Post on 30-Jun-2018
1
With the complexity of most engine systems today and the hundreds of different applications on the market, it is important to understand the requirements and product options. PowerHalt offers a broad range of products and systems that range from basic manual pull cable systems to fully automatic auto reset systems. These come with an array of mounting installation kits, components and control options for most industry applications.
BEFORE YOU ORDER
Get to know PowerHalt's product options and what is best suited for your application.
Read our Diesel Engine Safety Overview.
Review our System Selection Guide.
ORDERING MADE EASY
OPTION A ORDERING A POWERHALT KITLook through our PowerHalt Kit Application Guide to see whether a kit is available for your application.
OPTION B ORDERING WITH OUR CUSTOM KIT SELECTION GUIDE If an application is not available in the Application Guide, please refer to the Custom Kit Selection Guide to order your kit from our menu style system.
Custom KitA Determine your valve size (PH1, PH2 & PH3)B Choose an actuation method (PH2 & PH3 only):
▪ Pull cable ▪ Electric ▪ Pneumatic ▪ Combination
C Specify the desired control option: ▪ Automatic ▪ Manual (PH2 & PH3 only)D Select a mounting group (PH1, PH2 & PH3)E Pick the components for your application (as applicable) (PH1, PH2 & PH3)
▪ Pull cable ▪ Magnetic pick-up size ▪ Harnesses
OPTION C NEW PRODUCT DEVELOPMENTIf your application is new and not available with us, please � ll out the Product Development Sheet and send it to a PowerHalt customer service representative at: insidesales@pacbrake.com
CONFIRMATION OF YOUR ORDER
Your dealer or PowerHalt representative will con� rm the order and application details to ensure the system selected in best suited to your needs.
1
2
3
POWERHALT–FOR VALVING SOLUTIONS AS VARIED AS OUR CUSTOMERS800.663.0096 / www.powerhalt.com
PACBRAKE PRODUCT CATALOGUE
How to Order Your PowerHalt
PH
2P
H 3
CO
MP
ON
EN
TS
WA
RR
AN
TY
PH
1
2
For the most UP-TO-DATE APPLICATION GUIDES visit our website: PowerHalt.com
APPLICATION GUIDES
800.663.0096 / www.powerhalt.com
PH1 POWERHALT SHUT-OFF VALVES
MAKE / MODEL SIZE CONTROL/ RESET ACTUATION KIT # INSTALL
MANUALUNIVERSAL APPLICATIONGeneric 1.75" Manual Pull Cable* C50148 6390
Generic 2.0" Manual Pull Cable* C50145 6390
Generic 2.25" Manual Pull Cable* C50146 6390
Generic 2.5" Manual Pull Cable* C50147 6390
* NOTE: A mounting group & pull cable are not included. See charts below to add correct sizes for specific applications.
PH1 POWERHALT SHUT-OFF VALVE ACCESSORIES
ACCESSORY MAKE / MODEL SIZE PART #PULL CABLE (MUST ADD TO PH1 VALVE KIT FOR A COMPLETE SYSTEM)
Pull Cable Universal 2 ft C50018
Pull Cable Universal 4 ft C50022
Pull Cable Universal 6 ft C50026
Pull Cable Universal 8 ft C50030
Pull Cable Universal 10 ft C50035
MOUNTING GROUP (MUST ADD TO PH1 VALVE KIT FOR A COMPLETE SYSTEM)
Mounting Group Universal 1.75" C50117
Mounting Group Universal 2.0" C50118
Mounting Group Universal 2.25" C50119
Mounting Group Universal 2.5" C50116
L6411_REV1_28.October.16
PH
2P
H 3
CO
MP
ON
EN
TS
WA
RR
AN
TY
PH
1P
H 1
3
