Post on 15-Mar-2022
HOW WE CAN HELP
Online
General Info & Questions
Design Team Services
Build your own Flex raceway system using our innovative web tool on the Connectrac website!
Click around and play in this online experience while learning the basics of how Flex works.
connectrac.com/build-your-own
Contact us any time! | 877.480.5637 | info@connectrac.com | connectrac.com
Connectrac® believes in providing exceptional customer service by offering unique resources like our Design Team.
These industry specialists are available to help you specify the best Flex solution for your next project.
connectrac.com/design-services
TABLE OFCONTENTS
What is Flex?How it WorksGet StartedFlex Data Capacity
Pg 4Pg 6Pg 8Pg 9
FLEX SYSTEMFor installation under carpet tile
Connectrac® Flex is...A floor-based power and data distribution system that allows users to quickly add connectivity or change power locations in a snap.
Any Space. Any Building. Any Time.™
HUDDLE
MEET
WORK
4
Interchangeable Power DevicesQuickly snap into any Power Hub location
Connects Powertracs & provides access for power devices
Top Cover & Transition Ramps
(included with raceway)Entrance Fitting
Raceway
Quick connector powers entire raceway & allows
data to enter
Powertrac
Power Hub
Pre-wired raceway segment
Data Device
Explore the graphic to learn more about the Flex system for installation under carpet tile.
HOW IT WORKS
A
B
C
C
Snaps into the raceway to provide data
connectivity
6
FLEX DATA C
APACITY
0-4 cables
5-14 cables
15-24 cables
Turn to Next Page
Turn to Page 16
Turn to Page 22
Plan Flex Raceway System
Optimize Your Raceway Increase your system’s adaptability by adding more points of power access.
GET
STA
RTED
What is the current use of this space? What else might it be used for in the future? How might furniture be rearranged?
TIP: For greater flexibility at minimal cost, add more Power Hubs and connect shorter Powertracs.
Power Hubs = access points for power devices
TIP: Visualize how your space might adapt and evolve over time.
GOOD
BETTER
BEST4
POWER HUBS
3POWER
HUBS
2POWER
HUBS
3’ 3’ 3’
3’6’
6’ 6’
3’
3’
Typical for conference rooms
Typical for up to seven workstations
Typical for up to twelve workstations
How much data do you need?
8 9
FLEX EXAMPLE RUN
In-Wall Entrance Fitting Surface-Mounted Entrance Fitting
Entrance FittingA Choose how your Flex raceways start at the wall.
1
22
11
1
In-Wall Entrance Fitting(15’ pre-wired conduit)
4’ PowertracPower Hub
HubcapReceptacle Device (2-circuit 1, 2-circuit 2)
Data Device
A1.15
B.FX1.4B.HUB
C.HUBCAPC.PW1.12
C.DT2
QTY DESCRIPTIONFLEX CODE
FLEX 0-4 Data C
ables
Entrance FittingA
Raceway B
DevicesC
Flex 0-4 Data Cables
PowertracB.FX1.4
In-Wall Entrance Fitting
A1.15
PowertracB.FX1.4
Power HubB.HUB
Power HubB.HUB
HubcapC.HUBCAP
Data DeviceC.DT2
Receptacle Device
C.PW1.12
Wall Entrance Fitting
A1A2
A
Included with every raceway order:
Top Covers
End Ramps
Transition Ramps
Transition accessories included
Surface-Mounted Entrance FittingIn-Wall Entrance Fitting A2.__A1.__
DESCRIPTIONDESCRIPTION FLEX CODEFLEX CODE
Use when cabling is running OUTSIDE the wall:Use when cabling is running INSIDE the wall:
A2.3A2.15A2.30
A1.15A1.30
3’ pre-wired conduit, 2’ Walltrac15’ pre-wired conduit, 12’ Walltrac30’ pre-wired conduit, 12’ Walltrac
15’ pre-wired conduit30’ pre-wired conduit
Base Trim included
TIP: Use A2.3 to connect to existing wall outlet boxes.
10 11
Powertracs Power Hub
RacewayB Continue to build your raceways by connecting Powertracs and Power Hubs. Equip your Flex raceway system with power & data devices.
TIP: For greater flexibility at minimal cost, add more Power Hubs and connect shorter Powertracs.
*Powertrac measurements are based on the on-center distance between the Entrance Fitting and/or Power Hubs.
