Mounting and Operating Instructions
EB 3963 EN
Tran
slatio
n of
orig
inal
instr
uctio
ns
Edition April 2018
Type 3963 Solenoid Valves
2 EB 3963 EN
Note on these mounting and operating instructions
These mounting and operating instructions assist you in mounting and operating the device safely. The instructions are binding for handling SAMSON devices.
Î For the safe and proper use of these instructions, read them carefully and keep them for later reference.
Î If you have any questions about these instructions, contact SAMSON‘s After-sales Service Department (aftersalesservice@samson.de).
The mounting and operating instructions for the devices are included in the scope of delivery. The latest documentation is available on our website at www.samson.de > Service & Support > Downloads > Documentation.
Definition of signal words
Hazardous situations which, if not avoided, will result in death or serious injury
Hazardous situations which, if not avoided, could result in death or serious injury
Property damage message or malfunction
Additional information
Recommended action
DANGER!
WARNING!
NOTICE!
Note
Tip
Contents
EB 3963 EN 3
1 Safety instructions and measures ...................................................................51.1 Notes on possible severe personal injury .........................................................81.2 Notes on possible personal injury ...................................................................91.3 Notes on possible property damage ................................................................92 Markings on the device ...............................................................................102.1 Nameplate ..................................................................................................102.2 Article code .................................................................................................113 Design and principle of operation ................................................................143.1 Accessories .................................................................................................163.2 Technical data .............................................................................................183.3 Dimensions in mm ........................................................................................244 Measures for preparation ............................................................................384.1 Unpacking ..................................................................................................384.2 Storage .......................................................................................................385 Mounting and start-up .................................................................................385.1 Installation ...................................................................................................395.2 Rail mounting ..............................................................................................395.2.1 Wall mounting .............................................................................................405.3 Mounting on rotary actuators with NAMUR interface ......................................405.3.1 Mounting to linear actuators with NAMUR rib ................................................405.3.2 MountingtolinearactuatorsusingCrNiMosteelpipefitting ............................425.3.3 MountingonmountingblockforType 3277LinearActuator ............................425.4 Pneumatic connection ...................................................................................425.4.1 Sizing of the connecting line .........................................................................425.4.2 Compressed air quality .................................................................................445.5 Changeover to external air supply over port 9 ...............................................455.6 Exhaust air feedback ....................................................................................475.7 Restrictions ..................................................................................................476 Electrical connection ....................................................................................486.7.1 SwitchingamplifieraccordingtoEN 60079-25 ..............................................496.7.2 Cableentrywithcablegland ........................................................................496.7.3 Connecttheelectricalpower .........................................................................49
4 EB 3963 EN
Contents
6.1 Degree of protection .....................................................................................496.2 Manual override ..........................................................................................507 Operation ...................................................................................................508 Servicing.....................................................................................................508.1 Preparation for return shipment .....................................................................509 Malfunctions ...............................................................................................519.1 Emergency action ........................................................................................5110 Decommissioning and disassembly ..............................................................5110.1 Decommissioning .........................................................................................5210.2 Disposal ......................................................................................................5211 Appendix ....................................................................................................5211.1 After-sales Service .......................................................................................52
EB 3963 EN 5
Safety instructions and measures
1 Safety instructions and measuresIntended useTheType 3963SolenoidValveismountedontopneumaticlinearorrotaryactuators(de-pending on the version) to control them. Upon failure of the air supply, the solenoid valve vents the actuator, causing the valve to move to the fail-safe position determined by the actu-ator.Thedeviceisdesignedtooperateunderexactlydefinedconditions(e.g.operatingpres-sure, temperature). Therefore, operators must ensure that the solenoid valve is only used in applications where the operating conditions correspond to the technical data. In case opera-torsintendtousethesolenoidvalveinotherapplicationsorconditionsthanspecified,con-tact SAMSON.SAMSON does not assume any liability for damage resulting from the failure to use the de-vice for its intended purpose or for damage caused by external forces or any other external factors.
Î Refertothetechnicaldataandnameplateforlimitsandfieldsofapplicationaswellaspossible uses.
Reasonably foreseeable misuseThe solenoid valve is not suitable for the following applications: − Useoutsidethelimitsdefinedduringsizingandbythetechnicaldata
Furthermore, the following activities do not comply with the intended use: − Use of non-original spare parts − Performingmaintenanceactivitiesnotspecified
Qualifications of operating personnelThe solenoid valve must be mounted, started up, serviced and repaired by fully trained and qualifiedpersonnelonly;theacceptedindustrycodesandpracticesaretobeobserved.Ac-cording to these mounting and operating instructions, trained personnel refers to individuals who are able to judge the work they are assigned to and recognize possible hazards due to their specialized training, their knowledge and experience as well as their knowledge of the applicable standards.Explosion-protected versions of this device are to be operated only by personnel who has un-dergone special training or instructions or who is authorized to work on explosion-protected devices in hazardous areas.
6 EB 3963 EN
Safety instructions and measures
Personal protective equipmentPersonal protective equipment is not required to mount or operate the solenoid valve. Work on the control valve may be necessary when mounting or removing the solenoid valve.
Î Observetherequirementsforpersonalprotectiveequipmentspecifiedinthevalvedocu-mentation.
Î Check with the plant operator for details on further protective equipment.
Revisions and other modificationsRevisions,conversionsorothermodificationsoftheproductarenotauthorizedbySAMSON.They are performed at the user's own risk and may lead to safety hazards, for example. Fur-thermore, the product may no longer meet the requirements for its intended use.
Warning against residual hazardsThe solenoid valve has a direct effect on the control valve when it has been installed. To avoid personal injury or property damage, plant operators and operating personnel must prevent hazards that could be caused in the control valve by the process medium, the operat-ing pressure, the signal pressure or by moving parts by taking appropriate precautions. They must observe all hazard statements, warning and caution notes in these mounting and oper-ating instructions, especially for installation, start-up and service work.
Responsibilities of the operatorThe operator is responsible for proper operation and compliance with the safety regulations. Operators are obliged to provide these mounting and operating instructions as well as the referenced documents to the operating personnel and to instruct them in proper operation. Furthermore, operators must ensure that operating personnel or third persons are not ex-posed to any danger.
Responsibilities of operating personnelOperating personnel must read and understand these mounting and operating instructions as wellasthereferenceddocumentsandobservethespecifiedhazardstatements,warningsand caution notes. Furthermore, the operating personnel must be familiar with the applicable health, safety and accident prevention regulations and comply with them.
Servicing explosion-protected devicesIf a part of the device on which the explosion protection is based needs to be serviced, the devicemustnotbeputbackintooperationuntilaqualifiedinspectorhasassesseditaccord-ingtoexplosionprotectionrequirements,hasissuedaninspectioncertificate,orgiventhedeviceamarkofconformity.Inspectionbyaqualifiedinspectorisnotrequiredifthemanu-
EB 3963 EN 7
Safety instructions and measures
facturer performs a routine test on the device before putting it back into operation. Document the passing of the routine test by attaching a mark of conformity to the device. Replace ex-plosion-protected components only with original, routine-tested components by the manufac-turer.Devices that have already been operated outside hazardous areas and are intended for fu-ture use inside hazardous areas must comply with the safety requirements placed on serviced devices. Before being operated inside hazardous areas, test the devices according to the specificationsforservicingexplosion-protecteddevices.
Maintenance, calibration, and work on equipment Î Only use intrinsically safe current/voltage calibrators and measuring instruments for in-terconnection with intrinsically safe circuits to check or calibrate the equipment inside or outside hazardous areas.
Î Observethemaximumpermissiblevaluesspecifiedinthecertificatesforintrinsicallysafecircuits.
Referenced standards and regulationsThe solenoid valves comply with the requirements of Directives 2014/30/EU and 2014/35/EU for not explosion-protected applications as well as Directive 2014/34/EU for explo-sion-protected applications. The declaration of conformity includes information about the ap-plied conformity assessment procedure. This declaration of conformity is included in the ap-pendix of these instructions.
Referenced documentationThe following documents apply in addition to these mounting and operating instructions: − The mounting and operating instructions of the components on which the solenoid valve
is mounted (valve, actuator, valve accessories, etc.) − Safety manual of the solenoid valve u SH 3963
The mounting and operating instructions for all supplied SAMSON devices are included in the delivery. The latest versions of the documents are available on our website at u www.samson.de>Productdocumentation.
8 EB 3963 EN
Safety instructions and measures
1.1 Notes on possible severe personal injury
DANGER!
Risk of electric shock.Before starting up the solenoid valve, electrical installation work must be performed. An electric shock due to incorrect work practices may cause death.
Î Before connecting wiring, performing any work on the device or opening the device, disconnect the power supply and protect it against unintentional reconnection.
Î For electrical installation, observe the relevant electrotechnical regulations and the accident prevention regulations that apply in the country of use.
Risk of fatal injury due to the formation of an explosive atmosphere.
Incorrect installation, operation or maintenance of the solenoid valve in potentially ex-plosive atmospheres may lead to ignition of the atmosphere and cause death.
Î Thefollowingregulationsapplytoinstallationinhazardousareas:EN 60079-14:2008(VDE 0165,Part 1).
Î Installation, operation or maintenance of the solenoid valve must only performed by personnel who has undergone special training or instructions or who is authorized to work on explosion-protected devices in hazardous areas.
Î ObservethetypeofprotectionandtheconditionsforcontrolspecifictothetypeofprotectionaccordingtotheECtypeexaminationcertificate.
EB 3963 EN 9
Safety instructions and measures
1.2 Notes on possible personal injury
WARNING!
Risk of personal injury due to moving parts on the valve.During operation and when the solenoid valve is triggered, the actuator stem moves throughitsentiretravelrange.Injurytohandsorfingersispossibleiftheyareinsertedinto the valve.
Î Whilethevalvemoves,donotinserthandsorfingersintothevalveyokeanddonottouch any moving valve parts.
1.3 Notes on possible property damage
NOTICE!
