Post on 13-Oct-2020
1
SKETCH:
ATE:
SKETCH NO:
DATE: D09/12/19
TSV-1THIN STONE VENEER
INTERIOR WALLBOARD
VAPOR BARRIER ( IF REQUIRED )
INSULATION
FRAMING AND EXTERIOR SHEATHING
DRIWALL™ AWB OR WB
DRIWALL™ RAINSCREEN
THIN STONE
P.O. Box 241353 Cleveland, OH 44124 P ( 877 ) 514-5336 F ( 440) 605-1120
www.keenebuilding.com
Building Products
CASING BEAD ( OPTIONAL )
DRIWALL™ WEEP SCREED
CONCRETE FOUNDATION!
CODE COMPLIANT LATH
2
SKETCH:
A
T
E:
SKETCH NO:
DATE:D09/12/19
TSV-2THIN STONE VENEER WALL BASE
THIN STONE
CODE COMPLIANT LATH
DRIWALL™ RAINSCREEN
DRIWALL™ AWB OR WB
EXTERIOR SHEATHING
INSULATION
VAPOR BARRIER ( IF REQUIRED )
INTERIOR WALLBOARD
FRAMING
SUB FLOOR
RIM JOIST
FLOOR JOIST
SILL PLATE
KEENEFLASH 100
WRAP SELVAGE EDGE OF DRIWALL™ RAINSCREEN UNDER BOTTOM EDGE AND UP THE BACK SIDE TO CREATE AN INSECT SCREEN
CASING BEAD ( OPTIONAL )
DRIWALL™ WEEP SCREED
CONCRETE FOUNTATION
P.O. Box 241353 Cleveland, OH 44124 P ( 877 ) 514-5336 F ( 440) 605-1120
www.keenebuilding.com
Building Products
3
SKETCH:
A
T
E:
SKETCH NO:
DATE:D09/12/19
P.O. Box 241353 Cleveland, OH 44124 P ( 877 ) 514-5336 F ( 440) 605-1120
www.keenebuilding.com
TSV-3THIN STONE VENEER DRIWALL™ RAINSCREEN LAP
Building Products
THIN STONE
CODE COMPLIANT LATH
DRIWALL™ RAINSCREEN
DRIWALL ™ AWB OR WB
EXTERIOR SHEATHING
INSULATION
VAPOR BARRIER ( IF REQUIRED )
INTERIOR WALLBOARD
LAP SELVAGE EDGE OF BREATHABLE FABRIC OVER THE TOP EDGE OF THE DRIWALL™ RAINSCREEN COURSE BELOW
4
SKETCH:
A
T
E:
SKETCH NO:
DATE:D09/12/19
TSV-4THIN STONE VENEER HOSE BIB PENETRATION
THIN STONE
CODE COMPLIANT LATH
DRIWALL™ RAINSCREEN
DRIWALL ™ AWB OR WB
EXTERIOR SHEATHING
INSULATION
VAPOR BARRIER ( IF REQUIRED )
INTERIOR WALLBOARD
HOSE BIB
KEENE TAPE 100
KEENEFLASH 100
P.O. Box 241353 Cleveland, OH 44124 P ( 877 ) 514-5336 F ( 440) 605-1120
www.keenebuilding.com
Building Products
5
SKETCH:
A
T
E:
SKETCH NO:
DATE:D09/12/19
TSV-5THIN STONE VENEER LIGHT FIXTURE PENETRATION
THIN STONE
CODE COMPLIANT LATH
DRIWALL™ RAINSCREEN
DRIWALL™ AWB OR WB
EXTERIOR SHEATHING
INSULATION
VAPOR BARRIER ( IF REQUIRED )
INTERIOR WALLBOARD
LIGHT FIXTURE
KEENE TAPE 100
KEENEFLASH 100
P.O. Box 241353 Cleveland, OH 44124 P ( 877 ) 514-5336 F ( 440) 605-1120
www.keenebuilding.com
Building Products
6
SKETCH:
A
T
E:
SKETCH NO:
DATE:D09/12/19
TSV-6THIN STONE VENEER ELECTRIC BOX PENETRATION
