Post on 09-Dec-2021
WAITING
23-00
RECEPTION
23-22
BARIATRIC
TOILET RM.
23-02
EXAM RM. #1
23-03
23-04
23-05
23-06
EXAM
RM. #5
23-07
CONSULT
RM.
23-08
STOR.
23-10
STOR.
23-12
NU
RS
E
23
-0
9
BP
/W
EIG
HT
23
-1
1
23-14
EXAM
RM. #7
23-15
OFFICE.
23-13
OFFICE.
23-18
BREAK RM.
23-17
TOILET
RM.
23-20
STOR.
23-19
SOILED
23-21
CO
RR
ID
OR
23
-2
3
CO
RR
ID
OR
23
-2
5
CORRIDOR
23-24
COATS
23-01
EXAM
RM. #6
EXAM
RM. #4
EXAM
RM. #4
EXAM
RM. #4
EXAM
RM. #8
23-16
1. REFER TO DIFFUSER SCHEDULE LOCATED ON M-103a FOR ALL DUCT RUN-OUTS NOT
SPECIFICALLY SHOWN ON PLAN.
2. REFER TO MECHANICAL SHEET M-100 FOR ALL ABBREVIATIONS, LEGEND AND
SYMBOLS.
3. MECHANICAL CONTRACTOR SHALL HOLD ALL DUCTWORK AS TIGHT AS POSSIBLE TO
UNDERSIDE OF STRUCTURE.
4. MECHANICAL CONTRACTOR SHALL COORDINATE DUCT ROUTING WITH LIGHTING. NO
DUCTWORK SHALL BE ROUTED UNDER ANY LIGHT FIXTURES.
5. ALL ROOFTOP EQUIPMENT SHALL BE INSTALLED A MINIMUM OF 10'-0" FROM EDGE
OF ROOF.
6. SPIN-IN OR TAB-TYPE FITTINGS WITH AIR SCOOPS SHALL BE PROVIDED FOR ALL
ROUND BRANCH TAPS.
7. FLEX CONNECTIONS TO DIFFUSERS ARE TO BE INSULATED FLEX WITH A MAXIMUM
LENGTH OF 5 FEET.
8. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION WITH
ELECTRICAL CONTRACTOR REGARDING THE WIRING OF ALL MECHANICAL
EQUIPMENT.
9. PROVIDE BALANCE DAMPERS AT ALL BRANCH DUCTS SERVING DIFFUSERS IN
ACCESSIBLE SPACE, IF TAKE OFF IS LOCATED IN NON-ACCESSABLE SPACE PROVIDE
OBD AT DIFFUSER.
10. PIPE AND DUCTS PASSING THRU HORIZONTAL ASSEMBLIES SHALL BE PROTECTED
WITH AN APPROVED NON-COMBUSTIBLE MATERIAL TO RESIST THE FREE PASSAGE
OF FLAME AND THE PRODUCTS OF COMBUSTION.
11. HEATING EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH UNDERWRITER'S
APPROVAL, MANUFACTURER'S RECOMMENDATIONS, GOOD ENGINEERING PRACTICE
AND THE STATE MECHANICAL CODE AND THE INTERNATIONAL FUEL GAS CODE.
12. CONTRACTOR SHALL COORDINATE LOCATION OF AIR DEVICES WITH REFLECTED
CEILING PLAN AND LIGHTING LAYOUT.
13. TRANSITION ANY DUCTS THAT OVERLAP TO SQUARE DUCTWORK OF EQUIVALENT
FREE AREA AS REQUIRED.
14. ALL EXHAUST FANS SHALL HAVE INTEGRAL BACK DRAFT DAMPER.
15. MOUNT TOP OF THERMOSTATS A MAXIMUM OF 4'-0" AFF UNLESS NOTED
OTHERWISE. PROVIDE CLEAR LOCKING GUARD ASSEMBLIES FOR ALL PUBLIC AREA
THERMOSTATS. COVER SHALL BE ADA COMPLIANT. COORDINATE THERMOSTAT
LOCATIONS WITH OTHER TRADES. ALL THERMOSTAT LOCATIONS SHALL BE ADA
COMPLIANT.
16. ALL WORK BELOW ENT SPACE SHALL BE PROVIDED FOR OFF HOURS. ALL
SHUTDOWNS AND WORK SHALL BE COORDINATED WITH THE LANDLORD AND 48
HOURS NOTICE SHALL BE PROVIDED PRIOR TO ALL WORK OUTSIDE OF THE ENT
SUITE. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CLEAN UP, TEMPORARY
PROTECTION, SECURITY AND DAMAGE
17. FURNISH AND INSTALL DUCTWORK IN ACCORDANCE WITH DETAIL 9/M101 ON ALL
WALLS THAT EXTEND TO THE DECK. COORDINATE LOCATIONS IN THE FIELD.
