Safety Switches & Enclosed Circuit BreakersSafety Switches

Cutler-HammerJanuary 2001

Vol. 1, Ref. No. [0230]

Options and AccessoriesTable 8-1. Safety Switches — Accessories

Description

Neutral Kits/Ground Kits30ADG60 - 100A DG200A DG, DH (NEMA 1, 3R Enclosures)30-60A DH100A DH200A DH (NEMA 4X, 12 Enclosures)400A DG, DH600A DG, DH400 - 600A Fusible DT, 800-1200A DH30-100ADT200A DT400A Non-Fusible DT600 Non-Fusible DT

Ground Lug Kits30 - 100A DG30-100ADH, DT®200A DG, DH, DT400 - 600A DG, 400-1 200A DH, 400 - 800A DT

Control Pole Kit400 - 600A DG, 30-1 200A DH, 30 - 800A DT

Auxiliary Contact KitsAll Switches (except 30-100A DG) 1NO/1NCAll Switches (except 30-100A DG) 2NO/2NC

Copper Lug Kits30A DH, DT (order one kit for 3 poles)60A DH, DT (order one kit for 3 poles)100A DH, DT (order one kit for 3 poles)200A DH (order one kit for 3 poles)400A DG, DH (order one kit for each pole)600A DG, DH (order one kit for each pole)

Crimp Lug Pad Kit400 - 600A DG, DH (order one kit for 3 poles)800A DH (order one kit for each pole)400 - 800A Neutral DG, DH (order one kit per switch)

Fuse Puller Kits30 - 60A DH (order one kit for 3 poles)30 - 60A DH (4 pole switch only)100A DH (order one kit for 3 poles)200A DH (order one kit for 3 poles)

"J" Fuse Adapter Kits60A 240V DH (order one kit for 3 poles)60A 600V DH (order one kit for 3 poles)400A 600V DT (order one kit for 6 poles)600A 240-600V DH only (order one kit for each pole)

"R" Fuse Adapter Kits (order one kit for 3 poles)30A DG100A DG30A240VDH, DT30A 600V DH, DT, 60A 240V DH, DT, 60A DG60A 600V DH, DT100A240-600VDH, DT200A 240 - 600V DH, DT, 200A DG400A 240 - 600V DH, 240V DT, 400A DG600A 240 - 600V DH, 240V DT, 600A DG

"T" Fuse Adapter Kits200A 240V DH (order one kit for 3 poles)200A 600V DH (order one kit for 3 poles)400A 240V DG, DH (order one kit for each pole)400A 600V DH (order one kit for each pole)600A 240V DG, DH (order one kit for each pole)600A 600V DH (order one kit for each pole)800A 240V DH (order one kit for each pole)800A 600V DH (order one kit for each pole)

Hookstick Handle

Auxiliary Contacts for30A - 40A 3-pole Rotary Switches (1 NO) ®60A-100A3-pole Rotary Switches (1NO)®30A - 40A 4-pole Rotary Switches (1 NO) ®

CatalogNumber

DG030NBDG100NBDG200NKDH030NKDH100NKDH200NKDS400NKDS600NKDS800NKDT100NKDT200NKDT400NKDT600NK

DG030GBDS100GKDS200GKDS468GK

DS16CP

DS200EK1DS200EK2

DS16CLDS26CLDS36CLDS46CLDS56CLDS66CL

DS56CKDS76CKDS800CNK

DS30FPDS60FPDS100FPDS200FP

DS22JKDS26JKDT400JKDS600JK

DG030RBDG100RBDS12FKDS16FKDS26FKDS36FKDS46FKDS56FKDS66FK

DS426TKDS466TKDS526TKDS566TKDS626TKDS666TKDS726TKDS766TK

DH800HSH

CRAC3CWAC3CRAC4

PriceU.S.S

44.0088.00

129.0059.50

124.00142.00243.00258.00550.0077.50

135.00198.00250.00

16.1016.1030.00

171.00

148.00

203.00242.00

29.0036.5059.00

201.00249.00290.00

332.00149.00431.00

19.5027.0035.7584.00

18.4018.40

389.00135.00

17.1033.2517.1017.1017.1033.2549.5084.0084.00

191.00211.0065.0096.00

105.00109.00113.00132.00

129.00

29.2529.2529.25

DH030NK DS200GK

DS16CP DS200EK1

DS36CL DS56CK

DS30FP DS26JK

DS12FK DS426TK

® Single-pole, double throw, single-break snap action contactsrated at 6A, 250V maximum.

