Miracel 19“ Rack
EMC 19“ Rack
ETS Rack
Smaract
Outdoor Cabinet
Street Cabinet
Outdoor Wall Case
ThermalManagement
DC-UPS
RMS
TelecomSpecialCatalogue
TelecomSpecialCatalogue
Outdoor- and Indoor-Solutions
I
K N Ü R R A G
K N Ü R R A G
II
III
K N Ü R R A G
Welcome.
This special catalogue will serve to
help you with your selection and will
pinpoint those products that you
really need to meet your require-
ments in the telecommunications
area.
K N Ü R R A G
IV
19” Racks 19” Enclosures Outdoor Racks
Modular Chassis Bus Systems Active Components
Thermal Management Socket Strips Workstation Systems
Mobile WorkstationsControl Consoles Assembly Furniture
V
K N Ü R R A G
Our customers set the requirements
- and we respond with quality, flexi-
bility, speed and perfect service.
Worldwide, we are recognised as a
particularly reliable partner in the
areas of telecommunications and
data communication, server and net-
work technology, medical technology
and, of course, security, automation
and traffic control technology.
The product diversity and quality
provided by Knürr has been constantly
setting traditionally recognised high
standards for several decades. Our
standardised and customer-specific
technologies are the mirror image
of innovative engineering know-how,
which characterises and provides
the impetus for the markets in which
we operate.
Perfected solutions developed with
mechanical, electronic and thermal
components qualify us as one of the
global market leaders for highly
developed, modular rack and enclo-
sure systems in the indoor and out-
door area, especially for applica-
tions in the telecommunications area.
Workstation systems require uni-
form spatial concepts - complex
technological integration with the
highest functionality available! And
this we guarantee.
Mobile equipment carriers from
Knürr are also instrumental in crea-
ting efficiency and autonomy in the
laboratory, OP area, office or in the
workshop.
The global presence, the innovative
and aesthetic design, a mature
palette of standard products and the
recognised high degree of integration
competence, all supplemented by
outstanding time-to-market results
and above all the unsurpassed
quality, can have but one conclusion:
C O N T E N T
VI
1IndoorSystems
2.3TecorasOutdoor CabinetStrong pointsProducts
2.11TecorasStreet CabinetStrong pointsProductsAccessories
2.23TecorasOutdoor Wall CaseStrong pointsProductsAccessories
2OutdoorSystems
1.3miracel 19” RackStrong pointsProducts
1.12EMC 19” RackDouble panelledStrong pointsProductsAccessories
1.21EMC 19” RackSingle panelledStrong pointsProductsAccessories
1.31ETS RackStrong pointsProducts
1.37smaractStrong pointsProductsAccessories
VII
45.2RMScompactCapabilitiesProductsAccessoriesSensors
Power SupplySystems 6
6.2Standards and RegulationsProtection ratingsEMC InterferencesHeat transferFire behaviour
6.8Index
TechnicalSection3
4.2Rectifier/DC Powerand Backup SystemsStrong pointsTechnical dataProducts
4.10Distribution BoxProducts
ThermalManagement 5System
Monitoring
3.4Indoordart fan unitStrong pointsProductsAccessories
3.10Heat exchangerProducts
3.12Cooling unitProducts
3.15OutdoorTecorasStrong pointsProducts
See also: the current
Network Special Catalogue!Where you will find more products:
• 19” Rack systems
• Free-standing and wall cabinets
• TFT Drawers
• KVM Switches
• UPS Solutions
• RMS-System
• Thermal management
T E L E C O M S P E C I A L C ATA L O G U E
VIII
Rapid service
Express Articles
Fast express delivery service,seamless ordering system,attractive prices and a market–oriented offer - that’s Knürr efficiency!
Every express article that iscorrespondingly identifed inthis catalogue leaves ourEuropean central stores 24hours after your order isreceived: qualitative high-grade, standardised solutions,with which you are alwaysdecisively ahead of the compe-tition.
Our sales offices are also avai-lable for you worldwide, wherecompetent technicians andsales engineers will personal-ly take care of your specialrequirements.Why not use these advantagesto your own benefit.
Express articles
in 24 hours ex plant:
With Knürr you are always
ahead of the competition
IX
T E L E C O M S P E C I A L C ATA L O G U E
Products &Solutions Page X
Capabilities• Design & Prototyping Page XVIII
• Integration Page XXI
T E L E C O M S P E C I A L C ATA L O G U E
X
Mobile NetworksProducts and Solutions
Mobile Networks
Knürr Tecoras product range
Indoor Rack, mobile base
stations, Siemens AG, Germany
Outdoor Cabinet, mobile base
stations, Siemens AG, Germany
Outdoor Cabinet, GSM base station
Telfort, Netherlands
Outdoor Cabinet, GSM base station
Telfort, Netherlands
Outdoor cabinet, Radio Base station
Nortel Networks
6
5
4
3
2
1
TEC002972
TEC200821
Indoor and Outdoor
Base stations for
GSM/UMTS/PMR/WLL
Base stations for mobile net-
works have to provide high
reliability. Tecoras Indoor
racks and Outdoor cabinets
offer an excellent solution for
such applications. Customer
specific requirements can
easily and cost effectively be
implemented due to the plat-
form design.
TEC002983
XI
T E L E C O M S P E C I A L C ATA L O G U E
TEC002954
TEC002965
TEC003166
T E L E C O M S P E C I A L C ATA L O G U E
XII
Outdoor Cabinets
Outdoor Wall Case
ETS rack, DSLAM, Nortel Networks
Broadband, Siemens AG4
3
2
1
Site Support Cabinet (SSC)
for transmission equipment
and DC-backups
Tecoras Outdoor Cabinet with
double walls, thermal manage-
ment system and modular
power supplies including batte-
ries are an excellent base for
Site Support Cabinets. The
modular extendable cabinets
ensure the possibility of future
system expansion.
Repeater
The optionally vented enclosures
for wall and pole mounting,
e.g. antenna and/or repeater
box, are part of the Tecoras
range for telecommunication
solutions.
TEC00010/TEC000871
TEC002482
XIII
T E L E C O M S P E C I A L C ATA L O G U E
Wireline NetworksProducts and Solutions
Wireline Networks
TEC000964
Indoor and Outdoor solutions for access networks
Both miracel Indoor Racks and Tecoras Outdoor
Cabinets are a suitable basis for access network
applications. These usually comprise a DC-UPS
System.
TEC200213
T E L E C O M S P E C I A L C ATA L O G U E
XIV
Telecom Solutions xDSL
With Knürr you will always
find an experienced partner
for complete solutions. Our
Indoor and Outdoor systems
are suitable for broadband
access points.
MIR200611
ISP/ASP
We can provide you with an
optimal rack solution for
colocation systems based on
the following features:
- Based on miracel platform
- Flexible installation space
- Compatible with standard
19“ servers
- Optimal cable management
- Thermal management
- Locking and security
provisions
SON201332
ISP Indoor Rack
ETS Rack assembling
Bavarian radio, tansmission station
Street Cabinet, PrimaCom
Data Center, Techdata, Munich5
4
3
2
1
Wireline NetworksProducts and Solutions
Wireline Networks
XV
T E L E C O M S P E C I A L C ATA L O G U E
CablingKnürr Data Center Competence
Cabling
MIR201825 KON200505
Structured cable
management in rack
systems plays a cen-
tral economic role.(Ask for the brochure!)
Cable TVProducts and Solutions
Cable TV
Tecoras Street Cabinets offer
an excellent mechanical and
thermal protection for CATV
equipment.
DAC201333 TEC800024
T E L E C O M S P E C I A L C ATA L O G U E
XVI
Transport EngineeringProducts and Solutions
Transport Engineering
Railway Solutions
Cost-effective Outdoor Cabinets with thermal manage-
ment systems replace container and concrete shelter
solutions for controlling railway crossings and points.
TEC003001
TEC003002
Outdoor Cabinet HEC for railway crossing and
point control
Street Cabinet, Greek State Railway, OSE Greece
Street Cabinet
Traffic Control Center, Deutsche Bahn AG,
Munich, Germany
4
3
2
1
XVII
T E L E C O M S P E C I A L C ATA L O G U E
Traffic Solutions
The comprehensive configur-
able Tecoras Street Cabinets
range with a whole set of
accessories is ideally suited
for traffic control, tunnel sur-
veillance and toll stations.
Traffic Control TechnologyKnürr Technical Furniture
Traffic Control Technology
TEC002573
MIR201824 KON200504
Complex solutions:
Functional furniture
with the technical
integration of many
active components.
T E L E C O M S P E C I A L C ATA L O G U E
XVIII
Design & PrototypingCapabilities
Design & Prototyping
We cost-effectively integrate the
customer’s corporate identity
into our product platforms
through Knürr’s international
industrial design capabilitiy.
This consequently results in a
customer-unique product.
Complete solution on a platform basis
Customer specific solutions can be cost-effec-
tively implemented in very little time through
tested and certified product platforms. This is
our answer to short Time-to-Market.
XIX
T E L E C O M S P E C I A L C ATA L O G U E
Climate calculation
We ensure that the customer
equipment always operates at
the right temperature. Climatic
calculations and simulations
are verified in our own climatic/
acoustics laboratory.
TEC00279
MIR20128
MIR20129
MIR20130
Solidness calculation
Top technologies and metho-
dologies. e.g. FEM Analysis
are used to cut development
time and cost for complex
testing.
T E L E C O M S P E C I A L C ATA L O G U E
XX
EMC Solutions
High shielding protection against
electromagnetic interferences
is provided by applying an inno-
vative connection technology
and reducing the number of
components, as well as through
careful selection of materials
with highly conductive surfaces.
MIR202142 MIR202163
MIR202134
Structured cabling
System integration and cab-
ling of thermal management
systems, power distribution
and supply, customer equip-
ment and functional testing
are all part of our value-added
service offers.
MEC20086TEC000731 TEC20095
SON20142
Design & PrototypingCapabilities
Design & Prototyping
Dynamic seismic test
In accordance with the FEM
Method, vibrations were simula-
ted in test labs that guarantee
earthquake stability of zone 4
with high loads in compliance
with the Bellcore Standard.
XXI
T E L E C O M S P E C I A L C ATA L O G U E
Dynamic seismic test
Simulation, FEM Method
Dynamic seismic test in accordance
with Bellcore Standard
Static tensile tests
Final check on ETS system racks
in the in-house test facility.
5
4
3
2
1
IntegrationCapabilities
Integration
HEI00429 HEI00430 HEI00431 HEI00432 HEI00433
Level 1
Mechanical assembly
Level 2
Electromechanical assembly
Level 3
Electronic enclosure system
Level 4
Active cards and software
Level 5
Black box & drop ship
TEC201265
Final check
The knowledge and experience
that Knürr can draw on enable
us to provide several levels of
support that reflect the needs
of your company and your
customers:
From Level 1 (assembly of
mechanical components) to
Level 5 (complete turnkey
solutions, starting from design,
through assembly and delivery
to the end user, to follow-on
training and support).
T E L E C O M S P E C I A L C ATA L O G U E
XXII
Power supply dimensioning
and arrangement
Configurable modular Power
Supply Units combined with
additional battery back-up,
monitoring and customised
distribution units provide opti-
mal compliance with system
requirements. AC distribution
units can be adopted according
to international standards and
with country specific outlets.
DI-STRIPKnürr Socket Strips
DI-STRIPYou will find the complete
range in the current
Knürr Network Special
Catalogue.
Request via:
www.knuerr.com
HEI00393
IntegrationCapabilities
Integration
HEI00400
The Knürr Group can help take
your product from the drawing
board to your customer’s faci-
lity, with comprehensive design,
program management, assem-
bly, testing, shipment, training,
and support services.
XXIII
T E L E C O M S P E C I A L C ATA L O G U E
RMS
The Rack Monitoring System
can monitor all environmental
and security events in your net-
work. Sensors permanently
check system conditions and
operational status. Via different
interfaces, the events can be
evaluated remotely, and appro-
piate alarms set.
@Lock
Standard locking systems can
be replaced with electromechan-
ical locking components, allow-
ing simplified administration,
logging and control of access
rights.
Electrical safety
Safety through over-voltage and
lightning protection.
Input box consisting of:
- Monitored over-voltage protection
- Line filter for mains
- Bush-type filter for signal cables
- Supply thermal block HEI00394
MIR20115
VHP00208
RMS20013
Sensors
Safety ensured through early
fire and smoke detection with
special sensors.
IntegrationCapabilities
Integration
T E L E C O M S P E C I A L C ATA L O G U E
XXIV
It is practically irrelevant where you are: if you would like to get to know the Knürr Group’s range of
products and services, there are numerous platforms readily at your disposal. With international repre-
sentation in 32 countries world-wide, domestic companies and overseas subsidiaries, we are
strategically best situated for your requirements.
On the Internet at www.knuerr.com, in addition to all the latest
news, you can find our entire product range including technical
data, press releases and background reports and specialist
articles. Knürr product experts will be able to answer your que-
stions at numerous secialist exhibitions both at home and abro-
ad and will offer comprehensive advice.
Should you wish to realise your workstation system plans with
the Knürr Group, we will happily come and visit you.
Want to get to knowus better?We are always justa click away.
www.knuerr.com
1IndoorSystemsmiracel 19” Rack 1.3 to 1.11
EMC 19” Rack 1.12 to 1.30
ETS Rack 1.31 to 1.36
smaract 1.37 to 1.52
1.1
I N D O O R S Y S T E M S
Indoor Systems
miracel 19” RackStrong Points 1.5
Products 1.9
EMC 19” Rack,Double panelled
Strong Points 1.13
Products 1.16
Accessories 1.17
EMC 19” Rack,Single panelled
Strong Points 1.22
Products 1.26
Accessories 1.27
ETS RackStrong Points 1.32
Products 1.34
smaractStrong Points 1.38
Products 1.40
Accessories 1.42
1.2
I N D O O R S Y S T E M S
See also: the current
Network Special Catalogue!Where you will find more products:
• 19” Rack systems
• Free-standing and wall cabinets
• TFT Drawers
• KVM Switches
• UPS Solutions
• RMS-System
• Thermal management
2miracel19” Rack 1.4 to 1.11
EMC 19” Rack 1.12 to 1.30
1.3
I N D O O R S Y S T E M S
I N D O O R S Y S T E M S
1.4
miracel, the product platform with highflexibility for different applications like ...
... Servers ... Cabling
... power supply ... Mobile communications
MIR
20
17
1
MIR
20
17
3
MIR
20
17
5
TEC
20
06
5
1.5
I N D O O R S Y S T E M S
Front doors
Side panel Ventilation lid
Rear panel
Vertical extrusion (T-slot/mounting holes)
19” Swing frame
Basic rack
Trim extrusion
Side panelMulti-functional strut
Rack bottomcover
Rack plinth, mobile
Rack plinth, stationary
Rack bottom covers
MIR00145
Modularity by availability of different components
I N D O O R S Y S T E M S
1.6
miracel, tested intensively, e.g.Earthquake zone 4, EMC
MIR00227
1.7
I N D O O R S Y S T E M S
B B1 X
[mm] [mm] [mm]
600 535 485
700 635 585
800 735 685
900 835 785
T T1 Y
[mm] [mm] [mm]
600 530 485
800 730 685
900 830 785
1000 930 885
Material- Extruded aluminium- Corner piece, die-castaluminium- Covers, sheet steel, zinc passi-
vated- Doors, sheet steel or with
single safety glass panel,4 mm and 6 mm (double doors)
Installation dimensions in
accordance with IEC 297-3
and IEC 917
- Height: 23 HU / 37 HU / 41 HU /46 HU(1 HU (or 1U) = 44.45 mm)66 Module / 74 module / 82module (1 module = 25 mm)- Width: 482.6 mm (19” design),535 mm (20 module design)
Space solution
- 82% of the surface area asuseable surface for installationand cable routing- Cross-connecting (jumpering)
space, front 123 mm, and 73 mm- Door opening angle 180°
Configuration
- Stationary, on levelling feet- Stationary with plinth- Mobile with plinth and lock
Finish / Colour
- Basic rack, polished- Door trim, black, RAL 9011- Visible cover surfaces, powder-coated, light-grey RAL 7035 ordark-grey RAL 7021
Static load rating
- 5000 N With stationary model- 3000 N With mobile model
Heat transfer
Dissipation power with- Closed cover, up to500 W- Vent lid, up to 700 W
Tests according to the model
- Vibration test in accordancewith MIL-STD 810 E- IP Test in accordance with IEC529- UL Test 1244- NEMA 12 Standard- EMC Shielding attenuation inaccordance with MIL-STD 285(10 MHz - 30 MHz) and VG95 373 part 15 (30 MHZ-1GHz)- Vibrations and shock test inaccordance with ETS 300 019- Seismic test, Bellcore (NEBS)TR-NWT 000063 zone 4- Earth continuity, VDE 0 100 T540
Additional standards and tests onrequest.
Rack suites
To set up a rack suite with anumber of racks (n) you require- all racks (n) minus 1 without
side panels and one rack withside panels - in a rack suite, per connection,
you require one set of rackconnectors
miracel 19” RackTechnical data
Vertical extrusion with mounting holesSteel for 19" racks
19" Server extrusion
Vertical extrusion with T-slotAluminium for 19” structure
7,5
17
32
,5
44
,661
14,8
Vertical extrusion with T-slot
Aluminium, for metric structure, 20 module
MIR00307
MIR00308
MIR00309
MIR20041
MIR00332
I N D O O R S Y S T E M S
1.8
Forward-thinking
Flexibility and security for the
future by integrating 19” andmetric technology.
Modular construction
Includes easy mounting of allnon-standard electronic installa-tions - variable and at integrated
19” or 25 mm increments.
Can be extended at any time
System extensions can be easily
implemented while retaining theIP protection rating.
3
2
1 Cable management
Guaranteed orderly and space-saving cable routing.
Adaption to the installation site,
cable routing selectable with anextensive range of accessory
components.
Flexible ventilation components
Always the best ventilation soluti-
on with the corresponding choiceof accessory components. In this
way, by utilising perforated bot-tom covers, top covers and doors,
the airflow can be specificallyadapted to the installed compo-nents.
5
4
miracelStrong points
MIR201221
TEC000283
MIR005214
MIR004274
MIR001914
MIR200525
MIR004065
MIR001392
1.9
I N D O O R S Y S T E M S
miracelWidth 600 mm and 800 mm with mounting hole extrusion
With fixed 19”-built-in unit on the frontand rear
Installation of chaissis runners and19”-shelves possible
For built-in units in accordance withIEC 297-3
For the installation of- 19” Components on the front and rear- Equipment with maximum width of450 mm- Installation accessories
Jumpering compartment- Front 73 mm
Load rating- 5000 N static
Tests- Earthing according to VDE 0100 part 540- Vibration test according to MIL-STD810 E
Material / Finish- Basic rack, extruded aluminium,polished- Corner piece die-cast aluminium- Multifunctional frames and 19” angularextrusions sheet steel, zinc-plated
Supply schedule1 Basic unit4 19” Sheet steel angular extrusions withmounting holes
2 Multifunctional frames for cable clam-ping and universal assembly options4 Levelling feet (0-25 mm)
How supplied- Assembled
Please noteRack suitesIn a rack suite, per connection you requirea set of suite connectors BN 01.130.935.7
MIR00196
W H D HU/U h d kg Model Order no. UP
591 1196 585 23 1052 440 13 01.130.190.0 1 unit
591 1596 585 32 1452 440 15 01.130.192.0 1 unit
591 1796 585 37 1652 440 16 01.130.193.0 1 unit
591 1996 585 41 1852 440 17 01.130.194.0 1 unit
591 2196 585 46 2052 440 18 01.130.195.0 1 unit
591 1196 785 23 1052 640 14 01.130.280.0 1 unit
591 1596 785 32 1452 640 16 01.130.282.0 1 unit
591 1796 785 37 1652 640 17 01.130.283.0 1 unit
591 1996 785 41 1852 640 18 01.130.284.0 1 unit
591 2196 785 46 2052 640 19 01.130.285.0 1 unit
791 1196 585 23 1052 440 14 01.130.226.0 1 unit
791 1596 585 32 1452 440 16 01.130.228.0 1 unit
791 1796 585 37 1652 440 17 01.130.229.0 1 unit
791 1996 585 41 1852 440 18 01.130.230.0 1 unit
791 2196 585 46 2052 440 19 01.130.231.0 1 unit
791 1196 785 23 1052 640 15 01.130.316.0 1 unit
791 1596 785 32 1452 640 17 01.130.318.0 1 unit
791 1796 785 37 1652 640 18 01.130.319.0 1 unit
791 1996 785 41 1852 640 19 01.130.320.0 1 unit
791 2196 785 46 2052 640 22 01.130.321.0 1 unit
MIR00300
Dimensions in mm: W = Width HU = Standard height unitH = Height UP = Unit of packagingD = Depth kg = Weighth = Installation heightd = Useful depth = Express Article
I N D O O R S Y S T E M S
1.10
miracelWithout front door width 600 mm
With fixed 19”-built-in unit on the frontand rear
Installation of chaissis runners and19”-shelves possible
For built-in units in accordance withIEC 297-3
For the installation of- 19” Components on the front and rear- Equipment with maximum width of450 mm- Installation accessories
Jumpering compartment- Front 73 mm
Load rating- 5000 N static
Tests- Earthing according to VDE 0100 P 540- Vibration test according to MIL-STD810 E
Material / Finish- Basic rack, extruded aluminium- Corner piece die-cast aluminium- Covers and trim extrusions zinc-plated
sheet steel, powder-coated textured- Multifunctional member and 19”-extru-
sions sheet steel, zinc-plated
Colour- Basic unit polished- Visible surface of the cover RAL 7035light grey- Trim extrusions RAL 5008 grey-blue
Supply schedule1 Basic unit4 19” Sheet steel angular extrusions withmounting holes
2 Multifunctional menbers for cable clam-ping and universal assembly options1 Cover, closed1 Rear panel with quick locking2 Side panels with quick locking2 Horizontal decorative extrusions on thefront
2 Vertical decorative extrusions on thefront4 Levelling feet (0-25 mm)
How supplied- Assembled
MIR00466
MIR00540
W H D HU/U h d kg Model Order no. UP
600 1200 600 23 1052 440 42 01.131.068.1 1 unit
600 1600 600 32 1452 440 52 01.131.070.1 1 unit
600 1800 600 37 1652 440 57 01.131.071.1 1 unit
600 2000 600 41 1852 440 62 01.131.072.1 1 unit
600 2200 600 46 2052 440 66 01.131.073.1 1 unit
600 1200 800 23 1052 640 48 01.131.074.1 1 unit
600 1600 800 32 1452 640 58 01.131.076.1 1 unit
600 1800 800 37 1652 640 63 01.131.077.1 1 unit
600 2000 800 41 1852 640 69 01.131.078.1 1 unit
600 2200 800 46 2052 640 75 01.131.079.1 1 unit
MIR00540
Dimensions in mm: W = Width HU = Standard height unitH = Height UP = Unit of packagingD = Depth kg = Weighth = Installation heightd = Useful depth = Express Article
1.11
I N D O O R S Y S T E M S
miracel IP 55With a single-winged glass door width 600 mm
With fixed 19”-built-in unit on the frontand rear
For built-in units in accordance withIEC 297-3
Door opening angle 180°
For the installation of- 19” Components on the front and rear- Equipment with maximum width of450 mm- Installation accessories
Jumpering compartment- Front 73 mm
Load rating- 5000 N static
Degree of protection- IP 55
Tests- Earthing according to VDE 0100 P 540- Vibration test according to MIL-STD810 E- IP test according to DIN 40 050 / IEC 529
Material / Finish- Basic rack, extruded aluminium,polished- Corner pieces, die-cast aluminium,polished- Covers zinc-plated sheet steel,powder-coated textured- Doors, sheet steel, powder-coated
structure, glass infill front door, singlesecurity-glass panel, 4 mm- Multifunctional members and19”-extrusions sheet steel, zinc-plated
Colour- Door trim RAL 9011 black- Visible surface of the cover RAL 7035light grey
Supply schedule1 Basic unit4 19” Sheet steel angular extrusions withmounting holes
2 Multifunctional menbers for cable clam-ping and universal assembly options1 Cover, closed, IP 551 Front door, single-winged, single secu-
rity glass panel, with handle and fixingfor locking cylinders, IP 551 Rear panel with quick locking, IP 552 Side panels with quick locking, IP 551 Base, closed, IP 554 Levelling feet (0-25 mm)
How supplied- Assembled
Please noteRack suitesTo create a rack series with the racknumber n, you require:
(n-1) racks without side panels1 rack with side panels
In a rack suite, per connection you requirea set of suite connectors BN 01.130.935.7
MIR00467
MIR00301
W H D HU/U h d kg Model Order no. UP
600 1200 600 23 1052 440 55 01.132.268.1 1 unit
600 1600 600 32 1452 440 69 01.132.270.1 1 unit
600 1800 600 37 1652 440 75 01.132.271.1 1 unit
600 2000 600 41 1852 440 80 01.132.272.1 1 unit
600 2200 600 46 2052 440 86 01.132.273.1 1 unit
600 1200 800 23 1052 640 65 01.132.274.1 1 unit
600 1600 800 32 1452 640 76 01.132.276.1 1 unit
600 1800 800 37 1652 640 83 01.132.277.1 1 unit
600 2000 800 41 1852 640 90 01.132.278.1 1 unit
600 2200 800 46 2052 640 96 01.132.279.1 1 unit
Dimensions in mm: W = Width HU = Standard height unitH = Height UP = Unit of packagingD = Depth kg = Weighth = Installation heightd = Useful depth = Express Article
I N D O O R S Y S T E M S
1.12
MIR00452
miracel double panelled EMC rack
1.13
I N D O O R S Y S T E M S
MIR004531
MIR004542
MIR004553
Continuous high-grade stainless
steel EMC springs and foam IPseal for protection against elec-tromagnetic radiation and envi-
ronmentals.