RETURN AIR PLENUM SHALL BE FULL SIZE OF UNIT RETURN. FILTER SHALL BE
LOCATED ON UNIT OPENING. RETURN PLENUM SHALL BE MINIMUM OF 24" IN
LENGTH, AND LINED BY 1" DUCT LINER FOR SOUND ATTENUATION.
FURNISH AND INSTALL RETURN GRILLE AND DUCT CONFIGURATION AS SHOWN
IN DETAIL 9
UNDERCUT DOOR 3/4".
FURNISH AND INSTALL NEW 6" EXHAUST AIR DUCT TO EXISTING BUILDING HEAT
RECOVERY SYSTEM.
NEW HEAT PUMP AS SCHEDULED.
CONNECT OUTSIDE AIR DUCT FOR ALL WSHP TO EXISTING BUILDING OUTSIDE
AIR SYSTEM WITH NEW VAV BOX. WIRING BY DVL.
CONTRACTOR SHALL ROUTE NEW 1" CD DRAIN TO CLOSEST EXISTING
CONDENSATE DRAIN OF ADEQUATE SIZE AND LOCATION, CONTRACTOR SHALL
COORDINATE ROUTING AND LOCATION WITH EXISTING CONDITIONS PRIOR TO
COMMENCING WORK.
FURNISH AND INSTALL NEW 1" CWS/R TO NEAREST EXISTING BUILDING
CONDENSER WATER LOOP
FURNISH AND INSTALL NEW VAV BOX TITUS-10 AND DUCTWORK FROM BUILDING
OUTSIDE AIR SUPPLY SYSTEM. VERIFY EXACT LOCATION IN THE FIELD
10"Ø
1
M-200
MECHANICAL PARTIAL FLOOR PLAN
SCALE: 1/4" =1'-0"
Mechanical Floor
Plan
M-200
Project
Architecture
Interior Design
Environmental Graphics
Recognition Design
Mitchell Associates
One Avenue of the Arts
Wilmington DE 19801-5047
302 594 9400 Fax
302 656 7926
www.mitchellai.com
Scale
Project No
Date
Drawn By
Sheet No
Version
Checked By
Sheet Title
Project
Architecture
Interior Design
Environmental Graphics
Recognition Design
Mitchell Associates
One Avenue of the Arts
Wilmington DE 19801-5047
302 594 9400 Fax
302 656 7926
www.mitchellai.com
Scale
Project No
Date
Drawn By
Sheet No
Version
Checked By
1 CB/MG 02/04/15
ISSUED FOR BID
As NotedAs Noted
14087
02/04/15
STAFF
MG
500 Evergreen Drive
Suite 23 - Han
Multi-Speciality Suite
Brinton Lake Corporate Center
Concord Township
Delaware County
Pennsylvania
1 CB/MG 02/09/15
ADDENDUM #1
PLUMBING SYMBOLS & ABBREVIATIONS GENERAL NOTES PLUMBING SPECIFICATION
1. ALL FIXTURES SHALL BE REVIEWED BY THE LANDLORD FOR COMPLIANCE WITH CURRENT LANDLORD STANDARDS.
2. REFER TO ARCHITECTURAL DRAWINGS FOR FIXTURE MOUNTING HEIGHTS.
3. COORDINATE COLOR SELECTION OF FIXTURES WITH ARCHITECT PRIOR TO ORDERING.
4. REFER TO ARCHITECTURAL PLANS FOR ACCESSORIES NOT INDICATED WITHIN FIXTURE SCHEDULE.
5. MILLWORK TO BE PROVIDED BY OTHERS.
6. CONCEALED FITTING SHALL BE ROUGH BRASS. EXPOSED TRIM AND FITTINGS SHALL BE CHROME PLATED.
7. COORDINATE ROUGH-IN LOCATIONS WITH STRUCTURAL PLANS.
8. CONTRACTOR SHALL FURNISH AND INSTALL VENT UP THRU ROOF FROM FIXTURES GREATER THAN 8' FROM VENT STACK. OFFSET AS REQUIRED.
