Post on 19-Mar-2020
SafEye™ Quasar 950/960Detection of toxic gases
The highly specialised open-path UV gas detection systems Quasar SafEye™ 950and 960 provide reliable gas leak monitoring: The Quasar 950 model detects thetoxic gases hydrogen sulphide and sulphur dioxide. The Quasar 960 model warnsof toxic ammonia.
D-3
8264-2
015
Cable gland
M25 / ¾ NPT
Receiver
Aligning mechanism
Mounting and swivel bracket
Measuring and reference sensors
Transmitter
Cable gland M25 /¾ NPT
Weather guard
Xenon lashing light
Manufactured by:
Benefits
02 | SafEye™ Quasar 950/960
As far as the SafEye™ can see
The fixed open path gas detectors of the SafEye™ Quasar 950 and SafEye™ Quasar 960 series protect bothyour staff and the high risk areas of your plant. The sensors in these detectors are distinguished by their highsensitivity and fast response time. With a range of up to 60 m (197 ft), they reliably measure the concentrationsof the toxic hazardous substances hydrogen sulphide (H2S) and sulphur dioxide (SO2) as well as ammonia(NH3).
Robust and resistant
You can rely on the SafEye™ Quasar 950/960 even in extreme and harsh conditions. The heated lensesprevent a reduction in the measuring performance due to ice build-up and snow accumulations. The detectoralso resists glare and is unaffected by sunlight, natural gas flares, welding arcs and other high intensityradiation. Even strong vibrations cannot harm it.
Complex, but not complicated
The SafEye™ Quasar 950/960 gas detector is a technically complex product – yet it is very easy to use. Itcan easily be installed, aligned, calibrated and configured by one person using the handheld unit (availableseparately).
Compatible with your control system
The SafEye™ Quasar 950/960 is equipped with different output signals. These are compatible with variousindustry-standard protocols such as 0 – 20 mA, HART® and RS485 Modbus. In addition, you can select theperfect model with the required range for your system from a wide selection of available versions. This givesyou greater flexibility in designing the customised security, monitoring and alarm system for your plant. Theapprovals for ATEX, IECEx, TR CU and SIL 2 for SafEye™ 950/960 are available.
Related Products
SafEye™ Quasar 950/960 | 03
ST-3
812-
2003
Dräger Polytron® 7000
The Dräger Polytron® 7000 is a gas detector that can satisfy manytoxic and oxygen gas measurement applications on a single platform. Itmeets the requirements of the compliance market as well as the highspecification requirements of customised solutions.
D-5
2604
-201
2
Dräger Polytron® 8100 EC
The Polytron® 8100 EC is Dräger’s top of the line explosion-prooftransmitter for the detection of toxic gases or oxygen. It uses a highperformance plug and play electrochemical DrägerSensor to detect aspecific gas. Besides having a 3-wire 4 to 20 mA analogue output withrelays, it also offers Modbus and Fieldbus protocol making it compatiblewith most control systems.
Technical Data
04 | SafEye™ Quasar 950/960
SafEye™ Quasar 950/960Type H2S, SO2 or NH3 Open Path Gas Detector
Measuring Range 0 – 500 ppm mResponse time T90 ≤10 sec.
Electrical DataSupply voltage 24 VDC nominal (18 – 32 VDC)Energy consumption Receiver: 150 mA (200 mA with heater on)
Transmitter: 200 mA (260 mA with heater on)Warm-up time 60 sec. for transmitter and receiverCable gland 2 x 3/4" – 14NPT conduit or 2 x M25 x 1.5 mm ISOElectrical input protection According to MIL–STD–1275BElectromagnetic compatibility EMI/RFI protected according to EN50270