Power HubB.FX1.__
B.FX1.EXT
B.FX1.90
B.HUB C.HUBCAP
C.PW1.__
C.PW2.4
DESCRIPTION DESCRIPTIONFLEX CODE FLEX CODE
Powertrac
Powertrac Extender
Powertrac Corner
Power Hub
FLEX
0-4
Dat
a C
able
s FLEX 0-4 Data C
ablesPower Devices
DevicesCChoose which devices (if any) you want to snap into your Power Hubs.
Powertrac
Powertrac Extender
Powertrac Corner
DESCRIPTIONFLEX CODE
Creates a walkable surface and makes power easily accessible for future needs
Quad device available in various 4-circuit options:
4-circuit monument that connects to most furniture base feeds
Pre-wired raceway segmentsavailable in standard lengths:
Connects Powertracs & provides access for power devices
Adds 6” to any of our standard Powertrac lengths
Top Covers & Ramps included
Allows raceway to make a 90° turn
C.PW1.11C.PW1.22C.PW1.33C.PW1.44C.PW1.12*C.PW1.34*C.PW1.14*
B.FX1.2B.FX1.3B.FX1.4B.FX1.5B.FX1.6
2’ Powertrac3’ Powertrac4’ Powertrac5’ Powertrac6’ Powertrac
All circuit 1All circuit 2All circuit 3All circuit 42-circuit 1, 2-circuit 22-circuit 3, 2-circuit 42-circuit 1, 2-circuit 4
Hubcap
Power Hub4’ Powertrac*4’ Powertrac* Power Hub
Receptacle DeviceCB
Receptacle Device
Hardwire Device
Hubcap
Power devices are all interchangeable and can be hot-swapped
when desired.
Hubcap
Receptacle Device
Hardwire Device
Power Hub Power Hub
*Controlled devices available (see Technical Guide for more details)
12 13
Data Devices
DevicesCThese devices go anywhere on the raceway.
Data DeviceC
Equip your Flex raceway system with power & data devices.
C.DT1
C.DT2
DESCRIPTIONFLEX CODE
Allows cables to enter/exit raceway
Fits up to 8 low-voltage keystone modules
Grommet
Data Device
Data DeviceGrommet
Data devices easily snap next to any
power device.
Optional Accessories Enhance your raceways with these additional options.
Extra HubcapVertical Wire Manager Rough-In Frame
VWM
RIF
C.HUBCAP
DESCRIPTIONFLEX CODE
Attaches to any power or data device to manage cabling
Installed before drywall to provide a rough opening for cabling
Creates a walkable surface and makes power easily accessible for future needs
Vertical Wire Manager
Rough-In Frame
Extra Hubcap
Accessories
8’-0”
4’-0” 4’-0”
WALL
Complete Raceway Shown with Top Covers, Transition Ramps, and End Ramps installed.
34”
FLEX
0-4
Dat
a C
able
s FLEX 0-4 Data C
ables
14 15
FLEX EXAMPLE RUN: 5-14 Data Cables
1
22
11
1
In-Wall Entrance Fitting(15’ pre-wired conduit)
4’ PowertracPower Hub
HubcapReceptacle Device (2-circuit 1, 2-circuit 2)
Data Device
A1.15
B.FX2.4B.HUB
C.HUBCAPC.PW1.12
C.DT2
$$$
$$$$$$
$$$$$$
$$$
QTY DESCRIPTIONFLEX CODE PRICE
FLEX 5-14 Data C
ables
Entrance FittingA
Raceway B
DevicesC
Flex 5-14 Data Cables
PowertracB.FX2.4
In-Wall Entrance Fitting
A1.15
PowertracB.FX2.4
Power HubB.HUB
Power HubB.HUB
Data DeviceC.DT2
HubcapC.HUBCAP
Receptacle DeviceC.PW1.12
Included with every raceway order:
Data Channel
End Ramps
Transition Ramps
Top Covers
In-Wall Entrance Fitting Surface-Mounted Entrance Fitting
Entrance FittingA
Wall Entrance Fitting
A1A2
A
Transition accessories included
Surface-Mounted Entrance FittingIn-Wall Entrance FittingA1.__
DESCRIPTIONDESCRIPTION FLEX CODEFLEX CODE
Use when cabling is running OUTSIDE the wall:Use when cabling is running INSIDE the wall:
A2.3A2.15A2.30
A1.15A1.30
3’ pre-wired conduit, 2’ Walltrac15’ pre-wired conduit, 12’ Walltrac30’ pre-wired conduit, 12’ Walltrac
15’ pre-wired conduit30’ pre-wired conduit
Base Trim included
TIP: Use A2.3 to connect to existing wall outlet boxes.