Risk of damage to the solenoid valve due to incorrect mounting position. Î Do not mount the solenoid valve with the vent opening facing upward. Î Do not seal the vent opening when the device is installed on site.
Risk of damage to the solenoid valve due to impermissible pressures. Î Do not connect a supply pressure to the solenoid valve that exceeds the maximum supply pressure.
Incorrect assignment of the terminals will damage the solenoid valve and will lead to malfunction.For the solenoid valve to function properly, the prescribed terminal assignment must be observed.
Î Connect the electrical wiring to the solenoid valve according to the prescribed termi-nal assignment.
10 EB 3963 EN
Markings on the device
2 Markings on the device
2.1 NameplateVersions without explosion protection
24 V DC
00
0000 0000 0000 00000
GI 0000000
0000 0000 0000 00000
02/18
000000000
1
234 5
Versions with explosion protection
00 0000 0000 000000000000
GI 00
3000000000
02/18
1
56 6
243
1 Nominal signal2 Article code3 ConfigurationID4 Serial number5 Device index6 Seesection 3.2.
EB 3963 EN 11
Markings on the device
2.2 Article codeSolenoid valve Type 3963- x x x x x x x x x x x x x x x x xType of protectionNo explosion protection SIL 0II 2G Ex ia IIC T6 Gb(ATEX) 1) SIL 1Ex ia(CSA/FM) SIL 3II 3G Ex nA II T6 Gc/II 3G Ex ic IIC Gc(ATEX) 2) SIL 8Nominal signal6 V DC SIL 112 VDC SIL 224 V DC SIL 3230 V AC SIL 5115 VAC SIL 6Manual overrideWithout SIL 0Pushbutton underneath the enclosure cover SIL 1External pushbutton (accessible using a pin) 2External switch (accessible using a screwdriver) 3Switching function3/2-way function with spring-return mechanism SIL 05/2-way function with spring-return mechanism (SIL with KVS 0.16) 15/2-way function with spring-return mechanism with detented positions 25/2-way function with spring-centered mid-position (ports 2 and 4 closed)
3
5/2-way function with spring-centered mid-position (ports 2 and 4 vented)
5
6/2-way function with spring-return mechanism 81) ECtypeexaminationcertificatePTB 01 ATEX 20852) StatementofconformityPTB01ATEX2086X
(continuedonpage 12)
12 EB 3963 EN
Markings on the device
Solenoid valve Type 3963- x x x x x x x x x x x x x x x x xRestrictionsWithout SIL 0One exhaust air restriction 1Two exhaust air restriction 2One supply air restriction/one exhaust air restriction 3AttachmentNAMURinterfaceaccordingtoVDI/VDE 3845 SIL 0Threaded connection for rail, wall or pipe mounting SIL 1NAMURribsaccordingtoIEC 60534-6-1 SIL 2MountingblockforType 3277LinearActuator SIL 3ConnectiondiagramofType 3963(assparepart) SIL 4KVS 1)
0.16 SIL 10.32 SIL 21.4 34.3 SIL 40.01 (as spare part) 52.9 62.0 SIL 7Pneumatic connectionG ¼ SIL 0¼ NPT SIL 1G ½ SIL 2½ NPT SIL 3Without (as spare part) 4Air supplyInternal (for actuators for on/off service or mounting block) SIL 0External (actuators for throttling service) SIL 11) Theairflowratewhenp1=2.4 barandp2=1.0 bariscalculatedusingthefollowingformula:
Q = KVS x 36.22 in m³/h.
(continuedonpage 13)
EB 3963 EN 13
Markings on the device
Solenoid valve Type 3963- x x x x x x x x x x x x x x x x xElectrical connectionBlanking plug M20x1.5 SIL 0 0Cable gland M20x1.5 made of black polyamide SIL 0 1M20x1.5 cable gland made of blue polyamide SIL 1 1AdapterM20x1.5to½ NPT(aluminum) SIL 1 2CableglandM20x1.5(CEAG)madeofblackpolyamide SIL 1 3Cable gland M20x1.5, nickel-plated brass SIL 1 4Cable gland M20x1.5, nickel-plated brass, blue SIL 1 5CableglandM20x1.5(CEAG)madeofbluepolyamide SIL 1 6Cable gland M20x1.5 (Jacob) made of blue polyamide SIL 1 7DeviceconnectoraccordingtoDIN EN 175301-803,blackpolyamide 1) SIL 2 3DeviceconnectorwithLEDaccordingtoDIN EN 175301-803,blackpolyamide 2) SIL 2 5AdapterM20x1.5to½ NPT(stainlesssteel) SIL 2 6Degree of protectionIP 54withpolyethylenefilter SIL 0IP 65withfiltercheckvalvemadeofpolyamide SIL 1IP 65withfiltercheckvalvemadeofstainlesssteel SIL 2NEMA 4withfiltercheckvalvemadeofpolyamide SIL 4NEMA 4withfiltercheckvalvemadeofstainlesssteel SIL 5Ambient temperature 3)
–20to+80 °C(+60 °CintemperatureclassT6) SIL 0–45to+80 °C(+60 °CintemperatureclassT6) SIL 2Safety functionWithout 0SIL 4) SIL 1TÜV 5) 2Special versionWithout SIL 0 0 0Connecting plate/booster valve made of 1.4404 SIL 0 0 1Further special versions on request
1) The cable socket is not included in the scope of delivery.2) ThecablesocketwithLEDisincludedinthescopeofdelivery.3) The maximum permissible ambient temperature of the solenoid valve depends on the permissible ambient tem-
perature of the components, type of protection and temperature class.4) SILaccordingtoIEC 615085) Emergency release or locking of compressed air supply
14 EB 3963 EN
Design and principle of operation
3 Design and principle of oper-ation
Solenoid valves actuated on one sideThe solenoid valves consist of an electro-pneumatic binary converter with (option-al) manual override and a booster valve
actuated on one side with return spring (Fig. 1).The air supply for the electropneumatic bina-ry converter is routed internally through the booster valve (delivered state). The so-
lenoid valve can be converted to accept an external air supply at port 9 by turning a gasket.The pressure reducer reduces the supply airpressureto1.4 bar.Intheidleposition,theflapper is lifted off the outlet nozzle by the spring . As a re-sult, a pressure lower than the deactivation pressure of the booster valve builds up in the pressure divider, which consists of the re-strictor and outlet nozzle .
+81
–82
Ⓑ
Ⓐ
Ⓒ
9
5
3
4
1
23
4 4
56
Nominal signal
Changeover to external air supply
Fig. 1: Function
EB 3963 EN 15
Design and principle of operation
When the solenoid coil is energized by an electric binary signal, the outlet nozzle isclosedbytheflapper against the force of the spring . This causes the pressure in the pressure divider to rise above the switch-on pressure of the booster valve and switches it to the operating position.After the solenoid coil is de-energized, the booster valve is switched to the idle posi-tion again by a return spring.
Solenoid valves actuated on both sidesThe solenoid valves consist of two electro-pneumatic binary converters with (option-al) manual override and a booster valve
actuated on both sides with two detent positions or spring-centered mid-position.The air supply for the electropneumatic bina-ry converters is routed internally through the booster valve (delivered state). The so-lenoid valve can be converted to accept an external air supply at port 9 by turning two gaskets.The pressure reducer reduces the supply airpressureto1.4 bar.Intheidleposition,theflapper is lifted off the outlet nozzle by the spring . As a re-sult, a pressure lower than the deactivation pressure of the booster valve builds up in the pressure divider, which consists of the re-strictor and outlet nozzle .When the solenoid coil is energized by an electric binary signal, the outlet nozzle isclosedbytheflapper against the force of the spring . This causes the pressure in the pressure divider to rise above the switch-
on pressure of the booster valve and switches it to the operating position.After the solenoid coil is de-energized, the operating position of the detented booster valve is kept until the opposing signal is received. The spring-centered booster valve
is switched to the mid-position by a return spring after the solenoid coil is de-ener-gized.A simultaneous control of the electropneu-matic binary converter must be ruled out on the electric control level.
