FRONT SECTION

LAST REVISED: DRAWN BY:SCALE: AS NOTED

DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS

REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018

123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BMH4/23/2018

AUDITION T&G CEILING SYSTEM - EDGE CONDITIONS @ WALL

SHEET NUMBER

6

8" MAXIMUM

CANTILEVER

SUSPENSION

(BY OTHER)

WALL ANGLE

(BY OTHER)

15

16

" HEAVY DUTY

T-GRID (BY OTHER)

FIELD CUT TO ALLOW

FOR

1

2

" MIN REVEAL

FOR EXPANSION AND

CONTRACTION

T&G GRID CLIP

* ACOUSTICAL BACKER RECOMMENDED

SUSPENSION

(BY OTHER)

WALL ANGLE

(BY OTHER)

FIELD CUT TO ALLOW

FOR

1

2

" MIN REVEAL

FOR EXPANSION AND

CONTRACTION

15

16

" HEAVY DUTY

T-GRID (BY OTHER)

T&G GRID CLIP

3" = 1'-0"

1

WALL ANGLE BELOW - SIDE SECTION

3" = 1'-0"

2

WALL ANGLE BELOW - FRONT SECTION

LAST REVISED: DRAWN BY:SCALE: AS NOTED

DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS

REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018

123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BMH4/23/2018

AUDITION T&G CEILING SYSTEM - EDGE CONDITIONS @ WALL

SHEET NUMBER

7

AUDITION PLANK

INDEPENDENTLY SUPPORTED

SPRINKLER: FIELD CUT

PENETRATION

IF PENETRATION EXCEEDS

2

3

BOARD WIDTH, SUPPORT

BRACKETS ARE NEEDED

(BY OTHER)

15

16

" HEAVY DUTY

T-GRID (BY OTHER)

T&G GRID CLIP

INDEPENDENTLY SUPPORTED

SPRINKLER: FIELD CUT

PENETRATION

IF PENETRATION EXCEEDS

2

3

BOARD WIDTH, SUPPORT

BRACKETS ARE NEEDED

(BY OTHER)

15

16

" HEAVY DUTY

T-GRID (BY OTHER)

T&G GRID CLIP

SUPPORT BRACKET

FASTENED W/ SCREWS

TO PLANKS (BY OTHER)

PIPE HANGER ANCHORED

TO BUILDING STRUCTURE

(BY OTHER)

SUSPENSION (BY OTHER)

1 1/2" = 1'-0"

1

SPRINKLER HEAD DETAIL - PLAN VIEW

1 1/2" = 1'-0"

2

SPRINKLER HEAD DETAIL - SECTION VIEW

2

LAST REVISED: DRAWN BY:SCALE: AS NOTED

DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS

REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018

123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BMH4/23/2018

AUDITION T&G CEILING SYSTEM - SPRINKLER HEAD DETAIL

SHEET NUMBER

8

AUDITION PLANK

INDEPENDENTLY SUPPORTED

CAN LIGHT: FIELD CUT

PENETRATION

IF PENETRATION EXCEEDS

2

3

BOARD WIDTH, SUPPORT

BRACKETS ARE NEEDED

(BY OTHER)

15

16

" HEAVY DUTY

T-GRID (BY OTHER)

T&G GRID CLIP

INDEPENDENTLY SUPPORTED

CAN LIGHT: FIELD CUT

PENETRATION

TRIM RING (BY OTHER)

15

16

" HEAVY DUTY

T-GRID (BY OTHER)

T&G GRID CLIP

1 1/2" = 1'-0"

1

CAN LIGHT DETAIL - PLAN VIEW

1 1/2" = 1'-0"

