Post on 27-Jan-2021
System Display and Controller
Contents
Basic Navigation…………………………………………………..…... 2
Menu Maps -MATE System Display and Controller Basic Setup……………. 2MATE System Display and Controller Advanced Setup………. 3MATE System Display and Controller AGS Menu………….. 4-5Inverter Setup…………………………………………………….. 6-7Charge Controller Setup………………………………………… 8FLEXnet DC Setup………………………………………………. 9-10
900-0131-01-00 Rev A.vsd\TOC\2012-03-21©2012 OutBack Power Technologies. All Rights Reserved.
WARNING: SHOCK HAZARD
Consult the MATE Owner’s Manual for detailed information on safety and installation procedures.
900-0131-01-00 Rev A.vsd\Menu Map Basics\2012-03-21©2012 OutBack Power Technologies. All Rights Reserved. Page 1
BA
SIC
NA
VIG
ATI
ON
The following pages are intended as a quick reference guide for the menu map of the MATE Series System Display and Controller. This document is for use with the products MATE and MATE2. It cannot be used with the MATE3.
See the MATE Series Owner’s Manual for detailed information about the menu structure, MATE features, and hot/soft key functions. See the inverter, charge controller, and DC monitor manuals for detailed information about specific features and functions that are controlled by the menus.
------------------choose device:
FX MATE
Selection from Main Menu
Device Selection Menu
SETUP/FX----------------choose categoryDevice Menu Title(s)
SETUP/FX/SEARCH------P016
DOWN INC DEC PORT
Menu Item
SETUP/FX/SEARCH------P01searchsensitivityDOWN INC DEC PORT
Setpoint or function for the Menu Item
SETUP/FX/SEARCH------search 6sensitivityDOWN INC DEC PORT
Port
MAIN--------------------3:02:14P
SUM STATUS SETUP ADV
Main Screen
Main MenuSoft Keys
To cycle through the devices connected to the HUB, press the soft key.
Select this option to proceed
Available menus
Adjusts the set points value
Switches between devices on the ports of the Communications HUB
Soft Key Color Code:
Navigation colors
Selects a function (e.g., ON, OFF, AUTO)
Soft key functions will vary depending on the selected menu and are defined by the word above the key in the LCD.
MAIN-------------------3:02:14P
SUM STATUS SETUP ADV
To return to the Main screen at any time:
Press and hold the 2 left soft keys at the same time. Release when the Main screen appears.
If accompanied by a dashed line, pressing that soft key will return the user to the location identified by the dashed line. This will vary depending on the devices in the system.
Indicates a 1-screen movement within a Menu. These are color coded according to their function or purpose.
Navigation:
Soft Keys
Soft Keys
LCD Screen
LCD Screen
INV Hot Key
AC IN Hot Key
AC IN Hot Key
INV LED
INV Hot Key
INV LED
AC IN LED
900-0131-01-00 Rev A.vsd\MATE Basic Setup\2012-03-21©2012 OutBack Power Technologies. All Rights Reserved. Page 2
(C)2009OutBack
PowerSystems
VersionCode a.a.aSerial #xxxxxxxxScreen EE b.bb
Searching for Devices
FX Found
Searching for Devices
CC Found
Searching for Devices
DC Found
Port Assignment1> FX 2>CC 3> DC 4>5> 6> 7> 8>9> 10> 2M>
Searching for Devices
HUB Found
SETUP/MATE/PAGE1-------mate code rev: 4.1.3choose category:CLOCK CNT GLOW PG2
Current DayTu 01/01/09
INC SETDAY MONTH
Current MonthTu 01/01/09
INC SETMONTH DATE
Current DateTu 01/01/09
INC SETDATE YEAR
Current YearTu 01/01/09
INC DECYEAR YEAR DONE
Current Minute12:00:00P
INC DEC RESETMIN MIN SEC DONE
Current Hour12:00:00P
INC SETHOUR MIN
SETUP/MATE/CNT-------contrast 30%
BACK INC DEC
SETUP/MATE/GLOW-------backlight controls
BACK LEVEL MODE TIME
SETUP/MATE/GLOW/LEVELbacklight 100%
BACK INC DEC
SETUP/MATE/GLOW/MODEcurrent code: AUTO
BACK OFF AUTO ON
SETUP/MATE/GLOW/TIMEglow Off 5 minstimeBACK INC DEC
SETUP/MATE/CLOCK-------Tu 1/01/09
12:00:00PBACK DATE TIME
SETUP/MATE/SUM-------summary control
BACK TYPE DELAY ROLL
SETUP/MATE/SUM/TYPE----summary screen typeBACK INC DEC
SETUP/MATE/SUM/DELAY-Sum screen 19 minsDelay timeBACK INC DEC
SETUP/MATE/SUM/DELAY-Sum screen 10 secondsRoll rateBACK INC DEC
SETUP/MATE/COMM/PC------PC communications: OFF
BACK OFF ON
SETUP/MATE/COMM--------Comm errors:
BACK VIEW RSET
00:000 01:000 02:00003:000 04:000 05:00006:000 07:000 08:00009:000 10:000 2M:000
After Resetting Comm Errors
SETUP/MATE/PAGE2-------choose category:
PG1 SUMRY COMM PG3
SETUP/MATE/PAGE3-------choose category:
PG2 BEEP MAIN
SETUP/MATE/COMM--------Choose category:
BACK REPOLL PC DEBUG
00:000 01:000 02:00003:000 04:025 05:00106:001 07:001 08:00109:001 10:001 2M:001
Viewing Comm Errors
11
2
3
4
5
6
Setting up the MATE or MATE2 includes:1. Setting the Clock (date and time)2. Setting the screen contrast.3. Setting the Glow time.4. Setting how the Summary screens are
displayed.5. Setting communication options.6. Setting Beep tone functions.
