Slit Lamp Adapted Optical Coherence Tomography
SL SCAN-1
Optical Coherence Tomography (OCT) technology createda revolution in the fundus diagnostic field more than a decade ago. With the introduction of the world’s first commercialised Fourier Domain OCT, 3D OCT-1000 in 2005, Topcon made a further revolution in this field offering the combination ofa retinal camera with high resolution 3D OCT image.
Topcon is proud to introduce the world’s first slit lamp adapted posterior and anterior segment Fourier Domain OCT, SL SCan-1. With the SL SCan-1, OCT examination becomes available from the first consultation increasing efficiency and accuracy of diagnosis. Patient comfort is also improved by reduction in examination time.
OCT digital network in the clinic
Examination Room
Dark Room
Operation Room
Consultation Room
Laser Treatment Room
Doctors Room
Server Room
VA test Room
Examination Room
Consultation Room
Further detailed diagnostic tests
First consultation with the SL SCAN-1
Consultation Room Dark Room
Ultimate Optimisation of Patient Flow by the SL SCAN-1
The Topcon SL SCAN-1 enables observation, capture and recording of high resolution cross-sectional images of the anterior and posterior pole of the eye with a biomicroscope. The integration of superior imaging technology, OCT with Topcon’s leading slit lamp range enhances diagnostic capabilities significantly. With SL SCAN-1 many depth related disorders can be clearly and easily observed using a standard slit lamp examination.
With the SL SCAN-1, OCT examination becomes available from the first consultation.
The SL SCAN-1 requires minimal operation to obtain the desired OCT B-Scan images. A simple, compact addition to Topcon’s digital range of slit lamps the SL SCAN-1 does not sacrifice a single function of the Topcon slit lamp.The high resolution OCT image provides detailed and precise readings for further treatments such as Fluorescein fundus photography, 3D OCT scanning and the follow up of surgery, laser treatment and anti VEGF injection.
Retina with pathologies
Healthy Retina
1
3
2a
2b
Image courtesy of Carlos Mateo, MD – IMO Barcelona, Spain
Surgery, Laser Treatment and/or Anti-VEGF injection
Consultation RoomOperation Room
Follow up by the SL SCAN-1
IMAGEnet i-baseTM
IMAGEnet i-base connection realises the ultimate digital connection between the SL SCAN-1 and other state of art Topcon instruments such as 3D OCT, Fundus imaging systems, Refraction systems etc.
45
Image courtesy of Carlos Mateo, MD – IMO Barcelona, Spain
The SL SCAN-1 Clinical Image Samples
Cornea + Contact Lens
neovascularisation
at border of old
chorioretinal scar
(treated with PDT;
without leakage)
Iris Cyste
(scan from Radial
Scan Pattern)
Occult neovascularisation
in aMD, Pigment
Epithelial Detachment
still present and (sub)
retinal edema subsided
Idiopathic
neovascularisation
The SL SCAN-1 provides high resolution OCT images of the posterior and anterior section.
The B-Scan length of the SL SCAN-1 on the fundus is 12mm wide covering approximately 40 degrees of the fundus view providing scanning of a large peripheral area of the fundus.
Using Topcon SL SCAN-1 in combination with an add-on digital camera allows the user to record an en-face image taken by the camera and the cross section image taken by the OCT system simultaneously. Both can be stored on standard PC allowing you to view and analyse data at a later stage.
Various Scan Patterns
The SL SCAN-1 is equipped with the various scan patterns for your desired use.
All scan patterns are configurable in number of B-scan lenghts and resolution.
With the SL SCAN-1, B-scan acquisition of the peripheral retina is possible.
Horizontal Horizontal rasterCross
Grid Circle
With the SL SCAN-1, B-scan acquisition is possible on any part of the retina including extreme peripheral area using a hand held lens.
Full 12mm scan on retina allows the user to capture both macula and optic disc in one B-Scan.
Radial
0
0123456789
0
1
01234
0
1
2
34 5 6
7
8
9
98765
0
12 mm
Easy Operation of SL SCAN-1
The SL SCAN-1 requires minimal operation to obtain the desired OCT B-scan images, in fact the operation is so minimal that it does not sacrifice a single function of the Topcon slit lamp.
