Post on 24-Apr-2018
Section 8 – Reverse Osmosis SystemsCatalog 999701-NP Rev. F (05/17)Effective – 05/01/17
Reverse Osmosis Systems Section 8
Reverse Osmosis Systems
Section 8 – Reverse Osmosis SystemsCatalog 999701-NP Rev. F (05/17)Effective – 05/01/17
Section 8 Reverse Osmosis Systems Table of ContentsReverse Osmosis Systems Specifications And Design DataHVE Series - 2,000 - 10,800 GPD ...................................................................................................8-1MVE Series - 500 - 2,000 GPD .......................................................................................................8-2LVE Series - 250 - 500 GPD ............................................................................................................8-3
Reverse Osmosis Systems ConfigurationsHVE Series – Best – 2,000 To 14,400 GPD Capacity .....................................................................8-4HVE Series – Better – 2,000 To 14,400 GDP Capacity ...................................................................8-5MVE Series – Better – 500 To 2,000 GDP Capacity ......................................................................8-6LVE Series – Better – 250 To 500 GDP Capacity ...........................................................................8-7REVERSE OSMOSIS ATMOSPHERIC DELIVERY SYSTEMS ......................................................8-8
Reverse Osmosis Components Pressure Tank Kits ...........................................................................................................................8-9RO Accessories ...............................................................................................................................8-10
Reverse Osmosis Systems Section 8
Prices subject to change without notice. Specifications subject to change without notice. Orders subject to acceptance by EcoWater Systems, LLC.
Effective 05/01/17 8-1Form No. 999701-NP
Reverse Osmosis Units Specifications and Design Data
ECI HVE Series 2,000 – 14,400 GPD Capacity (1.4 – 10 GPM)
Model Number R1F40 R2F40 R3F40 R4F40 R5F40 R6F40 R8F40
Product Flow (1) (2)
GPM 1.4 2.7 3.9 5.2 6.6 7.5 10
GPD 2,000 3,900 5,600 7,500 9,500 10,800 14,400
Feed Flow (GPM) 2.8 5.4 7.8 10.4 13.2 15 20
Reject Flow (GPM) 1.4 2.7 3.9 5.2 6.6 7.5 10
Recycle Yes Yes Yes Yes Yes Yes Yes
Rejection 98% 98% 98% 98% 98% 98% 98%
Recovery Range 18 – 75% 32 – 75% 42 – 75% 34 – 75% 37 – 75% 42 – 75% 50 – 75%
Membrane Size 4” x 40” 4” x 40” 4” x 40” 4” x 40” 4” x 40” 4” x 40” 4” x 40”
Vessel Size 1M 1M 1M 1M 1M 1M 1M
Array 1 1:1 1:1:1 2:1:1 2:2:1 2:2:1:1 3:3:2
No. of Membranes 1 2 3 4 5 6 8
Prefilter 1 – 10” 1 – 10” 1 – 10” 1 – 20” 1 – 20” 1 – 20” 1 – 20”