Setpoints:NoneRoll: rotates between devicesFX OnlyCC OnlyDC OnlyDC Simple
1
Main ScreenMAIN----------------
3:02:14P
SUM STATUS SETUP ADV
Setpoints (Current Day):Monday through Sunday
Setpoints (Current Month):01 through 12
Setpoints (Current Date):01 through 31
Setpoints (Current Year):09 through xx
Setpoints (Current Hour):01-12AM or 01-12PM
Setpoints (Reset Sec):Resets seconds to 00
1
2
3
4
5
6
Varies depending on attached devices. Automatically returns
to the Main Screen.
Repolling
SETUP------------------choose device:
FX MATE
MAIN--------------------3:02:14P
SUM STATUS SETUP ADV
Main Screen
Startup ScreensMAIN----------------
3:02:14P
SUM STATUS SETUP ADV
To return to the Main screen at any time:
Press and hold the 2 left soft keys at the same time. Release when the Main screen appears.
Port Assignment1> FX 2>CC 3> DC 4>5> 6> 7> 8>9> 10> 2M>
Searching for Devices
HUB Found
SETUP/MATE/BEEP--------button beep tone ON
BACK OFF ON
MA
TE
AC IN INV
MAIN----------------3:02:14P
SUM STATUS SETUP ADV
G'day Mate
MA
TE
(continued)
900-0131-01-00 Rev A.vsd\MATE ADV Setup\2012-03-21©2012 OutBack Power Technologies. All Rights Reserved. Page 3
Accessing the Advanced Menu:
ADV--------------------choose device
FX CC DC MATE
Changing more detailed operating parameters requires access to the
Advanced Setup Menu.
ADV/MATE/HBX------------hbx-use 24.0 Vdcgrid set pointDOWN ADV INC DEC
ADV/MATE/HBX------------hbx-use 1.0 hrsgrid delayDOWN UP INC DEC
ADV/MATE/HBX------------hbx-drop 26.0 Vdcgrid set pointDOWN UP INC DEC
ADV/MATE/HBX------------hbx-drop 1.0 hrsgrid delayDOWN UP INC DEC
ADV/MATE/HBX------------ac input USEcontrolDOWN UP CHANGE
ADV/MATE/HBXend of hbx menu
UP TOP ADV
ADV/MATE/GRIDUSE--------griduse enable: OFF
DOWN ADV OFF ON
ADV/MATE/GRIDUSEend of griduse menu
UP TOP ADV
ADV/MATE/HBX------------ac input USEcontrolDROP USE HBX DONE
ADV/MATE/PAGE1choose category
HBX GRIDUSE AGS PG2
ADV/MATE/PAGE3------------advanced chargerfloat control
PG2 CC FN-DC PG4
ADV/MATE/PG3/CC-----------enable CC floatcoordination: Yes
PG3 YES NO ADV
ADV/MATE/PG3/FN-DC--------enable FN-DC chargetermination: YesPG3 YES NO ADV
ADV/MATE/PAGE2----------choose category:
PG1 DEFAULTS PG3
ADV/MATE/DEFAULT----------reset MATE to factory defaultRESET NO
Page 1 Page 2 Page 3
Page 4
MAIN--------------------3:02:14P
SUM STATUS SETUP ADV
Charge Controller and FLEXnet DC Menus
Resetting the MATE2 to Factory Defaults
1
1 The AGS Menu is shown on the next page….
ADV/MATE/DEFAULT----------Are you sure?
YES NO
ADV/MATE/GRIDUSE--------weekday 12:00Agriduse start timeDOWN UP CHANGE
ADV/MATE/GRIDUSE--------weekday 12:00Agriduse stop timeDOWN UP CHANGE
ADV/MATE/GRIDUSE--------weekend 12:00Agriduse start timeDOWN UP CHANGE
ADV/MATE/GRIDUSE--------weekend 12:00Agriduse stop timeDOWN UP CHANGE
WEEKDAY GRIDUSE STARTadj hour 12:00A
DOWN INC DEC
WEEKDAY GRIDUSE STARTadj min 12:00A
INC DEC DONE
WEEKDAY GRIDUSE STOPadj hour 12:00A
DOWN INC DEC
WEEKDAY GRIDUSE STOPadj min 12:00A
INC DEC DONE
WEEKEND GRIDUSE STARTadj hour 12:00A
DOWN INC DEC
WEEKEND GRIDUSE STARTadj min 12:00A
INC DEC DONE
WEEKEND GRIDUSE STOPadj hour 12:00A
DOWN INC DEC
WEEKEND GRIDUSE STOPadj min 12:00A
INC DEC DONE
ADV/MATE/PG4-------------FN-DC advanced gridtie authorityPG3 MODE ADV MAIN
ADV/MATE/AGS/PG4/MODE--FN-DC enable
disabledPG4 IN DEC ADV
MAIN--------------------3:02:14P
SUM STATUS SETUP ADV
ADV/SETTINGS/WARNINGchanges made could adversely affect
system performance
ADV/PASSOWRD------------Enter the password
132ENTER INC DEC EXIT
ADV/PASSOWRD------------Enter the password
141ENTER INC DEC EXIT
A 1. Press the soft key until “141” is displayed on the LCD.