2

CAN LIGHT DETAIL - SECTION VIEW

2

LAST REVISED: DRAWN BY:SCALE: AS NOTED

DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS

REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018

123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BMH4/23/2018

AUDITION T&G CEILING SYSTEM - CAN LIGHT DETAIL

SHEET NUMBER

9

AUDITION PLANK

INDEPENDENTLY SUPPORTED

PENDANT LIGHT: FIELD CUT

PENETRATION

IF PENETRATION EXCEEDS

2

3

BOARD WIDTH, SUPPORT

BRACKETS ARE NEEDED

(BY OTHER)

15

16

" HEAVY DUTY

T-GRID (BY OTHER)

T&G GRID CLIP

INDEPENDENTLY SUPPORTED

PENDANT LIGHT: FIELD CUT

PENETRATION

15

16

" HEAVY DUTY

T-GRID (BY OTHER)

TRIM PLATE

(BY OTHER)

T&G GRID CLIP

SUSPENSION

(BY OTHER)

1 1/2" = 1'-0"

1

PENDANT LIGHT DETAIL - PLAN VIEW

1 1/2" = 1'-0"

2

PENDANT LIGHT DETAIL - SECTION DETAIL

2

LAST REVISED: DRAWN BY:SCALE: AS NOTED

DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS

REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018

123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BMH4/23/2018

AUDITION T&G CEILING SYSTEM - PENDANT LIGHT DETAIL

SHEET NUMBER

10

AUDITION PLANK

INDEPENDENTLY SUPPORTED

SPEAKER: FIELD CUT

PENETRATION

IF PENETRATION EXCEEDS

2

3

BOARD WIDTH, SUPPORT

BRACKETS ARE NEEDED

(BY OTHER)

15

16

" HEAVY DUTY

T-GRID (BY OTHER)

T&G GRID CLIP

INDEPENDENTLY SUPPORTED

SPEAKER: FIELD CUT

PENETRATION

15

16

" HEAVY DUTY

T-GRID (BY OTHER)

TRIM PLATE

(BY OTHER)

T&G GRID CLIP

SUSPENSION

(BY OTHER)

1 1/2" = 1'-0"

1

RECESSED SPEAKER DETAIL - PLAN VIEW

1 1/2" = 1'-0"

2

RECESSED SPEAKER DETAIL - SECTION VIEW

2

LAST REVISED: DRAWN BY:SCALE: AS NOTED

DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS

REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018

123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BMH4/23/2018

AUDITION T&G CEILING SYSTEM - RECESSED SPEAKER DETAIL

SHEET NUMBER

11

AUDITION PLANK

INDEPENDENTLY SUPPORTED

AUDITION LIGHT: FIELD CUT

PENETRATION

BRACKETS REQ'D

(BY OTHER)

15

16

" HEAVY DUTY

T-GRID (BY OTHER)

T&G GRID CLIP

T&G GRID CLIP

INDEPENDENTLY SUPPORTED

AUDITION LIGHT: FIELD CUT

PENETRATION

15

16

" HEAVY DUTY

T-GRID (BY OTHER)

TRIM PLATE

(BY OTHER)

SUSPENSION

(BY OTHER)

1" = 1'-0"

1

LINEAR LIGHT DETAIL - PLAN VIEW

1 1/2" = 1'-0"

2

LINEAR LIGHT DETAIL - SECTION VIEW

2

LAST REVISED: DRAWN BY:SCALE: AS NOTED

DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS

REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018

123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BMH4/23/2018

AUDITION T&G CEILING SYSTEM - LINEAR LIGHT DETAIL

SHEET NUMBER

12

AUDITION PLANK

IF PENETRATION EXCEEDS

2

3

BOARD WIDTH,

SUPPORT BRACKETS ARE

NEEDED (BY OTHER)

15

16

" HEAVY DUTY

T-GRID (BY OTHER)

T&G GRID CLIP

INDEPENDENTLY

SUPPORTED

DIFFUSER: FIELD CUT

PENETRATION

INDEPENDENTLY

SUPPORTED

DUCTWORK

(BY OTHER)

15

16

" HEAVY DUTY

T-GRID (BY OTHER)