Pipe Size In
Feed – Pkg 1 0.75” FNPT 0.75” FNPT 0.75” FNPT 1.0” FNPT 1.0” FNPT 1.0” FNPT 1.0” FNPT
Feed – Pkg 2 0.75” FNPT 0.75” FNPT 0.75” FNPT 1.0” FNPT 1.0” FNPT 1.0” FNPT 1.0” FNPT
Feed – Pkg 3 0.75” FNPT 0.75” FNPT 0.75” FNPT 1.0” FNPT 1.0” FNPT 1.0” FNPT 1.0” FNPT
Product – Pkg 1 0.375” Tube 0.375” Tube 0.375” Tube 0.5” Tube 0.5” Tube 0.5” Tube 0.5” Tube
Product – Pkg 2 0.5” FNPT 0.5” FNPT 0.5” FNPT 1.0” FNPT 1.0” FNPT 1.0” FNPT 1.0” FNPT
Product - Pkg 3 0.75” FNPT 0.75” FNPT 0.75” FNPT 0.75” FNPT 0.75” FNPT 0.75” FNPT 0.75” FNPT
Reject – Pkg 1 0.375” MNPT 0.375” MNPT 0.375” MNPT 0.5” MNPT 0.5” MNPT 0..5” MNPT 0.5” FNPT
Reject – Pkg 2 0.5” FNPT 0.5” FNPT 0.5” FNPT 1.0” FNPT 1.0” FNPT 1.0” FNPT 1.0” FNPT
Reject – Pkg 3 0.5” FNPT 0.5” FNPT 0.5” FNPT 1.0” FNPT 1.0” FNPT 1.0” FNPT 1.0” FNPT
Feed Pressure (psig) 20 – 50 20 – 50 20 – 50 20 – 50 20 – 50 20 – 50 20 – 50
Pump HP 3/4 3/4 3/4 2 2 2 2
Power 220V/60Hz/1 ph
220V/60Hz/1 ph
220V/60Hz/1 ph
220V/60Hz/1 ph
220V/60Hz/1 ph
220V/60Hz/1 ph
220V/60Hz/1 ph
Amps 8 8 8 17 17 17 17
Dimensions (LxDxH) (3) 26” x 16” x 54”
26” x 16” x 54”
26” x 16” x 54”
26” x 16” x 54”
38” x 16” x 54”
38” x 16” x 54”
38” x 21” x 54”
Notes:(1) Based upon feed water: SDI<3, free chlorine 0.0 mg/l maximum, pH 2-11 and temperature 77O F.(2) System flows are design parameters.(3) All dimensions approximate. Additional space required for maintenance.
Section 8 Reverse Osmosis Systems
Prices subject to change without notice. Specifications subject to change without notice. Orders subject to acceptance by EcoWater Systems, LLC.
Effective 05/01/17 8-2Form No. 999701-NP
Reverse Osmosis Units Specifications and Design Data
ECI MVE Series 500 – 2,000 GPD Capacity
Model Number R2E12 R4E12 R4E12P
Product Flow (1) (2)
GPM .35 .7 1.4
GPD 500 1,000 2,000
Feed Flow (GPM) .7 1.4 2.8
Reject Flow (GPM) .35 .7 1.4
Recycle No No Yes
Rejection 95% 95% 95%
Max Recovery 75% 75% 75%
Membrane Size 2” x 12” 3” x 12” 3” x 12”
Vessel Size 3” x 12” 3” x 12” 3” x 12”
No. of Membranes 2 4 4
Prefilter GAC/Sediment GAC/Sediment GAC/Sediment
Pipe Size In
Feed 1/2” NPT 1/2” NPT 1/2” NPT
Product 3/8” 3/8” 3/8”
Reject 3/8” 3/8” 3/8”
Feed Pressure (psig) 40 - 125 PSI
Pump HP - - 1/3
Power 110V, 1 ph
Amps 4 4
Dimensions (LxDxH) (3) 21” x 12.5” x 30.9”
Notes:(1) Based upon feed water: SDI<3, free chlorine 0.0 mg/l maximum, pH 3-11 and temperature 77O F.(2) System flows are design parameters.(3) All dimensions approximate. Additional 18” space required around system for maintenance.
Reverse Osmosis Systems Section 8
Prices subject to change without notice. Specifications subject to change without notice. Orders subject to acceptance by EcoWater Systems, LLC.