2. Press the soft key to accept the password and move forward to the Device Selection Menu.
A
B
B
MAIN-------------------3:02:14P
SUM STATUS SETUP ADV
To return to the Main screen at any time:
Press and hold the 2 left soft keys at the same time. Release when the Main screen appears.
MA
TE
(continued)
900-0131-01-00 Rev A.vsd\MATE ADV Setup 2\2012-03-21©2012 OutBack Power Technologies. All Rights Reserved. Page 4
ADV/MATE/AGS/SETUP------ags enabled: No
DOWN UP NO YES
ADV/MATE/AGS/SETUP------ags control: MAN-OFF
DOWN UP CHANGE
ADV/MATE/AGS/SETP-------dc genset: No
DOWN UP NO YES
ADV/MATE/AGS/SETUP------Vdc genstop 38.0 Vdc
DOWN UP INC DEC
ADV/MATE/AGS/SETUP------ags fault time 17
minutesDOWN UP INC DEC
ADV/MATE/AGS/SETUP------cool down time 0
minutesDOWN UP INC DEC
ADV/MATE/AGS/SETUP------warm up time 0
minutesDOWN UP INC DEC
ADV/MATE/AGS/SETP-------end of AGS Setup
menuUP TOP AGS
ADV/MATE/PAGE1choose category
HBX GRIDUSE AGS PG2
ADV/MATE/AGS------------choose category:
QUIET VOLTSETUP TIME START PG2
ADV/MATE/AGS/QUIETTIME--weekday 12:00Aquiet time startDOWN UP CHANGE
ADV/MATE/AGS/QUIETTIME--weekday 12:00Aquiet time stopDOWN UP CHANGE
ADV/MATE/AGS/QUIETTIME--weekend 12:00Aquiet time startDOWN UP CHANGE
ADV/MATE/AGS/QUIETTIME--weekend 12:00Aquiet time stopDOWN UP CHANGE
ADV/MATE/AGE/QUIETTIME--end of quiet time
menuUP TOP AGS
ADV/MATE/AGS/VSTART-----volt start 24.4 Vdc24 hr settingDOWN AGS INC DEC
ADV/MATE/AGS/VSTART-----volt start 23.6 Vdc2 hr settingDOWN UP INC DEC
ADV/MATE/AGS/VSTART-----volt start 22.0 Vdc2 min settingDOWN UP INC DEC
ADV/MATE/AGE/QTend of VOLTAGE
START menuUP TOP AGS
GEN START CONTROLcurrently: MAN-OFF
OFF AUTO ON OK
WEEKDAY QT STARTadj hour 12:00A
DOWN INC DEC
WEEKDAY QT STARTadj min 12:00A
INC DEC DONE
WEEKDAY QT STOPadj hour 12:00A
DOWN INC DEC
WEEKDAY QT STOPadj min 12:00A
INC DEC DONE
WEEKEND QT STARTadj hour 12:00A
DOWN INC DEC
WEEKEND QT STARTadj min 12:00A
INC DEC DONE
WEEKEND QT STOPadj hour 12:00A
DOWN INC DEC
ADV/MATE/AGS/SETUP------ags port: 1
DOWN AGS INC DEC
WEEKEND QT STOPadj min 12:00A
INC DEC DONE
Continued on the next page...
MAIN-------------------3:02:14P
SUM STATUS SETUP ADV
To return to the Main screen at any time:
Press and hold the 2 left soft keys at the same time. Release when the Main screen appears.
