Post on 17-Mar-2020
©
5201 S. Broadway Avenue,
Suite 200
Tyler, Texas 75703
903.592.0728
903.595.0369 fax
info@fitzpatrickarchitects.com
11/01/17
JOB NUMBER
SHEET NUMBER
16.106
DATE
E
D
C
B
A
1 2 3 4 5 6
SO
UT
HS
ID
E B
AN
K
SO
UT
H B
RO
AD
WA
Y B
RA
NC
H
TY
LE
R, T
X
SHEET REVISION HISTORY
PROJECT MANAGER
EDDIE LACROIX
IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1")
EXACTLY, THIS DRAWING HAS BEEN ENLARGED OR REDUCED,
AFFECTING ALL LABELED SCALES.
ROGER H. BARNES, P.E.
107023
THESE DRAWINGS DO NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY.
17-023
ENGINEER:
LICENSE NO.
CONSULTING ENGINEERS
FIRM REGISTRATION NO. 667
3003 KNIGHT STREET, SUITE 120
SHREVEPORT, LOUISIANA 71105
phone: 318-425-7452 fax: 318-425-4622
www.AFJMc.com
COPYRIGHT NOTICE:
THIS ENGINEERING DRAWING SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH AFJMC. NO
OTHER USE DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF AFJMC.
ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
MECHANICAL
GENERAL NOTES
M101
PLUMBING LEGENDSYMBOL DESCRIPTION
DOMESTIC COLD WATER (CW)
DOMESTIC HOT WATER (HW)
DOMESTIC HOT WATER RETURN (HWR)
SANITARY SEWER OR WASTE (SS OR W)
SANITARY VENT (V)
CLEANOUT (CO)
DOUBLE CLEANOUT (DCO)
WALL CLEANOUT (WCO)
BALL VALVE
SHUT-OFF VALVE (SOV)
BACKFLOW PREVENTER
FINISH FLOOR CLEANOUT
VENT THRU ROOF
UNDER COUNTER
UNDER GROUND
UNDER SLAB
ABOVE FINISHED FLOOR
CONDENSATE DRAIN PIPINGC
VALVE IN BOX
VALVE IN VERTICAL
BFP
FFCO
VTR
U/C
U/G
U/S
AFF
WALL FAUCET (WF)
MECHANICAL LEGENDSYMBOL DESCRIPTION
SUPPLY AIR DIFFUSER OR DUCT
RETURN AIR GRILLE, REGISTER OR DUCT
EXHAUST AIR GRILLE, REGISTER OR DUCT
EXHAUST FAN
SUPPLY AIR
RETURN AIR
EXHAUST AIR
OUTSIDE AIR
ABOVE FINISHED FLOOR
DOUBLE WALL INSULATED DUCT (PERF LINER)
DUCT ELBOW WITH TURNING VANES
MANUAL VOLUME DAMPER
THERMOSTAT/TEMPERATURE SENSOR
DUCT TRANSITION
PLUMBING GENERAL NOTESMECHANICAL GENERAL NOTESCONTRACTOR SHALL PROVIDE COMPLETE AND WORKABLE HVAC SYSTEMS IN ACCORDANCE
WITH BUT NOT LIMITED TO THE PLANS AND SPECIFICATIONS. COMPLY WITH LATEST EDITIONS
OF ALL APPLICABLE CODES INCLUDING NFPA 101:9.2, 90A AND 90B. OBTAIN ALL PERMITS AND
PAY ALL REQUIRED FEES.
REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF GRILLES
AND DIFFUSERS IN CEILINGS AND WALLS.
FIRE DAMPERS WHERE REQUIRED SHALL BE DYNAMIC TYPE. PROVIDE ACCESS DOORS AS
REQUIRED. REFER TO ARCHITECTURAL PLANS FOR LOCATIONS OF ALL RATED WALLS.
DUCT SIZES TO DIFFUSERS, GRILLES AND REGISTERS SHALL BE SAME SIZE AS INLET/NECK
SIZE. BRANCH HIGH PERFORMANCE TAKEOFFS SHALL BE SAME SIZE AS DIFFUSER NECKS
UNLESS OTHERWISE NOTED.
PROVIDE ACCESS DOORS AT GYPSUM BOARD CEILINGS AND INACCESSIBLE WALLS FOR
DAMPERS, VALVES, CONTROLS, ELECTRICAL, ETC. ACCESS. COORDINATE LOCATIONS &
SUBMIT TO ARCHITECT FOR REVIEW BEFORE INSTALLATION.
SECURE DIFFUSERS AND GRILLES TO T-BAR OR CEILINGS. SUBMIT SHOP DRAWINGS FOR
APPROVAL PRIOR TO STARTING WORK.
INSULATED PIPING AND FITTINGS EXPOSED TO VIEW, THROUGHOUT THE FACILITY, SHALL BE
COVERED & FINISHED WITH PVC JACKET EQUAL TO MANVILLE CEEL-CO PIPE JACKETING
SYSTEM USING 30 MIL THICK JACKET. FITTINGS, FLANGES, VALVES & ACCESSORIES SHALL BE
JACKETED. INSTALL PER MANUFACTURER'S INSTRUCTIONS WITH SEAM ON TOP OF PIPE SO AS
NOT TO BE VISIBLE FROM OCCUPIED SPACE. FINISH PAINT, VERIFY COLOR WITH ARCHITECT.
DUCTWORK SHALL BE SUPPORTED IN ACCORDANCE WITH APPLICABLE STANDARDS SET
FORTH IN THE INTERNATIONAL MECHANICAL CODE.
DUCTWORK SHALL BE SEISMICALLY BRACED IN ACCORDANCE WITH SMACNA GUIDELINES FOR
SEISMIC RESTRAINT.
WHERE MECHANICAL EQUIPMENT IS LOCATED IN ELECTRICAL ROOMS, COORDINATE EXACT
LOCATION WITH ELECTRICAL SHOP DRAWINGS PRIOR TO MOUNTING OR HANGING
MECHANICAL EQUIPMENT OR ROUTING PIPING. NO EQUIPMENT OR PIPING SHALL BE LOCATED
OR ROUTED ABOVE ELECTRICAL GEAR.
DUCT SYSTEMS FABRICATION AND INSTALLATION SHALL CONFORM IN ALL RESPECTS WITH
THE INTERNATIONAL MECHANICAL CODE. DUCT INSULATION (WRAP & LINER, AS INDICATED)
MATERIALS AND INSTALLATION SHALL COMPLY WITH THE INTERNATIONAL MECHANICAL CODE.
PROVIDE FLEXIBLE CONNECTIONS AT ALL SUPPLY AND RETURN CONNECTIONS ON A/C UNITS
AND AT ALL EXHAUST FANS.
SUPPLY AIR DUCT FOR A MINIMUM OF FIRST 10 FEET AT AIR HANDLER DISCHARGE, ALL
EXPOSED SUPPLY AIR DUCTS, AND ALL RETURN DUCTS SHALL BE INSULATED DOUBLE WALL
CONSTRUCTION WITH PERFORATED INTERIOR LINING. REMAINDER OF ALL DUCT SYSTEMS
(R/A, E/A AND S/A) SHALL BE EXTERNALLY WRAPPED WITH STANDARD DUCT INSULATION.
FLEXIBLE DUCT SHALL BE R8 MINIMUM AND SHALL EXTEND FROM DIFFUSER NOT MORE THAN
5'-0" OR AS DIRECTED BY LOCAL BUILDING INSPECTOR, FREE OF KINKS AND SAME SIZE AS
DIFFUSER NECK.
ALL DUCT DIMENSIONS SHOWN ARE INSIDE CLEAR.
UNDER NORMAL ANTICIPATED OPERATING CONDITIONS (WITH DOORS CLOSED, AS
APPLICABLE), ROOM RETURN AIRFLOWS SHALL BE EQUAL TO ROOM SUPPLY AIRFLOWS,
UNLESS NOTED OTHERWISE.
PROVIDE DUCT-MOUNTED SMOKE DETECTOR IN SUPPLY AND RETURN DUCT OF ALL AIR
HANDLING DEVICES OF FIVE TON NOMINAL SIZE AND ABOVE, OR 2000 CFM AND OVER, OR
SERVING A MEANS OF EGRESS. UPON ACTIVATION OF SMOKE DETECTOR, FAN MOTOR SHALL
SHUT DOWN, AUDIO/VISUAL ALARM SHALL BE INITIATED IN A NORMALLY OCCUPIED SPACE.
PROVIDE REMOTE-MOUNTED ALARM TEST STATION. INSTALLATION SHALL BE IN ACCORDANCE
WITH NFPA 90A, INTERNATIONAL MECHANICAL CODE AND THE AUTHORITY HAVING
JURISDICTION. AS APPLICABLE, COORDINATE COMPONENT PROVISIONS AND INSTALLATION
WITH FIRE ALARM SUPPLIER AND SUBCONTRACTOR.
PROVIDE FIRE-STAT IN RETURN DUCT OF AIR HANDLING DEVICES UNDER 2000 CFM. UPON
ACTIVATION OF FIRE-STAT, FAN MOTOR SHALL SHUT DOWN. INSTALLATION SHALL BE IN
ACCORDANCE WITH INTERNATIONAL MECHANICAL CODE AND THE AUTHORITY HAVING
JURISDICTION.
CONTRACTOR SHALL FIELD VERIFY LOCATION OF ROOF MOUNTED OR ATTIC MOUNTED
EQUIPMENT TO AVOID CUTTING ANY EXISTING STRUCTURAL MEMBERS. JOIST SHALL NOT BE
CUT WITHOUT THE WRITTEN APPROVAL OF THE ENGINEER.