For the most UP-TO-DATE APPLICATION GUIDES visit our website: PowerHalt.com
800.663.0096 / www.powerhalt.com
APPLICATION GUIDES
PH2 POWERHALT SHUT-OFF VALVES*
MAKE / MODEL SIZE CONTROL/ RESET ACTUATION KIT # INSTALL
MANUALCLASS 3-5 PICK-UP TRUCK / CHASSIS CAB TRUCKS DODGE1994-2002 Dodge Ram with a 5.9L Cummins Diesel Engine N/A Manual / Manual N/A C50200 6209
1994-2002 Dodge Ram with a 5.9L Cummins Diesel Engine N/A Auto / Manual N/A C50200A 6284
2003-2007 Dodge Ram with a 5.9L Cummins Diesel Engine N/A Manual / Manual N/A C50203 6281
2007.5-2009 Dodge Ram with a 6.7L Cummins Diesel Engine N/A Manual / Manual N/A C50201 6265
2007.5-2009 Dodge Ram with a 6.7L Cummins Diesel Engine N/A Auto / Manual N/A C50201A 6283
2010-2012 Dodge Ram with a6.7L Cummins Diesel Engine
N/A Manual / Manual N/A C50202 6265
2010-2012 Dodge Ram with a6.7L Cummins Diesel Engine
N/A Auto / Manual N/A C50202A 6283
2013-2016 Dodge Ram with a 6.7L Cummins Diesel Engine N/A Manual / Manual N/A C50204 6266
2013-2016 Dodge Ram with a 6.7L Cummins Diesel Engine N/A Auto / Manual N/A C50204A 6279
FORD2011-2016 Ford with a 6.7L Powerstroke Diesel Engine N/A Manual / Manual N/A C50207 6278
2011-2016 Ford with a 6.7L Powerstroke Diesel Engine N/A Auto / Manual N/A C50207A 6285
GM / CHEVROLET2011-2016 GMC / CHEV with a 6.6L (LML) Duramax Diesel Engine N/A Manual / Manual N/A C50210 6296
2011-2016 GMC / CHEV with a 6.6L (LML) Duramax Diesel Engine N/A Auto / Manual N/A C50210A 6297
* Note: All PH2 kits are 12 VDC unless otherwise stated
PH
2P
H 3
CO
MP
ON
EN
TS
WA
RR
AN
TY
PH
1P
H 2
4
For the most UP-TO-DATE APPLICATION GUIDES visit our website: PowerHalt.com
800.663.0096 / www.powerhalt.com
APPLICATION GUIDES
PH2 POWERHALT SHUT-OFF VALVES*
MAKE / MODEL SIZE CONTROL/ RESET ACTUATION KIT # INSTALL
MANUALCLASS 6 - 8 COMMERCIAL HEAVY DUTY TRUCKSAny Commercial Truck
Generic Manual / Manual Pull CableContact
Pacbrake6351
Any Commercial TruckGeneric Manual / Manual Pneumatic
Contact Pacbrake
6252
Any Commercial Truck 3.0" Manual / Manual Electric C50218 6274
Any Commercial Truck (24 VDC) 3.0" Manual / Manual Electric C50218-24 6274
Any Commercial Truck 3.0" Auto / Manual Electric C50218A 6275
Any Commercial Truck (24 VDC) 3.0" Auto / Manual Electric C50218A-24 6275
Any Commercial Truck 3.5" Manual / Manual Electric C50217 6274
Any Commercial Truck 3.5" Auto / Manual Electric C50217A 6275
Any Commercial Truck 4.0" Manual / Manual Electric C50209 6274
Any Commercial Truck (24 VDC) 4.0" Manual / Manual Electric C50209-24 6274
Any Commercial Truck 4.0" Auto / Manual Electric C50209A 6275
Any Commercial Truck (24 VDC) 4.0" Auto / Manual Electric C50209A-24 6275
Commercial Truck with a Detroit DD13, 15 or 16 Engine
4.0" Manual / Manual Electric C50205 6290
Commercial Truck with a Detroit DD13, 15 or 16 Engine
4.0" Auto / Manual Electric C50205A 6289
Kenworth T800 with an ISX Diesel Engine
4.0" Manual / Manual Electric C50219 6311
Kenworth T800 with an ISX Diesel Engine
4.0" Auto / Manual Electric C50219A 6312
Any Commercial Truck 5.0" Auto / Manual Electric C50247A 6275
Any Commercial Truck (24 VDC) 5.0" Auto / Manual Electric C50247A-24 6275