MA
TE
(continued)
900-0131-01-00 Rev A.vsd\MATE ADV Setup 3\2012-03-21©2012 OutBack Power Technologies. All Rights Reserved. Page 5
Advanced Setup Menu
(Continued)
ADV/MATE/AGS/LS---------load start 0 kw
DOWN AGS INC DEC
ADV/MATE/AGS/LS---------load start 1 mindelayDOWN UP INC DEC
ADV/MATE/AGE/LSend of LOAD START menuUP TOP AGS
ADV/MATE/AGS/LS---------load stop 0 kw
DOWN UP INC DEC
ADV/MATE/AGS/PAGE2---------choose category
LOAD MUSTPG1 START RUN PG3
ADV/MATE/AGS/MR---------weekday 12:00 Amust run start timeDOWN AGS CHANGE
ADV/MATE/AGS/MR---------weekday 12:00 Amust run stop timeDOWN UP CHANGE
ADV/MATE/AGE/MRend of MUST RUN menuUP TOP AGS
ADV/MATE/AGS/MR---------weekend 12:00 Amust run start timeDOWN UP CHANGE
ADV/MATE/AGS/MR---------weekend 12:00 Amust run stop timeDOWN UP CHANGE
ADV/MATE/AGS/LS---------load stop 1 mindelayDOWN UP INC DEC
WEEKDAY MR STARTadj hour 12:00A
DOWN INC DEC
WEEKDAY MR STOPadj hour 12:00A
DOWN INC DEC
WEEKEND MR STARTadj hour 12:00A
DOWN INC DEC
WEEKEND MR STOPadj hour 12:00A
DOWN INC DEC
WEEKEND MR STARTadj min 12:00A
INC DEC DONE
WEEKEND MR STOPadj min 12:00A
INC DEC DONE
WEEKDAY MR STARTadj min 12:00A
INC DEC DONE
WEEKDAY MR STOPadj min 12:00A
INC DEC DONEADV/MATE/AGS/%SOC-------
end of %SOC START MenuUP TOP AGS
ADV/MATE/AGS/PAGE3------choose category
%socPG2 START TIMERS PG4
ADV/MATE/AGS/TIMERS-----ags state 0
DOWN AGS
ADV/MATE/AGS/TIMERS-----agsgenfault 0
DOWN UP
ADV/MATE/AGS/TIMERS-----24 hr 1440 minvs timeDOWN UP
ADV/MATE/AGS/TIMERS-----2 hr vs time 120 min
DOWN UP
ADV/MATE/AGS/TIMERS-----2 min 2 minvs timeDOWN UP
ADV/MATE/AGS/TIMERS-----lsstart timer 0 min
DOWN UP
ADV/MATE/AGS/TIMERS-----lsstop timer 0 min
DOWN UP
ADV/MATE/AGS/PAGE4------choose category:
PG3 EXERCISE ADV
ADV/MATE/AGS/EX---------ex start day ---
DOWN AGS INC DEC
ADV/MATE/AGS/EX---------ex start time 12:00A
DOWN UP INC DEC
ADV/MATE/AGS/EX---------ex period 15 min
DOWN UP INC DEC
ADV/MATE/AGS/%SOC----------%SOC start 0%
DOWN AGS INC DEC
ADV/MATE/AGS/%SOC-------%SOC stop 90%
DOWN UP INC DEC
ADV/MATE/AGS/FULLCHG---charge to 100% fullevery 15 daysDOWN UP INC DEC
ADV/MATE/AGS/TIMERS-----exstop timer 0 min
DOWN UP
ADV/MATE/AGS/ES---------end of
exercise MenuUP TOP AGS
ADV/MATE/AGS------------choose category:
QUIET VOLTSETUP TIME START PG2
ADV/MATE/PAGE1choose category
HBX GRIDUSE AGS PG2
Continued from the previous page.
ADV/MATE/AGS/TIMERS-----Vdcstop timer 0 min
DOWN UP
ADV/MATE/AGS/TIMERS-----end of TIMERS
MenuUP TOP AGS
MAIN-------------------3:02:14P
SUM STATUS SETUP ADV
To return to the Main screen at any time:
Press and hold the 2 left soft keys at the same time. Release when the Main screen appears.
INVE
RTE
R
900-0131-01-00 Rev A.vsd\INV Setup\2012-03-21©2012 OutBack Power Technologies. All Rights Reserved. Page 6
Setting up the basic Inverter functions includes:1. Selecting the AC input (Grid or Gen).2. Setting the Search function.
SETUP/FX/INPUTAc1/grid 60.0 aaclimitDOWN INC DEC PORT
SETUP/FX/SEARCH------P01search 6sensitivityDOWN INC DEC PORT
SETUP/FX/SEARCH------P01search 8 cyclespulse lengthDOWN INC DEC PORT
SETUP/FX/SEARCH------P01search 60 cyclespulse spacingDOWN INC DEC PORT
SETUP/FX----------------choose category
SRCH INPUT
SETUP------------------choose device:
FX MATE
MAIN--------------------3:02:14P
SUM STATUS SETUP ADV
SETUP/FX/SEARCH---------search setup completed
TOP SETUP MAIN
ADV/FX/PAGE1choose category
ADV INV CHRG PG2
ADV/FX/INVERTER------P01press button 2
DoneEXIT 1 2
ADV/FX/INVERTER------P01press button 2
ReadyEXIT 1 2
ADV/FX/INVERTER------P01press button 1
ReadyEXIT 1 2
ADV/FX/INVERTER------P01choose fx portthen press nextEXIT PORT NEXT
ADV/FX/INVERTER---------reset FX to factorydefaultsDOWN MORE
ADV/FX/INVERTER---------inverter programming completed
TOP ADV MAIN
ADV/FX/CHARGER-------P01charger 12.0AaclimitDOWN INC DEC PORT
ADV/FX/CHARGER-------P01charger 12.0 AaclimitDOWN INC DEC PORT
ADV/FX/CHARGER-------P01absorb 28.8 Vdcset pointDOWN INC DEC PORT
ADV/FX/CHARGER-------P01absorb 1.0 hrstime limitDOWN INC DEC PORT
ADV/FX/CHARGER-------P01float 27.2 Vdcset pointDOWN INC DEC PORT
Continued on next page….
NOTE: The values shown in this illustration will vary depending on the model of inverter.
