CONTENTSHeating with pellets 4 - 5
Nano-PK 6 - 12 kW 6 - 7
HSV 9 - 22 kW 8 - 9
Classic 9 - 22 kW 10 - 11
Classic Lambda 25 - 60 kW 12 - 13
Eco PK 70-12 14 - 15
WTH 150 - 200 kW 16 - 17
Lambda Touchtronic 18 - 19
Fuel storage overview 20 - 21
Transportation 22 - 25
Heating modules 26 - 27
Accessories 28
Accumulators 29
Technical data 30 - 31
Our vision is for a harmony between satisfied customers and the environment
3
Recommended by our customersAnton, Elisabeth and their sons, Anton & Markus Hargassner
In order to lower emission values in oil or gas reliant countries, Hargassner is endeavouring to make high-performance biomass heating technology available to everyone.The company currently exports to more than 25 countries. The most important markets are Germany, France, Switzerland, Spain, Italy, Belgium, the Netherlands and the UK. However, Scandinavia, Ukraine, Czech Republic, Bulgaria, Greece, Slovenia, Hungary, Japan, New Zealand and North America are growing markets, which are trying to reduce their CO
2 emissions as well.
At this time, exports account for 70% of our annual turnover. Numerous awards confirm that our philosophy is more than just lip-service.
House, 49 kW Pellet Boiler, Ukraine
Fire department, 100 kW Pellet Boiler, SpainLingfield Racecourse, 100 kW Pellet Boiler, United Kingdom
4
Pellets are made from 100% natural wood without any additives. Tonnes of wood waste materials are produced every day in wood-processing industries all over Europe.
The advantages for homeowners and industrial companies are obvious:
✔ Lower costs than oil or gas ✔Crisis-resistant, because of locally sourced fuel ✔ Short transportation ✔ Easy refuelling through blown pellet delivery ✔Dust-free, odourless refill ✔ Small storage volume ✔ Effective and energy-efficient heating system
Pellet Boilers
Classic 9 - 22 kWHSV 9 - 22 kW
Advantages of Pellet Boilers
Pellets are an environmentally-friendly and CO2 neutral fuel from your local area.
Therefore, pellets are an outstanding fuel for heating systems compared to fossil fuels like oil, electricity or heat pumps.
Nano-PK 6 - 12 kW
NEW
energy saving &
cost-effective
Classic Lambda 25 - 60 kW
* based on average fuel price over the last 10 years Source: Statistik Österreich, Energie Control, Pelletsverband, Biomasseverband, Landwirtschafts- und Arbeiterkammer Österreich.
5
WTH 150 - 200ECO PK 70 - 120 kW
Basis: Pellet = 210 Euro / tonne * Oil = 0.75 Euro / l * Gas = 65 Euro / MWh *
Example: 100 kW boiler, using pellets verses oil or gas
Annual cost savings*
Pellet : Oil Savings: approx € 6 011
Pellet : Gas Savings: approx € 4 141
Pellet: Oil / Gas
Savings:
approx € 6 011 compared to oil
approx € 4 141 compared to gas
Pellet Characteristics (EN 14961, Önorm M7135)
Standards ÖNorm M7135 EN 14961 – Class A1Heating value > 18 MJ/kg = 5 kWh/kg 16.5 ≤ Q ≤19 MJ/kg = 5 kWh/kg
Weight 650 kg/m³ > 600 kg/m³
Diameter 6 mm ≤ 6 ± 1.0 mm
Length 5 – 40 mm 3.15 ≤ L ≤ 40 mm (99%), L ≤ 45mm (1%)
Water content w < 10 % w ≤ 10 %
Dust content ≤ 1 % ≤ 1 %
Ash content < 0.5 % ≤ 0.7 %
Energy used for pellet production ~ 2.7% of energy output
6
The Compact Heating Solution
Compact designIdeal for small installations or boiler rooms and for houses with low heating demands.Space requirement: 0.45 m² / 4.87 ft²
Installation up against 3 wallsNo additional access for maintenance is required. The unit can be installed against a wall with no side access.
Easy installationAll connections, such as flue, pellet transport tubes or hydraulic connections, are from the top. This saves time and money for installation.
Integrated hydraulic moduleThe heat circuit HWS pump, the accumulator loading pump/circulation pump and all other pipework is integrated into the boiler, is easy to access and ready to connect.
Maintenance access from the front and top onlyAll components of the boiler are designed to be reached from the front, with the slogan: "Small is good - but it must be service-friendly."
Quick and easy to transportThe pellet boiler consists of only one piece and is therefore very easy to transport. No disassembly for installation is necessary.
Transport time 15min
NEW
1
2
8
9
10
3
4
14
5
6 7
7
Nano-PK 6 - 12 kW
Trust the proven HARGASSNER standards
Low temperature pellet boiler - 38°C Hargassner's outside temperature measurement system allows the boiler’s control unit to smoothly regulate the heat output. The boiler flow temperature can be altered from 38°C to 75°C with constant 95% efficiency. Only the required energy is generated.
Fully refractory lined high temperature combustion chamber with Lambda sensorRefractory has proven itself to be the best material available in terms of heat storage, function and durability. The high combustion chamber temperature at full and partial load contributes to a complete combustion, high efficiency and lowest emission values. The Lambda sensor regulates exactly the right quantity of fuel in every output range according to the pellet quality. This is the only way to guar-antee an optimum (i.e. economical and low emission) combustion that can save energy and money, with more than 95% efficiency.
Integrated Touch Control, plug&play The all new Lambda Touchtronic is the ultimate control system with an exceptional design and simple handling. Complicated navigation is a thing of the past.
01 Fully refractory lined combustion chamber02 Sliding grate03 Secondary air stream with inlet openings04 Primary air05 Ash box06 Automatic ignition07 Stoker auger08 Heat exchanger09 Turbulators with automatic heat
exchanger cleaning10 Exhaust fan11 Pellet-Vacuum turbine12 Pellet day hopper13 Double rotary valve14 Lambda sensor standard
EXPLANATION
OPTIONAL:
Air independent mode
✔ Compact design ✔ Installation up against 3 walls ✔ Latest design and cutting-edge technology ✔ Highly efficient with lowest cost of ownership ✔ Easy installation ✔ Low temperature boiler - 38 °C ✔ Double rotary valve ✔ Fully refractory-lined combustion chamber ✔ Touch-Display
11
13
12
7
8
Circulation zone for best burn-outAirbourne particles from the combustion chamber end in a circling stream of gas before fully burning out.
Fully refractory-lined high temperature combustion chamber
Refractory has proven itself as the best material available in terms of heat storage, function and durability. The high combustion chamber temperature contributes to a complete combustion and over 93 % efficiency at full and partial load.
Automatic sliding grateThe well-engineered sliding grate system of Hargassner’s pellet boilers cleans itself fully automatically and combustion residues end up in the ash box. Primary air is consistently blown in via the grate and the ignition takes place automatically by a hot-air fan. Optimum afterburning and excellent emission values are guaranteed by preheated secondary air.
Ash box with integrated compressionA distribution mechanism mounted below the moving sliding grate ensures that the ash will be compressed and filled to the top of the box. This leads to extended emptying intervals and therefore more convenience.
Automatic ash level indicationOnce the ash box is full, you are reminded on the display to empty it. When the warning appears the remaining space lasts for one more week. There should be no overfilling of the box and the boiler stays clean for years.
Induced draught fanAn ID-fan on the exhaust gas pipe ensures optimum air flow within the boiler, with theadvantages of providing the highest operating safety, independent of the natural chimney draught.
Low temperature boilerHargassner’s outside temperature measurement system allows the boiler's control unit to smoothly regulate the heat output. Boiler flow temperature, from 38°C to 75°C – with constant 95 % efficiency. Only the required energy is generated.
Heat exchanger with integrated back end protectionThe newly developed counter flow system within the compact tubular heat exchanger warms up the boiler return water (integrated back end protection) and results in a smooth operation.
Hargassner Boiler Technology
Hargassner guarantees highest efficiency by lowest emissions. Over 95% efficiency - tested and certified under strict conditionsHargassner stands for pioneering spirit and a wide range of experience. An excellent design and the highest quality construction provides the best functionality and optimal performance, resulting in high customer satisfaction and a long boiler lifetime.
Lambda sensor with fuel-quality detectionThe Lambda sensor regulates exactly the right quantity of fuel in every output range according to the pellet quality. This is the only way to guarantee an optimum (i.e. economical and low-emission) combustion that can save energy and money with more than 95% efficiency.