9. CONTRACTOR SHALL FURNISH AND INSTALL ALL DOMESTIC COLD WATER AND DOMESTIC HOT WATER PIPING TO EACH FIXTURE. ALL HEADERS SHALL BE
3
4
" AND RUNOUTS SHALL BE SIZED PER TABLE ABOVE. FURNISH AND INSTALL WATTS THERMOSTATIC MIXING
VALVE LF707 ON ALL SINKS
10. PLUMBING FIXTURES SHOWN IN FIXTURE SCHEDULE ARE TO BE LOW FLOW FIXTURES
LAV FAUCETS = 2.0 GAL/MIN MAX
WC 1.6 GAL/MIN MAX
SK-1
MARK
LAV-1
WC-1
1/2"1/2" 1 1/2"
COLD
1-1/2"
WATER
-
WATER
HOT
VENT
2"WATER CLOSET, ADA
LAVATORY, ADA
2"
WASTE
3"
REMARKS
1/2"1/2" EXAM ROOM SINK1 1/2" 2"
-
FD FLOOR DRAIN
1/2"
2"
-
1 1/2"
SK-2
AMERICAN STANDARD
FIXTURE MAKE FIXTURE MODEL#
ELKAY
ELKAY
WATTS FD-100 SERIES
2257.103
LFRAD1918
-
-
TRIM MAKE TRIM MODEL#
ADA
-
MOEN 8799
-
KOHLER K-2005CARRIER - WADE520,09,M23/MOEN 8810
LAB
-
NOTES
WALL HUNG, SPUD
EPOXY COATED CAST IRON, ADJUSTABLE NICKEL-BRONZE ROUND STRAINER, 8" STRAINER, SEDIMENT BUCKET, TRAP PRIMER TAP AND PIPING
POP-UP DRAIN, CHROME TAIL PIECE, CAT BRASS P-TRAP AND ANGLE STOP SUPPLIES, TRUEBRO LAV-GUARD TAP AND SUPPLY COVERS, FURNISH AND INSTALL WATTS LFL1170
POP-UP DRAIN, CHROME TAIL PIECE, CAT BRASS P-TRAP AND ANGLE STOP SUPPLIES, TRUEBRO LAV-GUARD TAP AND SUPPLY COVERS, FURNISH AND INSTALL WATTS LFL1170
1/2"1/2" TRAP PRIMER
- -
TP-1 PPP PR-500
- - -
ATMOSPHERIC VACUUM BREAKER
----
CO CLEAN OUT SIOUX CHIEF 875 SERIES
- - -
BUSHING ONLY
----
WCO WALL CLEAN OUT WATTS CO44
- - -
POLY PLUG WITH BRASS INSERT, STAINLESS STEEL COVER, VANDAL PROOF
3/4"
-
3/4"3/4"WH-1 AO SMITH
40 gallon
- -
4.5KW/480V, PROVIDE WITH TWO 4500W ELEMENT FOR SIMULTANEOUS OPERATION, INSTALL ABOVE CEILING, PIPING IN ACCORDANCE WITH THE DETAIL.
1-1/2"2"1/2"1/2"EWC
-
EZS8L ADA
-
-ELKAY
SELECTRONIC 6065.161.002
1/2"1/2" 1 1/2" 2"
POP-UP DRAIN, CHROME TAIL PIECE, CAT BRASS P-TRAP AND ANGLE STOP SUPPLIES, FURNISH AND INSTALL WATTS LFL1170
BALL VALVE &
DIELECTRIC UNION
(TYP)
1" COPPER DWV DISCHARGE
INDIRECTLY WITH MIN 6" AIR GAP
T&P RELIEF VALVE
HOT WATER SUPPLY
COLD WATER SUPPLY
GALVANIZED SHEET
METAL DRAIN PAN
1. WIRING BY ELECTRICAL CONTRACTOR.
2. COORDINATE SPACE REQUIRED BETWEEN CLG. AND
BOTTOM OF DECKING/FLOOR ABOVE WITH ARCHITECT
PRIOR TO INSTALLATION.
3. PLATFORM TYPE SHOWN ABOVE. CONTRACTOR TO PROVIDE
SUPPORT AND PLATFORM.