Any Commercial Truck 5.0" Manual / Manual Electric C50247 6274
Any Commercial Truck (24 VDC) 5.0" Manual / Manual Electric C50247-24 6274
* Note: All PH2 kits are 12 VDC unless otherwise stated
PH
2P
H 3
CO
MP
ON
EN
TS
WA
RR
AN
TY
PH
1P
H 2
5
For the most UP-TO-DATE APPLICATION GUIDES visit our website: PowerHalt.com
800.663.0096 / www.powerhalt.com
APPLICATION GUIDES
REV8_23.March.2016
PH2 POWERHALT SHUT-OFF VALVES*
MAKE / MODEL SIZE CONTROL/ RESET ACTUATION KIT # INSTALL
MANUALSTATIONARY EQUIPMENTUNIVERSAL APPLICATION Generic
2.8"- 5.0" Auto / ManualElectric – Double
Pull CableContact
Pacbrake6336
Generic2.8"- 5.0" Manual / Manual Pull Cable
Contact Pacbrake
6351
Generic 4.0" Manual / Manual Electric C50209 6274
Generic (24 VDC) 4.0" Manual / Manual Electric C50209-24 6274
Generic 4.0" Auto / Manual Electric C50209A 6275
Generic (24 VDC) 4.0" Auto / Manual Electric C50209A-24 6275
Generic 5.0" Auto / Manual Electric C50247A 6275
Generic (24 VDC) 5.0" Auto / Manual Electric C50247A-24 6275
Generic 5.0" Manual / Manual Electric C50247 6274
Generic (24 VDC) 5.0" Manual / Manual Electric C50247-24 6274
GENERATORSCummins / DS-GA A-E / QSB7 3.0" Auto / Manual Electric – Micro Switch C50220A 6320
Cummins / C60D6R / QSB5 Cummins / C80D6R / QSB5 Cummins / 100D6R / QSB
3.0" Auto / Manual Electrical – Micro Switch C50227A 6333
Cummins / DSFAA-35 kw / DSFAB-40kw / DS-FAC-50 kw / DSFAD-60 kw / DSFAE-80 kw
3.0" Auto / Manual Electrical – Micro Switch C50231A 6375
Cummins / C300 D6R /QSM 4.0" Auto / Manual Electric – Micro Switch C50232A 6337
Cummins / DFEG (350) / FEH (400) / DFEJ (450) / DFEK (500) (24 VDC)
5.0" Auto / Manual Electrical – Micro Switch C50237A 6378
Generic 5.0" Auto / Manual Electric C50247A 6275
Generic (24 VDC) 5.0" Auto / Manual Electric C50247A-24 6275
Generic 5.0" Manual / Manual Electric C50247 6274
Generic (24 VDC) 5.0" Manual / Manual Electric C50247-24 6274
* Note: All PH2 kits are 12 VDC unless otherwise stated
PH
2P
H 3
CO
MP
ON
EN
TS
WA
RR
AN
TY
PH
1P
H 2
6
For the most UP-TO-DATE APPLICATION GUIDES visit our website: PowerHalt.com
800.663.0096 / www.powerhalt.com
APPLICATION GUIDES
PH3 POWERHALT SHUT-OFF VALVES
DESCRIPTION SIZE CONTROL/ RESET ACTUATION KIT # INSTALL
MANUALUNIVERSAL KITS (COMMERCIAL TRUCKS / STATIONARY EQUIPMENT)
AutomaticMAG 3/8" WITH 5' HARNESS 1.75" Auto / Auto Reset Electric C50224A 6325
AutomaticMAG 3/8" WITH 10' HARNESS 1.75" Auto / Auto Reset Electric C50224A-10 6325
Manual5' HARNESS WITH MEMBRANE SWITCH 1.75" Manual / Auto Reset Electric C50224 6413
Manual10' HARNESS WITH MEMBRANE SWITCH 1.75" Manual / Auto Reset Electric C50224-10 6413
Manual5' HARNESS WITH TOGGLE SWITCH 1.75" Manual / Auto Reset Electric C50224T 6412
Manual10' HARNESS WITH TOGGLE SWITCH 1.75" Manual / Auto Reset Electric C50224T-10 6412
AutomaticMAG 3/8" WITH 5' HARNESS 2.0" Auto / Auto Reset Electric C50225A 6325
Automatic MAG 3/8" WITH 10' HARNESS 2.0" Auto / Auto Reset Electric C50225A-10 6325
Manual5' HARNESS WITH MEMBRANE SWITCH 2.0" Manual / Auto Reset Electric C50225 6413
Manual10' HARNESS WITH MEMBRANE SWITCH 2.0" Manual / Auto Reset Electric C50225-10 6413