15
Effic
iency above
Pellet-Boile
rs
95
8
9
18
13
3
4
10
11
12
14
15
1
26
7
5
5
9
01 Fully refractory-lined combustion chamber02 Sliding grate03 Drive motor for sliding grate04 Secondary air flow05 High temperature resistant insulation plates06 Primary air07 Ash box08 Automatic ignition (300 W only)09 Stoker auger10 Circulation zone11 Boiler heat exchanger12 Turbulators13 Automatic boiler cleaning system14 Induced draught fan15 Cover insulation16 Pellets vacuum turbine17 Closed vacuum system, maintenance-free,
no filter18 Level detector19 Cyclone hopper20 Double rotary valve21 Motor drive unit22 Lambda sensor
Pellet suction up to 20mThe Hargassner pellet vacuum turbine sucks the pellets into the hopper; either from an extracting auger, a single, double, three or four-point vacuum feeding system, or a bag silo. A hose length up to 20m makes it easy to overcome architectural barriers and handle complex boiler and storage room combinations. To turn off the vacuum turbine after refill-ing the hopper, a level detector is integrated.
Pellet consumption displayWhen the minimum amount of pellets in the fuel storage room is reached, a warning is shown on the display.
Fully automatic boiler cleaning systemHargassner heating technology now brings you even more convenience. The ash removal system cleans the boiler at regular intervals. The fly ash falls automatically down after the cleaning movements of the specially-constructed turbulators. Inside the ash box, all the ash is compacted to a quarter of its original volume – thereby saving space and lengthening the emptying interval.
HSV 9 - 22 kW
Pellet Boiler with direct auger connection RADThe connection of the RAD-auger to the boiler takes place through a fully adjustable ball coupling. The extraction auger conveys the pellets via a small storage area into the newly developed double rotary valve. To reduce energy consumption a level detector is installed in the storage area.
After passing the double rotary valve, the pellets are transported by the stoker auger directly into the combustion chamber.
01 Room extraction auger02 Ball coupling03 Small storage with level detector04 Double rotary valve05 Stoker auger
Type Heat Output kW
HSV 9 2.8-9.5
HSV 12 3.5-12
HSV 14 4-14.9
HSV 15 4.5-16.8
HSV 22 6.5-22
Weight 300 kg
Voltage 230 V
Dimensions H x B x D [mm] 1470 x 1165 x 825
Excerpt from certified test reports
HSV 15 Nominal Output Partial Output Nominal Output Partial Output
Output kW 15.5 5 16.1 4.7
Boiler temp. °C 70 70 38 38
Efficiency % 94.3 93.2 96.3 93.7
Carbon dioxide % 15.1 12 15.2 11.2
Carbon monoxide mg/MJ 18 26 22 35
Dust mg/MJ 9 n.g. 6 n.g.
From the hopper into the double rotary valveHargassner’s new double rotary valve guarantees a 100% burn-back protection. A constant amount of pellets fall through the valves and the stoker auger transports the pellets into the refractory-lined combustion chamber.
AUSTRIA
EXPLANATION
NEW
16
19
20
21
17
01
0203
0405
10
Hargassner Boiler Technology
Circulation zone for best burn-outAirbourne particles from the combustion chamber end in a circling stream of gas before fully burning out.
Fully refractory-lined high temperature combustion chamber
Refractory has proven itself as the best material available in terms of heat storage, function and durability. The high combustion chamber temperature contributes to a high level combustion and over 93 % efficiency at full and partial load.
Automatic sliding grateThe well-engineered sliding grate system of Hargassner’s pellet boilers cleans itself fully automatically and combustion residues end up in the ash box. Primary air is consistently blown in via the grate and the ignition takes place automatically by a hot-air fan. Optimum afterburning and excellent emission values are guaranteed by pre-heated secondary air.
Ash box with integrated compressionA distribution mechanism mounted below the moving sliding grate ensures that the ash will be compressed and filled to the top of the box. This leads to extended emptying intervals and therefore more convenience.
Induced draught fanAn ID-fan on the exhaust gas pipe ensures optimum air flow within the boiler, with theadvantage of providing the highest operating safety, independent of the natural chimney draught.
Hargassner Classic Pellet Heating for small heating outputHargassner stands for pioneering spirit and a wide range of experience. An excellent design and the highest quality construction provides the best functionality and optimal performance, resulting in high customer satisfaction and a long boiler lifetime.
Latest Boiler TechnologyHargassner’s outside temperature measurement system allows the boiler‘s control unit to smoothly regulate the heat output. The boiler temperature will be adjusted to the current requirements. Only the required energy is generated.
Heat exchanger with integrated back end protectionThe newly developed counter flow system within the compact tubular heat exchanger warms up the boiler return water (integrated back end protection) and results in smooth operation.
Effic
iency above
Pellet-Boile
rs
93
Automatic ash level indication
Once the ash box is full, you are reminded on the display to empty it. When the warning appears the remaining space lasts for one more week. There should be no overfilling of the box and the boiler stays clean for years.
Lambda sensor with fuel-quality detectionThe Lambda sensor regulates exactly the right quantity of fuel in every output range according to the pellet quality. This is the only way to guarantee an optimum (i.e. economical and low-emission) combustion that can save energy and money with more than 93% efficiency.
8
9
18
13
3
4
10
11
12
14
15
1
26
7
5
11
Classic 9 - 22 kW
Type Heat Output kW
Classic 9 2.8-9.5Classic 12 3.5-12Classic 14 4-14.9Classic 15 4.5-16.8Classic 22 6.5-22
Weight 300 kg
Voltage 230 V
Dimensions H x B x D [mm] 1470 x 1165 x 775
01 Fully refractory-lined combustion chamber02 Sliding grate03 Drive motor for sliding grate04 Secondary air flow05 High temperature resistant insulation plates06 Primary air07 Ash box08 Automatic ignition (300 W only)09 Stoker auger10 Circulation zone11 Boiler heat exchanger12 Turbulators13 Automatic boiler cleaning system14 Induced draught fan15 Cover insulation16 Pellets vacuum turbine17 Closed vacuum system, maintenance-free,
no filter18 Level detector19 Cyclone hopper20 Double rotary valve21 Motor drive unit
Optional: Lambda sensor
Excerpt from certified test reportsClassic 12 Nominal Output Partial Output
Output kW 12.4 2.7
Boiler temp. °C 70 70
Efficiency % 93.6 90.4
Carbon dioxide % 13.7 7.1
Carbon monoxide mg/MJ 45 31
Dust mg/MJ 11 n.g.
Pellet suction up to 20mThe Hargassner pellet vacuum turbine sucks the pellets into the hopper; either from an extracting auger, a single, double, three or four-point vacuum feeding system, or a bag silo. A hose length up to 20m makes it easy to overcome architectural barriers and handle complex boiler and storage room combinations. To turn off the vacuum turbine after refilling the hopper, a level detector is integrated.
Fully automatic boiler cleaning systemHargassner heating technology now brings you even more convenience. The ash removal system cleans the boiler at regular intervals. The fly ash falls automatically down after the cleaning movement by specially-constructed turbulators. Inside the ash box, all the ash is compacted to a quarter of its original volume – thereby saving space and lengthening the emptying interval.
Pellet Boiler with direct auger connection RADThe connection of the RAD-auger to the boiler takes place through a fully adjustable ball coupling. The extraction auger conveys the pellets via a small storage area into the newly developed double rotary valve. To reduce energy consumption a level detector is installed in the storage area.
After passing the double rotary valve, the pellets are transported by the stoker auger directly into the combustion chamber.
From the hopper into the double rotary valveHargassner’s new double rotary valve guarantees a 100% burn-back protection. A constant amount of pellets fall through the valves and the stoker auger transports the pellets into the refractory-lined combustion chamber.
AUSTRIA
EXPLANATION
01 Room extraction auger02 Ball coupling03 Small storage with level detector04 Double rotary valve05 Stoker auger
Pellet consumption displayWhen the minimum amount of pellets in the fuel storage room is reached, a warning is shown on the display.
NEW
16
19
20
21
17
1
23
45
12
Hargassner – Advanced pellet heating for medium heating outputHargassner stands for pioneering spirit and a wide range of experience. An excellent design and the highest quality construction provides the best functionality and optimal performance, resulting in high customer satisfaction and a long boiler lifetime.
Ash box with integrated compressionThe ash extracting auger transports the fly ash and also the sliding grate ash into the ash box. On the way to the ash box, all the ash is compacted to a quarter of its volume – thereby saving space and lengthening emptying intervals.
3-path heat exchanger including fly ash separatorYears of experience have taught us that the flames of a wood fire must not be disturbed. In the Hargassner heat exchanger, the large burnout zone ensures an uninterrupted combustion process. Following this, the hot flue gases stream through one down-flow and one up-flow channel, including a fly ash separator.
Pellet suction up to 20mThe Hargassner pellet vacuum turbine sucks the pellets into the hopper; either from an extracting auger, a single, double, three or four-point vacuum feeding system, or a bag silo. A hose length up to 20m makes it easy to overcome architectural barriers and handle complex boiler and storage room combinations. To turn off the vacuum turbine after refilling the hopper, a level detector is integrated.