User can view the retina via hand held lens as usual.
The operator can press the joystick button to capture/record B-scan images, continuing to do so until the desired image is captured.
Once joystick is pressed, the scan line is projected on the retina/anterior chamber and the live B-Scan will be displayed on the monitor.
The user may report on the images captured to IMAGEnet i-base, where they can be viewed remotely via a network.
1
2
3
4
SL SCAN-1 Installation Examples
System Diagram
On the IS-600II ophthalmic furniture system. On the ATE-800 stand alone table system.
SL SCAN-1 scan unit (slit lamp attachment).
SL SCAN-1 base unit. (Vertical and horizontal placement possible).
The SL SCAN-1 System Configuration
Digital Camera Unit DC-3 / DV-3Digital Camera Unit DC-3 / DV-3
Slit Lamp Slit Lamp
SL SCAN-1SL SCAN-1
FV-1A
Fundus Viewer FV-1LFundus Viewer FV-1L
Fundus Viewing Systems
1) By handheld lens (Optional Accessories)
2) By Topcon Fundus Viewer System (Optional Accessories)
3) Image Recording Devices (Optional Accessories)
DV-3
• The DV-3 incorporates a digital camera designed for high-resolution image acquisition.
• A C-MOS sensor provides a resolution up to 3.14 million pixels in a 10-bit digital output.
• “What you see is what you get”. The image on the monitor screen is equal to the image seen through the oculars of the slit-lamp. With traditional SLR cameras this is not the case. DV-3 offers the best ease-of-use.
• The DV-3 mounts a yellow filter and diaphragm unit for improved image quality.
With SL SCAN-1 it is possible to use conventional handheld lenses to observe the retina and capture the OCT image.
Using the Topcon SL SCAN-1 in combination with an add-on digital camera DC-3 or DV-3 allows the user to record an en-face image with the automated digital scan line taken by the camera and the cross section image taken by the OCT system simultaneously.
Aperture Selector, FV-1A Reduces reflection to optimise the fundus observation.
(This unit can be used
independently from the SL SCAN-1
and/or FV-1L. It can be used with
the conventional lenses.)
Lens Holder, FV-1LApproximately 30 degree fundus image observed. With the combination of image recording devices such as the DC-3 or DV-3, the slit lamp can become a basic fundus camera.
(This unit can be used independently
from the SL SCAN-1 and/or FV-1A.)
Combination Overview
Handheld lens
o
o
-
-
FV-1L
-
-
o
o
FV-1A
-
o
-
o
Effect
Conventional view by handheld lens
Conventional handheld lens view with less reflection
30 degree wide fundus image
30 degree wide fundus image with less reflection
Both can be stored on a standard PC allowing you to view and analyse the data in later stage.
Digital Reference Scan Patterns
DC -3
• The DC-3 is the perfect combination for still imaging and live image.
• Integrated imaging solution with a phenomenal 8.3 Megapixel CCD sensor.
• Equipped with an exceptional resolution of 1 Megapixel life image.
PosteriorAnterior
Without the DC-3/DV-3, four kinds of digital drawing of various segments of eye are
available to record scanned area manually.
With or without the DC-3/DV-3, registration of scanned area can be recorded in the SL SCAN-1 software
(Standard Option).
With the DC-3/DV-3, scan pattern is automatically recorded on the retina / anterior image.
Item
cod
e: 5
2504
51 /
prin
ted
in E
urop
e / 0
8.09
TOPCON CORPORATION 75-1 Hasunuma-cho, Itabashi-ku, Tokyo 174-8580, Japan. Phone: 3-3558-2523/2522 Fax: 3-3960-4214 www.topcon.co.jp
Subject to change in design and/or specifications without advanced notice.
In order to obtain the best results with this instrument, please be sure to review all user instructions prior to operation.