® Ground bar kit is not listed on device publications.

Discount Symbol 22-CD

E:T*M For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.200.01.T.E

Safety Switches & Enclosed Circuit BreakersSafety SwitchesHeavy Duty Double Throw, Fusible, Non-Fusible

Cutler-HammerJanuary 2001

Vol. 1,Ref. No. [0250]

240V AC Heavy Duty Double Throw,

Fusible, Non-Fusible

Specifications

• 30 through 800 amperes,n Horsepower rated.• Suitable for service entrance use

with neutral or ground lug kitinstalled.

• Suitable for use as a manuallyoperated switch per NEC article 702.

•i Fusible and non-fusible.• UL Listed File No. E5239.• For factory modifications refer to

Pages 8-6 through 8-9.

Table 8-41. Fusible

A, A, A,

A, A. A. iy°N

>ON

b© OFF Two Sources\ I

KON

ba OFF Two Loads

fell' ON

DT323FRK Figure 8-8. Typical Fusible Double ThrowSchematic Diagram

AmpereRatingMainandStandby

FuseClassProvision

Maximum Horsepower Ratingswith Time Delay Fuses

1 -Phase AC

240V 480V 600V

3-Phase AC

240V 480V I 600V

DC250V

NEMA 1 EnclosureIndoor

Catalog Number Price U.S. $

NEMA 3R EnclosureRainproof

Catalog Number Price U.S. $

2-Pole — 240V AC — 250V DC

200 H 15 — — 40 DT224FGK 2,635. DT224FRK 3,660.

3-Pole — 240V AC — 250V DC

3060100200400600

HHHHHT

3101515 —

7-1/215306012575

51020405050

DT321FGKDT322FGKDT323FGKDT324FGKDT325FGKDT326FGK

760.1,385.2,255.3,420.8,280.8,710.

DT321FRKDT322FRKDT323FRKDT324FRKDT325FRKDT326FRK

1,000.1,830.2,605.4,445.9,360.

10,350.

Table 8-42. Non-Fusible

AmpereRatingMainandStandby

Maximum Horsepower Ratings

1 -Phase AC

240V 480V 600V

3-Phase AC

240V 480V 600V

DC250V

NEMA 1 EnclosureIndoor

Catalog Number Price U.S. $

NEMA 3R EnclosureRainproof

Catalog Number Price U.S. $

Non-Fusible 2-Pole — 240V AC — 250V DC

3060100200400600

3102015

— —

——

—510204050

DT221UGKDT222UGKDT223UGKDT224UGKDT225UGKDT226UGK

417.665.955.

1,265.3,655.6,160.

®®®DT224URKDT225URK®

1,650.5,620.

Non-Fusible 3-Pole — 240V AC — 250V DC

3060100200400600800

3102015

——

10204060125125125

— —

5102040505050

DT321UGKDT322UGKDT323UGKDT324UGKDT325UGKDT326UGKDT327UGK®®

485.830.

1,225.1,815.5,110.6,910.

10,420.

®®DT323URKDT324URK®®®

1,320.2,300.

® WARNING! Switch is not approved for service entrance.® Field installable neutral kit is not available. If a neutral is required, order the catalog number shown in the table with "—N" suffix.® Contact the Safety Switch Flex Center (1-888-329-9272) for availability of this product.