Effective 05/01/17 8-3Form No. 999701-NP
Reverse Osmosis Units Specifications and Design Data
ECI LVE Series 250 – 500 GPD Capacity
Model Number R1E12 R2E12
Product Flow (1) (2)
GPM .175 .35
GPD 250 500
Feed Flow (GPM) .35 .7
Reject Flow (GPM) .175 .35
Rejection 95% 95%
Max Recovery 75% 75%
Membrane Size 3” x 12” 3” x 12”
Vessel Size 3” x 12” 3” x 12”
No. of Membranes 1 2
Prefilter GAC/Sediment GAC/Sediment
Pipe Size In
Feed 3/8” 3/8”
Product 3/8” 3/8”
Reject 3/8” 3/8”
Feed Pressure (psig) 40 - 125 PSI
Power 24VDC
Watts 25
Dimensions (LxDxH) (3) 14” x 6.06” x 22.38”
Notes:(1) Based upon feed water: SDI<3, free chlorine 0.0 mg/l maximum, pH 3-11 and temperature 77O F.(2) System flows are design parameters.(3) All dimensions approximate. Additional 18” space required around system for maintenance.(4) Membrane performance measured @ 70 PSI, 77oF, 40% recovery 250ppm NaCL
Section 8 Reverse Osmosis Systems
Prices subject to change without notice. Specifications subject to change without notice. Orders subject to acceptance by EcoWater Systems, LLC.
Effective 05/01/17 8-4Form No. 999701-NP
R4F40-BEST
Reverse Osmosis Systems – HVE Series2,000 to 14,400 GPD Capacity – Best
Features:= 4” x 40” low-energy TFC membranes.= Smooth, quiet operating stainless steel, multi-stage centrifugal pumps with
plastic impellers.= 3/4 or 2 HP 230/60 Hz/1 pH motors providing up to 185 PSI pressure (1” inlet)
with 5-micron filter.= Single power connection for all controls, switches, and solenoid valves.= Stainless steel membrane housings.= Stainless steel solenoid valves.= Heavy-duty, powder coated steel frame for durability and rust resistance.= Pretreatment lockout.= Low level connections .= Low-pressure protection.= Auto re-start after shutdown.= Waste recycle.= Product and waste flow meter.= Product TDS meter.= All systems are fully tested and shipped fully assembled.
Package Options:= Auto flush.= Stainless steel frame.
Nominal Capacity
GPD
Model Number
Part Number
MembranesNo. & Size HP Ship
Wt. Lbs.
2,000 R1F40-BEST 13000341 1 – 4 x 40 3/4 195
3,900 R2F40-BEST 13000342 2 – 4 x 40 3/4 220
5,600 R3F40-BEST 13000343 3 – 4 x 40 3/4 245
7,500 R4F40-BEST 13000344 4 – 4 x 40 2 275
9,500 R5F40-BEST 13000345 5 – 4 x 40 2 300
10,800 R6F40-BEST 13000346 6 – 4 x 40 2 325
14,400 R8F40-BEST 13000348 8 – 4 x 40 2 350
Reverse Osmosis Systems Section 8
Prices subject to change without notice. Specifications subject to change without notice. Orders subject to acceptance by EcoWater Systems, LLC.
Effective 05/01/17 8-5Form No. 999701-NP
R2F40-BETTER
Reverse Osmosis Systems – HVE Series2,000 to 14,400 GPD Capacity – Better
Standard Features:= 4” x 40” low-energy TFC membranes.= Smooth, quiet operating stainless steel, multi-stage centrifugal pumps with plastic
impellers.= 3/4 or 2 HP 230/60 Hz/1 pH motors providing up to 185 PSI pressure (1” inlet)
with 5-micron filter.= Single power connection for all controls, switches, and solenoid valves.= Stainless steel membrane housings.= Stainless steel solenoid valves.= Heavy-duty, powder coated steel frame for durability and rust resistance.= Pretreatment lockout.= Low level connections.= Low-pressure protection.= Auto re-start after shutdown.= Waste recycle.= Product and waste flow meter. = All systems are fully tested and shipped fully assembled.
Package Options:= Auto flush.= Stainless Steel frame.
Nominal Capacity
GPD
Model Number
Part Number
MembranesNo. & Size HP Ship
Wt. Lbs.