THIN STONE
CODE COMPLIANT LATH
DRIWALL™ RAINSCREEN
DRIWALL™ AWB OR WB
EXTERIOR SHEATHING
KEENE TAPE 100
KEENEFLASH 100
P.O. Box 241353 Cleveland, OH 44124 P ( 877 ) 514-5336 F ( 440) 605-1120
www.keenebuilding.com
Building Products
INSULATION
VAPOR BARRIER(IF REQUIRED)
INTERIOR WALLBOARD
ELECTRICAL OUTLET
7
SKETCH:
A
T
E:
SKETCH NO:
DATE:D09/12/19
P.O. Box 241353 Cleveland, OH 44124 P ( 877 ) 514-5336 F ( 440) 605-1120
www.keenebuilding.com
TSV-7THIN STONE VENEER VENT PENETRATION
Building Products
THIN STONE
CODE COMPLIANT LATH
DRIWALL™ RAINSCREEN
DRIWALL™ AWB OR WB
EXTERIOR SHEATHING
INSULATION
VAPOR BARRIER ( IF REQUIRED )
INTERIOR WALLBOARD
VENT
KEENE TAPE 100
KEENEFLASH 100
™
8
SKETCH:
A
T
E:
SKETCH NO:
DATE:D09/12/19
TSV-8THIN STONE VENEER EXTERNAL CORNER
P.O. Box 241353 Cleveland, OH 44124 P ( 877 ) 514-5336 F ( 440) 605-1120
www.keenebuilding.com
Building Products
THIN STONE
CODE COMPLIANT LATH
DRIWALL™ RAINSCREEN
DRIWALL™ AWB OR WB
EXTERIOR SHEATHING
INTERIOR WALLBOARD
VAPOR BARRIER ( IF REQUIRED )
FRAMING
INSULATION
9
SKETCH:
A
T
E:
SKETCH NO:
DATE: 09/12/19
TSV-9THIN STONE VENEER INTERNAL CORNER
P.O. Box 241353 Cleveland, OH 44124 P ( 877 ) 514-5336 F ( 440) 605-1120
www.keenebuilding.com
Building Products
THIN STONE
CODE COMPLIANT LATH
DRIWALL™
RAINSCREEN
DRIWALL™ AWB OR WB
EXTERIOR SHEATHING
INTERIOR WALLBOARD
VAPOR BARRIER ( IF REQUIRED )
FRAMING
INSULATION
10
SKETCH:
A
T
E:
SKETCH NO:
DATE: 09/12/19
TSV-10THIN STONE VENEER WINDOW SILL 1
P.O. Box 241353 Cleveland, OH 44124 P ( 877 ) 514-5336 F ( 440) 605-1120
www.keenebuilding.com
Building Products
WINDOW UNIT
SELF-ADHERING FLASHING 100
BACKER ROD & SEALANT
KEENEFLASH 100
CASING BEAD ( OPTIONAL )
INTERIOR WALLBOARD
VAPOR BARRIER ( IF REQUIRED )
INSULATION
EXTERIOR SHEATHING
DRIWALLTM AWB OR WB
DRIWALLTM RAINSCREEN
CODE COMPLIANT LATH
THIN STONE
11
SKETCH:
A
T
E:
SKETCH NO:
DATE: 09/12/19
TSV-11THIN STONE VENEER FLANGED WINDOW SILL
P.O. Box 241353 Cleveland, OH 44124 P ( 877 ) 514-5336 F ( 440) 605-1120
www.keenebuilding.com
Building Products
SELF-ADHERING FLASHING 100
WINDOW FLANGE
BACKER ROD & SEALANT
KEENEFLASH 100
CASING BEAD ( OPTIONAL )
INTERIOR WALLBOARD
VAPOR BARRIER ( IF REQUIRED )
INSULATION
EXTERIOR SHEATHING
DRIWALLTM AWB OR WB
DRIWALL™ RAINSCREEN
CODE COMPLIANT LATH
THIN STONE
FLANGED WINDOW UNIT
12
WINDOW UNIT