Discount Symbol 22-CD

F;T« For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.200.01.T.E

January 2001Vol. 1,Ref. No. [0251]

Safety Switches & Enclosed Circuit BreakersSafety Switches

Heavy Duty Double Throw, Fusible, Non-Fusible

600V AC Heavy Duty Double Throw, Fusible, Non-FusibleTable 8-43. Fusible

AmpereRatingMainandStandby

FuseClassProvision

Maximum Horsepower Ratingswith Time Delay Fuses

1 -Phase AC

480V 600V

3-Phase AC

480V 600V

DC

250V

NEMA1EnclosureIndoor

CatalogNumber

PriceU.S. S

NEMA3REnclosureRainproof

CatalogNumber

PriceU.S.S

NEMA 12EnclosureIndustrial Dust-tight

CatalogNumber

PriceU.S.S

NEMA 4XEnclosureCorrosion ResistantStainless Steel

CatalogNumber

PriceU.S.S

3-Pole — 600V AC — 250V DC

3060100200400

HHHHT

7-1/2203050—

10254050—

153060125250

205075150350

——4050

DT361FGKDT362FGKDT363FGKDT364FGKDT365FGK

1,440.1,520.2,585.4,000.8,420.

®©DT363FRKDT364FRKDT365FRK

——

3,215.5,180.9,520.

®®®®®

—————

DT361FWKDT362FWKDT363FWKDT364FWKDT365FWK

3,150.8,330.9,430.

11,620.18,880.

® Contact the Safety Switch Flex Center (1-888-329-9272) for availability of this product.

Table 8-44. Non-Fusible

AmpereRatingMainandStandby

Maximum Horsepower Ratings

1 -Phase AC

480V 600V

3-Phase AC

480V 600V

DC

250V

NEMA 1 EnclosureIndoor

CatalogNumber

PriceU.S. $

NEMA 3R EnclosureRainproof

CatalogNumber

PriceU.S.S

NEMA 12 EnclosureIndustrial Dust-tight

CatalogNumber

PriceU.S.S

NEMA 4X EnclosureCorrosion ResistantStainless Steel

CatalogNumber

PriceU.S.S

2-Pole — 600V AC — 250V DC3060100200400600

7-1/2204050—

10255050—

—————

—————

51020405050

DT261UGKDT262UGKDT263UGKDT264UGK®DT265UGKDT266UGK

500.715.

1,070.1,475.4,590.6,820.

®®®DT264URK®DT265URKDT266URK

———

3,545.7,980.9,950.

—————

—————

_

————

—————

3-Pole — 600V AC — 250V DC

3060100200400600800800

7-1/2203050————

10255050————

205075125250250250250

2050100150350350350350

510204050505050

DT361UGKDT362UGKDT363UGKDT364UGKDT365UGKDT366UGKDT367UGK@®DT367UGK-N

535.810.

1,325.1,945.5,210.7,640.

11,660.12,560.

DT361URKDT362URKDT363URKDT364URKDT365URKDT366URKDT367URK®®DT367URK-N

985.1,360.2,300.4,200.8,410.

10,900.12,880.13,780.

DT361UDK®DT362UDK®DT363UDK®DT364UDK®DT365UDK®®®®

1,055.2,240.2,370.4,355.8,630.

———

DT361UWKDT362UWKDT363UWKDT364UWKDT365UWK®®®

2,070.3,805.5,770.6,960.

15,150.———

4-Poie — 600V AC — 250V DC ®

3060100200400600800

204050———

25505050——

205075125250250250

3060100150350350350

5102040505050

®®®DT464UGKDT465UGKDT466UGKDT467UGK

———

3,380.7,750.

11,200.28,990.

DT461URKDT462URKDT463URKDT464URKDT465URKDT466URKDT467URK

2,440.2,610.3,760.5,970.

10,500.12,920.37,660.

®®®©©®®

——————

®®©®©©©

——————

6-Pole — 600V AC — 250V DC ®

3060100

7-1/22030

2060100

DT661URKDT662URKDT663URK

3,855.4,870.7,320.

® NEMA 12 enclosures (30 - 200 amperes) can be field modified to meet NEMA 3R rainproof requirements when a factory provided drain hole is opened® WARNING! Switch is not approved for service entrance.® Rated 600V DC, 50 hp in addition to ratings shown in table.© Also available in 240V AC catalog number DT325UDK.® Field installable neutral kit is not available. If a neutral is required, order the catalog number shown in the table with "—N" suffix.® Contact the Safety Switch Flex Center (1-888-329-9272) for availability of this product.

Discount Symbol 22-CD