Thermal Dynamics Series - Fluid Power Dynamics Cooler Core Fan DC.pdf · Thermal Dynamics...

Post on 25-Aug-2020

7 views 0 download

Transcript of Thermal Dynamics Series - Fluid Power Dynamics Cooler Core Fan DC.pdf · Thermal Dynamics...

Thermal Dynamics International, Inc. Sales & Customer Service: 800.358.4396 • www.thermaldynamics.com

DIMENSIONS

SPECIFICATIONS

PERFORMANCE

APPEARANCE

25

DB-00341DC

Flow Range (GPM): .........5 - 30Heat Rejection Range (BTU/Hr): 22,700 - 33,000Fitting Size: .......................1” FPTMaterial Copper Tube: ....................CDA122Inner Tube: .......................Al-3003Inner Fin: ..........................Al - 1100Outer Fin: .........................Al - 1100Fitting: ...............................CopperCooler Weight (lbs.)Total Weight : ....................22 lbs.

Thermal Dynamics International, Inc. Sales & Customer Service: 800.358.4396 • www.thermaldynamics.com

DIMENSIONS

SPECIFICATIONS

PERFORMANCE

APPEARANCE

26

Flow Range (GPM): .........4 - 20Heat Rejection Range (BTU/Hr): 15,100 - 19,700Fitting Size: .......................3/4” FPTMaterial Copper Tube: ....................CDA122Inner Tube: .......................Al-3003Inner Fin: ..........................Al - 1100Outer Fin: .........................Al - 1100Fitting: ...............................CopperCooler Weight (lbs.)Total Weight : ....................20 lbs.

DB-00343DC

Thermal Dynamics International, Inc. Sales & Customer Service: 800.358.4396 • www.thermaldynamics.com

DIMENSIONS

SPECIFICATIONS

PERFORMANCE

APPEARANCE

27

Flow Range (GPM): .........5 - 21Heat Rejection Range (BTU/Hr): 22,900 - 31,100Fitting Size: .......................3/4” FPTMaterial Copper Tube: ....................CDA122Inner Tube: .......................Al-3003Inner Fin: ..........................Al - 1100Outer Fin: .........................Al - 1100Fitting: ...............................CopperCooler Weight (lbs.)Total Weight : ....................24 lbs.

DB-00345DC

Thermal Dynamics International, Inc. Sales & Customer Service: 800.358.4396 • www.thermaldynamics.com

DIMENSIONS

SPECIFICATIONS

PERFORMANCE

APPEARANCE

28

Flow Range (GPM): .........10 - 30Heat Rejection Range (BTU/Hr): 41,900 - 52,900Fitting Size: .......................1” FPTMaterial Copper Tube: ....................CDA122Inner Tube: .......................Al-3003Inner Fin: ..........................Al - 1100Outer Fin: .........................Al - 1100Fitting: ...............................CopperCooler Weight (lbs.)Total Weight : ....................30 lbs.

DB-01322DC

Thermal Dynamics International, Inc. Sales & Customer Service: 800.358.4396 • www.thermaldynamics.com

Dimensions

specifications

performance

appearance

33

Flow Range (GPM): .........10 - 30Heat Rejection Range (BTU/Hr): 57,300 - 72,300Fitting Size: .......................1” FPTMaterial Copper Tube: ....................CDA122Inner Tube: .......................Al-3003Inner Fin: ..........................Al - 1100Outer Fin:..........................Al - 1100Fitting: ...............................CopperCooler Weight (lbs.)Total Weight : ....................51 lbs.

DB-02162DC

Thermal Dynamics International, Inc. Sales & Customer Service: 800.358.4396 • www.thermaldynamics.com

DIMENSIONS

SPECIFICATIONS

PERFORMANCE

APPEARANCE

34

DB-2138DC

Flow Range (GPM): ......... 1 - 6Heat Rejection Range (BTU/Hr): 12,800 - 18,000Fitting Size: .......................3/8” FPTMaterial Copper Tube: ....................CDA122Inner Tube: .......................Al-3003Inner Fin: ..........................Al - 1100Outer Fin: .........................Al - 1100Fitting: ...............................AluminumCooler Weight (lbs.)Total Weight : .................... N/A

Thermal Dynamics International, Inc. Sales & Customer Service: 800.358.4396 • www.thermaldynamics.com

Dimensions

specifications

performance

appearance

34

Flow Range (GPM): ......... 8 - 40Heat Rejection Range (BTU/Hr): 36,000 - 41,000Fitting Size: .......................SAE #20Material Aluminum Tube:................Al-3003Inner Fin: ..........................Al - 1100Outer Fin:..........................Al - 1100Fitting: ...............................AluminumCooler Weight (lbs.)Total Weight : .................... N/A

DB-5458DC02

Thermal Dynamics International, Inc. Sales & Customer Service: 800.358.4396 • www.thermaldynamics.com

Dimensions

specifications

performance

appearance

37

DB-6226-SF12

Flow Range (GPM): ......... 10 - 40Heat Rejection Range (BTU/Hr): 78,000 - 94,000Fitting Size: .......................#16 SAE ORBMaterial Extruded Aluminum Oval TubeInner Fin: ..........................Al - 1100Outer Fin:..........................Al - 1100Fitting: ...............................AluminumCooler Weight (lbs.)Total Weight (dry) : ........... 60 lbs.

Hea

t Dut

y (B

TU/ H

R)

Pres

sure

Dro

p (P

SI)

Thermal Dynamics International, Inc. Sales & Customer Service: 800.358.4396 • www.thermaldynamics.com

Dimensions

specifications

performance

appearance

36

TDI-14344DC-12

Flow Range (GPM): ......... 10 - 40Heat Rejection Range (BTU/Hr): 23,000 - 25,000Fitting Size: .......................#16 SAE ORBMaterial Aluminum Bar/PlateInner Fin: ..........................Al - 1100Outer Fin:..........................Al - 1100Fitting: ...............................AluminumCooler Weight (lbs.)Total Weight (dry) : ........... 13 lbs.

Hea

t Onl

y (B

TU /

HR

)

Pres

sure

Dro

p (P