VERIFY FINAL LOCATION OF THERMOSTAT OR OTHER TEMPERATURE CONTROL DEVICE WITH
OWNER/ARCHITECT PRIOR TO INSTALLATION. PROVIDE CLEAR LOCKING COVERS. WHERE
UNABLE TO BE CONCEALED WITHIN OR BY THE BUILDING CONSTRUCTION, ANY ASSOCIATED
EXPOSED, LOW VOLTAGE CONTROL WIRING WITHIN THE BUILDING INTERIOR SHALL BE
INSTALLED WITHIN CONDUIT AND PAINTED TO MATCH INTERIOR FINISHES.
EQUIPMENT DIMENSIONS ARE BASED ON PRODUCTS SCHEDULED. REFER TO SPECIFICATIONS
FOR ACCEPTABLE MANUFACTURERS AND REQUIREMENTS.
FOR INTERIOR, PROVIDE INSULATED FULL SIZE (OR SIZE AS NOTED) COPPER CONDENSATE
DRAIN FROM ALL COOLING COILS TO TERMINATION AS NOTED. TERMINATE OPEN SITE. FOR
EXTERIOR (ROOF), PROVIDE FULL SIZE (OR SIZE AS NOTED) "PAINTED" SCHEDULE 80 PVC
CONDENSATE DRAIN FROM ALL HVAC UNIT CONDENSATE CONNECTIONS; EXTEND AND
TERMINATE AT ROOF DRAIN OR AS NOTED.
COORDINATE INSTALLATION OF EQUIPMENT, DUCTS AND PIPING WITH OTHER TRADES. INFORM
ARCHITECT/ENGINEER OF INTERFERENCES.
VERIFY ALL OUTSIDE AIR INTAKE AND EXHAUST LOCATIONS WITH ARCHITECT. VERIFY STYLE
AND COLOR OF ALL OUTSIDE AIR INTAKE AND EXHAUST LOUVERS WITH ARCHITECT. PAINT TO
MATCH FINAL ADJACENT BUILDING FINISH UNLESS DIRECTED OTHERWISE. OUTSIDE AIR
INTAKES SHALL BE LOCATED A MINIMUM OF 10'-0" FROM ANY EXHAUST OR VTR. INTAKES
SHALL REMAIN CLOSED UNTIL AIR BALANCING PHASE.
EQUIPMENT START-UP SHALL BE BY MANUFACTURER'S AUTHORIZED REPRESENTATIVES.
CONTRACTOR SHALL INSTALL NEW FILTERS (MERV 8, MINIMUM) IN ALL AIR HANDLERS AFTER
COMPLETION OF ALL CONSTRUCTION AND FINAL TEST AND BALANCE AND PRIOR TO OWNER
OCCUPANCY. PROVIDE A MINIMUM OF 2 SETS OF SPARES FOR EACH UNIT.
EQUIPMENT, CONTROLS AND REFRIGERANT LINES SHALL BE INSTALLED IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS.
WHERE VISIBLE TO PUBLIC VIEW, PRIME/PAINT ALL ASSOCIATED EXPOSED MECHANICALSYSTEM COMPONENTS TO MATCH ADJACENT FINISHES, UNLESS DIRECTED OTHERWISE BYARCHITECT. ALL ASSOCIATED FIELD PAINTING UNLESS DIRECTED OTHERWISE SHALL BE BY APAINTING CONTRACTOR; COORDINATE IN ADVANCE AS REQUIRED.
PRIOR TO ORDER, CONTRACTOR SHALL COORDINATE AND VERIFY ALL EXACT EQUIPMENT
POWER PROVISIONS AND REQUIREMENTS WITH CORRESPONDING ELECTRICAL PLANS.
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASSOCIATED CONTROL WIRING AND THE
COORDINATION OF ALL SUPPLY POWER.
WHERE WATER PRESSURE WITHIN A BUILDING EXCEEDS 80 PSI STATIC, AN APPROVED
WATER-PRESSURE REDUCING VALVE WITH STRAINER SHALL BE INSTALLED TO REDUCE THE
PRESSURE IN THE BUILDING WATER DISTRIBUTION PIPING TO NOT GREATER THAN 80 PSI
STATIC.
CONTRACTOR TO PROVIDE A COMPLETE AND WORKABLE PLUMBING SYSTEM IN ACCORDANCE
WITH BUT NOT LIMITED TO THE PLANS AND SPECIFICATIONS. COMPLY WITH LATEST EDITIONS
OF ALL APPLICABLE CODES. OBTAIN ALL PERMITS AND PAY ALL REQUIRED FEES.
CONTRACTOR SHALL COORDINATE LOCATION OF UTILITY MAINS WITH CIVIL SITE PLAN FOR
EXACT ROUTING OF BUILDING SERVICE LINES PRIOR TO BIDDING. UTILITY SERVICE REVISIONS
REQUIRED DURING CONSTRUCTION SHALL BE COMPLETED AT NO EXTRA COST TO OWNER.
V.T.R.'S SHALL BE MIN 10'-0" FROM O/A INTAKES. OFFSET VENT AS REQUIRED. COMBINE VENTS
WHERE POSSIBLE TO MINIMIZE ROOF PENETRATIONS. VERIFY LOCATIONS OF ROOF
PENETRATIONS WITH ARCHITECT PRIOR TO ROUGH-IN.
PROVIDE CHROME PLATED ESCUTCHEONS AT PIPE SLEEVES FOR EXPOSED BARE PIPE.
PROVIDE ACCESS OPENINGS IN GYPSUM BOARD CEILINGS AND INACCESSIBLE WALLS FOR
VALVES AND DAMPERS. PROVIDE HINGED, LOCKABLE ACCESS PANEL COVER IN MILL FINISH;
COORDINATE EXACT LOCATION AND FINAL PAINT FIELD-APPLIED PAINT FINISH PRIOR TO
ROUGH-IN AND INSTALLATION.
INSULATE TAILPIECE, TRAP AND WATER SUPPLIES AT HANDICAPPED FIXTURES. USE TRUEBRO
LAV-GUARD FACTORY FABRICATED INSULATING BOOTS OR APPROVED EQUAL.
PLUMBING FIXTURES SHALL COMPLY WITH ALL APPLICABLE NATIONAL, STATE AND LOCAL
CONSERVATION STANDARDS.
EQUIPMENT START-UP SHALL BE BY MANUFACTURER'S AUTHORIZED REPRESENTATIVES.
PLUMBING RISER ISOLATION & DRAIN VALVES SHALL BE LOCATED WITHIN EASY REACH OF
CEILING, WHERE CEILINGS OCCUR BELOW OR DROPPED TO WITHIN A MAXIMUM 10'-0" OF
FINISHED FLOOR WHERE NO CEILING OCCURS.
PIPING SHALL BE SEISMICALLY BRACED IN ACCORDANCE WITH SMACNA GUIDELINES FOR
SEISMIC RESTRAINT.
INSULATED PIPING AND FITTINGS EXPOSED TO VIEW THROUGHOUT THE FACILITY SHALL BE
COVERED AND FINISHED WITH PVC JACKET EQUAL TO MANVILLE CEEL-CO 550 PIPE JACKETING
SYSTEM USING 30 MIL THICK JACKET AND FITTING COVERS. INSTALL PER MANUFACTURER'S
INSTRUCTIONS WITH SEAM ON TOP OF PIPE SO AS TO BE NOT VISIBLE FROM OCCUPIED
SPACE.
PROVIDE WALL CLEANOUTS AT FIXTURES IN ACCORDANCE WITH APPLICABLE SECTIONS OF
INTERNATIONAL PLUMBING CODE.
PROVIDE
1
2
" SHUTOFF VALVE AHEAD OF EACH TRAP PRIMER. PROVIDE ACCESS OPENING &
DISTRIBUTION DEVICE WHERE NEEDED.
PROVIDE
3
4
" SHUTOFF VALVE AHEAD OF EACH WALL FAUCET INSTALLATION. PROVIDE ACCESS
OPENINGS WHERE NEEDED.
COORDINATE EXACT PLUMBING FIXTURE TYPE AND MOUNTING HEIGHT WITH OWNER &
ARCHITECT PRIOR TO ORDER, ROUGH-IN AND INSTALLATION.
COORDINATE EXACT PIPE AND RISER ROUTING WITH STRUCTURAL AND ELECTRICAL TRADES.
NOTIFY ENGINEER OF ANY DISCREPANCIES.
WATER AND VENT PIPING SHALL BE RUN AS HIGH AS POSSIBLE (THROUGH JOISTS AS
NECESSARY) TO PROVIDE CLEARANCE FOR OTHER EQUIPMENT AND TRADES. ALL PIPING TO
BE CONCEALED ABOVE CEILING UNLESS OTHERWISE NOTED.
PROVIDE BLOCKING IN WALLS TO SECURE ALL WATER SUPPLY PIPING.
PIPING SHALL NOT BE INSTALLED ABOVE OR WITHIN 3'-0" IN FRONT OF ELECTRICAL SERVICE
PANELS. COORDINATE ROUTING WITH ELECTRICAL CONTRACTOR.
INSTALL WATER CLOSET FLUSH VALVES WITH OPERATING HANDLE ON THE WIDE SIDE OF THE
TOILET STALL, PER TAS REQUIREMENTS.
PROVIDE CONCEALED FIXTURE CARRIERS FOR ALL WALL MOUNTED PLUMBING FIXTURES.
UNLESS NOTED OTHERWISE, INSTALL FLOOR DRAINS FLUSH WITH FINISHED FLOOR AND NOT
SLOPED TO DRAIN; COORDINATE WITH ARCHITECTURAL AND FOUNDATION PLANS
ACCORDINGLY.
PIPE PENETRATIONS THROUGH FIRE/SMOKE WALLS AND PARTITIONS SHALL BE FIRE-CAULKED.
TEST ENTIRE SYSTEM FOR LEAKS AS REQUIRED BY THE LOCAL AUTHORITY HAVING
JURISDICTION.
