Post on 07-Mar-2021
MODEL: SH - U6
by Bkav
w w w. s m a r t h o m e . b k a v. c o m
UGU6/V1.0/0914
893604393UGU6Mfr Code:
Copyright © 2014 Bkav SmartHome Co., Ltd. All rights reserved.
USER GUIDEIN-WALL URINAL SENSOR FLUSH VALVE
SH - U6
Bkav SmartHome technology company limited
Usage instruction
Electric shock may cause injuries or threats to life. Before installing, repairing or cleaning the device, you should check whether the device’s power is disconnected.
This work should be done by technicians or Customer Contact Center to avoid electric related accidents.
Environmental regulations must be complied when discard-ing or recycling the device or its wrapping.
Thank you for choosing in-wall urinal sensor flush valve SH - U6 of Bkav SmartHome. By selecting Bkav SmartHome’s products, you will get the best warranty service and installation support from our technicians.
This document gives useful information during installation and usage time. You should read and keep the manual carefully in case of need.
Warning
Copyright © 2014 Bkav SmartHome Co., Ltd. All rights reserved.
In-wall urinal sensor flush valve SH - U6 is the product of Bkav SmartHome and has been registered regarding design, utility solutions and quality certifi-cation. All violations such as copies of design and product idea are subject to the current copyright law of the Socialist Republic of Vietnam.
1
Content2
Usage notice
Safety instruction
Introduction
General introduction
Product package
Accessories
Device’s components
Sensing range
Specifications
Operating mode settings
How to set up operating mode
Operating mode settings
Installation
Step 1: Assemble the valve
Step 2: Assemble the valve with water pipe
Step 3: Assemble a protective frame on the receptacle box
Step 4: Install the receptacle box
1
4
5
5
5
6
7
8
9
11
11
11
12
12
13
14
15
3
16
17
18
19
20
22
22
23
24
26
29
Step 5: Disassemble the protective frame from the receptacle box
Step 6: Insert a battery box into the receptacle box
Step 7: Install a bend pipe
Step 8: Assemble the mounting frame with the receptacle box
Step 9: Assemble an aluminum frame with the mounting frame
Usage and maintenance
Usage steps
Maintenance during use
Operation cycle
Problem and Solution
Contact
Do not leave the device in high-temperature environment.
Do not disassemble the device if not necessary.
Do not clean the device with corrosive chemicals.
Safety instruction
Warning
Do not use voltage which is different from the one stated in the device’s specifications.
Disconnect the device’s power prior to any installation, disassembly or repair.
Safety instruction should be complied during the device usage.
4
General introduction
Product package
User guide (book) SH - U6
Introduction
The in-wall urinal sensor valve uses pyroelectric infrared radial sensor technology. When users are in the sensor area, the device will automatically flush water to clean the urinal. The product’s smart feature brings comfort, power saving and absolute safety to its users.
With modern and luxurious design, the device is suitable for hotels, business centers, airports, stations, public restrooms, etc.
5
MODEL: SH - U6
by Bkav
Accessories
Straight conduitconnector
Solenoid valve Flexible conduitconnector
Bend pipe Screw cover
M2x4 Screw M4x12 Screw
Protective frame
6
Device’s components
Infrared sensing component: transmits and receives infrared signal from users’ response in the sensor area, then notifying the central processor.Indicator light: has the notification function, the light is on when detecting a user in the sensor area.
Infrared sensing component
Indicator light
7
Sensing range
Range of receiving reflected signal Range of transmitting infrared signal
500 mm
250 mm
350 mm
15º
The sensing range can be adjusted from 40 cm to 60 cm based on installation conditions and customers’ needs.