SELF-ADHERING FLASHING 100
KEENEFLASH 100
BACKER ROD & SEALANT
CASING BEAD ( OPTIONAL )
DRIWALLTM AWB OR WB
DRIWALL™ RAINSCREEN
THIN STONE
INTERIOR WALLBOARD
VAPOR BARRIER ( IF REQUIRED )
INSULATION
EXTERIOR SHEATHING
FRAMING
CODE COMPLIANT LATH
SKETCH:
A
T
E:
SKETCH NO:
DATE:D09/12/19
TSV-12
P.O. Box 241353 Cleveland, OH 44124 P ( 877 ) 514-5336 F ( 440) 605-1120
www.keenebuilding.com
Building ProductsTHIN STONE VENEER UNFLANGED WINDOW JAMB
13
SKETCH:
A
T
E:
SKETCH NO:
DATE:D09/12/19
TSV-13
P.O. Box 241353 Cleveland, OH 44124 P ( 877 ) 514-5336 F ( 440) 605-1120
www.keenebuilding.com
Building ProductsTHIN STONE VENEER FLANGED WINDOW JAMB
WINDOW UNIT
WINDOW FLANGE
KEENEFLASH 100
BACKER ROD & SEALANT
CASING BEAD ( OPTIONAL )
DRIWALLTM AWB OR WB
DRIWALL™ RAINSCREEN
THIN STONE
INTERIOR WALLBOARD
VAPOR BARRIER ( IF REQUIRED )
INSULATION
EXTERIOR SHEATHING
FRAMING
CODE COMPLIANT LATH
14
SKETCH:
A
T
E:
SKETCH NO:
DATE:D09/12/19
TSV-14THIN STONE VENEER UNFLANGED WINDOW HEAD
P.O. Box 241353 Cleveland, OH 44124 P ( 877 ) 514-5336 F ( 440) 605-1120
www.keenebuilding.com
Building Products
THIN STONE
CODE COMPLIANT LATH
DRIWALL™ RAINSCREEN
DRIWALLTM AWB OR WB
EXTERIOR SHEATHING
INSULATION
VAPOR BARRIER ( IF REQUIRED )
INTERIOR WALLBOARD
FRAMING
KEENEFLASH 100
CASING BEAD ( OPTIONAL )
GAP FOR VENTING & DRAINAGE
WINDOW HEAD FLASHING
SELF-ADHERING FLASHING 100
WINDOW UNIT
15
SKETCH:
A
T
E:
SKETCH NO:
DATE:D09/12/19
TSV-15THIN STONE VENEER FLANGED WINDOW HEAD
P.O. Box 241353 Cleveland, OH 44124 P ( 877 ) 514-5336 F ( 440) 605-1120
www.keenebuilding.com
Building Products
THIN STONE
CODE COMPLIANT LATH
DRIWALL™ RAINSCREEN
DRIWALLTM AWB OR WB
EXTERIOR SHEATHING
INSULATION
VAPOR BARRIER ( IF REQUIRED )
INTERIOR WALLBOARD
FRAMING
SELF-ADHERING FLASHING 100
WINDOW FLANGE CASING
BEAD ( OPTIONAL )
GAP FOR VENTING & DRAINAGE
WINDOW HEAD FLASHING
FLANGED WINDOW UNIT
16
SKETCH:
A
T
E:
SKETCH NO:
DATE: 09/12/19
TSV-16THIN STONE VENEER TOP OF WALL
P.O. Box 241353 Cleveland, OH 44124 P ( 877 ) 514-5336 F ( 440) 605-1120
www.keenebuilding.com
Building Products
ROOF SHINGLES
ROOF EDGE FLASHING
ROOF SHEATHING
TRIM BOARDS
RAFTER
GAP FOR VENTING
CASING BEAD ( OPTIONAL )
FRAMING
INTERIOR WALLBOARD
VAPOR BARRIER ( IF REQUIRED )
INSULATION
EXTERIOR SHEATHING
DRIWALLTM AWB OR WB
DRIWALL™ RAINSCREEN
CODE COMPLIANT LATH
THIN STONE