Post on 25-Jan-2021
SCALE 1:20
TIMBER FRAMING
TO NZS 3604
H3.1 TIMBER CAVITY BATTENS
@ 300mm MIN.CTRS
STOLITE RENDER SYSTEM
8mm LEVELITE BASECOAT
RENDER
STOARMAT MESHED REINFORCED
RENDER, STOPLEX W SEALER
STOLIT K or MP COLOURED
FINISHING RENDER
6mm FC SHEET INSTALL AS PER
MANUFACTURERS INSTRUCTION
STO uPVC CLIPON FOOT TRAY
REMOVE BACK TAB IF
REQUIRED
uPVC VERMIN TRAY WITH 15mm
MIN. DRIP EDGE
WALL UNDERLAY MEETING
REQUIREMENTS E2/AS1
CONCRETE FOUNDATION AS PER NZS3604 OR
SPECIFIC ENGINEERING REQUIREMENTS
MESH SHEET JOINT
FIXINGS:
200mm on STUDS
150mm on TOP & BOTTOM PLATES
300mm on DWANGS
SHEETS FIXED VERTICALLY
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered
Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to
alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure
they have and use the current Sto details and specifications on site.
STOLITE
SYSTEM
STOLITE CONSTRUCTION SYSTEM
CAVITY BATTEN SETOUT (600ctrs) - ISOMETRIC
SL 100
2017
SCALE 1:20
TIMBER FRAMING
TO NZS 3604
H3.1 TIMBER CAVITY BATTENS
@ 400mm MIN.CTRS
STOLITE RENDER SYSTEM
STO uPVC CLIPON FOOT TRAY
REMOVE BACK TAB IF
REQUIRED
uPVC VERMIN TRAY WITH 15mm
MIN. DRIP EDGE
WALL UNDERLAY MEETING
REQUIREMENTS E2/AS1
CONCRETE FOUNDATION AS PER NZS3604 OR
SPECIFIC ENGINEERING REQUIREMENTS
8mm LEVELITE BASECOAT
RENDER
STOARMAT MESHED REINFORCED
RENDER, STOPLEX W SEALER
STOLIT K or MP COLOURED
FINISHING RENDER
6mm FC SHEET INSTALL AS PER
MANUFACTURERS INSTRUCTION
MESH SHEET JOINT
FIXINGS:
200mm on STUDS
200mm on TOP & BOTTOM PLATES
SHEETS FIXED VERTICALLY
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered
Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to
alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure
they have and use the current Sto details and specifications on site.
STOLITE
SYSTEM
STOLITE CONSTRUCTION SYSTEM
CAVITY BATTEN SETOUT (400 ctrs) - ISOMETRIC
SL 101
2017
SCALE 1:20
STEEL FRAMING
AS SPECIFIED
H3.1 TIMBER CAVITY BATTENS
@ 300mm MIN.CTRS
STOLITE RENDER SYSTEM
8mm LEVELITE BASECOAT
RENDER
STOARMAT MESHED REINFORCED
RENDER
STOLIT K or MP COLOURED
FINISHING RENDER
6mm FC SHEET INSTALL AS PER
MANUFACTURERS INSTRUCTION
STO uPVC CLIPON FOOT TRAY
REMOVE BACK TAB IF
REQUIRED
uPVC VERMIN TRAY WITH 15mm
MIN. DRIP EDGE
WALL UNDERLAY MEETING
REQUIREMENTS E2/AS1
CONCRETE FOUNDATION AS PER NZS3604 OR
SPECIFIC ENGINEERING REQUIREMENTS
THERMAL BREAK STRIPS WITH A
MIN. R VALUE of 0.3 TO ALL
STEEL FRAMING
MESH SHEET JOINT
FIXINGS:
AS PER SHEET MANUFACTURER
INSTRUCTION
SHEETS FIXED VERTICALLY
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered
Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to
alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure
they have and use the current Sto details and specifications on site.
STOLITE
SYSTEM
STOLITE CONSTRUCTION SYSTEM
CAVITY BATTEN SETOUT STEEL FRAME/THERMAL BREAK (600ctrs)
SL 102
2017
N.T.S
300
600
5.4M MAX.
DOORWINDOW
VERTICAL CONTROL JOINTS
AT 5.4M CTRS ON DOUBLE
STUDS
SHEET JOINTS 200mm
PAST OPENINGS
H3.1 TIMBER BATTENS FIXED
OVER FRAME & BUILDING
UNDERLAY
H3.1 HORIZONTAL SPACERS x
100mm LONG, FIX WITH ONE NAIL
CENTERED. HORIZONTAL SPACERS
MUST BE SET TO A FALL 5° MIN.
NOTE:
IF STUDS ARE PLACED AT 400 mm CTRS NO INTERMEDIATE
BATTENS ARE REQUIRED. 100mm LONG SPACERS WILL BE
REQUIRED ON BOTTOM PLATE & FIXINGS ARE ALL AT
200mm CTRS
2nd LEVEL
INTERMEDIATE CAVITY BATTENS
REQUIRED ON 600mm FRAMING
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered
Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to
alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure
they have and use the current Sto details and specifications on site.
STOLITE
SYSTEM
STOLITE CONSTRUCTION SYSTEM
CAVITY BATTEN LAYOUT (300 & 600 ctrs) ELEVATION
SL 103
2017
SL-100-Cavity batten setout 600crs isometricSheets and ViewsCavity batten setout 600crs isometric
SL-101-Cavity batten setout 400 crs isometricSheets and ViewsCavity batten setout 400 crs isometric
SL-102-Cavity batten setout steel frameSheets and ViewsCavity batten setout steel frame
SL-103-Cavity batten layout elevationSheets and ViewsCavity batten layout elevation