T&G GRID CLIP

INDEPENDENTLY SUPPORTED

DIFFUSER: FIELD CUT

PENETRATION

1 1/2" = 1'-0"

1

LINEAR DIFFUSER DETAIL - PLAN VIEW

1 1/2" = 1'-0"

2

LINEAR DIFFUSER DETAIL - SECTION VIEW

2

LAST REVISED: DRAWN BY:SCALE: AS NOTED

DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS

REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018

123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BMH4/23/2018

AUDITION T&G CEILING SYSTEM - DIFFUSER DETAIL

SHEET NUMBER

13

SCRAP

15

16

" HD

T-GRID BACKER

RAILS TO BE BACK

SCREWED IN FIELD

ACCESS PANEL

SEAM (FIELD CUT)

A

C

C

E

S

S

P

A

N

E

L

T&G GRID CLIP

RIP TONGUE IN FIELD

RIP TONGUE IN FIELD

T&G GRID CLIP

SCREWED TO

BACKER

RIP TONGUE

IN FIELD

FIXED PLANK

(BACKSCREWED

TO CEILING GRID)

BACKER RAILS

(BY OTHER)

FIXED PLANK

(BACKSCREWED

TO CEILING GRID)

RIP TONGUE

IN FIELD

1 1/2" = 1'-0"

1

ACCESS PANEL DETAIL

3" = 1'-0"

2

ACCESS PANEL SECTION

2

LAST REVISED: DRAWN BY:SCALE: AS NOTED

DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS

REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018

123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BMH4/23/2018

AUDITION T&G CEILING SYSTEM - ACCESS PANEL

SHEET NUMBER

14

TYP. WALL ASSEMBLY

(BY OTHER)

T&G DIRECT ATTACH CLIP

SCREWED TO FURRING

FURRING (BY OTHER)

FASTENED TO STRUCTURE

IN FIELD: ACOUSTICAL

BACKER RECOMMENDED

BETWEEN FURRING

3" = 1'-0"

1

LINEAR HORIZONTAL WALL SECTION

1' = 1'-0"

2

DIRECT ATTACHMENT CLIP

LAST REVISED: DRAWN BY:SCALE: AS NOTED

DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS

REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018

123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BMH4/23/2018

AUDITION T&G WALL SYSTEM - HORIZONTAL WALL SECTION

SHEET NUMBER

16

16"

O.C. TYP

JOINTS TO LAND ON FRAMING

START PATTERN FROM BASE

BOARD (FIELD RIP TONGUE)

ACOUSTICAL BACKER

RECOMMENDED

BETWEEN FURRING

FURRING (BY OTHER)

24"

O.C. TYP JOINTS TO LAND ON FRAMING

START PATTERN FROM BASE

BOARD (FIELD RIP TONGUE)

ACOUSTICAL BACKER

RECOMMENDED

BETWEEN FURRING

FURRING (BY OTHER)

1/2" = 1'-0"

1

TYPICAL HORIZONTAL STAGGERED WALL PATTERN - 16 INCH SPACING

1/2" = 1'-0"

2

TYPICAL HORIZONTAL STAGGERED WALL PATTERN - 24 INCH SPACING

LAST REVISED: DRAWN BY:SCALE: AS NOTED

DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS

REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018

123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BMH4/23/2018

AUDITION T&G WALL SYSTEM - HORIZONTAL WALL PATTERN

SHEET NUMBER

17

ALL JOINTS

CENTERED

ON FURRING

TYP. WALL ASSEMBLY

(BY OTHER)

16 GA. FINISH

NAIL (BY OTHER)

T&G DIRECT

ATTACHMENT

CLIP SCREWED TO

FRAMING IN FIELD

TRIM TO COINCIDE W/

FURRING THICKNESS

FASTENED W/ FINISH

NAIL (OPTIONAL)

FURRING (BY OTHER)

FASTENED TO

STRUCTURE IN FIELD:

ACOUSTICAL BACKER

RECOMMENDED

BETWEEN FURRING

1 1/2" = 1'-0"