16 EB 3963 EN
Design and principle of operation
3.1 AccessoriesAccessories for Type 3963 Solenoid ValvesOrder no. Designation0790-6658 CablesocketaccordingtoEN 175301-803,FormA,madeofpolyamide,black,degreeofprotection
IP 651170-4069 CablesocketwithLEDaccordingtoEN 175301-803,FormA,madeofpolyamide,black,degreeof
protectionIP 651400-8298 Cablesocket(Harting),7-pole,madeofaluminum,silver,degreeofprotectionIP 658801-2810 Sensorconnectinglead,two-wire,3 m,blue,withangleconnectorM12 x 1,4-pole,degreeofprotec-
tionIP 688831-0716 Cablesocket(Binder),7-pole,madeofPBTGV,black,degreeofprotectionIP 678831-0865 CablesocketM12 x 1,4-pole,angleddesign,madeofpolyamide,black,degreeofprotectionIP 67
3994-0158 Cablebreakageprotectionwithenclosurefor35 mmtop-hatrailmounting,degreeofprotectionIP 20(forType 3963-X1with6 V DCsolenoid)
1400-5268 Filtermadeofpolyethylene,G 1/G ½connection,degreeofprotectionIP 54(requiredforactuatorsize>1400 cm²)
8504-0066 Filtermadeofpolyethylene,G ¼connection,degreeofprotectionIP 548504-0068 Filtermadeofpolyethylene,G ½connection,degreeofprotectionIP 54
1790-7408 FiltercheckvalveinhousingwithG ¼threadmadeofpolyamide,degreeofprotectionIP 651790-7253 FiltercheckvalveinhousingwithG ¼threadmadeof1.4301,degreeofprotectionIP 651790-9645 FiltercheckvalveinhousingwithG ¼threadmadeofpolyamide,degreeofprotectionNEMA41790-9646 FiltercheckvalveinhousingwithG ¼threadmadeof1.4301,degreeofprotectionNEMA4
1400-5930 MountingbaseforG-profilerail32accordingtoEN 50035(2pcs.required)1400-5931 Mountingbasefor35 mmtop-hatrailaccordingtoEN 50022(2pcs.required)1400-6726 Mounting plate for wall mounting
Mounting kits for Type 3963 Solenoid Valves with threaded connectionsOrder no. Designation1400-6759 Mountingkitforlinearactuators(80and240 cm²actuatorarea,G ¼connection)withpipefitting,
G ¼/G ¼connection,madeofCrNiMosteel
Mountingkitforlinearactuators(350and700 cm²actuatorarea,G 3/8 connection)1400-6735 withpipefitting,G ½/G 3/8 connection, made of CrNiMo steel1400-6761 withpipefitting,G ¼/G 3/8 connection, made of CrNiMo steel
1400-6736 Mountingkitforlinearactuators(1400 cm²actuatorarea,G ¾connection)withpipefitting,G ½/G ¾connection, made of CrNiMo steel
1400-6737 Mountingkitforlinearactuators(2800 cm²actuatorarea,G 1connection)withpipefitting,G ½/G 1connection, made of CrNiMo steel
EB 3963 EN 17
Design and principle of operation
Mounting kits for Type 3963 Solenoid Valves with threaded connectionsOrder no. Designation
Mountingkitforlinearactuators(80and240 cm²actuatorarea,G ¼connection)withmountingbracket made of CrNiMo steel
1400-6749 andscrewfittingsfor8×1pipe,G ¼/G ¼connection,madeofzinc-coatedsteel1400-6750 andscrewfittingsfor8×1pipe,G ¼/G ¼connection,madeofCrNiMosteel
Mountingkitforlinearactuators(350and700 cm²actuatorarea,G 3/8 connection) with mounting bracket made of CrNiMo steel
1400-6738 andscrewfittingsfor8×1pipe,G ¼/G 3/8 connection, made of zinc-coated steel1400-6739 andscrewfittingsfor8×1pipe,G ¼/G 3/8 connection, made of CrNiMo steel1400-6743 andscrewfittingsfor12×1pipe,G ¼/G 3/8 connection, made of CrNiMo steel1400-6744 andscrewfittingsfor10×1pipe,G ½/G 3/8 connection, made of polyamide1400-6745 andscrewfittingsfor10×1pipe,G ¼/G 3/8 connection, made of polyamide
Mountingkitforlinearactuators(700 cm²actuatorarea,G 3/8 connection) with mounting bracket made of CrNiMo steel
1400-6740 andscrewfittingsfor12×1pipe,G ½/G 3/8 connection, made of zinc-coated steel1400-6741 andscrewfittingsfor12×1pipe,G ¼/G 3/8 connection, made of zinc-coated steel1400-6742 andscrewfittingsfor12×1pipe,G ½/G 3/8 connection, made of CrNiMo steel
Mounting kits for Type 3963 Solenoid Valves with NAMUR interfaceOrder no. Designation
Mountingkitforlinearactuators(350and700 cm²actuatorarea,G 3/8 connection) with NAMUR rib usingadapterplateforNAMURrib/interface(orderno.1400-6751)
1400-6746 andscrewfittingsfor12×1pipe,G ¼/G 3/8 connection, made of zinc-coated steel1400-6747 andscrewfittingsfor12×1pipe,G ¼/G 3/8 connection, made of CrNiMo steel1400-6748 andscrewfittingsfor10×1pipe,G ¼/G 3/8 connection, made of polyamide
Mountingkitforlinearactuators(80and240 cm²actuatorarea,G ¼connection)withNAMURribus-ingadapterplateforNAMURrib/interface(orderno.1400-6751)
1400-6752 andscrewfittingsfor6×1pipe,G ¼/G ¼connection,madeofzinc-coatedsteel1400-6753 andscrewfittingsfor6×1pipe,G ¼/G ¼connection,madeofCrNiMosteel1400-6756 andscrewfittingsfor10×1hose,G ¼/G ¼connection,madeofpolyamide
Mountingkitforlinearactuators(350and700 cm²actuatorarea,G 3/8 connection) with NAMUR rib usingadapterplateforNAMURrib/interface(orderno.1400-6751)
1400-6754 andscrewfittingsfor8×1pipe,G ¼/G 3/8 connection, made of zinc-coated steel1400-6755 andscrewfittingsfor8×1pipe,G ¼/G 3/8 connection, made of CrNiMo steel1400-6757 andscrewfittingsfor10×1pipe,G ¼/G 3/8 connection, made of polyamide
1400-6759 Mountingkitforlinearactuators(80and240 cm²actuatorarea,G ¼connection)withpipefitting,G ¼/G ¼connection,madeofCrNiMosteel
1400-3001 MountingkitforType 3353AngleSeatValvewithadapterplateforNAMURinterfacemadeof1.4301
18 EB 3963 EN
Design and principle of operation
Accessories for mounting kitsOrder no. Designation0320-1416 Support for NAMUR rib (required when a positioner or limit switch is additionally mounted to the
linearactuator,DN 50)8320-0131 M8x60hexagonscrew,A4,DIN 931
1400-6751 AdapterplatewithNAMURrib/NAMURinterface(G ¼)1400-9924 AdapterplatewithNAMURrib/NAMURinterface(¼ NPT)
MountingblockforSAMSONType 3277LinearActuatorwithmountedTypes 3793,3766,3767and3730Positioners
1400-8813 G ¼connection1400-8814 ¼ NPTconnection
1400-6950 Pressure gauge mounting block, 1x Output and 1x Supply, made of stainless steel/brass (for mounting block)
Piping for actuator with "stem retracts" fail-safe action1400-6444 240 cm²actuatorarea,zinc-coatedsteel1400-6445 240 cm²actuatorarea,CrNiMosteel1400-6446 350 cm²actuatorarea,zinc-coatedsteel1400-6447 350 cm²actuatorarea,CrNiMosteel1400-6448 700 cm²actuatorarea,zinc-coatedsteel1400-6449 700 cm²actuatorarea,CrNiMosteel
3.2 Technical dataGeneral dataType Solenoidwithflapper/nozzleassemblyandboostervalvewithreturnspring
Actuation Electricallyactuatedononeside(seeElectricdata,page 19)
Degree of protection IP 54withfilter, IP 65withfiltercheckvalve
Compressed air quality accordingtoISO 8573-1
Particle size and density: Class 4 · Oil content: Class 3 · Pressure dew point: Class 3 or at least10 Kbelowthelowestambienttemperaturetobeexpected
Supply air Instrument air (free from corrosive substances) or nitrogen
Supply pressure 1.4to6.0 bar
Air consumption (binary e/p converter)
≤10 l/hat1.4barsupplyairinoperatingposition, ≤80 l/hat1.4barsupplyairinidleposition
Switching time ≤65 ms
Electrical connection Cable entry M20x1.5 to screw terminal, two pole, or connector
EB 3963 EN 19
Design and principle of operation
Electric dataType 3963 -x1 -x2 -x3 -08 -07 -06 -05Nominal signal
UN 6 V DC 12 VDC 24 V DC 24 VAC 48 V AC 115 VAC 230 V AC
Umax 1) 27 V 25 V 32 V 36 V 80 V 130 V 255 V
fN – 48 to 62 Hz
Switching point
On U+80 °C ≥4.8 V ≥9.6 V ≥18 V 19to36 V 42to80 V 82to130 V 183to255 V
On I+20 °C ≥1.41mA ≥1.52mA ≥1.57mA ≥1.9mA ≥1.9mA ≥2.2mA ≥2.6mA
On P+20 °C ≥5.47 mW ≥13.05 mW ≥26.71 mW ≥0.04 VA ≥0.07 VA ≥0.17 VA ≥0.46 VA
Off U–25 °C ≤1.0 V ≤2.4 V ≤4.7 V ≤4.5 V ≤9.0 V ≤18.0 V ≤36.0 V
Impedance
R+20 °C 2.6 kΩ 5.5 kΩ 10.7 kΩ Approx. 10 kΩ
Approx. 24 kΩ
Approx. 40 kΩ
Approx. 80 kΩ
Temperature influenceonR 0.4 %/°C 0.2 %/°C 0.1 %/°C 0.1 %/°C 0.1 %/°C 0.05 %/°C 0.03 %/°C
Type of protection Ex ia IIC 2) for use in hazardous areas (Zone 1)Type 3963 -11 -12 -13Nominal signal
UN 6 V DC 12 VDC 24 V DC
SeeECtypeexaminationcertificatePTB 01 ATEX 2085formaximumpermissiblevalueswhenconnectedtoacertifiedintrinsically safe circuit.
Type of protection Ex nA II 3) for use in hazardous areas (Zone 2)Type 3963 -81 -82 -83Nominal signal
UN 6 V DC 12 VDC 24 V DC
SeestatementofconformityPTB 01 ATEX 2086 Xformaximumpermissiblevalueswhenconnectedtoacertifiedintrinsically safe circuit.
1) Maximumpermissiblevalueat100 %dutycycle.ThemaximumpermissiblevalueUi applies to explosion-protected versions.