2,000 R1F40-BETTER 13000331 1 – 4 x 40 3/4 195
3,900 R2F40-BETTER 13000332 2 – 4 x 40 3/4 220
5,600 R3F40-BETTER 13000333 3 – 4 x 40 3/4 245
7,500 R4F40-BETTER 13000334 4 – 4 x 40 2 275
9,500 R5F40-BETTER 13000335 5 – 4 x 40 2 300
10,800 R6F40-BETTER 13000336 6 – 4 x 40 2 325
14,400 R8F40-BETTER 13000338 8 – 4 x 40 2 350
Section 8 Reverse Osmosis Systems
Prices subject to change without notice. Specifications subject to change without notice. Orders subject to acceptance by EcoWater Systems, LLC.
Effective 05/01/17 8-6Form No. 999701-NP
R4E12P-BETTER
Reverse Osmosis Systems – MVE Series500 to 2,000 GPD Capacity – Better
Features:= Wall mount or floor/shelf mount.= Zero clearance required on bottom and sides.= All components can be serviced from front or top of unit.= Pretreatment lockout.= 3” x 12” XLP low pressure membranes.= 1/3 HP 110/60 Hz/1-phase motors providing up to 125 PSI pressure.= Easy to operate filter in, filter out, pump and product pressure gauges.= Single power connection for all controls, switches, and solenoid valves.= Carbon filter and 5-micron sediment filter.= Smooth, quiet operating, brass vane-type pump (2,000 GPD unit only).= Standard plumbing connections - 1/2” Inlet, 3/8” permeate and drain
connections.= Stainless steel solenoid valves.= Heavy-duty, powder coated steel cabinet for durability and rust resistance.= All systems are fully tested and shipped fully assembled.
Nominal Capacity
GPD
Model Number
Part Number
MembranesNo. & Size
(vessel)HP Ship
Wt. Lbs.
500 MVE-R2E12-BETTER 13000432 2 – 3 x 12 N/A 75
1,000 MVE-R4E12-BETTER 13000434 4 – 3 x12 N/A 80
2,000 MVE-R4E12P-BETTER 13000444 4 – 3 x 12 1/3 100
Reverse Osmosis Systems Section 8
Prices subject to change without notice. Specifications subject to change without notice. Orders subject to acceptance by EcoWater Systems, LLC.
Effective 05/01/17 8-7Form No. 999701-NP
Reverse Osmosis Systems – LVE Series250 to 500 GPD Capacity – Better
Features:= Compact design - Wall mounted.= Pretreatment lockout - Disables RO production during regeneration.= Single power connection - For all controls, switches and solenoid valves.= Simple, easy to read gauges - Filter in, filter out, and product pressure gauges.= High flow, low-pressure XLP membrane - 98.5% maximum TDS rejection.
Stands up to the most rugged of feed water conditions.= Carbon and sediment filter included - Provides basic pretreatment, de-
chlorination and sediment removal down to 5 microns.= Standard plumbing connection - Uses 3/8” inlet, 3/8” permeate and drain
connections.= Heavy duty, powder-coated steel cabinet for durability and rust resistance.
Nominal Capacity
GPD
Model Number
Part Number
MembranesNo. & Size
(vessel)HP Ship
Wt. Lbs.
250 LVE-R1E12-BETTER 13000531 1 – 3 x12 N/A 75
500 LVE-R2E12-BETTER 13000532 2 – 3 x 12 N/A 80
R2E12-BETTER
Section 8 Reverse Osmosis Systems
Prices subject to change without notice. Specifications subject to change without notice. Orders subject to acceptance by EcoWater Systems, LLC.
Effective 05/01/17 8-8Form No. 999701-NP
Reverse Osmosis Atmospheric Delivery SystemFeatures:= Designed for easy transportation, installation and service – storage tank
designed to fit through most doorways.= Sealed tank with Fact® filter – ensures no air contaminant pollutes the water in
the tank.= Float for RO control, installed.= Float for low level pump protection, installed – protects pump from running
without water.= Compact Grundfos MQ series pump – easy to operate, low-noise and includes a
dry-running protection.= UV light, installed – lamp shipped separately.= Outlet pressure gauge, sample valve and check valve, installed – for easier
installation and service.= Quick plug in electrical connections for:
- Float switches- Pump- Optional automatic bypass if tank reaches low level
= Electrical requirements - 120V, 15 AMP.
