The 007-IFC now includes an Integral Flow Check, saving installation costs while improving system performance.The patented IFC replaces a separate in-line flow check and prevents gravity flow when the heating zone is notoperating. The 007-Z-IFC adds the IFC feature to our Priority Zoning circulator with built-in transformer relay,and priority switch to make it the best choice when zoning with circulators.
Model 007-IFC™ Cartridge Circulator
Effective Date: 09/1/03Printed in USA
©Taco Catalog # : 100-6.9Supersedes: 100-6.9 Dated 10/1/02
Water CirculationPumps & Circulators
HYDRONIC COMPONENTS & SYSTEMS
Submittal Data InformationModel 007-IFC™ Cartridge Circulator
Submittal Data # 101-077Supersedes: 10/1/02
Effective: 09/1/03
ApplicationThe 007-IFC with an Integral Flow Check is designed to reduce installation costs when zoning with“00” circulators on Hydronic or Radiant heating, Hydro-Air Fan Coils or Indirect water heaters.By locating the patented IFC inside the pump casing, a separate in-line flow check is eliminated,reducing installation costs. The reduced pressure drop of the IFC, increases the 007 flow performanceup to 240% over in-line check valves. Both the IFC and cartridge are easily accessed for serviceinstead of replacing the entire unit. The 007-Z-IFC combines the circulator, flow-check and patentedPriority Zoning control with built-in transformer, relay and priority switch in one complete, compactpackage to make it ideal for zoning. Available in Cast Iron construction with flanged connections.
Performance Field - 60Hz
Features• Integral Flow Check (IFC) Patent# 5,664,939
Prevents gravity flowEliminates separate in-line flow checkReduces installed cost, easy to serviceImproved performance vs. In-line flowchecks
• Unique replaceable cartridge-Field serviceable• Unmatched reliability-Maintenance free• Quiet, efficient operation• Direct drive-Low power consumption• Self lubricating, No mechanical seal• Standard high capacity output-Compact design• Wide range of applications• Cast Iron construction, Flanged connections
Materials of ConstructionCasing (Volute): Cast Iron Integral Flow Check:
Body, Plunger....AcetalO-ring Seals......NitrileSpring.................Stainless Steel
Stator Housing: SteelCartridge: Stainless SteelImpeller: Non-MetallicShaft: CeramicBearings: CarbonO-Ring & Gaskets: EPDM
Model NomenclatureF – Cast Iron, FlangedIFC – Integral Flow CheckVariations:Z – Zoning CirculatorJ – Bronze Cartridge with Cast Iron Casing
Performance Data Flow Range: 0 - 12.5 GPMHead Range: 0 - 11 FeetMinimum Fluid Temperature: 40˚F (4˚C) Maximum Fluid Temperature: 240°F (115˚C)Maximum Working Pressure: 125 psiConnection Sizes: 3/4”, 1”, 1-1/4”, 1-1/2” Flanged
FOR INDOOR USE ONLY
A B C D E F Ship Wt.Model Casing in. mm in. mm in. mm in. mm in. mm in. mm lbs. Kg007-F5-IFC Cast Iron 7 178 4-1/2 114 3-3/16 81 2-15/16 75 5 127 6-3/8 162 9 4.0
007-ZF5-IFC Cast Iron 7 178 4-1/2 114 3-3/16 81 3-5/8 92 5-9/16 143 6-3/8 162 9 4.0
Pump Dimensions & Weights
Model Volts Hz Ph Amps RPM HP007-F5-IFC 115 60 1 .71 3250 1/25007-ZF5-IFC 115 60 1 .71 3250 1/25Motor Permanent Split CapacitorType Impedance ProtectedMotor Options 220/50/1, 220/60/1, 230/60/1, 100/110/50/60/1
Electrical Data