Rear connection panel for univer-
sal cable entry mounted with
shortened rear panel or rear
door.
Reliable cable feed with strainrelief.
Simple operation:
Expose braided shield, push
through cable with plug, clampcable with seal.
Perforated top and bottomcovers for thermal managementin racks with simultaneous EMCshielding.
Perforated top and bottom covers
for thermal management in rackswith integrated cable entry andsimultaneous EMC shielding.
6
5
4
3
2
1
miracel 19”-EMC-Rack Double-panelled EMC conceptStrong points
MIR003304
MIR004565
MIR004586
I N D O O R S Y S T E M S
1.14
The diagramm below shows the
EMC design of miracel racks.
EMC shielding is provided by asecond metal case inside the
powder-coated covers.
The reliable, long-life contact
between the covers and the basicrack is guaranteed by a stainless-
steel spring, developed andpatented by Knürr.
The EMC spring permits covers
to be opened and closed ergono-mically with application of mini-
mum closing force while maintai-ning an enduring and reliablecontact.
The ideal combination of materi-
als in EMC through panls, EMCspring and basic rack with lowpotential differences guarantees
long life for contact points.
Extern IP seals also protect the
stainless-steel springs against
aggressive environmental condi-tions.
Technical datamiracel 19”-Rack EMC, double panelled EMC concept
EMC trough panel
High-grade steel spring IP Seal Door hinge
EMC trough panel
Door lock-and-release lever
High-grade steel spring
IP Seal
Quick-release fastener
IP Side panel
1.15
I N D O O R S Y S T E M S
EMC Measurements were carriedout by the army’s Bundeswehr
university, Institute for Electron-ics (Prof. Dr. Schmeer), at
Munich, in a shielded anechoicchamber.
Measurements were carried out
in accordance with the following
standards:
MIL-STD 285(10 kHz - 30 MHz)VG 95373 part 15(30 MHz - 1 GHz)
EMC Test results
miracel, closedWidth 600 mm, depth 600 mm,37 U
2
1
miracel 19” Rack EMC, double panelled EMC concept
Technical data EMC Test results
MIR20196
MIR20197
I N D O O R S Y S T E M S
1.16
miracel 19” Rack, EMC width 600 mmdouble panelled EMC concept
With increased EMC shielding attenuationcompared with standard rack
With fixed 19”-built-in unit on the frontand rear
For built-in units in accordance withIEC 297-3
Door opening angle 180°
For the installation of- 19” Components on the front and rear- Equipment with maximum width of450 mm- Installation accessories
Jumpering compartment- Front 73 mm
Load rating- 5000 N static
Degree of protection- IP 55
Tests- Earthing according to VDE 0100 T 540- Vibration test accordance with MIL-STD810 E- IP test accordance with DIN 40 050 /
IEC 529- EMC in accordance with MIL-STD 285(10 kHz - 30 MHz)- EMC in accordance with VG 95 373 part15 (30 MHz - 1 GHz)
Material / Finish- Basic unit aluminium, crome-plated
yellow- EMC panel zinc-plated- EMC-contact springs stainless steel- Corner piece die-cast aluminium- Covers zinc-plated sheet steel,powder-coated structure- Doors, sheet steel, powder-coated
structure- Multifunctional members and 19” angularextrusions sheet steel, zinc-plated
Colour- Door trim RAL 9011 black- Visible surface of the cover RAL 7035light grey
Supply schedule1 Basic unit EMC4 19” Sheet steel angular extrusions withmounting holes1 Cover EMC, closed1 Front door, single-winged, sheet steel,
with handle and fixing for locking cylin-ders1 Rear panel EMC; sheet steel2 Side panels EMC with quick locking1 Base EMC, closed4 Levelling feet (0-25 mm)
How supplied- Assembled
MIR00449
MIR00301
W H D HU/U h d kg Model Order no. UP
600 1800 600 37 1652 440 122 01.134.053.1 1 unit
600 2000 600 41 1852 440 131 01.134.054.1 1 unit
600 2200 600 46 2052 440 140 01.134.055.1 1 unit
600 1800 800 37 1652 640 133 01.134.059.1 1 unit
600 2000 800 41 1852 640 145 01.134.060.1 1 unit
600 2200 800 46 2052 640 154 01.134.061.1 1 unit
Dimensions in mm: W = Width HU = Standard height unitH = Height UP = Unit of packagingD = Depth kg = Weighth = Installation heightd = Useful depth = Express Article
1.17
I N D O O R S Y S T E M S
MIR00460
MIR00461
MIR00330
miracel EMCConnection baord with flexible cable entry
For EMC miracel with double panelledEMC concept
EMC connection board rear, with cableentry
Compatible EMC sheet steel door shorte-ned or EMC rear panel shortened, alsoavailable
Degree of protection- IP 54
Material / Finish- Cable entry, zinc passivated- Cover, powder coated, textured,
RAL 7035 light-grey
Supply schedule1 Cable entry, complete1 CoverEMC sealsCross-sealingMounting material
How supplied- In batches
W H D HU/U h d kg Model Order no. UP
600 400 01.134.800.1 1 unit
Dimensions in mm: W = Width HU = Standard height unitH = Height UP = Unit of packagingD = Depth kg = Weighth = Installation heightd = Useful depth = Express Article
See also: the current
Network Special Catalogue!Where you will find more products:
• 19” Rack systems
• Free-standing and wall cabinets
• TFT Drawers
• KVM Switches
• UPS Solutions
• RMS-System
• Thermal management
I N D O O R S Y S T E M S
1.18
MIR00464
miracel EMC Sheet steel door, shortenedFor use with an EMC cable inlet, rear
For EMC miracel with double panelledEMC concept
With use of an EMC cable entry, rear side
MaterialSheet steel
Finish- Sheet steel door powder-coated lightgrey, textured RAL 7035 light grey- EMC tray, zinc passivated
Supply schedule1 Sheet steel door1 EMC tray incl. EMC springDesign trimMounting material
How supplied- In batches
W H D HU/U h d kg Model Order no. UP
600 2000 600 1600 01.134.637.1 1 unit
600 2000 800 1600 01.134.638.1 1 unit
600 2200 600 1800 01.134.639.1 1 unit
600 2200 800 1800 01.134.640.1 1 unit
MIR00465
miracel EMC Rear panel, shortenedFor use with an EMC cable inlet, rear
For EMC miracel with double panelledEMC concept
With use of an EMC cable entry, rear side
MaterialSheet steel
Finish- Rear panel: powder-coated, textured
RAL 7035 light grey- EMC tray, zinc passivated
Supply schedule1 Rear panel1 EMC tray incl. EMC springMounting material
How supplied- In batches
W H D HU/U h d kg Model Order no. UP
600 2000 600 1600 01.134.649.1 1 unit
600 2000 800 1600 01.134.651.1 1 unit
600 2200 600 1800 01.134.653.1 1 unit
600 2200 800 1800 01.134.655.1 1 unit
Dimensions in mm: W = Width HU = Standard height unitH = Height UP = Unit of packagingD = Depth kg = Weighth = Installation heightd = Useful depth = Express Article
1.19
I N D O O R S Y S T E M S
MIR00463
miracel EMC tray, perforatedFor bottom / top cover
For EMC miracel with double panelledEMC concept
For ventilation with convection or inconjunction with the ventilation unit
Retention of the EMC shielding
Finish- Zinc passivated
Supply schedule1 EMC Panel bottom / top coverperforated4 Distance bolts for top cover
How supplied- In batches
Please noteThe outer cover must be raised, distancebolts for this are included.
W H D HU/U h d kg Model Order no. UP
600 800 01.134.876.0 1 unit
MIR00456
MIR00459
MIR00458
miracel EMC tray, perforated with cable entryFor bottom / top cover
For EMC miracel with double panelledEMC concept
For entry for cable with plug
Suitable for different cables beside oneanother
For ventilation with convection or inconjunction with the ventilation unit
Retention of the EMC shielding
Finish- Zinc passivated
Supply schedule1 EMC Panel, complete4 Distance bolts for top cover
How supplied- In batches
W H D HU/U h d kg Model Order no. UP
600 800 01.134.921.0 1 unit
I N D O O R S Y S T E M S
1.20
MIR00462
miracel EMCFan installation set
For EMC miracel with double panelledEMC concept
For mounting in the rack upper frame,use only in conjunction with perforatedEMC panel
Fan unit can be retrofitted on 6 fans,cables are pre-configured
Individual fan for upgrading,order no. 03.210.245.9
Includes thermostat (10 - 60° C)
Includes 2 fans (117 m3/h)
Fully wired with 2.5 m power supply leadand plug
Finish- Cover, zinc passivated
Supply schedule1 Airmatic ventilation unit with two fans
and thermostat2 Cover plates2 Mounting brackets
How supplied- In batches
W H D HU/U h d kg Model Order no. UP
600 800 01.134.961.0 1 unit
MIR00457
Dimensions in mm: W = Width HU = Standard height unitH = Height UP = Unit of packagingD = Depth kg = Weighth = Installation heightd = Useful depth = Express Article
TEC20065
1.21
I N D O O R S Y S T E M S
miracel single panelled EMC rack
I N D O O R S Y S T E M S
1.22
Different top cover, door and bot-tom cover variants permit therequired passive air convection tobe attained depending on theprevailing climatic conditions andin accordance with requirements.
Additional ventilation unit is alsoavailable in the top-cover area tomeet enhanced cooling require-ments.
In accordance with IEC 297 for19” installations and IEC 917 formetric installations
In three height variants
(37, 41, 46 U), two depth variants
(400 mm, 600 mm) and one stan-dard with (600 mm).
EMC 19” RackSingle panelled EMC concept (Tecoras indoors)
TEC00045
1.23
I N D O O R S Y S T E M S
EMC Shielding- EMC Shielding comes as stan-
dard with EMC-compatibledesign and the use of suitableseals, combined with IP protec-tion rating to IP 43.
1 EMC suites
- A baying kit permits severalracks to be combined and forma rack suite including cross
wiring of the components andmaintenance of EMC shieldingand IP protection rating.
Cable feed- Accessory components permitan option of top and bottomcable feed.
Ventilation concept
- Perforated bottom and topcovers permit natural convec-tion.
- A fan unit can be mounted inthe top cover outside the instal-lation area to enhance theaction of convection.
- Perforated doors provide anair-intake surface over the enti-re rack height to meet higher
flow-rate requirements.
4
3
2
miracel 19”-EMC Rack, Single-panelled EMC conceptStrong points (Tecoras Indoor)
TEC200951
TEC000282 TEC000293 TEC000724
I N D O O R S Y S T E M S
1.24
miracel 19”-EMC Rack, single panelled EMC concept
Technical data (Tecoras Indoor)
Top Cover
- closed- perforated- closed or perforated, with cable inlet
Rear panel
Side panel
Basic rack
Front door
- closed- perforated- double doors, closed or perforated
Bottom cover
- closed- perforated- closed or perforated with cable inlet
Small and few gaps
Labyrinth effects
Use of modern bendingtechnology
EMC-compatible design
Use of EMC/IP sealings
Use of highly conductive sheetmetal (zink coated)
Technical data
miracel 19” Rack EMC, single panelled EMC concept
TEC00440 Door hingeEMC/IP Seal
Door panel
Frame extrusions Side panel
1.25
I N D O O R S Y S T E M S
EMC Measurements were carriedout by the army’s Bundeswehruniversity, Institute for Electron-ics (Prof. Dr. Schmeer), atMunich, in a shielded anechoicchamber.
Tests were conied out in accor-dance with the following stan-dards:- MIL 285- VG 95373 part 15
Tested rackW 600, D 600, H 2000,closed version
miracel 19”-EMC Rack, single panelled EMC concept
Technical data EMC Test results
TEC20095
TEC00082
Dimensions
Installation height h mm 1652 1852 2052
HE/U 37 41 46
Modul 66 74 82
Overall height H mm 1800 2000 2200
Installation width b mm 482,6 (19”) 482,6 (19”) 482,6 (19”)
alternative Modul 20 20 20
Overall width B mm 600 600 600
Installation depth t mm 235 235 235
alternative mm 435 435 435
Overall depth T mm 400 400 400
alternative mm 600 600 600
I N D O O R S Y S T E M S
1.26
TEC00106
EMC 19” Rack, nominal width 600 mmSingle panelled EMC-concept (Tecoras Indoor)
Suitable for applications with higherrequirements for EMC shielding, e.g. intelecommunications technology
With fixed 19”-built-in unit on the front
For built-in units in accordance withIEC 297-3
Door opening angle 180°
For the installation of- 19” Components on the front- Equipment with maximum construction
width of 450 mm- Installation accessories
Jumpering compartment- Front 73 mm
Load rating- 5000 N static
Degree of protection- IP 43
Heat dissipation- Loss of power up to 500 Watt as
standard
Tests- Earthing in accordance with
VDE 0100 T 540- Vibration test in accordance with
MIL-STD 810 E- Vibration and shock test in accordance
with ETS 300019- IP test according to DIN 40 050 / IEC 529- EMC in accordance with MIL-STD 285(10 kHz - 30 MHz)- EMC in accordance with VG 95 373
Teil 15 (30 MHz - 1 GHz)
Material / Finish- Basic rack, aluminium extrusions,polished- Die-cast aluminium corner pieces- Covers, sheet steel zinc-platedpowder-coated textured- Door, sheet steel zinc-plated, powder-
coated textured- Rear panel, sheet steel, zinc-plated,powder-coated textured
Colour- Visible cover surfaces powder-coated
RAL 7035 light grey
Supply schedule1 Basic rack2 19” Steel extrusions with mountingholes1 Cover, closed1 Front door, single-winged, sheet steel,
with handle and fixing for lockingcylinders1 Rear panel with quick locking2 Side panels, bolted1 Base, closed4 Levelling feet (0-25 mm)
How supplied- Assembled
W H D HU/U h d kg Model Order no. UP
600 1800 400 37 1652 235 52 01.171.009.1 1 unit
600 2000 400 41 1852 235 56 01.171.010.1 1 unit
600 2200 400 46 2052 235 61 01.171.011.1 1 unit
600 1800 600 37 1652 435 60 01.171.021.1 1 unit
600 2000 600 41 1852 435 65 01.171.022.1 1 unit
600 2200 600 46 2052 435 70 01.171.023.1 1 unit
Dimensions in mm: W = Width HU = Standard height unitH = Height UP = Unit of packagingD = Depth kg = Weighth = Installation heightd = Useful depth = Express Article
1.27
I N D O O R S Y S T E M S
TEC00284
Door EMC, perforatedSingle panelled EMC concept (Tecoras Indoor)
Offers air intake surface across the entirerack height with greater air requirementsof the built-in units
Retention of the EMC shielding
Material / Finish- Sheet steel, 1.5 mm heat zinc-plated,
visible surfaces, powder-coated textured
Colour- RAL 7035 light grey
Supply schedule1 EMC door, perforatedMounting hardware
How supplied- Preassembled
W H D HU/U h d kg Model Order no. UP
600 1800 37 01.171.195.1 1 unit
600 2000 41 01.171.196.1 1 unit
600 2200 46 01.171.197.1 1 unit
TEC00283
Door EMC, double wingedSingle panelled EMC concept (Tecoras Indoor)
Lower space requirements in depth whendoor open
Retention of the EMC shielding
Material / Finish- Sheet steel, 1.0 mm heat zinc-plated,powder-coated textured
Colour- RAL 7035 light grey
Supply schedule1 EMC door, double-wingedMounting hardware
How supplied- Preassembled
W H D HU/U h d kg Model Order no. UP
600 1800 37 01.171.207.1 1 unit
600 2000 41 01.171.208.1 1 unit
600 2200 46 01.171.209.1 1 unit
See also: the current
Network Special Catalogue!Where you will find more products:
• 19” Rack systems
• Free-standing and wall cabinets
• TFT Drawers
• KVM-Switches
• UPS Solutions
• RMS-System
• Thermal management
I N D O O R S Y S T E M S
1.28
TEC00287
Top cover EMC, closed with cable entrySingle panelled EMC concept (Tecoras Indoor)
Easily removable panel for individualprocessing
To enter cables from above
Retention of the EMC shielding
Material / Finish- Sheet steel, 1.5 mm heat zinc-plated,
visible surfaces, powder-coated textured- Cable inlet plate zinc-plated
Colour- RAL 7035 light grey
Supply schedule1 EMC cover, closed with cable entryMounting hardware
How supplied- In batches
W H D HU/U h d kg Model Order no. UP
600 400 01.171.107.1 1 unit
600 600 01.171.109.1 1 unit
TEC00286
Top cover EMC, perforatedSingle panelled EMC concept (Tecoras Indoor)
To improve rack cooling by naturalconvection and supported convection bymeans of a fan installation
Retention of the EMC shielding
Material / Finish- Sheet steel, 1.5 mm, heat zinc-plated,
visible surfaces, powder-coated textured
Colour- RAL 7035 light grey
Supply schedule1 EMC cover, perforatedMounting hardware
How supplied- In batches
W H D HU/U h d kg Model Order no. UP
600 400 01.171.087.1 1 unit
600 600 01.171.089.1 1 unit
TEC00288
Top cover, EMC perforated, with cable entrySingle-panelled EMC concept (Tecoras-Indoor)
To improve rack cooling by naturalconvection and supported convection bymeans of a fan installation
Cable entry panel can be easily removeddue to the simple EMC connector systemand can be provided with suitable cutoutsfor cable entries or fitting of EMC filters
Retention of the EMC shielding
Material / Finish- Sheet steel, zinc passivated, powder-
coated, textured, RAL 7035 light-grey- Cable entry: Sheet steel, zinc passivated
Colour- RAL 7035 light grey
Supply schedule1 Top cover, perforated, with cable entryMounting hardware
How supplied- In batches
W H D HU/U h d kg Model Order no. UP
600 400 01.171.117.1 1 unit
600 600 01.171.119.1 1 unit
Dimensions in mm: W = Width HU = Standard height unitH = Height UP = Unit of packagingD = Depth kg = Weighth = Installation heightd = Useful depth = Express Article
1.29
I N D O O R S Y S T E M S
TEC00291
Bottom EMC closed, with cable entrySingle panelled EMC concept (Tecoras-Indoor)
Easily removable board for individualadaptation
Cable entry panel can be easily removeddue to the simple EMC connector systemand can be provided with suitable cutoutsfor cable entries or fitting of EMC filters
Retention of the EMC shielding
Material- Sheet steel, zinc passivated
Supply schedule1 Bottom cover, closed, with cable entryMounting material
How supplied- In batches
W H D HU/U h d kg Model Order no. UP
600 400 01.171.251.0 1 unit
600 600 01.171.253.0 1 unit
TEC00292
Bottom EMC perforated, with cable entrySingle panelled EMC concept (Tecoras-Indoor)
To improve rack cooling by naturalconvection and supported convection bymeans of a fan installation
Cable entry panel can be easily removeddue to the simple EMC connector systemand can be provided with suitable cutoutsfor cable entries or fitting of EMC filters
Retention of the EMC shielding
Prepared for inserting a filter mat underthe bottom cover
Material- Sheet steel, zinc passivated
Supply schedule1 Bottom cover, perforated, with cableentry
Mounting material
How supplied- In batches
W H D HU/U h d kg Model Order no. UP
600 400 01.171.271.0 1 unit
600 600 01.171.273.0 1 unit
TEC00290
Bottom EMC perforatedsingle panelled EMC concept (Tecoras-Indoor)
To improve rack cooling by naturalconvection and supported convection bymeans of a fan installation
Retention of the EMC shielding
Prepared for inserting a filter mat underthe bottom cover
Material- Sheet steel, zinc passivated
Supply schedule1 Bottom cover, perforatedMounting material
How supplied- In batches
W H D HU/U h d kg Model Order no. UP
600 400 01.171.261.0 1 unit
600 600 01.171.263.0 1 unit
Dimensions in mm: W = Width HU = Standard height unitH = Height UP = Unit of packagingD = Depth kg = Weighth = Installation heightd = Useful depth = Express Article
I N D O O R S Y S T E M S
1.30
SMA20058
Replacement filter mats
For perforated bottom covers (Tecoras-Indoor)
For bottom cover with perforation Material- Filedon
Supply schedule1 Set at 5 items
How supplied- In batches
W H D HU/U h d kg Model Order no. UP
600 400 01.171.217.9 1 unit
600 600 01.171.219.9 1 unit
TEC00282
Suite connector, EMCSingle-panelled, EMC concept (Tecoras-Indoor)
For the mechanical, stable connection ofcabinet and rack suites
Expansion of systems in operationpossible from outside
Retention of the EMC shielding values
Retention of the IP protection rating
Supply schedule2 Suite connectors, vertical1 Suite connector, bottom1 Suite connector, topMounting material
How supplied- In batches
W H D HU/U h d kg Model Order no. UP
1800 400 01.171.176.1 1 unit
1800 600 01.171.178.1 1 unit
2000 400 01.171.181.1 1 unit
2000 600 01.171.183.1 1 unit
2200 400 01.171.186.1 1 unit
2200 600 01.171.188.1 1 unit
Dimensions in mm: W = Width HU = Standard height unitH = Height UP = Unit of packagingD = Depth kg = Weighth = Installation heightd = Useful depth = Express Article
See also: the current
Network Special Catalogue!Where you will find more products:
• 19” Rack systems
• Free-standing and wall cabinets
• TFT Drawers
• KVM Switches
• UPS Solutions
• RMS-System
• Thermal management
1ETS Rack
1.32 to 1.36
1.31
I N D O O R S Y S T E M S
I N D O O R S Y S T E M S
1.32
ApprovalThe ETS racks have the DeutscheTelekom certificate of approval.