DRAIN VALVE
COPPER DWV, FULL SIZE OF T&P
OUTLET (1" MIN.) TO DISCHARGE
INDIRECTLY WITH A MIN. 6" AIR GA
WATTS 288A
ANT-SIPHON
VACUUM BREAKER
FURNISH AND INSTALL AMTROL
THERM-X-TROL ST-8
LAV-2LAVATORY, ADA
WILLOUGHBY INDUSTRIES BHS-3123 MOEN 8810 WITH 4" WRISTBLADESADA POP-UP DRAIN, CHROME TAIL PIECE, CAT BRASS P-TRAP AND ANGLE STOP SUPPLIES, TRUEBRO LAV-GUARD TAP AND SUPPLY COVERS, FURNISH AND INSTALL WATTS LFL11701/2"1/2" 1 1/2" 2"
WC-2 1-1/2"
-
2"WATER CLOSET, ADA
3" Dura-Ware 2125-A SERIES
-
FLOOR MOUNTEDSELECTRONIC 6065.161.002
LRAD2522 LUNCH ROOM DELTA 400/LAB MOEN 8799ADA
Plumbing
Legend
P-100
Project
Architecture
Interior Design
Environmental Graphics
Recognition Design
Mitchell Associates
One Avenue of the Arts
Wilmington DE 19801-5047
302 594 9400 Fax
302 656 7926
www.mitchellai.com
Scale
Project No
Date
Drawn By
Sheet No
Version
Checked By
Sheet Title
Project
Architecture
Interior Design
Environmental Graphics
Recognition Design
Mitchell Associates
One Avenue of the Arts
Wilmington DE 19801-5047
302 594 9400 Fax
302 656 7926
www.mitchellai.com
Scale
Project No
Date
Drawn By
Sheet No
Version
Checked By
1 CB/MG 02/04/15
ISSUED FOR BID
As NotedAs Noted
14087
02/04/15
STAFF
MG
500 Evergreen Drive
Suite 23 - Han
Multi-Speciality Suite
Brinton Lake Corporate Center
Concord Township
Delaware County
Pennsylvania
1 CB/MG 02/09/15
ADDENDUM #1
WAITING
23-00
RECEPTION
23-22
BARIATRIC
TOILET RM.
23-02
EXAM RM. #1
23-03
23-04
23-05
23-06
EXAM
RM. #5
23-07
CONSULT
RM.
23-08
STOR.
23-10
STOR.
23-12
NU
RS
E
23
-0
9
BP
/W
EIG
HT
23
-1
1
23-14
EXAM
RM. #7
23-15
OFFICE.
23-13
OFFICE.
23-18
BREAK RM.
23-17
TOILET
RM.
23-20
STOR.
23-19
SOILED
23-21
CO
RR
ID
OR
23
-2
3
CO
RR
ID
OR
23
-2
5
CORRIDOR
23-24
COATS
23-01
EXAM
RM. #6
EXAM
RM. #4
EXAM
RM. #4
EXAM
RM. #4
EXAM
RM. #8
23-16
FURNISH AND INSTALL NEW METER. DVL SHALL PROVIDE WIRING
AND MONITORING FOR THESE METERS. METER SHALL BE DWYER
SERIES WMT MULTI-JET WATER/PULSED OUTPUT.
CONNECT NEW 1-1/2" DCW SUPPLY. CONTRACTOR SHALL
COORDINATE EXACT LOCATION PRIOR TO COMMENCING WORK.
CONTRACTOR SHALL CONNECT NEW 3" VENT TO EXISTING VENT
PIPING OF ADEQUATE SIZE. CONTRACTOR SHALL VERIFY EXISTING
LOCATION AND ROUTING PRIOR TO COMMENCING WORK.
CONNECT NEW 3" SANITARY TO EXISTING SANITARY IN THE
BUILDING
A. THE DRAWINGS ARE GENERALLY DIAGRAMMATIC AND IT IS THE
INTENT AND MEANING OF THE CONTRACT DOCUMENTS THAT
THE CONTRACTOR SHALL PROVIDE A PLUMBING INSTALLATION
THAT IS COMPLETE AND ALL ITEMS AND APPURTENANCES
NECESSARY, REASONABLE INCIDENTAL, OR CUSTOMARILY
INCLUDED, EVEN THOUGH EACH AND EVERY ITEM IS NOT
SPECIFICALLY CALLED OUT OR SHOWN. THE CONTRACTOR
SHALL PROVIDE ALL EQUIPMENT, MATERIALS, LABOR,
SUPERVISION AND SERVICE NECESSARY SO AS TO PROVIDE A
COMPLETE, FUNCTIONING PLUMBING SYSTEM IN SAFE WORKING
ORDER.
B. SYMBOLS FOR VARIOUS ELEMENTS AND SYSTEMS ARE SHOWN
ON THE DRAWINGS. SHOULD THERE BE ANY DOUBT REGARDING
THE MEANING OR INTENT OF THE SYMBOLS USED, AN
INTERPRETATION SHALL BE OBTAINED FROM THE ARCHITECT IN
WRITING. THE DECISION OF THE ARCHITECT SHALL BE FINAL.
