Temp measurement

Post on 06-May-2015

6.187 views 0 download

Transcript of Temp measurement

Powerpoint Templates Page 1

Characterization & Optimization of Temperature

Sensor Using LABVIEW

Completed By :

Shabnam Niknezhad

Samreen Shaikh

Guide :

Prof. SAJID NAEEM

MSc Electronic ScienceDepartment of Electronic SciencePoona College of Arts , Science & Commerce

Powerpoint Templates Page 2

AIM & OBJECTIVESAim : • To study of LabVIEW and its application.

Objectives :• Characterization and Optimization of temperature sensors.• To interface DAQ card with LabVIEW.• To design ON/OFF controller to control Heater.• To develop basic programming architectures.• To develop Lab VIEW software for data acquisition, display

and/or control purpose.• To create application that use plug in DAQ device• To develop necessary interface hard ware so as to accumulate

variety of test and measurement procedure.• To study different transducers under the control of virtual lab.

Powerpoint Templates Page 3

INTRODUCTION• The primary objective of process control is to control physical

parameter such as temperature, pressure, flow rate, level, force, light intensity and so on. As these parameter can change either spontaneously or because of external influences, we must constantly provide corrective action to keep these parameters constant or within the specified range.

• To control process parameter, we must know the value of that parameter and hence it is necessary to measure that parameter.

Powerpoint Templates Page 4

• An instrumentation system consists of three major elements :

1. input device2. signal conditioning circuit 3. output device. The input quantity for most instrumentation system is non electrical in order to use electrical methods and techniques for measurement the non electrical quantity is converted into proportional electrical signal by a device

called “transducer”.

Powerpoint Templates Page 5

Transducer• A transducer is a device that converts one form of energy to another. Energy types include electrical, mechanical, electromagnetic (including light), chemical, acoustic or thermal energy. • While the term transducer commonly implies the use of a sensor/detector,

any device which converts energy can be considered a transducer. • Transducers are widely used in measuring instruments.

Bioelectrical TechnologyAt the heart of this system a wireless microelectromechanical system (MEMS) sensor in the contact lens that acts as a transducer, antenna, and mechanical support for read-out electronics.

Powerpoint Templates Page 6

Temperature sensor - overview

• In many systems, temperature control is fundamental. There are a number of passive and active temperature sensors that can be used to measure system temperature, including:

1. thermocouple,2. resistive temperature detector,3. thermistor, 4. silicon temperature sensors.

• These sensors provide temperature feedback to the system controller to make decisions such as, over-temperature shutdown, turn-on/off cooling fan, temperature compensation or general purpose temperature monitor.

Powerpoint Templates Page 7

Common Methods of Interfacing a Sensor

Powerpoint Templates Page 8

Block Diagram

LABVIEW

SIGNAL CONDITIONING

DATA AQUISATION

SYSTEMSENSOR

• Signals are input to a sensor, conditioned, converted into bits that a computer can read, and analyzed to extract meaningful information.

Powerpoint Templates Page 9

Study of LabVIEW

Powerpoint Templates Page 10

Lab VIEW (Laboratory Virtual Instrument Engineering Workbench.)

• Lab VIEW is a graphical programming language that uses icons instead of lines of text to create programs.

• Lab VIEW is a platform and development environment for a visual programming language from National Instruments.

Powerpoint Templates Page 11

virtual instruments

• Lab VIEW programs are called virtual instruments, or VIs, because their appearance and operation imitate physical instruments, such as oscilloscopes and multimeters.

• After build the user interface, add code using VIs and structures to control the front panel objects. The block diagram contains this code.

Powerpoint Templates Page 12

LABVIEW INTRODUCTION

Two “sets” for development Front Panel Block Diagram

Wiring connections

LabVIEW Conventions

Running LabVIEW programs

Powerpoint Templates Page 13

LABVIEW Front Panel

• It is the user interface for the VI. • Used to display Controls or Indicators.• It contains the Controls palette.• Highly customizable.

Powerpoint Templates Page 14

LABVIEW Block DiagramThe block diagram provides the area for the graphical code

• Actual program.• Invisible to user.• Read left to right, like a book.

TheFunctions Palette

Powerpoint Templates Page 15

LabVIEW Palettes

1- The Front panel contains:

The Controls Palette

2- The Block Diagram panel contains:

The Functions Palette

Powerpoint Templates Page 16

1- Controls Palette • To open the control palette from the front

panel :

• Or click the mouse right button.