Ventilation
The rack construction design
favours natural convection.
Flexibility
- The height-adjustable wallmounting allows flexiblemounting for the rack to matchsurrounding environments.
- Optional cable entry over grid
flooring or hollow flooring.
1
ETS RackStrong points
TEC00280
Rear panel
Cable mounting rails
Cover closed with cable inlet
Basic rack
Front door
- closed- perforated
1.33
I N D O O R S Y S T E M S
TEC00083
TEC000301
The ETS system rack complies withETS 300 119-3 (EuropeanTelecommunications Standard) andthe technical supply conditions5805-3158 of Deutsche Telekom forinstallation in accordance with IEC917 and IEC 297.
Material- Basic rack, sheet steel 2.0 mm- Doors and rear panel,
sheet steel 1.0 mm- Roof, sheet steel 1.5 mm- Plinth trim, sheet steel
2.0 mm
Finish- Vertical posts and mounting
brackets for cable grid connec-tion, zinc passivated andchrome-plated (Fe/Zn 6-12 cB)- Basic racks, doors, rear panel
and plinth trim, powder-coatedRAL 7032, pebble grey textured
ConfigurationStationary, on levelling feet
Static loads- Maximum load with uniformdistribution: 2300 N- Maximum permissible load with
cable runway and cable: 1900 N- Maximum compressive load on
the floor exerted by feet:490 N/cm2
Tecoras ETS RackTechnical data
ETS Rack Dimensioning
W H D CW w h d
600 2200 300 500 515 2052 240
I N D O O R S Y S T E M S
1.34
ETS Rack H 2200, d 240 weldedFor installations in accordance with IEC 917 and IEC 297
ETS System rack complies with ETS300 119-3 (European TelecommunicationsStandard) and the technical supply conditions5805-3158 of Deutsche Telekom for installati-ons in accordance with IEC 917 and IEC 297.
Standard features
- Welded version, height 2200 mmconsists of:1 Basic rack
consisting of 2 side panels and4 bracing struts
2 Levelling feet4 Cable restraints2 ESD Jacks
30 Caged nuts M6 (pack)
W H D HU/U h d Model Order no. UP
600 2200 300 82M 2050 240 ETS Rack 01.100.001.3 1 unit
Front door closed 01.100.010.3 1 unit
Front door perforated 01.100.011.3 1 unit
Rear panet 01.100.021.3 1 unit
Root, closed 01.100.031.3 1 unit
Plinth trim with option for socket 01.100.053.3 1 unit
ETS Rack H 2200, d 240 flat packedFor installations in accordance with IEC 917 and IEC 297
Standard features
- Flat pack version, height 2200 mm,for mounting on-site, consisting of:2 Side panels4 Bracing struts2 Levelling feet4 Cable restraints2 ESD Jacks2 L Rails with cable holder for
connection to the cable gridMounting material30 Caged nuts M6 (pack)
W H D HU/U h d Model Order no. UP
600 2200 300 82M 2050 240 ETS Rack 01.100.003.3 1 unit
ETS Rack H 2200, d 170 weldedFor installations in accordance with IEC 917 and IEC 297
Standard features
- Welded version, height 2200 mm withrecessed side panels and recessedmounting level for 170 mm installationdepth consisting of:1 Basic rack
consisting of 2 side panels and4 bracing struts8 Cable covers2 Levelling feet4 Cable restraints2 ESD Jacks2 L Rails with cable holder for
connection to the cable grid30 Caged nuts M6 (pack)
TEC00090
W H D HU/U h d Model Order no. UP
600 2200 300 82M 2050 170 ETS Rack 01.100.004.3 1 unit
TEC00251
1.35
I N D O O R S Y S T E M S
TEC00251
ETS Rack H 2200, d 170, earth quake proofedFor installations in accordance with IEC 917 and IEC 297
Standard features
- Welded version, height 2200 mm withrecessed side panels and recessedmounting level for 170 mm installationdepth, earthquake-proof in accordancewith Telcordia GR-63-CORE zone 4,consisting of:1 Basic rack
consisting of 1 bottom cover, 1 topcover and 2 side panels8 Cable covers4 Cable restraints2 ESD Jacks2 L Rails with cable holder for
connection to the cable grid30 Caged nuts M6 (pack)
W H D HU/U h d Model Order no. UP
600 2200 300 82M 2050 170 ETS Rack 01.100.005.3 1 unit
ETS Rack H 1800, d 240, weldedFor installations in accordance with IEC 917 and IEC 297
Standard features
- Welded version, height 1800 mmconsisting of:1 Basic rack
consisting of 2 side panels and4 bracing struts
2 Levelling feet3 Cable restraints2 ESD Jacks2 L Rails with cable holder for
connection to the cable grid30 Caged nuts M6 (pack)
W H D HU/U h d Model Order no. UP
600 2200 300 66M 1650 240 ETS Rack 01.100.006.3 1 unit
ETS Rack H 2200, d 480, weldedFor installations in accordance with IEC 917 and IEC 297
Standard features
- Welded version, height 2200 mmand depth 600 mm consisting of:1 Basic rack
consisting of 2 side panels and4 bracing struts4 Levelling feet4 Cable restraints2 ESD Jacks2 L Rails with cable holder for
connection to the cable grid30 Caged nuts M6 (pack)
W H D HU/U h d Model Order no. UP
600 2200 600 82M 2050 480 ETS Rack 01.100.007.3 1 unit
I N D O O R S Y S T E M S
1.36
ETS Rack H 2200, d 240, weldedFor 23” Installations
Standard features- Welded version, height 2200 mmand depth 300 mm consisting of:1 Basic rackconsisting of 2 side panels and4 bracing struts
4 Levelling feet
4 Cable restraints
2 ESD Jacks
2 L Rails with cable holder for
connection to the cable grid30 Caged nuts M6 (pack)
W H D HU/U h d Model Order no. UP
600 2200 300 82M 2050 240 ETS Rack 01.100.008.3 1 unit
See also: the current
Network Special Catalogue!Where you will find more products:
• 19” Rack systems
• Free-standing and wall cabinets
• TFT Drawers
• KVM Switches
• UPS Solutions
• RMS-System
• Thermal management
2smaractCompact Rack 1.38 to 1.52
1.37
I N D O O R S Y S T E M S
I N D O O R S Y S T E M S
1.38
Access
Access from all sides is atime-saving factor with, forexample, system integrationor maintanence.
First-class design
Low weight with innovative frameconcept. Nevertheless, highstability with new triangularextrusions.
Grows with requirements
Easy expansion with stackablecomponents.
Cable management
No matter how complex, Knürrcreates the right solutions.
EMC and IPmodelsThe compact rack can be equip-ped at any time to meet IP orEMC standards.(Also in combination with IP/EMCmodel)
Forward-thinking
Flexibility with the integration of19” technology.Choice of 6 heights from 9HU to24 HU.
6
5
4
3
2
1
smaractStrong points
SMA200053
SMA200044
SMA200171
SMA200062
SMA200565
SMA200466
1.39
I N D O O R S Y S T E M S
Material- Extruded aluminium- Corner connector, die-castaluminium
- Covers, sheet steel- Doors, sheet steel or with
single security glass panel,opening angle, 180°
19” Installations in accordancewith IEC 297-3
- Height: 9 HU to 24 HU1HU (or 1U) = 44.45 mm
- Width: 482.6 mm (19”)
Models- IP 20- IP 54- EMC
Space provided
- 82% of the basic surface asuseable surface for installationand cable routing
Configuration
- Stationary, on levelling feet- Mobile on castors with lock
Finish- Basic rack, polished- Covers, powder-coated, RAL
7035 light-grey, textured
Static load- 2000 N With stationary model
How supplied
- Fully assembled
Tests in line with model
- Safety in accordance with EN50298 and EN 60950
- Protective conductor / earth inaccordance withDIN VDE 0701-1
- Vibration test in accordancewith MIL-STD 810 E
- Vibration and shock test inaccordance with DIN EN300019-2-2
- IP Test in accordance with DINEN 60529
- EMC Shielding attenuation inaccordance with IEEE-STD-299and VG 95 373 part 15 (30 MHz -1 GHz)
- Plastic components comply withUL 94-VO
smaract 19” Compact Rack, In Accordance with IEC 297
Technical data
I N D O O R S Y S T E M S
1.40
smaract 19” Compact RackWith glass door
W H D HU/U h d kg Model Order no. UP
478 600 9 16 Type 1 02.110.007.1 1 unit
612 600 12 20 Type 1 02.110.012.1 1 unit
745 600 15 24 Type 1 02.110.017.1 1 unit
879 600 18 28 Type 1 02.110.022.1 1 unit
1012 600 21 32 Type 1 02.110.027.1 1 unit
1145 600 24 36 Type 1 02.110.032.1 1 unit
478 800 9 19 Type 1 02.110.009.1 1 unit
612 800 12 23 Type 1 02.110.014.1 1 unit
745 800 15 27 Type 1 02.110.019.1 1 unit
879 800 18 31 Type 1 02.110.024.1 1 unit
1012 800 21 35 Type 1 02.110.029.1 1 unit
1145 800 24 39 Type 1 02.110.034.1 1 unit
478 600 9 16 Type 2 02.110.057.1 1 unit
612 600 12 20 Type 2 02.110.062.1 1 unit
745 600 15 24 Type 2 02.110.067.1 1 unit
879 600 18 28 Type 2 02.110.072.1 1 unit
1012 600 21 32 Type 2 02.110.077.1 1 unit
1145 600 24 36 Type 2 02.110.082.1 1 unit
478 800 9 19 Type 2 02.110.059.1 1 unit
612 800 12 23 Type 2 02.110.064.1 1 unit
745 800 15 27 Type 2 02.110.069.1 1 unit
879 800 18 31 Type 2 02.110.074.1 1 unit
1012 800 21 35 Type 2 02.110.079.1 1 unit
1145 800 24 39 Type 2 02.110.084.1 1 unit
SMA20024
- For installations in accordance withIEC 297-3- Removable covers
VariantsType 1- With 19”-T-slot extrusionType 2- With 19”-mounting holes extrusion
Load rating- 2000 N static
Material- Basic rack: extruded aluminium- Covers: sheet steel
Finish- Basic rack: polished- Covers: powder-coated textured
Colour- RAL 7035 light grey
Supply scheduleType 11 Basic rack2 Side panels, closed, both sides, hinged1 Top cover, closed1 Glass front door1 Rear door with cable entry, lockable,prepared for ventilation unit
2 19” Aluminium vertical extrusions, atthe front with T-slot1 Earthing set4 Levelling feetType 21 Basic rack2 Side panels, closed, both sides, hinged1 Top cover, closed1 Glass front door1 Rear door with cable entry, lockable,prepared for ventilation unit
2 19” Sheet steel vertical extrusion, at thefront with mounting holes1 Earthing set4 Levelling feet
How supplied- Assembled
SMA20026
Dimensions in mm: W = WIdth HU = Standard height unitH = Height UP = Unit of packagingD = Depth kg = Weighth = Installation height = Express Articled = Useful depth
1.41
I N D O O R S Y S T E M S
smaract 19” Compact RackEnclosure without door
- For built-in units in accordance withIEC 297-3
- Removable covers
Load rating- 2000 N static
Material- Basic rack: extruded aluminium- Covers: sheet steel
Finish- Basic rack: polished- Covers: powder-coated textured
Colour- RAL 7035 light grey
Supply schedule1 Basic rack2 Side panels, closed, both sides, hinged1 Cover, closed1 Panel frame, at the front1 Rear door with cable entry, lockable,
prepared for ventilation unit2 19” Aluminium vertical extrusions, at
the front, with T-slot1 Earthing set4 Levelling feet
How supplied- Assembled
W H D HU/U h d kg Model Order no. UP
478 600 9 16 02.110.107.1 1 unit
745 600 15 24 02.110.117.1 1 unit
1012 600 21 28 02.110.127.1 1 unit
478 800 9 19 02.110.109.1 1 unit
745 800 15 25 02.110.119.1 1 unit
1012 800 21 31 02.110.129.1 1 unit
SMA20025
SMA20027
SMA20042
See also: the current
Network Special Catalogue!Where you will find more products:
• 19” Rack systems
• Free-standing and wall cabinets
• TFT Drawers
• KVM-Switches
• UPS Solutions
• RMS-System
• Thermal management
I N D O O R S Y S T E M S
1.42
smaract 19” Sheet Steel Extrusion with mounting holes
- For installation at the front and rear
Material / Finish- 19” Extrusions: sheet steel zinc-plated- Mounting bracket: sheet steel
zinc-plated
Supply schedule2 19” Extrusions with mounting holes
4 Mounting bracket
Mounting hardware
How supplied- Flat-packed kit
SMA20104
SMA20106
W H D HU/U h d kg Model Order no. UP
9 02.111.156.9 1 unit
12 02.111.157.9 1 unit
15 02.111.158.9 1 unit
18 02.111.159.9 1 unit
21 02.111.160.9 1 unit
24 02.111.161.9 1 unit
smaract 19” Aluminium Extrusions with T-Slot
- For installation at the front and rear
Material / Finish- 19” Extrusions: extruded aluminium
polished- Mounting bracket: sheet steel
zinc-plated
Supply schedule2 19” Extrusions with T-Slot,
includes increment slide4 Mounting brackets
Mounting hardware
How supplied- Flat-packed kit
SMA20103
SMA20105
W H D HU/U h d kg Model Order no. UP
9 02.111.146.9 1 unit
12 02.111.147.9 1 unit
15 02.111.148.9 1 unit
18 02.111.149.9 1 unit
21 02.111.150.9 1 unit
24 02.111.151.9 1 unit
1.43
I N D O O R S Y S T E M S
smaract Cover / base closed
Material / Finish- Sheet steel, powder-coated texture
Colour- RAL 7035 light grey
Supply schedule1 Base closedMounting hardware
How supplied- Flat-packed kit
W H D HU/U h d kg Model Order no. UP
600 02.111.052.1 1 unit
800 02.111.054.1 1 unitSMA20028
smaract Perforated base with filter mat
- For cooling using air convection Material / Finish- Base: sheet steel powder-coated texture- Filter mat: filedon
Colour- RAL 7035 light grey
Supply schedule1 Perforated base with filter matMounting Hardware
How supplied- Flat-packed kit
W H D HU/U h d kg Model Order no. UP
600 02.111.062.9 1 unit
800 02.111.064.9 1 unit
SMA20029
smaract Replacement filter mat
- For use in connection with perforated base Material / FinishFiledon
Supply schedule5 Replacement filter mats
How supplied- Flat-packed kit
SMA20058 W H D HU/U h d kg Model Order no. UP
600 02.111.068.9 1 unit
800 02.111.069.9 1 unit
I N D O O R S Y S T E M S
1.44
smaract Rear door closed
Material / Finish- Sheet steel, powder-coated texture
Colour- RAL 7035 light grey
Supply schedule1 Rear door closedMounting hardware
How supplied- Flat-packed kit
W H D HU/U h d kg Model Order no. UP
9 02.111.076.1 1 unit
12 02.111.077.1 1 unit
15 02.111.078.1 1 unit
18 02.111.079.1 1 unit
21 02.111.080.1 1 unit
24 02.111.081.1 1 unit
SMA20031
smaract Ventilation unit
- Easy add-on on the rear panel- With two axial fans- With thermostat
Material / Finish- Sheet steel zinc-plated
Supply schedule1 Ventilation unit ready for connection
with thermostatMounting hardware
How supplied- Preassembled
W H D HU/U h d Model Order no. UP
02.111.180.9 1 unitSMA20033
smaract Twin castor
- Height 50 mm
Load rating- 500 N per castor- 1500 N max. statical total load per rack
Material- Polyamide
Colour- RAL 9011 graphite black
Supply schedule2 Twin castor2 Lockable castors
How supplied- Flat-packed kit
W H D HU/U h d kg Model Order no. UP
9 02.111.175.9 1 unitSMA20034
1.45
I N D O O R S Y S T E M S
SMA20091
SMA20095
smaract Plinth
- Stationary
- Cable entry possible on all sides
- Trims front and rear with vent slots andinsert option for filter mats
Material / Finish- Sheet steel, powder-coated texture
Colour- RAL 7035 light grey
Supply schedule4 Plinth corners2 Trims, closed2 Trims, with vent slotsMounting material
How supplied- Flat-packed kit
W H D HU/U h d kg Model Order no. UP
600 100 600 02.111.201.1 1 unit
600 100 800 02.111.203.1 1 unit
SMA20098
smaract Plinth trim with cable entry
- For use in conjunction with the plinth
Material / Finish- Sheet steel, powder-coated texture
Colour- RAL 7035 light grey
Supply schedule1 Trim with cable entry1 Brush stripMounting material
How supplied- Flat-packed kit
W H D HU/U h d kg Model Order no. UP
600 02.111.206.9 1 unit
MIR20140
smaract Filter mat for plinth trim
- For installation in the plinth trim on thefront and rear
Material / Finish- Filedon
Supply schedule2 Filter mats
How supplied- Flat-packed kit
W H D HU/U h d kg Model Order no. UP
600 01.130.532.9 1 unit
I N D O O R S Y S T E M S
1.46
smaract Stacking Set
- Fixed connection to stack the small racks
Material / Finish- Steel cold rolled zinc-plated
Supply schedule4 Stack elementsMounting hardware
How supplied- Flat-packed kit
SMA20035
W H D HU/U h d kg Model Order no. UP
02.111.171.9 1 set
120
30
90
60
°
MIR00319
Mounting Set, Floor Fixing
- For fixing the rack to the floor, e.g. withsuitable dowels and screws set in concerte
Material- Sheet steel 3 mm
Finish- Zinc passivated
Supply schedule4 Clamping plate
How supplied- Flat-packed kit
W H D HU/U h d kg Model Order no. UP
01.130.934.7 1 set
smaract Eyebolt Set
- For hanging up crane hooks
Load rating- 1900 N per ring screw
Material- Tool steel, forged
Supply schedule4 Jack rings M8
How supplied- Flat-packed kit
W H D HU/U h d kg Model Order no. UP
M8 01.243.440.9 1 unit
MEC00074
smaract Wall-Mounting Bracket
W H D HU/U h d kg Model Order no. UP
600 02.111.220.9 1 set
Load rating- 500 N static
Material / Finish- Steel sheet, powder-coated, textured
Colour- RAL 7035 light grey
Supply schedule2 Wall-mounting bracketsDrill hole templateMounting material
How supplied- In batches
SMA20085
SMA20094
1.47
I N D O O R S Y S T E M S
smaract 19” Enclosure, EMC, with sheet steel door
- For installation in accordance withIEC 297-3
- Removable covers
Load rating- 2000 N static
Material- Basic rack: extruded aluminium- Covers: sheet steel- EMC spring: stainless steel
Finish- Basic rack: polished- Covers: powder-coated textured
Colour
- RAL 7035 light grey
Supply schedule1 Basic rack2 Side panels, EMC, closed, hinged onboth sides
1 Top cover, EMC, closed1 Bottom cover, EMC, closed1 Front door, EMC, closed1 Rear door, EMC, closed, screwed2 19” Aluminium vertical extrusions,
front, with T-Slot, incl. increment slide1 Earthing set4 Levelling feet
How supplied- Assembled
W H D HU/U h d kg Model Order no. UP
600 879 600 18 36 02.110.322.1 1 unit
600 879 800 18 40 02.110.324.1 1 unit
SMA20065
SMA20059 TEC20098
EMC measurements were carried out byPlem Electronic GmbH, Frontenhausen
Tests were conied out in accordance withthe following standard: VG 95373 part 15
Tested rackW600, D 600, H 1150, closed version
I N D O O R S Y S T E M S
1.48
smaract Connection panel EMC, closed
- EMC shielded- Screwed
Material- Cover: sheet steel- EMC spring: stainless steel
Finish- Powder-coated textured
Colour
- RAL 7035 light grey
Supply schedule1 Connection panel2 BracketsMounting hardware
How supplied- Flat-packed kit
W H D HU/U h d kg Model Order no. UP
600 131,3 3 02.111.351.1 1 set
SMA20148
smaract Connection panel EMC, with cable entry
- EMC shielded- Screwed
Material- Cover: sheet steel- EMC spring: stainless steel- EMC sealing extrusion: rubber with
stainless steel mash
Finish- Powder-coated textured
Colour
- RAL 7035 light grey
Supply schedule1 Connection panel with cable entry2 BracketsMounting hardware
How supplied- Flat-packed kit
W H D HU/U h d kg Model Order no. UP
600 131,3 3 02.111.361.1 1 set
SMA20145
SMA20137
SMA20137
1.49
I N D O O R S Y S T E M S
smaract Connection panel EMC, for fan unit
- EMC shielded- Screwed
Material- Cover: sheet steel- EMC spring: stainless steel
Finish- Powder-coated textured
Colour
- RAL 7035 light grey
Supply schedule1 Connection panel for fan unit2 BracketsMounting hardware
How supplied- Flat-packed kit
NoteFitting ventilation unit: 02.111.180.9
W H D HU/U h d kg Model Order no. UP
600 264,6 6 02.111.372.1 1 set
SMA20150
smaract Rear panel EMC, closed
- EMC shielded- Screwed
Material- Cover: sheet steel- EMC spring: stainless steel
Finish- Powder-coated textured
Colour
- RAL 7035 light grey
Supply schedule1 Connection panel for fan unit2 BracketsMounting hardware