C. WHEREVER CONFLICTS OCCUR BETWEEN DIFFERENT PARTS OF
THE CONTRACT DOCUMENTS, THE GREATER QUANTITY, THE
BETTER QUALITY, OR LARGER SIZE SHALL PREVAIL UNLESS THE
ARCHITECT INFORMS THE CONTRACTOR OTHERWISE IN
WRITING.
D. ONLY EXPERIENCED CRAFTSMEN KNOWLEDGEABLE IN THEIR
RESPECTIVE TRADE SHALL PERFORM THE WORK DESCRIBED IN
THE CONSTRUCTION DOCUMENTS.
E. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH
MANUFACTURER'S PUBLISHED RECOMMENDATIONS FOR
SERVICE INTENDED, AS INTERPRETED BY THE ENGINEER.
EXPERIENCED CRAFTSMEN SHALL MAKE THE INSTALLATION OF
ALL EQUIPMENT IN A NEAT WORKMANSHIP LIKE MANNER. THE
CONTRACTOR SHALL FURNISH ALL MATERIALS, TOOLS, COST
AND SERVICE NECESSARY TO COMPLETELY INSTALL ALL
MECHANICAL WORK. ALL MECHANICAL AND PLUMBING
EQUIPMENT SHALL BE AS SCHEDULED OR APPROVED EQUAL.
F. PROPERLY SUPPORT ALL EQUIPMENT AND PIPING WITHIN THE
BUILDING AND PROVIDE ADEQUATE PROVISIONS FOR SLOPE
AND ANCHORAGE. CONTRACTOR SHALL USE HANGERS, RODS
AND INSERTS APPROVED BY UNDERWRITERS LABORATORIES
FOR THE SERVICE INTENDED, SECURELY SUPPORTED BY
STRUCTURAL MEMBERS WHICH IN TURN ARE SUPPORTED
DIRECTLY FROM THE BUILDING STRUCTURE.
G. THIS WORK SHALL BE EXECUTED IN STRICT CONFORMITY WITH
BASE BUILDING SPECIFICATION AND WITH THE LATEST EDITION
OF THE PREVAILING STATE PLUMBING AND BUILDING CODES
AND ALL LOCAL REGULATIONS THAT MAY APPLY. IN CASE OF
CONFLICT BETWEEN THE CONTRACT DOCUMENTS AND A
GOVERNING CODE OR ORDINANCE THE MORE STRINGENT
STANDARD SHALL APPLY.
H. ALL UNDERGROUND SANITARY WASTE PIPING SHALL BE
SOLVENT SEAL SCHEDULE 40 PVC-DWV OR GASKETED
HUB/SPIGOT CAST IRON. ABOVE GROUND SHALL BE SOLVENT
SEAL SCHEDULE 40 PVC-DWV OR HUBLESS CAST IRON WITH
MECHANICAL COUPLINGS AND SLOPED A MINIMUM OF
1
8
" PER
FOOT (2-1/2'' OR LARGER) AND
1
4
'' PER FOOT (2" OR SMALLER)
WHERE INSTALLED IN THE HORIZONTAL POSITION. MATERIAL
SHALL COMPLY WITH CODE REQUIREMENTS.
I. ALL VENT PIPING SHALL BE SOLVENT SEAL SCHEDULE 40
PVC-DWV OR THREADED GALVANIZED STEEL IF BELOW GRADE.
MATERIAL SHALL COMPLY WITH CODE REQUIREMENTS. NO PVC
SHALL BE USED IN RETURN AIR PLENUM.
J. DOMESTIC WATER PIPING BELOW GRADE OR SLAB SHALL BE
BRAZED TYPE 'K' COPPER, WATER PIPING ABOVE SLAB SHALL BE
SOLDERED TYPE 'L' OR MECHANICAL CRIMP JOINT. INSULATE
WATER PIPING WITH
1
2
" ARMAFLEX II OR EQUAL BY RUBATEX OR
ARMACELL.
K. ALL FLOOR DRAIN TRAPS SHALL BE PROVIDED WITH TRAP
PRIMERS PER LOCAL CODES HAVING JURISDICTION.
L. ALL HORIZONTAL VENT PIPING MAY NOT BE SHOWN ON THIS
PLAN FOR THE SAKE OF CLARITY. REFER TO SANITARY
ISOMETRIC FOR VENT PIPING ROUTING AND PROVIDE COMPLETE
VENTING SYSTEM IN ACCORDANCE WITH CODE.
