Panorama-Kamin57/25/85/25lifting door (easy-lift) State: 2018-02-06
Dimension sheets - Panorama-Kamin 57/25/85/25 lifting door (easy-lift)
State: 2018-02-06
… with fire table
Dimension sheets - Panorama-Kamin 57/25/85/25 lifting door (easy-lift)
State: 2018-02-06
… with fire table mounting frame
We suggest for CAD planing Palette CAD. Permanent updated drawings: www.brunner.deFrames / front versions are marked colored.
Planning and installation - Panorama-Kamin 57/25/85/25 lifting door (easy-lift)
Ulrich Brunner GmbHZellhuber Ring 17 - 18D-84307 EggenfeldernTelefonat: +49 / (0)87 21 / 7 71-0Telefax: +49 / (0)87 21 / 7 71-100info@brunner.de | www.brunner.de
BRUNNER Produkte werden ausschließlich vom qualifizierten Fachbetrieb angeboten und verkauft.Technische und Sortiments-Änderungen sowie Irrtum vorbehalten. State: 2018-02-06
Tested according to EN 13229 WValues measured at Rated capacitySuitable for all construction types according to rules OKEEI 108.7
Data for functional demonstrationRated heat power kW 13.5Fire wood volume kg/h 4.3Combustion performance kW 16Flue gas mass flow g/s 14Flue gas temperature after:
attached steel smoke hood °C 220Necessary supply pressure Pa 12Combustion air consumption m3/h 45Combustion air connection Ø mm 160
Heat distributionInsert / heat accumulator % 50 / -Glass pane (single / double) % 50 / -
Cross-section of gratings 1)
Convection air cm2 1000 / - / -Warm air cm2 1000 / - / -
Minimal oven surface for closed construction typeHeat dissipating surface m2 4.2
Minimal distances of the fireplaceto insulation layer cm 8to mounting floor cm 2
Thermal insulation without / with air gratings 2)
Mounting wall cm 16 / 12Floor cm 2 / 2Ceiling cm 25 / 18Brick lining for combustible wall cm 10
WeightFireplace / combustion chamber kg 220 / 68
Meets requirement/limit values for:Germany/ Austria / Suisse / Norway 1.BImSchV (Stufe 2) / 15a
BVG (2015) / LRV / NS 3059
1) for fireplace inserts / flue gas pipe / metallic reheating surface2) Values determined with upper air sections; stove cladding is heat emitting.