TOPCON EUROPE
Topcon Europe Medical B.V.Essebaan 11; 2908 LJ Capelle a/d IJssel; P.O. Box 145;
2900 AC Capelle a/d IJssel; The Netherlands
Phone: +31-(0)10-4585077; Fax: +31-(0)10-4585045
E-mail: medical@topcon.eu; www.topcon.eu
Topcon DanmarkPraestemarksvej 25; 4000 Roskilde, Danmark
Phone: +45-46-327500; Fax: +45-46-327555
E-mail: info@topcondanmark.dk
www.topcondanmark.dk
Topcon Scandinavia A.B.Neongatan 2; P.O. Box 25; 43151 Mölndal, Sweden
Phone: +46-(0)31-7109200; Fax: +46-(0)31-7109249
E-mail: medical@topcon.se; www.topcon.se
Topcon España S.A.HEAD OFFICE; Frederic Mompou, 4;
08960 Sant Just Desvern; Barcelona, Spain
Phone: +34-93-4734057; Fax: +34-93-4733932
E-mail: medica@topcon.es; www.topcon.es
Topcon ItalyViale dell’ Industria 60;
20037 Paderno Dugnano, (MI) Italy
Phone: +39-02-9186671; Fax: +39-02-91081091
E-mail: topconitaly@tiscali.it; www.topcon.it
Topcon S.A.R.L.HEAD OFFICE; 89, rue de Paris; 92585 Clichy, France
Phone: +33-(0)1-41069494; Fax: +33-(0)1-47390251
E-mail: topcon@topcon.fr; www.topcon.fr
Topcon Deutschland GmbHHanns-Martin-Schleyer Strasse 41;
D-47877 Willich, Germany
Phone: (+49) 2154-885-0; Fax: (+49) 2154-885-177
E-mail: med@topcon.de; www.topcon.de
Topcon PortugalRua da Forte, 6-6A, L-0.22; 2790-072
Carnaxide; Portugal
Phone: +351-210-994626; Fax: +351-210-938786
www.topcon.pt
Topcon Polska Sp. z o.o.ul. Warszawska 23; 42-470 Siewierz; Poland
Phone: +48-(0)32-670-50-45; Fax: +48-(0)32-671-34-05
www.topcon-polska.pl
Topcon (Great Britain) Ltd.Topcon House; Kennet Side; Bone Lane; Newbury
Berkshire RG14 5PX; United Kingdom
Phone: +44-(0)1635-551120; Fax: +44-(0)1635-551170
E-mail: info@topcon.co.uk; www.topcon.co.uk
Topcon IrelandUnit 276, Blanchardstown; Corporate Park 2
Ballycoolin; Dublin 15, Ireland
Phone: +353-18975900; Fax: +353-18293915
E-mail: medical@topcon.ie; www.topcon.ie
Specifications SL SCAN-1
Axial resolution
Scan rate
Lateral resolution
Pixels image depth
Diopter range
Scan patterns
Scanning range
Light source (SLD)
Imaging segments
Aiming beam
Dimensions
Weight
Power source
Power dissipation
Specifications PC
Operating System
CPU
Memory
Connection
Screen resolution
Mouse
8 - 9 µm in tissue
5000 A-Scans / sec
≤ 20 µm
512 pixels
+/- 20 D
Horizontal line | Vertical line | Cross | Raster | Grid | Radial | Circle
2 - 12 mm Posterior
8 - 12 mm Anterior (10x)
2 - 4 mm Anterior (25x)
Wavelength 840 nm
Posterior segment
Anterior segment
Wavelength 650 nm
Base unit : W124 mm x H259 mm x L305 mm
Scan unit : W51 mm x H251 mm x L107 mm
Power unit : W89,5 mm x H45,5 mm x L188,9 mm
Base unit : 7 kg
Scan unit : 1 kg
Power unit : 0.8 kg
Voltage prim. 230 V 50/60 Hz / Frequency 50 – 60 Hz
Max. 80 W
recommended specifications
Microsoft Windows XP Professional (minimum SP2)
Microsoft Windows VISTA Business Edition (minimum SP1)
Pentium 4, 3.0 GHz or higher
2 GB or higher
USB2.0 Full Speed
1280 x 1024 (minimum 24 bit color quality)
with scroll wheel