A2.__
Choose how your Flex raceways start at the wall.
16 17
*Powertrac measurements are based on the on-center distance between the Entrance Fitting and/or Power Hubs.
B.FX2.__
B.FX2.EXT
B.FX2.90
FLEX
5-1
4 D
ata
Cab
les
Top Covers, Data Channel & Ramps included
Datatrac Corner included
B.FX2.2B.FX2.3B.FX2.4B.FX2.5B.FX2.6
2’ Powertrac3’ Powertrac4’ Powertrac5’ Powertrac6’ Powertrac
HubcapPower Hub4’ Powertrac*4’ Powertrac* Power HubReceptacle DeviceCB
Power Hub Power Hub
FLEX 5-14 Data C
ablesPowertracs Power Hub
RacewayB
TIP: For greater flexibility at minimal cost, add more Power Hubs and connect shorter Powertracs.
Power HubB.HUB
DESCRIPTION DESCRIPTIONFLEX CODE FLEX CODE
Powertrac
Powertrac Extender
Powertrac Corner
Power Hub
Powertrac
Powertrac Extender
Powertrac Corner
Pre-wired raceway segmentsavailable in standard lengths:
Adds 6” to any of our standard Powertrac lengths
Allows raceway to make a 90° turn
C.HUBCAP
C.PW1.__
C.PW2.4
Power Devices
DevicesCChoose which devices (if any) you want to snap into your Power Hubs.
DESCRIPTIONFLEX CODE
Creates a walkable surface and makes power easily accessible for future needs
C.PW1.11C.PW1.22C.PW1.33C.PW1.44C.PW1.12*C.PW1.34*C.PW1.14*
All circuit 1All circuit 2All circuit 3All circuit 42-circuit 1, 2-circuit 22-circuit 3, 2-circuit 42-circuit 1, 2-circuit 4
Receptacle Device
Hardwire Device
Hubcap
Power devices are all interchangeable and can be hot-swapped
when desired.
Hubcap
Receptacle Device
Hardwire Device
Continue to build your raceways by connecting Powertracs and Power Hubs.
Connects Powertracs & provides access for power devices
Equip your Flex raceway system with power & data devices.
4-circuit monument that connects to most furniture base feeds
*Controlled devices available (see Technical Guide for more details)
Quad device available in various 4-circuit options:
18 19
Data DeviceC
8’-0”
4’-0” 4’-0”
WALL
38”
FLEX 5-14 Data C
ablesFLEX
5-1
4 D
ata
Cab
les
Data Devices
DevicesC
C.DT1
C.DT2
DESCRIPTIONFLEX CODE
Allows cables to enter/exit racewayGrommet
Data Device
Data DeviceGrommet
Optional Accessories Enhance your raceways with these additional options.
Extra HubcapVertical Wire Manager Rough-In Frame
VWM
RIF
C.HUBCAP
DESCRIPTIONFLEX CODE
Attaches to any power or data device to manage cabling
Installed before drywall to provide a rough opening for cabling
Creates a walkable surface and makes power easily accessible for future needs
Vertical Wire Manager
Rough-In Frame
Extra Hubcap
Accessories
Complete Raceway Shown with Top Covers, Transition Ramps, and End Ramps installed.
Equip your Flex raceway system with power & data devices.
Fits up to 8 low-voltage keystone modules
These devices go anywhere on the raceway.
Data devices easily snap next to any
power device.
