Supply Voltage Degradation Aware Analytical Placement
Andrew B. Kahng, Bao Liu and Qinke Wang
UCSD CSE Department{abk, bliu, qiwang}@cs.ucsd.edu
2
Outline
• Introduction– Motivation– Related work– Our work– Problem formulation
• Analysis and Observations
• Voltage Degradation Aware Placement
• Experiments
• Conclusions
3
Motivation
• Increasingly significant voltage degradation along power networks in nanometer VLSI designs– shrinking layout feature sizes– increasing device density
• Logic malfunction
• Performance degradation– a 10% voltage drop could be responsible for 10%
transistor performance degradation, and the effect is super-linear
4
Related Work• Techniques to reduce supply voltage
degradation– wiresizing and edge augmentation– decoupling capacitor insertion – circuit de-tuning
• Placement and floorplan related techniques– local placement adjustment to allocate
whitespace for decoupling capacitor insertion– allocation of power pads: more pads close to
current drain hot spots– a floorplan objective for power network
construction and supply voltage drop
5
Summary of Existing Works
• Existing voltage drop reduction techniques focus on power supply network design
• Supply voltage degradation is also a function of supply currents of the circuit
• To the best of our knowledge, no analytical placement technique for voltage drop reduction is proposed
6
Our Contributions
• We propose voltage degradation aware placement : relocating current drains for voltage drop reduction– represent voltage drop at a power node as a
function of current drains and effective resistances
– propose voltage drop as placement objective and integrate into an analytical placement framework
– test our method on real designs with industry flow
7
Model of Power Network
• Power network: modeled as a resistive netlist• parallel metal wires at multiple layers• metal layers connected at crossing points by vias
• Power pads on the top layer: modeled as DC voltage sources
• Active devices at the bottom layer: modeled as DC current drains – DC currents provide bounds for the actual AC
currents
8
Problem Formulation
• Given – a power supply network– worst-case current drains for each cell
• Find a placement to– reduce supply voltage drop – maintain comparable placement wirelength,
area, and timing performance
9
Outline
• Introduction
• Analysis and Observations– Analysis of voltage drop– Observations on voltage drop optimization– Computation of effective resistance
• Voltage Degradation Aware Placement
• Experiments
• Conclusions
10
Analysis of Voltage Drop
• Voltage drop at an observation node t
– each current drain Ik has contribution to the
voltage drop– : effective resistance for a current drain
at node k to inject noise voltage at node t
11
An Example Tree-Structure
R2
R1
R3
s
t
I1
I2 I3
• s : power pad
• t : observation node
12
Objectives and Observations • Given a power supply network, find a
placement of current drains to minimize:– (a) voltage drop at a given observation node t– (b) average voltage drop of all nodes, or – (c) max voltage drop over all nodes
• (a) : greedy algorithm to locate largest current Ik first to have smallest resistance
• (b) : greedy algorithm to locate largest current Ik first to have smallest resistance
• (c) : NP-hard
13
Effective Resistance (I)
• Direct modified nodal analysis
– G: conductance matrix – matrix inversion O(n3)– not feasible for practical power networks
14
Effective Resistance (II)
• Random walk [Qian et al. DAC 2003]– resistance of the common part of two random
walk paths that respectively start from nodes k and t and end at a power pad
– a random walk path follows the corresponding current distribution probability: transition probability from node p to q on the random walk path is
15
Effective Resistance (III)
• Better scalability and efficiency– contract power netlist by merging bottom-level
wires and computing parallel resistances– compute effective resistance between
observation nodes – apply bi-linear interpolation for supply voltage
drop at any node
16
Outline
• Introduction
• Analysis and Observations
• Voltage Degradation Aware Placement– Introduction of analytical placement– Voltage drop aware placement objectives– Implementation
• Experiments
• Conclusions
17
Introduction of APlace (I)• APlace: a general analytical placement framework• High solution quality and strong extensibility• Regard Global placement (NP-hard) as a
Constrained Nonlinear Optimization Problem:
– : density function that equals the total module area in a global cell g
– D : average module area over all global cells
18
Introduction of APlace (II)• Apply smooth approximation of placement
objectives: wirelength, density function, etc.• Quadratic Penalty method
– solve a sequence of unconstrained minimization problems for a sequence of µ ↓ 0
• Conjugate Gradient solver– find an unconstrained minimum of a high-dimensional
function– memory required is only linear in the problem size,
which makes it adaptable to large-scale placement problems
19
Outline
• Introduction
• Analysis and Observations
• Voltage Degradation Aware Placement– Introduction of analytical placement– Voltage drop aware placement objectives– Implementation
• Experiments
• Conclusions
20
Average Voltage Drop
