Post on 11-Mar-2020
GVM66AAPRODUCT SPECIFICATION
OPERATION:
Application: L.B.P. Max. Ambient Temp: 43°CRefrigerant: R134a
(1) Max. Steady Discharge Temp: 120°COperation: Capillary (1,2) Max. Peak Discharge Temp: 135°C
Cooling: Static Max. Steady Condensing Temp: 60°C(2) Max. Peak Condensing Temp: 70°C
Max. Winding Temp: 130°C
Max. Impurities: 30 mgMax.Total Compressor Water Content: 100 mg
COMPRESSOR:
Displacement: 7.00 cc Oil Type: Ester(4) Viscosity: 15 cSt
Suction Muffler: Semi-direct
(3) Net Wt: 7.7 kgCase Size: 2 (h = 169.5 mm)Oil Charge: 180 cc
ELECTRICAL:
Power Supply: 220 - 240V Motor Type: RSIRVoltage Limits: 187 - 264V
Frequency: 50 Hz Locked Rotor Current: 13.5 / 6.4 A**Phase: 1 ph
Main Winding Resistance at 25°C: 13.0 ΩStart Winding Resistance at 25°C: 14.8 Ω
** Maximum current / Measured after 4 seconds
For rated performance,
(1) Measured 5cm. from the shell with insulated thermocouples the suction line must be connected to the stub
(2) For transient conditions during 'Pull Down' marked 'AS' on the attached drawing.
(3) Net weight is with oil but without electrics
(4) Measured at 40°C
AE 0389.0 Jun '07 Page 1 ACC reserves the right to change the data without prior notice
h
GVM66AAPRODUCT SPECIFICATION
ELECTRICAL COMPONENTS:
ECC Starting Device: K 100-xx -xx Protector short code
Starting Device: PTC- 8100(1) Starting Device: PTC - 7100DT
PTC Resistance: 14 Ω
PROTECTORS: BDG ¾Type AE 72 FU x
Open °C 115 - 125 °CClose °C 71 - 53 °C
U.T.C 2.10 A 70 °CTime Check Current 8.60 A
Max. Current 17.0 ACode (if any) FP
WANBAOType B88 110 xx
Open °C 105 - 115 °CClose °C 70 - 52 °C
U.T.C 2,22 A 70 °CTime Check Current 8,8 A
Max. Current 18,0 ACode (if any) M9
Alt. protectors: AF 72 FU xCode (if any) DT
BDG 'x' Codes: 6 for terminal boards Mod.89,90
8 for terminal board Mod.91
4 for UH protector with 6.3mm fast-on
5 for UH protector with M3.5 screw
AE 0389.0 Jun '07 Page 2 ACC reserves the right to change the data without prior notice
GVM66AAPRODUCT SPECIFICATION
PERFORMANCE: (Graphs are at ASHRAE conditions) 220V 50Hz
60°C COND.
55°C TEMP.
50°C
45°C
40°C
60°C COND.
55°C TEMP.
50°C
45°C
40°C
40°C TEMP.
45°C TEMP.
50°C
55°C
60°C
40°C COND.
45°C TEMP.
50°C
55°C
60°C
Evaporating Temperature °C -30 -25 -23,3 -20 -15 -10
ASHRAE: Capacity W 115 162 181 220 288 366C.o.P. W / W 0,99 1,16 1,22 1,34 1,52 1,69
CECOMAF: Capacity W 94 133 180 235 298C.o.P. W / W 0,81 0,95 1,10 1,24 1,38
Input Power W 116 140 148 164 190 216Current A 0,96 1,04 1,07 1,12 1,21 1,29
AE 0389.0 Jun '07 Page 3 ACC reserves the right to change the data without prior notice
105
135
165
195
225
255
285
315
345
375
405
-35 -30 -25 -20 -15 -10 -5Evaporating Temperature (°C)
CapacityWatts
0,90
0,98
1,06
1,14
1,22
1,30
1,38Amps
110125140155170185200215230
InputWatts
0,90
1,10
1,30
1,50
1,70
1,90
2,10C.o.P.
Test Conditions:Condensing Temp:Liquid Temp:Gas Return Temp:Ambient Temp:
CECOMAF55°C55°C32°C32°C
ASHRAE55°C32°C32°C32°C
GVM66AAPRODUCT SPECIFICATION
AE 0389.0 Jun '07 Page 4 ACC reserves the right to change the data without prior notice
Upright
Tubes Down
Electrics Up
Recommended Transport Positions when fitted into
appliances
Appliance,Lights etc.
Circuit Diagram for Mod.90 Terminal Board
Wire Connection
Thermostat
Fast-onconnectors
L
1
N
N
L
MotorProtector
PTCRelay
Run Capacitorwhere applicable
E
S
5th Optional N L
N
EL
Circuit Diagram for ECC Terminal Board Frontal Version
1
MotorProtector
PTC
S
Appliance,Lights etc.
Thermostat
Run Capacitorwhere applicable
x = 24 or 26 or 28.5mmy = 9mm or 10.3mmOther sizes available1. Rubber grommet2. Sleeve3. Washer4. Steel pin5. Clip
Mounting Accessories
y
x
1
2
y
x
1
45 3
ELECTRICAL CHARACTERISTICS
PRODUCTION DATECompressor Label
APPROVALSMANUFACTURER VERSION
CHECK DIGIT
SERIAL NUMBER
BAR CODE
REFRIGERANT
MODELLOGO
< SUCTION
ELECTRICAL CHARACTERISTICS
PRODUCTION DATECompressor Label
APPROVALSMANUFACTURER VERSION
CHECK DIGIT
SERIAL NUMBER
BAR CODE
REFRIGERANT
MODELLOGO
< SUCTION