Fully refractory-lined high-temperature combustion chamber
Refractory has proven itself as the best material available in terms of heat storage, function and durability. The high combustion chamber temperature contributes to a high level combustion and high efficiency at full and partial load.
Automatic sliding grateThe well-engineered sliding grate system of Hargassner’s pellet boilers cleans itself fully automatically and combustion residues end up in the ash box. Primary air is consistently blown in via the grate and the ignition takes place automatically by a hot-air fan. Optimum afterburning and excellent emission values are guaranteed by pre-heated secondary air.
Automatic ash level indicationOnce the ash box is full, you are reminded on the display to empty it. When the warning appears the remaining space lasts for one more week. There should be no overfilling of the box and the boiler stays clean for years.
Induced draught fanAn ID-fan on the exhaust gas pipe ensures optimum air flow within the boiler.System advantage: Highest operating safety – independent of the natural chimney draught.
Latest Boiler TechnologyHargassner’s outside temperature measurement system allows the boiler‘s control unit to smoothly regulate the heat output. The boiler temperature will be adjusted to the current requirements. Only the required energy is generated.
Lambda sensor with fuel-quality detectionThe Lambda sensor regulates exactly the right quantity of fuel in every output range according to the pellet quality. This is the only way to guarantee an optimum (i.e. economical and low-emission) combustion that can save energy and money with more than 93% efficiency.
Effic
iency above
Pellet-Boile
rs
93
Hargassner Boiler Technology
20
8
9
1
3
4
6
10
11
13
1617
2
13
Classic Lambda 25 - 60 kW
01 Fully refractory-lined combustion chamber02 Sliding grate03 Drive motor for sliding grate04 Secondary air flow05 Fly ash separation06 Primary air07 Ash extraction08 Automatic ignition09 Stoker auger10 Circulation zone11 Automatic boiler cleaning system12 Induced draught fan13 Cover insulation14 Pellets vacuum turbine15 Closed vacuum system, maintenance-free,
no filter16 Level detector17 Cyclone hopper18 Double rotary valve19 Motor drive unit20 Lambda sensor
From the hopper into the double rotary valveHargassner’s new double rotary valve guarantees a 100% burn-back protection. A constant amount of pellets fall through the valves and the stoker auger transports the pellets into the refractory-lined combustion chamber.
Fully automatic boiler cleaning systemHargassner heating technology now brings you even more convenience. The ash removal system cleans the boiler at regular intervals. The fly ash falls automatically down after the cleaning movements of the specially-constructed turbulators. Inside the ash box, all the ash is compacted to a quarter of its volume – thereby saving space and lengthening the emptying interval.
Type Heat Output kWClassic L 25 7-25
Classic L 31 9-31
Classic L 35 10-35
Classic L 40 12-42
Classic L 49 14-48
Classic L 60 17-58
Weight 480 kg (430 kg)
Voltage 230 V
Dimensions H x B x D [mm] 1480 x 1210 x 1290
Values in () are for Cl 25-35
Excerpt from certified test reportsClassic L 40 Nominal Output Partial Output
Output kW 41.6 12.3
Boiler temp. °C 70 70
Efficiency % 95.7 93.8
Carbon dioxide % 16.4 10.1
Carbon monoxide mg/MJ 21 56
Dust mg/MJ 14 14
Pellet Boiler with direct auger connection RAD
The connection of the RAD-auger to the boiler takes place through a fully adjustable ball coupling. The extraction auger conveys the pellets
via a small storage area into the newly developed double rotary valve. To reduce energy consumption a level detector
is installed in the storage area.
AUSTRIA
EXPLANATION
Pellet consumption displayWhen the minimum amount of pellets in the fuel storage room is reached, a warning is shown on the display.
20
19
18
5 7
12
1415
1517
14
Energy-saving ignitionDue to the new design of the ignition element, electrical power consumption has been reduced to just 300 W (up to 1000 W less) and, at the same time, the efficiency of the ignition process has been increased.
- Electricity savings of over 88 % - Intelligent ignition monitoring - Completely silent
Full refractory-lined combustion chamberwith flame concentration jets for optimum post-combustionThe refractory combustion chamber guarantees high combustion temperatures by optimum heat storage (even at part-load), minimises the ignition procedure and reduces emissions.
Firebed monitoringThrough the precise and contactless firebed-height monitoring system, the most effective combustion conditions (depending on fuel quality) are detected. Your heating system is always working at optimum combustion values for the required heat output.
5
Perfect cleaning increases efficiencyThe new cleaning method cleans ALL heat exchanger tubes at regular intervals - NOW the down draught is also cleaned (Stainless steel turbulators). The heat ex-changer is cleaned with turbulators made out of heat-resistant material.
The turbulators remove the fly ash from the pipes, which falls down into the ash extraction auger. The result is easier cleaning and increased overall efficiency.
Unique double rotary step grateThe grate consists of two adjacent stepped grates which can be moved independently. As a result, wood pellets may be burned efficiently.
If regular wood pellets are used, only the rear de-ash grate opens. The ash falls down and the embers remain.
If the boiler is completely cold, a full cleaning process is executed. Both grates rotate and all foreign objects, such as stones, nails, etc. are removed in addition to the cold ash.
Energy-saving OperationSpeed-controlled EC exhaust fan with negative pressure monitoringFor the ECO-PK Hargassner uses energy-efficient EC exhaust fans. The main advantage of this GreenTech EC technology is the significantly higher efficiency rate of up to 90 %. This saves energy and electricity. The negative-pressure unit constantly measures the pressure conditions in the combustion chamber. The Lambda Touchtronic uses this data to control the speed of the draught fan, thus keeping the negative pressure at an ideal level. This concept ensures combustion with minimal exhaust gas temperatures and therefore maximum efficiency.
NEW Integrated Touch ControlThe all new Lambda Touchtronic is the ultimate control system which is exceptionally well designed and easy to use. You instantly see the current status of the boiler, the accumulator and the HWS, as well as all heating circuits. The new remote controls with LCD or touch displays make it even easier to use.
2
Effic
iency above
Pellet-Boile
rs
95
Hargassner Boiler Technology
1
2
13
10
4
11
12
9
15
Recirculation to reduce clinker
To reduce clinker in the ash, Hargassner offers flue gas recirculation as standard.Due to the cooling of the firebed during combustion, the relatively low ash melting point of very dry material can be reduced. The ash can be easily removed into the ash extraction auger.
ECO-PK 70 -120 kW
Pellet suction process also possible during combustionThe double rotary valve with ventilation allows refilling during the regular combustion process which means no loss of power and therefore optimum heat supply.
Pellet suction up to 20mThe Hargassner pellet vacuum turbine sucks the pellets into the hopper; either from an extracting auger, a single, double, three or four point vacuum feeding system, or a bag silo. A hose length of up to 20 m makes it easy to overcome architectural barriers and handle complex boiler and storage room combinations. To turn off the vacuum turbine after refilling the hopper, a level detector is integrated.
From the hopper into the double rotary valveA constant amount of pellets fall through the double rotary valve and the stoker auger transports the pellets into the refractory-lined combustion chamber.
NEW
NEWPellet consumption displayA warning is shown if the storage volume drops below a set value.
8
01 New grate system "Double rotary step grate"
02 Firebed levelling 03 Heat exchanger cleaning
(also in 1. draught)04 Ash suction system for longer
maintenance intervals, optional05 New ignition: 300 W, without fan06 Innovative integrated Touch control 07 Exhaust fan (EC-motor) with negative
pressure monitoring08 Recirculation - standard09 Optional: Integrated back end
protection10 Patented ash extraction for fly and
grate ash11 No thermal discharge safety device
necessary12 Combustion chamber fully integrated
in heat exchanger13 Flame concentration jets out of
high-end steel cast14 Cyclone Pellet Storage15 Closed suction system -
maintenance-free, without filter16 Fuel indicator17 Stoker auger18 Double-rotary valve with pressure
balance19 Drive unit20 Pellet Vacuum turbine21 Acoustic insulation
EXPLANATION
04
The all new ash suction system results in annual maintenance intervals
Optionally, a 300 litre ash bin is available. The suction system transports the ash through a steel pipe system from the boiler room into the ash bin, which is located in a roofed outdoor area. With a tractor or front loader, the ash bin may be emptied once a year. Hargassner provides best ease of use - with superior and smart cleaning technology.