How supplied- Flat-packed kit
W H D HU/U h d kg Model Order no. UP
600 556,3 12 02.111.354.1 1 set
600 689,6 15 02.111.355.1 1 set
SMA20152
SMA20137
SMA20135
I N D O O R S Y S T E M S
1.50
smaract 19” Enclosure IP54, with glass door
- For installations in accordance withIEC 297-3
- Removable covers
Load rating- 2000 N static
Degree of protection- IP 54
Material- Basic rack: extruded aluminium- Covers: sheet steel- Foam sealing: polyurethane
Finish- Basic rack: polished- Covers: powder-coated textured
Colour- RAL 7035 light grey
Supply schedule1 Basic rack2 Side panels, IP 54, closed, hinged onboth sides
1 Top cover, IP 54, closed1 Bottom cover, IP 54, closed1 Glass front door IP 541 Rear door, IP 54, closed, screwed2 19” Aluminium vertical extrusions,
front, with T-Slot, incl. increment slide1 Earthing set4 Levelling feet
How supplied- Assembled
SMA20062W H D HU/U h d kg Model Order no. UP
600 612 600 12 28 02.110.212.1 1 unit
600 879 600 18 36 02.110.222.1 1 unit
600 1146 600 24 44 02.110.232.1 1 unit
600 612 800 12 32 02.110.214.1 1 unit
600 879 800 18 40 02.110.224.1 1 unit
600 1146 800 24 48 02.110.234.1 1 unit
SMA20108
See also: the current
Network Special Catalogue!Where you will find more products:
• 19” Rack systems
• Free-standing and wall cabinets
• TFT Drawers
• KVM Switches
• UPS Solutions
• RMS-System
• Thermal management
1.51
I N D O O R S Y S T E M S
smaract Connection panel IP 54, closed
- IP 54 protection rating- Screwed
Material- Cover: sheet steel- Foam sealing: polyurethane
Finish- Powder-coated textured
Colour
- RAL 7035 light grey
Supply schedule1 Connection panel2 BracketsMounting hardware
How supplied- Flat-packed kit
W H D HU/U h d kg Model Order no. UP
600 131,3 3 02.111.301.1 1 set
SMA20148
smaract Connection panel IP 54, with cable entry
- Possible seal up: IP 54- Screwed
Material- Cover: sheet steel- Foam sealing: polyurethane- Sealing extrusion: foam-rubber seal
Finish- Powder-coated textured
Colour
- RAL 7035 light grey
Supply schedule1 Connection panel with cable entry2 BracketsMounting hardware
How supplied- Flat-packed kit
W H D HU/U h d kg Model Order no. UP
600 131,3 3 02.111.311.1 1 set
SMA20139
SMA20138
SMA20138
I N D O O R S Y S T E M S
1.52
smaract Connection panel IP 54, for fan unit
- IP 54 protection rating- Screwed
Material- Covers: sheet steel- Foam sealing: polyurethane- Exit filter: ABS plastic, UL94 V-0
Finish- Powder-coated textured
Colour
- RAL 7035 light grey
Supply schedule1 Connection panel for fan unit2 BracketsMounting hardware
How supplied- Flat-packed kit
NoteFitting ventilation unit: 02.111.180.9
W H D HU/U h d kg Model Order no. UP
600 264,6 6 02.111.322.1 1 set
SMA20143
smaract Rear panel IP 54, closed
- IP 54 protection rating- Screwed
Material- Covers: sheet steel- Foam sealing: polyurethane
Finish- Powder-coated textured
Colour
- RAL 7035 light grey
Supply schedule1 Connection panel for fan unit2 BracketsMounting hardware
How supplied- Flat-packed kit
W H D HU/U h d kg Model Order no. UP
600 289,6 6 02.111.302.1 1 set
600 422,9 9 02.111.303.1 1 set
600 556,3 12 02.111.304.1 1 set
600 689,6 15 02.111.305.1 1 set
600 823 18 02.111.306.1 1 set
600 956,3 21 02.111.307.1 1 set
SMA20141
SMA20138
SMA20136
2OutdoorSystemsOutdoor Cabinet 2.3 to 2.9
Street Cabinet 2.11 to 2.21
Outdoor Wall Case 2.23 to 2.28
2.1
O U T D O O R S Y S T E M S
Outdoor Systems
Tecoras
Outdoor CabinetStrong Points 2.4
Products 2.7
Tecoras
Street CabinetStrong Points 2.12
Products 2.15
AccessoriesVertical Extrusion 2.18
Battery Tray 2.18
Depth Strut 2.18
Compact Cabinet Lamp 2.19
Door Contact Switch 2.19
Cable Entry 2.20
Plinths 2.20
Mounting Panel 2.21
Tecoras
Outdoor Wall CaseStrong Points 2.24
Products 2.25
AccessoriesBattery Tray 2.27
19” Adapter 2.27
Wall Mounting 2.28
O U T D O O R S Y S T E M S
2.2
2TecorasOutdoor Cabinet 2.40 bis 2.9
2.3
O U T D O O R S Y S T E M S
O U T D O O R S Y S T E M S
2.4
Individual configuration
- Identical basic and add-onmodules can be easily extendedin modular form to multiplecombinations
- Future security due to installa-tion space and adaption for 19”,metric and non-standard equip-ment, extensive accessory
range- Easy transport of individual mo-
dules and add-on at installationsite
- Damaged covers can be easilyand service-friendly exchanged
Sophisticated engineering
and design
- The use of software tools likePro Mechanica supports tailo-red solutions for all kinds ofenvironmental and mechanicalstress
2
1 Certified safety
- The cabinets meet require-ments in accordance with IEC721, ETS 300 019 and GR-487-CORE
- Minimum 25 dB shielding atte-nuation in accordance with IEC61 587-3
- Earthquake-proof to zone 4 inaccordance with Telcordia GR-63-CORE
- Vibration test in accordancewith IEC 68-2-6, IEC 68-2-29
- Environmentally tested inaccordance withIEC 68-2-1, IEC 68-2-2,IEC 68-2-5, IEC 68-2-56,IEC 60 529
Integrated thermalmanagement
- The integration of the heatexchanger in the enclosure wallensures an increase of the avai-lable usage space by more than15%
- Use of extensive cooling for thefirst time with low cabinet
depths (‹ 400 mm) for use inpublic access areas
- Disruptions of air flow are pre-vented with large spatial sepa-ration of air entry and exitpoints
4
3
TEC000881
Tecoras OutdoorStrong Points
TEC200752
TEC200802 TEC20079 IP-Kammer3
TEC001244
2.5
O U T D O O R S Y S T E M S
Tecoras Outdoor Cabinet
Solar protection roof for basiccabinet with add-on enclosure
Rear cover
Rear panel
Basic rack
Solar protection roof
Cover
Corner extrusions
Side covers
Side panel
Door, closed
Add-on enclosurePlinth cover Plinth
Bottom cover
Plinth trim Door for
air-conditionir
Grey shaded parts with double wall version
only
TEC00332
TEC00319
O U T D O O R S Y S T E M S
2.6
EMC SealingIn standard
IP Protection rating
- IP 55
External covers finish
Powder-coated, RAL 7035 light-grey, outdoor quality in accordan-ce with GSB International, coarsetexture
Load rating
Static up to 4000 N
Options
- Tecoras thermal componentsfor door installation (seethermal management)- Heat exchanger- Cooling unit- Heating (see thermal manage-ment)- Vertical installation extrusions,19” or metric (see accessories)- Cable entry panel (see accesso-
ries)- Cable entry troughs with and
without filter box (see accesso-ries)- Tecoras power supplies andpower distribution (see powersupply systems)
Single or double skinned outdoorenclosure for installation of- 19“ and metric components- Non-standard equipment
Main unit
- Basic frame of extruded alumi-nium AIMgSi0,5 with die-castaluminium corner connectors,polished- Bottom and top cover, rearpanel, corner extrusions andside panels of chrome-platedaluminium AIMg3,1,5 und 2 mm, polished
External covers
- Of 2 mm colourless chrome-plated aluminium AIMg3- 2 Side covers- Rear cover screwed from theinside- Solar protection roof, hinged- All screwing and connectingelements on the inside
Door
Double skinned closed or ventedfor installation of Tecoras ther-mal components- Can be used as front and reardoor, door hinges on right orleft - Strong hidden die-cast alumini-
um hinges- Swing handle for profile half
cylinder with saw protection- Triple interlocking system- The intervening ‘tongue’ in the
rack extrusion ensures highlocking pressure with lowassembly input Door locking with openingangles 90º and 135º
Tecoras OutdoorTechnical data
TEC00443
2.7
O U T D O O R S Y S T E M S
- Double skinned, outdoor enclosure withadd-on capability for installation of- 19” and metric components- Non-standard units with maximuminstallation width, 535 mm- Different cabinet combinations can be
constructed from the same basicmodules.- Double cabinets or triple cabinets are
created by adding-on one or two add-oncabinets ( = basic cabinet without sidecovers and side panels). The extensionis made instead of the side cover.- These combinations can also be moun-
ted on the right or left with an add-onenclosure.
Supply schedule1 Main unit consisting of basic frame, top
and bottom cover, rear panel, 2 corner extrusions1 Rear panel2 Side panels2 Side covers1 Solar protection roof, 110 mm height1 Front door, hinged on right, closed or
vented1 Plinth, 210 mm height, galvanised sheet
steel with 2 side covers, 1 removablefront and rear trim1 Earthing set1 Cable entry panel, closed
Thermal management basic equipping- Naturally ventilated double panels- Naturally ventilated roof
How suppliedFully assembled
TEC00098
W H D HU/U h d kg Model Order no. UP
700 1000 405 895 20 330 63 closed 01.901.003.1 1 unit
700 1180 405 1075 24 330 69 closed 01.901.005.1 1 unit
700 1400 405 1295 29 330 76 closed 01.901.007.1 1 unit
700 1580 405 1475 33 330 81 closed 01.901.009.1 1 unit
700 1000 705 895 20 630 81 closed 01.901.013.1 1 unit
700 1180 705 1075 24 630 88 closed 01.901.015.1 1 unit
700 1400 705 1295 29 630 97 closed 01.901.017.1 1 unit
700 1580 705 1475 33 630 104 closed 01.901.019.1 1 unit
700 1000 405 895 20 330 63 vented 01.901.103.1 1 unit
700 1180 405 1075 24 330 69 vented 01.901.105.1 1 unit
700 1400 405 1295 29 330 76 vented 01.901.107.1 1 unit
700 1580 405 1475 33 330 81 vented 01.901.109.1 1 unit
700 1000 705 895 20 630 81 vented 01.901.113.1 1 unit
700 1180 705 1075 24 630 88 vented 01.901.115.1 1 unit
700 1400 705 1295 29 630 97 vented 01.901.117.1 1 unit
700 1580 705 1475 33 630 104 vented 01.901.119.1 1 unit
Tecoras Basic Cabinet W 700Front door right, closed / vented
See also: the current
Network Special Catalogue!Where you will find more products:
• 19” Rack systems
• Free-standing and wall cabinets
• TFT Drawers
• KVM Switches
• UPS Solutions
• RMS-System
• Thermal management
O U T D O O R S Y S T E M S
2.8
Dimensions in mm: W = Width, H = Height, D = Depth, ESD = ESD version
1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight
Final digit of order number:
.1 = RAL 7035 light-grey
Supply schedule1 Main unit consisting of basic frame, top
and bottom cover, rear panel, 2 cornerextrusions1 Rear panel1 Solar protection roof, 110 mm height1 Front door, hinged on right, closed1 Plinth, 210 mm height, galvanised sheet
steel, 1 removable front and rear trim1 Earthing set1 Cable entry panel, closed1 Add-on set
Thermal management basic equipping- Naturally ventilated rear panel- Naturally ventilated roof
How suppliedFully assembled
Tecoras Add-On Cabinet W 635Front door right, closed / vented
W H D HU/U h d kg Model Order no. UP
635 1000 405 895 20 330 49 closed 01.901.303.1 1 unit
635 1180 405 1075 24 330 52 closed 01.901.305.1 1 unit
635 1400 405 1295 29 330 57 closed 01.901.307.1 1 unit
635 1580 405 1475 33 330 61 closed 01.901.309.1 1 unit
635 1000 705 895 20 630 59 closed 01.901.313.1 1 unit
635 1180 705 1075 24 630 62 closed 01.901.315.1 1 unit
635 1400 705 1295 29 630 67 closed 01.901.317.1 1 unit
635 1580 705 1475 33 630 71 closed 01.901.319.1 1 unit
635 1000 705 895 20 630 59 vented 01.901.413.1 1 unit
635 1180 705 1075 24 630 62 vented 01.901.415.1 1 unit
635 1400 705 1295 29 630 67 vented 01.901.417.1 1 unit
635 1580 705 1475 33 630 71 vented 01.901.419.1 1 unit
TEC00098
- Double skinned compact outdoor enclosurewith double door and central bracket forinstallation of- 2 x 19” and metric components for
cabinet width 1270 mm- Non-standard units with maximuminstallation width, 890 and 1100 mm
- Expansion of the cabinet combinations withadd-on cabinets and add-on enclosures isalso an option
Thermal management basic equipping- Ventilated double panels- Ventilated roof
Double door- Closed or ventilated for using thermal
components - Double door with central bracket- Right and left door can be locked sepa-
rately
Supply schedule1 Main unit consisting of basic frame, top
and bottom cover, 2 side panels, rearpanel, 2 corner extrusions
2 Side covers1 Rear panel cover1 Solar protection roof, 110 mm height1 Double door, hinged on right and left,
closed1 Plinth, 210 mm height, galvanised sheet
steel, with 2 side covers, 1 removablefront and rear trim1 Earthing set2 Cable entry panels, closed
TEC00146
Tecoras Double Door Cabinet W 1270doors closed
W H D HU/U h d kg Model Order no. UP
1270 1000 405 895 20 330 108 01.901.531.1 1 unit
1270 1180 405 1075 24 330 117 01.901.532.1 1 unit
1270 1400 405 1295 29 330 129 01.901.533.1 1 unit
1270 1580 405 1475 33 330 138 01.901.534.1 1 unit
1270 1000 705 895 20 630 136 01.901.536.1 1 unit
1270 1180 705 1075 24 630 147 01.901.537.1 1 unit
1270 1400 705 1295 29 630 161 01.901.538.1 1 unit
1270 1580 705 1475 33 630 172 01.901.539.1 1 unit
2.9
O U T D O O R S Y S T E M S
Dimensions in mm: W = Width, H = Height, D = Depth, ESD = ESD version
1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight
Final digit of order number:
.1 = RAL 7035 light-grey
Double skinned outdoor enclosure withintegrated air-to-air heat exchanger withenclosure protection rating IP 55 forinstallation of:- 19” and metric components- Non-standard units with maximuminstallation width 535 mm (standardcabinet) and 2 x 535 mm(double cabinet)
Integrated heat exchanger principle- Integration of the heat exchanger in theexternal panels- Fans and electronic control board instal-led in the roof for maximum useablespace- Optimised positioning of air entry andexit ensures lowest wind disruption ofthe airflow - Sound pressure level, less than 55 dB(A)
at 1 m distance, in accordance withISO 7779
Thermal management basic equipping- Active ventilated and ribbed side and
rear panels- One fan module with 2 fans with integra-
ted electronic control board 48 VDC forexternal and internal circulation forstandard cabinet with 700 mm width- Two fan modules each with 2 fans withintegrated electronic control board 48VDC for external and internal circulationfor standard cabinet with 1335 mmwidth- Active solar protection with roof fan
Standard cabinet W 700 supply schedule1 Basic frame with bottom cover and 2
corner extrusions 2 Double skinned ribbed side panels withinternal channel plates1 Double skinned ribbed rear panel withinternal channel plate1 Fan module with 2 fans 48 VDC,
thermostat regulated1 Solar protection roof, 195 mm height1 Double skinned front door, hinged on
right, closed1 Plinth, 210 mm height, galvanised sheet
steel, with 2 side covers, 1 removablefront and rear trim1 Earthing set1 Cable entry panel
Double cabinet W 1335 supply scheduleThe double cabinet consists of basic andadd-on cabinets:2 Basic frames with bottom cover and 4
corner extrusions, assembled togetherwith add-on connectors
2 Double skinned ribbed side panels withinternal channel plates
2 Double skinned ribbed rear panels withinternal channel plates
2 Fan modules with 2 fans 48 VDC, ther-mostat regulated
2 Solar protection roofs, 195 mm height2 Double skinned front doors, hinged on
right and left, closed2 Plinths, 210 mm height, galvanised
sheet steel, with 2 side covers,2 removable trims, front and rear
2 Earthing sets2 Cable entry panels, closed
How suppliedFully assembled
Tecoras Heat Exchanger Cabinet
TEC00149
W H D HU/U h d kg Model (*) Order no. UP
700 1000 405 850 19 330 83 28 W/K 01.900.003.1 1 unit
700 1180 405 1030 22 330 89 40 W/K 01.900.005.1 1 unit
700 1400 405 1250 28 330 96 43 W/K 01.900.007.1 1 unit
700 1580 405 1430 32 330 101 48 W/K 01.900.009.1 1 unit
700 1000 705 850 19 630 101 48 W/K 01.900.023.1 1 unit
700 1180 705 1030 22 630 108 55 W/K 01.900.025.1 1 unit
700 1400 705 1250 28 630 117 58 W/K 01.900.027.1 1 unit
700 1580 705 1430 32 630 124 63 W/K 01.900.029.1 1 unit
1335 1000 405 850 19 300 143 55 W/K 01.900.401.1 1 unit
1335 1180 405 1030 22 300 152 68 W/K 01.900.402.1 1 unit
1335 1400 405 1250 28 300 164 70 W/K 01.900.403.1 1 unit
1335 1580 405 1430 32 300 174 78 W/K 01.900.404.1 1 unit
1335 1000 705 850 19 600 171 73 W/K 01.900.411.1 1 unit
1335 1180 705 1030 22 600 182 85 W/K 01.900.412.1 1 unit
1335 1400 705 1250 28 600 196 88 W/K 01.900.413.1 1 unit
1335 1580 705 1430 32 600 207 98 W/K 01.900.414.1 1 unit
* The max. specific cooling capacity refersto the difference between the intake tem-perature of the ambient air and the returntemperature of the interal air
Rapid service
Express Articles
Fast express delivery service,seamless ordering system,
attractive prices and a market–
oriented offer - that’s Knürr
efficiency!
Every express article that is
correspondingly identifed in
this catelogue leaves our
European central stores 24
hours after your order is
received: qualitative high-
grade, standardised solutions,
with which you are always
decisively ahead of the compe-tition.
Our sales offices are also avai-lable for you worldwide, where
competent technicians andsales engineers will personal-ly take care of your specialrequirements.
Why not use these advantagesto your own benefit.
Express articles
in 24 hours ex plant:
With Knürr you are always
ahead of the competition
2TecorasStreet Cabinet 2.120 bis 2.21
2.11
O U T D O O R S Y S T E M S
O U T D O O R S Y S T E M S
2.12
Dimensions in mm: W = Width, H = Height, D = Depth, ESD = ESD version
1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight
Final digit of order number:
.1 = RAL 7035 light-grey
Innovative solution
Street Cabinet side and rear panelsare fabricated from one piece. Thisenables a design with a minimumamount of joints.
Thermal protection
The filter fan installed in the topcover (type Street Cabinet FAN)ensures that hot spots are pre-vented and consequently providesthermal protection for installedequipment.
1
Integrated thermal management
The air-to-air heat exchangerintegrated in the rear panel(Street Cabinet HEC) enablesoptimal cooling in the smallestinstallation area on with protec-tion rating IP 55.
Easy configuration
Together with the enclosure, theearth plinth available as anaccessory made of fibre-glassreinforced polyester provides acompletely configurable ready toconnect system. The compatibil-ity of the connection dimensionswith plinths in accordance withDIN 43629 allows unlimitedexchange of enclosures ofexisting installations.
Functional accessories
The mounting panel with 19”adapter provides flexible upgradewith 19” components and DINrails or non-standard units usedin an application.
Space economy
Space-saving operational ele-ments, displays, telecommunica-tions distributors and power sup-ply components can be mountedin the enclosure with side door.Various front and side doorlocking devices allow separaterights of access.