2) MarkingII 2G Exia IIC T6Gb(gasesinZone 1)3) MarkingII 3G Ex nA II T6Gc/II 3G Ex ic IIC T6Gc(gasesinZone 2)
(continuedonpage 20)
20 EB 3963 EN
Design and principle of operation
Solenoid valve with threaded connection, KVS 0.16/0.32Type 3963 -xxx0x11 -xxx0x12 -xxx1x11 -xxx8x11Switching function 3/2-way function 3/2-way function 5/2-way function 6/2-way functionKVS 1) 0.16 0.32 0.16 0.16Fail-safe action SIL 2),TÜV 3) SIL 2),TÜV 3) SIL 2),TÜV 3) –Type Diaphragm switching element, soft seated, with return springMaterial Enclosure: Black polyamide
Connecting plate: Aluminum,powdercoated,graybeigeRAL 1019orstainlesssteel1.4404
Springs: Stainless steel 1.4310Screws: Stainlesssteel1.4571Seals: Silicone rubber, PerbunanDiaphragms: Chloroprenerubber(–20to+80 °C),siliconerubber(–45to+80 °C)
Operating medium Instrument air (free from corrosive substances) or nitrogen 4), air containing oil or non-cor-rosive gases 5)
Max. operating pressure 6.0 barOutput signal Operating pressurePneumatic connection G ¼or¼ NPTAmbient temperature 6) –20to+80 °C(chloroprenerubber)or–45to+80 °C(siliconerubber)Approx. weight 0.57 kgSolenoid valve with threaded connection, KVS 4.3Type 3963 -xxx0x14 -xxx0x14 -xxx1x14 -xxx8x14Switching function 3/2-way function 3/2-way function 5/2-way function 8) 6/2-way function 8)
KVS 1)(directionofflow) 4.3 (3 → 5),4.7 (5 → 3),1.9 (4 → 3),1.5 (3 → 4)
Fail-safe action SIL 2),TÜV 3) SIL 2),TÜV 3) – –Type Poppet valve with switching diaphragm, soft seated, with return springMaterial Enclosure: Black polyamide (pilot valve), aluminum, powder coated, gray beige
RAL 1019,orstainlesssteel1.4404(boostervalve)Springs: Stainless steel 1.4310Screws: Stainlesssteel1.4571Seals: Chloroprenerubber(–20to+80 °C),siliconerubber(–45to+80 °C)Diaphragms: Chloroprenerubber(–20to+80 °C),siliconerubber(–45to+80 °C)
Operating medium Instrument air (free from corrosive substances) or nitrogen 4), air containing oil or non-corrosive gases 5)
Max. operating pressure 10.0 bar(directionofflow4 → 3,3 → 5),2.0 bar(anydirectionofflow)Output signal Operating pressureAmbient temperature 6) –20to+80 °C(chloroprenerubber)or–45to+80 °C(siliconerubber)Pneumatic connection G ¼or¼ NPTApprox. weight 0.58 kg 0.58 kg 1.1 kg 1.1 kg
EB 3963 EN 21
Design and principle of operation
Solenoid valve with NAMUR interface, KVS 0.16/0.32Type 3963 -xxx0x01 -xxx0x02 -xxx1x01 -xxx8x01Switching function 3/2-way function 3/2-way function 5/2-way function 6/2-way functionKVS 1) 0.16 0.32 0.16 0.16Fail-safe action SIL 2),TÜV 3) SIL 2),TÜV 3) SIL 2),TÜV 3) –Type Diaphragm switching element, soft seated, with return springMaterial Enclosure: Black polyamide
Connecting plate: Blackpolyamide,aluminum,powdercoated,graybeigeRAL 1019,orstainless steel 1.4404
Springs: Stainless steel 1.4310Screws: Stainlesssteel1.4571Seals: Silicone rubber, PerbunanDiaphragms: Chloroprenerubber(–20to+80 °C),siliconerubber(–45to+80 °C)
Operating medium Instrument air (free from corrosive substances) or nitrogen 4), air containing oil or non-corrosive gases 5)
Max. operating pressure 6.0 barOutput signal Operating pressurePneumatic connection G ¼or¼ NPTandNAMURinterface ¼" 7)
Ambient temperature 6) –20to+80 °C(chloroprenerubber)or–45to+80 °C(siliconerubber)Approx. weight 0.57 kgSolenoid valve with NAMUR interface, KVS 2.0Type 3963 -xxx0x07Switching function 3/2-way function with exhaust air feedbackKVS 1) 2.0 (directionofflow3 → 5),1.1 (directionofflow4 → 3)Fail-safe action SIL 2),TÜV 3)
Type Poppet valve with switching diaphragm, soft seated, with return springMaterial Enclosure: Black polyamide (pilot valve), aluminum, powder coated, gray beige
RAL 1019,orstainlesssteel1.4404(boostervalve)Springs: Stainless steel 1.4310Screws: Stainlesssteel1.4571Seals: Chloroprenerubber(–20to+80 °C),siliconerubber(–45to+80 °C)Diaphragms: Chloroprenerubber(–20to+80 °C),siliconerubber(–45to+80 °C)
Operating medium Instrument air (free from corrosive substances) or nitrogen 4), air containing oil or non-corrosive gases 5)
Max. operating pressure 10.0 barOutput signal Operating pressureAmbient temperature 6) –20to+80 °C(chloroprenerubber)or–45to+80 °C(siliconerubber)Pneumatic connection Supply air: G ¼or¼ NPTandNAMURinterface ¼" 7)withG 3/8
Exhaust air: G ½or½ NPTandNAMURinterface ¼" 7)withG 3/8
Approx. weight 1.38 kg
22 EB 3963 EN
Design and principle of operation
Solenoid valve with NAMUR interface, KVS 4.3Type 3963 -xxx0x04Switching function 3/2-way function with exhaust air feedbackKVS 1) 4.3 (directionofflow3 → 5),1.9 (directionofflow4 → 3)Fail-safe action SIL 2),TÜV 3)
Type Poppet valve with switching diaphragm, soft seated, with return springMaterial Enclosure: Black polyamide (pilot valve), aluminum, powder coated, gray beige
RAL 1019,orstainlesssteel1.4404(boostervalve)Springs: Stainless steel 1.4310Screws: Stainlesssteel1.4571Seals: Chloroprenerubber(–20to+80 °C),siliconerubber(–45to+80 °C)Diaphragms: Chloroprenerubber(–20to+80 °C),siliconerubber(–45to+80 °C)
Operating medium Instrument air (free from corrosive substances) or nitrogen 4), air containing oil or non-corrosive gases 5)
Max. operating pressure 10.0 barOutput signal Operating pressureAmbient temperature 6) –20to+80 °C(chloroprenerubber)or–45to+80 °C(siliconerubber)Pneumatic connection G ½or½ NPTandNAMURinterface ½" 7)
Approx. weight 1.5 kg
1) Theairflowratewhenp1=2.4 barandp2=1.0 bariscalculatedusingthefollowingformula: Q = KVS x 36.22 in m³/h.
2) SILaccordingtoIEC 615083) Emergency release or locking of compressed air supply4) With internal air supply5) With external air supply6) The maximum permissible ambient temperature depends on the permissible ambient temperature of the cable
gland, type of protection and temperature class.7) NAMURinterfaceaccordingtoVDI/VDE 38458) Connectinghosebetweenboostervalvesmadeofpolyamide,seepages 28and29
EB 3963 EN 23
Design and principle of operation
Table 1: Summary of explosion protection approvals
Type Certification Type of protection/comments
3963
-1
EC type examina-tioncertificate
Number PTB 01ATEX2085II2GExiaIICT6Gb
Date 2011-08-08
Number RUC-DE.08.B.00764
1ExiaIICT6/T5/T4GbXDate 2015-02-10
Validuntil 2020-02-09
KCSNumber 13-KB4BO-0039
Ex ia IIC T6/T5/T4Date 2013-01-31
Validuntil 2019-01-31
NEPSINumber GYJ15.1220X
ExiaIICT4~T6GbDate 2016-06-16
Validuntil 2020-06-15
-3
CSANumber 1607857
ExiaIICT6;ClassI,Zone0; ClassI,II,Div.1,GroupsA,B,C,D,E,F,G; ClassI,II,Div.2,GroupsA,B,C,D,E,F,G; ClassIII;Type4Enclosure
Date 2005-09-16
FMNumber 3020228
ClassI,Zone0AExiaIIC; ClassI,II,III;Div.1,GroupsA,B,C,D,E,F,G; ClassI,Div.2,GroupsA,B,C,D; ClassII,Div.2GroupsF,G; ClassIII;Type4X
Date 2015-10-12
-8
Statement of conformity
Number PTB 01ATEX2086X II3GExnAIIT6Gc; II3GExicIICT6GcDate 2017-04-17
Number RUC-DE.08.B.007642ExnAIICT6/T5/T4; 2Ex ic IIC T6/T5/T4Date 2015-02-10
Validuntil 2020-02-09
NEPSINumber GYJ15.1220X
ExicIICT4~T6GcDate 2016-06-16
Validuntil 2020-06-15
24 EB 3963 EN
Design and principle of operation
3.3 Dimensions in mmSolenoid valves without threaded connections
Type 3963-xxx0x4541: pilot valve, KVS 0.01
Type 3963-xxx0x414: pilot valve, KVS 0.16
61
62
31 38
80
62
31
Cable gland M20x1.5
Screw plug M20x1.5
Screw plug M20x1.5
Cable gland M20x1.5
61
63
31 38 31
62 62
EB 3963 EN 25
Design and principle of operation
Solenoid valves with threaded connectionsType 3963-xxx1x11: 5/2-way solenoid valve, actuated on one side, KVS 0.16
Bottom view of connecting plateM4/7 mmdeep M3/6 mmdeep Ø3 mm/3.5 mmdeep
Cable gland M20x1.5
Screw plug M20x1.5
2.5 1.594
1.3 2.3
�62
2510
31
124
61 31
1025
38
40 40
�62
28 38 48
���
���
Type 3963-xxx0x11/: 5/2-way solenoid valve, actuated on one side, KVS 0.16 or 3.2
Bottom view of connecting plateM4/7 mmdeep M3/6 mmdeep Ø3 mm/3.5 mmdeep
Cable gland M20x1.5
Screw plug M20x1.5
Port9inType 3963-xxx0x11x0xxxx Port4inType 3963-xxx0x12xxxxxx Ports9and5inType 3963-xxx0x12xxxxxx
1919
3 959(4)
31
109
61 31 38
10
29
10
�6240 40
�62
28 38 48
���
���
26 EB 3963 EN
Design and principle of operation
Type 3963-xxx8x11: 6/2-way solenoid valve, actuated on one side, KVS 0.16
1.4 2.4
1.3 2.32.5 1.5
9
31
129
61 31 38
3410
49
�6239
242542
40
�62
28 38 48
���
���
Bottom view of connecting plateM4/7 mmdeep M3/6 mmdeep Ø3 mm/3.5 mmdeep
Cable gland M20x1.5
Screw plug M20x1.5
Types 3963-xxx0x314/-xxx0x324: 3/2-way solenoid valve, actuated on one side, KVS 0.16 or 0.32, for mounting to linear actuators using a mounting block
2422
.5
22.512
60
61 31 38 31
108.