10
8
1
3
5
6
7
NEWas standard
Type Heat Output kWEco-PK 70 20 - 70
Eco-PK 90 27 - 90
Eco-PK 100 30 - 99
Eco-PK 110 33 - 110
Eco-PK 120 36 - 120
Weight 865 (890)
Voltage 400 V
Dimensions H x B x D [mm]
1610 x 1430 x 1235
Values in () are for Eco-PK 100-120
Excerpt from certified test reportsEco-PK 120 Nominal Output Partial Output
Output kW 120.6 35.2
Efficiency % 93.3 95.4
Nitrogen oxide mg/MJ 71.0 50.0
Carbon monoxide mg/MJ 2 20
Dust mg/MJ 6 10
AUSTRIA
14
20
21
18
19
15
16
17
16
Hargassner Boiler Technology
Lambda sensor with fuel-quality detectionThe Lambda sensor regulates exactly the right quantity of fuel in every output range according to the pellet quality. This is the only way to guarantee an optimum (i.e. economical and low emission) combustion that can save energy and money with more than 93 % efficiency.
Speed-controlled induced draught fan with negative pressure regulationThe negative-pressure unit constantly measures the pressure conditions in the combustion chamber. The Lambda-Hatronic uses this data to control the speed of the draught fan, thus keeping the negative pressure at an ideal level. This concept ensures combustion with minimal exhaust gas temperatures and therefore maximum efficiency. This fan ensures the highest operating safety – independent of the natural chimney draught.
Hargassner – Advanced pellet heating for large heating outputHargassner stands for pioneering spirit and a wide range of experience. An excellent design and the highest quality construction provides the best functionality and optimal performance, resulting in high customer satisfaction and a long boiler lifetime.
Step grate for best combustionOptimum combustion is guaranteed through our large-scale grate area includ-ing 3 steps with separately controllable sliding and de-ash grates. Highly heat resistant grate bars with dedicated air nozzling and self-cleaning effect ensure a longer lifetime of the boiler. Consequently, the grate cleans itself fully automatically and at the same time the ash residues are delivered to the ash extract auger.
8
Latest Boiler TechnologyHargassner’s outside temperature measurement system allows the boiler‘s control unit to smoothly regulate the heating output. The boiler temperature will be adjusted to the current requirements. Only the required energy is generated.
3-path heat exchanger including fly ash separatorYears of experience have taught us that the flames of a wood fire must not be disturbed. In the Hargassner heat exchanger, the large burnout zone ensures an uninterrupted combustion process. Following this, the hot flue gases stream through one down-flow and one up-flow channel, including a fly ash separator.
Heat exchanger cleaning systemGone are the days when you have to clean the boiler. The control unit manages our fully automatic heat exchanger cleaning device. Depending on the heating times programmed, the system automatically switches on. The turbulators remove fly ash from the pipes, which directly falls down onto the ash extraction auger.
Fully refractory-lined high performance combustion chamber with double vault & turbo concentration bricks for optimum post-combustionRefractory has proven itself as the optimum material available in terms of heat storage, func-tion and durability. Fewer ignitions and optimum combustion – also at partial load – are the results. Optimum afterburning is guaranteed by our special twin chamber and boiler throat. Primary air is consistently blown in via the grate and the ignition takes place automatically by a hot-air fan. The massive heat-resistant combustion chamber – including outside air cooling system and speed-controlled pre-heated secondary air fed in over three levels – results in our industrial boiler having the lowest emission values. (Certified in Austria)
Spiral flow pushIn order to use the energy obtained to its full potential, we use turbulators to force the heated air into an elongated spiral flow path as near as possible to the heat exchanger.
Flue gas cyclone – Fly ash separator option: for flue gas purification when there is a large amount of fine material
Effic
iency above
Pellet-Boile
rs
93
9
11
17
1
2
14
5
18
21
20
19
15
17
01 Fully refractory-lined stoker02 Boiler heat exchanger03 Turbulators04 Fly ash separation05 Flue pipe outlet06 Lambda sensor07 Speed-controlled induced draught fan08 Negative pressure control09 Twin chamber including boiler throat10 Drive motor for ash extraction11 Fly ash and grate ash extraction auger12 Ash box13 Automatic boiler cleaning system14 Heat exchanger for thermal discharge
safety device15 Combustion air draught fan16 Primary air17 Secondary air18 Automatic ignition19 Stoker auger20 Sliding grate21 De-ashing grate22 Motor sliding grate23 Motor de-ashing grat24 Step feeding grate25 Fly ash agitator26 Motor fly ash agitator27 Cyclone hopper28 Closed vacuum system,
maintenance-free, no filter29 Level detector30 2 double rotary valves with ventilation31 Pellets vacuum turbine
WTH 150 - 200 kW
Type Heat Output kW
WTH 150 44-149WTH 200 59-199
Weight 2250 kg (2050 kg)
Voltage 400 V
Dimensions HxBxD [mm]2010 x 1890 x 1670(1910 x 1890 x 1500)
Values in () are for WTH 150
Excerpt from certified test reportsWTH 200 Pellets
OutputkW
Output%
Nitrogen oxideNOx %
Carbon monoxideCO mg/MJ
Dustmg/MJ
198 93.5 76 2 956.9 94.7 48 <2 8
Fully automatic boiler cleaning system and ash removalHargassner heating technology now brings you even more convenience. The ash removal system cleans the boiler at regular intervals. The fly ash falls automatically down after the cleaning movements of the specially-constructed turbulators. Inside the ash box, all the ash is compacted to a quarter of its original volume – thereby saving space and lengthen-ing the emptying interval.
From the hopper into the double rotary valveHargassner’s new double rotary valve guarantees a 100% burn-back protection. A constant amount of pellets fall through the double rotary valve and the stoker auger transports the pellets into the refractory-lined combustion chamber.
Pellet suction process during combustionThe double rotary valve with ventilation allows refilling during the regular combustion process meaning no loss of power and therefore optimum heat supply.
Pellet suction up to 20mThe Hargassner pellet vacuum turbine sucks the pellets into the hopper; either from an extracting auger, a single, double, three or four-point vacuum feeding system, or a bag silo. A hose length up to 20 m makes it easy to overcome architectural barriers and handle complex boiler and storage room combinations. To turn off the vacuum turbine after refilling the hopper, a level detector is integrated.
Pellet consumption displayWhen the minimum amount of pellets in the fuel storage room is reached, a warning is shown on the display.
Ash bin with diagonal ash removal augerLonger emptying intervals for even more convenience with Hargassner‘s diagonal ash removal auger – including a 300 l ash bin – customers experience even more convenience.
OPTIONAL
AUSTRIA
27
22
30
28
28
31
294
7
11
16
2425
23
12
13
26
10
3
18
Intelligent use of residual heat
Day reductionHeating Heating Intelligent use of residual heat
Night reduction
6 a.m. - 9 a.m. 9 a.m. - 3 p.m. 3 p.m. - 10 p.m. 10 p.m. - 6 a.m.
Combustion
Boiler 78o Smoke 175o
HC1 60o HC2 52o
HWS 1 55o Outs. -7o
We, 18. 02. 2009 7:03
Combustion
Boiler 68o Smoke 160o
HC1 42o HC2 38o
HWS 1 50o Outs. -1o
We, 18. 02. 2009 11:43
Combustion
Boiler 73o Smoke 170o
HC1 52o HC2 45o
HWS 1 60o Outs. 1o
We, 18. 02. 2009 18:33
Heating OFF
Boiler 39o Smoke 50o
HC1 00o HC2 00o
HWS 1 58o Outs. -2o
Th, 19. 02. 2009 3:18
Intelligent use of residual heat
Day reductionHeating Heating Intelligent use of residual heat
Night reduction
6 a.m. - 9 a.m. 9 a.m. - 3 p.m. 3 p.m. - 10 p.m. 10 p.m. - 6 a.m.
Combustion
Boiler 78o Smoke 175o
HC1 60o HC2 52o
HWS 1 55o Outs. -7o
We, 18. 02. 2009 7:03
Combustion
Boiler 68o Smoke 160o
HC1 42o HC2 38o
HWS 1 50o Outs. -1o
We, 18. 02. 2009 11:43
Combustion
Boiler 73o Smoke 170o
HC1 52o HC2 45o
HWS 1 60o Outs. 1o
We, 18. 02. 2009 18:33
Heating OFF
Boiler 39o Smoke 50o
HC1 00o HC2 00o
HWS 1 58o Outs. -2o
Th, 19. 02. 2009 3:18
Boiler prior to commissioning: The display of the Lambda Touchtronic shows an unheated wood log boiler. The accumulator and the hot water tank are cold.
Boiler full load: The display shows a boiler in operation. The accumu-lator and the hot water tank are being loaded and are already increasing temperature. The heating circuit pumps are on.
Boiler partial load: The boiler runs on half of its nominal heating output. The accumulator and hot water tank are completely loaded. The heating circuit pumps are on.
Hot-water storageIt is only necessary to set the desired hot water tank temperature and charging time. Your control unit will take care of the remaining steps automatically.
The minimum temperature control for the hot water system is a useful feature. The Lambda Touchtronic reacts immediately when the temperature of the hot water drops below the minimum temperature outside the programmed heating time. Advantage for you: hot water 24 hours a day.