5
4
3
2
TEC002471
TEC002582
TEC002573
TEC002664
TEC002645
Tecoras Street CabinetStrong points
2.13
O U T D O O R S Y S T E M S
Tecoras Street cabinet
Cladding (L-shaped / U-shaped) Solar protection roof
TEC00312
Cover
Basic rack
Corner extrusion
Door, closed
Bottom cover
Side door
Partition panel
The Tecoras Street cabinets SC, FANand HEC are available in the follo-wing versions:- a basic version with a front door- a basic version with a front door
and an additional side door- a version with a double door on thefront
W H D HU/U w h d kg Model Order no. UP
640 780 375 15 535 675 Street Cabinet SC
740 780 475 15 635 675 Street Cabinet SC
1210 780 15 1105 675 Street Cabinet SC
640 1000 375 20 535 895 Street Cabinet FAN
740 1000 475 20 635 895 Street Cabinet FAN
1210 1000 20 1105 895 Street Cabinet FAN
640 1180 375 24 535 1075 Street Cabinet FAN
740 1180 475 24 635 1075 Street Cabinet FAN
1210 1180 24 1105 1075 Street Cabinet FAN
640 780 400 14 535 630 Street Cabinet HEC
740 780 500 14 635 630 Street Cabinet HEC
1210 780 14 1105 630 Street Cabinet HEC
640 1000 400 19 535 850 Street Cabinet HEC
740 1000 500 19 635 850 Street Cabinet HEC
1210 1000 19 1105 850 Street Cabinet HEC
640 1180 400 23 535 1030 Street Cabinet HEC
740 1180 500 23 635 1030 Street Cabinet HEC
1210 1180 23 1105 1030 Street Cabinet HEC
O U T D O O R S Y S T E M S
2.14
IP Protection rating
- IP 55 For model with closeddoor
- IP 54 For model with ventilateddoor
External covers finish
- Powder-coated, RAL 7035light-grey, outdoor quality inaccordance with GSBInternational, coarse texture
Options
- 1 Plinth, 210 mm height,galvanised sheet steel, withremovable front trim(see accessories)
- 1 Fibre-glass reinforced poly-ester plinth (see accessories)
- Heating (see thermal manage-ment)
- Vertical installation extrusions,19” or metric (see accessories)
- Mounting panel(see accessories)
- Cable entry panel, closed(see accessories)
- Cabinet made of galvanisedsheet steel
Single skinned outdoor enclosure foruse in public access areas with amaximum depth of 500 mm andmaximum height of 1290 mm forinstallation of- 19” and metric components- Non-standard equipment for DIN
rails and fixing mounting panels
Main unit
- Basic frame of extruded alumi-nium AIMgSi0,5 with die-castaluminium corner connectors,polished
- Top and bottom cover of chro-me-plated aluminium AIMg3,2 mm, polished
External covers
- Of 2 mm colourles chrome-plated aluminium AIMg3
- One-piece jacket functioning asside piece and rear panel
- Solar protection roof, screwed- All screwing and connection
elements on the inside
Door
- Standard door or double doorwithout central bracket insingle skinned version, closedor ventilated
- Double skinned door for enclo-sure with increased EMC pro-tection
- Swing handle for profile halfcylinder with saw protection
- Triple interlocking system:The intervening ‘tongue’ in therack extrusion ensures highlocking strength with lowassembly input
- Hidden hinges- Door locking with openingangles 90º and 135º
- The optional side door on theright or left is set up in thesame way as the front door
Tecoras Street CabinetTechnical data
TEC00352
2.15
O U T D O O R S Y S T E M S
Dimensions in mm: W = Width, H = Height, D = Depth, ESD = ESD version
1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight
Final digit of order number:
.1 = RAL 7035 light-grey
TEC00359
Cost-effective single skinned outdoor enclo-sure for installation of- 19” and metric components- Non-standard units with maximum installa-
tion widths, 535 mm and 1105 mm for DINrails and for fixing mounting panel
Supply schedule, SC1 Basic frame with top and bottom cover1 Jacket, U-shaped as side panels and
rear panel1 Solar protection roof1 Front door, sealing on right1 Earthing set
Supply schedule, SC with side door
1 Basic frame with top and bottom cover1 Jacket, U-shaped as side panels and
rear panel1 Solar protection roof, 110 mm height1 Front door, hinged on right1 Earthing set1 Corner extrusion of basic frame1 Side door, left or right1 Partition panel
Supply schedule, SC with double door
1 Basic frame with top and bottom cover1 Jacket, U-shaped as side panels and
rear panel1 Solar protection roof, 110 mm height1 Front door as double door1 Earthing set
How suppliedFully assembled
Tecoras Street Cabinet SCAluminium
W H D HU/U w h d kg Model Order no. UP
640 780 375 15 535 675 335 Street Cabinet 01.917.000.1 1 unit
640 780 475 15 535 675 435 Street Cabinet 01.917.005.1 1 unit
740 780 375 15 635 675 335 Street Cabinet 01.917.010.1 1 unit
740 780 475 15 635 675 435 Street Cabinet 01.917.015.1 1 unit
640 1000 375 20 535 895 335 Street Cabinet 01.917.001.1 1 unit
640 1000 475 20 535 895 435 Street Cabinet 01.917.006.1 1 unit
740 1000 375 20 635 895 335 Street Cabinet 01.917.011.1 1 unit
740 1000 475 20 635 895 435 Street Cabinet 01.917.016.1 1 unit
640 1180 375 24 535 1075 335 Street Cabinet 01.917.002.1 1 unit
640 1180 475 24 535 1075 435 Street Cabinet 01.917.007.1 1 unit
740 1180 375 24 635 1075 335 Street Cabinet 01.917.012.1 1 unit
740 1180 475 24 635 1075 435 Street Cabinet 01.917.017.1 1 unit
740 780 375 15 635 675 335 with side door 01.917.020.1 1 unit
740 780 475 15 635 675 435 with side door 01.917.030.1 1 unit
740 1000 375 20 635 895 335 with side door 01.917.022.1 1 unit
740 1000 475 20 635 895 435 with side door 01.917.032.1 1 unit
740 1180 375 24 635 1075 335 with side door 01.917.024.1 1 unit
740 1180 475 24 635 1075 435 with side door 01.917.034.1 1 unit
1210 780 375 15 1105 675 335 with double door 01.917.040.1 1 unit
1210 780 475 15 1105 675 435 with double door 01.917.045.1 1 unit
1210 1000 375 20 1105 895 335 with double door 01.917.041.1 1 unit
1210 1000 475 20 1105 895 435 with double door 01.917.046.1 1 unit
1210 1180 375 24 1105 1075 335 with double door 01.917.042.1 1 unit
1210 1180 475 24 1105 1075 435 with double door 01.917.047.1 1 unit
O U T D O O R S Y S T E M S
2.16
Dimensions in mm: W = Width, H = Height, D = Depth, d = Useful depth in the entry filter area minus 13 mm, ESD = ESD versi-
on,1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight
Final digit of order number:
.1 = RAL 7035 light-grey
Cost-effective single skinned outdoor
enclosure for installation of- 19” and metric components- Non-standard equipment with maximuminstallation width 535 mm for DIN railsand for fixing mounting panels
Front door
- Ventilated, with entry filter for air intake- Standard or double door without central
bracket- With double door, right and left door
cannot be locked separately
Supply schedule, SC Fan with side door
1 Basic frame with top and bottom cover1 Jacket, U-shaped as side panels and
rear panel1 Solar protection roof, 110 mm height1 Front door, hinged on right1 Axial fan 230 VAC, mounted on the top
cover1 Earthing set1 Corner extrusion of basic frame1 Side door, left or right1 Partition panel
Supply schedule , SC Fan with doubledoor
1 Basic frame with top and bottom cover1 Jacket, U-shaped as side panels and
rear panel1 Solar protection roof, 110 mm height2 Axial fans 230 VAC, mounted on the top
cover1 Front door as double door1 Earthing set
Supply schedule, SC Fan with doubledoor
1 Basic frame with top and bottom cover1 Jacket, U-shaped as side panels and
rear panel1 Solar protection roof, 110 mm height1 Axial fan 230 VAC, mounted on the top
cover1 Front door, sealing on right1 Earthing set
How suppliedFully assembled
Tecoras Street Cabinet Fan
W H D HU/U w h d* Specitif cooling capacity Order no. UP
640 780 375 15 535 675 330 01.917.050.1 1 unit
640 1000 375 20 535 895 330 01.917.051.1 1 unit
640 1180 375 24 535 1075 330 01.917.052.1 1 unit
640 780 475 15 535 675 430 01.917.055.1 1 unit
640 1000 475 20 535 895 430 01.917.056.1 1 unit
640 1180 475 24 535 1075 430 01.917.057.1 1 unit
740 780 375 15 635 657 330 01.917.060.1 1 unit
740 1000 375 20 635 895 330 01.917.061.1 1 unit
740 1180 375 24 635 1075 330 01.917.062.1 1 unit
740 780 475 15 635 675 430 01.917.065.1 1 unit
740 1000 475 20 635 895 430 01.917.066.1 1 unit
740 1180 475 24 635 1075 430 01.917.067.1 1 unit
740 780 375 15 635 657 330 with side door 01.917.070.1 1 unit
740 1000 375 20 635 895 330 with side door 01.917.072.1 1 unit
740 1180 375 24 635 1075 330 with side door 01.917.074.1 1 unit
740 780 475 15 635 657 430 with side door 01.917.080.1 1 unit
740 780 475 20 635 675 430 with side door 01.917.082.1 1 unit
740 1000 475 24 635 895 430 with side door 01.917.084.1 1 unit
1210 780 375 15 1105 675 330 with double door 01.917.090.1 1 unit
1210 1000 375 20 1105 895 330 with double door 01.917.091.1 1 unit
1210 1180 375 24 1105 1075 330 with double door 01.917.092.1 1 unit
1210 780 475 15 1105 675 430 with double door 01.917.095.1 1 unit
1210 1000 475 20 1105 895 430 with double door 01.917.096.1 1 unit
1210 1180 475 24 1105 1075 430 with double door 01.917.097.1 1 unit
* Useable depth is reduced by 13 mm in thearea of the filter
TEC00363
2.17
O U T D O O R S Y S T E M S
TEC00364
Cost-effective single skinned outdoor
enclosure with air-to-air heat exchanger
integrated in the rear panel for installa-tion of- 19” and metric components- Non-standard equipment with maximuminstallation widths, 535 mm and 1105mm for DIN rails and for fixing moun-ting panels
Integrated heat exchanger principle- Integration of the heat exchanger
system in the external panels- Fans and electronic control board instal-led in the roof for maximum useablespace- Optimised postioning of air entry andexit ensures lowest wind disruption ofthe airflow - Sound pressure level, less than 55 dB(A)
at 1 m distance, in accordance withISO 7779
Front door
- Closed- Standard or double door without central
bracket- With double door, right and left door
cannot be locked separately
Supply schedule, SC HEC with side door
1 Basic frame with top and bottom cover1 Side panel1 Double skinned ribbed rear panel withinternal channel plate1 Solar protection roof, 110 mm height1 Front door, hinged on right1 Fan module with 2 fans 48 VDC, moun-
ted on the top cover, thermostat regula-ted
1 Earthing set1 Corner extrusion of basic frame1 Side door, left or right1 Partition panel
Supply schedule, SC HEC1 Basic frame with top and bottom cover2 Side panels1 Double skinned ribbed rear panel withinternal channel plate1 Solar protection roof, 110 mm height1 Front door, hinged on right1 Fan module with 2 fans 48 VDC, moun-
ted on the top cover, thermostat regula-ted1 Earthing set
Supply schedule, SC HEC with doubledoor
1 Basic frame with top and bottom cover2 Side panels1 Double skinned ribbed rear panel withinternal channel plate1 Solar protection roof, 110 mm height1 Front door as double door1 Fan module with 2 fans 48 VDC, moun-
ted on the top cover, thermostat regula-ted1 Earthing set
How suppliedEach fully assembled
* The max. specific cooling capacity refersto the difference between the intaketemperature of the ambiant air and thereturn temperature of the internal air
Tecoras Street Cabinet HEC
W H D HU/U w h d Specific cooling capacity (*) Order no. UP
640 780 375 14 535 630 310 13 W/K 01.917.200.1 1 unit
640 1000 375 19 535 850 310 15 W/K 01.917.201.1 1 unit
640 1180 375 23 535 1030 310 18 W/K 01.917.202.1 1 unit
640 780 475 14 535 630 410 13 W/K 01.917.205.1 1 unit
640 1000 475 19 535 850 410 15 W/K 01.917.206.1 1 unit
640 1180 475 23 535 1030 410 18 W/K 01.917.207.1 1 unit
740 780 375 14 635 630 310 13 W/K 01.917.210.1 1 unit
740 1000 375 19 635 850 310 15 W/K 01.917.211.1 1 unit
740 1180 375 23 635 1030 310 18 W/K 01.917.212.1 1 unit
740 780 475 14 635 630 410 13 W/K 01.917.215.1 1 unit
740 1000 475 19 635 850 410 15 W/K 01.917.216.1 1 unit
740 1180 475 23 635 1030 410 18 W/K 01.917.217.1 1 unit
740 780 375 14 635 630 310 13 W/K with side door 01.917.220.1 1 unit
740 1000 375 19 635 850 310 15 W/K with side door 01.917.222.1 1 unit
740 1180 375 23 635 1030 310 18 W/K with side door 01.917.224.1 1 unit
740 780 475 14 635 630 410 13 W/K with side door 01.917.230.1 1 unit
740 1000 475 19 635 850 410 15 W/K with side door 01.917.232.1 1 unit
740 1180 475 23 635 1030 410 18 W/K with side door 01.917.234.1 1 unit
1210 780 375 14 1105 630 310 25 W/K with double door 01.917.240.1 1 unit
1210 1000 375 19 1105 850 310 30 W/K with double door 01.917.241.1 1 unit
1210 1180 375 23 1105 1030 310 33 W/Kwith double door 01.917.242.1 1 unit
1210 780 475 14 1105 630 410 25 W/K with double door 01.917.245.1 1 unit
1210 1000 475 19 1105 850 410 30 W/K with double door 01.917.246.1 1 unit
1210 1180 475 23 1105 1030 410 33 W/K with double door 01.917.247.1 1 unit
* The max. specific cooling capacity refersto the difference between the intaketemperature of the ambient air and thereturn temperature of the interal air
TEC20050
O U T D O O R S Y S T E M S
2.18
Dimensions in mm: W = Width, H = Height, D = Depth, ESD = ESD version
1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight
Final digit of order number:
.1 = RAL 7035 light-grey
TEC00327
TEC00333
- With mounting holes for caged nuts- For 19” (EN60 297) or metric installations(EN 60 917)
MaterialExtruded aluminium, polished
Supply schedule2 Vertical extrusions with mountingmaterial
Vertical Extrusion with Mounting Holes
W H D HU/U w h d kg Model Order no. UP
15 19” installation 01.908.001.0 1 unit
20 19” installation 01.908.002.0 1 unit
24 19” installation 01.908.003.0 1 unit
29 19” installation 01.908.005.0 1 unit
33 19” installation 01.908.006.0 1 unit
27 M metric installation 01.908.201.0 1 unit
36 M metric installation 01.908.202.0 1 unit
43 M metric installation 01.908.203.0 1 unit
52 M metric installation 01.908.205.0 1 unit
59 M metric installation 01.908.206.0 1 unit
TEC00330
- For safe securing and fixing of batteries inTecoras Outdoor Cabinets and StreetCabinets- Load rating 130 kg
MaterialZinc passivated sheet steel, 2 mm
FinishPowder-coatedRAL 7035 light-grey, coarse texture
Supply schedule1 Battery tray1 Anti-slip mat of Neopren4 Fixing straps, 4 tightening straps withpolyamid Velcro fastener
Mounting material
Battery Tray
W H D HU/U w h d kg Model Order no. UP
640 400 220 bottom mounted 01.908.300.1 1 unit
640 700 400 bottom mounted 01.908.301.1 1 unit
640 700 400 extrusion mounted 01.908.302.1 1 unit
- For the secure mounting of shortenedvertical extrusions and for cable manage-ment in Tecoras Outdoor Cabinets andStreet Cabinets
MaterialStainless steel, 1.5 mm, polished
Supply schedule1 Deep strut with mounting material
Depth Strut
W H D HU/U w h d kg Model Order no. UP
400 01.908.100.0 1 unit
700 01.908.101.0 1 unit
2.19
O U T D O O R S Y S T E M S
FeaturesWith mounting bracketEnergy-effective lampOn / Off switchWith coverSafety socket optionally
ApprovalVDE
Protection rating IP20
Operating temperature- 30 to +60º C
Technical data- Operating voltage48 VDC or 230 V/50 Hz- Light material
Compact fluorescent lamp withintegrated starter- Power consumption11 W =̂ 75 W filament lamp- Light intensity900 Lm- Interference suppressionin accordance with VDE 0712, IEC 82- Connections
2-or 3-pole screw terminal, 2.5 mm2
with strain relief
Compact Cabinet Lamp
W H D HU/U w h d kg Model Order no. UP
400 70 65 DC 01.908.711.9 1 unit
400 70 65 AC 01.908.712.9 1 unit
ELM00135
- Switching voltage 200 V DC, 0.5 AContact rating 10 W- Activation with door opening and closing- The magnet is fitted into the cam of thelatching system
Supply schedule1 Door contact switch with 1.5 m long
cable1 Mounting bracketMounting material1 Magnet
Door Contact SwitchMagnetically
W H D HU/U w h d kg Model Order no. UP
01.908.701.0 1 unitELM00137
See also: the current
Network Special Catalogue!Where you will find more products:
• 19” Rack systems
• Free-standing and wall cabinets
• TFT Drawers
• KVM Switches
• UPS Solutions
• RMS-System
• Thermal management
O U T D O O R S Y S T E M S
2.20
Dimensions in mm: W = Width, H = Height, D = Depth, ESD = ESD version
1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight
Final digit of order number:
.1 = RAL 7035 light-grey
- For space-saving and safe cable penetrationin Tecoras Outdoor Cabinets und StreetCabinets- Mounting in the bottom cover of the
cabinets- Mounting of the cable entry trough andfilter box underneath the vertical extru-sions, resulting in optimal space utiliza-tion
- Cable entry panels, cable entry troughs canbe interchanged with one another- Filter box is suitable for installation of ACdistributors, overvoltage protectors,bushing-type filters and mains filters
Material- Aluminium 2 mm, colourless
chrome-plated, polished
Supply schedule1 Closed cable entry panelor1 Cable entry trough (option: 1 cable entry
trough with filter box, EMC shielded, notequipped)
Each with mounting material
Cable Entry Panels and Troughs / Filter Box Shielded
W H D HU/U w h d Model Order no. UP
390 145 cable entry panel closed 01.908.605.8 1 unit
490 145 cable entry panel closed 01.908.601.8 1 unit
490 145 cable entry trough 01.908.660.8 1 unit
490 145 cable entry trough with filter 01.908.661.8 1 unit
TEC00444
- For vandalism-proof and stable installationof Tecoras outdoor Street Cabinets
MaterialStainless steel, 2 mm
FinishPowder-coatedRAL 7035 light-grey, outdoor quality inaccordance with GSB International,coarse textured
Design- Welded frame with removable front trim- The front trim can only be removed
when the door of the cabinet is open- The bolting of the plinth to the cabinet isnot externally accessible
Supply schedule1 Plinth1 Front trimMounting material for mounting thecabinet on to the plinth
Metal Plinth
W H D HU/U w h d Model Order no. UP
640 210 375 0 01.914.305.1 1 unit
740 210 375 1 01.914.303.1 1 unit
1210 210 375 2 01.914.307.1 1 unit
640 210 475 0 01.914.306.1 1 unit
740 210 475 1 01.914.304.1 1 unit
1210 210 475 2 01.914.308.1 1 unit
TEC00245
TEC00273
2.21
O U T D O O R S Y S T E M S
Dimensions in mm: W = Width, H = Height, D = Depth, ESD = ESD version
1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight
Final digit of order number:
.1 = RAL 7035 light-grey
Design- Self-bearing design- The front trim can only be removed
when the cabinet door has first beenopened- The bolting of the plinth to the cabinet isnot externally accessible
Supply schedule1 Plinth, flat-packed in2 Side panels1 Rear panel1 Partitioned front panel, stabilization
rails1 Adaption set
How suppliedFlat-packed kit
MaterialFibre-glass reinforced polyester for weather-resistant soil installations ofTecoras Street Cabinets- Easily mounted- Comfortable transport weight (max. 20 kg)- Compatible with DIN 43629 part 2,
standard plinth for cable distributor andinstrument cabinet
Colour
Grey, similar to RAL 9002
Fibre-Glass Reinforced Polyester Plinth
W H D HU/U w h d Model Order no. UP
591 900 375 495 0 01.914.394.1 1 unit
786 900 375 690 1 01.914.395.1 1 unit
1116 900 375 1020 2 01.914.396.1 1 unit
591 900 475 495 0 01.914.397.1 1 unit
786 900 475 690 1 01.914.398.1 1 unit
1116 900 475 1020 2 01.914.399.1 1 unit
TEC00243
TEC00272
MaterialGalvanised sheet steeel, 2 mm, polished
Supply schedule1 Mounting panel with mounting material
Option:19” adapter 3 HU for fixing to themounting panel
- For mounting installations for DIN rail fixingand non-standard equipment in TecorasOutdoor Cabinets and Street Cabinets withadaption options for 19” modular chassis’
Mounting Panel
W H D HU/U w h d Model Order no. UP
535 15 01.908.751.7 1 unit
535 20 01.908.752.7 1 unit
535 24 01.908.753.7 1 unit
535 29 01.908.754.7 1 unit
535 33 01.908.755.7 1 unit
TEC00249
Rapid service
Express Articles
Fast express delivery service,seamless ordering system,
attractive prices and a market–
oriented offer - that’s Knürr
efficiency!
Every express article that is
correspondingly identifed in
this catelogue leaves our
European central stores 24
hours after your order is
received: qualitative high-
grade, standardised solutions,
with which you are always
decisively ahead of the compe-tition.
Our sales offices are also avai-lable for you worldwide, where
competent technicians andsales engineers will personal-ly take care of your specialrequirements.
Why not use these advantagesto your own benefit.
Express articles
in 24 hours ex plant:
With Knürr you are always
ahead of the competition
2TecorasOutdoor Wall Case 2.240 bis 2.28
2.23
O U T D O O R S Y S T E M S
O U T D O O R S Y S T E M S
2.24
Single skinned climatised and uncli-matised outdoor enclosures formounting on walls and poles andbase assembly, for installation of- 19” and metric components- Non-standard equipment for DIN
rails and fixing mounting panels
Integrated thermal management
The air-to-air heat exchanger inte-grated in the side panels (with wallcase HEC) enables optimalcooling with the smallest installationspace with protection rating IP 55.
Outdoor Wall CaseStrong points
TEC00329
IP Protection rating- IP 55 for model with closeddoor (Wall Case, Wall CaseHEC)
EMC ProtectionOptional
External covers finishPowder-coatedRAL 7035 light-grey Outdoor quality in accordancewith GSB International, coarsetexture
Load ratingStatic up to 500 N
Main unitWelded enclosure body of 3 mmchrome-plated aluminium AIMg3
External covers (only for wallenclosures with integrated heatexchanger)
- Of colourless chrome-platedaluminium AIMg3, 2 mm- Solar protection roof, screwed/
bolted- All bolting and connectionelements on the inside
Door
- Door closed or ventilated- Of colourless chrome-plated
aluminium AIMg3, 2 mm- Double skinned door model forenclosures with high EMC pro-tection rating- Door hinged right or left- Swing handle for profile half
cylinder- Double interlocking system- Hidden hinges- Door hinge to maximumopening angle of 150º
Outdoor Wall CaseTechnical data
2.25
O U T D O O R S Y S T E M S
Dimensions in mm: W = Width, H = Height, D = Depth, ESD = ESD version
1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight
Final digit of order number:
.1 = RAL 7035 light-grey
Cost-effective outdoor wall enclosure for
installation of- Non-standard equipment with installati-on widths of 305 to 485 mm for DIN railsand fixing mounting panels- 19” Components (only for enclosure
width 585 mm)
Supply schedule1 Wall case with mounting straps formounting on the wall1 Front door, closed,hinged on left side1 Closed cable entry panel in the bottom1 Mounting panel of 2 mm zinc passivated
sheet steel, polished, mounted on therear side1 Earthing set
How suppliedFully assembled
OptionWith axial fan 230 V AC, controlled bythermostat
Outdoor Wall Case
W H D HU/U w h d Model Order no. UP
405 400 250 7 305 340 210 01.915.002.1 1 unit
485 400 250 7 385 340 210 01.915.004.1 1 unit
405 600 250 12 305 540 210 01.915.006.1 1 unit
485 600 250 12 385 540 210 01.915.008.1 1 unit
485 600 345 12 385 540 305 01.915.010.1 1 unit
585 600 345 12 485 540 305 01.915.012.1 1 unit
485 800 250 16 385 740 210 01.915.014.1 1 unit
485 800 345 16 385 740 305 01.915.016.1 1 unit
585 800 345 16 485 740 305 01.915.018.1 1 unit
TEC00121
TEC00329
O U T D O O R S Y S T E M S
2.26
Double skinned outdoor wall case with air-to-air heat exchanger integrated in the sidepanels for installation of- 19” Components (for cabinet width 650 mm)- Non-standard equipment with installation
widths of 305 to 485 mm for DIN rails andfixing of mounting panels
Integrated heat exchanger principle- Integration of the heat transfer systemin the side panels- Fans and electronic control board instal-led in the roof for maximum useablespace- Optimised postioning of air entry andexit ensures lowest wind disruption ofthe airflow - Sound pressure level, less than 55 dB(A)
at 1 m distance, in accordance withISO 7779
Supply schedule1 Wall case2 Double skinned ribbed side panels withinternal channel plate1 Solar protection roof1 Front door, closed,hinged on right1 Fan module with 2 fans 48 VDC,mounted on the cover,thermostat regulated1 Closed cable entry panel in the bottom1 Earthing set
How suppliedFully assembled
Outdoor Wall Case HEC
TEC00150
Dimensions in mm: W = Width, H = Height, D = Depth, ESD = ESD version
1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight
Final digit of order number:
.1 = RAL 7035 light-grey
TEC00125
W H D HU/U w h d Specific cooling capacity* Order no. UP
550 700 345 11 385 540 290 18 W/K 01.914.500.1 1 unit
650 700 345 11 485 540 290 18 W/K 01.914.502.1 1 unit
650 700 445 11 485 540 390 20 W/K 01.914.510.1 1 unit
550 900 345 15 385 740 290 20 W/K 01.914.504.1 1 unit
650 900 345 15 485 740 290 23 W/K 01.914.506.1 1 unit
650 900 445 15 485 740 390 23 W/K 01.914.508.1 1 unit
* The max. specific cooling capacity refersto the difference between the intaketemperature of the ambient air and thereturn temperature of the internal air
2.27
O U T D O O R S Y S T E M S
Dimensions in mm: W = Width, H = Height, D = Depth, ESD = ESD version
1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight
Final digit of order number:
.1 = RAL 7035 light-grey
- For safe securing and fixing of batteries inTecoras Outdoor Wall Cases- For mounting on the 19” installation- Load rating 60 kg
MaterialZinc passivated sheet steel, 2 mm,polished
Supply schedule1 Battery tray2 Chassis runners1 Anti-slip mat made of NeoprenMounting material
Battery Tray
W H D HU/U w h d kg Model Order no. UP
650 455 450 25 285 01.908.309.7 1 unit
TEC00361
- With mounting holes for caged nuts
MaterialAluminium, 2 mm, polished
Supply schedule2 Side panels with integrated 19”mounting holes
Mounting bracketMounting material
19” Adapter
W H D HU/U w h d kg Model Order no. UP
700 450 11 330 01.914.840.7 1 unit
900 750 15 330 01.914.841.7 1 unitTEC00362
See also: the current
Network Special Catalogue!Where you will find more products:
• 19” Rack systems
• Free-standing and wall cabinets
• TFT Drawers
• KVM Switches
• UPS Solutions
• RMS-System
• Thermal management
O U T D O O R S Y S T E M S
2.28
- Wall mounting with/without pole support
Material- Frame, sheet steel and case extrusion of
steel- Console, stainless steel, 1.5 mm
Option- Pole mounting for fixing to the frame of
the wall mounting for pole diameters 50,100, 150 and 200 mm
- Material, stainless steel- Supply schedule: 2 clamps, 1 rear panel
for the frame, mounting material
Supply schedule1 Frame1 Console, consisting of 2 side panels1 Front trim with fastener1 Base cover
How suppliedFlat-packed kit
Wall Mounting for Wall Case HEC
W H D HU/U w h d kg Model Order no. UP
550 700 350 01.914.488.1 1 unit
650 700 350 01.914.489.1 1 unit
650 700 450 01.914.490.1 1 unit
550 900 350 01.914.491.1 1 unit
650 900 350 01.914.492.1 1 unit
650 900 450 01.914.493.1 1 unit
TEC00155
TEC00360
Dimensions in mm: W = Width, H = Height, D = Depth, ESD = ESD version
1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight
Final digit of order number:
.1 = RAL 7035 light-grey
3ThermalManagementIndoor 3.2 to 3.12
Outdoor 3.13 to 3.18
3.1
T H E R M A L M A N A G E M E N T
ThermalManagementIndoor
dart fan unitStrong Points 3.5
dart fan units 3.6
Accessories 3.10
Heat exchanger 3.10
Cooling Unit 3.12
ThermalManagementOutdoor
Tecoras
Strong Points 3.16
Air-to-air Heat exchanger 3.18
Cooling unit 3.19
Heating unit 3.20
T H E R M A L M A N A G E M E N T
3.2
3TecorasIndoor 3.4 to 3.14
3.3
T H E R M A L M A N A G E M E N T
LUF002691
LUF002681
LUF002782
0–1 1–2 2–3 3–4 4–5
Air speed in m/s
0–1 1–2 2–3 3–4 4–5
Air speed in m/s
T H E R M A L M A N A G E M E N T
3.4
3.5
T H E R M A L M A N A G E M E N T
Easy filter change while
operating: Fresh air from outsideincreases the cooling perform-ance. A built-in filter mat therebyprotects your components fromcontamination.The filter mat is changed at thefront – this can be done while theunit is operating.The front panel is removed withquick-release fasteners.Downtimes are consequentlyavoided.