Setpoints:GridGenerator
1
ADV/FX/INVERTER-----P01search 6sensitivityDOWN INC DEC PORT
ADV/FX/INVERTER-----P01search 8pulse lengthDOWN INC DEC PORT
ADV/FX/INVERTER-----P01search 8 cyclespulse lengthDOWN INC DEC PORT
ADV/FX/INVERTER------P01search 60 cyclespulse spacingDOWN INC DEC PORT
ADV/FX/INVERTER------P01low battery 21.0 Vdccutout set pointDOWN INC DEC PORT
ADV/FX/INVERTER------P01low battery 25.0 Vdccutin set pointDOWN INC DEC PORT
ADV/FX/CHARGER-------P01float 1.0 hrstime limitDOWN INC DEC PORT
ADV/FX/CHARGER-------P01equalize 1.0 hrstime limitDOWN INC DEC PORT
ADV/FX/CHARGER-------P01equalize 28.8 Vdcset pointDOWN INC DEC PORT
ADV/FX/CHARGER-------P01charger programming
completedTOP ADV MAIN
Main Screen
ADV/FX/INVERTER------P01adjust 120 Vacoutput voltageDOWN INC DEC PORT
Accessing the Advanced Menu:
ADV--------------------choose device
FX CC DC MATE
Changing more detailed operating parameters requires access to the Advanced Setup Menu.
MAIN--------------------3:02:14P
SUM STATUS SETUP ADV
Main Screen
Advanced Menu for Inverter (Page 1 of 3)
ADV/FX/CHARGER-------P01refloat 25.0 Vdcset pointDOWN INC DEC PORT
Resetting the Inverter to Factory Defaults
SETUP/FX/INPUT-------P01ac transfer controlDOWN GRID GEN PORT
1
SETUP/FX/INPUTAc2/gen 30.0 aaclimitDOWN INC DEC PORT
SETUP/FX/INPUT---------Input setup completed
TOP SETUP MAIN
MAIN--------------------3:02:14P
SUM STATUS SETUP ADV
ADV/SETTINGS/WARNINGchanges made could adversely affect
system performance
ADV/PASSOWRD------------Enter the password
132ENTER INC DEC EXIT
ADV/PASSOWRD------------Enter the password
141ENTER INC DEC EXIT
A 1. Press the soft key until “141” is displayed on the LCD.
2. Press the soft key to accept the password and move forward to the Device Selection Menu.
A
B
B
To return to the Main screen at any time:
MAIN-------------------3:02:14P
SUM STATUS SETUP ADV
Press and hold the 2 left soft keys at the same time. Release when the Main screen appears.
INVE
RTE
R
(continued)
900-0131-01-00 Rev A.vsd\INV Setup 2\2012-03-21©2012 OutBack Power Technologies. All Rights Reserved. Page 7
ADV/FX/PAGE2--------P01choose category
ADV GRID GEN PG3
ADV/FX/GRID---------P01ac 1/grid 108 Vac lower limitDOWN INC DEC PORT
ADV/FX/GRID---------P01ac 1/grid 140 Vacupper limitDOWN INC DEC PORT
ADV/FX/GRID---------P01ac 1/grid 48.0 Aacinput limitDOWN INC DEC PORT
ADV/FX/GRID---------P01ac 1/grid 6 cyclestransfer delayDOWN INC DEC PORT
ADV/FX/GRID---------P01grid programming
completedTOP ADV MAIN
ADV/FX/GEN----------P01gen input 00.5 minconnect delayDOWN INC DEC PORT
ADV/FX/GEN----------P01ac 2/gen 108 Vaclower limitDOWN INC DEC PORT
ADV/FX/GEN----------P01ac 2/gen 140.0 Aacupper limitDOWN INC DEC PORT
ADV/FX/GEN----------P01ac 2/gen 48.0 Aacinput limitDOWN INC DEC PORT
ADV/FX/GEN----------P01ac 2/gen ONsupportDOWN INC DEC PORT
ADV/FX/GEN----------P01ac 2/gen 60cycles transfer delayDOWN INC DEC PORT
ADV/FX/GEN----------P01gen programming
completedTOP ADV MAIN
ADV/FX/PAGE4---------P01choose category
PG3 SELL CAL MAIN
ADV/FX/SELL----------P01sell re 23.6 VdcvoltsDOWN INC DEC PORT
ADV/FX/SELL----------P01grid tie IEEEwindowDOWN IEEE USER PORT
ADV/FX/SELL----------P01selling
setup completedTOP ADV MAIN
ADV/FX/SELL----------P01grid tie GRIDTIEauthorityDOWN IEEE USER PORT
ADV/FX/AUX-----------P01loadshed 22.0 Vdcoff set pointDOWN INC DEC PORT
ADV/FX/AUX-----------P01vent fan 26.0 Vdcon set pointDOWN INC DEC PORT
ADV/FX/AUX-----------P01vent fan off 5 minperiodDOWN INC DEC PORT
ADV/FX/AUX-----------P01diversion 29.2 Vdcon set pointDOWN INC DEC PORT
ADV/FX/AUX-----------P01diversion 30 secoff delayDOWN INC DEC PORT
ADV/FX/AUX-----------P01aux output
setup completedTOP ADV MAIN
ADV/FX/PAGE3---------P01choose category
PG2 AUX STACK PG4
ADV/FX/AUX-----------P01aux output AUTOcontrolDOWN INC DEC PORT
ADV/FX/AUX-----------P01aux output cool fanfunctionDOWN INC DEC PORT
ADV/FX/AUX-----------P01genalert 22.0 Vdcon setpointDOWN INC DEC PORT
ADV/FX/AUX-----------P01genalert 4 minon delayDOWN INC DEC PORT
ADV/FX/AUX-----------P01genalert 28.0 Vdcoff set pointDOWN INC DEC PORT
ADV/FX/AUX-----------P01genalert 9 minoff delayDOWN INC DEC PORT
ADV/FX/CALIBRATE-----P01Vac input 120 vacadjustmentDOWN INC DEC PORT
ADV/FX/CALIBRATE-----P01Vac output 120 VacadjustmentDOWN INC DEC PORT
ADV/FX/CALIBRATE-----P01calibration
setup completedTOP ADV MAIN
ADV/FX/CALIBRATE-----P01battery Vdc 25.4 VdcadjustmentDOWN INC DEC PORT
Advanced Inverter Setup Menu (continued)
NOTE: The values shown in this illustration will vary depending on the model of inverter.