Powerpoint Templates Page 17

• The Controls palette contains the controls and indicators that used to create the front panel.

ControlsIndicators

Powerpoint Templates Page 18

Some Controls & Indicators

Powerpoint Templates Page 19

2- Functions Palette • To open the Functions palette from the block

diagram window :

• Or click the mouse right button.

Powerpoint Templates Page 20

Some Functions

Powerpoint Templates Page 21

Terminals :

When you place a control

(or indicator) on the

FRONT PANEL

LabVIEW automatically creates a correspondingcontrol (or indicator) terminal on the

BLOCK DIAGRAM

Powerpoint Templates Page 22

Basic wires used in block diagramsand corresponding types:

• Each wire has different style or color, depending on the data type that flows through the wire:

Powerpoint Templates Page 23

LabVIEW Conventions

• Front panel items Controls and indicators

• Block diagram items Program structures (loops, case structures, math, etc.)

• Controls vs. Indicators Wires attach to controls on the right (give values) Wires attach to indicators on the left (receive values)

• Wiring colors Wires are color coded to correspond to data types

Powerpoint Templates Page 24

Controls and Functions Palettes

Graphical, floating palettesused to place controls and indicators on the front panel, or to build the block diagram.

Controls Palette (Front Panel)

Functions Palette (Block Diagram)

Powerpoint Templates Page 25

Creating a front panel

• Right click to select the controls palette

• Drag and drop the components

• As you place components a corresponding terminal will appear in the diagram window

Powerpoint Templates Page 26

Wiring the diagram

• Right click to select the functions palette

• Drag and drop functions

• Select the wiring tool

• Drag the wire between terminals

Powerpoint Templates Page 27

Powerpoint Templates Page 28

Basic Examples :• LabVIEW is written on graphical structure.

• While in LabVIEW summation is a function and it is represent by following symbol.

• In LabVIEW, such mathematical and logical functions are represented graphically.

Powerpoint Templates Page 29

Add and multiply two given numbers and display the results

Powerpoint Templates Page 30

Converting ºC to ºF

°F = (1.8 * °C) + 32

Control

Indicator

Powerpoint Templates Page 31

Introduction of DAQ card

Powerpoint Templates Page 32

What is DAQ System

• DAQ systems capture, measure, and analyze physical phenomena from the real world.

• Light, temperature and pressure are examples of the different types of signals that a DAQ system can measure.

• Data acquisition is the process of collecting and measuring electrical signals and sending them to a computer for processing.

• Electrical signals comes from Transducers.

Powerpoint Templates Page 33

The building blocks of a DAQ system includes:

1. Transducer: A device that converts a physical phenomenon such as light, temperature, pressure, or sound into a measurable electrical signal such as voltage or current.

2. Signal: The output of the transducer.3. Signal conditioning: Hardware that you can connect to the

DAQ device to make the signal suitable for measurement or to improve accuracy or reduce noise.

4. DAQ hardware: Hardware you use to acquire, measure, and analyze data.

5. Software: NI application software is designed to help you easily design and program your measurement and control application (LABVIEW).

Powerpoint Templates Page 34

Why Signal Conditioning To measure signals from transducers, you must convert them

into a form a measurement device can accept.• Common types of signal conditioning include amplification,

linearization, transducer excitation, and isolation.

Powerpoint Templates Page 35

What type of device to use

The trade-off usually falls between :

• 1- Resolution (bits) & Code Width

• 2- Sampling rate (samples/second)

• 3- Number of channels, and data transfer rate (usually limited by “bus” type: USB, PCI, PXI, etc.).

Powerpoint Templates Page 36

Types of Data Acquisition and Control Devices

Powerpoint Templates Page 37

DAQ Device Properties

DAQ devices have four standard elements:

1. Analog input (AI)2. Analog output (AO)3. Digital I/O (DIO)4. Counter/Timers

Powerpoint Templates Page 38

USB DAQ :• USB -6008 & USB -6009 Low – Cost USB DAQ.The National Instruments USB-6009 provides basic data acqusition functionality for applications such as simple data logging, portable measurements , and academic lab experiments.The NI USB _6008 and NI USB 6009 are ideal for students.

Create measurement application by programing the NI USB-6009 using LabVIEW and NI_DAQmx driver software for Windows.