The airmatic 19” tangential fanis the ideal ventilation insert formodular chassis’ with printed cir-cuit boards in Eurocard format.A uniform cooling of the electro-nics is guaranteed with an evenlydistributed airflow over the entirewidth of the unit. The airflowmonitoring signals dirt build-upon the filter mat and fan failure ingood time, and consequently pro-tects the installations fromoverheating.
With increased requirements withregard to IP protection (water/dust)and very high power loss of the elec-tronics, heat exchangers and cool-ling equipment are utilised.
6
5Heat transfer by ventilation (forcedconvection) is a very effectivemethod.19” Fan units provide forced air flowthrough the enclosure.Hot spots are targetted and elimina-ted with single fans and fan frontpanels.Fan installation sets and stackablefans can also be integrated later on.
The specialised ventilation sys-tem of the dart fan unit providesuniform through flow for all elec-tronics that require cooling.Marginal areas are also cooled inthe process. Conventional posi-tioning of axial fans is known tocause numerous unventilatedareas.
No heat build-up under the fan:With modular chassis’ that liebelow the fan, the specialiseddesign of the 2 HU fan unit ena-bles air dissipation to the rear.
Automatic regulation of the ven-tilation with temperature sensor.By adapting to the actual require-ments, the fans attain longer life-spans and lower noise levels.
The 19” filter insert provides fil-tered air and thereby preventscontamination of your internalcomponents.
4
3
2
1
dart fan unitStrong points
LUF002054
LUF00279_13
LUF002715
LUF002066
LUF00272
T H E R M A L M A N A G E M E N T
3.6
For vertical ventilation of 19” racks andenclosures
To prevent hot spots
Even air distribution across the entirewidth and depth of the fan unit
VariantsType 1- for input voltage 230 VAC / 50 HzType 2- for input voltage 115 VAC / 60 HzType 3- for input voltage 24 VDCType 4- for input voltage 48 VDC
Tests- Vibration test in accordance with
MIL-STD 810 E
Approvals- CE label in accordance with the lowpotential guidline 73/23/EWG, EMCguideline 89/336/EWG
Material- Sheet steel
Finish / Colour- Enclosure: zinc-plated- Front panel: powder-coated smooth
RAL 7035 light grey
Technical data single fanType 1- Voltage: 230 VAC (207-243 VAC)- Frequency: 50 Hz- Max. volume flow: 117 m3/h- Power consumption: 14 W- Noise freely blowing: 37 dB(A)- Bearing system: solid bearing- Nominal fan speed: 2450 min-1- Permitted environmental temperature-20...+70°C- Estimated life expectancy L10 at 40°C:47500 h
Type 2- Voltage: 115 VAC (104-121 VAC)- Frequency: 60 Hz- Max. volume flow: 135 m3/h- Power consumption: 12 W- Noise freely blowing: 42 dB(A)- Bearing system: solid bearing- Nominal fan speed: 2850 min-1- Permitted environmental temperature-20...+70°C- Estimated life expectancy L10 at 40°C:52500 h
Type 3- Voltage: 24 VDC (12-28 VDC)- Max. volume flow: 170 m3/h- Power consumption: 5 W- Noise freely blowing: 43 dB(A)- Bearing system: solid bearing- Nominal fan speed: 2900 min-1- Permitted environmental temperature-20...+70°C- Estimated life expectancy L10 at 40°C:
62500 h
Type 4- Voltage: 48 VDC (43-53 VDC)- Max. volume flow: 117 m3/h- Power consumption: 6.5 W- Noise freely blowing: 43 dB(A)- Bearing system: solid bearing- Nominal fan speed: 2900 min-1- Permitted environmental temperature-20...+65°C- Estimated life expectancy L10 at 40°C:52500 h
Supply scheduleType 11 Fan unit1 Power supply lead 2 m with safety plugType 21 Fan unit1 Power supply lead 2 m according to US
standardType 31 Fan unit1 Power supply lead 2 m without plugType 41 Fan unit1 Power supply lead 2 m without plug
Please note- For assembly chassis runner arenecessary
dart 19” vertical fan unit 1 U uncontrolled
WW HH DD nnuummbbeerr ooff ffaannss MMooddeell OOrrddeerr nnoo.. UUPP
193,5 3 230 VAC (207-243 VAC) 03.026.103.1 1 unit
385,5 6 230 VAC (207-243 VAC) 03.026.106.1 1 unit
193,5 3 115 VAC (104-121 VAC) 03.026.104.1 1 unit
385,5 6 115 VAC (104-121 VAC) 03.026.107.1 1 unit
193,5 3 24 VDC (12-28 VDC) 03.026.105.1 1 unit
385,5 6 24 VDC (12-28 VDC) 03.026.108.1 1 unit
193,5 3 48 VDC (43-53 VDC) 03.026.120.1 1 unit
385,5 6 48 VDC (43-53 VDC) 03.026.121.1 1 unit
LUF00274
3.7
T H E R M A L M A N A G E M E N T
Increased cooling capacity through frontalair intake
Filter mat can be changed from frontduring operation without need of tools
Even air distribution across the entirewidth and depth of the fan unit
VariantsType 1- for input voltage 230 VAC / 50 HzType 2- for input voltage 115 VAC / 60 HzType 3- for input voltage 24 VDCType 4- for input voltage 48 VDC
Tests- Vibration test in accordance with
MIL-STD 810 E
Approvals- CE label in accordance with the lowpotential guidline 73/23/EWG,EMC guideline 89/336/EWG
Material- Enclosure, front panel: sheet steel
Finish / Colour- Enclosure: zinc-plated- Front panel: powder-coated smooth
RAL 7035 light grey
Technical data single fanType 1- Voltage: 230 VAC (207-243 VAC)- Frequency: 50 Hz- Max. volume flow: 117 m3/h- Power consumption: 14 W- Noise openly blowing: 37 dB(A)- Bearing system: solid bearing- Nominal fan speed: 2450 min-1- Permitted environmental temperature-20...+70°C- Estimated life expectancy L10 at 40°C:47500 h
Type 2- Voltage: 115 VAC (104-121 VAC)- Frequency: 60 Hz- Max. volume flow: 135 m3/h- Power consumption: 12 W- Noise openly blowing: 42 dB(A)- Bearing system: solid bearing- Nominal fan speed: 2850 min-1- Permitted environmental temperature-20...+70°C- Estimated life expectancy L10 at 40°C:52500 h
Type 3- Voltage: 24 VDC (12-28 VDC)- Max. volume flow: 170 m3/h- Power consumption: 5 W- Noise freely blowing: 43 dB(A)- Bearing system: solid bearing- Nominal fan speed: 2900 min-1- Permitted environmental temperature-20...+70°C- Estimated life expectancy L10 at 40°C:
62500 h
Type 4- Voltage: 48 VDC (43-53 VDC)- Max. volume flow: 117 m3/h- Power consumption: 6.5 W- Noise freely blowing: 43 dB(A)- Bearing system: solid bearing- Nominal fan speed: 2900 min-1- Permitted environmental temperature-20...+65°C- Estimated life expectancy L10 at 40°C:52500 h
Supply scheduleType 11 Fan unit1 Power supply lead 2 m with safety plug1 Filter mat viledon P15/150Type 21 Fan unit1 Power supply lead 2 m according to
US standard1 Filter mat viledon P15/150Type 31 Fan unit1 Power supply lead 2 m without plug1 Filter mat viledon P15/150Type 41 Fan unit1 Power supply lead 2 m without plug1 Filter mat viledon P15/150
How supplied- Assembled, wired and tested
dart 19” fan unit with frontal air intake 2 U uncontrolled
LUF00273
LUF00275
W H D number of fans Model Order no. UP
193,5 3 230 VAC (207-243 VAC) 03.026.203.1 1 unit
193,5 3 115 VAC (104-121 VAC) 03.026.204.1 1 unit
193,5 3 24 VDC (12-28 VDC) 03.026.205.1 1 unit
193,5 3 48 VDC (43-53 VDC) 03.026.122.1 1 unit
T H E R M A L M A N A G E M E N T
3.8
Temperature measurement via PTC probewith 2 m line, plug-in a the rear
Nominal temperature at potentiometercan be set
Fan control of 30-100% of the nominalspeed, with failure of the temperatureprobe maximum speed
Individual fan monitoring
For vertical ventilation of 19” racks andenclosures
To prevent hot spots
Even air distribution across the entirewidth and depth of the fan unit
VariantsType 1- for input voltage 115/230 VAC(93-253 VAC), 50/60 Hz
Type 2- for input voltage 24 VDC(12 VDC-28 VDC)
Type 3- for input voltage 48 VDC (36-72 VDC)
Output signals
Optical display frontal (3 LED’s)- green system ok- red fan failure- red nominal temperature
exceeding
Acoustic error message(can be turned off via reset key) with:exceeding the nominal temperature- Fan failure
Floating contact (type changeovercontact, load rating 230 V / 1A, incl. signalline 2 m) on the rear to report errors with:exceeding the nominal temperature- Fan failure- Power failure
Tests- Vibration test in accordance with
MIL-STD 810 E
Approvals- CE label in accordance with the lowpotential guidline 73/23/EWG,EMC guideline 89/336/EWG
Material- Sheet steel
Finish / Colour- Enclosure: zinc-plated- Front panel: powder-coated smooth
RAL 7035 light grey
Technical data single fanType 1- Voltage: 24 VDC (12-28 VDC)- Max. volume flow: 170 m3/h- Power consumption: 5 W- Noise openly blowing: 43 dB(A)- Bearing system: solid bearing- Nominal fan speed: 2900 min-1- Permitted environmental temperature-20...+70°C- Estimated life expectancy L10 at 40°C:
62500 h
Supply scheduleType 11 Fan unit1 Power supply lead 2 m with euro plug1 Temperature probe with cable 2 m1 Signal line 2 m (plug-in)Type 21 Fan unit1 Filter mat viledon P15/1501 Power supply lead 2 m without plug1 Temperature probe with cable 2 m1 Signal line 2 m (plug-in)Type 31 Fan unit1 Filter mat viledon P15/1501 Power supply lead 2 m without plug1 Temperature probe with cable 2 m1 Signal line 2 m (plug-in)
How supplied- Assembled, wired and tested
Please note- For assembly chassis runner arenecessary
dart 19” vertical fan unit 1 U speed-controlled
LUF00272
DAR20005
W H D number of fans Model Order no. UP
193,5 3 115/230 VAC (93-256 VAC) 03.026.113.1 1 unit
385,5 6 115/230 VAC (93-256 VAC) 03.026.116.1 1 unit
193,5 3 24 VDC (12-28 VDC) 03.026.115.1 1 unit
385,5 6 24 VDC (12-28 VDC) 03.026.118.1 1 unit
193,5 3 48 VDC (36-72 VDC) 03.026.130.1 1 unit
385,5 6 48 VDC (36-72 VDC) 03.026.131.1 1 unit
3.9
T H E R M A L M A N A G E M E N T
Temperature measurement via PTC probewith 2 m line, plug-in a the rear
Nominal temperature at potentiometercan be set
Fan control of 30-100% of the nominalspeed, with failure of the temperatureprobe maximum speed
Individual fan monitoring
For vertical ventilation of 19” racks andenclosures
To prevent hot spots
Even air distribution across the entirewidth and depth of the fan unit
VariantsType 1- for input voltage 115/230 VAC(93-253 VAC), 50/60 Hz
Type 2- for input voltage 24 VDC(12 VDC-28 VDC)
Type 3- for input voltage 48 VDC(36-72 VDC)
Output signals
Optical display frontal (3 LED’s)- green system ok- red fan failure- red nominal temperature
exceeding
Acoustic error message(can be turned off via reset key) with:exceeding the nominal temperature- Fan failure
Floating contact (type changeovercontact, load rating 230 V / 1A, incl. signalline 2 m) on the rear to report errors with:exceeding the nominal temperature- Fan failure- Power failure
Tests- Vibration test in accordance with
MIL-STD 810 E
Approvals- CE label in accordance with the lowpotential guidline 73/23/EWG,EMC guideline 89/336/EWG
Material- Sheet steel
Finish / Colour- Enclosure: zinc-plated- Front panel: powder-coated smooth
RAL 7035 light grey
Technical data single fan- Voltage: 24 VDC (12-28 VDC)- Max. volume flow: 170 m3/h- Power consumption: 5 W- Noise openly blowing: 43 dB(A)- Bearing system: solid bearing- Nominal fan speed: 2900 min-1- Permitted environmental temperature-20...+70°C- Estimated life expectancy L10 at 40°C:
62500 h
Supply scheduleType 11 Fan unit1 Filter mat viledon P15/1501 Power supply lead 2 m with euro plug1 Temperature probe with cable 2 m1 Signal line 2 m (plug-in)Type 21 Fan unit1 Filter mat viledon P15/1501 Power supply lead 2 m without plug1 Temperature probe with cable 2 m1 Signal line 2 m (plug-in)Type 31 Fan unit1 Filter mat viledon P15/1501 Power supply lead 2 m without plug1 Temperature probe with cable 2 m1 Signal line 2 m (plug-in)
How supplied- Assembled, wired and tested
dart 19” fan unit with frontal air intake 2 U speed-controlled
LUF00273
DAR20004
W H D number of fans Model Order no. UP
193,5 3 115/230 VAC (93-256 VAC) 03.026.213.1 1 unit
193,5 3 24 VDC (12-28 VDC) 03.026.215.1 1 unit
193,5 3 48 VDC (36-72 VDC) 03.026.214.1 1 unit
T H E R M A L M A N A G E M E N T
3.10
For Dart 19” fan unit front intake, 2 U Material- Viledon P15/150
Supply schedule1 Set at 5 items
How supplied- In batches
dart replacement filter
W H D HU/U w h d kg Model Order no. UP
01.171.217.9 1 unitSMA20058
Temperature control via thermostaticregulated magnet valve
High cooling output with low energyconsumption and extremely compact 2 HUdesign
No danger to electronics with dustdeposits and splash water
Uniform temperature distribution in thecabinet
Service-free operation without fan
Degree of protection- IP 44
Approvals- CE
Technical data
Electrical supply values(supply in the terminal strip)- Mains voltage: 230 V- Nominal frequency: 50 Hz- Nominal current: 0.4 A- Power consumption: 80 W
Power data- Effective cooling power L35W10: 1000 W
with 200l/h water throughput- Maximum cabinet air flow 180 m3/h,
speed controlled- Operating pressure: max. 10 bar- Temperature range: +1°C to +72°- Refrigerant: water, light oils or similar- Weight: 13 kg- Noise level: 52 dB(A) at 1 m distance
with maximum air output
Output signals- High temperature alarm
Material- Enclosure: stainless steel- Front panel: aluminium 3mm
Finish / Colour- Enclosures and front panel, powder-
coated, textured, RAL 7035 light grey- Handles, powder-coated, textured,
RAL 5008 grey blue
Supply schedule1 Heat exchanger1 Mains supply cable1 Supply cable for tube1 Supply coupling for tube1 Condensation tubeOperating instructions
How supplied- In flat packed kits
19” Heat exchanger, 1000 W
W H D HU/U w h d kg Model Order no. UP
443 87 405 03.032.320.1 1 unit
LUF20007
LUF20011
3.11
T H E R M A L M A N A G E M E N T
Temperature control via water quantilyregulator
High cooling output with low energyconsumption and extremely compact 4 HUdesign
No danger to electronics with dustdeposits and splash water
Uniform temperature distribution in thecabinet
Service-free operation without fan
Degree of protection- IP 44
Approvals- CE
Technical data
Electrical supply values(supply in the terminal strip)- Mains voltage: 230 V- Nominal frequency: 50 Hz- Nominal current: 0.45 A- Power consumption: 100 W
Power data- Effective cooling power L35W10: 2000 W
with 200l/h water throughput- Maximum cabinet air flow 180 m3/h,
speed controlled- Operating pressure: max. 10 bar- Temperature range: +1°C to +72°- Refrigerant: water, light oils or similar- Weight: 16.5 kg- Noise level: 52 dB(A) at 1 m distance
with maximum air output
Output signals- High temperature alarm
Material- Enclosure: stainless steel- Front panel: aluminium 3mm
Finish / Colour- Enclosures and front panel, powder-
coated, textured, RAL 7035 light grey- Handles, powder-coated, textured,
RAL 5008 grey blue
Supply schedule1 Heat exchanger1 Mains supply cable1 Supply cable for tube1 Supply coupling for tube1 Condensation tubeOperating instructions
How supplied- In batches
19” Heat exchanger, 2000 W
W H D HU/U w h d kg Model Order no. UP
443 175 505 03.032.322.1 1 unit
LUF20006
LUF20010
See also: the current
Network Special Catalogue!Where you will find more products:
• 19” Rack systems
• Free-standing and wall cabinets
• TFT Drawers
• KVM Switches
• UPS Solutions
• RMS-System
• Thermal management
T H E R M A L M A N A G E M E N T
3.12
Service-free operation with patentedconstruction without filter
High cooling output with compact design
CFC-free refrigerant, R 134a
Uniform temperature distribution in thecabinet
Approvals- CE
Degree of protection- IP 44
Technical data
Electrical supply values- Nominal voltage: 230 V- Nominal frequency: 50 Hz- Nominal current: 4.5 A- Max. starting current: 9 A- Power consumption: 850 W
Power data- Effective cooling power L35W35: 1000 W- Maximum cabinet air flow 360 m3/h,
speed-controlled- Maximum cabinet air flow 720 m3/h,
speed controlled- Temperature range: +20°C to +55°- Refrigerant: R134a (CFC-free)- Weight: 45 kg- Noise level: 70 dB(A) at 1 m distance
with maximum air output
Output signals(micro controller functions)- Required and alarm temperature can be
set per potentiometer- Alarm output per relay (normally openor closed)- Floating door contact switch as normally
closed- Connectable test mode
Material- Enclosure: stainless steel- Front panel: aluminium 3mm
Finish / Colour- Front panel, powder-coated, textured,
RAL 7035 light grey- Handles, powder-coated, textured,
RAL 5008 grey-blue
Supply schedule1 Cooling unit1 Mains supply cableOperating instructions
How supplied- In batches
Please note- Additional installation set is necessary.
Please ask.
19” Cooling unit, 6 HU 1000 W
W H D HU/U w h d kg Model Order no. UP
482,6 265,9 570 03.032.300.1 1 unit
LUF20002
LUF00213
3.13
T H E R M A L M A N A G E M E N T
Service-free operation with patentedconstruction without filter
Automatic condensation vaporization
For adding-on on the rear panel, reardoor or side panel of a cabinet
Lowered installation possible
No loss of 19” installation space
Temperature control with micro controller
CFC-free refrigerant R 134a
No danger to electronics with dustdeposits and splash water
Uniform temperature distribution in thecabinet
Weight
- 39 kg
Degree of protection- IP 54
Approvals- CE label
Technical data
Electrical supply values
(supply in the terminal strip)- Nominal voltage: 230 V- Nominal frequency: 50 Hz- Nominal current: 2.8 A- Max. starting current: 12.7 A- Power consumption: 660 W
Power data- Effective cooling output L35W35: 820 W- Maximum cabinet air flow 180 m3/h,
speed controlled- Maximum cabinet air flow 360 m3/h,
speed controlled- Temperature range: +20°C to +55°- Refrigerant: R134a (CFC-free)- Noise level: 65 dB(A) at 1 m distance
with maximum air output
Output signals(micro controller functions)- Required and alarm temperature can be
set per potentiometer- Alarm output per relay (normally openor closed)- Floating door contact switch as normally
closed (24 VDC)- Connectable test mode
Material- Enclosure: sheet steel- Front panel: aluminium 3mm
Finish- Enclosure, powder-coated, textured
RAL 7035 light grey
Supply schedule1 Cooling unitOperating instructions
How supplied- In batches
Cooling unit add-on and installation, 820 W
W H D HU/U w h d kg Model Order no. UP
395 980 135 03.032.302.1 1 unitLUF20016
LUF20014
T H E R M A L M A N A G E M E N T
3.14
Service-free operation with patentedconstruction without filter
Automatic condensation vaporization
For adding-on on the rear panel, reardoor or side panel of a cabinet
Lowered installation possible
No loss of 19” installation space
Temperature control with micro controller
CFC-free refrigerant R 134a
No danger to electronics with dustdeposits and splash water
Uniform temperature distribution in thecabinet
Weight- 50 kg
Degree of protection- IP 54
Approvals- CE label
Technical data
Electrical supply values(supply in the terminal strip)- Nominal voltage: 230 V- Nominal frequency: 50 Hz- Nominal current: 3.8 A- Max. starting current: 16 A- Power consumption: 720 W
Power data- Effective cooling output L35W35: 1400 W- Maximum cabinet air flow 250 m3/h,
speed controlled- Maximum cabinet air flow 430 m3/h,
speed controlled- Temperature range: +20°C to +55°- Refrigerant: R134a (CFC-free)- Noise level: 65 dB(A) at 1 m distance
with maximum air output
Output signals(micro controller functions)- Required and alarm temperature can be
set per potentiometer- Alarm output per relay (normally openor closed)- Floating door contact switch as normally
closed (24 VDC)- Connectable test mode
Material- Enclosure: sheet steel- Front panel: aluminium 3mm
Finish- Enclosure, powder-coated, textured
RAL 7035 light grey
Supply schedule1 Cooling unitOperating instructions
How supplied- In batches
Cooling unit add-on and installation, 1400 W
LUF20017
LUF20014
W H D HU/U w h d kg Model Order no. UP
395 1550 135 03.032.304.1 1 unit
See also: the current
Network Special Catalogue!Where you will find more products:
• 19” Rack systems
• Free-standing and wall cabinets
• TFT Drawers
• KVM Switches
• UPS Solutions
• RMS-System
• Thermal management
3TecorasOutdoor 3.13 to 3.18
3.15
T H E R M A L M A N A G E M E N T
T H E R M A L M A N A G E M E N T
3.16
The permanent increase of heat
dissipation in electronic componentsand the higher packaging density ofthe equipment caused special re-quirements for thermal manage-ment in our enclosures. Knürr
established a climate competencecenter to propose our customer thebest solutions in thermal manage-ment.