ADV/FX/PAGE1choose category
ADV INV CHRG PG2
ADV/FX/STACK---------P01stack 1-2PH MasterphaseDOWN INC DEC PORT
ADV/FX/STACK---------P01stack Classic SlavephaseDOWN INC DEC PORT
ADV/FX/STACK---------P01stack OB Slave L1phaseDOWN INC DEC PORT
ADV/FX/STACK---------P01stack OB Slave L2phaseDOWN INC DEC PORT
ADV/FX/STACK---------P01stack 3PH MasterphaseDOWN INC DEC PORT
ADV/FX/STACK---------P01stack 3 PH SlavephaseDOWN INC DEC PORT
ADV/FX/STACK---------P01power save level 0master adjust onlyDOWN INC DEC PORT
MAIN--------------------3:02:14P
SUM STATUS SETUP ADV
ADV/FX/STACK---------P01stacking
setup completedTOP ADV MAIN
ADV/FX/STACK---------P01power save level 0slave adjust onlyDOWN INC DEC PORT
Continued from previous page….
Page 2
Page 3
Page 4
Page 1MAIN-------------------
3:02:14P
SUM STATUS SETUP ADV
To return to the Main screen at any time:
Press and hold the 2 left soft keys at the same time. Release when the Main screen appears.
CH
AR
GE
CO
NTR
OLL
ER
900-0131-01-00 Rev A.vsd\CC Setup on MATE\2012-03-21©2012 OutBack Power Technologies. All Rights Reserved. Page 8
Accessing the Advanced Menu:
Changing more detailed operating parameters requires access to the Advanced Setup Menu. Advanced Menu for the
FLEXmax Charge Controller (Page 1 of 2)
ADV/CC/CHGR----------P02output current 80.0 A limitDOWN INC DEC PORT
ADV/CC/ADVANCED------P02MPPT mode auto trackDOWN INC DEC PORT
ADV/CC/ADVANCED------P02grid tie mode
nonGTDOWN INC DEC PORT
ADV/CC/ADVANCED------P02park MPP 77.0%
DOWN INC DEC PORT
ADV/CC/ADVANCED------P02Mpp range limit %VOCmaximum 90%DOWN INC DEC PORT
ADV/CC/ADVANCED------P02rebulk voltage
24.8 VdcDOWN INC DEC PORT
ADV/CC/ADVANCED------P02vbatt calibration
29.3 Vdc 0.0 VdcDOWN INC DEC PORT
ADV/CC/ADVANCED------P02RTS compensation
wideDOWN INC DEC PORT
ADV/CC/ADVANCED------P02RTS comp limitupper limit 28.2 VdcDOWN INC DEC PORT
ADV/CC/EQ------------P02eq voltage 28.8 VOC
DOWN INC SETUP ADV
ADV/CC/EQ------------P02eq time 1 hours
DOWN INC SETUP ADV
ADV/CC/EQ------------P02 end CC eq menu
TOP ADV MAIN
ADV/CC/EQ------------P02eq auto eq interval
0 daysDOWN INC SETUP ADV
ADV/CC/AUX-----------P02vent fan
DOWN INC SET PORT
ADV/CC/AUX-----------P02aux control OFF
DOWN ON OFF PORT
ADV/CC/aux-----------P02 end of menu
TOP ADV MAIN
ADV/CC/CHRG----------P02absorb voltage 28.8 V
DOWN INC DEC PORT
ADV/CC/CHRG----------P02float voltage 27.2 V
DOWN INC DEC PORT
ADV/FX/CHRG----------P02 end charger menu
TOP ADV MAIN
ADV/CC/ADVANCED------P02snooze mode
FLEX
net D
C
900-0131-01-00 Rev A.vsd\FNDC\2012-03-21©2012 OutBack Power Technologies. All Rights Reserved. Page 9
Main ScreenMAIN----------------
3:02:14P
SUM STATUS SETUP ADV
E -------------- FBattery Discharging
State of Charge 100%
DC Now 25.4V 100%IN 0.4A 0.010kWOUT 1.6A 0.040kWBAT -1.2A -0.030kW
DC Today minSOC 97%In 247AH 12.84kWHOut 240AH 12.50kWHBat 7AH 0.34kWH
DC BAT 25.4V 100%Bat -0.3A -0.010kWNet 0.4AH 0.00kWHDays Since Full 1.1
FX Total 25.4V 97%Inverting 0.000kWAC Loads 0.000kWBuying $ 0.000kW
State-of-Charge Screen
Summary Screen #1
Summary Screen #2
Summary Screen #3
Summary Screen #4
Press this soft key to proceed. This screen will also automatically move forward after a user-defined period of time.