Note
8
Specifications100-240V 50/60HzVoltage
Battery
Battery lifespan 2 years with 100 times/day(*)
Water consumption 2 - 4 liters/each time
Sensing range 60 cm max
Water supply pressure 0.7 - 7.6 Kgf/cm²
Configured wet flush 2 - 5 seconds
Configured clean flush 6 - 12 seconds
Automatic wet flush 12 hours
Water temperature 5ºC - 50ºC
Used water Clean water without residue
Dimensions (L x W x H)
Operating temperature 60ºC max
Weight 1.1 kg
110 x 130 x 132 mm
9
6V , 4AA
(*) The device’s lifespan can be longer or shorter depending on usage conditions and environment. The above durability is tested in standard conditions.Note
10
Operating mode settings
The urinal sensor valve is appropriate to all male urinals and usage conditions, the device can be adjusted flush time and sensing range.
How to set up operating mode
Operating mode settings
Wet flush:Clean flush:
2 seconds6 seconds
Default mode
Wet flush:Clean flush:
5 seconds10 seconds
Wet flush:Clean flush:
3 seconds8 seconds
Wet flush:Clean flush:
3 seconds8 seconds
Wet flush:Clean flush:
6 seconds12 seconds
11
1a: Assemble a straight conduit connector with the solenoid valve.1b: Assemble a flexible conduit connector with the solenoid valve.
Installation
Step 1: Assemble the valve as shown in figure (1)
12
1
Straight conduit connector
Solenoid valve
Flexible conduit connector
1a
1b
Filter
Note: The water pipe must be clean prior to assembly.Flexible conduit connector protrudes from the wall surface from 10 - 17 mm.
Step 2: Assemble the valve with a water pipe as shown in figure (2)
13
2
10 - 17 mm90 - 110 cm
150 mm
Step 3: Assemble a protective frame on the receptacle box
14
3
Protective frame
Receptacle box
After installing the receptacle box, remove the protective frame when mortar is dry.
Step 4: Install the receptacle box as shown in figure (4)
Protective frame
Receptacle box
15
4
Step 5: Disassemble the protective frame from the receptacle box as shown in figure (5)
16
5
Protective frame Receptacle box
Step 6: Insert a battery box into the receptacle box as shown in figure (6)
17
6
Battery box
Step 7: Install a bend pipe as shown on figure (7)
18
7
Flexible conduit connector
Screw cover
Step 8: Assemble the mounting frame with the receptacle box
19
8
Mounting frame
Battery connector
Valve connector
Power connector
Step 9: Assemble an aluminum frame with the mounting frame as shown in figure 9 & 10
20
9
Mounting frame
Aluminum frame
21
10
Aluminum frame
Tighten 2 screws to fix the aluminum frame.Wipe the device’s surface with a soft cloth after finishing installation.
Usage and maintenance
The urinal sensor valve is designed and manufactured based on pyroelectric infrared radial sensor technology, so it is safe to use. It will bring a comfortable and modern life to you thanks to its designed features.
Step 1: If a user moves in the sensor area, the indicator light will flash when using battery and it will be on when using electricity to notify detection of the user.Step 2: After 3 seconds, if it still detects the user in the front, the device will automatically open the valve for wet flush for 2 - 5 seconds (optional). Within 45 seconds after this flush, if there is user presence, it will not perform such wet flush again. This is smart feature to save water.Step 3: The device will wait until the user moves out of the sensor area, it will automatically flush the urinal cleanly for 6 - 12 seconds (optional).
3321
Usage steps
22
Maintenance during use
Glass maintenanceAfter operating in the moist and dusty environment for a time period, the device’s glass may be foul due to these factors. Thus, it is necessary to clean the glass.
Solenoid valve maintenance
After a period of usage, if flushing water becomes weaker or the valve starts leaking, it means the solenoid valve needs to be cleaned. This task should be done by technicians.
How to clean the solenoid valve:
Step 1: Disassemble the device’s glass and disconnect its power or battery supply.
Step 2: Disassemble the valve hose, leave the device’s front cover at dry place.
Step 3: Lock water supply for the valve.
Step 4: Disassemble the pipe which conveys water to the urinal.
Step 5: Use appropriate tool to remove the filter from the solenoid valve.
Step 6: Clean the valve filter.