Modularity- Adjustment to various tempe-
rature conditions through themechanical and electricalcompatibility of heat exchan-gers and cooling devices- Interface for alarm monitoring
and external sensors
Complete Product RangeComplete product range ist thebest condition to to fulfill allcustomer specification- K-HEX, Knürr Heat Exchanger- HEC, Heat Exchanger Cabinet- ACUR, Air Conditioning Unit- Filter Fan- Heater- Controller Board- Membrane Filter
Climatic chamber- Inter size: 3,0x3,0x3,0 m3
- Door size: 1,15x2,45 m2
- Temperature -45 ... +60°Crange:- Humidity range: 10 ... 95%
(at 10 ... 40°C)- Access for forklift truck
Measurement instruments/documentationData logger up to 80 chanels:- Temperature- Voltage- Current
- Revolutions
Measurement instruments:- Relative humidity- Velocity- PressureData export in all usually formats
4
3
2
1
Tecoras Thermal ManagementStrong points
TEC00087
TEC002793TEC000061
TEC200814
3.17
T H E R M A L M A N A G E M E N T
Thermal design/CFDKnürr used several calculationtool to design the right thermalsotution.
The most powerful software isthe Computational FluidDynamics (CFD) program tocalculate temperature profilesand air flow velocities beforeprototyping.
As a service Knürr offers simula-tion reports and designed thethermal solution exact accordingthe specification.
Smoke TextSmoke visualize air flow.
Zones with low air flow becomevisible. These zones have risks ofhot spot. To avoid hot spots amodification of the configurationare proposed.
Acoustic noise emissionIn house semi-anchoic test floor
Acoustic-Measurement of airbor-ne noice according ISO 7779
Thermal chamber and acoustictest floor are next to each other.Knürr adjust the contrary specifi-cation requirements of lowairborne noise and high coolingperformance on an optimum way.
Acoustic noise absorberKnürr cabinets achieve very lowlevels of airborne noise emission.
Knürr used special designednoise absorber for low aousticnoise cabinets. This allows tooperate cabinets in areas withspecial aoustic noise limits.
8
7
6
5
Tecoras Thermal ManagementStrong points
TEC200805 TEC200726
TEC200737
TEC800018
T H E R M A L M A N A G E M E N T
3.18
High-capacity, compact air-to-air heatexchanger for door installation inTECORAS outdoor cabinets
Degree of protection- IP 55
Approvals- CE- UL approval- EN 60 950
Principle- Air-to-air heat exchanger with freelyprogrammable micro processor control- Countercurrent heat exchanger of epoxy
coated aluminium with extruded surface- Direct mounting on the inside of thedoor, Identical mounting principle anduniform screwing conditions for allthermal components- IP 55 interface between heat exchanger
and Tecoras door registered for patent- Air outlet grills, 90° oriented, no
thermal short circuit in the external air- From 163 mm installation depth, extru-
sion frame design and screw-free cover- Internal temperature-dependent fan
speed control guarantees optimal inter-nal cabinet temperature, maximumlifecycle and minimum noise emission- Filterless system, consequently, simple
cleaning is possible- Hidden cable entry on hinge side, no
cable and plug in the useful space of thecabinet- One variant for left and right door- Fan exchange in the internal andexternal circuit without dismounting theheat exchanger from the door- Individual fuse protection for eachfan on the control board, prefusingrequired- Customer-specific adaptations possible
with platform design
Technical data- Supply voltage, 48 VDC (optional 24 VDC)- Protection rating, IP 55 internal circuit /external circuit- Sound pressure level. 55 dB (A) at adistance of 1 m in accordance withISO 7779, in the built-in cabinet up to85 W/K
Material- Enclosure of aluminium, 1.5 mm,partially with extruded aluminium-Heat exchanger of 0.25 mm aluminium- Silicon-free seals
Supply schedule1 Heat exchanger1 Operating instructions
How supplied- Fully assembled
Tecoras Air-to-air heat exchanger (K-HEX)
W H D W/K V A Model Order no. UP
465 888 102 (118) 65 48 10 K-HEX 65 01.920.500.0 1 unit
465 1066 147 (163) 85 48 6 K-HEX 85 01.920.603.0 1 unit
565 1600 147 (163) 145 48 20 H-HEX 145 01.920.607.0 1 unit
565 1155 147 (163) 150 48 20 K-HEX 150 01.920.608.0 1 unit
TEC20062
See also: the current
Network Special Catalogue!Where you will find more products:
• 19” Rack systems
• Free-standing and wall cabinets
• TFT Drawers
• KVM Switches
• UPS Solutions
• RMS-System
• Thermal management
3.19
T H E R M A L M A N A G E M E N T
High-capacity, compact cooling unit fordoor installation in TECORAS outdoorcabinets
Approvals- CE- UL approval
Principle- High-performance cooling unit with
roating piston compressor- CFC-free referigerant, R 134a- Safe condensation dissipation to theoutside- Direct mounting on the inside of thedoor, Identical mounting principle anduniform screwing conditions for allthermal components- IP 55 interface between heat exchanger
and Tecoras door registered for patent- Air outlet grills, 90° oriented, no
thermal short circuit in the external air- Adjustable air-break panel for minimi-
zing thermal short circuit in the internalcircuit- Adjustable internal cabinet temperatureguarantees optimal internal cabinettemperature, maximum lifecycle andminimum noise emission- Equipment failure alarm with adjustable
alarm temperature (internal cabinettemperature)- Filter-free system, easy cleaning is
consequently possible- Cable entry offset to the hinge side, no
cable and plug in the useful space of thecabinet- Test switch on the control board- One variant for left and right door- Fan exchange in the internal andexternal circuit without taking thecooling unit from the door
Technical data- Output data for cooling unit built into
Tecoras cabinet, determined in accor-dance with DIN 3168, without moisturetransport in the control cabinet- Supply voltage, 230 VDC / 120 VAC,50 Hz / 60 Hz- Continuous use temperature up to 52°C- Protection rating, IP 55, internal
circuit/external circuit- Noise pressure level, 55 dB (A) at adistance of 1 m in accordance withISO 7779, mounted cabinet up to 1800 W
Material- Enclosure of aluminium, 1.5 mm
Supply schedule1 Cooling unit1 Connection cable for AC1 Plug for operation without door contact
switch1 Operating instructions
How supplied- In fully assembled
Tecoras Cooling unit (ACU R)
TEC20060
(W) W H D (V) (Hz) (A) (A) (W) Model Order no. UP
380 466 326 114 (130) 230 50/60 1,5 3,3 320 ACU R 400 230 V/AC 01.920.912.0
800 466 888 157 (172) 230 50/60 2,4 11,5 550 ACU R 800 230 V/AC 01.920.900.0
800 466 888 157 (172) 120 50/60 4,8 23,0 550 ACU R 800 115 V/AC 01.920.901.0
1200 466 1066 157 (172) 230 50/60 4,5 15,0 800 ACU R 1200 230 V/AC 01.920.904.0
1200 466 1066 157 (172) 120 50/60 9,0 30,0 800 ACU R 1200 115 V/AC 01.920.905.0
1800 466 1066 157 (172) 230 50/60 5,0 22,0 1200 ACU R 1800 230 V/AC 01.920.906.0
1800 466 1066 157 (172) 120 50/60 10,0 44,0 1200 ACU R 1800 115 V/AC 01.920.907.0
2700 566 1600 157 (172) 230 50/60 8,0 30,0 1700 ACU R 2700 230 V/AC 01.920.910.0
Technical dataSupply voltage 230 VAC/50(60) Hz, Axialfan: air throughput 35 m3/h with 150 W,from 300 W 108 m3/h, 950 W 160 m3/h,Thermostat: temperature setting from0 to 60° CHeating element protection with tempera-ture monitor in the event of fan failureProtection rating IP 20
Supply schedule1 Heating fan, 230 VAC/50(60) Hz1 Thermostat with contact break1 Connecting cable, 1,5 mm2,1,5 m cable length1 Mounting panelMounting material
How suppliedFully assembled
Heating Unit
TEC00335
W H D W/K V A Model Order no. UP
108 85 139 150 01.910.900.9 1 unit
135 85 182 300 01.910.901.9 1 unit
135 85 182 400 01.910.902.9 1 unit
145 85 240 600 01.910.903.9 1 unit
145 100 200 950 01.910.908.9 1 unit
3.20
Rapid service
Express Articles
Fast express delivery service,seamless ordering system,
attractive prices and a market–
oriented offer - that’s Knürr
efficiency!
Every express article that is
correspondingly identifed in
this catelogue leaves our
European central stores 24
hours after your order is
received: qualitative high-
grade, standardised solutions,
with which you are always
decisively ahead of the compe-tition.
Our sales offices are also avai-lable for you worldwide, where
competent technicians andsales engineers will personal-ly take care of your specialrequirements.
Why not use these advantagesto your own benefit.
Express articles
in 24 hours ex plant:
With Knürr you are always
ahead of the competition
4Power supplySystemsPower Supplies/DC-UPS 4.2 to 4.10
4.1
P O W E R S U P P LY S Y S T E M S
DC-UPSStrong Points 4.2
Products 4.4
Distribution BoxProducts 4.10
4.2
P O W E R S U P P LY S Y S T E M S
Temperature controlled charging
Optimal charge current
adaptation due to battery
temperature measurement,maximum permissible constant
current for minimum battery
charging time
Monitoring
Monitoring of Rectifier module,Battery tests, registering andlinking of connected monitoringsensor systems
Communication
Transmission of analysis andalarm data via serial and binary
interfaceDisplay of operating and alarmstates via LEDs and LC display
8
7
6Modular Design
Configuration and equipping tosuit requirements in case of:Redundancy and easy futureupgrade possible
High power density
Up to 7,2 kW with a dimension of19”x3Ux300 mm (WxHxD)
Hot SwapFast on line replacement ofRectifier and Battery Control-Unitwithout system shutdown
Wide input voltage rangeOperate in a variety of AC supplyconditions
Wide area of operation
Usable for all indoor and outdoorapplications; tested cold start
routines and ready to operate at
high ambient temperature
5
4
3
2
1
Rectifier/DC Power and Backup SystemsStrong points
TEC200851 TEC000136
TEC200882
TEC000118
4.3
P O W E R S U P P LY S Y S T E M S
The power system
Consists of the following individualcomponents:- 1 to 5 (6 with 1200 W) piece of
200 W, 750 W or 1200 W rectifiermodules- Charge monitor module- Backplane for mounting theindividual modules- 19” Modular chassis
Height 3 HU (1 HU = 44.45 mm),depth 285 mm (200 W rectifier)or depth 340 mm (750 W rectifier)
Various freely-selectable combina-tion options can be designed withthe modular concept.The integrated charge controllermonitors the batteries in the UPSoperation and ensures optimal bat-tery charging.Using connected sensors anddepending on the requirements, itadditionally monitors the environ-mental conditions in the rack as wellas monitoring the power modulesand controlling battery tests.If an uninterruptible power supplyfunctionality is not required, thepower supply can also be operatedwithout batteries and chargecontroller.Depending on the number of PSUmodules, output power of up to1000 W, 3750 W or 7200 W, can berealized in each 200, 750 or 1200 Wstage.With output of up to 600 W or
2250 W (3 modules), a DC distributorcan be integrated in the modular
chassis.
TEC00056
DC Backup SystemsTechnical data, power system with battery buffer
P O W E R S U P P LY S Y S T E M S
4.4
Power System, MAXI DC UPS 750 W
Technical dataOutput power 750 W with 230 V
AC supply500 W with 115 V ACsupply
Characteristic Current/voltagewith temperature-regulated adaption
Ventilation With convectionforced cooling withTu › 35º C
Operating temp. –10° C to +60° CrangeStorage temp. –40° C to +85° CrangeHumidity 30% to 95% (no
dewfall)Input voltage 100 V AC …240 V ACrange nominalEfficiency 90% at full load
(Ue = 240 V)Power factor › 0.9 in acc. with(with full load) EN 61000-3-2Input current 25 A with 265 V AClimitOutput power 750 W
(TU =25° C)Convection750 W (TU = 50° C)Fan(VL = 1.5 m/s)
Output voltage 48 V DCSetting range of the 42 V DC to 585 Voutput voltage DC, short circuit-
proofStandards EN 55022B,
EN 61000-3-2,EN 61000-4 part 2,3, 4, 5 level 3,ETS 300 339,ETS 300 342-2,GSM 11.22,EN 60950, VDE 0160
MTBF ›100,000 hrsDimensions Width 15 HP,
Height 3 HU,Depth 295 mm
Power System, MIDI DC UPS 200 W
Technical dataOutput power 200 W regulated at
115/230 V AC(230 V AC with con-vective cooling)
Regulation Current-regulated(with temperature-regulated adaption)
Efficiency › 85% at full loadPower factor › 0.8 in acc. with
EN 6100-3-2Ventilation ConvectionDerating From Tu 35° COperating temp. 0°C to +60° Crange (switch-off at
› 60° C)Storage temp. -40° C to +85° CrangeHumidity 30% to 95%
(no condensationmoisture)
Voltage range 100 V AC … 240 V ACInput current 5 AlimitOutput voltage 48 V DCStandards EN 55022B,
EN 61000-3-2,EN 6100-4 part 2-5,EN 50081-1,EN 50082-2,EN 60950,VDE 0160
MTBF › 100,000 hrsDimensions Width 15 HP
Height 3 HUDepth 220 mm
HEI00400
HEI00402
4.5
P O W E R S U P P LY S Y S T E M S
Power System, MAXI II 1200 W
Technical dataOutput power 1200 W (25A @ 48 V)
at 230 VAC supplyCharacteristic Power/Voltage with
temperaturecontrolled adaptation
Ventilation Temperature con-trolled, highreliability fan
Operating temp. –10° C to +70° Crange (Output current is
derated above 50° C)Storage temp. –40° C to +85° CrangeHumidity 30% to 95%
(no moisturecondensation)
Input voltage 90 VAC ... 300 VACrange (220/240 V, 50/60 Hz
nominal)
Efficiency 90% (at 50 - 100%output current)
Power factor › 0,99 (at 50 - 100%output current)
Output power 1200 W (TU ‹ 50° C)Output voltage 48 VDCSetting range 43.2 V to 58 VStandards EN 55022B,
EN 61000-3-2,EN 61000-4 part2-5, EN 50081-1,EN 50082-2,EN 60950, VDE 0160
MTBF ›100,000 hrsDimensions Width 13 HP,
Height 3 HU,Depth 280 mm
Power System, MIDI 200 - 1000 Wfor external distribution
Dimension- Width 19”- Height 3 U with modular chassis- Depth 285 mm
Supply schedule1 Modular chassis, 3 HU equipped with- 1...5 PSU module 200 watt- Charge controller BCU
Please noteBattery configuration possible to suitrequirements, on separate battery tray.We are happy to be able to offer you theappropriate batteries for your requiredbackup times.
TEC20086
W H D P(W) h d kg Model Order no. UP
200 7,0 06.104.102.1 1 unit
400 8,1 06.104.202.1 1 unit
600 9,2 06.104.302.1 1 unit
800 10,3 06.104.402.1 1 unit
1000 11,4 06.104.502.1 1 unit
HEI00412
Power System, MIDI 200 - 600 Wwith integrated distribution
Dimension- Width 19”- Height 3 U- Depth 285 mm
Supply schedule1 Modular chassis, 3 HU equipped with
backplane, with- 1...3 PSU module 200 watt- Charge controller BCU- 1 DC distribution 3 HU with output
terminal and fuse protection
Please noteBattery configuration possible to suitrequirements, on separate battery tray.We are happy to be able to offer you theappropriate batteries for your requiredbackup times.
W H D P(W) h d kg Model Order no. UP
200 7,8 06.104.132.1 1 unit
400 9,0 06.104.232.1 1 unit
600 10,2 06.104.332.1 1 unit
HEI00414
P O W E R S U P P LY S Y S T E M S
4.6
Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depth
HU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weight
P (W) = Output power, * = Backup time in minutes, ** = Backup time in hours
Final digit of order number:
.1 = RAL 7035
Power System, MIDI Compact I... IV DC UPS 200 - 600 Wwith integrated battery pack
19” DC UPS MIDI Compact I, 6 HUwith integrated battery pack
Dimensions- Width 19”- Height 6 HU- Depth 285 mm
Supply schedule1 Modular chassis, 6 HU equipped with- 1…3 Recitfier module, 200 W- Charge controller, 9 HP (without dis-play/ RS-232 interface)- Integrated battery pack, 13 Ah- Integrated DC distribution with outputfuses
19” DC UPS MIDI Compact II, 6 HU
Supply schedule same as Compact I,but with- Integrated DC distribution with circuit
breakers
19” DC UPS MIDI Compact III, 6 HUSupply schedule same as Compact I,but with- Charge controller, 9 HP with LC display/
RS-232 interface
19” DC UPS MIDI Compact IV, 6 HUSupply schedule same as Compact I,but with- Charge controller, 9 HP with LC display/
RS-232 interface- Integrated DC distribution with circuit
breakers
HEI00402
min* P(W) kg Model Order no. UP
180 200 31.0 UPS MIDI Compact I 06.104.111.1 1 unit
90 400 32.5 UPS MIDI Compact I 06.104.211.1 1 unit
45 600 34.0 UPS MIDI Compact I 06.104.311.1 1 unit
180 200 31.0 UPS MIDI Compact I 06.104.121.1 1 unit
90 400 32.5 UPS MIDI Compact II 06.104.221.1 1 unit
45 600 34.0 UPS MIDI Compact II 06.104.321.1 1 unit
180 200 31.0 UPS MIDI Compact III 06.104.112.1 1 unit
90 400 32.5 UPS MIDI Compact III 06.104.212.1 1 unit
45 600 34.0 UPS MIDI Compact III 06.104.312.1 1 unit
180 200 31.0 UPS MIDI Compact IV 06.104.122.1 1 unit
90 400 32.5 UPS MIDI Compact IV 06.104.222.1 1 unit
45 600 34.0 UPS MIDI Compact IV 06.104.322.1 1 unit
Power System, MIDI compact DC UPS 200 - 400 WUPS with integrated battery pack
Dimension- Width 19”- Height 3 U with modular chassis- Depth 285 mm
Supply schedule1 Modular chassis, 3 U equipped with- 1...2 Power supply module (PSU) withoutput power of 200 W each- Charge controller 9 HP- Integrated battery pack 4 Ah- Integrated DC distribution with circuit
breakers
min* P(W) kg Model Order no. UP
30 200 14,8 06.104.100.1 1 unit
10 400 16,0 06.104.200.1 1 unit
HEI00416
4.7
P O W E R S U P P LY S Y S T E M S
Power System, MAXI 750 - 3750 Wwith external distribution
Dimension- Width 19”- Height 7 U- Depth 340 mm
Supply schedule1 Modular chassis, 3 U with backplane,
with- 1...5 PSU module 750 watt- Charge controller BCU
1 Fan unit 1 U1 AC / DC Distribution, 3 U with
- AC Input protection- Service sockets with RCCB- DC Output terminal with fuse protection
Please noteBattery configuration possible to suitrequirements, on separate battery tray.We are happy to be able to offer you theappropriate batteries for your requiredbackup times.
W H D P(W) h d kg Model Order no. UP
750 17,1 06.103.000.1 1 unit
1500 19,2 06.103.010.1 1 unit
2250 21,3 06.103.020.1 1 unit
3000 23,4 06.103.030.1 1 unit
3750 25,5 06.103.040.1 1 unit
HEI00400
Power System, MAXI 750 - 2250 Wwith integrated distribution
Dimension- Width 19”- Height 3 U- Depth 340 mm
Supply schedule1 Modular chassis, 3 U with backplane,
equipped with- 1...3 PSU module 750 watt- Charge controller BCU
1 DC Distribution, 3 U with outputterminal and fuse protection
Please noteBattery configuration possible to suitrequirements, on separate battery tray.We are happy to be able to offer you theappropriate batteries for your requiredbackup times.
W H D P(W) h d kg Model Order no. UP
750 9,4 06.103.001.1 1 unit
1500 11,5 06.103.011.1 1 unit
2250 13,6 06.103.021.1 1 unit
HEI00409
Power System, MAXI compact DC UPS 750 - 2250 Wwith integrated battery pack
Dimension- Width 19”- Height 6 U- Depth 340 mm
Supply schedule1 Modular chassis, 6 U equipped withbackplane, with- 1...3 PSU module 750 watt- Charge controller BCU
1 DC Distribution, 3 U with outputterminals with fuse protection
How supplied- In batches
min* W H D P(W) h d kg Model Order no. UP
40 750 32,9 06.103.002.1 1 unit
13 1500 35,0 06.103.012.1 1 unit
8 2250 37,1 06.103.022.1 1 unit
TEC20089
P O W E R S U P P LY S Y S T E M S
4.8
Power System, MAXI II 1200 - 7200 Wwith external distribution
Dimension- Width 19”- Height 6 U- Depth 300 mm
Supply schedule1 Modular chassis, 3 U with backplane,
with- 1...6 PSU module 1200 watt- Charge controller BCU
1 AC / DC Distribution, 3 U with- AC Input protection- Service sockets with FI- DC Output terminal with fuse protection
How supplied- In batches
W H D P(W) h d kg Model Order no. UP
1200 17,1 03.013.500.1 1 unit
2400 19,2 03.013.501.1 1 unit
3600 21,3 03.013.502.1 1 unit
4800 23,4 03.013.503.1 1 unit
6000 25,5 03.013.504.1 1 unit
7200 27,6 03.013.505.1 1 unit
TEC20086
Power System, MAXI II 1200 - 3600 Wwith integrated distribution
Dimension- Width 19”- Height 3 U- Depth 300 mm
Supply schedule1 Modular chassis, 3 U with backplane,
equipped with- 1...3 PSU module 1200 watt- Charge controller BCU
1 DC Distribution, 3 U with outputterminal and fuse protection
Please noteBattery configuration possible to suitrequirements, on separate battery tray.We are happy to be able to offer you theappropriate batteries for your requiredbackup times.