1
1
1
1
STATUS------------------choose device:
FX CC DC MAIN
MAIN--------------------3:02:14P
SUM STATUS SETUP ADV
Main Screen
NOTE: The values shown in this illustration will vary depending on the model of inverter.
STATUS/DC/PAGE 1-------
STATSMETER SHUNT BATT PG2
A: 0.1 A 0.001 kWB: 0.0 A 0.000 kWC: 0.0 A 0.000 kWDOWN STATUS
A: -1 Ah 0.100 kWHB: 0 Ah 0.000 kWHC: 0 Ah 0.000 kWHDOWN UP TOP
METER/DC/SHUNT Aremoved
12 AH 0.16 kWHDOWN UP TOP
METER/DC/SHUNT Acharged
12 AH 0.16 kWHDOWN UP TOP
STATUS/DC/SHUNT Amax removedamps 0.9DOWN UP RESET TOP
STATUS/DC/SHUNT Amax removedkWatts 0.010DOWN UP RESET TOP
STATUS/DC/SHUNT Amax chargedamps 10.1DOWN UP RESET TOP
STATUS/DC/SHUNT Amax chargedkWatts 0.129DOWN UP RESET TOP
STATUS/DC/SHUNT Bmax removedamps 0DOWN UP RESET TOP
STATUS/DC/SHUNT Bmax chargedamps 30.2DOWN UP RESET TOP
STATUS/DC/SHUNT Bmax chargedkWatts 2.040DOWN UP RESET TOP
STATUS/DC/BATTtotal days at 100%
0.5DOWN UP RESET TOP
STATUS/DC/BATTdays since chargeparameters met 5.9DOWN UP TOP
STATUS/DC/BATTbattery min today
24.8 VdcDOWN UP RESET TOP
STATUS/DC/SHUNT Bmax chargedamps 39.8DOWN UP RESET TOP
METER/DC/SHUNT Bremoved
0 AH 0 kWHDOWN UP TOP
METER/DC/SHUNT Bcharged
12 AH 0.16 kWHDOWN UP TOP
METER/FN/METERDC firmware revision
000.00/040DOWN UP TOP
STATUS/DC/SHUNTend of shuntstatus menu
UP TOP STATUS
STATUS/DC/BATTbattery max today
25.4 VdcDOWN UP RESET TOP
STATUS/DC/BATTtemp comp’d battsetpoint 28.4 VdcDOWN UP TOP
STATUS/DC/BATTsystem batterytemperature 29°CDOWN UP TOP
STATUS/DC/BATTcycle chargefactor 78%DOWN UP TOP
STATUS/DC/BATTcycle kWhr chargeefficiency 65%DOWN UP TOP
STATUS/DC/BATTlifetime kAH removed 5
DOWN UP RESET TOP
STATUS/DC/BATTend of batterystatus menuUP TOP STATUSMETER/FN/METER
end of meter menu
UP TOP STATUS
STATUS/DC/SHUNT Cmax removedamps 0DOWN UP RESET TOP
STATUS/DC/SHUNT Cmax chargedamps 30.2DOWN UP RESET TOP
STATUS/DC/SHUNT Cmax chargedkWatts 2.040DOWN UP RESET TOP
STATUS/DC/SHUNT Cmax chargedamps 39.8DOWN UP RESET TOP
METER/DC/SHUNT Cremoved
0 AH 0 kWHDOWN UP TOP
METER/DC/SHUNT Ccharged
0 AH 0.00 kWHDOWN UP TOP
STATUS/DC/PAGE2--------
PG1 AUX MAIN
STATUS/DC/AUX---------aux control
manualDOWN STATUS
STATUS/DC/PAGE2-------aux relay state: OFF
UP STATUS
These screens are informational only. No changes can be made from this location in the Menu Map.
MAIN-------------------3:02:14P
SUM STATUS SETUP ADV
To return to the Main screen at any time:
Press and hold the 2 left soft keys at the same time. Release when the Main screen appears.
(continued)
900-0131-01-00 Rev A.vsd\FNDC Adv\2012-03-21©2012 OutBack Power Technologies. All Rights Reserved. Page 10
NOTE: The values shown in this illustration will vary depending on the model of inverter.