Powerpoint Templates Page 39

Feature of DAQ 6009

• Eight 14-bit analog inputs.• 12 digital I/O lines.• 2 analog outputs. • 1 counter.

Analog Digital

1

32

17

16

Powerpoint Templates Page 40

DAQ6009 Details

Overlay Label with Pin Orientation Guide

Comb icon Jack

Screw Terminal Blocks

Signal Labels

Powerpoint Templates Page 41

NI USB-6009 Pins

Powerpoint Templates Page 42

How to Select DAQ Device & Accessories

• Open the Labview program, in the Block Diagram select functions, express input then select the DAQ Assistant icon.

Powerpoint Templates Page 43

How to Select DAQ Device(Input & Output Channels)

• Select “Analog Input” so as to input your analog data to the computer and Labview.

Powerpoint Templates Page 44

How to Select DAQ Device(Input & Output Channels)

• We have 16 physical input channels from ai0 to ai15, select a channel like ai0.

Powerpoint Templates Page 45

How to Select DAQ Device(Input & Output Channels)

• Select your input voltage setup

Powerpoint Templates Page 46

How to Select DAQ Device(Input & Output Channels)

• Now make the connections and select test then Run to see the input voltage.

Powerpoint Templates Page 47

How to Select DAQ Device(Input & Output Channels)

• Example

Powerpoint Templates Page 48

Introduction of Sensors

Powerpoint Templates Page 49

LM35

• The LM35 is an integrated circuit sensor that can be used to measure temperature with an electrical output proportional to the temperature (in oC).

Powerpoint Templates Page 50

What Can Expect When Use An LM35?

• The output voltage is converted to temperature by a simple conversion factor.

• The sensor has a sensitivity of 10mV / oC.• Use a conversion factor that is the reciprocal, that is 100 oC/V.• The general equation used to convert output voltage to

temperature is:

Temperature ( oC) = Vout * (100 oC/V)

– So if Vout is 1V , then, Temperature = 100 oC

• The output voltage varies linearly with temperature.

Powerpoint Templates Page 51

Why Use LM35s To Measure Temperature?

• Measure temperature more accurately than a using a thermistor.

• The sensor circuitry is sealed and not subject to oxidation, etc.

• The LM35 generates a higher output voltage than thermocouples and may not require that the output voltage be amplified.

Powerpoint Templates Page 52

How does LM35 work?

• It has an output voltage that is proportional to the Celsius temperature.

• The scale factor is 10mV/oC .• The LM35 does not require any external

calibration or trimming and maintains an accuracy of +/-0.4 oC at room temperature and +/- 0.8 oC over a range of 0 oC to +100oC.• Vc = 4 to 30v• 5v or 12 v are typical values used.

Powerpoint Templates Page 53

Photo of the LM 35 wired on a circuit board.

– The white wire in the photo goes to the power supply.

– Both the resistor and the black wire go to ground.

– The output voltage is measured from the middle pin into ground .

Power supply

Output voltage Ground

Powerpoint Templates Page 54

Real Picture

LM35

Powerpoint Templates Page 55

Result in Block Diagram

Temperature ( oC) = Vout * (100 oC/V)

Convert from Dynamic Data

Powerpoint Templates Page 56

Result in Front Panel (heating)

XY Graph

Powerpoint Templates Page 57

Result in Front Panel (cooling)

XY Graph

Powerpoint Templates Page 58

Thermistor

• Thermistors are built with semiconductor materials and can have either a positive (PTC) or negative (NTC) temperature coefficient. However, the NTC is typically used for temperature sensing.

NTC

Powerpoint Templates Page 59

• Advantages of thermistors include a very high sensitivity to changes in temperature (having a thermal response of up to -100Ω/°C at 25°C),fast response time and low cost.

• The main drawback of thermistors is that the change in resistance with temperature is highly non-linear at temperatures below 0°C and greater than 70°C.

Powerpoint Templates Page 60

Electrical Connections of Thermistor

• A simple voltage divider is created with a reference resistor (R1) and the thermistor (RT).

• A constant voltage source is supplied (VREF) with the output of the voltage divider (Vout)directly correlating to temperature.

Powerpoint Templates Page 61

• The response is shown in the graph of temperature vs. output voltage to the right

• of the circuit. It is fairly linear in the range of 0-70°C.

