TM640

ALARMS, TRENDS AND DIAGNOSTICS

Alarm system

Trend system

Diagnostics

Summary

Alarms, Trends and Diagnostics

Diagnostics

Various methods for assigning URLs

Linking the HTML control to a text group

Linking the HTML control to a text group

URLs for displaying the SDM

Panel size HTMLView size URL

QVGA 316 x 191 http://127.0.0.1/sdm-qvga/qvga.cgi

VGA 620 x 339 http://127.0.0.1/sdm-vga/vga.cgi

XGA 1004 x 567 http://127.0.0.1/sdm-xga/xga.cgi

Alarm system

Trend system

Diagnostics

Summary

Alarms, Trends and Diagnostics

Trend system

Trend control components

Trend curves

Time axis

Measurement cursor

Axis labels

Value axis

Trend container

Creating the trend control

Trend Wizard

Online trend

Data point values

are displayed over time

value = 204060

Setting the time range and sampling rate

Duration

Displayed time range

In this example:

Duration [s]: 90 => 01:30 min

Sampling rate

Sampling rate – specifies the

intervals at which the value is sampled

and displayed

Setting the recording mode

Single

A specific duration

is recorded

Continuous

Time axis is continuous

Current trend values always displayed

02:60

Trend types

User trend

Values from an array

are read and displayed

trend_array = { 20 , 40 , 60 }

50 ms 100 ms 150 ms

Displaying curves in the trend control

Channels

Specifies how many trend curves

are displayed in the control

Linking trend curves with the logic

Trend data

For each trend curve

assign a data point

and color

Linking trend curves with the logic

Linking trend curves with the logic

Appearance

GridGrid and color settings

ScalesColor settings

Configuring the measurement cursor

Trend data properties

Trend data properties

Trend components

Trend data assignments

Alarm system

Trend system

Diagnostics

Summary

Alarms, Trends and Diagnostics

Alarm system

Alarm configuration

Display

Alarm text

Status messages

Error states

Acknowledgement

Everything at a glance

Clearly organized

Bitmaps

Alarm groups

Message type - Acknowledgment requirements

Messages

Operating statesAcknowledgment not required

Non-critical

Warnings

Error states

Acknowledgment preferred

No action required

Alarms

Critical error states

Acknowledgment required

Action necessary

Linking the alarm group with the logic

Effect of the logic on the alarm system

alarmCoffee [ 0 ] = 1

0 00000

0 1 2 3 4 5

0 00001 1 00000 0 00100

24

Alarm control configuration

Alarm lists

CurrentActive and

inactive unacknowledged

HistoryPossible to set which event

is recorded

ConfigurationAlarms from all groups except

group alarms

Alarms can only be bypassed here

ActiveActive unacknowledged alarms

Display configuration

Display configuration

Alarm map - Current

Alarmtext1

Alarm list

Alarmtext5

0 0 0 0 0 0 0 0

0 0 0 00010

0 1 0 00010

0 1 0 00000

0 1 2 3 4 5 6 7

Alarm map - History

Alarmtext1 T

Alarm history

Alarmtext5 T

0 0 0 0 0 0 0 0

0 0 0 00010

0 1 0 00010

0 1 0 00000

0 1 2 3 4 5 6 7

Alarmtext1 R

Alarm system

Trend system

Diagnostics

Summary

Alarms, Trends and Diagnostics

Summary

ASIV ALARMS, TRENDS AND DIAGNOSTICSTM640

TM600Introduction to Visualization

TM610Working with Integrated Visualization

TM640Alarm, Trends and Diagnostics

TM670Advanced Visual Components