ADV/DC/BAT----------P03battery capacity110 amphoursTOP INC DEC ADV
ADV/DC/PAGE1choose category
ADV BAT SHUNT PG2
ADV/DC/SHUNT--------P03shunt A mode enabled
DOWN EN DIS TOP
ADV/DC/SHUNT--------P03shunt B mode enabled
DOWN EN DIS TOP
ADV/DC/SHUNT--------P03shunt C mode disabled
DOWN EN DIS TOP
ADV/DC/SHUNT--------P03shunt setup complete
TOP ADV MAIN
ADV/DC/PG2choose category
PG1 CHARGE AUX PG3
ADV/DC/CHARGEreturn amps 10.4
DOWN INC DEC TOP
ADV/DC/CHARGEbattery voltage 26.0
DOWN INC DEC TOP
ADV/DC/CHARGEparameters met time
1 minutesDOWN INC DEC TOP
ADV/DC/CHARGEcharge factor 93%
DOWN INC DEC TOP
ADV/DC/AUXCONTROLcurrently MAN-OFF
DOWN OFF AUTO ON
ADV/DC/AUXCONTROLhigh volts 29.0 Vdc
DOWN INC DEC TOP
ADV/DC/AUXCONTROLlow volts 22.0 Vdc
DOWN INC DEC TOP
ADV/DC/AUXCONTROLSOC high 90%
DOWN INC DEC TOP
ADV/DC/AUXCONTROLSOC low 59%
DOWN INC DEC TOP
ADV/DC/AUXCONTROLhigh set point delay
1 minutesDOWN INC DEC TOP
ADV/DC/AUXCONTROLlow set point delay
1 minutesDOWN INC DEC TOP
ADV/DC/AUXCONTROLinvert logic YES
DOWN YES NO TOP
ADV/DC/AUXCONTROLaux parameterscomplete
TOP ADV MAIN
Accessing the Advanced Menu:
MAIN--------------------3:02:14P
SUM STATUS SETUP ADV
ADV/SETTINGS/WARNINGchanges made could adversely affect
system performance
ADV/PASSWORD------------Enter the password
132ENTER INC DEC EXIT
ADV/PASSWORD------------Enter the password
141ENTER INC DEC EXIT
ADV--------------------choose device
FX CC DC MATE
MAIN--------------------3:02:14P
SUM STATUS SETUP ADV
ADV/DC/PG3---------P03choose category
PG2 RESET CLR MAIN
ADV/DC/RESET-------P03reset DC to factorydefaults?
NO YES TOP
ADV/DC/CLEARclear data logmemory?
YES NO TOP
FLEX
net D
C
ADV/DC/CHARGEcharge parameterscomplete
TOP ADV MAIN
MAIN-------------------3:02:14P
SUM STATUS SETUP ADV
To return to the Main screen at any time:
Press and hold the 2 left soft keys at the same time. Release when the Main screen appears.
About OutBack Power TechnologiesOutBack Power Technologies is a leader in advanced energy conversion technology. Our products include true sine wave inverter/chargers, maximum power point tracking charge controllers, and system communication components, as well as circuit breakers, batteries, accessories, and assembled systems.
Contact InformationTelephone: +1.360.435.6030 (Main)
+1.360.618.4363 (Technical Support)+1.360.435.6019 (Fax)
Mailing Address: OutBack Power Technologies Sales & Marketing5917 - 195th Street N.E. 6115 – 192nd Street NEArlington, WA 98223 USA Arlington, WA 98223 USA
E-mail: Support@outbackpower.com
Web Site: www.outbackpower.com
DisclaimerUNLESS SPECIFICALLY AGREED TO IN WRITING, OUTBACK POWER TECHNOLOGIES:
(a) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION.
(b) ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSS OR DAMAGE, WHETHER DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION. THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER’S RISK.
Warranty SummaryOutBack Power Technologies warrants that the products it manufactures will be free from defects in materials and workmanship for a period of five (5) years subject to the conditions set forth in the warranty detail, found in the product manual.
OutBack Power Technologies cannot be responsible for system failure, damages, or injury resulting from improper installation of their products.
Notice of CopyrightMATE Series Overview © January 2012 by OutBack Power Technologies. All Rights Reserved.
TrademarksOutBack Power is a registered trademark of OutBack Power Technologies.
Date and RevisionJanuary 2012, Revision A
Part Number900-0131-01-00 Rev A
North America:5917 - 195th Street N.E. Arlington, WA USA+1.360.435.6030900-0131-01-00 Rev A
/ColorImageDict > /JPEG2000ColorACSImageDict > /JPEG2000ColorImageDict > /AntiAliasGrayImages false /CropGrayImages true /GrayImageMinResolution 150 /GrayImageMinResolutionPolicy /OK /DownsampleGrayImages false /GrayImageDownsampleType /Bicubic /GrayImageResolution 150 /GrayImageDepth -1 /GrayImageMinDownsampleDepth 2 /GrayImageDownsampleThreshold 1.50000 /EncodeGrayImages true /GrayImageFilter /DCTEncode /AutoFilterGrayImages true /GrayImageAutoFilterStrategy /JPEG /GrayACSImageDict > /GrayImageDict > /JPEG2000GrayACSImageDict > /JPEG2000GrayImageDict > /AntiAliasMonoImages false /CropMonoImages true /MonoImageMinResolution 1200 /MonoImageMinResolutionPolicy /OK /DownsampleMonoImages false /MonoImageDownsampleType /Bicubic /MonoImageResolution 1200 /MonoImageDepth -1 /MonoImageDownsampleThreshold 1.50000 /EncodeMonoImages true /MonoImageFilter /CCITTFaxEncode /MonoImageDict > /AllowPSXObjects false /CheckCompliance [ /None ] /PDFX1aCheck false /PDFX3Check false /PDFXCompliantPDFOnly false /PDFXNoTrimBoxError true /PDFXTrimBoxToMediaBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXSetBleedBoxToMediaBox true /PDFXBleedBoxToTrimBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXOutputIntentProfile (None) /PDFXOutputConditionIdentifier () /PDFXOutputCondition () /PDFXRegistryName () /PDFXTrapped /False