1

HORIZONTAL WALL SYSTEM ISOMETRIC

LAST REVISED: DRAWN BY:SCALE: AS NOTED

DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS

REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018

123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BMH4/23/2018

AUDITION T&G WALL SYSTEM - HORIZONTAL ISOMETRIC

SHEET NUMBER

18

TYP. WALL

SYSTEM (BY

OTHER)

FIELD CUT END

3

4

" TRIM FASTENED

W/ FINISH NAIL AND

PUTTIED IN FIELD

T&G DIRECT ATTACH CLIP

SCREWED TO FRAMING

FURRING (BY OTHER) FASTENED TO STRUCTURE

IN FIELD: ACOUSTICAL BACKER RECOMMENDED

BETWEEN FURRING

3

4

" TRIM

FASTENED W/

FINISH NAIL

AND PUTTIED

IN FIELD

FURRING (BY OTHER)

FASTENED TO

STRUCTURE IN FIELD:

ACOUSTICAL BACKER

RECOMMENDED

BETWEEN FURRING

3" = 1'-0"

1

HORIZONTAL WALL PLAN @ TRIM

3" = 1'-0"

2

HORIZONTAL WALL ELEVATION @ TRIM

2

LAST REVISED: DRAWN BY:SCALE: AS NOTED

DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS

REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018

123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BMH4/23/2018

AUDITION T&G WALL SYSTEM - HORIZONTAL TRIM CONDITIONS

SHEET NUMBER

19

TYP. WALL SYSTEM

(BY OTHER)

T&G DIRECT ATTACH CLIP

SCREWED TO FRAMING

FURRING (BY OTHER)

FASTENED TO STRUCTURE

IN FIELD: ACOUSTICAL

BACKER RECOMMENDED

BETWEEN FURRING

3" = 1'-0"

1

LINEAR VERTICAL WALL SECTION

1' = 1'-0"

2

DIRECT ATTACHMENT CLIP

LAST REVISED: DRAWN BY:SCALE: AS NOTED

DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS

REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018

123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BMH4/23/2018

AUDITION T&G WALL SYSTEM - VERTICAL WALL SECTION

SHEET NUMBER

20

BASE AS SCHEDULED

(BY OTHER)

START PATTERN

FROM ROOM CENTER

JOINTS TO LAND

ON FRAMING

FACE NAILED AND

PUTTIED IN FIELD @

BASE

HORIZONTAL

FURRING (BY OTHER)

FASTENED TO

STRUCTURE IN FIELD:

ACOUSTICAL BACKER

RECOMMENDED

BETWEEN FURRING

NOTE: START PATTERN

O.C. WITH REVEAL OR

PLANK - WHICHEVER

LEAVES THE LARGEST

POSSIBLE BOARD

WIDTH @ PERIMETER

BASE AS SCHEDULED

(BY OTHER)

START PATTERN

FROM ROOM CENTER

JOINTS TO LAND

ON FRAMING

FACE NAILED AND

PUTTIED IN FIELD @

BASE

HORIZONTAL

FURRING (BY OTHER)

FASTENED TO

STRUCTURE IN FIELD:

ACOUSTICAL BACKER

RECOMMENDED

BETWEEN FURRING

1/2" = 1'-0"

1

VERTICAL WALL PATTERN 1

1/2" = 1'-0"

2

VERTICAL WALL PATTERN 2

LAST REVISED: DRAWN BY:SCALE: AS NOTED

DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS

REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018

123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BMH4/23/2018

AUDITION T&G WALL SYSTEM - VERTICAL WALL PATTERN

SHEET NUMBER

21

ALL JOINTS

CENTERED

ON FRAMING

T&G DIRECT

ATTACHMENT CLIP

SCREWED TO

FRAMING IN FIELD

TYP. WALL SYSTEM

(BY OTHER)

16 GA. FINISH

NAIL (BY OTHER)