5
16
12
16 60
*
*
Cable gland M20x1.5
Screw plug M20x1.5
* Mounting to a mounting block using twoM5x60(DIN 912)screws
EB 3963 EN 27
Design and principle of operation
Type 3963-xxx0x14: 3/2-way solenoid valve, actuated on one side, KVS 4.3
64
5321 21
29
3565
7
193
315053
34
94,5
38
62
31
9
4
5
3
99
Int
½"
½"
½"
Cable gland M20x1.5
Screw plug M20x1.5
G ½blankingplug
28 EB 3963 EN
Design and principle of operation
Type 3963-xxx1x14: 5/2-way solenoid valve, actuated on one side, KVS 4.3
4 3
64
38100
135 11
22
34
53 35
194
65
21 21
53
94,5
5
31
50
64 29
M6 G ½
G ½
G ½
Cable gland M20x1.5
Screw plug M20x1.5
G ½blankingplug
EB 3963 EN 29
Design and principle of operation
Type 3963-xxx1x14: 5/2-way solenoid valve, actuated on one side, KVS 4.3
M6
135100
38
11
22
5321 21
35
64 29
94.5
50
31 3453
194
6465
4 3
5
G ½
G ½
G ½
Cable gland M20x1.5
Screw plug M20x1.5
G ½blankingplug
30 EB 3963 EN
Design and principle of operation
Types 3963-xxx0x13/-xxx1x13: 3/2-way or 5/2-way solenoid valve, actuated on one side, KVS 1.4
5
1
3
4
2
9 9Int
22
4.3
3250.8
44.4
47
22
61 31
122
47
1356
14
¼"
Cable gland M20x1.5
G ½blankingplug
Port 5 is sealed when the 3/2-way function is used
Screw plug M20x1.5
Types 3963-xxx2x13/-xxx3x13/-xxx5x13: 5/2-way or 5/3-way solenoid valve, actuated on both sides, KVS 1.4
5617
1461 31
4.3
2222
3250.8
44.4
4747
122
122
Int
Int
99
9
9
1
5
3
14
12
4
2
¼"
Cable gland M20x1.5
G ½blankingplug
Screw plug M20x1.5
EB 3963 EN 31
Design and principle of operation
Solenoid valves with threaded connections for linear actuators with NAMUR ribType 3963-xxx0x22: 3/2-way solenoid valve, actuated on one side, KVS 0.32
61 31
9
5
3
4
16.860°
40
1419
8.4
62
23
80
40
1019
70 12
626
109
38 31
G ¼
Screw plug M20x1.5
Bottom view of adapter plate
Cable gland M20x1.5
Types 3963-xxx0x01/-xxx1x01: 3/2-way or 5/2-way solenoid valve, actuated on one side, KVS 0.16
62
88
24
25
63
3161
1.3 2.3
4
12.5
3138
253669
96
6232
Screw plug M20x1.5
Cable gland M20x1.5
NAMURfixinglevel
32 EB 3963 EN
Design and principle of operation
Type 3963-xxx0x02: 3/2-way solenoid valve, actuated on one side, KVS 0.32
Screw plug M20x1.5
NAMURfixinglevel
Cable gland M20x1.5
42.3
1.3 2.3
9
6113
62
114
62
17
38
3424
31 31
3669
25
32 62
96
5
22,2
18.5
EB 3963 EN 33
Design and principle of operation
Solenoid valves with NAMUR interface for rotary actuatorsType 3963-xxx8x01: 6/2-way solenoid valve, actuated on one side, KVS 0.16
Screw plug M20x1.5
NAMURfixinglevel
Cable gland M20x1.5
1.4 2.49
2.5 1.5
1.3 2.3
32
61
102
31
2510
252449
39
25
24
67
25
16
5636
38 31
62
10
Types 3963-xxx0x03/-xxx1x03: 3/2-way or 5/2-way solenoid valve, actuated on one side, KVS 1.4
Screw plug M20x1.5
Cable gland M20x1.5
16
5
1
3
4
2
9 9Int
3250.8
12
5.3
72
122
4747
2936
22
38
31
44.4
3461 31
¼"
Port 5 is sealed when the 3/2-way function is used
34 EB 3963 EN
Design and principle of operation
Type 3963-xxx0x07: 3/2-way solenoid valve, actuated on one side, KVS 2.0
Screw plug M20x1.5
Cable gland M20x1.5
NAMUR interface ¼"
61 31
63
G 3/8
G (NPT) ½
G 3/8
66232
26
207
108
66 1221
.5
G (NPT) ¼CapscrewISO 4762,M6x60 with spring washer,DIN 128-A5
Blankingplug¼"
Type 3963-xxx0x04: 3/2-way solenoid valve, actuated on one side, KVS 4.3
Screw plug M20x1.5
Cable gland M20x1.5
61 31
63G (NPT) ½
G (NPT) ½
66245
26
216
118
72 2021
.5
3
5
5
9.
9. Int.
NAMURinterface½"
CapscrewISO 4762,M6x60 with spring washer,DIN 128-A6
Blankingplug¼"
EB 3963 EN 35
Design and principle of operation
Type 3963-xxx1x06: 5/2-way solenoid valve, actuated on one side, KVS 2.9
Screw plug M20x1.5
Cable gland M20x1.5
NAMUR interface
Blankingplug¼"
½"
½"½"
G ¼
61 31
4566
20 ½"
½"
124
4971
7977
.25
169.
5
Ø6
Ø6
5
3
11
9.
36 EB 3963 EN
Design and principle of operation
Types 3963-xxx2x03/-xxx3x03/-xxx5x05: 5/2-way or 5/3-way solenoid valve, actuated on both sides, KVS 1.4
Screw plug M20x1.5
Cable gland M20x1.5
5
1
3
4
2
9 9Int
9
9 Int
5.3
122
122
7261 31 3834
12 44.4
4747
31
¼"
EB 3963 EN 37
Design and principle of operation
Type 3963-xxx2x06: 5/2-way solenoid valve, actuated on both sides, KVS 2.9
Cable gland M20x1.5
61 31
½"
½"
½"
½"
66
Ø6
5
3
1Ø6 64
20Screw plug M20x1.5
NAMUR interface
Blankingplug¼"
Blankingplug¼"
170
77.2
5
32
71
1
½"
G ¼
9.
1
9.
38 EB 3963 EN
Measures for preparation
4 Measures for preparationAfter receiving the shipment, proceed as fol-lows:1. Check the scope of delivery. Compare
the shipment received with the delivery note.
2. Check the shipment for transportation damage. Report any damage to SAMSON and the forwarding agent (refer to delivery note).
4.1 Unpacking
Risk of solenoid valve damage due to for-eign particles entering the valve.Do not remove the packaging if the solenoid valve is to be transported to another location or kept in storage. Do not remove the protec-tive film/protective caps until immediately before mounting the device on the valve.
Before mounting the solenoid valve, proceed as follows:1. Remove the packaging from the solenoid
valve.2. Dispose of the packaging in accordance
with the valid regulations.
4.2 Storage
Risk of solenoid valve damage due to im-proper storage.Observe storage instructions. Contact SAMSON, if need be.
NOTICE!
NOTICE!
Storage instructions − Protect the solenoid valve against exter-nalinfluences(e.g.impact,shocks,vi-bration).
− Do not damage the corrosion protection (coating).
− Protect the solenoid valve against mois-ture and dirt. In damp spaces, prevent condensation. If necessary, use a drying agent or heating.
− Observe storage temperature depending on the permissible ambient temperature (seetechnicaldatainsection 3.2).
− Store the solenoid valve with closed cov-er in airtight packaging.
5 Mounting and start-up
Risk of malfunction due to incorrectly per-formed start-up.Perform start-up following the described sequence.
The procedures to mount, install and start up the solenoid valve are described in the fol-lowing. They must be performed in the pre-scribed sequence.1. Remove the protective caps from the
pneumatic connections.
2. Mount the solenoid valve. Î Section 5.1onward
NOTICE!
EB 3963 EN 39
Mounting and start-up
3. Perform pneumatic installation. Î Section 5.4onward
4. Perform electrical installation. Î Section 5.5onward
5.1 Installation
Risk of personal injury due to parts bursting or the process medium spurting out under high pressure.Before installation, depressurize the relevant plant section.
Risk of degree of protection being rendered ineffective.Only operate the device with the enclosure cover mounted and the exhaust air filters in-stalled.
Installation conditions − Any mounting position may be used. − Thefilterintheenclosurecoverandthe
cable gland must face downward or, in cases where this is not possible, mount them in the horizontal position.
− Onmounting,makesurethat300 mmormore clearance is kept above the enclo-sure cover.
− In cases where mechanical damage of the enclosure cannot be ruled out at the site of installation, mount additional pro-tection to the enclosure.
5.2 Rail mountingTypes 3963-XXXXX11/-XXXXX12
Accessories Order no.
MountingbaseforG-profilerail32
1400-5930
Mountingbasefor35 mmtop-hatrail
1400-5931
Î Mount the solenoid valve on two mount-ingbasesforG-profilerail32accordingtoEN 50035or35 mmtop-hatrailac-cordingtoEN 50022.
G-profilerail32
M3 x 8 DIN 84
38
63
35 mmtop-hatrail
M3 x 8 DIN 84
38
63
Fig. 2: Rail mounting
WARNING!
NOTICE!
40 EB 3963 EN
Mounting and start-up
5.2.1 Wall mountingTypes 3963-XXXXX11/-XXXXX12
Accessories Order no.
