Monitored using Geodetic Grids of length measurement interferometers Approx 800 Grid Line...

Post on 22-Dec-2015

222 views 2 download

Tags:

Transcript of Monitored using Geodetic Grids of length measurement interferometers Approx 800 Grid Line...

significant signal degradationin the presence of

measurements using FSIPrecise distance

P. A. Coe, A. Mitra, D. F. Howell & R. B. Nickerson

ATLAS Group Particle Physics University of Oxford

O verviewW hat is Frequency Scanning Interferom etry?

H ow is FS I used to m easure d istance?

W hat effects degrade the signals?

H ow can the effects be dealt w ith?

Outlook and future work.

W hy is FS I needed inside a partic le tracker?

emi onductor rackerS c T

ATLAS

Monitored using GeodeticGrids of length measurementinterferometers

Approx 800Grid Line Interferometers

Lasers

ReferenceI nterferom eters

SplitterTree

M ainD elivery

F ibre

Beam -S plitter

RadHard

Fibres

S CT S TRUCTURE

J ewel J ewelGLIPhotodetector

Retroreflector

To other GLI s

Interferometer design means returnsAre only -70 dB to -90 dB!

Reference Phase Measurem ent

Carre algorithm (110 steps)O

M odulate Long R eference Interferom eterusing PZT m ounted m irror

PZT voltage

PZT

12.5 m mDiam eter Mirror

LONG REFERENCE I NTERFEROMETER

25 m m Diam eter

Mirror

Non- polarising beam - splitter cube

PHOTODI ODEwith PI NHOLE

980 1000 1020 1040 1060 1080

-4

-3

-2

-1

0

1

2

3

4 E

xtr

act

ed

Ph

ase

/ r

ad

ian

s

Phase stepping cycle

(S ingle Laser)

Phase unwrapping

-800 -600

0

500

1000

1500

2000

2500

Inte

nsity

Laser Freq Shift / a .u.

To measure GLI phase shift…

(Reference phase)

How is sinusoidal fit chosen?

Minimise Fit Quality

SearchFor minimausing MINUIT

Think modulo 2

Signal degrading effects in ATLAS

• Low signals – 800 hungry interferometers to be fed

• Potential for reflections off many surfaces inside ATLAS

• Potential for mechanical vibrations (& turbulence)

Low signal power

Low signal power reduces depth of minimum in fit quality

In the presence of spurious reflections…

…other minimaappear

Measurement precision unaffected by spurious reflections

4 spuriousReflectors added

Vibration

More vibration….. Fit collapses!!

To Stop the Fit Collapsing

Redefine the WEIGHT inthe fit quality to penalise decreasein fringe amplitude

New WEIGHT = Fringe amplitude 1/2

Is there a problem at 400 nm = 0.5?or was it just because two subscans are not enough?

Increase peak to peak vibration amplitude to 1.8 m (>2)and use 6 subscans

At 70 Hz

Looks very promising…

CONCLUSIONS

• Initial investigations into the effects of low SNR, spurious reflections and vibrations show that…

• …FSI is a robust technique for precise distance measurements.

• Further work needed to improve linking and investigate data analysis alternatives and their potential benefits, eg FFT.