20 21
FLEX EXAMPLE RUN: 15-24 Data Cables
1
22
11
2
In-Wall Entrance Fitting(15’ pre-wired conduit)
4’ PowertracPower Hub
HubcapReceptacle Device (2-circuit 1, 2-circuit 2)
Data Device
A1.15
B.FX3.4B.HUB
C.HUBCAPC.PW1.12
C.DT2
$$$
$$$$$$
$$$$$$
$$$
QTY DESCRIPTIONFLEX CODE PRICE
Entrance FittingA
Raceway B
DevicesC
Flex 15-24 Data Cables
PowertracB.FX3.4
PowertracB.FX3.4
Power HubB.HUB
Power HubB.HUB
Data DeviceC.DT2
ReceptacleDevice
C.PW1.12
Included with every raceway order:
Data Channels
End Ramps
Transition Ramps
Top Covers
In-Wall Entrance Fitting
A1.15
HubcapC.HUBCAP
FLEX 15-24 Data C
ables
In-Wall Entrance Fitting Surface-Mounted Entrance Fitting
Entrance FittingA
Wall Entrance Fitting
A1A2
A
Transition accessories included
Surface-Mounted Entrance FittingIn-Wall Entrance FittingA1.__
DESCRIPTIONDESCRIPTION FLEX CODEFLEX CODE
Use when cabling is running OUTSIDE the wall:Use when cabling is running INSIDE the wall:
A2.3A2.15A2.30
A1.15A1.30
3’ pre-wired conduit, 2’ Walltrac15’ pre-wired conduit, 12’ Walltrac30’ pre-wired conduit, 12’ Walltrac
15’ pre-wired conduit30’ pre-wired conduit
Base Trim included
TIP: Use A2.3 to connect to existing wall outlet boxes.
A2.__
Choose how your Flex raceways start at the wall.
22 23
*Powertrac measurements are based on the on-center distance between the Entrance Fitting and/or Power Hubs.
B.FX3.__
B.FX3.EXT
B.FX3.90
FLEX
15-
24 D
ata
Cab
les
Datatrac Corners included
B.FX3.2B.FX3.3B.FX3.4B.FX3.5B.FX3.6
2’ Powertrac3’ Powertrac4’ Powertrac5’ Powertrac6’ Powertrac
HubcapPower Hub4’ Powertrac*4’ Powertrac* Power Hub
Receptacle DeviceCB
Power Hub Power Hub
FLEX 15-24 Data C
ablesPowertracs Power Hub
RacewayB
TIP: For greater flexibility at minimal cost, add more Power Hubs and connect shorter Powertracs.
Power HubB.HUB
DESCRIPTION DESCRIPTIONFLEX CODE FLEX CODE
Powertrac
Powertrac Extender
Powertrac Corner
Power Hub
Powertrac
Powertrac Extender
Powertrac Corner
Pre-wired raceway segmentsavailable in standard lengths:
Adds 6” to any of our standard Powertrac lengths
Allows raceway to make a 90° turn
C.HUBCAP
C.PW1.__
C.PW2.4
Power Devices
DevicesCChoose which devices (if any) you want to snap into your Power Hubs.
DESCRIPTIONFLEX CODE
Creates a walkable surface and makes power easily accessible for future needs
C.PW1.11C.PW1.22C.PW1.33C.PW1.44C.PW1.12*C.PW1.34*C.PW1.14*
All circuit 1All circuit 2All circuit 3All circuit 42-circuit 1, 2-circuit 22-circuit 3, 2-circuit 42-circuit 1, 2-circuit 4
Receptacle Device
Hardwire Device
Hubcap
Power devices are all interchangeable and can be hot-swapped
when desired.
Hubcap
Receptacle Device
Hardwire Device
Top Covers, Data Channels & Ramps included
Continue to build your raceways by connecting Powertracs and Power Hubs.
Connects Powertracs & provides access for power devices
Equip your Flex raceway system with power & data devices.
4-circuit monument that connects to most furniture base feeds
*Controlled devices available (see Technical Guide for more details)
Quad device available in various 4-circuit options:
24 25
Data DevicesC
8’-0”
4’-0” 4’-0”
WALL
42”
FLEX 15-24 Data C
ablesFLEX
15-
24 D
ata
Cab
les
Data Devices
DevicesC
C.DT1
C.DT2
DESCRIPTIONFLEX CODE
Allows cables to enter/exit racewayGrommet
Data Device
Data DeviceGrommet
Optional Accessories Enhance your raceways with these additional options.
Extra HubcapVertical Wire Manager Rough-In Frame
VWM
RIF
C.HUBCAP
DESCRIPTIONFLEX CODE
Attaches to any power or data device to manage cabling
Installed before drywall to provide a rough opening for cabling
Creates a walkable surface and makes power easily accessible for future needs
Vertical Wire Manager
Rough-In Frame
Extra Hubcap
Accessories
Complete Raceway Shown with Top Covers, Transition Ramps, and End Ramps installed.
Equip your Flex raceway system with power & data devices.
Fits up to 8 low-voltage keystone modules
These devices go anywhere on the raceway.
Data devices easily snap next to any
power device.
26 27