Mounting plate 1400-6726
Î Mount the solenoid valve on the mount-ing plate for wall mounting.
6
25
63
82
94
M4 x 8 DIN 912
48
Fig. 3: Wall mounting
Types 3963-XXXXX13/-XXXXX14 Î Insert the screws through the boreholes and fasten the solenoid valve (see dimen-sionsofthesolenoidvalveinsection 3.3.
5.3 Mounting on rotary actua-tors with NAMUR interface
Type 3963-XXXXX0XThe screws required for mounting are includ-ed in the scope of delivery.
Î Before mounting the solenoid valve, check that two O-rings are seated prop-erly.
Î Determine the direction of action of the rotaryactuatorattheconnectingflangewith an M5x10 coded grub screw ac-cordingtoDIN 916.
Î Mount the solenoid valve directly to the rotary actuator using two M5x35 (ISO 4762)screws.
24
32
M5G¼
28
12
Kodier-Gewindestift
Fig. 4: Mounting on rotary actuators with NAMUR interface
5.3.1 Mounting to linear actu-ators with NAMUR rib
Type 3963-XXX002 Î Fasten the solenoid valve using the M8x35(ISO 4762)screwsincludedinthe scope of delivery.
Type 3963-XXX0X0 Î Mount the solenoid valves to linear actu-atorsusingtheadapterplate(Fig. 5).
Coded screw
EB 3963 EN 41
Mounting and start-up
32
14M5
2.3
1.3
12
12 12
25
25
92
30
10
2.31.3
60
15 30
G¼
M8 x 35 DIN 912
Fig. 5: Mounting with adapter plate on linear actuators with NAMUR rib according to IEC 60534-1
A
97
45
Actuator area Connection A Order no.175/240 cm² G ¼/¼ 64 1400-6759
350/355 cm²700/750 cm²
G 3/8/¼ 75 1400-6761G 3 /8/½ 64 1400-6735
Actuator area Connection Order no.1000 cm²1400 cm²–60 mm G ¾/½ 1400-6736
1400 cm²–120/250 mm2800/2 x 2800 cm² G 1/½ 1400-6737
Fig. 6: Mounting to linear actuators using CrNiMo steel pipe fitting
42 EB 3963 EN
Mounting and start-up
When positioners or limit switches are also tobemountedtothelinearactuator(DN 50and smaller), a support (0320-1416) is re-quired.
5.3.2 Mounting to linear actu-ators using CrNiMo steel pipe fitting
Type 3963-xxxxx11 (except for Types 3963xxx1011/-xxx8011)MountingonType 3271or3277ActuatorsaccordingtoFig. 6andtheactuatormount-ing and operating instructions:u EB 8310-x
5.3.3 Mounting on mounting block for Type 3277 Linear Actuator
Type 3963-XXXXX3XTheTypes 3963-XXXXX3XSolenoidValvesare suitable for mounting together with a Type 3730-X,3731-X,3766,3767,378Xor3793PositionertoType 3277LinearAc-tuators(Fig. 7).The screws required for mounting are includ-ed in the scope of delivery.
Î Before mounting, check that the four O-rings are seated properly on the mounting surface.
Î Mount the solenoid valve using two M5x55(ISO 4762)screws.
Î Read the actuator and positioner mount-ing instructions.
5.4 Pneumatic connection
Risk of injury due to high pressure inside de-vice. Prior to performing repair and maintenance work on the device, depressurize the con-necting lines.
The air connections are designed as thread-edholeswithGorNPTthreaddependingon the device version.
Î Run and attach the connecting lines and screw joints according to good profes-sional practice.
Î Check the connecting lines and screw joints for leaks and damage at regular intervals and repair them, if necessary.
Î The KVScoefficientofanupstreampres-sure reducing valve must be at least 1.6 times larger than the KVScoefficientofthe solenoid valve.
Î Protect the exhaust air connections by in-stallingafilterortakingotherappropri-ate precautions to prevent water or dirt from entering them.
5.4.1 Sizing of the connecting line
Î Refertothetableonpage 44fortheminimum required nominal size of the connecting line.
Thespecificationsapplytoaconnectinglineshorterthan2 m.Usealargernominalsizeforlineslongerthan2 m.
WARNING!
EB 3963 EN 43
Mounting and start-up
190
A—B
≥390
*
9029
A B
Typ 3963-XXX0X3 Mounting block, G ¼(orderno. 1400-8817),¼ NPT(orderno.1400-8818)with piping for actuator with "stem extends" fail-safe action
Mounting surface
*Clearance to mount the cover
Fig. 7: Mounting block for Type 3277 Linear Actuator
Type3963-XXX0X3
44 EB 3963 EN
Mounting and start-up
Nominal size (connection length ≤2 m)
KVS0.16 0.32 1.4 2.0
4.3 —
Port
Pressure4 1 and 3 4 9
≥1.4 bar ≥DN 6 ≥DN 8 ≥DN 10
≥DN 4≥2.5 bar≥DN 4
≥DN 6 ≥DN 8
≥6 bar ≥DN 4 ≥DN 6
Types 3963-XXXX0X3/-XXXX014Check whether the nominal size of the con-nectinglineforthesedevicesissufficientlysized as follows:1. Unscrew the threaded stopper from port
9 and mount a pressure gauge.2. The nominal size of the connecting line is
sufficientwhenthepressurereaches1.3 barormoreduringaswitchingpro-cess.
5.4.2 Compressed air quality
Risk of asphyxiation through displacement of air on using nitrogen in unventilated spaces.Discharge the exhaust air of the pilot and booster valves over a common pipe to the at-mosphere.
An operating pressure above the maximum permissible operating pressure will damage the solenoid valve. − Observe the max. operating pressure (see technical data in section 3.2).
DANGER!
NOTICE!
− If necessary, use a pressure reducing valve to restrict the operating pressure.
Risk of malfunction due to failure to comply with required air quality. − Only use supply air that is dry and free of oil and dust. − Read the maintenance instructions for up-stream pressure reducing stations. − Blow through all air pipes and hoses thor-oughly before connecting them.
Operating medium for the booster valveWith internal air supply: − Instrument air free from corrosive
substances or nitrogen − Operatingpressure1.4to6 bar
With external air supply over port 4 and KVS 1.4or4.3:
− Instrument air free from corrosive substances, air containing oil or non-corrosive gases
− Operatingpressure0to10 bar
With external air supply over port 9 − Instrument air free from corrosive
substances, air containing oil or non-corrosive gases
− Operatingpressure0to6 bar
NOTICE!
EB 3963 EN 45
Mounting and start-up
Supply air for the pilot valve − Instrument air free from corrosive
substances or nitrogen − Operatingpressure1.4to6 bar
Compressed air quality according to ISO 8573-1
Particle size and quantity
Oil content Pressure dew point
Class 4 Class 3 Class 3
≤5 µmand1000/m³ ≤1 mg/m³
–20 °C/10 Kbelow the lowest
ambient temperature to be
expected
5.5 Changeover to external air supply over port 9
If the solenoid valve is to be used to switch theoutputsignal(0to6 bar)ofapositioner,the supply air must be routed externally over port 9.
Types 3963-XXXX0X4/-XXXXXX7The supply air in these solenoid valves is fed internallyoverport4,ifnotspecifiedother-wise. To change to an external supply through port 9, proceed as follows:1. Undo the cap screw on the connection
plate and remove plate and gasket .
2. Turn the gasket 90°.Thetipofgasket must rest in the plate cut-out marked '9'.
3. Fasten the plate and gasket to the connection plate.
The gasket of these solenoid valves must be inserted as specified for "Internal supply air over port 4" (see Fig. 10).
Fig. 8: Changeover to external air supply: Types 3963-XXXX0X4/-XXXXXX7
Types 3963-XXXX0X3/-XXXX006The supply air in these solenoid valves is fed internallyoverport1or3,ifnotspecifiedotherwise. To change to an external supply through port 9, proceed as follows:1. Undo the cap screw on the connection
plate and remove plate and gasket .
2. Turn the gasket 180°.Thetipofgas-ket must rest in the plate cut-out marked '9'.
Note
46 EB 3963 EN
Mounting and start-up
3. Fasten the plate and gasket to the connection plate.
The changeover must be performed on both pilot valves for booster valves actuated on both sides.
Fig. 9: Changeover to external air supply: Types 3963-XXXX0X3/-XXXX006
Type 3963 -XXX0002/-XXX0012 -XXX0022/-XXX1011
The supply air in these solenoid valves is fed internallyoverport4,ifnotspecifiedother-wise. To change to an external supply throughport9,proceedasfollows(Fig. 10):1. Undo the four cap screws and remove
the enclosure cover.2. Undo the three hexagon socket head cap
screws and remove the solenoid valve from the connecting plate.
3. Turnthegasket180°.Thetipofgasketmust rest in the device cut-out marked '9'.
4. Fasten the solenoid valve and enclosure cover.
Internal supply over port 4
Int.
External supply over port 9
9
Fig. 10: Mounting the gasket
EB 3963 EN 47
Mounting and start-up
Type 3963 -XXXX001/-XXX0011/ -XXX0X3X/-XXX0101/ -XXX0111/-XXX1001/ -XXX1201/-XXX8001
It is not possible to convert these solenoid valves to accept an external supply air. The gasket, if it exists, must be inserted as speci-fiedfor"Internalsupplyairoverport4"(Fig. 10).
5.6 Exhaust air feedbackType 3963-XXX0013XIn the delivered state, the port 4 of this de-vice is sealed by a blanking plug. If the ex-haust air feedback of actuators with spring return mechanism is to be used, remove the blanking plug and connect port 4 to the ac-tuator'sspringchamberusingaDN 4to10connection line (the sizes depends on the ac-tuator area).
5.7 RestrictionsType 3963-XXXX1/-XXXX2/-XXXX3These devices have one or two restrictions. The logic symbol on the device indicates the restriction function. Use a screwdriver to turn the restriction screws underneath the enclo-sure cover or at the adapter plate to adjust the closing and opening times in a ratio of 1:15.