Step 7: Reassemble and check the device’s feature.
Replace batteries
When the indicator light flashes every 1 second, it is time to replace batteries. The device uses 4 Alkaline 1.5V – AA batteries.
23
Operation cycle
Wet flush2 - 5 seconds
Clean flush6 -12 seconds
Wet flush2 - 5 seconds
Start
Presence of userPending time> 12 hours
Interval fromprevious user> 45 seconds
User leavesthe sensor area
True
True
False
False
False
True
True
True
False
False
Detection time> 3 seconds
Indicator lightflashes
24
After the preset time, the device will perform wet flush, flush duration is 2 - 5 seconds (optional). When detecting a user getting out of its sensor area, the device will continue to cleanly flush water for 6 - 12 seconds (optional). Within the next 45 seconds, in case of another user, it only cleanly flushes water for 6 - 12 seconds (optional) after detecting the user getting out of the sensor area.
If there is no other use in 45 seconds, it will automatically return to the initial procedure. It is the smart feature to save water during use.
If there is no other use for 12 hours, it will automatically flush water to rinse the urinal for 2 - 5 seconds (optional). This smart feature will make the urinal absolutely clean.
25
The device does not flush or stop flushing.CheckingThe valve is installed in the opposite direction and the water supply has a lot of residue.The solenoid valve is not connected to the controller. If the problem is not mentioned above.SolutionCheck the valve installation based on instruction steps in the manual.Connect the solenoid valve to the controller.Please contact Customer Contact Center or the shop from which you purchased.
The light flashes continuously (electric valve) or the device does not work properly.CheckingThere is any obstacle in the device’s sensor area.The device is installed on the opposite side of the mirror within 2.5 m.The device is close to light source from incandescent lamp.If the problem is not mentioned above.SolutionRemove the obstacle from the sensor area.Move the mirror because it reflects the infrared signal in the device’s sensing component.Adjust the direction of the light to avoid reflection towards the device or replace an energy-saving bulb.Please contact Customer Contact Center or the shop from which you purchased.
Problem and Solution
Problem 1
Problem 2
26
The indicator light does not flash when there is a user in the sensor area.
CheckingThe power line, battery wire are not connected correctly.A user wears full black coat or shirt (black leather jacket, black coat, etc.)
SolutionConnect the power cable, battery wire properly based on the steps in the manual.Black absorbs infrared signals fully so please put your hand in front of the transceiver eye so that the device flushes water. Please contact Customer Contact Center or the shop from which you purchased.
Flushing water is too much or too little.
CheckingThe device’s switches are not correctly set up based on its requirement.The device’s switch is adjusted but flushing water is still too much.
SolutionPlease refer to the mode settings in page 11 and follow the instructions to set up the mode correctly according to users’ needs.Please adjust pressure regulator of water supply because the water pressure at your place is too high.Please contact Customer Contact Center or the shop from which you purchased.
Problem 3
Problem 4
27
Other problems.
CheckingTechnicians misplaced the distance between the valve and the urinal (too far or too close), it is difficult to install the pipe.Water leak at the joints occurs.It is difficult to screw from the bottom because the performance scale is small.
SolutionYou can buy hoses at the sanitary equipment stores such as the type used for sink, measure suitable distance, cut and install.Please check the rubber gaskets, wrap thread seal tape (teflon tape) at the points of screws and the rubber stopper’s slots, etc.Short screwdrivers should be used. This type of screwdriver is sold at mechanical appliances shops.
Problem 5
Before contacting Customer Contact Center, please read the information in this section carefully to solve problems.
If assistance is required, please contact the shop from which you purchased or the nearest Customer Contact Center.
You need to note the product‘s serial number down before calling Contact Center because the warranty staffs will need such information.
Notice
28
Contact
If there is any problem related to the product, please contact Customer Contact Center:
Customer Contact Center: (+1) 202 386 6779Email: GlobalProject@bkav.com
29
T h e n e w h o m e s t a n d a r d !