Manual5' HARNESS WITH TOGGLE SWITCH 2.0" Manual / Auto Reset Electric C50225T 6412
Manual10' HARNESS WITH TOGGLE SWITCH 2.0" Manual / Auto Reset Electric C50225T-10 6412
AutomaticMAG 3/8" WITH 5' HARNESS 2.25" Auto / Auto Reset Electric C50252A 6325
AutomaticMAG 3/8" WITH 10' HARNESS 2.25" Auto / Auto Reset Electric C50252A-10 6325
Manual5' HARNESS WITH MEMBRANE SWITCH 2.25" Manual / Auto Reset Electric C50252 6413
Manual10' HARNESS WITH MEMBRANE SWITCH 2.25" Manual / Auto Reset Electric C50252-10 6413
Manual5' HARNESS WITH TOGGLE SWITCH 2.25" Manual / Auto Reset Electric C50252T 6412
Manual10' HARNESS WITH TOGGLE SWITCH 2.25" Manual / Auto Reset Electric C50252T-10 6412
Automatic MAG 3/8" WITH 5' HARNESS 2.5" Auto / Auto Reset Electric C50243A 6325
AutomaticMAG 3/8" WITH 10' HARNESS 2.5" Auto / Auto Reset Electric C50243A-10 6325
Manual5' HARNESS WITH MEMBRANE SWITCH 2.5" Manual / Auto Reset Electric C50243 6413
Manual10' HARNESS WITH MEMBRANE SWITCH 2.5" Manual / Auto Reset Electric C50243-10 6413
Manual5' HARNESS WITH TOGGLE SWITCH 2.5" Manual / Auto Reset Electric C50243T 6412
Manual10' HARNESS WITH TOGGLE SWITCH 2.5" Manual / Auto Reset Electric C50243T-10 6412
PH
2P
H 3
CO
MP
ON
EN
TS
WA
RR
AN
TY
PH
1P
H 3
7
For the most UP-TO-DATE APPLICATION GUIDES visit our website: PowerHalt.com
800.663.0096 / www.powerhalt.com
APPLICATION GUIDES
PH3 POWERHALT SHUT-OFF VALVES
DESCRIPTION SIZE CONTROL/ RESET ACTUATION KIT # INSTALL
MANUALUNIVERSAL KITS (COMMERCIAL TRUCKS / STATIONARY EQUIPMENT)
AutomaticMAG 3/8" WITH 5' HARNESS 2.75" Auto / Auto Reset Electric C50244A 6325
AutomaticMAG 3/8" WITH 10' HARNESS 2.75" Auto / Auto Reset Electric C50244A-10 6325
Manual5' HARNESS WITH MEMBRANE SWITCH 2.75" Manual / Auto Reset Electric C50244 6413
Manual10' HARNESS WITH MEMBRANE SWITCH 2.75" Manual / Auto Reset Electric C50244-10 6413
Manual5' HARNESS WITH TOGGLE SWITCH 2.75" Manual / Auto Reset Electric C50244T 6412
Manual10' HARNESS WITH TOGGLE SWITCH 2.75" Manual / Auto Reset Electric C50244T-10 6412
AutomaticMAG 3/4" WITH 5' HARNESS 3.0" Auto / Auto Reset Electric C50226A 6325
AutomaticMAG 3/4" WITH 10' HARNESS 3.0" Auto / Auto Reset Electric C50226A-10 6334
Manual5' HARNESS WITH MEMBRANE SWITCH 3.0" Manual / Auto Reset Electric C50226 6413
Manual10' HARNESS WITH MEMBRANE SWITCH 3.0" Manual / Auto Reset Electric C50226-10 6413
Manual5' HARNESS WITH TOGGLE SWITCH 3.0" Manual / Auto Reset Electric C50226T 6412
Manual10' HARNESS WITH TOGGLE SWITCH 3.0" Manual / Auto Reset Electric C50226T-10 6412
AutomaticMAG 3/4" WITH 5' HARNESS 3.5" Auto / Auto Reset Electric C50256A 6325
AutomaticMAG 3/4" WITH 10' HARNESS 3.5" Auto / Auto Reset Electric C50256A-10 6334
Manual5' HARNESS WITH MEMBRANE SWITCH 3.5" Manual / Auto Reset Electric C50256 6413
Manual10' HARNESS WITH MEMBRANE SWITCH 3.5" Manual / Auto Reset Electric C50256-10 6413
Manual5' HARNESS WITH TOGGLE SWITCH 3.5" Manual / Auto Reset Electric C50256T 6412
Manual10' HARNESS WITH TOGGLE SWITCH 3.5" Manual / Auto Reset Electric C50256T-10 6412
AutomaticMAG 3/4" WITH 5' HARNESS 4.0" Auto / Auto Reset Electric C50228A 6325
AutomaticMAG 3/4" WITH 10' HARNESS 4.0" Auto / Auto Reset Electric C50228A-10 6334