Type 3963-XXXX1/-XXXX2
Handhilfsbetätigung(optional)
2.3
1.3
Type 3963-XXXX3
4
1.3
Fig. 11: Restriction setting
Manual override (optional)
48 EB 3963 EN
Electrical connection
6 Electrical connection
Risk of electric shock.For electrical installation, observe the rele-vant electrotechnical regulations and the ac-cident prevention regulations that apply in the country of use.
Risk of fatal injury due to the formation of an explosive atmosphere.For installation in hazardous areas, observe the relevant standards that apply in the coun-try of use. − EN 60079-14: 2008 (VDE 0165, Part 1) Explosive Atmospheres – Electrical Installa-tions Design, Selection and Erection.
Incorrect electrical connection will render the explosion protection unsafe. − Adhere to the terminal assignment. − Do not undo the enameled screws in or on the housing. − Do not exceed the maximum permissible values specified in the EC type examina-tion certificates when interconnecting in-trinsically safe electrical equipment (Ui or U0, li or I0, Pi or P0, Ci or C0 and Li or L0).
Selecting cables and wires Î Observe clause 12 of EN 60079-14: 2008 (VDE 0165, Part 1) for installation of the intrinsically safe circuits.
Î Clause 12.2.2.7applieswhenrunningmulti-core cables and wires with more than one intrinsically safe circuit.
Î Preferably use connecting lines with mini-mum0.5 mm²conductorcross-sectionand6to12 mmoutsidediameter.
Î Radial thickness of the insulation of a conductor for common insulating materi-als (e.g. polyethylene): minimum 0.2 mm.
Î Diameter of an individual wire in a fine-strandedconductor: minimum 0.1 mm.
Î Protect the conductor ends against splic-ing, e.g. by using wire-end ferrules.
Î Seal cable entries left unused with screw plugs.
Î For use in ambient temperatures below –20 °C: use metal cable gland.
DANGER!
DANGER!
WARNING!
EB 3963 EN 49
Electrical connection
6.7.1 Switching amplifier ac-cording to EN 60079-25
For operation of the solenoid valve, switch-ingamplifiersmustbeconnectedintheout-put circuit. They must comply with the limit values of the output circuits.
Î Observe the relevant regulations for in-stallation in hazardous areas.
Equipment for use in zone 2In equipment operated according to type of protectionEx nA II(non-sparkingequipment)accordingtoEN 60079-15:2003:
Î Circuits may be connected, interrupted or switched while energized only during installation, maintenance or repair.
6.7.2 Cable entry with cable gland
The electrical connection is made using an M20x1.5 cable gland to the terminals in the enclosureorusingaconnector(seeFig. 12).
Î The cable gland design depends on the ambient temperature range. See techni-caldatainsection 3.2.
Î When two separate cables are used for connection, an additional cable gland can be installed.
6.7.3 Connect the electrical power
Î Connect the electrical power (voltage) as showninFig. 12.
Terminal connection in the enclosure
81 82
+ —
Cable socket (Harting)
8 7 654
23
CablesocketaccordingtoEN 175301-803
+— 23
1
Cable socket M12x1
+—23
14
Fig. 12: Wiring plans
6.1 Degree of protectionDeviceswitharatingofIP 54canbecon-vertedtoaratingofIP 65byexchangingthefilterintheenclosurecover.
50 EB 3963 EN
Operation
6.2 Manual overrideThedevicescanbeoptionallyfittedwithamanual override to allow the device to be manually operated when a nominal signal is not available: − As switch in the enclosure cover − As pushbutton in the enclosure cover − As pushbutton underneath the enclosure
cover
Use devices without manual override for safety circuits.
7 OperationThe solenoid valve is ready for use when mounting and start-up have been completed.
8 Servicing
The solenoid valve was checked by SAMSON before it left the factory. − The product warranty becomes void if ser-vice or repair work not described in these instructions is performed without prior agreement by SAMSON's After-sales Ser-vice department. − Only use original spare parts by SAMSON, which comply with the original specifications (see Data Sheet u T 3963)
8.1 Preparation for return ship-ment
Defective solenoid valves can be returned to SAMSON for repair.Proceed as follows to return devices to SAMSON:1. Decommission the solenoid valve and re-
move it from the valve.2. Fill in the Declaration on Contamination,
which can be downloaded from our website at u www.samson.de>Services>Checklistsforaftersalesservice>Declaration on Contamination.
3. Send the solenoid valve together with the filled-informtoyournearestSAMSONsubsidiary. SAMSON subsidiaries are listed on our website at u www.samson.de.
Note
EB 3963 EN 51
Malfunctions
9 Malfunctions
Contact SAMSON's After-sales Service de-partment for malfunctions not listed in the ta-ble (see section 11.1).
9.1 Emergency actionThe solenoid valve has a safety function. Up-on failure of the supply voltage or air supply, it automatically closes (closed in the de-ener-gized state).The plant operator is responsible for emer-gency action to be taken in the plant.
10 Decommissioning and disas-sembly
Risk of electric shock. − Before performing any work on the device and before opening the device, disconnect the power supply and protect it against un-intentional reconnection. − Only use power interruption devices that are protected against unintentional recon-nection of the power supply.
Risk of bursting in control valve components due to incorrect opening. − Before starting any work on the solenoid valve, depressurize all plant sections con-cerned. − Observe the warnings in the actuator and valve documentation.
NoteDANGER!
DANGER!
Table 2: TroubleshootingMalfunction Possible reasons Recommended action
The solenoid valve does not switch.
Incorrect terminal assignment. Check electrical connection.
Turn turnable gasket to external supply air.
Connect port 9 and supply it with compressed air. Alterna-tively, turn the turnable gasket to internal air supply.
The solenoid valve leaks to the atmosphere.
Gasketslipped. Check that the formed seal and O-rings are correctly seated.
Pilotpressureisinsufficientandan intermediate position of the solenoid valve is reached (air is constantly vented)
Check the pressure line.
Check the pressure line for leakage.
Use a larger cross-section for the pressure line.
52 EB 3963 EN
Appendix
10.1 DecommissioningTo decommission the solenoid valve for dis-assembly, proceed as follows:1. Close the shut-off valves upstream of the
solenoid valve to stop the compressed air fromflowingthroughthesolenoidvalve.
2. Relieve the pipelines completely of pres-sure.
3. Disconnect and lock the power supply.4. Remove the solenoid valve from the pipe-
line
10.2 Disposal Î Observe local, national and internation-al refuse regulations.
Î Do not dispose of components, lubri-cants, and hazardous substances togeth-er with your other household waste.
11 Appendix
11.1 After-sales ServiceContact SAMSON's After-sales Service de-partment for support concerning service or repair work or when malfunctions or defects arise.
E-mailYoucanreachtheAfter-salesServiceDe-partment at aftersalesservice@samson.
Addresses of SAMSON AG and its subsid-iariesTheaddressesofSAMSONAG,itssubsid-iaries, representatives and service facilities worldwide can be found on the SAMSON website or in all SAMSON product catalogs.
Required specificationsPlease submit the following details: − Order number and position number in
the order − Type designation and model number or configurationID
− Other mounted valve accessories (posi-tioner, supply pressure regulator etc.)
− Pressure − Wire cross-section − Actuator type and manufacturer
EB 3963 EN 53
54 EB 3963 EN
EB 3963 EN 55
56 EB 3963 EN
EB 3963 EN 57
58 EB 3963 EN
EB 3963 EN 59
SA
MS
ON
AK
TIE
NG
ES
ELL
SC
HA
FT
Wei
smül
lers
traße
3
6031
4 Fr
ankf
urt a
m M
ain
Tele
fon:
069
400
9-0
· Tel
efax
: 069
400
9-15
07
E-M
ail:
sam
son@
sam
son.
de
Rev
ison
07
EU K
onfo
rmitä
tser
klär
ung
/EU
Dec
lara
tion
of C
onfo
rmity
/ D
écla
ratio
n U
E de
con
form
ité
Die
alle
inig
e V
eran
twor
tung
für d
ie A
usst
ellu
ng d
iese
r Kon
form
itäts
erkl
ärun
g trä
gt d
er H
erst
elle
r/ Th
is d
ecla
ratio
n of
con
form
ity is
issu
ed u
nder
the
sole
resp
onsi
bilit
y of
the
man
ufac
ture
r/ La
pré
sent
e dé
clar
atio
n de
con
form
ité e
st é
tabl
ie s
ous
la s
eule
resp
onsa
bilit
é du
fabr
ican
t. Fü
r das
folg
ende
Pro
dukt
/For
the
follo
win
g pr
oduc
t/N
ous
certi
fions
que
le p
rodu
it
Mag
netv
entil
/ So
leno
id V
alve
/ El
ectr
ovan
ne
Typ/
Type
/Typ
e 39
63
w
ird d
ie K
onfo
rmitä
t mit
den
eins
chlä
gige
n H
arm
onis
ieru
ngsr
echt
svor
schr
iften
der
Uni
on b
estä
tigt/
th
e co
nfor
mity
with
the
rele
vant
Uni
on h
arm
onis
atio
n le
gisl
atio
n is
dec
lare
d w
ith/
est c
onfo
rme
à la
légi
slat
ion
d'ha
rmon
isat
ion
de l'
Uni
on a
pplic
able
sel
on le
s no
rmes
:
EM
C 2
014/
30/E
U
EN 6
1000
-6-2
:200
5, E
N 6
1000
-6-3
:200
7/
A1:2
010,
EN
613
26-1
:201
3
LVD
201
4/35
/EU
EN
610
10-1
:201
0
RoH
S 20
11/6
5/EU
EN
505
81:2
012
Her
stel
ler/
Man
ufac
ture
r/Fa
bric
ant:
SA
MSO
N A
KTIE
NG
ESEL
LSC
HAF
T W
eism
ülle
rstra
ße 3
D
-603
14 F
rank
furt
am M
ain
Deu
tsch
land
/Ger
man
y/Al
lem
agne
Fran
kfur
t/Fr
ancf
ort,
2017
-07-
29
Im N
amen
des
Her
stel
lers
/ On
beha
lf of
the
Man
ufac
ture
r/ Au
nom
du
fabr
ican
t.