The hot water system is heated according to prioritsation rules: traditionally, there is only one type of hot water system regulation: the domestic hot water system is cold, the heating circuit is switched off. Hargassner will never leave you out in the cold. If the water is cold, the heating is only reduced temporarily and the heating elements remain warm; there is no reduction in room temperature.
Control of the heating circuits ✔ The Lambda Touchtronic can control several independent heating
circuits. The client is able to define different settings in detail; e.g. indoor room temperature on all heating circuits, depending on time of day and outside temperature.
✔ Hargassner’s 3G day/night reduction mode enables the client to set 3 thresholds. One mode for ‘Heating during the day’, one for ‘Reduction during the day’ and one for ‘Reduction during the night’. As a result, the heating system only operates if necessary. This saves energy without sacrificing comfort.
✔ Through the ingenious residual heat use programme, the remaining energy in the boiler is used efficiently after the shutdown of the boiler.
Heating Time 1:6 a.m. - 9 a.m.Outside it is -7°C, so considerably less than the threshold value of +16°C - the heating switches on.
Day-reduced temperature: 9 a.m. - 3 p.m.Outside temperature increases to -1°C consid-erably less than the day time reduced tempera-ture threshold of +8°C. Heating day-reduced temperature operation.
Night-reduced temperature: 10 p.m. - 6 a.m.The temperature cools to -2°C, so above the threshold value for the night-reduced tem-perature of -5°C. The heating switches off.
Heating Time 2: 3 p.m. - 10 p.m.The outside tempera-ture climbs to +1°C; so considerably less than the threshold value of +16°C. The heating remains switched on.
Hargassner Control UnitLambda Sensor with
automatic fuel quality detection
Sit back and relax – your heating system is doing the work for youThe Lambda Touchtronic has a userfriendly touch screen. The system controls the complete combustion process, the back end protection and the loading of the accumulator. Furthermore, all heating circuits and hot water circuits can be regulated. The control works according to external conditions, recognising the changes in conditions as soon as they occur and adjusting the boiler output accordingly. Maximum comfort guaranteed.
19
PU
F FER
SO
L AR
HARG
ASSN
ER
FW
HARG
ASSN
ER
Ease of operation through Touchtronic
Accumulator Control Option (PSP)During start up, the control sends the heat through a fast loading valve directly to the heating demand areas. As soon as the boiler starts storing the energy into the accumulator tank, the operation mode changes to partial load. As a result, the combustion time is extended and the heating comfort is increased. Solar: To combine wood logs with solar, Hargassner developed a handy function for the Touchtronic => an automatic ignition. First the hot water stored in the tank from solar-energy is used, before the biomass boiler fires up using automatic ignition.
Controlling External Boilers If desired, an additional external boiler, e.g. pellet, oil or gas boiler, may be integrated. The change over between the two boilers occurs fully automatically.
Cascade controllerCascade controller for 2, 3 or 4 boilersAutomatic switch on or change over control of boilers, based on outside temperature. Priority mode, equality of operation hours possible, auto change-over mode after error.
A C C E S S O R I E S
Extension module HKMThis unit is used to add 2 additional heating circuits and 1 additional hot water tank (including circulation pump). Inclusion of 2 or more modules results in 4 additional heating circuits and 2 additional hot water systems.
Extension module HKM with Touch and CAN-BUS-SystemThis module is used to add 2 additional heating circuits and 1 additional hot water tank (including circulation pump), controlled via touch display. Additionally, an external heating circuit or a centralised accumulator and 1 HKM may be installed.
Heating circuit controller HKR with Touch and CAN-BUS-SystemControl unit based on atmospheric conditions with Touch control for 2 mixing valve-controlled heating circuits and 1 hot water tank circuit with circulation pump; 1 accumulator or external boiler, 1 external heating circuit, 1 long-distance heating or accumulator pump. Extension with max. 2 HKM (max. 8 HKR). SD-card Slot and data logging.
VisualisationVisualisation of the boiler, weekly overview, parameter display, fault display, temperature and parameter monitoring and recording. Remote access for maintenance is possible via Internet.
Additional control board AThis control board is to control 1 heat circuit and 1 HWS. the board may be integrated in the boiler, the extension module HKM or the heat circuit controller HKR.
Remote ControlsApp: With the all new Hargassner APP you can easily change heating times, temperatures and operation modes and receive information regarding the current boiler status. These messages can be sent via email or push notification to your mobile.
Analog FR 25: This remote control measures the actual internal temperature, and can also apply corrections to the control unit. You can use the temperature controller to adjust the room temperature up or down. With or without room-temperature dependence. A warning light is integrated to inform the client about the status of the heating system.
LCD FR 35: Remote control FR 35 with LCD-Display: For setting the room temperature and/or daytime reduction or heating operation. With or without room-temperature dependence. Dis-play of room, outside and DHW temperature. Only for Touch-Control
Radio version option for LCD FR 35 FR35 Radio version transmitter with LCD-Display, radio broadcasting module for max. 6 receivers, LCD-Display for easy pro-gramming. If simultaneously used as a room-tempera-ture device, several functions of the FR35 may be used. BUS-connection to the boiler or HKR required. Only for Touch-Control
Touch remote control FR 40: set the room temperature, change heating status, change heating temperatures and times. All functions of the boiler are controllable from your living room.
SMS: With this special tool you can have your heating under control even when you are not at home. Faults are automatically sent to your mobile and you can issue commands to the controller, e.g. switch the heating circuits on or off or set new temperatures, all from your mobile with complete reliability.
+
NEW
NEW:APPREMOTE CONTROL FOR
YOUR HEATINGSYSTEM
20
Single or double containers from 4 to 6 metres. The new heating solution: Boiler room and fuel storage room in one.
Hargassner Fuel Storage
Extraction RAS
Heating modules Eco Box
This auger-suction combination is used for large or elongated storage rooms. Distances up to 30 m from the boiler room to the storage room can be overcome.
Extraction RAPSPure suction system; used for small and ideally square storage rooms. For larger rooms three or four-point suction systems are available, either with manual or auto suction changeover unit.
Up to 17m² EXTRA SPACE
NEW –
AUTO CHANGEOVER
FOR 2 RAS
21
Storage room – SizeCalculate the storage room as follows: Building heating load in:kW x 0.90 = Storage size in m³kW x 0.40 = Pellets requirement in tonnes
Example: A single house with a calculated heating load of 15kW needs, according to the formula, 13.50 m³. Room size: 2 x 3 x 2.2m (l x b x h).Because of the storage volume, you are able to buy pellets when they are the least expensive.
Installation:The pellet fill truck is equipped with a 50 m filling tube. The storage room may be up to 20 m away from the boiler room.
Storage room – RequirementsTo prevent swelling, the pellet storage room should be as dry as possible. Electrical installation is prohibited and water-carrying tubes should be avoided. To install the room extraction system and ensure maximum fire protection, a door has to be installed. Inside the door, Hargassner offers a door protection set to constantly monitor the pellet level.
Available in 8 or 10 m³.
Pellet storage room requirements:
Pellet boiler with external storage Pellet boiler with integrated fuel storage for manual refill with bags
Underground Pellet Tank
Pellet boiler with an external weekly storage bin (out of steel, incl. point suction system), 770 litres volume, or 500 kg pellets, Dimensions: 770 x 1150 x 1090 mm to be filled with bags
for Pellet Classic Touch 9-22 kW, with integrated storage, 185 litres filling volume, or 120 kg pellets, level indicator, to be filled with bags
Extraction RAD
Extraction GWTSHargassner’s bag silo represents a complete storage room solution. The silo can be placed inside or outside the boiler room (depending on building regulations).
This pure auger system delivers the pellets from the storage room directly into the stoker auger. For standard (optimum) storage room situations only.
NEW-
BAG SILO XXL
NEW
NEW
✔ 350 litres volume ✔ 230 kg pellets ✔ 540 x 580 x 1.340 mm
Nano-PK external weekly storage binNEW
22
Pellet boiler with RASRAS stands for “Room extraction Auger Suction”. This system is mostly used for large and elongated storage rooms. Distances up to 30m from the boiler room to the storage room can be overcome. The pellets are transported outside the storage room through the auger into the vacuum system. The special construction of the auger trough prevents overfilling and guarantees a constant delivery rate. As a result, the storage room will be emptied down to the last pellet. The storage room has to be equipped with a 35° sloping floor.
2 storage room extraction augers for one 2-point auto changeover unitFor large and square wood pellet storage rooms, 2 extraction augers are installed. The changeover from one to the other auger takes place through a 2-point auto changeover unit. The result is an optimum storage room extraction and an efficient way to use larger pellet volumes over longer distances.