Manual5' HARNESS WITH MEMBRANE SWITCH 4.0" Manual / Auto Reset Electric C50228 6413
Manual10' HARNESS WITH MEMBRANE SWITCH 4.0" Manual / Auto Reset Electric C50228-10 6413
Manual5' HARNESS WITH TOGGLE SWITCH 4.0" Manual / Auto Reset Electric C50228T 6412
Manual10' HARNESS WITH TOGGLE SWITCH 4.0" Manual / Auto Reset Electric C50228T-10 6412
PH
2P
H 3
CO
MP
ON
EN
TS
WA
RR
AN
TY
PH
1P
H 3
8
For the most UP-TO-DATE APPLICATION GUIDES visit our website: PowerHalt.com
800.663.0096 / www.powerhalt.com
APPLICATION GUIDES
PH3 POWERHALT SHUT-OFF VALVES
MAKE / MODEL SIZE CONTROL/ RESET ACTUATION KIT # INSTALL
MANUALCLASS 3-5 PICK-UP TRUCK / CHASSIS CAB TRUCKS 2013 - 2017 Dodge Ram 3.5" Auto / Auto Reset N/A C50254A 6409
2017 Ford 6.7L Powerstroke 2.75" Auto / Auto Reset N/A C50278A 6423
2011 - 2015 Mercedes Sprinter (3.0L V6) 2.25" Auto / Auto Reset N/A C50230A 6313
CLASS 6 - 8 COMMERCIAL HEAVY DUTY TRUCKSDetroit DD 13, 15 or 16 Engine 4.0" Auto / Auto Reset Electric C50223A 6332
Mack / Volvo Generic 3.5" Auto / Auto Reset Electric C50255A 6410
MX13 Engine (PUSH-IN TYPE MAG) 4.0" Auto / Auto Reset Electric C50242A 6369
STATIONARY EQUIPMENTUNIVERSALIsuzu 3CJ Engine 1.75" Auto / Auto Reset Electric C50246A 6325
LIGHT TOWERPH3 - LTW20 / 20KW / BV- 4LEZ Engine 2.0" Auto / Auto Reset Electric C50222A 6319
WELDERSPH3 Vantage 400 Welder 1.75" Auto / Auto Reset Electric C50224A 6325
PH3 POWERHALT SHUT-OFF VALVE ACCESSORIES
ACCESSORY MAKE / MODEL SYSTEM VOLTAGE KIT # INSTALL
MANUALAUXILIARY INPUT JUMPER HARNESSAuxiliary Input Jumper Harness Universal 12 VDC C50159 6396
Auxiliary Input Jumper Harness Universal 24 VDC C50159-24 6396
REV6_22.December.2016
PH
2P
H 3
CO
MP
ON
EN
TS
WA
RR
AN
TY
PH
1P
H 3
9
For the most UP-TO-DATE APPLICATION GUIDES visit our website: PowerHalt.com
800.663.0096 / www.powerhalt.com
CUSTOM ORDERS
SPH1 POWERHALT SHUT-OFF VALVES CUSTOM ORDER CHARTVALVE MODEL PH1 PART # CONTENTS
VALVE SIZE (OUTSIDE DIMENSION)
C50148 1.75" Valve
C50145 2.0" Valve
C50146 2.25" Valve
C50147 2.5" Valve
PULL CABLE
C50018 2 ft
C50022 4 ft
C50026 6 ft
C50030 8 ft
C50035 10 ft
MOUNTING GROUP
C50117 1.75"
C50118 2.0"
C50119 2.25"
C50116 2.5"
How to use the PH1 Custom Order Chart:
Place order using PH1 part numbers . Example PH1 Valve Order: C50148 C50018 C50117 2
Choose any other custom valve components. See Component Section. 3
Choose a: 1 VALVE MODEL VALVE SIZE PULL CABLE+ + + MOUNTING GROUP
PH
2P
H 3
CO
MP
ON
EN
TS
WA
RR
AN
TY
PH
1P
H 1
10
For the most UP-TO-DATE APPLICATION GUIDES visit our website: PowerHalt.com
800.663.0096 / www.powerhalt.com
CUSTOM ORDERS
SPH2 POWERHALT SHUT-OFF VALVES CUSTOM ORDER CHARTVALVE MODEL PH2
VALVE SIZE (OUTSIDE DIMENSION)
28 2.8"
30 3.0"
35 3.5"
40 4.0"
50 5.0"
SEAL S1 Buna O-Ring (-35°F - 250°F)
ACTUATION OPTIONS
P1 Pneumatic (12V 3-Way Solenoid + Pneumatic Cylinder)Manually open valve to run and solenoid energized + air to cylinder to shut valve
P2 Pneumatic (24V 3-Way Solenoid + Pneumatic Cylinder)Manually open valve to run and solenoid energized + air to cylinder to shut valve
C1 Pull Cable (with T-Handle)Manually open valve to run and t-handle cable pulled to shut valve