M. ALL PLUMBING WORK SHALL BE COORDINATED WITH ALL OTHER
TRADES PRIOR TO PROCEEDING WITH INSTALLATION.
N. ALL DOMESTIC WATER BRANCH LINES SHALL HAVE FULL PORT,
TWO PIECE BALL TYPE ISOLATION VALVES.
O. PROVIDE WATER HAMMER ARRESTORS (WHA) AT ALL WATER
PIPE DROPS TO FIXTURES WITH QUICK CLOSING VALVES AND ON
SYSTEMS WITH HIGHER THAN NORMAL PRESSURE WHERE
WATER HAMMER MAY BE AN ISSUE.
P. INSTALL ALL FLOOR CLEANOUTS TO CLEAR EQUIPMENT AND
PROVIDE REQUIRED ACCESSIBILITY FOR MAINTENANCE.
Q. VERIFY INVERT ELEVATIONS AND EXACT LOCATIONS OF ALL
UNDERGROUND UTILITIES PRIOR TO INSTALLING ANY
UNDERGROUND PIPING. COORDINATE WITH SITE UTILITY
CONTRACTOR.
R. ALL WORK BELOW ENT SPACE SHALL BE PROVIDED FOR OFF
HOURS. ALL SHUTDOWNS AND WORK SHALL BE COORDINATED
WITH THE LANDLORD AND 48 HOURS NOTICE SHALL BE
PROVIDED PRIOR TO ALL WORK OUTSIDE OF THE ENT SUITE.
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CLEAN UP,
TEMPORARY PROTECTION, SECURITY AND DAMAGE
SK-2
1
2
"DCW
1
2
"DHW
2"VENT
SK-2
1
2
"DCW
1
2
"DHW
2"VENT
SK-2
1
2
"DCW
1
2
"DHW
2"VENT
SK-2
1
2
"DCW
1
2
"DHW
2"VENT
LAV-2
1
2
"DCW
1
2
"DHW
2"VENT
WC-2
1"DCW
2"VENT
SK-2
SK-1
1
2
"DCW
1
2
"DHW
2"VENT
LAV-1
1
2
"DCW
1
2
"DHW
2"VENT
WC-1
1"DCW
3"VENT
1-1/2" DCW
1" DHW
3" VENT
1" DCW
1" DHW
2" VENT
1" DCW
1" DHW
2" VENT
1-1/4" DCW
1" DHW
3" VENT
1-1/4" DCW
1" DHW
3" VENT
1-1/4" DCW
1" DHW
3" VENT
1-1/4" DCW
1" DHW
3" VENT
3
4
" DCW
3
4
" DHW
2" VENT
FOR EACH
SINK
3
4
" DCW
3
4
" DHW
2" VENT
FOR EACH
SINK
3
4
" DCW
3
4
" DHW
2" VENT
FOR EACH
SINK
3
4
" DCW
3
4
" DHW
2" VENT
FOR EACH
SINK
SK-2
1
2
"DCW
1
2
"DHW
2"VENT
SK-2
1
2
"DCW
1
2
"DHW
2"VENT
SK-2
1
2
"DCW
1
2
"DHW
2"VENT
SK-2
1
2
"DCW
1
2
"DHW
2"VENT
1
P-200
PLUMBING DOMESTIC WATER AND VENT
SCALE: 1/4" =1'-0"
Plumbing Vent
And Domestic Water
P-200
Project
Architecture
Interior Design
Environmental Graphics
Recognition Design
Mitchell Associates
One Avenue of the Arts
Wilmington DE 19801-5047
302 594 9400 Fax
302 656 7926
www.mitchellai.com
Scale
Project No
Date
Drawn By
Sheet No
Version
Checked By
Sheet Title
Project
Architecture
Interior Design
Environmental Graphics
Recognition Design
Mitchell Associates
One Avenue of the Arts
Wilmington DE 19801-5047
302 594 9400 Fax
302 656 7926
www.mitchellai.com
Scale
Project No
Date
Drawn By
Sheet No
Version
Checked By
1 CB/MG 02/04/15
ISSUED FOR BID
As NotedAs Noted
14087
02/04/15
STAFF
MG
500 Evergreen Drive
Suite 23 - Han
Multi-Speciality Suite
Brinton Lake Corporate Center
Concord Township
Delaware County
Pennsylvania
1 CB/MG 02/09/15
ADDENDUM #1