Extraction RAS
1/4
1/2
1/4
T30: 80x200
Wall F90
min. 20 cm
2 x
Impa
ct p
rote
ctio
n m
ats
Auge
r len
gth
from
150
- 5
00 c
m
Auto-changeover unit 2-point
Top view
The storage room does not have to be next to the boiler room. Pellets can be transported up to 30m.
Draught stabaliser 2 x fire protection sleeves
Light shaft
Grounding terminal
Door with wooden boards
Wall break-through: 35cm breadth 25cm height
Load-carrying construction
35° wooden boards or shuttering panelsThickness ~ 28mm with an additional 4mm hard board on top
35°Fill socket enclosed or sealed (grounding terminal obligatory)
min.20 cm
2 x bent Pellet fill sockets:Tanker connection system: Storz A with blind cover, 45° bend and straight wall
tube Ø 11.5 x 50 11.5 cm x 50 cmmin. 20 cm
Front view
NEW
1/4
1/2
1/4
T30: 80x200
min. 20 cm
Wall F90
2 x
Impa
ct p
rote
ctio
n m
ats
Auge
r len
gth
from
von
150
- 5
00 c
m
2 x Fire protection sleeves
Top view
23
Extraction RAPS
RAPS Single Point
Manual changeover unit for double and triple position vacuum feeding system.
RAPS, Single position
Manual changeover unit RAPS, Double positionAuto changeover unit RAPS, Four positions
Front view
Front view Front view
Pellet boiler with RAPSThe RAPS-System is a pure suction system. Mostly used for small and ideally square storage rooms. The suction points are installed in the middle of the room and accommodate complex room situations. In order to unload large storage rooms, three and four-position vacuum feeding systems are available, optionally with manual or auto changeover unit. The storage room has to be equipped with a 35° sloping floor.
Auto changeover unit for double, three or four-position vacuum feeding system.
24
Pellet boiler with GWTS XXLThe bag silo XXL is made of a static steel construction with an elastic floor element, including tension springs. If refilled, the springs get extended and the silo is filled to a maximum. Because of the steady emptying, the elastic construction gets pulled up, and after emptying the silo looks like a four-sided sloping floor. The bottom of the silo is water-resistant.
Extraction GWTS
Pellet boiler with GWTSHargassner’s bag silo represents a complete storage room solution. The silo can be placed (depending on building regulations) either inside or outside the boiler room. If installed outside, the silo has to have a stable floor and needs to be protected against UV-radiation and rain. Equipped with a single-position feeding system, the silo is made out of a special, high-quality, anti-static and dust-proof material. Because of this material, only one pellet fill socket is needed. Depending on the room height, the pellet fill socket can be installed above or below the easily assembled steel construction.
Type Capacity Width Depth Height
GWTS 160 x 160 2.0 - 2.5 t 168 cm 168 cm 195 - 250 cm
GWTS 200 x 200 2.7 - 3.6 t 208 cm 208 cm 195 - 250 cm
GWTS 200 x 250 3.3 - 4.3 t 208 cm 258 cm 195 - 250 cm
GWTS 250 x 250 4.0 - 5.3 t 258 cm 258 cm 195 - 250 cm
GWTS 250 x 250 XL 6.1 t 258 cm 258 cm 270 cm
Bag Silo (GWTS XXL)
Type Capacity Width Depth Height
GWTS 200x200 XXL 4.0 - 5.1 t 208 cm 208 cm 195 - 250 cm
GWTS 160x250 XXL 4.0 - 5.4 t 168 cm 258 cm 195 - 250 cm
GWTS 200x250 XXL 4.6 - 6.2 t 208 cm 258 cm 195 - 250 cm
GWTS 250x250 XXL 6.0 - 8.0 t 258 cm 258 cm 195 - 250 cm
Maximum Capacity
up to 8 tonnes Minimum dimensions
only 6m²
Bag Silo (GWTS)
Bag Silo (GWTS-XXL)
Front view
Room
hei
ght 1
95 –
250
cm
Pellets fill socket (above/below) Pellets fill socket (above/below)
Bag Silo (GWTS)
Room
hei
ght 1
95 -
250
cm
Front view
25
Extraction RADUnderground Pellet
Tank - PET
Extraction RADThe RAD, pure auger system, delivers the pellets from the storage room directly into the stoker auger. For standard (optimum) storage room situations only. The storage room has to be equipped with a 35° sloping floor.
Underground Pellet Tank - PETAnother possibility for wood pellet storage is spherical underground tanks made of corrosion-resistant, fiberglass-reinforced polyester resin GFK. Highest operation safety, through a special safety package with full explosion protection for the vessel, is guaranteed. The patented extrac-tion system consists of a base body, all necessary connections for the filling, as well as connections for the suction process. A well-engineered extraction system provides 100 % usage of the sphere volume. The underground tank can be placed in the garden or under a driveway. The covers are accessible by foot or optionally by car or truck.
Technical Data:Type PET 8 m3 10 m3
Filling volume t 5.2 6.5Diameter mm 2,500 2,680Weight kg 280 330ExcavationDiameter (min.) m 3.50 3.75Height (min.) m 3.60 3.85Fill material m3 19 22
für all typesAdvantages Operation save, 100% emptying
for ALL Hargassner pellet boilers
Point suction system
Suction hose
Suction hose
Underground Pellet Tank
Boiler room
Pellet boiler
Fuel
Fill socket
Grounding
Manhole pit
Protective pipe
Direct auger diagonal
Top view
min
. 50
cm
min. 20 cm
Pellet impact mat
Vent
ilatio
n so
cket
Pelle
ts fi
ll so
cket
(m
iddl
e)
2 x Pellet fill sockets bent:Tanker connection system: Storz A with blind cover, 45° bend and straight wall tube ø 11.5 x 50 cm, enclosed or sealed (grounding terminal obligatory)
T30: 80x90
Front view
The storage room has to be next to the boiler room.
Storage room length: 1.5 – 5mLight shaft
Grounding terminal
Fill socket enclosed or sealed (grounding termi-nal obligatory)
min. 20 cm
2 x Pellet fill sockets bent:Tanker connection system: Storz A
with blind cover, 45° bend and straight wall tube ø 11.5 x 50 cm
35° wooden boards or shuttering panelsThickness ca. 28mm with an additional 4mm hard board on top
Draught stabaliser
26
Single Pellet Container with pitched roof next to a home in Weng i. I., 12 kW Pellets
Hargassner Containers
Examples:
Technical data:
Type BC 400 BC 500 BC 600 BC 700 BC 800 BC 600Double Container
Length 400 cm 500 cm 600 cm 700 cm 800 cm 600 cm
Width 300 cm 300 cm 300 cm 300 cm 300 cm 300 cmHeight outside 265 cm 265 cm 265 cm 265 cm 265 cm 540 cmHeight inside 228 cm 228 cm 228 cm 228 cm 228 cm 490 cmAdditional height outside 308 cm / 320 cm
Additional height inside 266 cm / 280 cm
Weight ca. 17 t ca. 20 t ca. 25 t ca. 30 t ca. 33 t 23+16 t
Filling volume/mass
5 tPellets
8 tPellets
11 tPellets
14 tPellets
17.7 tPellets
ca. 32 t Pellets
Container – DetailsPrefabricated concrete walls REI 90 (F 90), wall thickness 13 cm, epoxy coating on floor, interior wiping resistant emulsion coating and exterior high quality spray render (2-3 mm granularity white)Containers include all openings for augers, ventilation, chimney, district heating connection, pellet fill sockets.
Auxiliary Equipment: Roof covering, dividing wall F 90, Steel door, Fire protection wall T30, Fuel storage door T30, Stainless steel chimney and additional openings.
Concrete Heating Containers – best combination of plant room and storage room
Containers are available in single, double or triple design, according to requirements. Because of the modular construction, our containers are easily positioned, assembled and installed. The main advantage is the enormous space and cost saving, either in new or refurbished buildings. Concrete containers are especially useful for public build-ings, industrial enterprises, hotels or shared housing communities. Because of the comparatively low investment costs, Hargassner’s containers are also perfectly suited for heat contracting businesses.
Single Container
Extra size on request
Social institution "Paulusstift" in Neuötting (D), 80 kW Pellets
Technical data Containers
Compact,space-saving
& uniquedesign
27
Cutaway Heating ContainerDouble Container
Apartment in Wörgl, 600 kW Pellets
Type ECO-BOX 550 ECO-BOX 600 ECO-BOX 700 ECO-BOX 750Length 550 cm 600 cm 700 cm 750 cmWidth 298 cm 298 cm 298 cm 298 cm Height outside 271 cm 271 cm 271 cm 271 cm
Height inside 232 cm 232 cm 232 cm 232 cmWidth ca. 15 t ca. 16.5 t ca. 18.5 t ca. 20 t
Decken-secktionaltor
Decken-secktionaltor
Technical data Eco-Box
Container Details Prefabricated concrete walls REI 90 (F 90), 3-layer roof covering, strengthened floor 10 t, wall thickness 13 cm, interior wipeable emulsion coating and exterior high quality spray render (2-3 mm granularity white). All containers include open-ings for augers, ventilation, chimney, district heating connection, pellet fill sockets...