Han
no Z
ager
Dirk
Hof
fman
n
Lei
ter Q
ualit
ätss
iche
rung
/Hea
d of
Qua
lity
Man
agm
ent/
Zent
rala
btei
lung
slei
ter/H
ead
of D
epar
tmen
t/Che
f du
dépa
rtem
ent
R
espo
nsab
le d
e l'a
ssur
ance
de
la q
ualit
é
E
ntw
ickl
ungs
orga
nisa
tion/
Dev
elop
men
t Org
aniz
atio
n
ce_3963-0_de_en_fra_rev07.pdf
SA
MS
ON
AK
TIE
NG
ES
ELL
SC
HA
FT
Wei
smül
lers
traße
3
6031
4 Fr
ankf
urt a
m M
ain
Tele
fon:
069
400
9-0
· Tel
efax
: 069
400
9-15
07
E-M
ail:
sam
son@
sam
son.
de
Rev
ison
07
EU K
onfo
rmitä
tser
klär
ung
/EU
Dec
lara
tion
of C
onfo
rmity
/ D
écla
ratio
n U
E de
con
form
ité
Die
alle
inig
e V
eran
twor
tung
für d
ie A
usst
ellu
ng d
iese
r Kon
form
itäts
erkl
ärun
g trä
gt d
er H
erst
elle
r/ Th
is d
ecla
ratio
n of
con
form
ity is
issu
ed u
nder
the
sole
resp
onsi
bilit
y of
the
man
ufac
ture
r/ La
pré
sent
e dé
clar
atio
n de
con
form
ité e
st é
tabl
ie s
ous
la s
eule
resp
onsa
bilit
é du
fabr
ican
t. Fü
r das
folg
ende
Pro
dukt
/For
the
follo
win
g pr
oduc
t/N
ous
certi
fions
que
le p
rodu
it
Mag
netv
entil
/ So
leno
id V
alve
/ El
ectr
ovan
ne
Typ/
Type
/Typ
e 39
63-1
...
en
tspr
eche
nd d
er E
U-B
aum
uste
rprü
fbes
chei
ngun
g P
TB 0
1 AT
EX 2
085
ausg
este
llt v
on d
er/
acco
rdin
g to
the
EU T
ype
Exa
min
atio
n P
TB 0
1 AT
EX 2
085
issu
ed b
y/
étab
li se
lon
le c
ertif
icat
CE
d’es
sais
sur
éch
antil
lons
PTB
01
ATEX
208
5 ém
is p
ar:
Phys
ikal
isch
Tec
hnis
che
Bund
esan
stal
t Bu
ndes
alle
e 10
0 D
-381
16 B
raun
schw
eig
Bena
nnte
Ste
lle/N
otifi
ed B
ody/
Org
anis
me
notif
ié 0
102
wird
die
Kon
form
ität m
it de
n ei
nsch
lägi
gen
Har
mon
isie
rung
srec
htsv
orsc
hrift
en d
er U
nion
bes
tätig
t/
the
conf
orm
ity w
ith th
e re
leva
nt U
nion
har
mon
isat
ion
legi
slat
ion
is d
ecla
red
with
/ es
t con
form
e à
la lé
gisl
atio
n d'
harm
onis
atio
n de
l'U
nion
app
licab
le s
elon
les
norm
es:
EM
C 2
014/
30/E
U
EN 6
1000
-6-2
:200
5, E
N 6
1000
-6-3
:200
7 +A
1:20
11, E
N 6
1326
-1:2
013
Expl
osio
n Pr
otec
tion
94/9
/EC
(bis
/to 2
016-
04-1
9)
Expl
osio
n Pr
otec
tion
2014
/34/
EU (a
b/fro
m 2
016-
04-2
0)
EN 6
0079
-0:2
009,
EN
600
79-1
1:20
12
RoH
S 20
11/6
5/EU
EN
505
81:2
012
Her
stel
ler/
Man
ufac
ture
r/Fa
bric
ant:
SA
MSO
N A
KTIE
NG
ESEL
LSC
HAF
T W
eism
ülle
rstra
ße 3
D
-603
14 F
rank
furt
am M
ain
Deu
tsch
land
/Ger
man
y/Al
lem
agne
Fran
kfur
t/Fr
ancf
ort,
2017
-07-
29
Im N
amen
des
Her
stel
lers
/ On
beha
lf of
the
Man
ufac
ture
r/ Au
nom
du
fabr
ican
t.
Han
no Z
ager
Dirk
Hof
fman
n
Lei
ter Q
ualit
ätss
iche
rung
/Hea
d of
Qua
lity
Man
agm
ent/
Zent
rala
btei
lung
slei
ter/H
ead
of D
epar
tmen
t/Che
f du
dépa
rtem
ent
R
espo
nsab
le d
e l'a
ssur
ance
de
la q
ualit
é
E
ntw
ickl
ungs
orga
nisa
tion/
Dev
elop
men
t Org
aniz
atio
n
ce_3963-1_de_en_fra_rev07.pdf
60 EB 3963 EN
SA
MS
ON
AK
TIE
NG
ES
ELL
SC
HA
FT
Wei
smül
lers
traße
3
6031
4 Fr
ankf
urt a
m M
ain
Tele
fon:
069
400
9-0
· Tel
efax
: 069
400
9-15
07
E-M
ail:
sam
son@
sam
son.
de
Rev
ison
07
EU K
onfo
rmitä
tser
klär
ung
/EU
Dec
lara
tion
of C
onfo
rmity
/ D
écla
ratio
n U
E de
con
form
ité
Die
alle
inig
e V
eran
twor
tung
für d
ie A
usst
ellu
ng d
iese
r Kon
form
itäts
erkl
ärun
g trä
gt d
er H
erst
elle
r/ Th
is d
ecla
ratio
n of
con
form
ity is
issu
ed u
nder
the
sole
resp
onsi
bilit
y of
the
man
ufac
ture
r/ La
pré
sent
e dé
clar
atio
n de
con
form
ité e
st é
tabl
ie s
ous
la s
eule
resp
onsa
bilit
é du
fabr
ican
t. Fü
r das
folg
ende
Pro
dukt
/For
the
follo
win
g pr
oduc
t/N
ous
certi
fions
que
le p
rodu
it
Mag
netv
entil
/ So
leno
id V
alve
/
Typ/
Type
/Typ
e 39
63-8
...
en
tspr
eche
nd d
er E
U-B
aum
uste
rprü
fbes
chei
ngun
g P
TB 0
1 AT
EX 2
086
X a
usge
stel
lt vo
n de
r/ ac
cord
ing
to th
e EU
Typ
e E
xam
inat
ion
PTB
01
ATEX
208
6 X
issu
ed b
y/
étab
li se
lon
le c
ertif
icat
CE
d’es
sais
sur
éch
antil
lons
PTB
01
ATEX
208
6 X
émis
par
:
Phys
ikal
isch
Tec
hnis
che
Bund
esan
stal
t Bu
ndes
alle
e 10
0 D
-381
16 B
raun
schw
eig
Bena
nnte
Ste
lle/N
otifi
ed B
ody/
Org
anis
me
notif
ié 0
102
wird
die
Kon
form
ität m
it de
n ei
nsch
lägi
gen
Har
mon
isie
rung
srec
htsv
orsc
hrift
en d
er U
nion
bes
tätig
t/
the
conf
orm
ity w
ith th
e re
leva
nt U
nion
har
mon
isat
ion
legi
slat
ion
is d
ecla
red
with
/ es
t con
form
e à
la lé
gisl
atio
n d'
harm
onis
atio
n de
l'U
nion
app
licab
le s
elon
les
norm
es:
EM
C 2
014/
30/E
U
EN 6
1000
-6-2
:200
5, E
N 6
1000
-6-3
:200
7 +A
1:20
11, E
N 6
1326
-1:2
013
Expl
osio
n Pr
otec
tion
94/9
/EC
(bis
/to 2
016-
04-1
9)
Expl
osio
n Pr
otec
tion
2014
/34/
EU (a
b/fro
m 2
016-
04-2
0)
EN 6
0079
-0:2
009,
EN
600
79-1
1:20
12,
EN 6
0079
-15:
2010
RoH
S 20
11/6
5/EU
EN
505
81:2
012
Her
stel
ler/
Man
ufac
ture
r/Fa
bric
ant:
SA
MSO
N A
KTIE
NG
ESEL
LSC
HAF
T W
eism
ülle
rstra
ße 3
D
-603
14 F
rank
furt
am M
ain
Deu
tsch
land
/Ger
man
y/Al
lem
agne
Fran
kfur
t/Fr
ancf
ort,
2017
-07-
29
Im N
amen
des
Her
stel
lers
/ On
beha
lf of
the
Man
ufac
ture
r/ Au
nom
du
fabr
ican
t.
Han
no Z
ager
Dirk
Hof
fman
n
Lei
ter Q
ualit
ätss
iche
rung
/Hea
d of
Qua
lity
Man
agm
ent/
Zent
rala
btei
lung
slei
ter/H
ead
of D
epar
tmen
t/Che
f du
dépa
rtem
ent
R
espo
nsab
le d
e l'a
ssur
ance
de
la q
ualit
é
E
ntw
ickl
ungs
orga
nisa
tion/
Dev
elop
men
t Org
aniz
atio
n
ce_3963-8_de_en_fra_rev07.pdf
EB 3963 EN 61
62 EB 3963 EN
EB 3963 EN 63
SAMSON AG · MESS- UND REGELTECHNIKWeismüllerstraße 3 · 60314 Frankfurt am Main, GermanyPhone: +49 69 4009-0 · Fax: +49 69 4009-1507samson@samson.de · www.samson.de EB 3963 EN 20
18-0
4-26
· En
glish