STERILIZE WATER SYSTEM WITH CHLORINE SOLUTION AS REQUIRED BY THE LOCAL
AUTHORITY HAVING JURISDICTION.
PROVIDE DOMESTIC WATER SERVICE BACKFLOW PREVENTER AS REQUIRED BY LOCAL
AUTHORITY HAVING JURISDICTION. COORDINATE WITH SITE UTILITIES CONTRACTOR AND CIVIL
SITE UTILITY PLANS.
WHERE VISIBLE TO PUBLIC VIEW, PRIME/PAINT ALL ASSOCIATED EXPOSED PLUMBING SYSTEM
COMPONENTS TO MATCH ADJACENT FINISHES, UNLESS DIRECTED OTHERWISE BY ARCHITECT.
ALL ASSOCIATED FIELD PAINTING UNLESS DIRECTED OTHERWISE SHALL BE BY A PAINTING
CONTRACTOR; COORDINATE IN ADVANCE AS REQUIRED.
FOR INTERIOR, PROVIDE INSULATED FULL SIZE (OR SIZE AS NOTED) COPPER CONDENSATE
DRAIN FROM ALL COOLING COILS TO TERMINATION AS NOTED. TERMINATE OPEN SITE. FOR
EXTERIOR (ROOF), PROVIDE FULL SIZE (OR SIZE AS NOTED) "PAINTED" SCHEDULE 80 PVC
CONDENSATE DRAIN FROM ALL HVAC UNIT CONDENSATE CONNECTIONS; EXTEND AND
TERMINATE AT ROOF DRAIN OR AS NOTED.
,
,
M MOTORIZED VOLUME DAMPER
EF
S/A
R/A
E/A
O/A
AFF
CONDENSATE DRAIN PIPINGC
ROOFTOP UNITRTU
CONDENSING UNITCU
FAN COIL UNITFCU
FLOOR DRAINFD
REDUCED PRESSURE ZONERPZ
A-AIR DEVICE, B-NECK SIZE, C-AIRFLOW
DUCT SMOKE DETECTOR
A B
C
T
TRAP PRIMERTP
TRAP GUARD INSERTTG
OPPOSED BLADE DAMPEROBD
PLUMBING FIXTURE AND ROUGH-IN SCHEDULEMARK MANUF MODEL DESCRIPTION ACCESSORIES TRIM OR VALVE DRAIN TRAP SUPPLIES HW CW WASTE VENT
WC KOHLERK-96053WELLCOMMEULTRA
FLOOR MOUNTED WATER CLOSET,FLOOR OUTLET, SIPHON JET,ELONGATED VITREOUS CHINA BOWLAND BOLT CAPS, 1.28 GPF
CHURCH 9500CTWHITE PLASTIC OPENFRONT SEAT
SLOAN ROYAL MODEL 111-1.28 FLUSHVALVE - INTEGRAL - - 1 4 3
WCH KOHLERK-96057HIGHCLIFFULTRA
FLOOR MOUNTED WATER CLOSET,FLOOR OUTLET, SIPHON JET,ELONGATED VITREOUS CHINA BOWLAND BOLT CAPS, 1.28 GPF, (TASCOMPLIANT)
CHURCH 9500CTWHITE PLASTIC OPENFRONT SEAT
SLOAN ROYAL MODEL 111 -1.28 FLUSHVALVE - INTEGRAL - - 1 4 3
URH KOHLER K-4991-ETBARDON
WALL HUNG URINAL, BACK OUTLET, 3/4"TOP SPUD, ELONGATED RIM, VITREOUSCHINA WASHOUT ACTION, 0.5 GPF (TASCOMPLIANT)
- SLOAN REGAL 186-0.5 FLUSH VALVE - INTEGRAL - - 3/4 2 2
LH KOHLER K-2214 LADENA
UNDERMOUNT VITREOUS CHINALAVATORY (TAS COMPLIANT)
BELOW DECK
THERMOSTATIC
MIXING VALVE SLOAN
MIX-135-A
KOHLER K-7514 ELECTRONIC FAUCET, 5"MINIMUM SPOUT REACH; VIBRANTSTAINLESS FINISH
McGUIRE155A McGUIRE 8902 McGUIRE
2165LK 1/2 1/2 1 1/2 1 1/4
S1 ELKAY ELUH281610
30-1/2"x18-1/2"x10" DEEP SS SINGLEBOWL UNDERMOUNT SINK, 18 GAUGE,TYPE 302, COATED UNDERSIDE, SINGLEHOLE DRILLING (TAS COMPLIANT)
-
SYMMONS S-2302-PD-STS SERENO
KITCHEN FAUCET S-2302-PD, STAINLESS
STEEL FINISH, 15-7/8" TALL GOOSENECK,
8" SPOUT REACH, PULL-DOWN
HANDSPRAY WITH RETRACTABLE HOSE
McGUIRE151A McGUIRE 8912 McGUIRE
2165LK 1/2 1/2 1 1/2 1 1/4
SS FIAT MSB2424 24" x 24" x 10" MOLDED STONE MOPBASIN
832-AA HOSE, 889-CCHOLDER, MSG2424WALL GUARD
830-AA FAUCET INTEGRAL CAST IRONDEEP SEAL - 1/2 1/2 3 2
EWCH ELKAY ERPBM28K
STAINLESS STEEL TOP, BI-LEVELELECTRIC WATER COOLER, PUSHBUTTON CONTROL, CANE DETECTIONAPRON (TAS COMPLIANT)
MOUNTING BRACKET,MOUNT AS INDICATEDBY ARCH DWG
- INTEGRALGRID McGUIRE 8902 McGUIRE
ST12LK - 1/2 1 1/2 1 1/4
FD WADE 1100-A-1
CAST IRON BODY FLOOR DRAIN, SATINNICKEL BRONZE STRAINER ROUNDADJUSTABLE TOP, TRAP PRIMERTAPPING
- - - CAST IRONDEEP SEAL - - 1/2 3 2
TP PPP, INC. PRIME RITE TRAP PRIMER VALVE
DISTRIBUTION UNIT ASAPPLICABLE FORMULTIPLE FLOORDRAINS
- - - - - 1/2 - -
WH BRADFORD-WHITE LD-30L3-3 30 GALLON, 4.5 kW, "LOWBOY", THREE
YEAR TANK WARRANTY (MINIMUM)HOLDRITEQUICKSTAND/WALLMOUNT
- - - - 3/4 3/4 - -
DSP INSINK-ERATOR
EVOLUTIONCOMPACT U/C DISPOSER, 1/2 HP DRAIN CONNECTOR
KIT - SIDE INLETFITTING - - - - - -
IOB OATEY 39141 METAL ICE MAKER WATER SUPPLY BOX,1/4 TURN, LOW LEAD - - - - - - 1/2 - -
WF WOODFORD 65 FREEZE LESS WALL HYDRANT (24"AFG) - - - - - - 3/4 - -
MV LEONARD 170A-LF-BP-CPCHROME PLATED THERMOSTATICPOINT-OF-USE MIXING VALVE WITH COLDWATER BYPASS
- - - - - 1/2 1/2 - -
RD WADE 3000AE-42 CAST IRON BODY ROOF DRAIN,ADJUSTABLE, CAST IRON DOME - - - - - - - - -
SRD WADE 3000AE-42DCAST IRON BODY ROOF DRAIN,ADJUSTABLE, CAST IRON DOME, 2"EXTERNAL DAM
- - - - - - - - -
DSN WADE 3941-85
TYPE 304 FABRICATED STAINLESS STEELDOWNSPOUT COVER, SECURINGFLANGE, HINGED SLOTTED GRATE, SATINFINISH
- - - - - - - - -
REFERENCE PLUMBING FIXTURE SPECIFICATION FOR ADDITIONAL ALTERNATE MANUFACTURERS.*VERIFY EXACT FIXTURE TYPE, FINISH, MOUNTING HEIGHT, ETC. WITH ARCHITECT PRIOR TO ORDER AND INSTALLATION.**CONTRACTOR SHALL VERIFY ALL POWER REQUIREMENTS WITH ELECTRICAL PLANS PRIOR TO ORDER AND INSTALLATION.
PIPE SCHEDULEWASTE / VENT / STORM SCHEDULE 40 PVC
WATER HARD COPPER TYPE "L"CONDENSATE (INTERIOR) HARD COPPER TYPE "M"CONDENSATE (EXTERIOR) SCHEDULE 80 PVC (PAINTED)
REFERENCE SPECIFICATIONS FOR FITTINGS, HANGERS, JOINING METHODSAND INSULATION/PAINTING REQUIREMENTS.
EXHAUST FAN SCHEDULEMARK GREENHECK
MODELVOLUME
(CFM) ESP (") RPM OPERATINGPOWER SONES NOTES
EF-1,2 SP-B150 150 0.4 1050 128 W 3.5 A-D
EF-3 SP-B110 75 0.4 950 80 W 1.3 A-C,E
ALTERNATE ACCEPTABLE MANUFACTURERS: COOK, TWIN CITY OR APPROVED EQUAL.*CONTRACTOR SHALL VERIFY ALL POWER REQUIREMENTS WITH ELECTRICAL PLANS PRIORTO ORDER AND INSTALLATION.
NOTES:A. EXTEND AND CONNECT E/A DUCT TO ROOF-MOUNTED EXHAUST HOOD ASINDICATED/NOTED.B. PROVIDE SOLID STATE SPEED CONTROLLER, CONCEALED/FAN-MOUNTED, FOR AIRFLOWADJUSTMENT.C. PROVIDE FACTORY ALUMINUM GRILLE AND INTEGRAL BACKDRAFT DAMPER.D. INTERLOCK WITH ROOM LIGHT SWITCH.E. CONFIGURE FOR CONTINUOUS OPERATION.