Auxiliary Equipment Boiler room floor with high-quality epoxy coating, steel door, fire protective door T30, chimney extensions, windows and automatic door drive
Detatched house in Hall bei Admont, 9 kW Pellets
Up to 17m² EXTRA SPACE
Front door
Pellet Boiler Accessories
28
Impact protection mat To ensure best pellet quality, impact protection mats have to be installed opposite every socket.
Door protection set To relieve pressure on doors and enable a constant monitoring of the pellet level, Hargassner offers a special door protection set.
Load-carrying construction
Mounting clips
Fire protection sleeve
Z-section profiles, wooden boards, etc.
Pellet fill and ventilation sockets
A minimum of two sockets have to be installed in every storage room. One to fill and one to close the vacuum circuit. As a result, dustfree filling is guaranteed.
Sloping floor
To guarantee complete emptying of the storage room, Hargassner recommends a 35° wooden sloping floor. The sloping floor has to be provided on site.
Suction hose antistatic, abrasion-proof, copper grounding, reels 10, 25, and 50 rm
Mounting clips for suction hose including screw package
Carrying shell Suction hose connection ø 50 x 80mm, 2 pcs. screw terminals
Suction hose bow ø 50 x 90°, 2 pcs. screw terminals
Pellet fill socket straight A-clutch with ventilating cap, mounting flange, grounding screw, including clamp ring
Pellet fill socket - bent 45°, A-clutch with ventilating cap, mounting flange, grounding screw, including clamp ring
Set 1 for a small entry hatch: 2 pcs. of Z-rails Type 1, 1 panel with an inspection window and 4 pcs. wooden protection boards.
Set 2 for as standard door, with 2 pcs. of Z-rails Type 2, 1 panel with an inspection window and 9 pcs. wooden protection boards.
Z-rails Type 1 Length = 1000 mm, 2 pcs. for a small entry hatch (incl. fixing material)
Z-rails Type 2 Length = 2000 mm, 2 pcs. for a standard door (incl. fixing material)
Wooden protection board 1: 1000 x 200 x 27 mm, per piece
Inspection panel: 1000 x 250 x 27 mm, per piece
Extension tubes including clamp ring
Pipe elbows including clamp ring
Accumulators
29
Hygienic-layered Accumulator HSPThrough the integrated return spreading sheet, the variable sensor positioning and the hygienic drinking water heating process, this accumulator guarantees efficient usage. A stainless steel pipe enables hygienic and legionella-safe drinking water heating with a high hot water output. A regular movement of the stainless steel pipes provides best protection against scaling.
Solar-layered SP-SW and Solar-hygienic-layered Accumulator HSP-SW This solar-layered accumulator is perfectly designed for Hargassner control and hydraulic schemes. Besides the integrated return spreading sheet and a variable sensor positoning, the accumulator carries highly-efficient solar heat exchanger(s). Optionally, the accumulator is available with bottom (SW1) or bottom and top (SW2) solar heat exchanger.
Layered Accumulator SPThis layered accumulator is perfectly designed for Hargassner control and hydraulic schemes. Through the integrated return spreading sheet, efficient accumulator usage is guaranteed. Integrated sensor strips enable easy and flexible installation and therefore optimize the hydraulic loading and unloading processes.
Layered Accumulator SP SP 825 SP 1000 SP 1500 SP 2000 SP 2600Accumulator volume Litre 825 1000 1500 2000 2600Diameter ø without insulation mm 750 790 1010 1100 1250Diameter ø with insulation mm 950 990 1200 1300 1490Height with insulation mm 1980 2090 2160 2320 2440
Hygienic-layered Accumulator HSP HSP 500 HSP 650 HSP 825 HSP 1000 HSP 1500 HSP 2000Accumulator volume Litre 500 650 825 1000 1500 2000Diameter ø without insulation mm 650 750 750 790 1010 1100Diameter ø with insulation mm 850 950 950 990 1200 1300Height without insulation mm 1630 1660 1910 2020 2090 2250Stainless steel pipe - water volume Litre 23 23 38 38 46 46
Solar-layered Accumulator SP SP 825 SP 1000 SP 1500 SP 2000Accumulator volume Litre 825 1000 1500 2000Diameter ø without insulation mm 750 790 1010 1100Diameter ø with insulation mm 950 990 1200 1300Height without insulation mm 1910 2020 2090 2250Solar heat exchanger bottom SW1 1" F m² 2 3 3 4Solar heat exchanger top/bottom SW2 1" F m² 2/2 2/3 3/3 4/4
Hygienic Solar-layered Accumulator HSP HSP 500(SW1 only)
HSP 650(SW1 only) HSP 825 HSP 1000 HSP 1500
Accumulator volume Litre 500 650 825 1000 1500Diameter ø without insulation mm 650 750 750 790 1010Diameter ø with insulation mm 850 950 950 990 1200Height without insulation mm 1630 1660 1910 2020 2090Height with insulation mm 1700 1730 1980 2090 2160Port 8 pcs. F Inch 5/4“ 5/4“ 5/4“ 5/4“ 5/4“Stainless steel pipe - water volume Litre 23 23 38 38 46Stainless steel corrugated pipe 5/4" M m² 4.1 4.1 7 7 8.6Weight SW1 (without insulation) kg 163 180 196 231 -Solar heat exchanger bottom SW1 1" F m² 2 2 2 3 -Weight SW2 (without insulation) kg - - 220 256 324Solar heat exchanger top/bottom SW2 1" F m² - - 2/2 2/3 3/3
Max. operating pressure 3 bar, max. operating temperature 95°C , max. tap water pressure 6 bar
(Attention: Numbers in bracketsfor WTH 150 Pellets boiler)
1165395 725
825130
115212
72
830
1470
7301065
190
570
1065
730 190
570
730 210
590
1110780 150
( Attention: Numbers in brackets for Type Classic-Lambda 25-35)
1310
(111
0)54
51470
(127
0)
980310
1210
1480
240
1165
395
1470
1152
108212
72
130 775
675
RL 1"
VL 1"
VL 1"RL 1"
RL 5/4"
VL 5/4"
130 bei 25-31kW150 bei 35-60kW
780
HeizkreisVL/RLHK 5/4"
Puffer/BoilerVL/RL Boiler 1"
580
84
135
0
160
0
100
715
1
165
405
95
RL 1"
VL 1"
1000 110
230
960 8901890
625
1260
(136
0)
1910
(201
0)
650
360 14
0
200 (250)
900
935
1000
(110
0)50
0
500 65020
15 (2
190)
1120
(122
0)
1574
(175
0)14
94 (1
670)
795
Dimensions and technical details
HSV 9 - 22 kW
Nano-PK 6 - 12
CLASSIC 9 - 22 kW
CLASSIC LAMBDA 25 - 60 kW
ECO PK 70 - 120
WTH 150 - 200 kW
30
for
hydr
aulic
sch
emes
ple
ase
ask
your
dis
trib
utio
n pa
rtne
r
31
Technical data: Nano-PK 6-12Nano-PK 6 Nano-PK 9 Nano-PK 12
Power range kW 1.6-6 2.7-9 1.6-12Efficiency (at nominal heat output) % 93.6 / 91.3 93.6-91.3 93.7 / 91.3Nominal heat output kW 6.4 9.6 12.8Flue pipe diameter mm 100 100 100Amount of water in heat exchanger Litre 24 24 24Boiler temperature range °C 48 - 70 48 - 70 48 - 70Back end protection temperature °C acc. heating scheme acc. heating scheme acc. heating schemeWater-side resistance ΔT 10 / 20 [K] mbar 5.33 / 2.25 8.4 / 3.8 11.6 / 5.3Flow / Return flow inch 1" 1" 1"Weight kg 220 220 220Boiler height H mm 1350 1350 1350Boiler width Suction/RAD W mm 780 780 780Boiler depth D mm 580 580 580Transporting Dimensions WidthTotal / disassembled Depth