LINEAR

Powerpoint Templates Page 62

Why Use Thermistors To Measure Temperature?

• They are inexpensive, rugged and reliable.• They respond quickly.

Powerpoint Templates Page 63

Thermistor – Block diagram(Heating & Cooling)

Convert temp(F) to (C)

T= ((1/298) +(1/4038)*ln(v/(5-v)))**(-1)*1.8-460 of

Powerpoint Templates Page 64

Thermistor-Front panel(Heating)

Powerpoint Templates Page 65

Thermistor –Front panel(Cooling)

Powerpoint Templates Page 66

Real Picture

Thermistor

Powerpoint Templates Page 67

AD590 Circuit

Powerpoint Templates Page 68

Solid State Temperature Sensor(Linear 1 Microamp per Kelvin Output)

• Solid state' temperature sensor has an easy to use linear voltage output, unlike conventional resistive sensors.

• The AD590 is a small temperature transducer that converts a temperature input into a proportional current output.

• The advanced technology in the AD590 is especially suited for special temperature measurement and control applications between -55 and 150°C (-67 to 302°F) when solid state reliability, linearity and accuracy are required.

• The size and responsiveness of the AD590 make it perfect for uses where size is a consideration, such as on PC boards or heat sinks.

Powerpoint Templates Page 69

Specifications

• Absolute Maximum Ratings• Forward Voltage (E+ to E-): +44V• Reverse Voltage (E+ to E-): -20V• Breakdown Voltage• (case to E+ or E-): ±200V• Lead Temperature: 300°C• Voltage Range: 4 to 30 Vdc• Nominal Current Output at 25°C• (298.2 K): 298.2 μA• Nominal Temperature Coefficient:

1 μA/K

• Calibration Error: J: ±5.0°C maximum (K: ±2.5°C)• Absolute Error: Without external• Calibration Adjustment: J: ±10.0°C max (K: ±5.5°C); W/25°C error set to zero J: ±3.0°C max (K: ±2.0°C)• Repeatability: ±0.1°C max• Long-Term Drift: ±0.1°C/month max

Powerpoint Templates Page 70

AD590

• The AD590 solid-state temperature sensor produces an output of 100mV per degree Celsius :

Temperature = Voltage * 100• For example we have 0.35(v) in 35(degree

Celsius).

Powerpoint Templates Page 71

AD590 –block diagram(Heating & Cooling)

Temperature = Voltage * 100

Powerpoint Templates Page 72

AD590- Front Panel(Heating)

Powerpoint Templates Page 73

AD590- Front Panel(Cooling)

Powerpoint Templates Page 74

Response temperature vs voltage

(Heating)

Powerpoint Templates Page 75

Response temperature vs voltage

(Cooling)

Powerpoint Templates Page 76

Real Picture

AD590

Powerpoint Templates Page 77

PT100

• The principle of operation is to measure the resistance of a platinum element. The most common type (PT100) has a resistance of 100 Ω at 0 °C and 138.4 ohms at 100 °C. There are also PT1000 sensors that have a resistance of 1000 ohms at 0 °C.

• The relationship between temperature and resistance is approximately linear over a small temperature range: for example, if you assume that it is linear over the 0 to 100 °C range, the error at 50 °C is 0.4 °C.

Powerpoint Templates Page 78

Circuit Diagram of PT100

Powerpoint Templates Page 79

Features

1. Extremely accurate.2. Fairly good linearity.3. Variety of packages.4. Wire wound or thin film.

Powerpoint Templates Page 80

Applications

1. Industrial instrumentation.2. Hot wire anemometers.3. Laboratory quality measurements.4. Air , gas and liquid monitoring.5. Petrochemical.

Powerpoint Templates Page 81

Real picture

PT100

Powerpoint Templates Page 82

PT100-Block Diagram(Heating)

R=100(1+(t*0.00385))

Powerpoint Templates Page 83

PT100-Block Diagram(Cooling)

R=100(1+(t*0.00385))

Powerpoint Templates Page 84

PT100-Front Panel(Heating)

Powerpoint Templates Page 85

PT100-Front Panel(Cooling)

Powerpoint Templates Page 86

Response graph of temperature vs. output voltage

(Heating)

Powerpoint Templates Page 87

Response graph of Temperature vs. output Voltage

(Cooling)

Powerpoint Templates Page 88