HORIZONTAL FURRING

OVER DRYWALL (BY

OTHER): ACOUSTICAL

BACKER RECOMMENDED

BETWEEN FURRING

TRIM TO COINCIDE W/

FURRING THICKNESS

FASTENED W/ FINISH

NAIL (OPTIONAL)

1 1/2" = 1'-0"

1

VERTICAL WALL SYSTEM ISOMETRIC

LAST REVISED: DRAWN BY:SCALE: AS NOTED

DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS

REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018

123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BMH4/23/2018

AUDITION T&G WALL SYSTEM - VERTICAL ISOMETRIC

SHEET NUMBER

22

TYP. WALL SYSTEM

(BY OTHER)

3

4

" TRIM FASTENED W/

FINISH NAIL AND PUTTIED

IN FIELD BY OTHER

FURRING (BY OTHER) FASTENED TO STRUCTURE IN

FIELD: ACOUSTICAL BACKER RECOMMENDED

BETWEEN FURRING

T&G DIRECT ATTACH CLIP

SCREWED TO FRAMING

3

4

" TRIM FASTENED W/

FINISH NAIL AND PUTTIED

IN FIELD BY OTHER

HORIZONTAL FURRING

(BY OTHER) FASTENED

TO STRUCTURE IN FIELD:

ACOUSTICAL BACKER

RECOMMENDED

BETWEEN FURRING

3" = 1'-0"

1

VERTICAL WALL PLAN @ TRIM

3" = 1'-0"

2

VERTICAL WALL ELEVATION @ TRIM

2

LAST REVISED: DRAWN BY:SCALE: AS NOTED

DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS

REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018

123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BMH4/23/2018

AUDITION T&G WALL SYSTEM - VERTICAL TRIM CONDITIONS

SHEET NUMBER

23

LIGHT SWITCH PENETRATION FIELD CUT

FURRING (BY OTHER)

FASTENED TO STRUCTURE

IN FIELD: ACOUSTICAL

BACKER RECOMMENDED

BETWEEN FURRING

T&G DIRECT ATTACH CLIP

SCREWED TO FRAMING

TYP. WALL SYSTEM (BY OTHER)

LIGHT SWITCH PENETRATION FIELD CUT

FURRING (BY OTHER)

FASTENED TO STRUCTURE

IN FIELD: ACOUSTICAL

BACKER RECOMMENDED

BETWEEN FURRING

3" = 1'-0"

1

LIGHT SWITCH DETAIL - ELEVATION

3" = 1'-0"

2

LIGHT SWITCH DETAIL - SECTION

2

LAST REVISED: DRAWN BY:SCALE: AS NOTED

DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS

REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018

123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BMH4/23/2018

AUDITION T&G WALL SYSTEM - LIGHT SWITCH DETAIL

SHEET NUMBER

24

OUTLET PENETRATION FIELD CUT

FURRING (BY OTHER)

FASTENED TO STRUCTURE

IN FIELD: ACOUSTICAL

BACKER RECOMMENDED

BETWEEN FURRING

OUTLET PENETRATION FIELD CUT

T&G DIRECT ATTACH CLIP

SCREWED TO FRAMING

TYP. WALL SYSTEM (BY OTHER)

FURRING (BY OTHER)

FASTENED TO STRUCTURE

IN FIELD: ACOUSTICAL

BACKER RECOMMENDED

BETWEEN FURRING

3" = 1'-0"

1

OUTLET DETAIL - ELEVATION

3" = 1'-0"

2

OUTLET DETAIL - SECTION

2

LAST REVISED: DRAWN BY:SCALE: AS NOTED

DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS

REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018

123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BMH4/23/2018

AUDITION T&G WALL SYSTEM - OUTLET DETAIL

SHEET NUMBER

25

BASE AS SCHEDULED (BY OTHER)

FACE NAIL & PUTTY IN FIELD

FURRING (BY OTHER)