AIR DISTRIBUTION DEVICE SCHEDULEMARK DESCRIPTION MOUNTING MANUFACTURER'S
CATALOG NO. MATERIAL FINISH ACCESSORIES / REMARKS
D1 CEILING SUPPLYDIFFUSER LAY-IN PRICE ASPD ALUM WHITE BAKED
ENAMEL24x24 SQUARE PLAQUE DIFFUSER, 4-WAY
THROW, NECK SIZE AS INDICATED
D2 CEILING SUPPLYDIFFUSER SURFACE PRICE ASPD ALUM WHITE BAKED
ENAMEL12x12 SQUARE PLAQUE DIFFUSER, 4-WAY
THROW, NECK SIZE AS INDICATED
D3
CEILING SUPPLY
DIFFUSER
LAY-IN /TECHZONE
CEILING
PRICE
SDS75/SDB75
ALUM WHITE BAKEDENAMEL
TYPE 18, 9/16" TEGULAR SLOT DIFFUSER,
(2) 3/4" SLOTS, 6" WIDE, 4 FT LONG,
INSULATED PLENUM BOX, TECHZONE
CEILING COMPATIBLE
D4
LINEAR SLOTSUPPLY DIFFUSER SURFACE PRICE
SDS100/SDBI100 ALUM
PRIME/PAINT;FINISH AS
DIRECTED BYARCHITECT
SLOT DIFFUSER WITH (2) 1" WIDE SLOTS, 5 FTLONG, CONCEALED PLASTER FRAMEMOUNTING CONFIGURATION, FIELD
FABRICATE INSULATED PLENUM BOX
D5
DUCT MOUNTEDSUPPLY DIFFUSER
EXPOSEDDUCT PRICE SDGE ALUM
PRIME/PAINT;FINISH AS
DIRECTED BYARCHITECT
14x6 SPIRAL DUCT REGISTER, 3/4" BLADESPACING, 45 DEFLECTION, LONG BLADES IN
FRONT, WITH AIR SCOOP (AS)
D6
SIDEWALL SUPPLYDIFFUSER
DUCT /SURFACE PRICE 610D ALUM WHITE BAKED
ENAMELLOUVERED FACE SINGLE DEFLECTION
GRILLE, LONG BLADES IN FRONT, OBD, 8/4
G1 CEILING RETURNGRILLE LAY-IN PRICE 80D ALUM WHITE BAKED
ENAMEL1/2 x 1/2 x 1/2 GRID EGG CRATE CORE,
24/24 PANEL SIZE, OBD
G2 CEILING RETURNGRILLE SURFACE PRICE 80D ALUM WHITE BAKED
ENAMEL1/2 x 1/2 x 1/2 GRID EGG CRATE CORE,
12/12 PANEL SIZE, OBD
G3 CEILING RETURNGRILLE
LAY-IN /TECHZONE
CEILINGPRICE 80 ALUM WHITE BAKED
ENAMEL
1/2 x 1/2 x 1/2 GRID EGG CRATE CORE,24/6 PANEL SIZE, TECHZONE CEILING
COMPATIBLE
VERIFY EXACT DEVICE TYPE/FINISH WITH ALL CEILING PER ARCHITECTURAL PLANS PRIOR TO ORDER AND INSTALLATION. ALTERNATE ACCEPTABLEMANUFACTURERS: TUTTLE & BAILEY, TITUS, KRUEGER, METALAIRE OR APPROVED EQUAL. OPPOSED BLADE DAMPERS AS SCHEDULED SHALL BEOMITTED FOR TRANSFER AIR DUCT APPLICATIONS ONLY.
DUCTLESS SPLIT SYSTEM SCHEDULEMARK
(FCU/CU)AIR HANDLING UNIT
(DAIKIN)CONDENSINGUNIT (DAIKIN)
S/A (CFM)[WET] SEER REFRIGERANT CAPACITY
(BTUH)
A FTK24NMVJU RK24NMVJU 713 / 579 / 512 / 403 18.0 R410A 21200
*CONTRACTOR SHALL VERIFY ALL POWER REQUIREMENTS WITH ELECTRICAL PLANS PRIOR TO ORDER ANDINSTALLATION. ALTERNATE ACCEPTABLE MANUFACTURERS: MITSUBISHI, TRANE, LG OR AN APPROVED EQUAL.
A. "COOLING ONLY" UNIT CONFIGURATION. PROVIDE INDOOR UNIT WITH INTEGRAL CONDENSATE PUMP BY THEUNIT MANUFACTURER CONCEALED WITHIN THE UNIT CASING; A SEPARATE EXPOSED CONDENSATE PUMP SHALLNOT BE ACCEPTABLE, UNLESS PUMP ASSEMBLY IS SPECIFICALLY MADE FOR USE WITH A WALL-MOUNTED"DUCTLESS" FAN COIL UNIT.
"OCCUPIED" TIMES SHALL BE AS DEFINED BY SSB STAFF AND PROGRAMMED ACCORDINGLY FOR ALL
ROOFTOP UNITS, OTHER THAN FOR THE IT ROOM DUCTLESS SPLIT SYSTEM UNIT, FCU-A, WHICH SHALL RUN
CONTINUOUSLY. ALL OTHER TIMES SHALL BE CONSIDERED "UNOCCUPIED." DURING OCCUPIED PERIODS,
ALL UNITS SHALL BE SET (ADJUSTABLE) TO MAINTAIN 72°F AND 72°F IN COOLING AND HEATING MODE AND
FCU-A (COOLING-ONLY) SHALL BE SET (ADJUSTABLE) TO MAINTAIN 75°F IN COOLING MODE. DURING
UNOCCUPIED PERIODS, ALL HVAC EQUIPMENT SETPOINTS SHALL AUTOMATICALLY ALTER SETTINGS AND
SETBACK (ADJUSTABLE) TO MAINTAIN 85°F AND 55°F IN ACCORDANCE WITH THE ENERGY CODE. EXHAUST
FANS SHALL OPERATE AS SCHEDULED. ALL FINAL SPACE TEMPERATURE SETTING ADJUSTMENTS SHALL
OCCUR WITH THE BUILDING IN USE, FULLY OCCUPIED AND WITH ALL EQUIPMENT IN OPERATION AND ALL
ASSOCIATED CHANGES SHALL BE COORDINATED WITH AND APPROVED BY SSB STAFF.
HVAC SEQUENCE OF OPERATIONS
PACKAGED ROOFTOP UNIT WITH ELECTRIC HEAT
MARK NOMINALTONNAGE
MODEL NO.(LENNOX)
EVAPORATOR FAN COOLING
HEATING(kW) NOTES
CFM
HPESP
(IWG) RPM
TEMPERATURE (F) NET CAPACTIYSEER /IEERS/A O/A
ENT AIR LVG AIR ODAMB
TOTAL(MBH)
SENS(MBH)DB WB DB WB
RTU-1 10 LCH120H4B 4350 200 3.0 0.8 1200 77.1 64.0 57.2 55.1 100 111.0 89.9 - / 13.2 60A,B,C,D,E,F
RTU-2 6 LCH072H4B 2650 250 2.0 0.7 1100 77.4 64.3 56.5 55.1 100 69.5 57.2 - / 13.5 30 A,B,C,D,E,F
RTU-3 4 LCH048H4E 1550 75 0.8 0.5 1050 76.1 63.4 54.5 53.3 100 44.5 35.1 17.6 / - 15 A,C,D,F
*CONTRACTOR SHALL VERIFY ALL POWER REQUIREMENTS WITH ELECTRICAL PLANS PRIOR TO ORDER AND INSTALLATION. ALTERNATE ACCEPTABLE MANUFACTURERS:AAON, CARRIER, TRANE, YORK OR APPROVED EQUAL. OUTDOOR DESIGN CONDITIONS: 100 DB/ 77 WB (SUMMER), 25 WINTER.
A. FACTORY MOUNTED UNIT DISCONNECT SWITCH AND INTEGRAL FACTORY INSTALLED/FIELD WIRED (PROVIDED WITH SEPARATE CIRCUIT FEED IN LIEU OF UNITPOWER) 120 VOLT CONVENIENCE OUTLET, FULL PERIMETER INSULATED EQUIPMENT ROOF CURB (MATCH ROOFING SYSTEM PER ARCHITECTURAL), 2" FILTER FRAMEWITH MERV 8 FILTERS (INCLUDE (2)TWO SPARE SETS IN ADDITION TO INITIAL START-UP FILTER SET), 5-YEAR COMPRESSOR WARRANTY, ELECTRIC HEAT EXCHANGERWITH SCR CONTROL, LOW AMBIENT COOLING TO 0°F, INTEGRAL HAIL GUARDS. PROVIDE INTERNAL BI-POLAR IONIZATION PLASMA GENERATOR AIR PURIFICATION EQUAL
TO GLOBAL PLASMA SOLUTIONS MODEL FC (EXACT SERIES AS REQUIRED BY SUPPLY AIRFLOW) OR AN APPROVED EQUAL AS SPECIFIED; INTERLOCK/POWER FROM AIR
HANDLING UNIT. PROVIDE UNIT WITH FACTORY-MOUNTED BACNET CONTROLS INTERFACE MODULE AND PROVIDE UNIT WITH PROGRAMMABLE THERMOSTAT WITHDIGITAL DISPLAY AND CLEAR LOCKING COVER.B. PROVIDE EQUIPMENT ROOF CURB (MATCH ROOFING SYSTEM PER ARCHITECTURAL) AS NOTED WITH ISOLATION RAIL (1" MINIMUM DEFLECTION).C. PROVIDE UNIT WITH HINGED ACCESS PANELS.D. PROVIDE UNIT WITH 2 STAGES OF COOLING.E. PROVIDE UNIT WITH HUMIDITROL ACTIVE DEHUMIDIFICATION; SET TO MAINTAIN 55% RH (ADJUSTABLE).F. PROVIDE UNIT WITH AUTOMATIC MODULATING DUAL ENTHALPY ECONOMIZER WITH HOOD CONTROLLED BY DRY BULB TEMPERATURE SENSOR IN OUTSIDE AIR INTAKEOF UNIT AND BAROMETRIC RELIEF DAMPERS WITH HOOD.
