Post on 24-Jul-2015
Neonatal TransportCE CERTIFIED
WINNER Of
TransNANOTransport Incubators Winner of Emergency Medical Service
TransNANO I
TransNANO II
TransNANO Incubator
No POWER to run
Weights only 7-15 Kgs
Light Weight Construction
made of plastic fibre
Even a nurse can lift with one
handMaintains
constant temp for 3 hours
Fits even in a TATA NANO
Lower Consumption of Supplemental
Oxygen
Dimensions: 26" x 14" x 14"
TransNano – I – Zero Power
Heat the resusable pouch in hot water till
all the solid material turns
into liquid in 10 min.
Place the pouch in baby tray
compartment and lay the baby inside the incubator
Temperature will remain constant
at 36-37 deg C for atleast 3-4 hours
until liquid material doesn’t
solidify again
TransNano – II – 100W Power
Compact size and fast air circulation allows the requirement of just 100W Power and 29°C - 36°C temperature rise is achieved in 5 min
Microprocessor Based PID Temperature Control Mechanism
Backup of more than 2 hours on Car Battery - 12V, 28Ah
FEATURESTraditional Transport Incubators
TransNANO II TransNANO I
POWER Consumes High Powerfrom 200-450W
Consumes only 100W of Power
Consumes ZERO Power
BATTERYTo run for 2 hours, at least 12V, 65Ah Battery needed
Runs on Car Battery onBattery Charger Socket
Not Needed
Runs on Special Mattress
CHARGING
Require frequent chargingas batteries drain out faster
Car Fuel continuouslycharges Car Battery
Mattress has to be heatedfor 5 minutes to melt thesolid material
Temperature Maintenance
Servo Control Mechanism
PID based Servo TempControl with fast AirCirculation
solid material onceliquified maintains temp of mattress at 37°C
RUN TIMERuns for 1-2 hoursdepending on battery
Runs till the time Petrol /Diesel is present in Car
Maintains 37°Ctemperature for 3-4 hours
Traditional Transport Incubators
TransNANO II TransNANO I
TROLLEY
Requires Bulky Trolley to fit Battery, Cylinders
No Need for a Trolley,Can be lifted with one hand
No need for a Trolley, Can be lifted with one hand
WEIGHT At least 30-40 Kg Only 13 Kg Only 7 Kg
AMBULANCE
Baby can be transported only in special NeonatalAmbulances
It can fit in smallest of car or ambulance (adult / neonatal)
It can fit in smallest of car or ambulance (adult / neonatal)
OXYGEN
High Consumption of Oxygen
Low requirement forsupplemental oxygen
Low requirement forsupplemental oxygen
Neonatal Transport• Light weight, ergonomic construction
with ABS moulded cabinet.• PID Based Microprocessor based
Temperature Control• Inbuilt Invertor for operating on DC
Battery• Use AC Power and DC Power
alternatively, DC 12V Car Battery Power on the ambulance.
• Removable Baby Tray with easy positioning device along with cushioned bed.
• Fully accessible, transparent acrylic canopy with guarded ventilation and inlets for Oxygen, IV and sensor cables.
• Natural air flow humidity variance system.
• Audio and Visual Alarms for all functions including overheat, set temperature, sensor failure, power failure.
TPBI 1000Transport Incubators
TPBI 1000 with AUTO LOADING Collapsible Trolley and TransVent Transport Ventilatorand Patient Monitor
Neonatal Transport Systemwith Trolley
• Collapsible Stainless Steel Trolley is specially constructed for using Transport Incubator and Transport Ventilator inside Neonatal Ambulance.
• Space enough for Two Medium Sized Oxygen Cylinders.• Infusion Pump clamping stand as well as space for Patient monitors too. • Heavy Lockable Castor wheels.
THANK YOU
AVI Healthcare Private Limited
Factory:25, Nanddeep Industrial Estate, Kondivita Lane, Near JB Nagar,Andheri East, Mumbai - 400059
Mobile: +91 9322294345, +91 9820228952
Landline: +91 22 28326240 / +91 22 28320452 / +91 66926066
Email id: sales@avihealthcare.com / chirag@avihealthcare.com