FASTENED TO STRUCTURE

IN FIELD: ACOUSTICAL

BACKER RECOMMENDED

BETWEEN FURRING

T&G DIRECT ATTACH CLIP

SCREWED TO FRAMING

BASE AS SCHEDULED (BY OTHER)

FACE NAIL & PUTTY IN FIELD

FURRING (BY OTHER)

FASTENED TO STRUCTURE

IN FIELD: ACOUSTICAL

BACKER RECOMMENDED

BETWEEN FURRING

3" = 1'-0"

1

BASEBOARD DETAIL - ELEVATION

3" = 1'-0"

2

BASEBOARD DETAIL - SECTION

2

LAST REVISED: DRAWN BY:SCALE: AS NOTED

DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS

REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018

123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BMH4/23/2018

AUDITION T&G WALL SYSTEM - BASEBOARD DETAIL

SHEET NUMBER

26

FIELD CUT

T&G DIRECT ATTACH CLIP

SCREWED TO FRAMING

FACE NAIL IN FIELD

TYPICAL WALL ASSEMBLY (BY OTHER)

FURRING (BY OTHER)

FASTENED TO

STRUCTURE IN FIELD:

ACOUSTICAL BACKER

RECOMMENDED

BETWEEN FURRING

OUTSIDE CORNER

MOULDING

FIELD CUT

FACE NAIL IN FIELD

T&G DIRECT ATTACH CLIP

SCREWED TO FURRING

FURRING (BY OTHER)

FASTENED TO

STRUCTURE IN FIELD:

ACOUSTICAL BACKER

RECOMMENDED

BETWEEN FURRING

3/4"

3/4"

2"

2"

OUTSIDE

CORNER

MOULDING

8' LENGTHS

TYPICAL

3" = 1'-0"

1

VERTICAL PLANK INSIDE CORNER PLAN

3" = 1'-0"

2

VERTICAL PLANK OUTSIDE CORNER PLAN

1' = 1'-0"

3

SECTION (WDOCT)

3

LAST REVISED: DRAWN BY:SCALE: AS NOTED

DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS

REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018

123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BMH4/23/2018

AUDITION T&G WALL SYSTEM - WALL-TO-WALL CORNER

SHEET NUMBER

27

BACKSCREW

IN FIELD

FIELD CUT

FACE NAIL

IN FIELD

T&G DIRECT

ATTACH CLIP

SCREWED TO

FRAMING

15

16

" HEAVY DUTY

T-GRID (BY OTHER)

SUSPENSION

(BY OTHER)

T&G GRID CLIP

WALL ANGLE

(BY OTHER)

FURRING (BY OTHER)

FASTENED TO

STRUCTURE IN FIELD:

ACOUSTICAL BACKER

RECOMMENDED

BETWEEN FURRING

3" = 1'-0"

1

WALL-TO-CEILING TRANSITION

LAST REVISED: DRAWN BY:SCALE: AS NOTED

DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS

REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018

123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BMH4/23/2018

AUDITION T&G SYSTEM - WALL-TO-CIELING TRANSITION

SHEET NUMBER

28

EVERY 6TH PLANK TO BE

BACKSCREWED IN FIELD

FIELD CUT LAP JOINT

SUSPENSION (BY OTHER)

15

16

" HEAVY DUTY

T-GRID (BY OTHER)

T&G GRID CLIP

FURRING (BY OTHER)

FASTENED TO STRUCTURE

IN FIELD: ACOUSTICAL

BACKER RECOMMENDED

BETWEEN FURRING

BACKSREW IN FIELD

FACE NAIL IN FIELDT&G DIRECT ATTACH

CLIP SCREWED TO

FRAMING

* ACOUSTICAL BACKER RECOMMENDED

FIELD CUT LAP JOINT

SUSPENSION (BY OTHER)

15

16

" HEAVY DUTY

T-GRID (BY OTHER)