CO
IN
MA
CH
CA
SH
SA
FE
DR
IV
E T
HR
U
BA
NK
ER
S
10
9
DR
IV
E T
HR
U
ST
OR
10
8
NIG
HT
DE
P
85
6
3
11
10
14
2
9
CO
RR
11
5
CO
RR
11
0
CO
RR
13
2
RE
SO
UR
CE
12
6
LO
BB
Y
10
1
BA
NK
ER
S
10
4
BA
NK
ER
S
10
3
VIE
WIN
G
10
6
ST
OR
AG
E
12
5
OF
FIC
E
11
1
OF
FIC
E
11
2
OF
FIC
E
11
3
OF
FIC
E
11
4
WO
ME
N
11
6
ME
N
11
7
BR
EA
K R
OO
M
12
0
RJ
O
FF
IC
E
13
1
RJ
O
FF
IC
E
12
9
RJ
R
ES
OU
RC
E
12
8
RJ
R
EC
EP
TIO
N
12
7
F
NIG
HT
D
RO
P
ST
OR
12
1
DE
AL
DR
WR
CA
SH
RE
C
UC
SN
IG
HT
DE
P
1
23
45
6
11
10
98
7
12
13
14
15
24
18
16
17
23
20
19
21
22
VA
UL
T
10
5
CO
NF
ER
EN
CE
12
2
ME
CH
/E
LE
C/IT
11
9
JA
NIT
OR
11
8
AD
MIN
10
7
VE
ST
IB
UL
E
10
0
T
T
EF-2EF-1
6"Ø
3
D5
_
275
TYP 2
7
1
22"Ø
24/22 S/A UP INTO
ATTIC CAVITY
10"Ø
6
RTU-1
D2 8
200
5
24/22
G1G1
T 1
26/22
D1 8
125
D2 6
50
D4 8
200
D1 10
400
TYP 2
D1 6
100
D1 6
100
D1 8
100
14/12
D2 6
50
D1 10
275
D1 8
175
D1 8
175
D1 8
150
12"Ø
D1 8
200
D1 10
225
D1 8
200
D2 6
50
D2 6
50
FD
FD
G1
G2
G2
G2
G2
G2
T
2
14/10
14/8
14/6
14/6
G2
CU-A
3
RTU-3
G2
G2
G1
14/6
D1 10
300
D1 10
300
D1 6
75 D3 8
175
D3 8
200
D3 8
150
10"Ø
14/12
RTU-2
26/22
14/8
26/10
26/14
12"Ø
18/12
22/1816/12
14/14
12/12
12"Ø
14/6
14/10
14/6
26/10
18/14
EF-3
22"Ø
26/22
8"Ø8"Ø
45'-8"
2'-11
1
2
"
10
'-5
"
14' AFF TO
TOP OF DUCT
C DUCT
L
8
FCU-A
D3 8
200
D3 8
150
9
G3
D5
_
300
TYP 2
D5
_
325
TYP 2
D5
_
400
TYP 2
G2
G3
D6
-
100
IN ATTIC CAVITY
D6
-
100
UP INTO ATTIC CAVITY
10"Ø
10"Ø
12"Ø
10"Ø
D4 8
200
TYP 3
4
TYP 3
2
D3 8
200
TYP 2
©
5201 S. Broadway Avenue,
Suite 200
Tyler, Texas 75703
903.592.0728
903.595.0369 fax
info@fitzpatrickarchitects.com
11/01/17
JOB NUMBER
SHEET NUMBER
16.106
DATE
E
D
C
B
A
1 2 3 4 5 6
SO
UT
HS
ID
E B
AN
K
SO
UT
H B
RO
AD
WA
Y B
RA
NC
H
TY
LE
R, T
X
SHEET REVISION HISTORY
PROJECT MANAGER
EDDIE LACROIX
IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1")
EXACTLY, THIS DRAWING HAS BEEN ENLARGED OR REDUCED,
AFFECTING ALL LABELED SCALES.
ROGER H. BARNES, P.E.
107023
THESE DRAWINGS DO NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY.
17-023
ENGINEER:
LICENSE NO.
CONSULTING ENGINEERS
FIRM REGISTRATION NO. 667
3003 KNIGHT STREET, SUITE 120
SHREVEPORT, LOUISIANA 71105
phone: 318-425-7452 fax: 318-425-4622
www.AFJMc.com
COPYRIGHT NOTICE:
THIS ENGINEERING DRAWING SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH AFJMC. NO
OTHER USE DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF AFJMC.
ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
HVAC PLANS
M201
1. ROUTE EXPOSED FLAT OVAL DUCT SYSTEM SECURE AND
HIGH AS PRACTICAL IN NEAT MANNER PERPENDICULAR OR
PARALLEL TO ADJACENT BUILDING SYSTEM COMPONENTS.
COORDINATE WITH ALL OTHER BUILDING SYSTEMS (I.E.
STRUCTURE, LIGHTING, ETC.) AS NEEDED PRIOR TO
ROUGH-IN AND INSTALLATION. INTERIOR EXPOSED
DUCTWORK SHALL BE PAINT-GRIP, DOUBLE WALL SPIRAL
ROUND. PAINT TO MATCH ADJACENT INTERIOR FINISH OR
AS DIRECTED BY ARCHITECT.
2. WALL MOUNTED FAN COIL UNIT; INSTALLED ABOVE TOP
OF ADJACENT DOOR FRAME LEVEL. EXTEND CONDENSATE
DRAIN TUBING FROM INTEGRAL PUMP OF DUCTLESS SPLIT
HVAC UNIT. ROUTE CONCEALED THROUGH WALL TO ABOVE
CEILING, THEN BACK CONCEALED DOWN IN WALL,
TURN/NINETY OUT ABOVE SERVICE SINK WALL GUARD AND
TERMINATE OPEN SITE INTO SERVICE SINK BELOW.
3. PROVIDE SPUN ALUMINUM DOMED EXHAUST HOOD
EQUAL TO GREENHECK GRSR-10 WITH INTEGRAL
BIRDSCREEN AND FLASHING FLANGE. PROVIDE FULL SIZE
INSULATED DUCT EXTENSION. EXTEND AND CONNECT EACH
EXHAUST BRANCH DUCT(S) AS INDICATED.
4. TRANSITION SUPPLY AND RETURN DUCT MAINS FULL SIZE
OF ROOFTOP UNIT DUCT CONNECTIONS AS APPLICABLE.
5. PENETRATE SUPPLY AIR BRANCH/DUCT THROUGH
CONCRETE VAULT CONSTRUCTION; COORDINATE ANY
ASSOCIATED OPENING/BLANK-OUT WITH VAULT PROVIDER
AS NEEDED PRIOR TO VAULT INSTALLATION, ROUGH-IN AND
CONSTRUCTION.
6. ROUTE SUPPLY DUCT MAIN THROUGH PITCHED ATTIC
ENCLOSURE. COORDINATE ALL ASSOCIATED
PENETRATIONS AS REQUIRED THROUGH DECK
CONSTRUCTION.
7. SEAL/FLASH EXPOSED CEILING DUCT PENETRATION;
PAINT TO MATCH EXPOSED DUCT/CEILING FINISH.
COORDINATE IN ADVANCE WITH ARCHITECTURAL PLANS
AND ALL TRADES.
8. CENTER LINEAR SLOT DIFFUSER ON WALL DIRECTLY
ABOVE FURR-OUT ABOVE UPPER CABINETS.
9. IN ALL FULLY INACCESSIBLE CEILING LOCATIONS FOR
EACH INLINE DUCT MANUAL BALANCING DAMPER, PROVIDE
SELF LOCKING, WORM GEAR DRIVEN HANDLE WITH
FLEXIBLE SHAFT, CONNECTOR AND PAINT-GRIP, MILL FINISH
COVER PLATE (PRIME/PAINT TO MATCH ADJACENT FINISH).
COORDINATE WITH EXACT FINAL CEILING PLAN PRIOR TO
ROUGH-IN AND INSTALLATION.