E1 Electric (12V Solenoid)Manually open valve to run and solenoid energized to shut valve
E2 Electric (24V Solenoid)Manually open valve to run and solenoid energized to shut valve
M1Electric + Pull Cable (12V Solenoid)Manually open valve to run and solenoid energized or cable pulled to shut valve*MUST PURCHASE THE PACBRAKE PULL CABLE SEPARATELY (see Component Section)
M2Electric + Pull Cable (24V Solenoid)Manually open valve to run and solenoid energized or cable pulled to shut valve*MUST PURCHASE THE PACBRAKE PULL CABLE SEPARATELY (see Component Section)
R1Electric + Dual Pull Cable (12V Solenoid)Manually open valve to run and solenoid energized or cable pulled to shut valve*MUST PURCHASE TWO PACBRAKE PULL CABLES SEPARATELY (see Component Section)
R2Electric + Dual Pull Cable (24V Solenoid)Manually open valve to run and solenoid energized or cable pulled to shut valve*MUST PURCHASE TWO PACBRAKE PULL CABLES SEPARATELY (see Component Section)
CONTROL OPTIONST1 Manual (Toggle Switch with Cover)
A1Automatic (Controller with Harness)**MUST PURCHASE A MAGNETIC PICK-UP SEPARATELY (see Component Section)
MOUNTING GROUPS There are many mounting groups available depending on the application, see the COMPONENT SECTION
How to use the PH2 Custom Order Chart:
Place order using PH2 VALVE ORDER CODE. Example PH2 Code: 28 S1 P1 T1 C50101 2
Choose a: 1 VALVE MODEL VALVE SIZE ACTUATION OPTION CONTROL OPTION MOUNTING GROUPSEAL+ + + + +
PH
2P
H 3
CO
MP
ON
EN
TS
WA
RR
AN
TY
PH
1P
H 2
11
For the most UP-TO-DATE APPLICATION GUIDES visit our website: PowerHalt.com
800.663.0096 / www.powerhalt.com
CUSTOM ORDERS
SPH3 POWERHALT SHUT-OFF VALVES CUSTOM ORDER CHARTVALVE MODEL PH3 PART # CONTENTS
VALVE SIZE (OUTSIDE DIMENSION)
C50087 1.75" Valve
C50088 2.0" Valve
C50089 2.25" Valve
C50097 2.5" Valve
C50096 2.75" Valve
C50090 3.0" Valve
C50098 3.5" Valve
C50086 4.0" Valve
CONTROL OPTIONS**
AUTOMATIC + MAGNETIC SENSOR
C50094Automatic Controller Membrane Switch 5' long Harness
C50093Automatic Controller Membrane Switch 10' long Harness
MANUAL
C50270Manual Controller Membrane Switch 5' Harness
C50271Manual Controller Membrane Switch 10' Harness
C50272Manual Controller Toggle Switch5' Harness
C50273Manual Controller Toggle Switch10' Harness
MOUNTING GROUPS There are many mounting groups available depending on the application, see the COMPONENT SECTION
* AUTOMATIC CONTROL OPTIONS MUST ALSO ADD A MAGNETIC PICK-UP** PICK THE CONTROL KIT OPTIONS BASED ON THE LENGTH OF HARNESS
How to use the PH3 Custom Order Chart:
Place order using PH3 part numbers. Example PH3 Valve Order: C50087 C50094 C50117 * 2
Choose any other custom valve components. See Component Section. 3
Choose a: 1 VALVE MODEL VALVE SIZE CONTROL OPTION MOUNTING GROUP+ + + *
PH
2P
H 3
CO
MP
ON
EN
TS
WA
RR
AN
TY
PH
1P
H 3
12800.663.0096 / www.powerhalt.com
PowerHalt Components
CUSTOM VALVE COMPONENTS
PULL CABLE (for valves with pull cable actuation)
LENGTH PART #2 ft C50018
4 ft C50022
6 ft C50026
8 ft C50030
10 ft C50035
16 ft* C50149
20 ft* C50160
*FOR PH2 VALVES ONLY. Must also purchase C50161 cable mounting group.
