MODERN TRENDS OF FIRE PROTECTIONIN ROLLING STOCK
INTER-LABORATORY COMPARISON FOR EN 45545-2 TESTS
25 June 2014
1
• CERTIFER is a Notified Body (NoBo) to the European Community for the interoperability of the rail system
• CERTIFER is also an Designed Body (OQA-De Bo) to evaluate the design and implementation of systems or sub-systems new or substantially modified rail
• In 2006 , SNCF and RATP has transferred to CERTIFER the accreditation of the laboratories for I-F classification ( NF F16-101)
• From 2007, CERTIFER has introduced inter-laboratory comparison for EN 45545 tests• Inter-laboratory is a tool of selection of
laboratories in addition to the accreditation ISO/CEI 17025
2PROGRESS OF INTER-LABORATORY CAMPAIGNS
•An Assessment Team composed with experts from laboratories and railway operators who were involved in the drafting of EN 45545•The statistical analysis is realized according to ISO 5725
1. Determination of average and standard deviation for the different laboratories
2. 2σ preliminary test: each extreme value must be included in less than 2 Standard deviations (2σ) above or below the average of other laboratories, if not the value is excluded
3. Search of aberrant value according to IS0 5725 with Mandel test. Determination of the repeatability and reproducibility
4. Send Deviation Form to the laboratories who are excluded by 2σ or aberrant value
5. Analysis of the answer of the laboratories and exchange6. Publication of a list of recognized laboratories
Laboratories involved in 200716 in 8 country
• BODYCOTE WARRINGTON FIRE
• BRE• QinetiQ
• AEF• CREPIM• LCPP• LNE• RATP• RESCOLL
• LAPI• LSF
• CURRENTA (BAYER)
• VTT
• CNTK
• SINTEF
• SP
3
Laboratories involved in period 2008-201333 in14 country
• EXOVA (WARRINGTON FIRE)• BRE• QINETIQ
• AEF• CREPIM• IFTH• LCPP• LNE• RATP• RESCOLL• HERAKLES(SNPE)• STRATIFORME
• CSI• LAPI• LSF• TECNALIA
• BASF• CURRENTA (BAYER)• RST
• VTT
• IK (CNTK)• KTZO• SYCHTA
• SINTEF
• SP
• CENTEXBEL
• AITEX• GAIKER
• OFI• TGM• LANTAL
• DBI
• SGS-CSTC
4
INTER-LABORATORY 2014
Five new laboratories involved
- JECTEC (Japan)- Deutsche Bahn (Germany)- DMT (Germany)- TUDOR (Luxembourg)- GIORDANO (Italy)
5
EN 45545-2 Tests Parameter Requirements Inter-Laboratory
EN ISO 4589-2 OI R22, R23, R24 X
ISO 5658-2 CFE R1to R4, R7R11, R12, R17
X
ISO 5660-1 MAHRE R1 to R3, R5 to R12, R17 to R21
X
EN ISO 9239-1 CHF R8, R10 X
EN ISO 11925-2 30 s flame application R4, R5
EN 12952-2 Time Burning R20
ISO TR 9705/2 MAHRE R18
EN 60332..,50305.. Height of chared zone R15, R16
EN ISO 5659-2 Ds4, VOF4, Dsmax R1 to R3, R5 to R12, R17, R20 to R23
X
EN 45545 Annexe C CITGR1 to R12, R17, R20, R21
X
NF X 70-100 CITNLP R22, R23 X(1)
EN 60695-2-11 Temperature R25
EN 60695-11-10 Flame R26
6
(1) Results of French Inter-laboratory campaign without NO and NOx
7
Few laboratories excluded by 2σ and aberrant value
Results without correction
2σAberrant
Good reproducibility
8Results after Deviation Form
9
HL2
HL3
HL1
Minor exclusion by 2σ and aberrant value
Results without correction
2σAberrant
10
Good reproducibility
HL3
Results after Deviation Form
11
A lot of dispertion for materials with high fire property
NC
HL
Results without correction
Aberrant
2σ
12
Good reproducibility for materials with flame propagation
NC
HL
Results after Deviation Form
13
Large range of value with aberrant value
HL3
HL2
Results without correction
2σ
14
Variable reproducibility according the materials
HL3
HL2
Results after Deviation Form
15
Large range of value for Polyamide carpet
HL2/HL3
NC
Results without correction
2σ
16
Not enough campaign for judgement but seems identical to 50 kW/m2
HL2/HL3
NC
Results after Deviation Form
17
Few aberrant value
HL3
Results without correction
2σ
18
Good reproducibility
HL3
Results after Deviation Form
19
Few exclusion by 2σ and aberrant value
HL3
HL1
2σAberrant
20
Good reproducibility
HL3
HL1
Results after Deviation Form
21
Large range of value (But only two campaign)
HL3
HL2
2σ
22
Large range of value for some materials
23
Identical to CO
24
Large range of value for some materials
25
HBr was only expected for GRP
26
HCl was only expected for GRP
27
Large range of value for some materials
28
SO2 was not expected for GRP /Large range of value for wool carpet
29
Large range of value (but far from the limit of the standard)
30
Identical to 4 min
Grouped results for some materials
31Results after Deviation Form
Less divergence for NF X70-100
32COMPARISON CIT NF X70-100/EN 45545
EN 45545-2 tests Parameter Reproducibilty Commentary
EN ISO 4589-2 OI **** Robust test
EN ISO 9239-1 CHF **** Robust test
ISO 5658-2 CFE ** Limit in the standard at 13 and 20 kW/m2 will minimize the consequence
ISO 5660-1 MAHRE **Can reject some materials at the limit of
the classification
EN ISO 5659-2 Ds4VOF4 ****
Robust test
EN ISO 5659-2 Dsmax ***Depends if inflammation or not
EN 45545 Annexe C CIT G **Will no affect the classification of
materials. Very few materials will be rejected (ex: PVC)
NF X 70-100 CIT NLP ***Long experience of laboratories
33CONCLUSION
34