SCALE: 1/4"=1'-0"
CO
IN
MA
CH
CA
SH
SA
FE
DR
IV
E T
HR
U
BA
NK
ER
S
109
DR
IV
E T
HR
U
ST
OR
108
NIG
HT
DE
P
CO
RR
115
CO
RR
110
CO
RR
132
RE
SO
UR
CE
126
LO
BB
Y
101
BA
NK
ER
S
104
BA
NK
ER
S
103
VIE
WIN
G
106
ST
OR
AG
E
125
OF
FIC
E
111
OF
FIC
E
112
OF
FIC
E
113
OF
FIC
E
114
WO
ME
N
116
ME
N
117
BR
EA
K R
OO
M
120
RJ O
FF
IC
E
131
RJ O
FF
IC
E
129
RJ R
ES
OU
RC
E
128
RJ R
EC
EP
TIO
N
127
F
NIG
HT
D
RO
P
ST
OR
121
DE
AL
DR
WR
CA
SH
RE
C
UC
SN
IG
HT
DE
P
1
23
45
6
11
10
98
7
12
13
14
15
24
18
16
17
23
20
19
21
22
VA
UL
T
105
CO
NF
ER
EN
CE
122
ME
CH
/E
LE
C/IT
119
JA
NIT
OR
118
AD
MIN
107
VE
ST
IB
UL
E
100
WC
URH
LH
EWCH
S1/DSP
SS
LH
LH
LH
3"FD/TP
4"CO
4"DCO
1
4"
3"
4"
3"VTR
3" U/G
3" STORM LEADER
DOWN IN INTERIOR
FURRING
3" U/S
3"
3" U/S
3" STORM
LEADER DN
4" U/G
3
3"
3
4
4"
5 6
4" U/G (1/2" SLOPE)
WCH
4"
4"
WCH
4" (1/4" SLOPE)
3"FD/TP3"FD/TP
7
4"DSN
6"U/G
4" STORM LEADER CONCEALED
DOWN IN INTERIOR 6" STUD WALL
OUTSIDE OF CONCRETE VAULT
WALL CONSTRUCTION (TYP 2)
3
4"DSN
4" STORM LEADER DOWN,
CONCEALED IN WALL
4" (1/4" SLOPE)
8
©
5201 S. Broadway Avenue,
Suite 200
Tyler, Texas 75703
903.592.0728
903.595.0369 fax
info@fitzpatrickarchitects.com
11/01/17
JOB NUMBER
SHEET NUMBER
16.106
DATE
E
D
C
B
A
1 2 3 4 5 6
SO
UT
HS
ID
E B
AN
K
SO
UT
H B
RO
AD
WA
Y B
RA
NC
H
TY
LE
R, T
X
SHEET REVISION HISTORY
PROJECT MANAGER
EDDIE LACROIX
IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1")
EXACTLY, THIS DRAWING HAS BEEN ENLARGED OR REDUCED,
AFFECTING ALL LABELED SCALES.
ROGER H. BARNES, P.E.
107023
THESE DRAWINGS DO NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY.
17-023
ENGINEER:
LICENSE NO.
CONSULTING ENGINEERS
FIRM REGISTRATION NO. 667
3003 KNIGHT STREET, SUITE 120
SHREVEPORT, LOUISIANA 71105
phone: 318-425-7452 fax: 318-425-4622
www.AFJMc.com
COPYRIGHT NOTICE:
THIS ENGINEERING DRAWING SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH AFJMC. NO
OTHER USE DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF AFJMC.
ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
PLUMBING PLANS
(WASTE/VENT/STORM)
M301
1. SEE CIVIL SITE PLAN FOR CONTINUATION OF UTILITY
PIPING.
2. COORDINATE EXACT LOCATION OF ALL ROOF DRAINS
WITH ARCHITECTURAL PLANS AND ROOF INSULATION SHOP
DRAWINGS PRIOR TO ROUGH-IN AND INSTALLATION.
PRIMARY ROOF DRAIN PIPING SHALL BE INSULATED AND
INSTALLED AT 1/8" SLOPE PER FOOT, UNLESS NOTED
OTHERWISE. SECONDARY ROOF DRAIN PIPING SHALL BE
INSTALLED AT 1/8" SLOPE PER FOOT, UNLESS NOTED
OTHERWISE. EXTEND SECONDARY ROOF DRAIN PIPING TO
EXTERIOR, TERMINATE THROUGH DOWNSPOUT AT 8"
ABOVE FINISHED FLOOR LEVEL AS DETAILED. COORDINATE
CONCEALMENT OF EACH STORM PIPING SYSTEM WITHIN
BUILDING CONSTRUCTION WITH ARCHITECT PRIOR TO
ROUGH-IN AND INSTALLATION.
3. EXTEND, CONNECT AND TERMINATE INTO EXTERIOR
UNDERGROUND BUILDING PERIMETER STORM DRAINAGE
PIPING. (RE: CIVIL)
4. INSTALL CLEANOUT FLUSH IN CONCRETE FLATWORK.
5. PROVIDE SIDE INLET FITTING IN P-TRAP OF ADJACENT
DOUBLE COMPARTMENT SINK. EXTEND AND CONNECT
DISHWASHER DISCHARGE TUBING AS DIRECTED BY
MANUFACTURER.
6. PRIOR TO SINK ROUGH-IN AND INSTALLATION,
COORDINATE SINK/DISPOSER INSTALLATION TO FULLY
ACHIEVE TAS COMPLIANCE; REFERENCE ARCHITECTURAL
PLANS AND DETAILS.
7. CONCEAL 3" STORM PIPE IN WALL AND IN CANOPY.
8. NO PIPES AND/OR ASSOCIATED PIPE PENETRATIONS
SHALL BE ALLOWED IN VAULT/VAULT CONSTRUCTION.
SCALE: 1/4"=1'-0"
CO
IN
MA
CH
CA
SH
SA
FE
DR
IV
E T
HR
U
BA
NK
ER
S
109
DR
IV
E T
HR
U
ST
OR
108
NIG
HT
DE
P
CO
RR
115
CO
RR
110
CO
RR
132
RE
SO
UR
CE
126
LO
BB
Y
101
BA
NK
ER
S
104
BA
NK
ER
S
103
VIE
WIN
G
106
ST
OR
AG
E
125
OF
FIC
E
111
OF
FIC
E
112
OF
FIC
E
113
OF
FIC
E
114
WO
ME
N
116
ME
N
117
BR
EA
K R
OO
M
120
RJ O
FF
IC
E
131
RJ O
FF
IC
E
129
RJ R
ES
OU
RC
E
128
RJ R
EC
EP
TIO
N
127
F
NIG
HT
D
RO
P
ST
OR
121
DE
AL
DR
WR
CA
SH
RE
C
UC
SN
IG
HT
DE
P
1
23
45
6
11
10
98
7
12
13
14
15
24
18
16
17
23
20
19
21
22
VA
UL
T
105
CO
NF
ER
EN
CE
122
ME
CH
/E
LE
C/IT
119
JA
NIT
OR
118
AD
MIN
107
VE
ST
IB
UL
E
100
WCHWCH
WCURH
LH/MV
EWCH
S1/DSP
SS
LH/MV
LH/MV
LH/MV
WH
IOB
2"
1
WF
WF
3/4"
3/4"
3/4"
1"
3/4"H&CW DOWN
1"
1 1/2"
2
3
TYP
2"
1 1/4"
©
5201 S. Broadway Avenue,
Suite 200
Tyler, Texas 75703
903.592.0728
903.595.0369 fax
info@fitzpatrickarchitects.com
11/01/17
JOB NUMBER
SHEET NUMBER
16.106
DATE
E
D
C
B
A
1 2 3 4 5 6
SO
UT
HS
ID
E B
AN
K
SO
UT
H B
RO
AD
WA
Y B
RA
NC
H
TY
LE
R, T
X
SHEET REVISION HISTORY
PROJECT MANAGER
EDDIE LACROIX
IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1")
EXACTLY, THIS DRAWING HAS BEEN ENLARGED OR REDUCED,
AFFECTING ALL LABELED SCALES.
ROGER H. BARNES, P.E.
107023
THESE DRAWINGS DO NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY.
17-023
ENGINEER:
LICENSE NO.
CONSULTING ENGINEERS
FIRM REGISTRATION NO. 667
3003 KNIGHT STREET, SUITE 120
SHREVEPORT, LOUISIANA 71105
phone: 318-425-7452 fax: 318-425-4622
www.AFJMc.com
COPYRIGHT NOTICE:
THIS ENGINEERING DRAWING SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH AFJMC. NO
OTHER USE DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF AFJMC.
ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
PLUMBING PLANS
(WATER)
M302
1. SEE CIVIL SITE PLAN FOR CONTINUATION OF UTILITY
PIPING.
2. WATER HEATER INSTALLED ABOVE SERVICE SINK;
SHOWN OFFSET FOR CLARITY. OFFSET/COORDINATE WITH
MOP HANGER BRACKET INSTALLATION.
3. EXTEND PIPE DROPS AS INDICATED; CONNECT TO
PLUMBING FIXTURES WITH INDIVIDUAL BRANCH SIZES AS
SCHEDULED.
SCALE: 1/4"=1'-0"
85
6
3
11
10
14
2
9
1/4" : 1
2"
RD
1/4" : 12"
RD
RD
OD
OD
OD
RD
OD
1/4" : 12"
1/4" : 12"
12" : 1
2"
12" : 1
2"
12" : 12"
12" : 12"
RD
1/4" : 12"
1
/
4
"
:
1
2
"
1
/
4
"
:
1
2
"
RD
RD
RD
RD
RD
4" RD 4" SRD
4" RD4" SRD
4" RD4" SRD
3" RD
3" RD
4" RD
4" SRD
3" RD
3" RD
3" RD
3" RD
RTU-1
RTU-2
RTU-3
CU-A
CO
1 1/4"
1 1/4"
1 1/2"
1 1/2"
5
1 4
CO
C
C
C
1"
3
TYP
EXHAUST HOOD
2
TYP 4
7
7
6
©
5201 S. Broadway Avenue,
Suite 200
Tyler, Texas 75703
903.592.0728
903.595.0369 fax
info@fitzpatrickarchitects.com
11/01/17
JOB NUMBER
SHEET NUMBER
16.106
DATE
E
D
C
B
A
1 2 3 4 5 6
SO
UT
HS
ID
E B
AN
K
SO
UT
H B
RO
AD
WA
Y B
RA
NC
H
TY
LE
R, T
X
SHEET REVISION HISTORY
PROJECT MANAGER
EDDIE LACROIX
IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1")
EXACTLY, THIS DRAWING HAS BEEN ENLARGED OR REDUCED,
AFFECTING ALL LABELED SCALES.
ROGER H. BARNES, P.E.
107023
THESE DRAWINGS DO NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY.
17-023
ENGINEER:
LICENSE NO.
CONSULTING ENGINEERS
FIRM REGISTRATION NO. 667
3003 KNIGHT STREET, SUITE 120
SHREVEPORT, LOUISIANA 71105
phone: 318-425-7452 fax: 318-425-4622
www.AFJMc.com
COPYRIGHT NOTICE:
THIS ENGINEERING DRAWING SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH AFJMC. NO
OTHER USE DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF AFJMC.
ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
MECHANICAL
ROOF PLAN
M401
1. PROVIDE ROOF PIPE SUPPORTS FOR CONDENSATE
PIPING EQUAL TO PHP WITH ROOF MEMBRANE PADS.
PROVIDE AT INTERVALS OF EIGHT FEET ON CENTER
(MINIMUM) AND WITHIN THREE FEET OF EACH CHANGE OF
DIRECTION.
2. FROM DRIVE-THRU CANOPY ROOF DRAIN, DROP 3"
STORM LEADER CONCEALED DOWN IN VERTICAL
ENCLOSURE BELOW (RE: ARCH) PARALLEL TO ADJACENT
STRUCTURAL MEMBER. TERMINATE ABOVE GRADE
THROUGH ENCLOSURE SIDE NEAR BASE WITH 3"
DOWNSPOUT NOZZLE AS DETAILED.
3. COORDINATE EXACT LOCATION OF ALL ROOF DRAINS
WITH ARCHITECTURAL PLANS AND ROOF INSULATION SHOP
DRAWINGS PRIOR TO ROUGH-IN AND INSTALLATION.
4. PROVIDE ROOF EQUIPMENT SUPPORTS (4 PER UNIT, ONE
AT EACH CORNER) FOR ROOF MOUNTED HVAC
CONDENSING UNIT, EQUAL TO PORTABLE PIPE HANGER
(PPH) MODEL RTU-20 WITH ROOF MEMBRANE PADS
MATCHING AND COMPLIANT WITH ROOFING SYSTEM.
ROUTE INSULATED REFRIGERANT PIPING THROUGH ROOF
WITH WEATHERPROOF SEALED PENETRATION EQUAL TO
PATE PIPE SEAL; FLASH AND SEAL WEATHERPROOF
THROUGH ROOF. ROUTE ABOVE CEILING SPACE TO
RESPECTIVE UNIT AS REQUIRED. CONFIGURE UNITS TO
ACHIEVE AND MAINTAIN ALL REQUIRED CLEARANCES.
5. EXTEND AND TERMINATE CONDENSATE DRAIN PIPE (SIZE
AS NOTED) TO NEAREST ADJACENT ROOF DRAIN (NOT
SECONDARY ROOF DRAIN).
6. REFERENCE ARCHITECTURAL PLANS FOR EXACT RTU
LOCATIONS. COORDINATE WITH ROOF AND STRUCTURE AS
REQUIRED. MAINTAIN ALL ACCESS, CODE, SERVICE AND
OPERATIONAL REQUIRED CLEARANCES.
7. ROOF DRAIN TO BE LOCATED IN LOWER LEVEL ROOF
CONSTRUCTION. REFERENCE ARCHITECTURAL PLANS AND
DETAILS AS REQUIRED PRIOR TO ROUGH-IN AND
INSTALLATION.
SCALE: 3/16"=1'-0"
©
5201 S. Broadway Avenue,
Suite 200
Tyler, Texas 75703
903.592.0728
903.595.0369 fax
info@fitzpatrickarchitects.com
11/01/17
JOB NUMBER
SHEET NUMBER
16.106
DATE
E
D
C
B
A
1 2 3 4 5 6
SO
UT
HS
ID
E B
AN
K
SO
UT
H B
RO
AD
WA
Y B
RA
NC
H
TY
LE
R, T
X
SHEET REVISION HISTORY
PROJECT MANAGER
EDDIE LACROIX
IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1")
EXACTLY, THIS DRAWING HAS BEEN ENLARGED OR REDUCED,
AFFECTING ALL LABELED SCALES.
ROGER H. BARNES, P.E.
107023
THESE DRAWINGS DO NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY.
17-023
ENGINEER:
LICENSE NO.
CONSULTING ENGINEERS
FIRM REGISTRATION NO. 667
3003 KNIGHT STREET, SUITE 120
SHREVEPORT, LOUISIANA 71105
phone: 318-425-7452 fax: 318-425-4622
www.AFJMc.com
COPYRIGHT NOTICE:
THIS ENGINEERING DRAWING SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH AFJMC. NO
OTHER USE DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF AFJMC.
ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
MECHANICAL
DETAILS
M501
ACOUSTICALLY
LINED STEEL
HOUSING
CEILING
VIBRATION ISOLATORS
HANGER RODS
SECURE TO
STRUCTURE
ALUMINUM GRILLE
EXHAUST DUCT TO
DISCHARGE
FLEXIBLE
CONNECTION
DISCHARGE OUTLET WITH
BACKDRAFT DAMPER
S/A DUCT
CEILING AND
T-BAR SYSTEM BY
OTHERS
R-8 MINIMUM SUPPLY
AIR FLEX DUCT (R8
MIN); MAX 5'-0"
3" THICK,
3
4
" LB/FT
DENSITY DUCT
WRAP INSULATION
DIFFUSER
RE: SCHEDULE
RETURN AIR
DUCT
3" THICK,
3
4
" LB/FT
DENSITY DUCT
WRAP INSULATION
LINED R/A
PLENUM
CEILING AND
T-BAR SYSTEM BY
OTHERS
RETURN AIR GRILLE
RE: SCHEDULE
RECTANGULAR
DUCT
ROUND DUCT
SEAL OPENING AIRTIGHT
VOLUME DAMPER WITH END
BEARING & OPERATOR
RECTANGULAR DUCT
VOLUME DAMPER WITH END
BEARING & OPERATOR
RECTANGULAR
DUCT
RECTANGULAR
DUCT
VOLUME DAMPER WITH END
BEARING & OPERATOR
RIGID ROUND DUCT OR
FLEXIBLE DUCT
RECTANGULAR TO ROUND
TRANSITION FITTING
SEAL OPENING AIRTIGHT
NOTE: USE HIGH
PERFORMANCE TAKE-OFFS
SEAL OPENING AIRTIGHT
1
1
2
" STAND-OFF
BRACKET ASSEMBLY
MANUAL LOCKING
QUADRANT WITH
DEGREE GRADUATIONS
CEILING CEILING DIFFUSER
SEAL PERIMETER AIR
AND VAPOR TIGHT
GREENHECK MBDR-50
EXTENSION & DAMPER OR
EQUAL BY RUSKIN
MOLDED SYNTHETIC
SLEEVE-TYPE END
BEARINGS
3
8
" SQUARE SHAFT
45° SIDE TAKE-OFF
FLEX DUCT AND HARD
ROUND DUCT ELBOW SAME
SIZE AS DIFFUSER NECK
MOLDED SYNTHETIC
SLEEVE-TYPE
INTERMEDIATE BEARING
6" THK. BATT
INSULATION BLANKET
OVER ENTIRE BACKPAN
2
"
ENDS OF LINER SHALL BE
BUTTED FIRMLY TOGETHER
ALTERNATE
POSITION
OF BOLT
FLANGED CONNECTION ON
FAN SIDE
WASHER
1" FLANGE & HEM
BOLT ON 4" CENTERS
1"x
1
8
"IRON BAND
FLEXIBLE MATERIAL
AS SPECIFIED
1
1
2
"POCKET SLIP
DUCT
1
1
2
"-3" INSTALLED; 6"
NOMINAL WITH
MATERIAL TAUT
SHEET METAL AS
SPECIFIED FOR
DUCTWORK
GALV DUCT
2" DUCT LINER
GALV. DUCT
2" DUCT LINER
LINER TO BE ADHERED TO
DUCT WITH 100% ADHESIVE
(MIRACLE PF 96)
TOP & BOTTOM SECTION
OF LINER SHALL
OVERLAP THE SIDES
ALL ENDS OF LINER TO BE
COATED WITH ADHESIVE
(MIRACLE PF 96)
NOT MORE THAN 2" FROM
EDGE OF LINER
1
2
"
M
A
X
(
T
Y
P
)
(RIGID CEILING SIMILAR) (RIGID CEILING SIMILAR)
PERFORATED GALV.
SHEET METAL
RIGID ROUND DUCT
ELBOW (SAME SIZE AS
DIFFUSER NECK)
4
5
°
4
5
°
4
5
°
ATTACH TO STRUCTURE
ABOVE AS NOTED
3
8
" ALL THREAD ROD
ROUND SUPPLY
AIR DUCT
20 GA BENT
METAL HALF
STRAP AS NOTED
PRIME AND PAINT DUCT
SUPPORT/COMPONENTS
TO MATCH DUCT
OPENING THRU
ROOF AT DUCT
PENETRATIONS
ONLY
DOUBLE WALL
SUPPLY OR
RETURN DUCT
2 LAYERS OF 6" FIBERGLASS BATT
INSULATION FOR NOISE CONTROL
CONTINUOUS
NEOPRENE GASKET
ROOFTOP UNIT BASE RAIL GASKET STRIP BY
A/C UNIT MANUFACTURER
ROOFTOP UNIT (RTU)
VIBRATION ISOLATOR (AS SCHEDULED)
ROOF
ROOFING & FLASHING
(SEE ARCH)
PREFABRICATED
INSULATED ROOF
CURB (VERIFY AND
MATCH ROOFING
SYSTEM WITH ARCH)
26 GA GALV FLASHING AND
COUNTER FLASHING WITH ROOF
FELT AS RECOMMENDED BY ROOF
MANUFACTURER
PROVIDE A CONTINUOUS
METAL TERMINATION
BAR WITH PRE-DRILLED
HOLES, SCREW TO ROOF
CURB & SEAL WITH NP-1
SEALANT
WOLMANIZED WOOD NAILER, CANT
STRIP & 2" RIGID INSULATION BY CURB
MANUFACTURER
RL
RS
HEAT PUMP
UNIT
ROOF
SIGHT GLASS
DUCTLESS AIR HANDLING
MODULE (EXACT TYPE AS
SCHEDULED)
FLASH, COUNTERFLASH,
AND SEAL WEATHERTIGHT
COMPLIANT WEATHERTIGHT PIPE
ROOF PENETRATION
JACK/SLEEVE
CORNER MOUNTED ROOF EQUIPMENT
SUPPORTS (COMPLIANT WITH ROOFING
SYSTEM WARRANTY)
PUMPED CONDENSATE
DRAIN (TERMINATION
POINT AS INDICATED PER
PLAN)
C
PROVIDE REINFORCING
AROUND FULL PERIMETER
(VERITY WITH STRUCTURAL)
EXHAUST
AIR DUCT
BUILT-UP ROOF
CURB
EXHAUST HOOD
ROOF DECK
(RE: ARCH)
FIXED BACKDRAFT
DAMPER, SPRING RETURN
PRIME/PAINT TO MATCH
ROOF FINISH WHERE
VISIBLE FROM EXTERIOR
COORDINATE WITH EXACT
ROOF TYPE, SLOPE, ETC.