MAGNETIC PICK-UP (for auto kits only**)
THREAD SIZE PART #N/A – Push In Style – Variable Reluctance C50132
⅜ – 24 UNF 2" [51 mm] C50032
⅜ – 24 UNF 3" [76 mm] C500955⁄8 – 18 UNF 2" [51 mm] C500335⁄8 – 18 UNF 2.5" [64 mm] C502793⁄4 – 16 UNF 2.5" [64 mm] C50034
**Automotive Class 3-5 Kits use factory Speed Sensor
MOUNTING KITS (comes with 2 silicone hoses and 4 clamps)
VALVE SIZE DESCRIPTION PART #1.75" To 1.75" Pipe (Straight Hose) C50117
2.0" To 2.0" Pipe (Straight Hose) C50118
2.25" To 2.25" Pipe (Straight Hose) C50119
2.5" To 2.5" Pipe (Straight Hose) C50116
2.8"
To 2.5" Pipe (Reducer Hose) C50100
To 2.75" Pipe (Straight Hose) C50101
To 3.0" Pipe (Reducer Hose) C50102
3.0" To 3.0" Pipe (Straight Hose) C50105
3.5" To 3.0" Pipe (Reducer Hose) C50103
To 3.5" Pipe (Straight Hose) C50104
4.0"
To 3.5" Pipe (Reducer Hose) C50106
To 4.0" Pipe (Straight Hose) C50107
To 4.5" Pipe (Reducer Hose) C50108
5.0"
To 4.5" Pipe (Reducer Hose) C50109
To 5.0" Pipe (Straight Hose) C50110
To 5.5" Pipe (Reducer Hose) C50111
For more info on components view our PowerHalt catalogue:pacbrake.com/home/online-product-catalogues/
For more info on components view our PowerHalt catalogue: pacbrake.com/home/online-product-catalogues/
PH
2P
H 3
CO
MP
ON
EN
TS
WA
RR
AN
TY
PH
1
13
CUSTOMER INFORMATIONCompany Name EmailBuyers Name Phone NumberBuyers Title FaxCompany Address Product Ship-To AddressSpecial Shipping Instructions/Packaging
APPLICATION INFORMATION Ground (Stationary) Ground (Mobile) Marine
Additional Application Information?
ENGINE INFORMATIONEngine Make Engine YearModel Serial/VIN # Any Additional Add-On Aftermarket Performance Products on the Engine?
AIR INTAKE SYSTEM INFORMATION [at shut-off valve location(s)]Intake Air Temperature Intake Air PressureIntake Pipe MaterialIntake Pipe Outside Diameter Hose Inside Diameter
ENGINE SYSTEM CONTROL INFORMATIONPreferred Activation Type: Electric Pull Cable Pneumatic 12VDC 24VDC Pull Cable Length Available Pressure
Automatic Control Option? Yes No Magnetic Pick-Up for RPM Sensing Can Be Installed? (PowerGuard Kit) Yes No
Additional Valve Features Required: Auto-Reset Function Fuel Shutdown Function Proximity Switch with Valve Position Sensing
In order of preferred location to least preferred
1st POST INTERCOOLER■ Low Plumbing Leakage Risk■ Moderate Charge Air Temperature■ Fast Shutdown Response Time
2nd POST TURBO■ Moderate Plumbing Leakage Risk■ High Charge Air Temperature■ Moderate Shutdown Response Time
3rd PRE TURBO■ High Plumbing Leakage Risk■ Low Charge Air Temperature■ Slow Shutdown Response Time
1st
2nd 3rd
OPTIMALPERFORMANCE
ACCEPTABLE(Not recommended)(Recommended)
800.663.0096 / www.powerhalt.com
PACBRAKE PRODUCT CATALOGUE
New Product Development
PH
2P
H 3
CO
MP
ON
EN
TS
WA
RR
AN
TY
PH