Nominal Capacity
Model Number
Part Number Installation Size Ship
Wt. Lbs.
300 ROAD 321 17001021 30”x96”x60” 210
500 ROAD 521 17001023 32”x109”x90” 280
ROAD 321
Reverse Osmosis Systems Section 8
Prices subject to change without notice. Specifications subject to change without notice. Orders subject to acceptance by EcoWater Systems, LLC.
Effective 05/01/17 8-9Form No. 999701-NP
Pressure Tank KitsPressure Tank Package, PSC-48
Description Model NumberPressure Tank Package, PSC-48 17001011Includes:Pressure Tank, 21”x44” 299059Pressure Switch 236052Pressure Gauge, 0-100 PSI 236025Check Valve, 1” Spring Check 203001Ball Valve, 1” SCH80 PVC Union 212002Bushing, PVC 1.25”x1” TxT 219022Instruction Sheet 999630
Pressure Tank Package, PSC-80Description Model Number
Pressure Tank Package, PSC-80 17001013Includes:Pressure Tank, 21”x66” 299067Pressure Switch 236052Pressure Gauge, 0-100 PSI 236025Check Valve, 1” Spring Check 203001Ball Valve, 1” SCH80 PVC Union 212002Bushing, PVC 1.25”x1” TxT 219022Instruction Sheet 999630
Pressure Tank Package, PSC-119Description Model Number
Pressure Tank Package, PSC-119 17001015Includes:Pressure Tank, 24”x76” 299068Pressure Switch 236052Pressure Gauge, 0-100 PSI 236025Check Valve, 1” Spring Check 203001Ball Valve, 1” SCH80 PVC Union 212002Bushing, PVC 1.25”x1” TxT 219022Instruction Sheet 999630
Section 8 Reverse Osmosis Systems
Prices subject to change without notice. Specifications subject to change without notice. Orders subject to acceptance by EcoWater Systems, LLC.
Effective 05/01/17 8-10Form No. 999701-NP
Reverse Osmosis Accessories
Description Model NumberPressure Tank, 20”x40” 35 Gal. Nominal 299059Pressure Tank, 24”x46” 60 Gal. Nominal 299067Pressure Tank, 24”x60” 119 Gal. Nominal 299068Storage Tank, 300 Gal. Doorway w 1.25” Lower Fitting 417031Storage Tank, 500 Gal. Doorway w 1.25” Lower Fitting 417033NC Pressure Switch, 15-80 PSI NC 236052Float Switch, RO Shut Off with Open Wires - SPDT 653048Float Switch, RO Shut Off with 110V Plug - RO Shut-off 653151Float Switch, RO Shut Off with 220V - RO Shut-off 653152Check Valve, 1” Spring Check 203001Ball Valve, 1” SCH80 PVC Union 212002Pressure Gauge, 0-100 PSI - Rear Center 1/4 NPT 236025Cover, MQ3-45 RO Delivery Pump 201130Pump, MQ3-45 RO Delivery 110V 20 GPM 201134Pump, MQ3-45 RO Delivery 220V 20 GPM 201135Bulkhead Fitting, .5” for RO Fill 405040Bulkhead Fitting, .75” for RO Fill 405041Bulkhead Fitting, 1” for RO Fill 405042Blending Kit HVE, w/Flow Meter 652235Blending Kit MVE w/Flow Meter 652236HVE/MVE - 5 Micron Sediment Filter 235024MVE - Carbon Filter 235037MVE/LVE - Membrane & Housing Kit 651030HVE - Autoflush Kit 652228LVE - RO Pump Kit 652229RO Membrane - Low Energy - 4x40 650188