PER ARCHITECTURAL
INSULATED REFRIGERANT
PIPING SYSTEM SETS AS
SPECIFIED; EXACT SIZE IN
STRICT ACCORDANCE
WITH MANUFACTURER
REQUIREMENTS
FINISHED
FLOOR
EXTERIOR
WALL
TO/FROM
CONDENSER
WALL MOUNTED
UNIT WITH INTEGRAL
CONDENSATE PUMP
TYPE "L" HARD COPPER
BACK UNIT PIPING
CONNECTIONS;
EXTEND CONDENSATE
PIPING AS SHOWN ON
PLANS
REFRIGERANT PIPING SHALL BE HARD COPPER WITH FITTINGS
AND INSTALLED LEVEL AND PLUMB. WALL MOUNTED UNITS SHALL
HAVE REFRIGERANT AND CONDENSATE PIPING ROUTED WITHIN
WALL WITH BACK UNIT CONNECTIONS. EXPOSED REFRIGERANT
AND CONDENSATE PIPING TO HAVE METAL JACKETED INSULATION.
©
5201 S. Broadway Avenue,
Suite 200
Tyler, Texas 75703
903.592.0728
903.595.0369 fax
info@fitzpatrickarchitects.com
11/01/17
JOB NUMBER
SHEET NUMBER
16.106
DATE
E
D
C
B
A
1 2 3 4 5 6
SO
UT
HS
ID
E B
AN
K
SO
UT
H B
RO
AD
WA
Y B
RA
NC
H
TY
LE
R, T
X
SHEET REVISION HISTORY
PROJECT MANAGER
EDDIE LACROIX
IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1")
EXACTLY, THIS DRAWING HAS BEEN ENLARGED OR REDUCED,
AFFECTING ALL LABELED SCALES.
ROGER H. BARNES, P.E.
107023
THESE DRAWINGS DO NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY.
17-023
ENGINEER:
LICENSE NO.
CONSULTING ENGINEERS
FIRM REGISTRATION NO. 667
3003 KNIGHT STREET, SUITE 120
SHREVEPORT, LOUISIANA 71105
phone: 318-425-7452 fax: 318-425-4622
www.AFJMc.com
COPYRIGHT NOTICE:
THIS ENGINEERING DRAWING SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH AFJMC. NO
OTHER USE DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF AFJMC.
ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
PLUMBING
DETAILS
M502
CLEANOUT BOX WITH CI LID SET IN
14" SQ CONC BOX
CLEANOUT BOX WITH CI LID SET IN
14" SQ CONC BOX
CLEANOUT BOX WITH CI LID SET IN
14" SQ CONC BOX
6" CONC PAD REINFORCED
WITH 6"x6"x
1
4
" WIRE MESH
6" CONC PAD
REINFORCED WITH
6"x6"x
1
4
" WIRE MESH
LONG SWEEP ELBOW
SEWER LINE
COVER WYE
FITTING
14"x14"x6" CONCRETE
PAD WITH CHAMFER
EDGES
CAST IRON
VALVE BOX
GATE VALVE
CAST IRON COVER
MARKED "WATER"
NOTES:
1. PROVIDE FIRE STOP SEAL BETWEEN VENT PIPE AND
INSIDE OF SLEEVE.
2. PRIME AND PAINT TO MATCH ROOF FINISH.
ROLL DOWN INTO
PIPE, 1" MIN
LEAD FLASHING
SLEEVE
STRIPPING
ROOF
VENT THRU ROOF
SLEEVE ROOF
CONSTRUCTION
CAST IRON
MUSHROOM DOME
FLASH & COUNTERFLASH; COORDINATE
WITH ROOFING MANUFACTURER'S
INSTRUCTIONS
CONCRETE EXPANSION
ANCHOR EQUAL TO HILTI
UNDERDECK CLAMP
INSULATE ROOF DRAIN
PIPING PER SPECIFICATIONS
INSULATION TAPERED TO
DRAIN; COORDINATE WITH
ROOF INSULATION SHOP
DRAWINGS
ROOFING SYSTEM
ROOF DECK
3"x3"x3/8"
STEEL ANGLE
5/8" GALVANIZED
ALL-THREAD
HANGER RODS
CLEANOUT
2"x
3
8
" THICK BENT
STEEL STRAP
SECONDARY ROOF DRAIN (SRD) - SIMILAR
HOT WATER
SUPPLY
COLD WATER
SUPPLY
VACUUM
RELIEF
VALVE
WATER
HEATER
DRAIN VALVE;
TERMINATE AS
NOTED ON PLANS
FINISHED FLOOR
POTABLE WATER
EXPANSION TANK
18" M
AX
.
P&T RELIEF
VALVE
HOLDRITE QUICKSTAND
WITH INTEGRAL DRAIN;
SUSPENDED FROM
STRUCTURE ABOVE BY
1
2
"Ø
ALLTHREAD ROD ON EACH
CORNER (6'-6"AFF, MIN)
A
DRAWTHRU:
A = PER MANUFACTURER'S RECOMMENDATIONS
NOTES:
1. 1"Ø MIN PIPE SIZE OR SIZE PER DRAIN TAP IN
AHU, INSULATE FOR CONDENSATE CONTROL.
2. AIR GAP REQUIRED IN CONDENSATE LINE TERMINATIONS.
AIR
HANDLING
UNIT
THREADED TEE, WITH EXTENDED
NECK AND CAP FOR CLEANING
TRAP
1"
(INTERIOR)
A
DRAWTHRU:
A = PER MANUFACTURER'S REQUIREMENTS
NOTES:
1. PIPE SIZE AS NOTED.
2. AIR GAP REQUIRED IN CONDENSATE LINE TERMINATIONS.
ROOFTOP
UNIT
THREADED TEE, WITH EXTENDED
NECK AND CAP FOR CLEANING
TRAP
PAINTED
SCH 80 PVC
(EXTERIOR)
LAVATORY / SINK
KEYED ANGLE STOPS
ADJUSTABLE
POINT-OF-USE
MIXING VALVE
NOTES:
1. PROVIDE ROOF PAD AS RECOMMENDED BY ROOFING MANUFACTURER.
2. PIPE SUPPORT SHALL BE PORTABLE PIPE HANGERS, INC. MODEL SS-8C FOR
CONDENSATE PIPING OR APPROVED EQUAL.
3. ALL METAL RODS, WASHERS, NUTS, BOLTS, CLAMPS, ETC. SHALL BE HOT
DIPPED GALVANIZED (ASTM A123).
4. SUPPORTS SIZED AND SPACED AS NOTED.
5. MINIMUM BASE SIZE IS 10"x16".
6. PIPE SIZES 2
1
2
" AND SMALLER COMBINED ON SAME BASE.
CONTINUOUSLY INSULATED
CONDENSATE PIPING
GALVANIZED STEEL
ADJUSTABLE TO 12"
ROOF HIGH DENSITY POLYPROPYLENE
BASE WITH UV INHIBITOR
1
2
" MIN STEEL ROD
WASHERS & NUTS
MEMBRANE ROOF PAD
PIPE ROLLER
PIPING; PAINT AS
INDICATED
ROOF
ELCEN FIG. 18 ADJ.
ROLLER ASSEMBLY
3
1
2
" PIPE & LARGER
ELCEN #221 STYLE 1
SADDLES
3
4
" MIN HANGER
RODS
ELCEN FIG. 625
ROLLER 3" PIPE &
SMALLER
ELCEN #221
STYLE 2
SADDLE
HANGER ROD
3
4
"-LESS THAN 2"
3
8
"-UP TO 2"
5
8
"-UP TO 6"
3
4
"-UP TO 6"
ADJUSTABLE CLEVIS
HANGER, GRINNELL FIG.
260 OR ELCEN FIG. 12
ALL SYSTEMS LINES
GROUP SUPPORT
KLO-SHURE INSULATION
COUPLING OR EQUAL
KLO-SHURE INSULATION
COUPLING OR EQUAL
CONDENSATE PIPING
GALVANIZED STEEL
ADJUSTABLE TO 12"
KLO-SHURE INSULATION
COUPLING OR EQUAL
CONTINUOUSLY INSULATED
REFRIGERANT PIPING (TYP)
PIPE CLAMP WITH KLO-SHURE
INSULATION INSERT FOR
CONTINUOUS INSULATION AT
CLAMP CONNECTION (TYP)
CONTINUOUSLY INSULATED
REFRIGERANT PIPING (TYP)
STORM
DRAIN PIPE
EXTERIOR WALL
CONSTRUCTION
PIP
E S
IZ
E
STAINLESS STEEL
DOWNSPOUT NOZZLE
WITH HINGED COVER
4 HOLES AT 90° FOR
1/4" FLAT HEAD
MACHINE SCREWS
8"AFF