T&G DIRECT ATTACH CLIP

SCREWED TO FRAMING

HORIZONTAL FURRING

(BY OTHER) FASTENED TO

STRUCTURE IN FIELD:

ACOUSTICAL BACKER

RECOMMENDED

BETWEEN FURRING

T&G GRID CLIP

ACOUSTICAL BACKER

RECOMMENDED

BETWEEN FURRING

* ACOUSTICAL BACKER

RECOMMENDED

3" = 1'-0"

1

HORIZONTAL WALL-TO-VAULTED CEILING

3" = 1'-0"

2

VERTICAL WALL-TO-VAULTED CEILING

LAST REVISED: DRAWN BY:SCALE: AS NOTED

DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS

REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018

123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BMH4/23/2018

AUDITION T&G SYSTEM - WALL-TO-VAULTED CEILING

SHEET NUMBER

29

EVERY 6TH PLANK TO BE

BACKSCREWED IN FIELD

BACKSCREW IN FIELD

SUSPENSION (BY OTHER)

15

16

" HEAVY DUTY

T-GRID (BY OTHER)

MITER IN FIELD

T&G GRID CLIP

* ACOUSTICAL BACKER RECOMMENDED

15

16

" HEAVY DUTY

T-GRID (BY OTHER)

MITER IN FIELD

SUSPENSION

(BY OTHER)

T&G GRID CLIP

BACKSCREW IN FIELD

* ACOUSTICAL BACKER RECOMMENDED

3" = 1'-0"

1

HORIZONTAL VAULTED CEILING RETURN

3" = 1'-0"

2

VERTICAL VAULTED CEILING RETURN

LAST REVISED: DRAWN BY:SCALE: AS NOTED

DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS

REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018

123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BMH4/23/2018

AUDITION T&G SYSTEM - VAULTED CEILING RETURN

SHEET NUMBER

30

SUSPENSION

(BY OTHER)

15

16

" HEAVY DUTY

T-GRID (BY OTHER)

T&G GRID CLIP

USE AUDITION PLANK

FOR FIELD CUT TRIM

FIELD-CUT TRIM OPTION

TO BE FACE-NAILED

AND PUTTIED IN FIELD

* ACOUSTICAL BACKER RECOMMENDED

USE AUDITION PLANK

FOR FIELD CUT TRIM

SUSPENSION

(BY OTHER)

15

16

" HEAVY DUTY

T-GRID (BY OTHER)

FIELD-CUT TRIM OPTION

TO BE FACE-NAILED

AND PUTTIED IN FIELD

T&G GRID CLIP

* ACOUSTICAL BACKER RECOMMENDED

3" = 1'-0"

1

HORIZONTAL VAULTED CEILING PEAK

3" = 1'-0"

2

VERTICAL VAULTED CEILING PEAK

LAST REVISED: DRAWN BY:SCALE: AS NOTED

DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS

REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018

123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BMH4/27/2018

AUDITION T&G SYSTEM - VAULTED CEILING PEAKS

SHEET NUMBER

31

SUSPENSION (BY

OTHER)

15

16

" HEAVY DUTY

T-GRID (BY OTHER)

BACKSCREWED IN FIELD

T&G GRID CLIP

FIELD CUT LAP JOINT

* ACOUSTICAL BACKER RECOMMENDED

FIELD CUT LAP JOINT

SUSPENSION (BY

OTHER)

15

16

" HEAVY DUTY

T-GRID (BY OTHER)

BACKSCREWED IN FIELD

T&G GRID CLIP

* ACOUSTICAL BACKER RECOMMENDED

3" = 1'-0"

1

HORIZONTAL VAULTED CEILING PEAK - LAP JOINT

3" = 1'-0"

2

VERTICAL VAULTED CEILING PEAK - LAP JOINT

LAST REVISED: DRAWN BY:SCALE: AS NOTED

DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS

REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018

123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BMH4/23/2018

AUDITION T&G SYSTEM - VAULTED CEILING PEAKS

SHEET NUMBER

32