How supplied- In batches
W H D P(W) h d kg Model Order no. UP
1200 9,4 03.013.510.1 1 unit
2400 11,5 03.013.511.1 1 unit
3600 13,6 03.013.512.1 1 unit
TEC20091
Power System, MAXI compact II DC UPS 1200 - 3600 Wwith integrated battery pack
Dimension- Width 19”- Height 6 U- Depth 300 mm
Supply schedule1 Modular chassis, 3 U with backplane,
equipped with- 1...3 PSU module 1200 watt- Charge controller BCU
1 Integrated battery pack 13 Ah1 DC distribution, 3 V with output
terminals with fuse protection
How supplied- In batches
min* W H D P(W) h d kg Model Order no. UP
18 1200 32,9 03.013.520.1 1 unit
7 2400 35,0 03.013.521.1 1 unit
3 3600 37,1 03.013.522.1 1 unit
TEC20090
4.9
P O W E R S U P P LY S Y S T E M S
Power System, MINI DC UPS 25W1 U with integrated battery pack
Dimension- Width 19”- Height 1 U- Depth 225 mm
Supply schedulePower supply 48 V / 25 wattIntegrated battery pack for 4 hoursbackup time DC Output and signaloutputs via SUB-D socketAlarm messages for- Mains voltage- Charge regulator monitoring- Battery partial discharge- Battery deep discharge
W H D P(W) h d kg Model Order no. UP
25 4 5 06.104.900.1 1 unit
HEI00404
P O W E R S U P P LY S Y S T E M S
4.10
Distribution Box
W H D Model Order no. UP
19” 3 HU 150 mm Pull-in 03.013.385.1 1 unit
19” 3 HU 158 mm Fixed installation 03.013.470.1 1 unit
WW HH DD MMooddeell OOrrddeerr nnoo.. UUPP
03.013.386.1 1 unit
- For mounting installation engineering DINrail components such as fuses, terminals,relays etc.- When installed, the mounting level can bepulled out to the front and interlocked, thusconsiderably facilitating the wiring of indivi-dual components Not with “fixed installation” model- Installation space for up to 22 installationdevices of 18 mm width each- Mounting of the TS35 DIN rail on severallevels due to simple plug-in connectionNot with “fixed installation model”- "Snap-in" mounting of DIN rail components - Free access to protective earth and neutral
conductor rail from the front- Different positioning options prepared for N
and PE railsNot with “fixed installation” model
- Cable entry at the back via double brushstrip (optional via bushing panel)- Internal strain relief and thus accessiblefrom the front- Front labelling above and below the installa-
tion space- Power uses for power distribution at 230 V
AC, but also in the low voltage range (e.g. 48V DC)On request: can be delivered ready equippedand cabledOther options and models available onrequest- 19" Chassis, 3 HU, depth 150 mm
Material / Finish- Covers, powder-coated
RAL 7035 light-grey, textured- Main unit, sheet steel, zinc passivated
Supply schedule1 Distribution boxIncluding N and PE rails, cable entry,strain relief, empty panel covers andearthing kit
How suppliedFully assembled
HEI00379
HEI00234
Distribution Box Bushing Panel
Alternative to cable entry via brush strip withmounting the distribution box in open racks
Material / FinishSheet steel, zinc passivated
Supply schedule1 Cable entry panel11 Bushing socketsMounting material
Dimensions in mm: W = Width HU = Standard height unitH = Height UP = Unit of packagingD = Depth kg = Weighth = Installation heightd = Useful depth = Express Article
5SystemMonitoringRMScompact 5.2 to 5.6
5.1
S Y S T E M M O N I T O R I N G
System
Monitoring
RMScompactStrong points 5.2
Products 5.4
Accessories19” Adapter Front Panel 5.4
Temperature Sensor 5.5
Humidity Sensor 5.5
Smoke Sensor 5.5
Door Contact Sensor 5.5
Water Sensor 5.6
Shock Sensor 5.6
Infrared Detector 5.6
RMS20013
Until now, system monitoring options were limited to active components.Now, with SNMP management systems, parameters such as data emer-gence, error rate, equipment configuration and, of course, downtime ofindividual connections or hardware components are all monitored. But thecauses for such downtimes remain for the most part unclear, and are onlyfirst realised on-site, i.e. in the server or network rack or cabinet.Observance of the required environmental parameters is, however, ofenormous importance for the fault-free operation of high-grade compo-nents. Inadmissible fluctuations in temperature, humidity or power supplyare frequently the cause of hardware defects, therefore constant automaticmonitoring is a fundamental requirement for securing operational functio-nality. With the rack monitoring systems available on the market today,these parameters and other factors can be recorded, and can often bepassed directly on to a superordinate management system. However,recording of conditions alone is often not enough to combat damage as thetime from occurance of a critical condition to initiation of combatative mea-sures, particularly with larger network environments, is often quite limited.In such cases it is extremely helpful if the monitoring system can automati-cally implement constructive measures (e. g. additional active fans). Whensuch incidents occur, the equipment should at least be able to immediatelysend a report (trap) to the management system, which for example, willthen notify those responsible for the network via e-mail or pager. Thisenables a sufficiently short reaction time and a swift location of the faultlocation and its subsequent elimination.With the option of connecting additional sensors like smoke detectors, doorcontacts etc., not only enclosures but entire rooms or building sections canbe monitored. In this way all environmental parameters of a computer cent-re can be easily recorded and evaluated.
Please address any questions to: RMS-COMPACT@KNUERR.COM
RMS compact
The security system fornetwork and server racksand computer centres
5.2
S Y S T E M M O N I T O R I N G
5.3
S Y S T E M M O N I T O R I N G
The main tasks that amodern rack monitoringsystem must perform:
• Guarantee a disturbance-free operation• Provide early detection of fault-provoking influences• Record all such incidents - Simplify service implementation with
automatic monitoring• Activate counteractive measures in the event of malfunctioning• Centrally control the conditions of material in use (filters, fill levels,meter readings, inspection intervals etc.)
RMS20026
S Y S T E M M O N I T O R I N G
5.4
RMS20013
Description- Compact design - Zero unit solution(to be mounted outside the 19” installa-tion area)- 19” Installation with 1HU adapter frontpanel (optional)- Safe clamping of all connected cables
with integrated cable clamping bracket - Cost-effective, tidy installation with Plug
& Play concept- Convenient cabling with plug-in contacts- TCP/IP Connection via Ethernet(10 Base T)- Configuration via SNMP, Telnet and web
browser- Serial configuration via terminal emu-lation (e.g.. hyper terminal,...)- Telnet and web access are passwordprotected- Viewer and configuration software(free-of charge in supply schedule)- Freely programmable filter system(Boolean logic) for implementing anykind of alarm conditions - Compatible with current networkmanagement systems – HPOpenView,Cabletron Spectrum, Castlerock, IBMNetview, IBM Tivoli, MG-Soft, CompaqInsight Manager, SUN NetManager, etc.- Sensors for monitoring all current envi-
ronment influences (optional)- Monitored internal voltage supply for
sensor systems (no additional powersupply required)- Alarm via LED, relay or network mana-gement
- Firmware upgrade via serial interface orTFTP- Integration of external devices via V.24possible (on request)
Technical data- 2 Sensor inputs for temperature
sensors or temperature/humiditysensors- 8 Digital inputs, can be configured with
software- 8 Outputs 12VDC for voltage-
supply of external sensor system- 3 Digital outputs (relay, max. 5A with
230VAC)- Voltage supply: 100 – 240 VAC- Operating voltage: 12VDC
Approvals- CE Label in accordance withlow voltage guideline 73/23/EWG, EMCguideline 89/336/EWG
Colour- RAL 7021 dark-grey
Supply schedule1 RMS compact1 Power supply1 Mounting bracket1 Power supply mounting bracket1 Serial cable1 CD ROM (with manual, viewer and
configuration software, MIB file)
How suppliedFlat-packed kit
RMS compact
RMS compact
W H D Model Order no. UP
280 40 140 RMS compact 06.108.100.8 1 set
RMS20015
RMS20014
19” Adapter Front Panel
Description- Enables 19“ installation in racks
and enclosures- Prepared for simple and safe mountingof the RMS compact
Material- Sheet steel 1.5 mm
Finish- Powder-coated RAL 7021
Dark-grey
Supply schedule1 19“ Adapter front panel, 1HU
19” Adapter front panel
W H D Model Order no. UP
19” 44 1 06.108.130.8 1 unit
Dimensions in mm: W = Width HU = Standard height unitH = Height UP = Unit of packagingD = Depth kg = Weighth = Installation heightd = Useful depth = Express Article
5.5
S Y S T E M M O N I T O R I N G
RMS20019 (similar to illustration)
Temperature/Humidity Sensor
Description- Insensitive to faults - No additional voltage supply required- Standard cable length, 4 m- Recalibration of the sensor not necessaryCalibration possible via configurationsoftware
Technical data- Temperature measuring range, 0-60°C- Accuracy: +/- 5%- Air measuring range 30-90°C- Accuracy: +/- 5%
Supply schedule1 Sensor with 4 m connection cable1 Mounting set
Temperature / air humidity sensor
Model Order no. UP
06.108.112.9 1 unit
RMS20005
Smoke Detector
Description- Visual smoke detector
German insurance accreditation (VdS)- For early detection of fire with smoke
build-up- Voltage supply via RMS compact- Standard cable length 4 m
Technical data- Operates from -20°C to +75°C
Supply schedule1 Sensor with 4 m connection cable1 Mounting set
Smoke detector
W H D Model Order no. UP
Ø 90 75 06.108.111.9 1 unit
RMS20006
Door Contact Sensor
Description- Magnet bridge sensor functions withevery magnetic conductive material (nospecial opposing object required)- Can also be used for monitoring sidepanels and roof- Standard cable length, 4 m
Technical data- Operates from -20°C to +70°C- Switching voltage, max. 200VDC- Switching current, max. 500mA
Supply schedule1 Sensor with 4 m connection cable1 Mounting set
Door contact sensor
W H D Model Order no. UP
06.108.115.9 1 unit
RMS20019 (similar to illustration)
Temperature Sensor
Description- Insensitive to faults - No additional voltage supply required- Standard cable length, 4 m- Recalibration of the sensor not necessaryCalibration possible via configurationsoftware
Technical data- Temperature measuring range, 0-60°C- Accuracy: +/- 5%
Supply schedule1 Sensor with 4 m connection cable1 Mounting set
Temperature sensor
Model Order no. UP
06.108.110.9 1 unit
S Y S T E M M O N I T O R I N G
5.6
RMS20031
Water sensor
Description- Detection of presence water
Technical data- Operating voltage: max. 24 VDC
Supply schedule1 Sensor with 2 m connection cable1 Mounting bracket
W H D HU/U h d kg Model Order no. UP
06.108.117.9 1 unit
RMS20019
Shock sensor
Description- Detects vibrations- Protection against thievery- Reset with the Viewer-Software possible
Supply schedule1 Sensor with 4 m connection cable
W H D HU/U h d kg Model Order no. UP
06.108.113.9 1 unit
RMS20032
Passive infrared motion detector
Description- State of the art room monitoring
Technical data- German VdS-approval class A + B- Surface optics - range 2 - 16 m- Long distance optics 29 - 50 m- Curtain optics 17 - 30 m- Tamper monitoring- Digital fault evaluation- Corner or wallmounting
Supply schedule1 Sensor with 4 m connection cable1 Mounting set
W H D HU/U h d kg Model Order no. UP
06.108.114.9 1 unit
6TechnicalSection 6.2 to 6.7
6.1
T E C H N I C A L S E C T I O N
6.2
T E C H N I C A L S E C T I O N
Standards and Regulations
Protection ratings with enclosures (IP code)EN/IEC 60529
EMC Interference emission andEMC Interference immunity
EN 61000/55011/55022Protection of electronic equipment andsystems against electro-magnetic effects.The shielding protects against both theeffects of the external electro-magneticinfluence and the outward radiation ofelectro-magnetic energy.The shielding requires detailed know-howand extensive experience.
• The following should be taken intoaccount:- EMC justified construction- Highly-conductive surfaces- Material combinations with low potentialdifference- Low ohmic material connections- Seals- EMC Cable entry
Shielding measures on, for example, primusmodular chassis:
• Surface- Highly-conductive zinc passivated sheet
steel
– Shielding and optimal ventilation withsuitable perforation
– Optimal bonding of the side panels to thetop/bottom cover
– The bonding of front panel and rear panelon the modular chassis is made via theEMC spring
First SecondID Shock-hazard Foreign object ID Water protectiondigit protection protection digit
0 No special protection 0 No specialprotection
1 Against large-area Large foreign 1 Against verticallybody surfaces objects falling water
Diameter› 50 mm
2 Against finger or Medium-sized 2 Against diagonallysimilar size objects foreign objects falling water
Diameter (up to 15” vertical› 12 mm deviation)
3 Against tools, Small foreign 3 Against spalsh waterwires and similar objects (any direction,objects with dia. of Diameter up to 60º deviation› 2.5 mm › 2.5 mm from the vertical)
4 Against tools, Grainy foreign 4 Against spalsh waterwires and similar objects from all directionsobjects with dia. of Diameter› 1 mm › 1 mm
5 Full Dust-protected; 5 Against sprayedprotection dust deposits are from a nozzle,
permitted, but they are from all directionsnot allowed to build upand impair the function-ing of the equipment.
6 Fullprotection Dust-proof 6 Against flooding
7 Against immersion
8 Against submersion
6.3
T E C H N I C A L S E C T I O N
Heat transferVDE 0660 Part 507, process fordetermining heating(identical to IEC 890)
LUF00083
LUF00087
Determining via diagram (alternative)
P0 = k x A x (Ti – Tu) (W)
- P0 Output that can be dissipated over therack surface
- k Heat transfer coefficient ~5 W/m2 K single-skinned3 W/m2 K double-skinned1 W/m2 K double-skinned insulated
- A Effective rack surface area- Ti Internal rack temperature- Tu Envir. air temperature- ∆T = Ti - Tu (K) Temperature difference- P0 › 0 : Heat output
- P0 ‹ 0 : Heat absorption
Examplek = 5 W/m2 K (sheet steel)A = 5.38 m2
Ti = 40º CTu = 20º C
P0 = 5 x 5.38 x (40 – 20) = 538W
There are 5 heat transfer options dependingon the dissipation power available. Selectionand dimensioning are made taking the envi-ronmental conditions into account, dependingon the istallation site (IP protection, noiselevel, room size and climate conditioning etc.)
1. Over the Rack Surface
Single enclosure, all sides,stand-aloneA = 1.8xHx(W+D)+1.4xWxD
Single enclosure, for wallmountingA = 1.4xWx(H+D)+1.8xDxH
Beginning-end enclosure,stand-aloneA = 1.4xDx(H+W)+1.8xWxH
Beginning-end enclosure,for wall mountingA = 1.4xHx(W+D)+1,4xWxD
Centre enclosure,stand-aloneA = 1.8xWxH+1.4xWxD+DxH
Centre enclosure, for wallmountingA = 1.4xWx(H+D)+DxH
Centre enclosure for wallmounting with covered roofsurfaceA = 1.4xWxH+0.7xWxD+DxH
Enclosure configuration in accordance with IEC 890
B = SchaltschrankbreiteH = SchaltschrankhöheT = Schaltschranktiefe
Calculation of the effective rack surface
P0 (W)
A (m2)
∆T
T E C H N I C A L S E C T I O N
6.4
2. Direct Heat Exchange with Fans
Calculation of the required airflow volume
V = f (h) x Pv / ∆T (m3/h)
- V Required airflow volume- PV Dissipation power in the rack- Ti Internal rack temperature- Tu Envir. air temperature- ∆ T = Ti - Tu (K) Temperature
difference, Ti › Tu
- fh Auxiliary factor
ExamplePV = 1500 WTi = 35º CTu = 25º Ch = 1000 m
V = 3.5 x 1500/(35 – 25) = 525 m3/h
LUF00075 LUF00077
LUF00088
Determining via diagram
3. Heat Exchanger, Air / Air
Calculation of the required cooling output
QK = Pv – P0 (W)
- QK Required cooling output of the heatexchanger
- PV Dissipation power in the rack- P0 Output that can be dissipated over the
rack surface
ExamplePV = 1300 WP0 = 538 WTi = 40º CTu = 20º C (Ti › Tu)A = 5.38 m2
QK = 1300 – 538 = 762 W
LUF00080
V (m3/h)
PV (W)
∆T
Dependence h to f
h (m) f (m3k/wh)
0-100 3.1
100-250 3.2
250-500 3.3
500-750 3.4
750-1000 3.5
6.5
T E C H N I C A L S E C T I O N
i.e. the device is sufficiently dimensioned forthe above-mentioned use
LUF00089
Determining via diagram
QK = - 1200 W
4. Cooling Unit with Refrigerant
Calculation of the required cooling output
QK = Pv – P0 (W)
- QK Required cooling output of the coolingunit
- PV Dissipation power in the rack- P0 Output that can be dissipated over the
rack surface
Worth notingAs in this case Ti = Tu › Ti is possible, theheat transfer output P0 can also benegative
Examplek = 5 W/m2
K x 1A = 5.38 m2
Ti = 30º CTu = 35º CPV = 500 W
P0 = k x A x (Ti – Tu) = – 134.5 WQk = PV– P0 = 500 – (– 134.5) = 634.5W
LUF00080LUF00082
i.e. the device is sufficiently dimensioned forthe above-mentioned use
LUF00090
Determining via diagram
QK = - 800 W
Qk (W)
Tu (K)
Qk (W)
Tu (°C)
Ti
T E C H N I C A L S E C T I O N
6.6
Calculation of the required cooling output
QK = Pv – P0 (W)
- QK Required cooling output of the heatexchanger
- PV Dissipation power in the rack- P0 Output that can be dissipated over the
rack surface
Worth notingAs in this case Ti = Tu › Ti is possible, theheat transfer output P0 can also benegative
Examplek = 5 W/m2 k x 1A = 5.38 m2
PV = 1000 WTi = 30º CTu = 35º C
P0 = k x A x (Ti – Tu) = – 134.5 WQk = PV– P0 = 1000 – (– 134.5) = 1134.5W
Ti = 30º C(Tu = 35º)TW = 15º C
The environmental temperature has no influ-ence on the cooling output of the air/waterheat exchanger, but the water temperature TWdoes
LUF00255
5. Heat Exchanger, Air / Water
i.e. the device is sufficiently dimensioned forthe above-mentioned use
LUF00091
Determing via diagram
QK = - 1500 W
QK (W)
TW (°C)
6.7
T E C H N I C A L S E C T I O N
Fire behaviour
• FlammabilityUL 94, The Standard for Flammability ofPlasic Materials for Parts in Devices andApplications equates with IEC 60607,60695-11-10, 60695-11-20, ISO 9772 and9773
• Ignition Resistance UL 746A, TheStandard for Polymeric Materials is similar to IEC 60112, 60695 and 60950.
DRAHTGEFLECHT
ca.45°
DRAHTGEFLECHT
PROBE
FTI20F
100 ± 1 mm
25 ± 1 mm
45 ± 2°
10 ± 1 mm
Set-up for investigating horizontal fire behaviour and vertical fire behaviour
Horizontal fire behaviour Vertical fire behaviour
PROBE
100 ± 1 mm
20 ± 1 mm
300 ± 10 mm
6 mm max.
ca. 50 mm
BAUMWOLLE
BUNSENBRENNER
Main criteria for foammaterial: Main criteria:
HBFBurning speed not › 40 mm / min. over100 mm burn length, self-extinguishingbefore the 125 mm point
• Heat of combustion in rescue routesVDE 0108Heat of combustion in rescue routes,maximum 7 kWh/m2, with use of halogen-free light plastic-sheathed leads andcables (VDE 0250,0266) with improved firebehaviour 14 VDE kWh/m2
HF1 HF2
Reheat time 80% ‹2s ‹2s
100% ‹10s ‹10s
Afterglow time m 30s m 30s
Burning drip no permitted
• Classifications in accordance with UL 94Vertical: Six classes for materials
that are frequently used inenclosures, structure com-ponents and insulators:5VA, 5VB, V-0, V-1, V-2, HBThree classes for thin filmmaterial: VTM-0, VTM-1,VTM-2
Horizontal: Three classes for foammaterial: HF-1, HF-2, HBF
V_0 V-1 V-2
Reheat time ‹10s ‹30s ‹30s
Overall burn time ‹50s ‹250s ‹250s
Burning drip no no permitted
I N D E X
6.8
A
Access controlAccessories dart fan unit 3.10Accessories miracel EMCdouble panelled 1.27
Accessories miracel EMCsingle panelled 1.17
Accessories Outdoor Systems 2.18Accessories Outdoor Wall Case 2.27Accessories RMS 5.4Accessories smaract 19”
Compact Rack 1.42ACU Air Conditioning Unit Indoor 3.12ACU Air Conditioning Unit Outdoor 3.19
B
Battery Tray Outdoor Systems 2.18Battery Tray Outdoor Wall Case 2.27
C
Cable Entry Panel Outdoor Systems 2.20Compact Rack 1.37Connection Panel smaract 1.48, 1.49
1.51, 1.52Cooling Unit Indoor 3.12Cooling Unit Indoor 1000W 3.12Cooling Unit Indoor 1400W 3.14Cooling Unit Indoor 820W 3.13Cooling Unit Outdoor 3.19
D
dart fan unit 3.6DC-UPS 4.1Distribution Box 4.10Door Contact Sensor 5.5Door Contact Switch Outdoor Systems 2.19
E
EMC 19” Rack 1.12EMC 19” Rack doubled panelled 1.12EMC 19” Rack single panelled 1.21ETS Rack 1.31Extrusions Outdoor Systems 2.18
F
Fan unit 3.6Filter Box shielded 2.20Filter for dart fan 3.10
H
Heat Exchanger Indoor 3.10Heat Exchanger Indoor 1000W 3.10Heat Exchanger Indoor 2000W 3.11Heat Exchanger Outdoor 3.18Heating Unit Outdoor 3.20Humidity Sensor 5.5
I
Indoor systems 1.1Infrared Detector 5.6
L
Lamp Outdoor Systems 2.19
M
miracel 19” Rack 1.5miracel EMC 19” Rack 1.12miracel EMC 19”Rack doubled panelled 1.12miracel EMC 19”Rack single panelled 1.21miracel IP55 1.11Mounting Panel Outdoor Systems 2.21
O
Outdoor Systems 2.1
P
Plinth Outdoor Systems 2.20Plinth smaract 1.45Power Distribution 4.10Power Supplies 3.1Power System 1200-7200W 4.8Power System 200-1000W 4.5Power System 25W 4.9Power System 750-3750W 4.7
R
Rack Monitoring System 5.1Rear Panel smaract 1.49, 1.52RMScompact 5.1
S
Sensoric 5.5Shock Sensor 5.6“smaract 19”” Compact Rack” 1.37“smaract 19”” Enclosure EMC” 1.47“smaract 19”” Enclosure IP54” 1.50Smoke Sensor 5.5Street Cabinet 2.11
T
Tecoras Tecoras Cooling Unit 3.19Tecoras Heat Exchanger 3.18Tecoras Outdoor Cabinet 2.3Tecoras Outdoor Cabinet Add-On 2.8Tecoras Outdoor Cabinet Basic 2.7Tecoras Outdoor Cabinet Double Door 2.8Tecoras Outdoor Cabinet HEC 2.9Tecoras Outdoor Wall Case 2.23Tecoras Street Cabinet 2.11Tecoras Street Cabinet Fan 2.16Tecoras Street Cabinet HEC 2.17Tecoras Street Cabinet SC 2.15Temperature Sensor 5.5Thermal Management 3.1Thermal Management Indoor 3.3Thermal Management Outdoor 3.15
W
Wall Case 2.23Wall Mounting Kit Outdoor Wall Case 2.28Water Sensor 5.6