W mm 1380 1380 1380D mm 580 580 580
Technical data: Eco PK 70-120Eco-PK 70 Eco-PK 90 Eco-PK 100 Eco-PK 110 Eco-PK 120
Power range kW 20-70 27-90 30-99 33-110 36-120Efficiency (at nominal heat output) % 94.6 / 95.3 94.1 / 95.3 93.8 / 95.4 93.6-95.4 93.3 / 95.4Nominal heat output kW 74.5 95.4 105 116.6 127.2Flue pipe diameter mm 180 180 180 180 180Amount of water in heat exchanger Litre 180 180 180 180 180Boiler temperature range °C 75-78 75-78 75-78 75-78 75-78Back end protection temperature °C 58 58 58 58 58Water-side resistance ΔT 10 / 20 [K] mbar 57.1 / 14.6 91.4 / 23.2 112.9 / 28.9 139.1 / 35.5 160.7 / 40.9Flow / Return flow Inch 6/4" 6/4" 6/4" 6/4" 6/4"
Thermo Valve connection Sensor
Inch - - - - -Inch - - - - -
Weight kg 865 865 890 890 890Boiler height H mm 1610 1610 1610 1610 1610Boiler width B mm 745 745 745 745 745Boiler depth T mm 1235 1235 1235 1235 1235
Transporting Dimensions Widthdisassembled Depth
B mm 745 745 745 745 745T mm 1335 1335 1335 1335 1335
min. room height Hr mm 2200 2200 2200 2200 2200Electrical supply - 400 V AC, 50 Hz, 13 A fuse
HSV WTH 150 - 200WTH 150 WTH 200 44-149 59-199
93.6 / 93.3 93.5 / 94.7159.5 214.0200 250410 505
75-80 75-8058 58
51.3 / 13.7 38.5 / 14.52" 2.5"
3/4" 3/4"1/2" 1/2"2050 22501910 20101890 18901500 1670888 8881470 16402500 2600400 V AC, 50 Hz, 16 A fuse
Technical data: Pellet Boiler Classic Lambda 25 - 60Classic 25 Classic 31 Classic 35 Classic 40 Classic 49 Classic 60
Power range kW 7-25 9-31 10-35 12-42 14-48 17-58Efficiency (at nominal heat output) % 95.1 / 93.1 94.5 / 93.1 94.1 / 93.1 94.3 / 94.3 94.3 / 94.3 94.6 / 93.8Nominal heat output kW 26.3 32.8 37.2 44.5 50.9 61.3Flue pipe diameter mm 130 130 150 150 150 150Amount of water in heat exchanger Litre 100 100 100 124 124 124Boiler temperature range °C 69-75 69-75 69-75 69-85 69-85 69-85Back end protection temperature °C 58 58 58 58 58 58Water-side resistance ΔT 10 / 20 [K] mbar 9.7 / 2.6 12 / 3.2 18.5 / 5 24 / 6.4 32 / 8.6 56.4 / 14.4Flow / Return flow inch 5/4" 5/4" 5/4" 5/4" 5/4" 5/4"Weight kg 430 430 430 480 480 480Boiler height H mm 1480 1480 1480 1480 1480 1480Boiler width Suction/RAD W mm 1210/1110 1210/1110 1210/1110 1210/1110 1210/1110 1210/1110Boiler depth D mm 1290 1290 1290 1290 1290 1290
Transporting Dimensions WidthTotal / disassembled Depth
W mm 1210/760 1210/760 1210/760 1210/760 1210/760 1210/760D mm 1290/800 1290/800 1290/800 1290/800 1290/800 1290/800
Technical data: Pellet Boiler Classic 9 - 22 / Pellet Boiler HSV 9 - 22Classic 9 HSV 9 Classic 12 HSV 12 Classic 14 HSV 14 Classic 15 HSV 15 Classic 22 HSV 22
Power range: kW 2.8-9.5 2.8-9.5 3.5-12 3.5-12 4-14.9 4-14.9 4.5-16.8 4.5-16.8 6.5-22 6.5-22Efficiency (at nominal heat output) % 94.2 / 92.4 94.2 / 92.4 93.6 / 90.4 93.8 / 91.9 93.1 / 91.9 92.8 / 90.9 92.7 / 92.4 96.3 / 93.7 91.9 / 94.6 94 / 93.4Nominal heat output kW 10.2 10.1 12.8 12.8 16.0 15.7 18.1 17.4 23.9 22.9Flue pipe diameter mm 130 130 130 130 130Amount of water in heat exchanger Litre 38 38 38 38 38Boiler temperature range °C 72-75 38-75 72-75 38-75 72-75 38-75 72-75 38-75 72-75 38-75Back end protection temperature °C integrated integrated integrated integrated integratedWater-side resistance ΔT 10 / 20 [K] mbar 4.1 / 1.3 6.2 / 2.2 7.2 / 2.3 7.7 / 2.5 18.3 / 3.8Flow / Return flow inch 1" 1" 1" 1" 1"Weight kg 300 300 300 300 300Boiler height H mm 1470 1470 1470 1470 1470Boiler width Suction/RAD W mm 1165/1065 1165/1065 1165/1065 1165/1065 1165/1065Boiler depth D mm 775 825 775 825 775 825 775 825 775 825
Transporting Dimensions WidthTotal / disassembled Depth
W mm 1165 / 730 1165 / 730 1165 / 730 1165 / 730 1165 / 730D mm 775 / 670 825 / 670 775 / 670 825 / 670 775 / 670 825 / 670 775 / 670 825 / 670 775 / 670 825 / 670
Max. operating temperature: 95 °C, Max. operating pressure: 3 bar, Electrical supply: 230 V AC, 50 Hz, 13 A fuse
Max. operating temperature: 95 °C, Max. operating pressure: 3 bar, Electrical supply: 230 V AC, 50 Hz, 13 A fuse
Max. operating temperature: 95 °C, Max. operating pressure: 3 bar, Electrical supply: 230 V AC, 50 Hz, 13 A fuse
Max. operating temperature: 95 °C, Max. operating pressure: 3 bar
D
NO
DK
FI
SWE
CZ
CH
ITA
FRA
ESP
BEL
LUX
NL
GB
IE
JAPAN
AUT
SLO
HUN
SK
UA
BG
GRE
NZL
Your local dealer:
AUSTRIAHargassner Ges.mbHA-4952 Weng, OÖ.Anton Hargassner Straße 1Telefon +43 (0) 77 23 / 52 74Fax +43 (0) 77 23 / 52 74-5office@hargassner.at
www.hargassner.at
GERMANYHargassner Ges.mbHD-84359 SimbachBachstraße 16Telefon +43 (0) 77 23 / 52 74Fax +43 (0) 77 23 / 52 74-5
03/1
5/ P
rintin
g er
rors
and
tech
nica
l cha
nges
rese
rved
D
NO
DK
FI
SWE
CZ
CH
ITA
FRA
ESP
BEL
LUX
NL
GB
IE
JAPAN
AUT
SLO
HUN
SK
UA
BG
GRE
NZL
D
NO
DK
FI
SWE
CZ
CH
ITA
FRA
ESP
BEL
LUX
NL
GB
IE
JAPAN
AUT
SLO
HUN
SK
UA
BG
GRE
NZL
Hargassner distribution partner
Japan
New Zealand
Hargassner-Location
International awards
Hargassner Products: Pellet Boilers, Wood Chip Boilers, Wood Log Boilers, Accumulators Industrial Boilers 150-200 kW, Multi-fuel Boilers, Containers, Wood Chip Transportation Systems. More information www.hargassner.com
New image videos: www.hargassner.com
S C H I C H T P U F F E R
H E I Z T E C H N I K M I T
H E I Z T E C H N I K M I T
H E I Z T E C H N I K M I T
www.hargassner.at
NEU
Schichtpuffer SPHygiene-Schichtpuffer HSPSolar Schichtpuffer SP-SW
Solar Hygiene-Schichtpuffer HSP-SW
S T Ü C K H O L Z - H E I Z U N G1/2m & 1m Vergaserkessel
1/3m Naturzugkessel
H E I Z T E C H N I K M I T
H E I Z T E C H N I K M I T
H E I Z T E C H N I K M I T
www.hargassner.at
NEU
www.hargassner.at
H A C K G U T - H E I Z U N GE C O - H K 2 0 - 6 0 K W
NEU
www.hargassner.at
NEUNEU
Gewinner des
Innovationspreis 2013des Bundesministeriums für Land-
und Forstwirtschaft, Umwelt und
Wasserwirtschaft und des Landes OÖ.
P E L L E T S - H E I Z U N G NANO-PK 6 / 9 / 12 KW
DIE KOMPAKTE HEIZZENTRALE
NEU
H E I Z T E C H N I K M I T
H E I Z T E C H N I K M I T
H E I Z T E C H N I K M I T
www.hargassner.
at
1st prize at the International Innovation competition for Wood Energy in France 2000, 2007, 2008, 2009, 2010, 2014 and 2015
Energy Genie 2007, 2013 and 2015 award at the Energy Saving Fair in Wels/Austria
2011 awarded with the AUSTRIAN ECO-LABEL 2011 and the Austrian economy prize PEGASUS in silver & gold 2011 & 2012
Best Business Award 2012, "Der Innviertler" in gold 2013
"Hidden Champion" 2014, "Grand Prix Biomass" 2014Awarded for an exemplary apprenticeship programme 2014