• N : the number of observation nodes• : effective resistance for a
current drain Iv to generate a voltage-drop at node g– function of module v's position during global
placement– effective resistance at continuous positions are
obtained using bi-linear interpolation– partial differentials are computed accordingly
21
Worst Voltage Drop
• LOG-SUM-EXP function – smooth approximation of worst voltage drop– α: smoothing parameter and significance
criterion for choosing power network nodes with large voltage drop to minimize
– Vworst: strictly convex, continuously differentiable and converges to the worst voltage drop as α converges to 0
22
Outline
• Introduction
• Analysis and Observations
• Voltage Degradation Aware Placement– Introduction of analytical placement– Voltage drop aware placement objectives– Implementation
• Experiments
• Conclusions
23
Implementation (I)
• Integrate voltage drop objectives into the analytical placement framework
• Wv : weight of the voltage drop objective– computed according to the gradients derived
from the wirelength and voltage drop terms – scaled voltage drop gradients comparable to
wirelength gradients
24
Implementation (II)
• β : voltage drop ratio– decide the ratio of voltage drop gradients to
wirelength gradients– provide a knob to trade-off between voltage
drop and wirelength objectives for the placer
25
Outline
• Introduction
• Analysis and Observations
• Voltage Degradation Aware Placement
• Experiments– Experimental setup– Results
• Conclusions
26
Experimental Setup
• Two industry circuits– TSMC library– six metal layers– power/ground ring at top 2 layers – 4 power pads at the center of boundaries– AES: 5 stripes at M2– PCI: 4 stripes at M6 and 5 large fixed macros
Design #Cells #Rows Tech UtilizationAES 13397 129 90nm 0.6PCI 7128 251 180nm 0.43
27
Experimental Flow• Design inputs: synthesized
netlists, technology libraries, timing constraints and floorplans
• Power planning and routing, and pad placement in Cadence SoC Encounter
• Voltage drop aware and oblivious placements using our placer and wirelength-driven APlace
• Fast global and detail routing by Cadence TrialRoute
• Steady-state voltage-drop analysis by Cadence VoltageStorm
Power PlanningPower Route
Pad Place
Voltage Degradation Aware Place
Trial Route
Extract RC
Power Analysis
IR-Drop
Design
28
Outline
• Introduction
• Analysis and Observations
• Voltage Degradation Aware Placement
• Experiments– Experimental setup– Results
• Conclusions
29
Results (I): Worst Voltage Drop Results of worst voltage-drop aware placements with a variety of voltage drop ratios (β 's)Design Placers Vdrop
Ratio CPU
(V) (%) (V) (%) (e8) (%) (s)
AES APlace 0.00 0.233 0.00% 0.406 0.00% 9.48 0.00% 223.62
our placer 0.05 0.217 6.61% 0.354 12.74% 9.58 -1.10% 286.53
0.10 0.219 6.02% 0.356 12.41% 9.57 -0.94% 265.94
0.15 0.214 8.07% 0.331 18.49% 9.67 -1.95% 239.52
0.20 0.208 10.67% 0.318 21.59% 9.68 -2.09% 227.24
0.25 0.209 10.22% 0.314 22.65% 9.78 -3.17% 217.53
PCI APlace 0.00 0.026 0.00% 0.051 0.00% 19.95 0.00% 120.97
our placer 0.05 0.025 3.18% 0.048 5.54% 20.14 -0.93% 172
0.10 0.025 5.84% 0.046 9.75% 20.25 -1.50% 166
0.15 0.024 9.27% 0.044 13.67% 20.53 -2.92% 156
0.20 0.023 11.52% 0.042 16.65% 20.72 -3.87% 145
0.25 0.023 13.08% 0.041 19.02% 21.01 -5.33% 146
Vdrop Improvements Impact
Avg Vdrop Max Vdrop HPWL
(β)
30
Design Placers Vdrop
Ratio CPU
(V) (%) (V) (%) (e8) (%) (s)
AES APlace 0.00 0.233 0.00% 0.406 0.00% 9.48 0.00% 223.62
our placer 0.05 0.219 6.13% 0.361 11.12% 9.50 -0.23% 284.27
0.10 0.210 9.79% 0.343 15.48% 10.04 -5.88% 273.32
0.15 0.209 10.19% 0.341 16.07% 10.12 -6.76% 319.44
0.20 0.201 13.68% 0.320 21.24% 10.28 -8.46% 311.6
0.25 0.192 17.64% 0.302 25.70% 10.40 -9.74% 285.58
PCI APlace 0.00 0.026 0.00% 0.051 0.00% 19.95 0.00% 120.97
our placer 0.05 0.025 4.94% 0.047 6.75% 20.22 -1.35% 160
0.10 0.024 9.14% 0.044 13.06% 21.04 -5.44% 175
0.15 0.019 26.03% 0.035 29.80% 22.83 -14.45% 206
0.20 0.018 31.02% 0.033 35.14% 23.18 -16.18% 234
0.25 0.016 39.54% 0.028 43.99% 25.16 -26.10% 285
Vdrop Improvements Impact
Avg Vdrop Max Vdrop HPWL
Results (II): Average Voltage Drop
Results of average voltage-drop aware placements with a variety of voltage drop ratios (β 's)
(β)
31
Summary of Results
• Improvement– worst voltage drop: 22.7% and 19.0% – average voltage drop: 10.2% and 13.1%
• Impact on HPWL: -3.2% and -5.3%
• Worst voltage drop objective leads to better results than average voltage drop objective– large voltage drops are among the first to be
reduced– benefit the average voltage drop more than trying
to reduce all the voltage drops with same efforts
32
HPWL vs. Voltage Drop
-5.00%
0.00%
5.00%
10.00%
15.00%
20.00%
25.00%
0.00 0.05 0.10 0.15 0.20 0.25 0.30
Voltage Degradation Ratio
Imp
rove
men
t
Avg Vdrop
Max Vdrop
HPWL
HPWL, worst-case and average voltage-drop improvements as functions of voltage drop
ratio for AES
33
Conclusions
• We propose analytical placement for supply voltage drop reduction
• We integrate supply voltage drop objective into an analytical placement framework
• Our experimental results show on average 20.9% improvement of worst-case voltage drop and 11.7% improvement of average voltage drop with only 4.3% wirelength increase
• Ongoing research efforts: supply voltage drop aware timing-driven placement