OutputsOutput signal 0 – 20 mA; Gas reading 4 – 20 mAHART® Protocol HART® communication via the 0 – 20 mA analogue signal (FSK)RS-485 RS-485 Modbus compatible communicationVisual status indicator 3-colour LED: Green – operational, Yellow – fault, Red – alarm
Environmental conditionsTemperature -55 °C to 65 °C (-67 °F to 149 °F)Relative humidity Up to 95 % non-condensing (briefly withstands up to 100 % RH)
HousingTransmitter and receiver housing Stainless Steel 316L with electro polish
finishMaterial
Bracket Stainless steel 316LTransmitter and receiver housing 5 kg (11lb)WeightBracket 2 kg (4.2lb)Transmitter and receiver housing 267 x 130 x 130 mm (10.5" x 5.1" x 5.1")DimensionsBracket 120 x 120 x 158 mm (4.7" x 4.7" x 5.5")
Protection class IP66 and IP68 according to EN60529, NEMA 250 6P
ApprovalsATEX II 2G Ex db eb ib [ib Gb] IIB + H2 T4 Gb
II 2D Ex tb IIIC T135°C Db-55 °C ≤ Ta ≤ +65 °C
IECEx Ex db eb ib [ib Gb] IIB + H2 T4 GbEx tb IIIC T135°C Db-55 °C ≤ Ta ≤ +65 °C
TR CU (GOST R&K) 1Ex db eb ib [ib Gb] IIB + H2 T4 Gb XEx tb IIIC T135°C Db X-55 °C ≤ Ta ≤ +65 °C
SIL 2 according to IEC61508 (TUV)
Ordering Information
SafEye™ Quasar 950/960 | 05
Name Cable gland Dräger order number
SafEye™ 951/961 Tx(5 – 20 m)QTU-C-111
M25 68 13 490
SafEye™ 951/961 Tx(5 – 20 m)QTU-C-112
3/4" NPT 68 13 491
SafEye™ 952/962 Tx(15 – 40 m)QTU-C-211
M25 68 13 492
SafEye™ 952/962 Tx(15 – 40 m)QTU-C-212
3/4" NPT 68 13 493
SafEye™ 953/963 Tx(35 – 60 m)QTU-C-311
M25 68 13 494
SafEye™ 953/963 Tx(35 – 60 m)QTU-C-312
3/4" NPT 68 13 495
SafEye™ 950 (H2S) Rx
(5 – 60 m)QRU-C-111
M25 68 13 496
SafEye™ 950 (H2S) Rx
(5 – 60 m)QRU-C-112
3/4" NPT 68 13 497
SafEye™ 960 (NH3) Rx
(5 – 60 m)QRU-C-211
M25 68 13 498
SafEye™ 960 (NH3) Rx
(5 – 60 m)QRU-C-212
3/4" NPT 68 13 499
Tilt mount SafEye™ 9xx Series 68 13 501
Commissioning kit SafEye™ 950 (H2S) 68 13 502
Commissioning kit SafEye™ 960 (NH3) 68 13 503
HART® HHT diagnostic kit (Ex) 68 13 505
HART® HHT connection kit 68 13 506USB / RS485 converter kit, incl. SW 68 13 507SafEye™ 9xx connector cable (Non-Ex) 68 13 508Pole Mount (U-Bolt) 5" – (SS) 68 13 509SafEye™ Sunshade (SS) 68 13 510
Notes
06 | SafEye™ Quasar 950/960
Not all products, features, or services are for sale in all countries.Mentioned Trademarks are only registered in certain countries and not necessarily in the countryin which this material is released. Go to www.draeger.com/trademarks to find the current status.
CORPORATE HEADQUARTERSDrägerwerk AG & Co. KGaAMoislinger Allee 53–5523558 Lübeck, Germanywww.draeger.com
Manufacturer:Spectrex Inc.218 Little Falls RoadCedar Grove, NJ 07009USA
REGION DACHDräger Safety AG & Co. KGaARevalstraße 123560 Lübeck, GermanyTel +49 451 882 0Fax +49 451 882 2080info@draeger.com
REGION EUROPEDräger Safety AG & Co. KGaARevalstraße 123560 Lübeck, GermanyTel +49 451 882 0Fax +49 451 882 2080info@draeger.com
REGION MIDDLE EAST, AFRICADräger Safety AG & Co. KGaABranch OfficeP.O. Box 505108Dubai, United Arab EmiratesTel +971 4 4294 600Fax +971 4 4294 699contactuae@draeger.com
REGION ASIA PACIFICDraeger Singapore Pte. Ltd.25 International Business Park#04-20/21 German CentreSingapore 609916Tel +65 6308 9400Fax +65 6308 9401asia.pacific@draeger.com
REGION CENTRALAND SOUTH AMERICADraeger Panamá ComercialS. de R.L.59 East Street, Nuevo Paitilla,House 31, San Francisco TownPanama City, PanamaTel +507 377-9100 / Fax -9130servicioalcliente@draeger.com
REGION NORTH AMERICADraeger, Inc.3135 Quarry RoadTelford, PA 18969Tel +1 800 4DRAGER(+1 800 437 2437)Fax +1 215 723 5935info.usa@draeger.com
Locate your Regional SalesRepresentative at:www.draeger.com/contact
90 7
2 44
8 |
19.0
4-5
| H
Q |
PP
| S
ubje
ct to
mod
ifica
tions
| ©
201
9 D
räge
rwer
k AG
& C
o. K
GaA